Tracked Changes. Electromagnetic compatibility (EMC) – Limits. Limits for harmonic current emissions (equipment input current ≤16 A per phase)
Published By | Publication Date | Number of Pages |
BSI | 2019 | 91 |
IEC 61000-3-2:2018 is also available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low?voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and can be subject to installation restrictions as indicated in IEC 61000-3-12. The tests according to this document are type tests. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) an update of the emission limits for lighting equipment with a rated power ? 25 W to take into account new types of lighting equipment; b) the addition of a threshold of 5 W under which no emission limits apply to all lighting equipment; c) the modification of the requirements applying to the dimmers when operating non?incandescent lamps; d) the addition of test conditions for digital load side transmission control devices; e) the removal of the use of reference lamps and reference ballasts for the tests of lighting equipment; f) the simplification and clarification of the terminology used for lighting equipment; g) the classification of professional luminaires for stage lighting and studios under Class A; h) a clarification about the classification of emergency lighting equipment; i) a clarification for lighting equipment including one control module with an active input power ? 2 W; j) an update of the test conditions for television receivers; k) an update of the test conditions for induction hobs, taking also into account the other types of cooking appliances; l) for consistency with IEC 61000-3-12, a change of the scope of IEC 61000-3-2 from equipment with an input current ? 16 A to equipment with a rated input current ? 16 A. Keywords: harmonic currents
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | compares BS EN IEC 61000-3-2:2019 |
2 | TRACKED CHANGES Test example 1 |
3 | BS EN IEC 61000-3-2:2019 to BS EN 61000-3-2:2014 |
5 | BS EN IEC 61000‑3‑2:20142019 BRITISH STANDARD Compliance with a British Standard cannot confer immunity from legal obligations. Amendments/corrigenda issued since publication |
7 | Endorsement notice |
10 | This page deliberately left blank |
11 | Annex ZZ (informative) Coverage of Essential Requirements of EU Directives |
14 | INTERNATIONAL ELECTROTECHNICAL COMMISSION FOREWORD |
15 | IMPORTANT – The ‘colour inside’ logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour pr… |
16 | INTRODUCTION Part 1: General Part 2: Environment Part 3: Limits Part 4: Testing and measurement techniques Part 5: Installation and mitigation guidelines Part 6: Generic standards Part 9: Miscellaneous |
17 | ELECTROMAGNETIC COMPATIBILITY (EMC) – 1 Scope 2 Normative references |
18 | 3 Terms and definitions 3.1 3.2 3.3 |
19 | 3.4 3.5 3.6 3.7 3.8 3.93.5 input current 3.103.6 3.113.7 3.123.8 3.133.9 |
20 | 3.14 THC 3.14.23.11 total harmonic distortion THD 3.15 built-in dimmer 3.163.12 POHC 3.173.13 |
21 | 3.183.14 3.193.15 3.203.16 3.213.17 |
22 | 3.223.18 3.19 3.20 3.21 3.22 built-in dimmer 3.23 3.24 |
23 | 3.25 3.26 4 General 5 Classification of equipment 5.1 General |
24 | 5.2 Description of lighting equipment 6 General requirements 6.1 General |
25 | 6.16.2 Control methods 6.26.3 Harmonic current measurement 6.2.16.3.1 Test configuration |
26 | 6.2.26.3.2 Measurement procedure 6.2.36.3.3 General requirements |
27 | 6.2.3.26.3.3.2 Reproducibility 6.2.3.36.3.3.3 Starting and stopping 6.2.3.46.3.3.4 Application of limits |
28 | 6.2.3.56.3.3.5 Test report 6.2.46.3.4 Test observation period 6.36.4 Equipment in a rack or case 7 Harmonic current limits 7.1 General |
30 | Figure 1 – Flowchart for determining conformity 7.17.2 Limits for Class A equipment 7.27.3 Limits for Class B equipment |
31 | 7.37.4 Limits for Class C equipment a) Active input power > 25 W 7.4.1 General 7.4.2 Rated power > 25 W |
32 | 7.4.3 Rated power ≥ 5 W and ≤ 25 W 7.47.5 Limits for Class D equipment |
33 | Table 1 – Limits for Class A equipment Table 3 – Limits for Class D equipment |
35 | Annex A (normative) A.1 Test circuit A.2 Supply source |
37 | Figure A.2 – Measurement circuit for three-phase equipment |
38 | Annex B |
39 | Annex CB (normative) C.1B.1 General C.2B.2 Test conditions for television (TV) receivers (TV) C.2.1B.2.1 General conditionsrequirements B.2.2 Measurement conditions B.2.2.2 Image level adjustments B.2.2.3 Sound level adjustments B.2.2.4 Energy-saving function B.2.3 Test report C.2.2 Conditions for measurement |
