BS EN IEC 62985:2019

$142.49

Corrigendum 1. Methods for calculating size specific dose estimates (SSDE) for computed tomography

Published By Publication Date Number of Pages
BSI 2019 28
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 undefined
5 Annex ZA(normative)Normative references to international publicationswith their corresponding European publications
7 CONTENTS
9 FOREWORD
11 INTRODUCTION
12 1 Scope
2 Normative references
3 Terms and definitions
14 4 Verification of method used to calculate DW(z)
4.1 General
4.2 Characteristics of the water phantoms
15 4.3 Characteristics of the anthropomorphic phantom
4.4 Generation of DW,REF(z) for the water phantoms
4.5 Verification of DW,REF for the water phantoms
4.6 Generation of DW,IMP for the water phantoms
16 4.7 Verification of DW,IMP(z) against DW,REF(z) for the water phantoms
4.8 Generation of DW,REF(z) for the anthropomorphic phantom
Table 1 – Anthropomorphic phantom regions to be scanned
17 4.9 Generation of DW,IMP(z) for the anthropomorphic phantom
4.10 Verification of DW,IMP(z) against DW,REF(z) for the anthropomorphic phantom
5 Requirements and limitations
5.1 Calculation of SSDE and DW for ct scanners and RDIMS
5.2 Pre-scan display of SSDE for ct scanners
5.3 Post-scan updating of SSDE and DW for ct scanners
18 5.4 Pre and post-scan display of SSDE and DW for ct scanners
5.5 Post-scan recording of SSDE and DW for ct scanners
5.6 Limitations of calculation and display of SSDE and DW
5.7 Requirements for identification of limitations in the accompanying documents
19 5.8 Updating SSDE conversion factors, ƒ
20 Annex A (normative)Ssde conversion factors
A.1 Clarification regarding the use of effective diameter versus DW
A.2 Equation for determination of SSDE conversion factor
Table A.1 – Ssde Conversion factor as a function of DW
21 Figure A.1 – Visualization of ƒ(Dw) versus DW for the bodyand head parameters provided in Table A.1
22 Annex B (normative)Language regarding the general limitations of the ssde methodologyfor use in the accompanying documents
23 Annex C (informative)Estimates of the magnitude of uncertaintiesfrom special clinical scenarios
C.1 General
C.2 Neck included in scanned anatomy
C.3 Range of scan projection radiograph exceeded
C.4 Single or bilateral extremities scanned
24 C.5 Patient not positioned at the centre of rotation along the source/detector direction
C.6 Patient anatomy outside the scan field of view
C.7 Foreign objects within the scanned projection radiograph or scan volume
25 Bibliography
26 Index of defined terms used in this document
BS EN IEC 62985:2019
$142.49