Shopping Cart

No products in the cart.

CA Building Code Volumes 1 2 2022 1stptg

$141.25

California Building Code, Title 24, Part 2 (Volumes 1 & 2) (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2022 1734
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies). This 2-volume set is a fully integrated code based on the 2021 International Building Code®. Effective Date: January 1, 2023.

PDF Catalog

PDF Pages PDF Title
1 2022 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2
2022 California Building Code, Volume 1
2 2022 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 TITLE PAGE
3 2022 Title 24, Part 2, Volume 1, CALIFORNIA BUILDING CODE, SUPPLEMENT July 1, 2024
7 2022 Title 24, Part 2, Vol. 1, California Building Code, ERRATA January 1, 2023
9 COPYRIGHT
Copyright
10 PREFACE
ACKNOWLEDGMENTS
11 CALIFORNIA CODE OF REGULATIONS, TITLE 24
13 California Matrix Adoption Tables Format of the California Matrix Adoption Tables
19 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
20 ARRANGEMENT AND FORMAT OF THE 2021 IBC
ARRANGEMENT AND FORMAT OF THE 2021 IBC
48 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION
49 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued
52 CHAPTER 1 SCOPE AND ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
55 SECTION 1.2 BUILDING STANDARDS COMMISSION
56 SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS
SECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
57 SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
58 SECTION 1.8.3 LOCAL ENFORCING AGENCY
59 SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
60 SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
61 SECTION 1.8.8 APPEALS BOARD
SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
71 SECTION 1.12 STATE LIBRARIAN
SECTION 1.13 DEPARTMENT OF WATER RESOURCES
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION
72 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION SECTION 101 SCOPE AND GENERAL REQUIREMENTS
DIVISION II SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 SCOPE AND GENERAL REQUIREMENTS
73 SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 CODE COMPLIANCE AGENCY
SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 CODE COMPLIANCE AGENCY
74 SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
75 SECTION 105 PERMITS
SECTION 105 PERMITS
77 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 106 FLOOR AND ROOF DESIGN LOADS
78 SECTION 107 CONSTRUCTION DOCUMENTS
79 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
80 SECTION 110 INSPECTIONS
SECTION 110 INSPECTIONS
81 SECTION 112 SERVICE UTILITIES
SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
82 SECTION 113 MEANS OF APPEALS
SECTION 115 STOP WORK ORDER
SECTION 114 VIOLATIONS
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
SECTION 113 MEANS OF APPEALS
SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
84 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
85 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
88 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
89 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
90 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
91 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
92 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
93 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
94 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
144 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – OCCUPANCY CLASSIFICATION AND USE
146 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
147 SECTION 304 BUSINESS GROUP B
148 SECTION 306 FACTORY GROUP F
SECTION 305 EDUCATIONAL GROUP E
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
149 SECTION 307 HIGH-HAZARD GROUP H
SECTION 307 HIGH-HAZARD GROUP H
153 SECTION 308 INSTITUTIONAL GROUP I
155 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
157 SECTION 311 STORAGE GROUP S
158 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM]
SECTION 314 ORGANIZED CAMPS GROUP C [SFM]
160 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
161 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE— continued
164 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
167 EQUATION 4-1
168 SECTION 403 HIGH-RISE BUILDINGS
171 SECTION 404 ATRIUMS
172 SECTION 405 UNDERGROUND BUILDINGS
SECTION 405 UNDERGROUND BUILDINGS
173 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
176 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
178 SECTION 407 GROUP I-2
183 SECTION 408 GROUP I-3
189 SECTION 409 MOTION PICTURE PROJECTION ROOMS
SECTION 409 MOTION PICTURE PROJECTION ROOMS
190 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
192 SECTION 411 SPECIAL AMUSEMENT AREAS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
SECTION 411 SPECIAL AMUSEMENT AREAS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
194 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
195 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
196 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
199 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
202 [F] TABLE 415.6.5 DETACHED BUILDING REQUIRED
204 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
209 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
210 SECTION 418 ORGANIC COATINGS
SECTION 419 ARTIFICIAL DECORATIVE VEGETATION
SECTION 417 DRYING ROOMS
SECTION 420 GROUPS R-1, R-2,
AND R-4
R-3,
212 SECTION 422 AMBULATORY CARE FACILITIES
SECTION 421 HYDROGEN FUEL GAS ROOMS
213 SECTION 423 STORM SHELTERS
214 SECTION 424 PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
SECTION 424 PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
215 SECTION 427 MEDICAL GAS SYSTEMS
SECTION 427 MEDICAL GAS SYSTEMS
216 SECTION 435 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM]
