BS ISO 18326:2018+A1:2021
$198.66
Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance
Published By | Publication Date | Number of Pages |
BSI | 2021 | 60 |
This document specifies the standard conditions for capacity and efficiency ratings of non-ducted portable air-cooled air conditioners having a single exhaust duct and non-ducted portable air-cooled heat pumps having a single exhaust duct. Such air conditioners and heat pumps may include an evaporatively cooled condenser cooled by air and the evaporation of:
-
condensate collected from the evaporator;
-
external supplementary water stored in a supplementary water tank; or
-
both a) and b).
This document also specifies the test methods for determining the capacity and efficiency ratings.
This document applies to equipment that is factory-made, electrically driven and uses mechanical compression. This document is applicable to equipment utilizing one or more refrigeration systems.
This document is not applicable to the rating and testing of the following:
-
Water-source heat pumps or water-cooled air conditioners;
-
Multi-split-system air conditioners and air-to-air heat pumps (see ISO 15042:2017 for the testing of such equipment);
-
Individual assemblies not constituting a complete refrigeration system;
-
Equipment using the absorption refrigeration cycle;
-
Ducted equipment (see ISO 13253:2017 for the testing of such equipment);
-
Evaporative coolers or any other cooling systems that are not of the vapour compression type;
-
Dehumidifiers;
-
Spot coolers.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | National foreword |
7 | Foreword |
8 | Introduction |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
13 | 4 Symbols |
15 | 5 Cooling tests 5.1 Cooling capacity test 5.1.1 General conditions 5.1.2 Condensate containers 5.1.3 Tests using supplementary water evaporation feature |
16 | 5.1.4 Temperature conditions |
17 | 5.1.5 Airflow conditions — Air quantity 5.1.6 Test conditions 5.2 Maximum cooling performance test 5.2.1 General conditions 5.2.2 Temperature conditions |
18 | 5.2.3 Temperature conditions 5.2.4 Performance requirements |
19 | 5.3 Condensate control and enclosure sweat performance test 5.3.1 General conditions 5.3.2 Temperature conditions 5.3.3 Airflow conditions 5.3.4 Test conditions 5.3.5 Performance requirements |
20 | 6 Heating tests 6.1 Heating capacity tests 6.1.1 General conditions |
21 | 6.1.2 Temperature conditions 6.1.3 Airflow conditions — Air quantity 6.1.4 Test conditions |
22 | 6.2 Maximum heating performance test 6.2.1 General conditions 6.2.2 Temperature conditions 6.2.3 Airflow conditions 6.2.4 Test conditions |
23 | 7 Test methods and uncertainties of measurements 7.1 Test methods 7.1.1 General 7.1.2 Calorimeter test method 7.1.3 Capacity tests 7.2 Uncertainties of measurement 7.3 Test tolerances for steady-state cooling and heating tests 7.3.1 Variation of individual observations |
24 | 7.3.2 Variation of average observations 7.3.3 Sampling rate 7.3.4 Tolerances for capacity calculations |
25 | 7.4 Test tolerances for performance tests 8 Test capacity results 8.1 Capacity results 8.1.1 General 8.1.2 Adjustments 8.1.3 Cooling capacity calculations |
26 | 8.1.4 Heating capacity calculations 8.2 Data to be recorded 8.3 Test report 8.3.1 General information |
28 | 8.3.2 Capacity tests 9 Marking provisions 9.1 Nameplate requirements 9.2 Nameplate information 9.3 Literature requirements |
29 | 10 Publication of ratings 10.1 Standard ratings 10.1.1 General 10.1.2 Units 10.1.3 EER and COP 10.1.4 Capacity rating and test voltage 10.2 Other ratings |
30 | Annex A (normative) Test requirements |
34 | Annex B (normative) Units with a supplementary water-tank — Determining the duration of supplementary water evaporation feature |
36 | Annex C (informative) Airflow measurement |
42 | Annex D (normative) Calorimeter test method |
52 | Annex E (informative) Cooling condensate measurements |
53 | Annex F (informative) Example of multiple point air sampling apparatus |
55 | Annex G (normative) Information on installation and use |
59 | Bibliography |