Tracked Changes. Electromagnetic compatibility (EMC) – Limits. Limits for harmonic current emissions (equipment input current ≤16 A per phase)

Published By Publication Date Number of Pages
BSI 2019 91
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 61000-3-2:2018 is also available as /2 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public low?voltage distribution systems. Arc welding equipment which is not professional equipment, with a rated input current up to and including 16 A per phase, is included in this document. Arc welding equipment intended for professional use, as specified in IEC 60974-1, is excluded from this document and can be subject to installation restrictions as indicated in IEC 61000-3-12. The tests according to this document are type tests. For systems with nominal voltages less than but not equal to 220 V (line-to-neutral), the limits have not yet been considered. This fifth edition cancels and replaces the fourth edition published in 2014. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) an update of the emission limits for lighting equipment with a rated power ? 25 W to take into account new types of lighting equipment; b) the addition of a threshold of 5 W under which no emission limits apply to all lighting equipment; c) the modification of the requirements applying to the dimmers when operating non?incandescent lamps; d) the addition of test conditions for digital load side transmission control devices; e) the removal of the use of reference lamps and reference ballasts for the tests of lighting equipment; f) the simplification and clarification of the terminology used for lighting equipment; g) the classification of professional luminaires for stage lighting and studios under Class A; h) a clarification about the classification of emergency lighting equipment; i) a clarification for lighting equipment including one control module with an active input power ? 2 W; j) an update of the test conditions for television receivers; k) an update of the test conditions for induction hobs, taking also into account the other types of cooking appliances; l) for consistency with IEC 61000-3-12, a change of the scope of IEC 61000-3-2 from equipment with an input current ? 16 A to equipment with a rated input current ? 16 A. Keywords: harmonic currents

