Shopping Cart

No products in the cart.

BS ISO 22192:2021

$198.66

Bunkering of marine fuel using the Coriolis mass flow meter (MFM) system

Published By Publication Date Number of Pages
BSI 2021 58
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document specifies procedures and requirements for the transfer of bunkers to vessels by bunker tankers using the Coriolis mass flow meter (MFM) system. It encompasses the process leading to the approval of the MFM system as installed on bunker tankers and post-approval bunkering operation. It covers terminology, specifications, requirements and procedures on metrology, system integrity, metering system selection and installation, MFM system verification, bunker delivery and dispute handling.

NOTE

Local and international regulations, such as the International Convention for the Prevention of Pollution from Ships (MARPOL) can apply.

PDF Catalog

PDF Pages PDF Title
2 National foreword
7 Foreword
8 Introduction
9 1 Scope
2 Normative references
3 Terms and definitions
15 4 General requirements (safety, health and the environment)
5 Metrological requirements
5.1 General
5.2 Mass flow meter requirement
16 5.3 Mass flow meter system requirements
17 5.4 Post approval maintenance
5.4.1 Meter zero verification frequency
5.4.2 Zero verification procedure
5.4.3 Meter and ancillary devices verification and/or calibration frequency
5.4.4 Software upgrade/ software update
18 6 System integrity requirements
6.1 General
6.2 Metrological control
6.2.1 Documentation
6.2.2 Type approval and pattern evaluation
6.3 Security features
6.3.1 Equipment security
6.3.2 Software security
19 6.3.3 Data security
6.3.4 Critical alarm
6.4 Installation and commissioning
6.4.1 Pre-installation and MFM system sealing plan
6.4.2 Installation and re-installation
6.4.3 Commissioning
20 6.4.4 Re-commissioning
6.5 Operational security
6.6 Maintenance and control of MFM system
6.6.1 Inspection and verification
6.6.2 Breaking of seals and re-sealing of MFM system
7 Meter selection and installation requirements
7.1 General
21 7.2 Site survey onboard tankers
7.3 Meter selection
7.4 Meter installation
22 7.5 Meter commissioning
8 MFM system verification requirements
9 Metering procedures
9.1 General
9.2 Documentation
9.2.1 General
23 9.2.2 Pre-delivery documentation
9.2.3 Post-delivery documentation
9.3 Additional documentation for bunker surveyor
24 9.3.3 Survey time log and statement of facts
9.4 Additional documentation for bunker tanker
9.4.1 Meter totalizer log
9.4.2 Documents carried onboard the bunker tanker
25 9.5 ​Planning for bunkering operation
9.6 Pre-delivery procedures
9.6.1 Flow measurement conditions and checks on system integrity
9.6.2 Pre-delivery conference
9.6.3 Bunker requisition form (mass flow metering)
26 9.6.4 Mass flow metering system seals checklist
9.6.5 Meter reading record form (delivery)
27 9.7 Delivery procedures
9.7.1 General
9.7.2 Start of delivery
28 9.7.3 End of delivery
29 9.8 Post-delivery procedures and checks
9.8.1 Meter reading record form (delivery)
9.8.2 Mass flow metering system seals checklist
9.8.3 Bunker metering ticket
9.8.4 Bunker delivery note
30 9.8.5 Custody transfer quantity
31 9.9 Others
9.9.1 MFM system failure
9.9.2 Quantity dispute
10 Sampling
32 Bibliography
33 Annex A (informative) Safety, health and the environment
37 Annex B (informative) Uncertainty budget table
38 Annex C (informative) Metrological and system integrity requirements
39 Annex D (informative) Procedures for zero verification
40 Annex E (informative) Sealable bolts and nuts for blanks and ancillary device
42 Annex F (informative) Request for information checklist
44 Annex G (informative) Typical schematic diagram for MFM system (for delivery)
45 Annex H (normative) Example of bunker requisition form (mass flow metering)
46 Annex I (informative) Example of mass flow metering system seals checklist
47 Annex J (informative) Example of meter reading record form (delivery)
48 Annex K (informative) Example of bunker metering ticket
49 Annex L (informative) Bunkering pre-delivery safety checklist
52 Annex M (informative) Example of survey time log
54 Annex O (informative) Example of meter totalizer log
56 Annex P (informative) Example of letter of protest
57 Annex Q (informative) Quantity dispute procedures and documents
BS ISO 22192:2021
$198.66