219 SECTION 436 GROUP I-4 [SFM]
SECTION 437 RESERVED
220 SECTION 438 RESERVED
SECTION 439 ROAD TUNNELS, BRIDGES AND OTHER LIMITED-ACCESS HIGHWAYS [SFM]
SECTION 440 HORSE RACING STABLES [SFM]
SECTION 441 PET KENNELS AND PET BOARDING FACILITIES [SFM]
SECTION 442 COMBUSTION ENGINES AND GAS TURBINES [SFM]
SECTION 443 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS [SFM]
SECTION 444 EXPLOSIVES [SFM]
221 SECTION 445 RESERVED
SECTION 446 WINERY CAVES [SFM]
222 SECTION 447 RESERVED
SECTION 448 RESERVED
SECTION 449 PUBLIC LIBRARIES [SL AND SFM]
SECTION 450 GROUP C [SFM]
224 SECTION 451 RESERVED
SECTION 452 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E CHILD CARE
228 TABLE 453.7.2.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
SECTION 454 RESERVED
SECTION 455 LARGE FAMILY DAY-CARE HOMES [SFM]
230 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
232 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
233 FIGURE 5-1
234 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
238 SECTION 506 BUILDING AREA
239 SECTION 507 UNLIMITED AREA BUILDINGS
242 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b, j
TABLE 506.3.3 FRONTAGE INCREASE FACTORa
243 TABLE 506.3.3.1 SECTION 507 BUILDINGSa
245 SECTION 508 MIXED USE AND OCCUPANCY
247 SECTION 509 INCIDENTAL USES
249 SECTION 510 SPECIAL PROVISIONS
252 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
254 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
256 EQUATION 6-1
258 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
260 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
262 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE-USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE-USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
263 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
265 SECTION 705 EXTERIOR WALLS
SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
268 EQUATION 7-2
FIGURE 705.7 EQUIVALENT OPENING FACTOR
269 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
270 SECTION 706 FIRE WALLS
SECTION 706 FIRE WALLS
271 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
273 SECTION 707 FIRE BARRIERS
275 SECTION 708 FIRE PARTITIONS
276 SECTION 709 SMOKE BARRIERS
277 SECTION 710 SMOKE PARTITIONS
278 SECTION 711 FLOOR AND ROOF ASSEMBLIES
SECTION 712 VERTICAL OPENINGS
280 SECTION 713 SHAFT ENCLOSURES
SECTION 713 SHAFT ENCLOSURES
281 SECTION 714 PENETRATIONS
SECTION 714 PENETRATIONS
284 SECTION 715 JOINTS AND VOIDS
SECTION 715 JOINTS AND VOIDS
285 SECTION 716 OPENING PROTECTIVES
SECTION 716 OPENING PROTECTIVES
286 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
287 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
293 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
TABLE 717.3.2.1 FIRE DAMPER RATING
299 SECTION 718 CONCEALED SPACES
SECTION 718 CONCEALED SPACES
300 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
301 SECTION 720 THERMALAND SOUND-INSULATING MATERIALS
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
302 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
303 SECTION 722 CALCULATED FIRE RESISTANCE
SECTION 722 CALCULATED FIRE RESISTANCE
304 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
305 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
306 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
307 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
308 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
309 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
310 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
311 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
312 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
313 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
314 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
315 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
316 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
317 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
318 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
319 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
320 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
321 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
322 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
323 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
324 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
325 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
326 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
327 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
328 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-3
EQUATION 7-4
329 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
330 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
331 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
EQUATION 7-5
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
332 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
333 FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
334 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
335 EQUATION 7-6
336 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
337 TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(3) VALUES OF Rn0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
338 TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-9
EQUATION 7-10
EQUATION 7-11
339 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
340 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(1)—continued W/D RATIOS FOR STEEL COLUMNS
341 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
342 TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
343 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
344 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
345 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
