BS ISO 13142:2021
$142.49
Optics and photonics. Lasers and laser-related equipment. Cavity ring-down method for high-reflectance and high-transmittance measurements
Published By | Publication Date | Number of Pages |
BSI | 2021 | 26 |
This document specifies measurement procedures for the precise determination of the high reflectance or high transmittance (>99 %) of optical laser components.
The methods given in this document are intended to be used for the testing and characterization of high reflectance of both concave and plane mirrors or high transmittance of plane windows used in laser systems and laser-based instruments. The reflectance of convex mirrors or transmittance of positive or negative lenses can also be tested by taking into consideration the radius of curvature of the mirror surface or the focal length of the lens. This document is complementary to ISO 15368 which specifies the measurement procedures for the determination of reflectance and transmittance of optical components with spectrophotometry. ISO 15368 is applicable to the measurements of reflectance and transmittance in the range from 0 % to 100 % with a typical accuracy of ±0,3 %, and is therefore not applicable to the precise measurements of reflectance and transmittance higher than 99,9 %.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols used and units of measure 5 Test principles 5.1 General 5.2 Decay time of initial cavity and reflectance of cavity mirrors |
12 | 5.3 Decay time of test cavity and reflectance/transmittance of test sample |
13 | 5.4 High reflectance/transmittance measurement with an optical feedback CRD technique |
14 | 6 Preparation of test sample and measurement arrangement 6.1 Test sample 6.2 Laser source |
15 | 6.3 Ring-down cavity 6.4 Detection unit 6.5 Data acquisition and processing |
16 | 6.6 Environment 7 Test procedure 7.1 General 7.2 Measurement of decay time of initial cavity |
17 | 7.3 Calculation of reflectance of cavity mirrors 7.4 Measurement of decay time of test cavity 7.5 Calculation of reflectance/transmittance of test sample 7.6 Assessments of the measurement |
18 | 8 Main error factors 8.1 Influence of the instrumental response time on reflectance/transmittance measurement 8.1.1 General 8.1.2 Multi-parameter fitting method |
19 | 8.1.3 Data truncation method 8.2 Measurement error of the reflectance of cavity mirrors |
20 | 8.3 Measurement error of the reflectance/transmittance of test sample 9 Test report |
22 | Annex A (informative) Reflectance/transmittance reliability check experiment |
23 | Annex B (informative) Test report |
25 | Bibliography |