BSI 16/30328492 DC:2016 Edition
$13.70
BS IEC 80005-3. Utility connections in port. Part 3. Low Voltage Shore Connection (LVSC) Systems. General requirements
Published By | Publication Date | Number of Pages |
BSI | 2016 | 52 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
12 | 1 Scope 2 Normative references |
13 | 3 Terms and definitions 3.1 cable management system 3.2 plug and socket-outlet |
14 | 3.2.1 socket-outlet 3.2.2 plug 3.3 ship coupler 3.3.1 ship connector 3.3.2 ship inlet |
15 | 4 General requirements 4.1 System description |
16 | 4.2 Distribution system 4.2.1 General 4.2.2 Equipotential bonding |
17 | 4.3 Compatibility assessment before connection 4.4 LVSC system design and operation 4.4.1 System design 4.4.2 System operation |
18 | 4.5 Personnel safety 4.6 Design requirements 4.6.1 General 4.6.2 Protection against moisture and condensation 4.6.3 Location and construction |
19 | 4.6.4 Electrical equipment in hazardous areas 4.7 Electrical requirements 4.8 System study and calculations |
20 | 4.9 Emergency shutdown including emergency-stop facilities |
21 | 5 LV shore supply system requirements 5.1 Voltages and frequencies |
22 | 5.2 Quality of LV shore supply |
23 | 6 Shore-side installation 6.1 General 6.2 System component requirements 6.2.1 Circuit-breaker and disconnector |
24 | 6.2.2 Transformer 6.2.3 Neutral earthing resistor 6.2.4 Equipment earthing conductor bonding 6.3 Shore-to-ship electrical protection system |
25 | 6.4 LV interlocking 6.4.1 General 6.4.2 Operating of the low-voltage (LV) circuit-breakers and disconnectors |
26 | 6.5 Shore connection convertor equipment 6.5.1 General 6.5.2 Degree of protection 6.5.3 Cooling 6.5.4 Protection |
27 | 7 Ship-to-shore connection and interface equipment 7.1 General 7.2 Cable management system 7.2.1 General |
28 | 7.2.2 Monitoring of cable tension |
29 | 7.2.3 Monitoring of the cable length 7.3 Plugs and socket-outlets and ship couplers 7.3.1 General |
31 | 7.3.2 Pilot contacts 7.4 Ship-to-shore connection cable |
32 | 7.5 Independent control and monitoring cable 7.6 Storage 8 Ship requirements 8.1 General 8.2 Ship electrical distribution system protection 8.2.1 Short-circuit protection 8.2.2 Earth fault protection, monitoring and alarm 8.3 Shore connection switchboard 8.3.1 General |
33 | 8.3.2 Circuit-breaker and disconnector 8.3.3 Instrumentation and protection 8.4 On-board transformer |
34 | 8.5 On-board receiving switchboard connection point 8.5.1 General 8.5.2 Circuit-breaker 8.5.3 Instrumentation |
35 | 8.5.4 Protection |
36 | 8.5.5 Operation of the circuit-breaker 8.6 Ship power restoration 9 LVSC system control and monitoring 9.1 General requirements |
37 | 9.2 Load transfer via blackout 9.3 Load transfer via automatic synchronization 9.3.1 General 9.3.2 Protection requirements |
38 | 10 Verification and testing 10.1 General 10.2 Initial tests of shore-side installation 10.2.1 General 10.2.2 Tests 10.3 Initial tests of ship-side installation 10.3.1 General |
39 | 10.3.2 Tests 10.4 Tests at the first call at a shore supply point 10.4.1 General 10.4.2 Tests |
40 | 11 Periodic tests and maintenance 11.1 General 11.2 Tests at repeated calls of a shore supply point 11.2.1 General 11.2.2 Verification 12 Documentation 12.1 General 12.2 System description |
41 | Annex A (Informative) Ship-to-shore connection cable1F A.1 Rated voltage A.2 Rated cross section / type A.3 General design A.3.1 General A.3.2 Conductors |
42 | A.3.3 Earth conductors A.3.4 Pilot elements |
43 | Annex B (normative) Additional requirements for Offshore Supply, Service and Working Ships B.1 Scope B.4.1 System description |
44 | B.4.3 Compatibility assessment before connection m) sufficient cable length to reach the receiving point level plus 3 meters. B.7.2.1 General B.7.3.1 General |
45 | Annex C (normative) Additional requirements for Container Ships C.1 Scope C.4.1 System description |
46 | C.4.3 Compatibility assessment before connection m) sufficient cable length to reach the supply point level plus 3 meters. C.7.2.1 General C.7.3.1 General |
47 | Annex D (informative) Additional requirements for Tankers D.1 Scope D.4.1 System description D.4.3 Compatibility assessment before connection m) sufficient cable length to reach the receiving point level plus 3 meters. |
48 | D.4.9 Emergency shutdown including emergency-stop facilities D.5.1 Voltages and frequencies D.6.2.3 Neutral earthing resistor D.7.2.1 General D.7.3.1 General |
50 | Annex E (normative) General operating procedures |
51 | Annex F Bibliography |