BSI PD ISO/TS 20684-10:2021
$167.15
Intelligent transport systems. Roadside modules SNMP data interface – Variable message signs
Published By | Publication Date | Number of Pages |
BSI | 2021 | 38 |
Variable message signs (VMSs) are installed in areas where traffic managers identify a frequent need to convey information to the travelling public, such as upstream from interchanges to alert the public to downstream congestion in time for them to alter their routes. This allows traffic managers to improve the efficiency, safety, and quality of traveller journeys.
In order to manage the operation of a VMS and the messages displayed, information exchange between the management systems and the VMS is needed.
This document identifies basic user needs for the management of light-emitting diode (LED) matrix VMSs and traces these needs to interoperable designs. This includes the ability to identify the device, its capabilities, and its status.
NOTE 1 This document is similar to portions of NTCIP 1203 v03, which defines how to manage VMSs using an older version of SNMP and is a normative reference in this document.
NOTE 2 ISO 20684‑1 provides additional details about how this series of standards relates to the overall ITS architecture.
PDF Catalog
PDF Pages | PDF Title |
---|---|
2 | undefined |
7 | Foreword |
8 | Introduction |
11 | 1 Scope 2 Normative references 3 Terms and definitions |
12 | 4 Symbols and abbreviated terms |
13 | 5 Conformance |
16 | 6 Physical architecture 7 User needs 7.1 Manage the control mode of the VMS |
17 | 7.2 Manage the sign display 7.3 Monitor the sign display doors 7.4 Monitor the sign display mains power 7.5 Monitor the sign display power supplies 8 Requirements 8.1 Message sign control mode 8.1.1 Message sign control mode definition 8.1.2 Message sign control mode data exchange requirements |
18 | 8.1.3 Message sign control mode capabilities 8.2 Message library 8.2.1 Message library definition 8.2.2 Message library data exchange requirements |
20 | 8.2.3 Message library capabilities |
22 | 8.3 Sign display 8.3.1 Sign display definition 8.3.2 Sign display data exchange requirements |
24 | 8.4 Sign display doors 8.4.1 Sign display doors definition 8.4.2 Sign display doors data exchange requirements 8.4.3 Sign display door capability requirements 8.4.4 Sign display door design constraints 8.5 Sign display mains power 8.5.1 Sign display mains power definition 8.5.2 Sign display mains power data exchange requirements 8.5.3 Sign display mains power capability requirements 8.5.4 Sign display mains power design constraints |
25 | 8.6 Sign display power supplies 8.6.1 Sign display power supplies definition 8.6.2 Sign display power supplies exchange requirements 8.6.3 Sign display power supplies capability requirements 8.6.4 Sign display power supplies design constraints 8.7 Sign display light sensors 8.7.1 Sign display light sensors definition 8.7.2 Sign display light sensors exchange requirements 8.7.3 Sign display light sensors capability requirements |
26 | 8.7.4 Sign display light sensors design constraints 8.8 Sign display pixels 8.8.1 Sign display pixels definition 8.8.2 Sign display pixels data exchange requirements 8.8.3 Sign display pixels capability |
27 | Annex A (normative) Management Information Base |
31 | Annex B (normative) Requirements Traceability Matrix |
36 | Annex C (informative) Relationship to NTCIP 1203 |
37 | Bibliography |