PDF Catalog

PDF Pages PDF Title
1 compares BS EN IEC 61000-3-2:2019
2 TRACKED CHANGES
Test example 1
3 BS EN IEC 61000-3-2:2019 to BS EN 61000-3-2:2014
5 BS EN IEC 61000‑3‑2:20142019 BRITISH STANDARD
Compliance with a British Standard cannot confer immunity from legal obligations.
Amendments/corrigenda issued since publication
7 Endorsement notice
10 This page deliberately left blank
11 Annex ZZ
(informative)
Coverage of Essential Requirements of EU Directives
14 INTERNATIONAL ELECTROTECHNICAL COMMISSION
FOREWORD
15 IMPORTANT – The ‘colour inside’ logo on the cover page of this publication indicates that it contains colours which are considered to be useful for the correct understanding of its contents. Users should therefore print this document using a colour pr…
16 INTRODUCTION
Part 1: General
Part 2: Environment
Part 3: Limits
Part 4: Testing and measurement techniques
Part 5: Installation and mitigation guidelines
Part 6: Generic standards Part 9: Miscellaneous
17 ELECTROMAGNETIC COMPATIBILITY (EMC) –
1 Scope
2 Normative references
18 3 Terms and definitions
3.1
3.2
3.3
19 3.4
3.5
3.6
3.7
3.8
3.93.5
input current
3.103.6
3.113.7
3.123.8
3.133.9
20 3.14
THC
3.14.23.11
total harmonic distortion
THD
3.15
built-in dimmer
3.163.12
POHC
3.173.13
21 3.183.14
3.193.15
3.203.16
3.213.17
22 3.223.18
3.19
3.20
3.21
3.22
built-in dimmer
3.23
3.24
23 3.25
3.26
4 General
5 Classification of equipment
5.1 General
24 5.2 Description of lighting equipment
6 General requirements
6.1 General
25 6.16.2 Control methods
6.26.3 Harmonic current measurement
6.2.16.3.1 Test configuration
26 6.2.26.3.2 Measurement procedure
6.2.36.3.3 General requirements
27 6.2.3.26.3.3.2 Reproducibility
6.2.3.36.3.3.3 Starting and stopping
6.2.3.46.3.3.4 Application of limits
28 6.2.3.56.3.3.5 Test report
6.2.46.3.4 Test observation period
6.36.4 Equipment in a rack or case
7 Harmonic current limits
7.1 General
30 Figure 1 – Flowchart for determining conformity
7.17.2 Limits for Class A equipment
7.27.3 Limits for Class B equipment
31 7.37.4 Limits for Class C equipment
a) Active input power > 25 W
7.4.1 General
7.4.2 Rated power > 25 W
32 7.4.3 Rated power ≥ 5 W and ≤ 25 W
7.47.5 Limits for Class D equipment
33 Table 1 – Limits for Class A equipment
Table 3 – Limits for Class D equipment
35 Annex A
(normative)
A.1 Test circuit
A.2 Supply source
37 Figure A.2 – Measurement circuit for three-phase equipment
38 Annex B
39 Annex CB
(normative)
C.1B.1 General
C.2B.2 Test conditions for television (TV) receivers (TV)
C.2.1B.2.1 General conditionsrequirements
B.2.2 Measurement conditions
B.2.2.2 Image level adjustments
B.2.2.3 Sound level adjustments
B.2.2.4 Energy-saving function
B.2.3 Test report
C.2.2 Conditions for measurement
40 C.3B.3 Test conditions for audio amplifiers
C.3.1B.3.1 Conditions
C.3.2B.3.2 Input signals and loads
41 C.4B.4 Test conditions for video-cassette recorders
C.5B.5 Test conditions for lighting equipment
C.5.1B.5.1 General conditions
C.5.2B.5.2 Lamps
C.5.3B.5.3 Luminaires
42 C.5.4 Ballasts and step-down converters
B.5.4 Lighting control gear
B.5.5 DLT control devices
C.6B.6 Test conditions for independent and built-in incandescent lamp phase control dimmers for lighting equipment
C.7B.7 Test conditions for vacuum cleaners
43 C.8B.8 Test conditions for washing machines
C.9B.9 Test conditions for microwave ovens
C.10B.10 Test conditions for information technology equipment (ITE)
C.10.1B.10.1 General conditions
44 C.10.2B.10.2 Optional conditions for measuring emissions of IT equipment with external power supplies or battery chargers
C.11B.11 Test conditions for induction hobscooking appliances
B.11.1 Induction hobs and hotplates
45 B.11.2 Hobs and hotplates other than induction cooking appliances
C.12B.12 Test conditions for air conditioners
46 C.13B.13 Test conditions for kitchen machines as defined in IEC 60335-2-14
C.14B.14 Test conditions for arc welding equipment which is not professional equipment
Table C.1B.1 – Conventional load for arc welding equipment tests
C.16B.16 Test conditions for refrigerators and freezers
C.16.1B.16.1 General
47 C.16.2B.16.2 Refrigerators and freezers with VSD
C.16.3B.16.3 Refrigerators and freezers without VSD
48 Bibliography
49 This page deliberately left blank
51 undefined
54 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
56 English
CONTENTS
58 FOREWORD
60 INTRODUCTION
61 1 Scope
2 Normative references
62 3 Terms and definitions
65 4 General
66 5 Classification of equipment
5.1 General
5.2 Description of lighting equipment
67 6 General requirements
6.1 General
6.2 Control methods
68 6.3 Harmonic current measurement
6.3.1 Test configuration
69 6.3.2 Measurement procedure
6.3.3 General requirements
71 6.3.4 Test observation period
6.4 Equipment in a rack or case
7 Harmonic current limits
7.1 General
72 7.2 Limits for Class A equipment
Figures
Figure 1 – Flowchart for determining conformity
73 7.3 Limits for Class B equipment
7.4 Limits for Class C equipment
7.4.1 General
7.4.2 Rated power > 25 W
74 7.4.3 Rated power ≥ 5 W and ≤ 25 W
Figure 2 – Illustration of the relative phase angle and current parameters described in 7.4.3
75 7.5 Limits for Class D equipment
Tables
Table 1 – Limits for Class A equipment
Table 2 – Limits for Class C equipment a
76 Table 3 – Limits for Class D equipment
Table 4 – Test observation period
77 Annex A (normative) Measurement circuit and supply source
A.1 Test circuit
A.2 Supply source
78 Figure A.1 – Measurement circuit for single-phase equipment
79 Figure A.2 – Measurement circuit for three-phase equipment
80 Annex B (normative) Type test conditions
B.1 General
B.2 Test conditions for television receivers (TV)
B.2.1 General requirements
B.2.2 Measurement conditions
81 B.2.3 Test report
B.3 Test conditions for audio amplifiers
B.3.1 Conditions
B.3.2 Input signals and loads
82 B.4 Test conditions for video-cassette recorders
B.5 Test conditions for lighting equipment
B.5.1 General conditions
B.5.2 Lamps
B.5.3 Luminaires
B.5.4 Lighting control gear
83 B.5.5 DLT control devices
B.6 Test conditions for independent phase control dimmers for lighting equipment
B.7 Test conditions for vacuum cleaners
B.8 Test conditions for washing machines
84 B.9 Test conditions for microwave ovens
B.10 Test conditions for information technology equipment (ITE)
B.10.1 General conditions
85 B.10.2 Optional conditions for measuring emissions of IT equipment with external power supplies or battery chargers
B.11 Test conditions for cooking appliances
B.11.1 Induction hobs and hotplates
86 B.11.2 Hobs and hotplates other than induction cooking appliances
B.12 Test conditions for air conditioners
B.13 Test conditions for kitchen machines as defined in IEC 60335-2-14
B.14 Test conditions for arc welding equipment which is not professional equipment
87 B.15 Test conditions for high pressure cleaners which are not professional equipment
B.16 Test conditions for refrigerators and freezers
B.16.1 General
B.16.2 Refrigerators and freezers with VSD
Table B.1 – Conventional load for arc welding equipment tests
88 B.16.3 Refrigerators and freezers without VSD
89 Bibliography
BS EN IEC 61000-3-2:2019 - TC