BS ISO 15864:2021 – TC
$246.62
Tracked Changes. Space systems. General test methods for spacecraft, subsystems and units
Published By | Publication Date | Number of Pages |
BSI | 2021 | 94 |
This document provides the baseline standard on the subject of testing at the system, subsystem and unit levels for applicable unmanned spacecraft programmes. It also provides the requirements for documentation associated with testing activities.
This document contains provisions for qualification and acceptance testing, or proto-flight testing (PFT). It assumes that hardware development is complete.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 30441217 |
49 | A-30400009 |
50 | undefined |
57 | Foreword |
58 | Introduction |
59 | 1 Scope 2 Normative references 3 Terms, definitions and abbreviated terms 3.1 Terms and definitions |
61 | 3.2 Abbreviated terms 4 General requirements 4.1 Testing philosophy 4.2 Tailoring of requirements |
62 | 4.3 Development tests 4.4 Qualification tests 4.5 Acceptance tests 4.6 Proto-flight tests 4.7 Prelaunch validation tests |
63 | 4.8 Retest 4.8.1 General 4.8.2 Retest due to design modification after completion of qualification 4.8.3 Retest due to non-conformance 4.8.4 Retest after refurbishment 4.8.5 Retest during and after long-term storage 4.9 Test documentation 4.9.1 General 4.9.2 Test plans |
64 | 4.9.3 Test specifications 4.9.4 Test procedures 4.9.5 Test data |
65 | 4.9.6 Test reports 4.9.7 Test log 4.10 Tests facilities and other requirements 4.10.1 General 4.10.2 Test condition tolerances 4.10.3 Instrumentation 5 Spacecraft system tests 5.1 Test items and sequence |
66 | 5.2 Test levels and duration 6 Subsystem/unit tests 6.1 Test items and sequence 6.2 Test levels and duration |
74 | 7 Test requirements 7.1 General 7.2 Functional test 7.2.1 Purpose of test 7.2.2 Test facilities and set-up as basic requirements 7.2.3 Test article configuration 7.2.4 Monitoring during test 7.2.5 Test levels and duration 7.2.6 Test condition and guidelines |
75 | 7.2.7 Tailoring guide 7.3 Electromagnetic compatibility (EMC) test 7.3.1 Purpose of test 7.3.2 Test facilities and set-up as basic requirements 7.3.3 Test article configuration 7.3.4 Monitoring during test 7.3.5 Test levels and duration 7.3.6 Test condition and guidelines 7.3.7 Tailoring guide |
76 | 7.4 Magnetic test 7.4.1 Purpose of test 7.4.2 Test facilities and set-up as basic requirements 7.4.3 Test article configuration 7.4.4 Monitoring during test 7.4.5 Test levels and duration 7.4.6 Test condition and guidelines 7.4.7 Tailoring guide 7.5 Antenna pattern test 7.5.1 Purpose of test 7.5.2 Test facilities and set-up as basic requirements 7.5.3 Test article configuration |
77 | 7.5.4 Monitoring during test 7.5.5 Test levels and duration 7.5.6 Test condition and guidelines 7.5.7 Tailoring guide 7.6 Optical alignment measurement 7.6.1 Purpose of test 7.6.2 Test facilities and set-up as basic requirements 7.6.3 Test article configuration 7.6.4 Monitoring during test 7.6.5 Test levels and duration 7.6.6 Test condition and guidelines 7.6.7 Tailoring guide |
78 | 7.7 Physical property measurement 7.7.1 Purpose of test 7.7.2 Test facilities and set-up as basic requirements 7.7.3 Test article configuration 7.7.4 Monitoring during test 7.7.5 Test levels and duration 7.7.6 Test condition and guidelines 7.7.7 Tailoring guide 7.8 Dynamic balance 7.8.1 Purpose of test 7.8.2 Test facilities and set-up as basic requirements 7.8.3 Test article configuration |
79 | 7.8.4 Monitoring during test 7.8.5 Test levels and duration 7.8.6 Test condition and guidelines 7.8.7 Tailoring guide 7.9 Launcher/spacecraft interface test 7.9.1 Purpose of test 7.9.2 Test facilities and set-up as basic requirements 7.9.3 Test article configuration 7.9.4 Monitoring during test 7.9.5 Test levels and duration 7.9.6 Test condition and guidelines |
