BS EN 60364-5-53. Low-voltage electrical installations. Part 5-53. Selection and erection of electrical equipment. Switchgear and control gear

Published By Publication Date Number of Pages
BSI 2013 26
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
8 530 Introduction
530.1 Scope
530.2 Normative references
530.3 Terms and definitions
530.4 General and common requirements
9 530.5 Fixing of equipment
531 Devices for protection against electric shock by automatic disconnection of supply
531.1 General
10 531.2 Overcurrent protective devices
531.2.1 TN systems
531.2.2 TT systems
531.2.3 IT systems
11 531.3 Residual current protective devices (RCD)
531.3.1 General conditions of installation
531.3.1.4 Avoidance of unwanted tripping
531.3.1.5 Types of RCDs
12 531.3.2 Selection of devices according to the capability of the users of the installation
531.3.3 Selection and erection of RCDs for fault protection
531.3.3.1 TN system
13 531.3.3.2 TT system
531.3.3.2.1 Location of RCD’s
531.3.3.2.2 Selection of the rated residual operating current of the RCD
531.3.3.3 IT system
14 531.3.3.3.1 Case of second fault when exposed-conductive-parts are interconnected
531.3.3.3.2 Case of second fault when exposed-conductive-parts are not interconnected
531.3.4 Additional protection
15 532 Devices for protection against the risk of fire
532.1 General
532.2 Residual current protective devices (RCDs) for protection against the risk of fire
532.3 Residual current monitoring devices (RCMs) for protection against the risk of fire
532.4 Insulation monitoring devices (IMDs) for protection against the risk of fire
16 532.5 Interfering arc protective devices
532.6 Arc fault detection devices (AFDD)
533 Devices for protection against overcurrent
17 533.1 General requirements
533.1.1 General requirements for fuses
533.1.2 General requirements for circuit-breakers
533.2 Selection of devices for overload protection of wiring systems
18 533.2.1 Additional requirements against overload with the presence of harmonic currents
533.3 Selection of devices for protection of wiring systems against short circuits
533.3.1 Short-circuit breaking capacity
533.3.2 Breaking time
20 534 Devices for protection against overvoltages
535 Devices for protection against undervoltage
21 536 Coordination of protective devices
537 Isolation and switching
538 Monitoring devices
538.1 Insulation monitoring devices for IT systems (IMDs)
538.1.1 General
22 538.1.2 Installation of insulation monitoring devices (IMDs)
538.1.3 Adjustment of the insulation monitoring device (IMD)
23 538.1.4 Passive insulation monitoring devices
538.2 Equipment for insulation fault location in IT systems
538.3 Monitoring of off-line circuits
538.4 Residual current monitor (RCM)
25 Annex A (informative) Possible fault currents in systems with semiconductors