BSI 20/30419189 DC:2020 Edition
$13.70
BS EN IEC 60809. Lamps and light sources for road vehicles. Dimensional, electrical and luminous requirements
Published By | Publication Date | Number of Pages |
BSI | 2020 | 97 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | CONTENTS |
10 | FOREWORD |
13 | 1 Scope 2 Normative references |
15 | 3 Terms and definitions |
18 | 4 Requirements and test conditions for filament lamps 4.1 General requirements 4.2 Lamp marking |
19 | 4.3 Bulbs 4.4 Colour 4.4.1 Colour of light |
20 | 4.4.2 Colour endurance |
21 | 4.4.3 Coated bulb 4.5 Lamp dimensions 4.6 Caps and bases 4.7 Initial electrical and luminous requirements 4.8 Check on optical quality 4.8.1 General 4.8.2 12 V lamps emitting white light |
22 | 4.8.3 6 V and 24 V lamps emitting white light 4.8.4 Lamps emitting selective-yellow light 4.9 UV radiation 4.10 Standard (étalon) filament lamps |
23 | 4.11 Non-replaceable filament lamps 4.11.1 General 4.11.2 Fixation |
24 | 4.11.3 Lifetime 4.11.4 Colour endurance 4.11.5 Luminous flux and colour maintenance |
25 | 4.11.6 Vibration and shock resistance 5 Requirements and test conditions for discharge lamps 5.1 General requirements 5.2 Lamp marking 5.3 Bulbs |
26 | 5.4 Caps 5.5 Position and dimensions of electrodes, arc and black stripes 5.5.1 Measurements 5.5.2 Electrodes 5.5.3 Arc 5.5.4 Black stripes 5.6 Starting, run-up and hot-restrike characteristics 5.6.1 Starting 5.6.2 Run-up 5.6.2.1 Lamps 2 000 lm |
27 | 5.6.2.2 Lamps 2 000 lm without black stripes 5.6.2.3 Lamps ≤ 2 000 lm with black stripes 5.6.2.4 Lamps with more than one rated value, and one of them ≤ 2 000 lm 5.6.3 Hot-restrike 5.6.4 Compliance 5.7 Electrical and photometric characteristics 5.7.1 Voltage and wattage 5.7.2 Luminous flux 5.7.3 Compliance |
28 | 5.8 Colour 5.9 UV radiation |
29 | 5.10 Standard (étalon) discharge lamps 6 Requirements and test conditions for LED light sources 6.1 General requirements 6.2 Light source marking |
30 | 6.3 Optical surfaces 6.4 Colour of light 6.5 Lamp dimensions |
31 | 6.6 Caps and bases 6.7 Initial electrical and photometrical requirements 6.8 Red content 6.9 UV radiation 6.10 Standard (étalon) light sources |
32 | 7 Sampling and conditions of compliance 8 Lamp data sheets 8.1 General 8.2 List of specific lamp types |
37 | 8.3 Datasheets not transferred to UN R.E.5 |
58 | Annex A (normative) Filament shape, length and position A.1 General A.2 Filaments shown as points A.3 Line filaments A.4 Coiled-coil filaments A.5 Extreme filament turns A.6 Filament extremities A.6.1 General A.6.2 Axial filaments A.6.3 Transverse filaments |
59 | A.7 Determination of filament length A.8 Filament offsets A.9 Lateral deviation A.10 Filament location check system (box system) |
62 | Annex B (normative) Measurement method of the colour of filament lamps B.1 General B.2 Colour B.3 Measuring directions B.3.1 General B.3.2 Filament lamps used in headlamps |
63 | B.3.3 Filament lamps used in light signalling devices |
64 | Annex C (normative) Test conditions for electrical and luminous characteristics C.1 Filament lamps C.1.1 Ageing C.1.2 Test conditions C.1.3 Electrical instrumentation C.1.4 Photometry C.2 LED light sources C.2.1 Test conditions C.2.2 Luminous flux |
65 | C.2.3 Normalized luminous intensity C.2.4 Colour C.2.5 Power consumption C.2.6 Luminous flux and colour at elevated temperature C.2.6.1 General C.2.6.2 Measurement set-up and calibration |
67 | C.2.6.3 Measurement C.2.6.4 Alternative methods |
68 | Annex D (normative) Method of measuring internal elements of R2 lamps D.1 General test conditions D.1.1 Measurement position D.1.2 Ageing D.1.3 Test condition D.2 Reference axis, reference plane and planes for measurements D.2.1 Reference axis D.2.2 Reference plane D.2.3 Plane V-V D.2.4 Plane H-H D.2.5 Plane X-X D.2.6 Plane Y1-Y1 D.2.7 Plane Y2-Y2 |
69 | D.3 Viewing directions (see Figure D.1) D.3.1 Viewing direction ( D.3.2 Viewing direction ( D.3.3 Viewing direction ( D.4 Measuring points (MP) |
70 | D.5 Dimensions to be measured |
73 | Annex E (normative) Method of measuring internal elements of H4 and HS1 lamps E.1 General test conditions E.1.1 Measurement position E.1.2 Ageing E.1.3 Test condition E.2 Reference axis, reference plane and planes for measurements E.2.1 Reference axis E.2.2 Reference plane E.2.3 Plane V-V E.2.4 Plane H-H E.2.5 Plane X-X E.2.6 Plane Y1-Y1 |
74 | E.2.7 Plane Y2-Y2 E.2.8 Plane Y3-Y3 E.2.9 Plane Y4-Y4 E.2.10 Plane Y5-Y5 E.3 Viewing directions (see Figure E.1) E.3.1 Viewing direction ( E.3.2 Viewing direction ( E.3.3 Viewing direction ( E.3.4 Viewing direction E.4 Measuring points (MP) E.4.1 Shield and filaments (see Figure E.2) |
75 | E.4.2 Top obscuration (see Figure E.3) E.5 Dimensions to be measured |
80 | Annex F (normative) Method of measuring internal elements of HB1 lamps F.1 General test conditions F.1.1 Measurement position F.1.2 Ageing F.1.3 Test condition F.2 Dipped beam filament location F.2.1 Horizontal location F.2.2 Vertical location F.2.3 Axial location F.3 Main beam filament location F.3.1 Horizontal location F.3.2 Vertical location |
81 | F.3.3 Axial location |
82 | Annex G (informative) Optical set-up for the measurement of the position and form of the arc and of the position of the electrodes of discharge lamps |
83 | Annex H (normative) Measurement method of electrical and photometric characteristics of discharge lamps H.1 General H.2 Ballast H.3 Burning position H.4 Ageing H.5 Supply voltage H.6 Starting test H.7 Run-up test |
84 | H.8 Hot restrike test H.9 Electrical and photometric test H.10 Colour |
85 | Annex I (informative) Overview of lamp types and their applications |
88 | Annex J (normative) Test conditions for colour endurance measurements J.1 General J.2 Calibration and ageing |
89 | J.3 Test voltage J.4 Operating position J.5 Test rack J.6 Operating cycles |
92 | J.7 Closure |
93 | Annex K (informative) Method(s) to determine the value of the light centre length6F for Lx3A, Lx3B, Lx4A, Lx4B, Lx5A, Lx5B7F , L1A/6 and L1B/6 K.1 Measurement and calculation method based on ray tracing |
94 | K.2 Alternative method |
95 | Annex L (informative) Method to determine the maximum luminance gradient of LED light sources L.1 Measuring the luminance L.2 Calculating the maximum luminance gradient |
97 | Bibliography |