BS ISO 17123-9:2018
$198.66
Optics and optical instruments. Field procedures for testing geodetic and surveying instruments – Terrestrial laser scanners
Published By | Publication Date | Number of Pages |
BSI | 2018 | 52 |
This document specifies field procedures for determining and evaluating the precision (repeatability) of terrestrial laser scanners and their ancillary equipment when used in building, civil engineering and surveying measurements. Primarily, these tests are intended to be field verifications of the suitability of a particular instrument for the immediate task at hand, and to satisfy the requirements of other standards. They are not proposed as tests for acceptance or performance evaluations that are more comprehensive in nature.
This document can be thought of as one of the first steps in the process of evaluating the uncertainty of measurements (more specifically of measurands).
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
6 | Foreword |
7 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
10 | 4 Symbols and subscripts 4.1 Symbols |
11 | 4.2 Subscripts 5 Requirements and recommendations |
12 | 6 Test principle 6.1 General 6.2 Procedure 1: Simplified test procedure 6.3 Procedure 2: Full test procedure |
13 | 7 Simplified test procedure 7.1 Configuration of the test field |
15 | 7.2 Example 1: Target scan by full dome scan |
17 | 7.3 Example 2: Two face target scan 7.4 Measurements 7.5 Calculation |
20 | 7.6 Derivation of a reference quantity for computing permitted deviations 7.6.1 Introduction 7.6.2 Determination of measurement uncertainty of the target centers |
21 | 7.6.3 Derivation of the permitted deviation for the simple test procedure 7.7 Quantification of measurement deviations and judgement of the instrument for the simple test procedure 7.7.1 Analysis of distance measurements |
22 | 7.7.2 Remarks on the scale problem 7.7.3 Analysis of further distance differences |
24 | 8 Full test procedure 8.1 Configuration of the test field |
25 | 8.2 Measurements |
26 | 8.3 Calculation |
29 | 8.4 Statistical tests 8.4.1 General description |
30 | 8.4.2 Question a) 8.4.3 Question b) |
31 | 8.5 Derivation of a reference quantity for computing permitted deviation 8.5.1 Determination of measurement uncertainty of the target centre 8.5.2 Derivation of the permitted deviation for the full test procedure |
32 | 8.6 Quantification of measurement deviations and judgement of the instrument for the full test procedure |
34 | Annex A (informative) Example for the simplified test procedure |
36 | Annex B (informative) Example for the full test procedure |
44 | Annex C (normative) Example for the calculation of an uncertainty budget of Type B |
51 | Bibliography |