BS EN IEC/IEEE 65700:2018

$198.66

Bushings for DC application

Published By Publication Date Number of Pages
BSI 2018 58
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 CONTENTS
11 FOREWORD
13 INTRODUCTION
14 1 Scope
2 Normative references
15 3 Terms, definitions and symbols
3.1 Terms and definitions
17 3.2 List of variables
18 4 Ratings
4.1 Rated voltages
4.1.1 Rated continuous DC voltage
4.1.2 Rated peak voltage
4.2 Insulation levels
4.3 Rated currents
4.3.1 Pure DC applications
19 4.3.2 Combined voltage applications
4.4 Rated frequency
4.5 Pollution parameters
20 5 Operating conditions
5.1 General
Tables
Table 1 – Temperature of ambient air and immersion media (see 5.1)
21 5.2 Factors affecting the design, testing and application
5.3 Altitude correction
22 Figures
Figure 1 – Altitude correction factor
23 5.4 Interchangeability
6 General requirements
6.1 Electrical requirements
6.2 Mechanical requirements
6.3 Nameplate markings
24 7 Test requirements
7.1 General requirements
7.2 Test Conditions
7.2.1 Air temperature
7.2.2 Humidity
7.2.3 Correction factors
25 7.3 Test classification
7.3.1 Type (or design) tests
26 7.3.2 Routine tests
7.3.3 Special tests
8 Type tests
8.1 Dry power-frequency voltage withstand test with partial discharge measurement
8.1.1 Applicability
Table 2 – Type, routine and special tests
27 8.1.2 Test method and requirements
8.1.3 Acceptance
8.2 Dry lightning impulse voltage withstand test (BIL)
8.2.1 Applicability
8.2.2 Test method and requirements
8.2.3 Acceptance
8.3 Dry or wet switching impulse voltage withstand test (SIL)
8.3.1 Applicability
28 8.3.2 Test method and requirements
8.3.3 Acceptance
8.4 Electromagnetic compatibility tests (EMC)
8.4.1 Emission test
8.4.2 Immunity test
8.5 Temperature rise test
8.5.1 Applicability
29 8.5.2 Test method and requirements
8.5.3 Acceptance
30 8.6 Cantilever load withstand test
8.6.1 Applicability
8.6.2 Test method and requirements
Table 3 – Minimum values of cantilever withstand load
31 8.6.3 Acceptance
8.7 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
8.8 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
8.9 Verification of dimensions
8.10 Draw-lead bushing cap pressure test
8.10.1 Applicability
8.10.2 Test method and requirements
8.10.3 Acceptance
9 Routine tests
9.1 Measurement of dielectric dissipation factor (tan δ) and capacitances
9.1.1 Applicability
9.1.2 Test method and requirements
9.1.3 Acceptance
32 9.2 Dry lightning impulse voltage withstand test (BIL)
9.2.1 Applicability
9.2.2 Test method and requirements
9.2.3 Acceptance
9.3 Dry power-frequency voltage withstand test with partial discharge measurement
9.3.1 Applicability
9.3.2 Test method and requirements
Table 4 – Maximum values of tan δ and tan δ increase
33 9.3.3 Acceptance
9.4 DC applied voltage withstand test with partial discharge measurement
9.4.1 Applicability
Table 5 – Maximum values of partial discharge quantity
34 9.4.2 Test method and requirements
9.4.3 Acceptance
35 9.5 Polarity reversal test with partial discharge measurement
9.5.1 Applicability
9.5.2 Test method and requirements
Figure 2 – Polarity reversal test profile
36 9.5.3 Acceptance
9.6 Dry Switching impulse withstand test
9.6.1 Applicability
37 9.6.2 Test method and requirements
9.6.3 Acceptance
9.7 Test of tap insulation
9.8 Internal pressure test on gas-filled, gas-insulated and gas-impregnated bushings
9.9 Tightness test on liquid-filled, compound-filled and liquid-insulated bushings
9.10 Tightness test on gas-filled, gas-insulated and gas-impregnated bushings
9.11 Tightness test at the flange or other fixing device
9.12 Visual inspection and dimensional check
10 Special tests
38 10.1 Artificial pollution test
10.1.1 Applicability
10.1.2 Test method and requirements
10.1.3 Acceptance
10.2 Even wetting DC voltage test
10.2.1 Applicability
10.2.2 Test method and requirements
39 10.2.3 Acceptance
10.3 Uneven wetting DC voltage test
10.3.1 Applicability
10.3.2 Test method and requirements
10.3.3 Acceptance
40 11 Recommendations for transport, storage, erection, operation and maintenance
11.1 Conditions during transport, storage and installation
11.2 Installation
11.3 Unpacking and lifting
11.4 Assembly
11.4.1 Mounting
41 11.4.2 Connections
11.4.3 Final installation inspection
11.5 Operation
42 11.6 Maintenance
11.6.1 General
11.6.2 Recommendation for the manufacturer
11.6.3 Recommendations for the user
43 11.6.4 Failure report
44 12 Safety
12.1 Electrical aspects
12.2 Mechanical aspects
12.3 Thermal aspects
13 Environmental aspects
45 Annex A (informative)
A.1 Bushings used in voltage source converters (VSC) HVDC schemes
A.1.1 Introduction
46 Figure A.1 – Two-level VSC HVDC converter station applied in a bipolar scheme with DC cable transmission
47 A.1.2 Design
Figure A.2 – Multi-level VSC HVDC converter station applied in a monopolar scheme with DC overhead line transmission
48 A.1.3 Tests
A.1.4 Supporting Published Material
49 Annex B (informative)
B.1 Temperature rise test methods for the determination of the equivalent test current
B.1.1 Introduction
B.2 Basics concerning the losses in distorted operation
50 B.3 Analytical calculation
B.4 Finite element method calculation
51 B.5 Calculation by enhancement factors as described in IEC 61378–1
52 B.6 Examples of calculation
Table B.1 – Valve side connected bushing current harmonic spectrum
53 B.6.1 Calculation based on the analytical method
Table B.2 – Calculation based on the analytical method
54 B.6.2 Calculation based on Finite Element Method
Table B.3 – Calculation based on Finite Element Method
55 B.6.3 Calculation based on the enhancement factor according IEC 61378–1
Table B.4 – Calculation based IEC 61378-1 enhancement factor FCE
56 B.7 References
57 Bibliography
BS EN IEC/IEEE 65700:2018
$198.66