BSI PD CEN/TS 15502-3-1:2024

$198.66

Gas-fired central heating boilers – H2NG and ACCF. Expansion of EN 15502-2-1:2022

Published By Publication Date Number of Pages
BSI 2024 62
Guaranteed Safe Checkout
Categories: ,

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Scope of CEN/TS 15502-3-1 EN 15502-2-1:2022, Clause 1 applies with the following modifications: Add after k): l) which are fully premixed appliances equipped with an Adaptive Combustion Control Function (ACCF) that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance including gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20). m) which are fully premixed appliances equipped with a Pneumatic Gas Air Ratio controller (PGAR) that are intended to be connected to gas grids for natural gases of the second family where up to 20% hydrogen volume is added to the natural gas (H2NG-Y20), where the quality of the distributed gas without adding the hydrogen is not likely to vary to a large extent over the lifetime of the appliance. Replace ab) and ak) and al) by the following: ab) appliances that are intended to be connected to gas grids where the quality of the distributed gas is likely to vary to a large extent over the lifetime of the appliance (see Annex AB of EN 15502-1:2021), except for fully premixed appliances with a ACCF, as ACCF appliances are designed to adapt to variations in gas quality. ak) appliances that are intended to burn natural gases of the second family where hydrogen is added to the natural gas, except for fully premixed appliances with a ACCF or PGAR (which are covered by this document); al) Partially premixed appliances equipped with an adaptive combustion control function (ACCF).

PDF Catalog

PDF Pages PDF Title
2 undefined
9 1 Scope
2 Normative references
10 3 Terms and definitions
15 4 Classification
5 Construction
16 6 Electrical safety
7 Controls
8 Operational requirements
28 9 Useful efficiencies
29 10 Electric auxiliary energy
11 Risk assessment
12 Marking and instructions
32 Annex YA(normative)Specification of the normal operating conditions and settings for boilers having an ACCF
36 Annex YB(informative)Example of detailed information in the technical documentation for boilers having an ACCF
40 Annex YC(informative)Considerations on the use of limit gases for fully premixed ACCF and H2NG appliances
50 Annex YD(informative)Methods for generating a slope change of the Wobbe index
53 Annex YE(informative)Determination of the average CO level with an averaging time interval of 60 min
57 Annex YF(normative)Summary of the test conditions for fully premixed H2NG PGAR appliances and H2NG ACCF appliances