Agricultural and forestry machines. Inspection of sprayers in use – Aerial spray systems
Published By | Publication Date | Number of Pages |
BSI | 2021 | 22 |
This document specifies the requirements, test methods and verification of the inspection of aerial fixed wing and rotary aircraft spray systems for agriculture, forestry, turf, and vegetation control in transport access ways (such as gas and electric lines), with regard to minimizing the potential risk of environmental contamination during use.
This document applies only to manned aerial aircraft. It does not cover aircraft safety and design criteria for air worthiness, aircraft registration, pilot or operator requirements, all of which are specified separately by countries or regions.
This document relates mainly to the condition of the equipment with respect to its potential risk for the environment and its performance to achieve good applications.
The general requirements of ISO 16122-1 apply where appropriate, including for the protection of inspectors during an inspection.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | European foreword |
5 | Annex ZA (informative) Relationship between this European Standard and the essential requirements of Directive 2009/128/EC aimed to be covered |
8 | Foreword |
9 | Introduction |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Requirements 4.1 General requirements 4.1.1 Static leak test 4.1.2 Dynamic leak test 4.2 Sprayer tanks 4.2.1 General 4.2.2 Tank opening(s) |
13 | 4.2.3 Strainers 4.2.4 Emptying 4.2.5 Tank emptying device 4.2.6 Tank contents indicator(s) 4.2.7 Tank agitation 4.3 Hoses and lines 4.3.1 General 4.3.2 Bending/abrasion |
14 | 4.4 Spray boom 4.4.1 Spraying section 4.4.2 Nozzle orientation 4.5 Pressure drop 4.6 Filters |
15 | 4.7 Nozzles 4.7.1 Mounting 4.7.2 Flow rate and spray quality 4.8 Measuring systems 4.8.1 General |
16 | 4.8.2 Control 4.8.3 Pressure indicator (s) 4.8.4 Flow rate and other instruments |
17 | 4.8.5 Pressure adjusting devices 4.9 Volume rate per area 4.10 Safety/Exposure 4.10.1 General 4.10.2 Inspector safety 4.11 Flow control |
18 | 5 Test facility and methods 5.1 General 5.2 Validation pressure indicator(s) 5.3 Verification method of the sprayer pressure indicator 6 Inspection report |
20 | Annex A (informative) Nozzle drop size category websites and aerial deposition models |