80 | 7.9.7 Tailoring guide 7.10 Static load test 7.10.1 Purpose of test 7.10.2 Test facilities and set-up as basic requirements 7.10.3 Test article configuration 7.10.4 Monitoring during test 7.10.5 Test levels and duration 7.10.6 Test condition and guidelines 7.10.7 Tailoring guide 7.11 Acceleration test 7.11.1 Purpose of test |
81 | 7.11.2 Test facilities and set-up as basic requirements 7.11.3 Test article configuration 7.11.4 Monitoring during test 7.11.5 Test levels and duration 7.11.6 Test condition and guidelines 7.11.7 Tailoring guide 7.12 Modal survey 7.12.1 Purpose of test 7.12.2 Test facilities and set-up as basic requirements 7.12.3 Test article configuration |
82 | 7.12.4 Monitoring during test 7.12.5 Test levels and duration 7.12.6 Test condition and guidelines 7.12.7 Tailoring guide 7.13 Sinusoidal vibration test 7.13.1 Purpose of test 7.13.2 Test facilities and set-up as basic requirements 7.13.3 Test article configuration 7.13.4 Monitoring during test |
83 | 7.13.5 Test levels and duration 7.13.6 Test condition and guidelines 7.13.7 Tailoring guide 7.14 Random vibration test 7.14.1 Purpose of test 7.14.2 Test facilities and set-up as basic requirements 7.14.3 Test article configuration 7.14.4 Monitoring during test |
84 | 7.14.5 Test levels and duration 7.14.6 Test condition and guidelines 7.14.7 Tailoring guide 7.15 Acoustic test 7.15.1 Purpose of test 7.15.2 Test facilities and set-up as basic requirements 7.15.3 Test article configuration 7.15.4 Monitoring during test 7.15.5 Test levels and duration |
85 | 7.15.6 Test condition and guidelines 7.15.7 Tailoring guide 7.16 Shock test 7.16.1 Purpose of test 7.16.2 Test facilities and set-up as basic requirements 7.16.3 Test article configuration 7.16.4 Monitoring during test 7.16.5 Test levels and duration 7.16.6 Test condition and guidelines 7.16.7 Tailoring guide |
86 | 7.17 Thermal balance test 7.17.1 Purpose of test 7.17.2 Test facilities and set-up as basic requirements 7.17.3 Test article configuration 7.17.4 Monitoring during test 7.17.5 Test levels and duration 7.17.6 Test condition and guidelines 7.17.7 Tailoring guide |
87 | 7.18 Thermal vacuum test 7.18.1 Purpose of test 7.18.2 Test facilities and set-up as basic requirements 7.18.3 Test article configuration 7.18.4 Monitoring during test 7.18.5 Test levels and duration |
88 | 7.18.6 Test condition and guidelines 7.18.7 Tailoring guide 7.19 Thermal cycle test 7.19.1 Purpose of test 7.19.2 Test facilities and set-up as basic requirements 7.19.3 Test article configuration 7.19.4 Monitoring during test 7.19.5 Test levels and duration 7.19.6 Test condition and guidelines |
89 | 7.19.7 Tailoring guide 7.20 Pressure test 7.20.1 Purpose of test 7.20.2 Test facilities and set-up as basic requirements 7.20.3 Test article configuration 7.20.4 Monitoring during test 7.20.5 Test levels and duration |
90 | 7.20.6 Test condition and guidelines 7.20.7 Tailoring guide 7.21 Leakage test 7.21.1 Purpose of test 7.21.2 Test facilities and set-up as basic requirements 7.21.3 Test article configuration 7.21.4 Monitoring during test 7.21.5 Test levels and duration 7.21.6 Test condition and guidelines 7.21.7 Tailoring guide |
91 | 7.22 Burn-in and wear-in test 7.22.1 Purpose of test 7.22.2 Test facilities and set-up as basic requirements 7.22.3 Test article configuration 7.22.4 Monitoring during test 7.22.5 Test levels and duration 7.22.6 Test condition and guidelines 7.22.7 Tailoring guide 7.23 Tracking and control system/spacecraft compatibility test 7.23.1 Purpose of test |
92 | 7.23.2 Test facilities and set-up as basic requirements 7.23.3 Test article configuration 7.23.4 Monitoring during test 7.23.5 Test levels and duration 7.23.6 Test condition and guidelines 7.23.7 Tailoring guide |