Shopping Cart

No products in the cart.

BS EN IEC 63203-402-1:2022:2023 Edition

$142.49

Wearable electronic devices and technologies – Performance measurement of fitness wearables. Test methods of glove-type motion sensors for measuring finger movements

Published By Publication Date Number of Pages
BSI 2023 24
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

IEC 63203-402-1:2022 specifies test methods for wearable glove-type motion sensors to measure finger movements. The measurement methods include goniometric parameters related to the finger postures and flexion dynamics. Glove-type motion sensors are the type of gloves considered within the scope of this document for testing and measurement. This document describes direct and indirect measurement methods. In the direct measurement method, the angles of the joints of each finger are directly measured by a goniometer. The indirect method uses a measurement device such as a servomotor-based angle-measuring device. This document is applicable to angle measurement of all gloves with glove-type motion sensors without limitation of the device technology or size.

PDF Catalog

PDF Pages PDF Title
2 undefined
7 Annex ZA (normative)Normative references to international publicationswith their corresponding European publications
9 English
CONTENTS
10 FOREWORD
12 1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms
13 3.2 Angle between finger joints
14 4 Test conditions and method
4.1 Test conditions
4.2 Preparation of gloves under test
4.3 Test methods
4.3.1 Direct measurement test procedure: angle between finger joints
Figures
Figure 1 – Position of DIP, PIP, IP and MCP
15 Figure 2 – Direct measurement method using a manual goniometer
16 4.3.2 Indirect measurement test procedure: angle between finger joints with sensors
Table 1 – Comparison of angle data measured with a glove sensor and goniometer
17 Figure 3 – Test setup based on the servomotor for sensor angle measurement
Figure 4 – Test procedure of angle measurement inthe wearable glove based on the servomotor
18 5 Test report
Table 2 – Comparison of angle data measured with a glove sensor and servomotor
20 Annex A (informative)Glove-type motion sensors
A.1 Glove-type motion sensors
A.2 Examples by sensing type
A.2.1 Schematic of a resistive-type glove sensor
Figure A.1 – Examples of glove-type motion sensors
Figure A.2 – Schematic of a resistive-type glove sensor
21 A.2.2 Schematic of a capacitive-type glove sensor
A.2.3 Schematic of a piezoelectric-type glove sensor
Figure A.3 – Schematic of a capacitive-type glove sensor
Figure A.4 – Structure of a piezoelectric-type glove sensor
22 Bibliography
BS EN IEC 63203-402-1:2022
$142.49