BS EN ISO 9917-2:2017
$142.49
Dentistry. Water-based cements – Resin-modified cements
Published By | Publication Date | Number of Pages |
BSI | 2017 | 30 |
This document specifies requirements and test methods for water-based dental cements in which setting is achieved by a combination of an acid-base reaction and polymerization. The materials are intended for luting, base or lining, restoration and tooth core build up purposes.
EXAMPLE Conventional glass polyalkenoate cements are normally formed by reacting an ion-leachable aluminosilicate glass with a polyalkenoic acid in an aqueous environment. Materials that fall within the scope of this document will normally be able to effect setting by such an aqueous acid-base type reaction but in addition will be able to undergo setting by polymerization.
NOTE The attention of manufacturers and test laboratories is drawn to the closely-related International Standards ISO 4049 and ISO 9917‑1 so that they can consider which is the most appropriate for evaluating any individual product.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
4 | European foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Classification and applications 4.1 Classification 4.2 Applications |
11 | 5 Requirements 5.1 Materials 5.2 Working time 5.3 Setting time — Class 1 and Class 3 materials only 5.4 Film thickness — Luting materials only (see 4.2 ) 5.5 Flexural strength 5.6 Radio-opacity 5.7 Shade and colour stability — Restorative materials only 6 Sampling |
12 | 7 Test conditions and preparation of test specimens 7.1 Test conditions 7.2 Method of mixing 7.3 Inspection 8 Packaging, marking and information to be supplied by the manufacturer 8.1 Packaging |
13 | 8.2 Marking and instructions for use |
16 | Annex A (normative) Determination of working time and setting time |
18 | Annex B (normative) Determination of film thickness — Luting materials only |
20 | Annex C (normative) Determination of flexural strength |
25 | Annex D (normative) Determination of radio-opacity |
27 | Annex E (normative) Determination of shade and colour stability — Restorative (except for tooth core build-up) and luting materials only |
29 | Bibliography |