BS EN IEC 62053-23:2021+A11:2021

$142.49

Electricity metering equipment. Particular requirements – Static meters for reactive energy (classes 2 and 3)

Published By Publication Date Number of Pages
BSI 2021 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This part of IEC 62053 applies only to static var-hour meters of accuracy classes 2 and 3 for the measurement of alternating current electrical reactive energy in 50 Hz or 60 Hz networks and it applies to their type tests only.

For practical reasons, this document is based on a conventional definition of reactive energy for sinusoidal currents and voltages containing the fundamental frequency only.

NOTE 1 For other general requirements, such as safety, dependability, etc., see the relevant IEC 62052 or IEC 62059 standards.

This document applies to electricity metering equipment designed to:

  • measure and control electrical energy on electrical networks (mains) with voltage up to 1 000 V;

NOTE 2 For AC electricity meters, the voltage mentioned above is the line-to-neutral voltage derived from nominal voltages. See IEC 62052-31:2015, Table 7.

  • have all functional elements, including add-on modules, enclosed in, or forming a single meter case with exception of indicating displays;

  • operate with integrated or detached indicating displays, or without an indicating display;

  • be installed in a specified matching socket or rack;

  • optionally, provide additional functions other than those for measurement of electrical energy.

Meters designed for operation with low power instrument transformers (LPITs as defined in the IEC 61869 series) may be considered as compliant with this document only if such meters and their LPITs are tested together and meet the requirements for directly connected meters.

NOTE 3 Modern electricity meters typically contain additional functions such as measurement of voltage magnitude, current magnitude, power, frequency, power factor, etc.; measurement of power quality parameters; load control functions; delivery, time, test, accounting, recording functions; data communication interfaces and associated data security functions. The relevant standards for these functions may apply in addition to the requirements of this document. However, the requirements for such functions are outside the scope of this document.

NOTE 4 Product requirements for power metering and monitoring devices (PMDs) and measurement functions such as voltage magnitude, current magnitude, power, frequency, etc., are covered in IEC 61557-12. However, devices compliant with IEC 61557-12 are not intended to be used as billing meters unless they are also compliant with IEC 62052-11:2020 and one or more relevant IEC 62053-xx accuracy class standards.

NOTE 5 Product requirements for power quality instruments (PQIs) are covered in IEC 62586-1. Requirements for power quality measurement techniques (functions) are covered in IEC 61000-4-30. Requirements for testing of the power quality measurement functions are covered in IEC 62586-2.

This document does not apply to:

  • meters for which the voltage line-to-neutral derived from nominal voltages exceeds 1 000 V;

  • meters intended for connection with low power instrument transformers (LPITs as defined in the IEC 61869 series) when tested without such transformers;

  • metering systems comprising multiple devices (except LPITs) physically remote from one another;

  • portable meters;

NOTE 6 Portable meters are meters that are not permanently connected.

  • meters used in rolling stock, vehicles, ships and airplanes;

  • laboratory and meter test equipment;

  • reference standard meters;

  • data interfaces to the register of the meter;

  • matching sockets or racks used for installation of electricity metering equipment;

  • any additional functions provided in electrical energy meters.

This document does not cover measures for the detection and prevention of fraudulent attempts to compromise a meter’s performance (tampering).

NOTE 7 Nevertheless, specific tampering detection and prevention requirements, and test methods, as relevant for a particular market are subject to the agreement between the manufacturer and the purchaser.

NOTE 8 Specifying requirements and test methods for fraud detection and prevention would be counterproductive, as such specifications would provide guidance for potential fraudsters.

NOTE 9 There are many types of meter tampering reported from various markets; therefore, designing meters to detect and prevent all types of tampering could lead to unjustified increase in costs of meter design, verification and validation.

NOTE 10 Billing systems, such as, smart metering systems, are capable of detecting irregular consumption patterns and irregular network losses which enable discovery of suspected meter tampering.

NOTE 11 For transformer operated meters paired with current transformers (CTs) according to IEC 61869-2:

  • the standard CT measuring range is specified from 0,05 In to Imax for accuracy classes 0,1, 0,2, 0,5 and 1 and these CTs are used for meters of class 2 and 3 according to this document;

  • the special CT measuring range is specified from 0,01 In to I max for accuracy classes 0,2S and 0,5 S and these CTs are used for meters of class 0,5 S and 1 S according to IEC 62053-24;

  • combinations of standard CTs and meters of class 0,5 S and 1 S are subject to an agreement between manufacturers and purchasers.

NOTE 12 This document does not specify emission requirements, these are specified in IEC 62052-11:2020, 9.3.14.

PDF Catalog

PDF Pages PDF Title
2 undefined
7 Blank Page
8 Annex ZZ (informative)Relationship between this European standard and the essential requirements of Directive 2014/30/EU [2014 OJ L96] aimed to be covered
9 English
CONTENTS
10 FOREWORD
12 INTRODUCTION
14 1 Scope
15 2 Normative references
3 Terms and definitions
16 4 Standard electrical values
4.1 Voltages
4.2 Currents
4.2.1 General
4.2.2 Starting current (see Table 1)
4.2.3 Minimum current (see Table 2)
4.2.4 Maximum current
4.3 Frequencies
4.4 Power consumption
Table 1 – Starting current
Table 2 – Minimum current
17 5 Construction requirements
6 Meter marking and documentation
7 Accuracy requirements
7.1 General test conditions
7.2 Methods of accuracy verification
7.3 Measurement uncertainty
7.4 Meter constant
7.5 Initial start-up of the meter
7.6 Test of no-load condition
7.7 Starting current test
7.8 Repeatability test
7.9 Limits of error due to variation of the current
18 7.10 Limits of error due to influence quantities
Table 3 – Acceptable percentage error limits (single-phase meters and poly-phase meters with balanced loads or single-phase loads)
19 Table 4 – Acceptable limits of variation in percentage error due to influence quantities
20 7.11 Time-keeping accuracy
8 Climatic requirements
21 9 The effects of external influences
10 Type test
22 Annex A (informative) Geometric representation of active and reactive power
Figure A.1 – Recommended geometric representation
23 Figure A.2 – Alternative geometric representation
24 Annex B (informative) Summary of changes
BS EN IEC 62053-23:2021+A11:2021
$142.49