Shopping Cart

No products in the cart.

BSI 20/30411023 DC:2020 Edition

$13.70

BS EN IEC 62271-112. High-voltage switchgear and controlgear – Part 112. Alternating current high-speed earthing switches for secondary arc extinction on transmission lines

Published By Publication Date Number of Pages
BSI 2020 29
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

PDF Catalog

PDF Pages PDF Title
1 30411023
3 17A_1257e_CD
4 CONTENTS
6 FOREWORD
8 1 Scope
2 Normative references
3 Terms and definitions
3.1 General terms
10 3.2 Assemblies of switchgear and controlgear
3.3 Parts of assemblies
3.4 Switching devices
3.5 Parts of switchgear and controlgear
3.6 Operation
3.7 Characteristics quantities
4 Normal and special service conditions
11 5 Ratings
5.1 General
5.5 Rated continuous current (Ir)
5.101 Rated short-circuit making current
5.102 Rated operating sequence
12 6 Design and construction
6.1. General
6.5 Dependent power operation
6.7 Independent unlatched operation (independent manual or power operation)
11 Nameplates
13 6.12 Locking devices
6.101 Anti-pumping device
6.102 Special requirements for HSES
14 7 Type tests
7.1. General
7.3 Radio interference voltage (RIV) test
7.5 Continuous current tests
7.101 Tests to prove the short-circuit making performance
7.102 Operating and mechanical endurance tests
7.103 Operation under severe ice condition
7.104 Operation at the temperature limits
7.105 Tests to prove the making and breaking performance of HSES
7.105.1 General test conditions
15 7.105.2 Induced current switching details
16 7.105.3 Arrangement of HSES before the test
7.105.4 Behaviour of HSES during the test
7.105.5 Condition after the test
8 Routine tests
17 9 Guide to the selection of HSES
10 Information to be given with enquiries, tenders and orders
11 Rules for transport, storage, installation, operation and maintenance
12 Safety
18 Annex A (informative) Background information on the use of HSES
A.1 General
A.2 Typical operating sequence
21 A.3 Additional information about HSES
A.4 Comparison between the use of four-legged reactor and HSES
23 Annex B (informative) Induced current and voltage conditions for other cases
B.1 General
B.2 Categories of fault conditions
B.2.1 Category 0
B.2.2 Category 1
B.2.3 Category 2
B.2.4 Category 3
B.2.5 Category 4
24 B.3 Delayed current zero phenomena
B.3.1 Explanation of an occurrence of delayed current zero phenomena
26 B.3.2 Preferred values for single-phase earth fault with delayed current zero phenomena in the presence of a successive fault
28 B.4 Preferred values of currents and voltages for multi-phase re-closing scheme
B.5 Interrupting condition to cover the cases corresponding to categories 0 and 1
BSI 20/30411023 DC