BS EN IEC 62909-3 Bi-directional grid connected power converters – Part 3. EMC requirements and test methods
Published By | Publication Date | Number of Pages |
BSI | 2023 | 56 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
8 | FOREWORD |
10 | INTRODUCTION |
11 | 1 Scope 2 Normative references |
13 | 3 Terms, definitions |
18 | 4 Classification of GCPCs 4.1 Division into classes |
19 | 4.2 Information for users 5 Measurement and test setup 5.1 General |
20 | 5.2 Configuration of test setups 5.2.1 General 5.2.2 Setups for immunity requirement test 5.2.2.1 General 5.2.2.2 Electrostatic discharge immunity test 5.2.2.3 Radiated, radio-frequency, electromagnetic field immunity test |
21 | 5.2.2.4 Electrical fast transient/burst immunity test 5.2.2.5 Surge immunity test 5.2.2.6 Immunity to conducted disturbances, induced by radio-frequency fields 5.2.2.7 Voltage dips, short interruptions and voltage variations immunity test (≤ 16 A) 5.2.2.8 Voltage dips, short interruptions and voltage variations immunity test (> 16 A) 5.2.3 Setups for low frequency emission requirement test 5.2.3.1 Harmonics 5.2.3.2 Voltage fluctuations and flicker 5.2.4 Setups for high frequency emission requirement test 6 Operating conditions during testing 6.1 General |
22 | 6.2 Operating conditions for immunity requirement test 6.2.1 Operating conditions for immunity requirement test for GCPC with EV section 6.3 Operating conditions for emission requirement test 6.3.1 Operating conditions for low frequency emission requirement test 6.3.2 Operating conditions for high frequency emission requirement test |
23 | 6.3.3 Operating conditions for emission requirement test for GCPC with EV section 7 Immunity requirements 7.1 General |
27 | 7.2 Performance criteria |
28 | 8 Emission requirements 8.1 Low frequency range |
29 | 8.2 High frequency range 8.2.1 Disturbance voltage limits at the AC power port (150 kHz to 30 MHz) |
30 | 8.2.2 Disturbance voltage limits at the DC power port (150 kHz to 30 MHz) |
31 | 8.2.3 Disturbance voltage limits at the CPT port (150 kHz to 30 MHz) |
32 | 8.2.4 Disturbance voltage limits at the wired network port and the signal and control port (150 kHz to 30 MHz) 8.2.5 Radiated emission limits at Enclosure port (above 30 MHz) |
33 | 8.2.5.1 GCPC with the EV section 8.2.5.2 GCPC without the EV section |
35 | 8.2.6 Radiated emission limits at Enclosure port (above 1 GHz) |
36 | 8.2.7 Radiated emission limits at Enclosure port (2kHz to 185kHz) with the EV section 8.2.8 Voltage transient disturbances with the EV section 9 Test results and test report |
37 | Annex A (informative) Examples of GCPC A.1 General A.2 Examples of GCPC within the scope of this document |
38 | A.3 Examples of GCPC where other standards apply |
40 | Annex B (informative) Overview of requirements B.1 General B.2 Immunity requirements |
41 | B.3 Conducted emission requirements B.4 Radiated emission requirements |
42 | Annex C (normative) Example test setups |
45 | Annex D (informative) Radiated disturbance test for keyless entry D.1 General D.2 Test setup D.3 Test method |
46 | D.4 Limits for radiated disturbances keyless entry (2 kHz to 185 kHz) |
47 | Annex E (informative) Termination of ports E.1 General E.2 Termination of communication lines – asymmetric artificial network (AAN) E.2.1 General E.2.2 Symmetric communication lines (e.g. CAN) |
48 | E.2.3 Coupling devices for PLC on power lines |
49 | E.2.4 PLC (technology) on control pilot |
51 | E.3 Coupling and termination devices for other communication and signalling lines |
52 | Annex F (normative) Voltage transient disturbances from DC charging equipment |
54 | Annex G (normative) Voltage surge test setup for DC charging EUT |
55 | Annex H (informative) Transient immunity test for DC charging EUT |
56 | Bibliography |