BS EN IEC 62877-1:2023 – TC
$134.27
Tracked Changes. Electrolyte and water for vented lead acid accumulators – Requirements for electrolyte
Published By | Publication Date | Number of Pages |
BSI | 2023 | 38 |
IEC 62877-1:2023 is available as IEC 62877-1:2023 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 62877-1:2023 applies to electrolytes and their components used for filling vented lead acid batteries with dry-charged cells and for electrolyte replenishment, replacement or electrolyte density adjustment of batteries in operation. This document defines the composition, purity and properties of electrolyte, for application where specific instructions from the battery manufacturer are not available. This second edition cancels and replaces the first edition published in 2016. This edition includes the following significant technical changes with respect to the previous edition: – Addition of the concentration values of halogens in Table 4.
PDF Catalog
PDF Pages | PDF Title |
---|---|
21 | undefined |
24 | Annex ZA (normative)Normative references to international publicationswith their corresponding European publications |
25 | English CONTENTS |
26 | FOREWORD |
28 | 1 Scope 2 Normative references 3 Terms and definitions |
30 | 4 Preparation of electrolyte for lead acid batteries |
31 | 5 Physical properties of diluted sulphuric acid as electrolyte 5.1 Dependence of sulphuric acid electrolyte density on temperature 5.2 Relationship of acid electrolyte density at 25 °C with the content of sulphuric acid Table 1 – Correction factor to convert the acid electrolyte density found at the measuring temperature to that at the specified reference temperature |
32 | 5.3 Electrolyte density in relation to the state of discharge Table 2 – Acid electrolyte density at 25 °C versus percentage of sulphuric acid |
33 | 6 Requirements for sulphuric acid used as electrolyte 6.1 Impurities of sulphuric acid at high concentration 6.2 Impurities limits of sulphuric acid electrolyte for first filling Table 3 – Maximum allowed impurities in diluted sulphuric acid in the density range dn ≤ 1,30 kg/l when used as filling electrolyte for lead acid batteries |
34 | 6.3 Impurities limits for sulphuric acid electrolyte in operation 7 Storage of electrolyte Table 4 – Maximum allowed impurities in diluted sulphuric acid in the density range dn ≤ 1,30 kg/l when this acid is acting as the operating electrolyte in lead acid batteries |
35 | 8 Remedy in the event of damage due to the electrolyte |
36 | Bibliography |