40 | C.3B.3 Test conditions for audio amplifiers C.3.1B.3.1 Conditions C.3.2B.3.2 Input signals and loads |
41 | C.4B.4 Test conditions for video-cassette recorders C.5B.5 Test conditions for lighting equipment C.5.1B.5.1 General conditions C.5.2B.5.2 Lamps C.5.3B.5.3 Luminaires |
42 | C.5.4 Ballasts and step-down converters B.5.4 Lighting control gear B.5.5 DLT control devices C.6B.6 Test conditions for independent and built-in incandescent lamp phase control dimmers for lighting equipment C.7B.7 Test conditions for vacuum cleaners |
43 | C.8B.8 Test conditions for washing machines C.9B.9 Test conditions for microwave ovens C.10B.10 Test conditions for information technology equipment (ITE) C.10.1B.10.1 General conditions |
44 | C.10.2B.10.2 Optional conditions for measuring emissions of IT equipment with external power supplies or battery chargers C.11B.11 Test conditions for induction hobscooking appliances B.11.1 Induction hobs and hotplates |
45 | B.11.2 Hobs and hotplates other than induction cooking appliances C.12B.12 Test conditions for air conditioners |
46 | C.13B.13 Test conditions for kitchen machines as defined in IEC 60335-2-14 C.14B.14 Test conditions for arc welding equipment which is not professional equipment Table C.1B.1 – Conventional load for arc welding equipment tests C.16B.16 Test conditions for refrigerators and freezers C.16.1B.16.1 General |
47 | C.16.2B.16.2 Refrigerators and freezers with VSD C.16.3B.16.3 Refrigerators and freezers without VSD |
48 | Bibliography |
49 | This page deliberately left blank |
51 | undefined |
54 | Annex ZA(normative)Normative references to international publicationswith their corresponding European publications |
56 | English CONTENTS |
58 | FOREWORD |
60 | INTRODUCTION |
61 | 1 Scope 2 Normative references |
62 | 3 Terms and definitions |
65 | 4 General |
66 | 5 Classification of equipment 5.1 General 5.2 Description of lighting equipment |
67 | 6 General requirements 6.1 General 6.2 Control methods |
68 | 6.3 Harmonic current measurement 6.3.1 Test configuration |
69 | 6.3.2 Measurement procedure 6.3.3 General requirements |
71 | 6.3.4 Test observation period 6.4 Equipment in a rack or case 7 Harmonic current limits 7.1 General |
72 | 7.2 Limits for Class A equipment Figures Figure 1 – Flowchart for determining conformity |
73 | 7.3 Limits for Class B equipment 7.4 Limits for Class C equipment 7.4.1 General 7.4.2 Rated power > 25 W |
74 | 7.4.3 Rated power ≥ 5 W and ≤ 25 W Figure 2 – Illustration of the relative phase angle and current parameters described in 7.4.3 |
75 | 7.5 Limits for Class D equipment Tables Table 1 – Limits for Class A equipment Table 2 – Limits for Class C equipment a |
76 | Table 3 – Limits for Class D equipment Table 4 – Test observation period |
77 | Annex A (normative) Measurement circuit and supply source A.1 Test circuit A.2 Supply source |
78 | Figure A.1 – Measurement circuit for single-phase equipment |
79 | Figure A.2 – Measurement circuit for three-phase equipment |
80 | Annex B (normative) Type test conditions B.1 General B.2 Test conditions for television receivers (TV) B.2.1 General requirements B.2.2 Measurement conditions |
81 | B.2.3 Test report B.3 Test conditions for audio amplifiers B.3.1 Conditions B.3.2 Input signals and loads |
82 | B.4 Test conditions for video-cassette recorders B.5 Test conditions for lighting equipment B.5.1 General conditions B.5.2 Lamps B.5.3 Luminaires B.5.4 Lighting control gear |
83 | B.5.5 DLT control devices B.6 Test conditions for independent phase control dimmers for lighting equipment B.7 Test conditions for vacuum cleaners B.8 Test conditions for washing machines |
84 | B.9 Test conditions for microwave ovens B.10 Test conditions for information technology equipment (ITE) B.10.1 General conditions |
85 | B.10.2 Optional conditions for measuring emissions of IT equipment with external power supplies or battery chargers B.11 Test conditions for cooking appliances B.11.1 Induction hobs and hotplates |
86 | B.11.2 Hobs and hotplates other than induction cooking appliances B.12 Test conditions for air conditioners B.13 Test conditions for kitchen machines as defined in IEC 60335-2-14 B.14 Test conditions for arc welding equipment which is not professional equipment |
87 | B.15 Test conditions for high pressure cleaners which are not professional equipment B.16 Test conditions for refrigerators and freezers B.16.1 General B.16.2 Refrigerators and freezers with VSD Table B.1 – Conventional load for arc welding equipment tests |
88 | B.16.3 Refrigerators and freezers without VSD |
89 | Bibliography |