Shopping Cart

No products in the cart.

BS EN ISO 4892-2:2000 2006

$102.76

Plastics. Methods of exposure to laboratory light sources – Xenon-arc sources

Published By Publication Date Number of Pages
BSI 2006 14
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 BRITISH STANDARD
2 Committees responsible for this British Standard
3 Contents
5 EUROPEAN STANDARD
NORME EUROPÉENNE
EUROPÄISCHE NORM
EN ISO 4892-2
ICS 83.080.00
Incorporating Corrigendum November 2005
English version
Plastics – Methods of exposure to laboratory light sources – Part 2: Xenon-arc sources
(ISO 4892-2:1994)
CEN
European Committee for Standardization
Comité Européen de Normalisation
Europäisches Komitee für Normung
Central Secretariat: rue de Stassart 36, B-1050 Brussels
© 1999 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members
Ref. No. EN ISO 4892-2:1999 E
7 1 Scope
2 Normative references
3 Principle
3.1 A xenon arc, when fitted with suitable filters and properly maintained, produces radiation with a spectral energy distribution similar to that of terrestrial sunlight in the ultraviolet and visible regions of the spectrum.
3.2 Specimens of the samples to be tested are exposed to the light source under controlled environmental conditions.
3.3 The procedure may include measurement of the irradiance and radiant exposure at the surface of the specimen.
3.4 It is recommended that a similar material of known behaviour be exposed simultaneously with the experimental material as a reference.
3.5 Intercomparison of results obtained from specimens exposed in different apparatus should not be made unless reproducibility has been established among devices for the material to be tested.
4 Apparatus
4.1 Laboratory light source
8 Relative spectral irradiance for artificial weathering (method A)
Relative spectral irradiance for daylight behind window glass (method B)
4.2 Test chamber
9 4.3 Radiometer
4.4 Black-standard/black-panel thermometer
4.5 Relative-humidity control equipment
4.6 Spray system
4.7 Specimen holders
4.8 Apparatus to assess changes in properties
5 Test specimens
6 Test conditions
6.1 Black-standard/black-panel temperature
10 6.2 Relative humidity
6.3 Spray cycle
6.4 Cycles with dark periods
7 Procedure
7.1 Mounting the test specimens
7.2 Exposure
7.3 Measurement of radiant exposure
7.4 Determination of changes in properties after exposure
8 Exposure report
11 (informative) Xenon-arc lamp apparatus
(informative) Xenon-arc lamp apparatus
Apparatus with air-cooled xenon-arc lamps
Description and conditions of use
12 Temperature and humidity control
Apparatus with water-cooled xenon-arc lamps
Description and conditions of use
13 Temperature and humidity control
BS EN ISO 4892-2:2000 2006
$102.76