Fibre optic interconnecting devices and passive components. Basic test and measurement procedures – General and guidance

Published By Publication Date Number of Pages
BSI 2022 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 61300 provides general information and guidance for the basic test and measurement procedures defined in the IEC 61300-2 series and IEC 61300-3 series for interconnecting devices, passive components, mechanical splices, fusion splice protectors, fibre management systems and protective housings. This standard is used in combination with the relevant specification which defines the tests to be used, the required degree of severity for each of them, their sequence, if relevant, and the permissible performance limits. In the event of conflict between this basic standard and the relevant specification, the latter takes precedence.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
7 English
CONTENTS
9 FOREWORD
11 INTRODUCTION
12 1 Scope
2 Normative references
13 3 Terms, definitions and abbreviated terms
3.1 Terms and definitions
16 3.2 Abbreviated terms
4 Requirements for IEC 61300-2 (all parts) and IEC 61300-3 (all parts)
4.1 Requirements for IEC 61300-2 (all parts) (tests)
4.2 Requirements for IEC 61300-3 (all parts) (examinations and measurement procedures)
4.2.1 General requirements
4.2.2 Requirements for attenuation variation
17 5 Standard atmospheric conditions
6 Significance of the numerical value of a quantity
6.1 General
6.2 Quantity expressed as nominal value with tolerance
Tables
Table 1 – Standard atmospheric conditions
18 6.3 Quantity expressed as a range of values
7 Graphical symbols and terminology
19 8 Safety
9 Calibration
9.1 General
9.2 Round robin calibration procedure
10 Launch conditions
10.1 General
20 10.2 Multimode launch conditions for A1 fibres
10.3 Multimode launch conditions for A3e fibre
Table 2 – Expected variation of attenuation due to mode variation of single connections for A1-OM2, A1-OM3, A1-OM4 and A1-OM5 fibres
21 10.4 Multimode launch conditions for the other multimode fibres
10.5 Single-mode launch conditions
10.6 Multimode planar waveguide launch conditions
Table 3 – Expected variation of attenuation due to mode variation of single connections for A3e fibre
22 Annex A (normative) Multimode launch condition requirement for measuring attenuation of components terminated on IEC 60793-2-10 type A1 fibres
23 Figures
Figure A.1 – Encircled flux template example
Table A.1 – EF requirements for 50 µm core fibre at 850 nm
24 Table A.2 – EF requirements for 50 µm core fibre at 1 300 nm
Table A.3 – EF requirements for 62,5 µm fibre at 850 nm
Table A.4 – EF requirements for 62,5 µm fibre at 1 300 nm
25 Annex B (normative) Multimode launch condition requirement for measuring attenuation of components terminated on IEC 60793-2-30 type A3e fibres
Figure B.1 – Encircled angular flux template example
26 Table B.1 – EAF requirements for NA of 0,37 and 200 µm core fibre at 850 nm
27 Bibliography