Shopping Cart

No products in the cart.

BSI 16/30338243 DC:2016 Edition

$13.70

BS EN 1457-2. Chimneys. Clay/ceramic flue liners. Part 2. Flue liners operating under wet conditions. Requirements and test methods

Published By Publication Date Number of Pages
BSI 2016 64
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
4 Contents Page
9 1 Scope
2 Normative references
10 3 Terms and definitions
11 4 Flue liners and openings
4.1 Flue liner cross-sections
12 4.2 Inspection openings and chimney junctions
13 5 Types of flue liner
14 6 Materials
7 Tolerances on dimensions
7.1 Transverse dimension
7.2 Height
7.3 Angle of curvature
7.4 Straightness
7.5 Squareness of ends
7.6 Deviation from shape of cross section
7.7 Geometry of joints
15 8 Proof load
8.1 Straight flue liners
8.2 Curved flue liners
8.3 Minimum load for inspection opening sections
9 Gas tightness/leakage, thermal shock resistance and soot fire resistance for straight flue liners
9.1 Initial test
16 9.2 Gas tightness
9.2.1 General
9.2.2 Gas tightness after sootfire testing
9.2.3 Gas tightness after thermal shock testing
17 10 Durability
10.1 Corrosion resistance
10.2 Freeze/Thaw resistance
11 Water absorption and bulk density
11.1 General
11.2 Water absorption
11.3 Bulk density
12 Abrasion resistance
13 Condensate resistance and flow resistance
13.1 Condensate resistance
18 13.2 Flow resistance
14 Thermal resistance
15 Assessment and verification of constancy of performance – AVCP
15.1 General
15.2 Type testing
15.2.1 General
19 15.2.2 Test samples, testing and compliance criteria
20 15.2.3 Test reports
21 15.2.4 Shared other party results
15.2.5 Cascading determination of the product type results
22 15.3 Factory production control (FPC)
15.3.1 General
23 15.3.2 Requirements
15.3.2.1 General
24 15.3.2.2 Equipment
15.3.2.3 Raw materials and components
15.3.2.4 Traceability and marking
15.3.2.5 Controls during manufacturing process
15.3.2.6 Product testing and evaluation
26 15.3.2.7 Non-complying products
15.3.2.8 Corrective action
15.3.2.9 Handling, storage and packaging
15.3.3 Product specific requirements
27 15.3.4 Initial inspection of factory and of FPC
15.3.5 Continuous surveillance of FPC
15.3.6 Procedure for modifications
28 15.3.7 One-off products, pre-production products (e.g. prototypes) and products produced in very low quantity
29 16 Test methods
16.1 Size
16.2 Height
16.3 Angle of curvature
30 16.4 Straightness
16.5 Squareness of ends
31 16.6 Deviation from shape of cross-section
33 16.7 Proof load
16.7.1 Test specimen
16.7.2 Testing equipment
16.7.3 Test procedure
34 16.8 Thermal testing
16.8.1 Test flue
16.8.2 Test equipment
36 16.8.3 Assembly of test flue
16.8.4 Thermal conditioning
37 16.8.5 Measurement of leakage rate
16.8.6 Expression of results
38 16.9 Corrosion resistance
16.9.1 Test specimens
16.9.2 Test equipment
16.9.3 Test procedure
39 16.9.4 Expression of results
16.10 Water absorption
16.10.1 Test specimen
16.10.2 Test equipment
16.10.3 Test procedure
16.10.4 Expression of results
40 16.11 Bulk density
16.11.1 Test specimen
16.11.2 Test equipment
16.11.3 Test procedure
16.11.4 Expression of results
16.12 Abrasion resistance
16.12.1 Test flue
41 16.12.2 Test equipment
16.12.3 Test procedure
16.12.4 Expression of results
42 16.13 Test method for the determination of water and vapour flow (indirect method)
16.13.1 Test installation
43 16.13.2 Test sample
16.13.3 Position of measuring points and records
16.13.3.1 General
16.13.3.2 Ventilated air in the test sample
16.13.3.3 Test sample
16.13.3.4 Humidity in the test equipment
44 16.13.3.5 Testroom
16.13.3.6 Description of the test sample
16.13.4 Test procedure
16.13.4.1 Drying phase
16.13.4.2 Temperature and humidity demand for the test sample, test Figure 11
16.13.4.3 Characteristic values of the test sample
45 16.13.5 Results
16.13.6 Measuring equipment — Composition, measuring range, uncertainty
46 16.13.7 Test rig
47 17 Designation
18 Marking
48 19 Release of dangerous substances
49 Annex A (normative)Sampling procedures for an AQL of 10 % and inspection level S2
A.1 Acceptability determination
A.1.1 Single sampling
A.1.2 Double sampling
A.2 Normal inspection
51 A.3 Normal to reduced inspection
A.4 Reduced to normal inspection
A.5 Tightened inspection
52 A.6 Tightened to normal inspection
A.7 Discontinuation of inspection
53 Annex B (normative)Thermal resistance
B.1 Method 1: simplified calculation for flue liners without cavities
B.2 Method 2: thermal resistance of flue liners with or without cavities
B.2.1 General
54 B.2.2 Data
B.2.2.1 Thermal properties of the material
55 B.2.2.2 Boundary conditions
B.2.3 Specific conditions for the cavities
B.2.3.1 General
56 B.2.3.2 Heat transmitted by conduction-convection in the air
57 B.2.3.3 Heat transmitted by radiation
B.2.3.4 Equivalent thermal conductivity
58 B.2.4 Calculations
B.2.4.1 General
B.2.4.2 Numerical resolution
B.3 Method Approximate thermal resistance values
59 Annex C (normative)Measurement of the coefficient of friction of chimneys
61 Annex ZA (informative)Relationship of this European Standard with Regulation (EU) No.305/2011
BSI 16/30338243 DC
$13.70