Information technology. Data centre facilities and infrastructures – Earthquake risk and impact analysis

Published By Publication Date Number of Pages
BSI 2021 26
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This document provides requirements and recommendations for the type of risk assessment to be employed concerning seismic activity and earthquakes in relation to data centres. In addition, it describes design concepts that can be employed as mitigation actions within the construction, and other elements of design, of data centres.

PDF Catalog

PDF Pages PDF Title
2 undefined
10 1 Scope
2 Normative references
3 Terms, definitions and abbreviations
3.1 Terms and definitions
11 3.2 Abbreviations
4 Availability Class of EN 506001
12 5 Overview of risk associated with seismic activity
5.1 Direct risk of seismic motion
5.1.1 Short-period ground motion
5.1.2 Long-period ground motion
5.1.3 Ground liquefaction
5.2 Indirect risk initiated by seismic motion
5.2.1 Fire and toxic or damaging effluent
5.2.2 Explosion
5.2.3 Flooding
5.2.4 Utilities
5.2.4.1 General
13 5.2.4.2 Electricity
5.2.4.3 Gas
5.2.4.4 Water
5.2.4.5 Sewerage
5.2.5 Access
5.2.6 Transport
14 5.2.7 Security systems
6 Seismic activity risk assessment
6.1 General
6.2 Ground motion
15 6.3 Ground stability
16 6.4 Evaluation by Probable Maximum Loss (PML)
6.4.1 General
17 6.4.2 Advantages and disadvantages
6.4.2.1 Advantages
6.4.2.2 Disadvantages
7 Seismic activity risk mitigation
7.1 Direct risk of seismic motion
7.1.1 General
7.1.2 Structural mitigation using isolation base techniques
7.1.2.1 General
18 7.1.2.2 Passive damper technologies
19 7.1.2.3 Base isolation technologies
20 7.1.3 Localized mitigation
7.1.3.1 Rack isolation
21 7.1.3.2 Pathways, pathway systems and cabling
7.1.4 Roofs and ceiling supports
7.1.4.1 Suspended equipment of mass 16 kg to 100 kg
7.1.4.2 Suspended ducts and cable management systems of mass 16kg to 100 kg
22 7.1.4.3 Lighting systems in suspended ceilings
7.2 Indirect risk initiated by seismic motion
7.2.1 Fire and toxic or damaging effluent
7.2.1.1 Fire
23 7.2.1.2 Toxic or damaging effluent
7.2.2 Explosion
7.2.3 Flooding
7.2.4 Utilities
7.2.4.1 General
7.2.4.2 Electricity
7.2.4.3 Gas
7.2.4.4 Water
7.2.4.5 Sewerage
24 7.2.5 Access
7.2.6 Transport
8 Disaster planning and recovery