BS EN ISO 22476-4:2021
$215.11
Geotechnical investigation and testing. Field testing – Prebored pressuremeter test by Ménard procedure
Published By | Publication Date | Number of Pages |
BSI | 2021 | 72 |
This document specifies equipment requirements, the execution of and reporting on the Ménard pressuremeter test.
This document describes the procedure for conducting a Ménard pressuremeter test in natural grounds, treated or untreated fills, either on land or off-shore.
The pressuremeter tests results of this document are suited to a quantitative determination of ground strength and deformation parameters. They can yield lithological information in conjunction with measuring while drilling performed when creating the borehole (according to ISO 22476-15 ). They can also be combined with direct investigation (e.g. sampling according to ISO 22475-1 ) or compared with other in situ tests (see EN 1997-2 ).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | Foreword |
8 | Introduction |
11 | 1 Scope 2 Normative references 3 Terms, definitions and symbols 3.1 Terms and definitions |
13 | 3.2 Symbols |
16 | 4 Equipment 4.1 General description 4.2 Pressuremeter probe 4.2.1 General |
18 | 4.2.2 Probe with flexible cover 4.2.3 Probe with flexible cover and an additional more rigid protection |
19 | 4.2.4 Probe with flexible cover and slotted tube |
20 | 4.3 Connecting lines and injected fluid |
21 | 4.4 Pressure and volume control unit 4.4.1 General 4.4.2 Measurement and control |
22 | 4.4.3 Data logger 5 Test procedure 5.1 Assembling the parts |
23 | 5.2 Calibration and corrections 5.3 Pressuremeter test pocket and probe placing 5.4 Preparation for testing |
24 | 5.5 Establishing the loading programme |
25 | 5.6 Establishing the pressure of the guard cells for tri-cell probes 5.7 Expansion 5.7.1 General 5.7.2 Readings and recordings |
26 | 5.7.3 End of test 5.8 Back-filling of the pockets 5.9 Safety requirements 6 Test results 6.1 Data sheet and field print-out or display 6.1.1 Data sheet for type A control unit |
27 | 6.1.2 Site print-out for type B and C control units 6.1.3 Raw pressuremeter curve 6.2 Corrected pressuremeter curve |
28 | 6.3 Calculated results |
29 | 7 Reporting 7.1 General 7.2 Field report 7.3 Test report 7.3.1 General 7.3.2 Ménard pressuremeter test report |
30 | 7.3.3 Pressuremeter tests log |
32 | Annex A (normative) Geometrical features of pressuremeter probes |
34 | Annex B (normative) Calibration and corrections |
43 | Annex C (normative) Placing the pressuremeter probe in the ground |
51 | Annex D (normative) Obtaining pressuremeter parameters |
61 | Annex E (normative) Uncertainties |
63 | Annex F (informative) Pressuremeter test records |
70 | Bibliography |