BS EN IEC 62828-2:2018:2020 Edition
$142.49
Reference conditions and procedures for testing industrial and process measurement transmitters – Specific procedures for pressure transmitters
Published By | Publication Date | Number of Pages |
BSI | 2020 | 30 |
This part of IEC 62828 establishes specific procedures for testing pressure process measurement transmitters (PMT) used in measuring and control systems for industrial processes and for machinery control systems.
A pressure PMT can feature a remote seal to bring the process variable to the sensing element in the PMT. When the remote seal cannot be separated from the PMT, the complete device is tested.
For general test procedures, reference is made to IEC 62828-1, which is applicable to all types of process measurement transmitters.
NOTE In industrial and process applications, to indicate the process measurement transmitters, it is common also to use the terms “industrial transmitters”, or “process transmitters”.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | English CONTENTS |
9 | FOREWORD |
11 | INTRODUCTION |
12 | 1 Scope 2 Normative references 3 Terms and definitions 3.1 General |
13 | Figures Figure 1 ā Measuring range and associated properties of a pressure PMT |
14 | 3.2 Terms related the process conditions 4 General description of the device and overview 5 Reference test conditions |
15 | 6 Test procedures 6.1 General 6.2 Tests at standard and operating reference test conditions 6.2.1 General 6.2.2 Accuracy test suitable for routine and acceptance tests Figure 2 ā Schematic example of a test set-up for pressure PMT |
16 | 6.2.3 Overpressure Figure 3 ā Example of measured error plot Tables Table 1 ā Example of measured errors |
17 | Figure 4 ā Procedure for the determination of the unilateral overpressure error |
18 | 6.2.4 Influence of static pressure Figure 5 ā Schematic example of test set-up for determinethe effect of the static pressure |
19 | Figure 6 ā Procedure for the determination of the zero point error with static pressure |
20 | 6.2.5 Long-term drift Figure 7 ā Procedure for the determination of the span error for static pressure |
21 | 6.2.6 Leakage test 6.2.7 Additional tests for diaphragm/remote seals ā Influence of process temperature (long term) 7 Test report and technical documentation 7.1 General |
22 | 7.2 Total probable error |
23 | Annex A (informative)Relationship between the SI unit and other pressure related units Table A.1 ā Relationship between the SI unit and other pressure related units |
24 | Annex B (informative)Pressure process measurement transmitter (PMT) B.1 General description of a pressure PMT B.2 Typical PMTs |
25 | Figure B.1 ā Schematic example of intelligent PMT model |
26 | Annex C (informative)Example of signal current range for a 4 to 20 mA PMT C.1 Signal current range of a 4 mA to 20 mA transmitter (before adjustment) C.2 Proportional range C.3 Normal range C.4 Underrange Figure C.1 ā Signal current range of a 4 mA ā 20 mA transmitter (before adjustment) |
27 | C.5 Overrange C.6 Low alarm C.7 High alarm |
28 | Bibliography |