BSI PD IEC TR 63396:2021
$142.49
Noise measurement method on power capacitors
Published By | Publication Date | Number of Pages |
BSI | 2021 | 26 |
The object of this Technical Report is to document a method for the sound pressure level measurement on power capacitor units, by which the sound power level of power capacitor units is determined.
This method is applicable to shunt capacitor units and AC filter capacitor units for AC power systems with a nominal voltage of 1 kV and above and a frequency of 50 Hz or 60 Hz.
This method also applies to the DC filter capacitor units.
Other measurements on power capacitor units can be implemented with reference to this method.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
4 | CONTENTS |
6 | FOREWORD |
8 | INTRODUCTION |
9 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Noise measurement 4.1 Power injection conditions for capacitors 4.1.1 Current injection conditions for shunt capacitor units |
13 | 4.1.2 Current injection conditions for AC filter capacitor units 4.1.3 Current and voltage injection conditions for DC filter capacitor units 4.2 Measuring environment 4.3 Characteristics for basic acoustic instruments 4.4 Arrangement of the power capacitors |
14 | 4.5 Arrangement of the microphone 4.6 Measurement on sound pressure levels 4.6.1 General 4.6.2 Calculation of average sound pressure level at measurement surface |
15 | Tables Table 1 – Test acceptance criteria |
16 | 5 Measurement of uncertainty |
17 | 6 Test report |
18 | Annex A (informative)Microphone arrangement on noise measurementsurface of power capacitors A.1 Measurement surface Figures Figure A.1 – Schematic diagram of installation of the test object |
19 | A.2 Measurement positions and orientation of microphone Figure A.2 – Microphone positions on the parallelepiped measurement surface Table A.1 – Coordinates of measurement positionson the parallelepiped measurement surface |
20 | Annex B (informative)Typical test circuit for power capacitor noise measurement B.1 Shunt and AC filter power capacitor noise test circuit B.2 DC filter power capacitor noise test circuit Figure B.1 – Schematic diagram of shunt and AC filter power capacitor noise test circuit Figure B.2 – Schematic diagram of DC filter power capacitor noise test circuit |
21 | Annex C (informative)Typical format of power capacitor noise test report C.1 Basic information in the typical test report C.2 Sound level meter parameters C.3 Test parameter configuration |
22 | C.4 Noise measurement data Table C.1 – Power supply loaded to the test object Table C.2 – Background A-weighted sound pressure levelof each measuring point in decibels Table C.3 – A-weighted sound pressure level of each measuring point in decibels |
23 | C.5 Meteorological conditions of the test environment C.6 Measuring personnel and time |
24 | Bibliography |