BSI 24/30493792 DC 2024
$13.70
BS EN IEC 60335-2-30 Household and similar electrical appliances. Safety – Part 2-30. Particular requirements for room heaters
Published By | Publication Date | Number of Pages |
BSI | 2024 | 45 |
PDF Catalog
PDF Pages | PDF Title |
---|---|
11 | 1 Scope |
12 | 2 Normative references 3 Terms and definitions |
14 | 4 General requirement 5 General conditions for the tests 5.101 Heaters intended to be used as both portable appliances and fixed appliances are subjected to the tests applicable to both types of appliances. 5.102 If the heater is a combination of two or more types, it is subjected to the tests relevant for each type, unless the tests for one type cover the other. |
15 | 6 Classification 7 Marking and instructions 7.1 Addition: |
18 | 7.14 Addition: |
19 | 7.15 Addition: 8 Protection against access to live parts |
20 | 9 Starting of motor-operated appliances 10 Power input and current 11 Heating |
22 | 11.3 Addition: 11.6 Replacement: 11.7 Replacement: Modification: Replace the first paragraph with the following: |
24 | 12 Charging of metal-ion batteries 13 Leakage current and electric strength at operating temperature |
25 | 14 Transient overvoltages 15 Moisture resistance 16 Leakage current and electric strength 17 Overload protection of transformers and associated circuits 18 Endurance 19 Abnormal operation |
30 | 20 Stability and mechanical hazards |
31 | 21 Mechanical strength 21.101 Visibly glowing radiant heaters, other than heaters for mounting at high level, are placed so that the central part of the fireguard is horizontal. A mass of 5 kg having a flat base 100 mm in diameter is placed for 1 min on the central part of … 21.102 Fixed appliances having a hinged part, the movement of which is restricted by chains or similar means, are fixed and the hinged part is allowed to drop under its own weight. This test is carried out five times. |
32 | 22 Construction |
33 | 22.101 Heaters, other than heaters for mounting at high level, shall be guarded in order to prevent contact with heating elements. |
34 | 22.102 Fireguards shall have a total open area not less than 50 % of the surface area of the fireguard. 22.104 Appliances for wall mounting shall be constructed so that they can be securely fixed to a wall. |
35 | 23 Internal wiring 24 Components |
36 | 24.1.4 Modification: Replace the third, fourth and fifth dashed item with the following: 25 Supply connection and external flexible cords |
37 | 26 Terminals for external conductors 27 Provision for earthing 28 Screws and connections 29 Clearances, creepage distances and solid insulation 30 Resistance to heat and fire 30.1 Addition: 30.2.1 Addition: 30.2.2 Not applicable. |
38 | 31 Resistance to rusting 32 Radiation, toxicity and similar hazards |
39 | Dimensions in millimetres Figure 101 – Examples of immediate surrounds of air-outlet grilles |
40 | Dimensions in millimetres Key A fireguard Figure 102 – Examples of the immediate surrounds of fireguards |
44 | Annex B (normative) Battery-operated appliances, separable batteries and detachable batteries for battery-operated appliances |