BS ISO 18326:2018+A1:2021

$198.66

Non-ducted portable air-cooled air conditioners and air-to-air heat pumps having a single exhaust duct. Testing and rating for performance

Published By Publication Date Number of Pages
BSI 2021 60
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies the standard conditions for capacity and efficiency ratings of non-ducted portable air-cooled air conditioners having a single exhaust duct and non-ducted portable air-cooled heat pumps having a single exhaust duct. Such air conditioners and heat pumps may include an evaporatively cooled condenser cooled by air and the evaporation of:

  1. condensate collected from the evaporator;

  2. external supplementary water stored in a supplementary water tank; or

  3. both a) and b).

This document also specifies the test methods for determining the capacity and efficiency ratings.

This document applies to equipment that is factory-made, electrically driven and uses mechanical compression. This document is applicable to equipment utilizing one or more refrigeration systems.

This document is not applicable to the rating and testing of the following:

  1. Water-source heat pumps or water-cooled air conditioners;

  2. Multi-split-system air conditioners and air-to-air heat pumps (see ISO 15042:2017 for the testing of such equipment);

  3. Individual assemblies not constituting a complete refrigeration system;

  4. Equipment using the absorption refrigeration cycle;

  5. Ducted equipment (see ISO 13253:2017 for the testing of such equipment);

  6. Evaporative coolers or any other cooling systems that are not of the vapour compression type;

  7. Dehumidifiers;

  8. Spot coolers.

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 Foreword
8 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
13 4 Symbols
15 5 Cooling tests
5.1 Cooling capacity test
5.1.1 General conditions
5.1.2 Condensate containers
5.1.3 Tests using supplementary water evaporation feature
16 5.1.4 Temperature conditions
17 5.1.5 Airflow conditions — Air quantity
5.1.6 Test conditions
5.2 Maximum cooling performance test
5.2.1 General conditions
5.2.2 Temperature conditions
18 5.2.3 Temperature conditions
5.2.4 Performance requirements
19 5.3 Condensate control and enclosure sweat performance test
5.3.1 General conditions
5.3.2 Temperature conditions
5.3.3 Airflow conditions
5.3.4 Test conditions
5.3.5 Performance requirements
20 6 Heating tests
6.1 Heating capacity tests
6.1.1 General conditions
21 6.1.2 Temperature conditions
6.1.3 Airflow conditions — Air quantity
6.1.4 Test conditions
22 6.2 Maximum heating performance test
6.2.1 General conditions
6.2.2 Temperature conditions
6.2.3 Airflow conditions
6.2.4 Test conditions
23 7 Test methods and uncertainties of measurements
7.1 Test methods
7.1.1 General
7.1.2 Calorimeter test method
7.1.3 Capacity tests
7.2 Uncertainties of measurement
7.3 Test tolerances for steady-state cooling and heating tests
7.3.1 Variation of individual observations
24 7.3.2 Variation of average observations
7.3.3 Sampling rate
7.3.4 Tolerances for capacity calculations
25 7.4 Test tolerances for performance tests
8 Test capacity results
8.1 Capacity results
8.1.1 General
8.1.2 Adjustments
8.1.3 Cooling capacity calculations
26 8.1.4 Heating capacity calculations
8.2 Data to be recorded
8.3 Test report
8.3.1 General information
28 8.3.2 Capacity tests
9 Marking provisions
9.1 Nameplate requirements
9.2 Nameplate information
9.3 Literature requirements
29 10 Publication of ratings
10.1 Standard ratings
10.1.1 General
10.1.2 Units
10.1.3 EER and COP
10.1.4 Capacity rating and test voltage
10.2 Other ratings
30 Annex A (normative) Test requirements
34 Annex B (normative) Units with a supplementary water-tank — Determining the duration of supplementary water evaporation feature
36 Annex C (informative) Airflow measurement
42 Annex D (normative) Calorimeter test method
52 Annex E (informative) Cooling condensate measurements
53 Annex F (informative) Example of multiple point air sampling apparatus
55 Annex G (normative) Information on installation and use
59 Bibliography
BS ISO 18326:2018+A1:2021