Shopping Cart

No products in the cart.

BS EN IEC 62522:2024

$167.15

Calibration of tuneable laser sources

Published By Publication Date Number of Pages
BSI 2024 44
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 62522:2024 is available as IEC 62522:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62552:2024 provides a stable and reproducible procedure to calibrate the wavelength and power output of a tuneable laser against reference instrumentation such as optical power meters and optical wavelength meters (including optical frequency meters) that have been previously traceably calibrated.

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
6 English
CONTENTS
8 FOREWORD
10 INTRODUCTION
11 1 Scope
2 Normative references
3 Terms, definitions, and abbreviated terms
3.1 Terms and definitions
14 3.2 Abbreviated terms
4 Preparation for calibration
4.1 Organization
4.2 Traceability
4.3 Preparation
15 4.4 Reference calibration conditions
5 Wavelength calibration
5.1 Overview
Tables
Table 1 – Source of uncertainty for wavelength calibration
16 5.2 Wavelength calibration at reference conditions
5.2.1 Set-up
5.2.2 Calibration equipment
5.2.3 Procedure for wavelength calibration
Figures
Figure 1 – Measurement set-up for wavelength calibration
17 5.2.4 Dependence on conditions
Figure 2 – Measurement set-up for temperature dependence
18 Figure 3 – Measurement set-up for wavelength stability
19 5.2.5 Uncertainty at reference conditions
20 5.3 Wavelength calibration at operating conditions
5.3.1 General
5.3.2 Optical power dependence
Figure 4 – Measurement set-up for optical power dependence
21 5.3.3 Uncertainty at operating conditions
22 6 Optical power calibration
6.1 Overview
6.2 Optical power calibration at reference conditions
6.2.1 Set-up
Figure 5 – Measurement set-up for intrinsic optical power calibration
Table 2 – Source of uncertainty for optical power calibration
23 6.2.2 Calibration equipment
6.2.3 Procedure for power calibration at reference conditions
24 6.2.4 Dependence on conditions
Figure 6 – Measurement set-up for temperature dependence
25 Figure 7 – Measurement set-up for optical power stability
26 Figure 8 – Measurement set-up for connection repeatability/reproducibility
27 6.2.5 Uncertainty at reference conditions
6.3 Optical power calibration at operating conditions
6.3.1 General
28 6.3.2 Wavelength dependence
Figure 9 – Measurement set-up for wavelength dependence
29 6.3.3 Uncertainty at operating conditions
7 Documentation
7.1 Calibration data and uncertainty
30 7.2 Calibration conditions
31 Annex A (normative) Mathematical basis for measurement uncertainty calculations
A.1 General
A.2 Type A evaluation of uncertainty
32 A.3 Type B evaluation of uncertainty
33 A.4 Determining the combined standard uncertainty
A.5 Reporting
34 Annex B (informative) Other testing
B.1 General
B.2 Wavelength tuning resolution
B.2.1 Set-up
B.2.2 Testing equipment
B.2.3 Testing procedure for determining wavelength resolution
Figure B.1 – Measurement set-up for wavelength resolution
35 B.3 Optical power tuning resolution
B.3.1 Set-up
B.3.2 Testing equipment
B.3.3 Testing procedure for optical power resolution
Figure B.2 – Measurement set-up for optical power resolution setting test
36 B.4 Signal-to-source spontaneous emission ratio
B.4.1 General
B.4.2 Set-up
B.4.3 Testing equipment
B.4.4 Testing procedure for determining signal-to-source spontaneous emission ratio
Figure B.3 – Measurement set-up for signal to total source spontaneous emission ratio
37 B.5 Side-mode suppression ratio
B.5.1 General
B.5.2 Set-up
Figure B.4 – Measurement of the signal to spontaneous emission ratio
Figure B.5 – Measurement set-up for the side-mode suppression ratio test
38 B.5.3 Testing equipment
B.5.4 Testing procedure for determining the side-mode suppression ratio
39 Figure B.6 – Optical spectrum of tuneable laser source
Figure B.7 – Measurement set-up for SMSR
41 Annex C (informative) Linear to dB scale conversion of uncertainties
C.1 Definition of decibel
C.2 Conversion of relative uncertainties
43 Bibliography
BS EN IEC 62522:2024
$167.15