346 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
347 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
348 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1 (6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1 (6)(a)]
349 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
350 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa
351 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-13
EQUATION 7-14
352 EQUATION 7-15
EQUATION 7-16
353 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
354 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
355 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
356 TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
358 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
368 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
370 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
373 SECTION 804 INTERIOR FLOOR FINISH
374 SECTION 806 DECORATIVE MATERIALS AND TRIM
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
375 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
376 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS
377 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
380 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
381 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
382 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
383 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
388 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED PROTECTION SYSTEMS
392 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
395 SECTION 905 STANDPIPE SYSTEMS
SECTION 905 STANDPIPE SYSTEMS
398 SECTION 906 PORTABLE FIRE EXTINGUISHERS
SECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE
399 [F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
400 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
417 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 908 EMERGENCY ALARM SYSTEMS
418 SECTION 909 SMOKE CONTROL SYSTEMS
420 EQUATION 9-2
426 SECTION 910 SMOKE AND HEAT REMOVAL
SECTION 910 SMOKE AND HEAT REMOVAL
427 EQUATION 9-3
EQUATION 9-4
428 SECTION 911 FIRE COMMAND CENTER
SECTION 911 FIRE COMMAND CENTER
429 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 912 FIRE DEPARTMENT CONNECTIONS
430 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
431 SECTION 915 CARBON MONOXIDE DETECTION
SECTION 915 CARBON MONOXIDE DETECTION
433 SECTION 916 GAS DETECTION SYSTEMS
SECTION 916 GAS DETECTION SYSTEMS
434 SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER COMMUNICATION COVERAGE
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER COMMUNICATION COVERAGE
436 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
437 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
438 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
439 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
440 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
442 SECTION 1004 OCCUPANT LOAD
SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
443 SECTION 1005 MEANS OF EGRESS SIZING
SECTION 1005 MEANS OF EGRESS SIZING
444 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
447 TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 AND R-3 OCCUPANCIES
448 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
450 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
453 SECTION 1010 DOORS, GATES AND TURNSTILES
461 TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
463 SECTION 1011 STAIRWAYS
SECTION 1011 STAIRWAYS
467 SECTION 1012 RAMPS
SECTION 1012 RAMPS
468 SECTION 1013 EXIT SIGNS
470 SECTION 1014 HANDRAILS
SECTION 1014 HANDRAILS
471 SECTION 1015 GUARDS
SECTION 1015 GUARDS
473 SECTION 1016 EXIT ACCESS
474 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
475 SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
SECTION 1018 AISLES
476 SECTION 1020 CORRIDORS
478 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
480 SECTION 1024 EXIT PASSAGEWAYS
SECTION 1024 EXIT PASSAGEWAYS
481 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
483 SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
484 SECTION 1028 EXIT DISCHARGE
485 SECTION 1029 EGRESS COURTS
SECTION 1030 ASSEMBLY
487 TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
490 TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
493 SECTION 1031 EMERGENCY ESCAPE AND RESCUE
SECTION 1031 EMERGENCY ESCAPE AND RESCUE
496 CHAPTER 11
CHAPTER 11 RESERVED
498 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY
500 CHAPTER 11A HOUSING ACCESSIBILITY
DIVISION 1: APPLICATION, GENERAL PROVISIONS AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY
501 SECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS
502 SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS
503 DIVISION II: EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES
505 SECTION 1110A EXTERIOR ACCESSIBLE ROUTES
506 SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES
507 SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
508 SECTION 1115A EXTERIOR STAIRWAYS
509 SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES
512 SECTION 1120A RESERVED
SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
513 SECTION 1123A INTERIOR STAIRWAYS
514 SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
515 TABLE 1124A.3.2 ELEVATOR CAR DIMENSIONS
517 SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
SECTION 1126A DOORS, GATES AND WINDOWS
519 SECTION 1127A COMMON USE FACILITIES
528 DIVISION IV: DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS
530 SECTION 1133A KITCHENS
531 SECTION 1134A BATHING AND TOILET FACILITIES
537 SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS
538 SECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS
539 SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE
540 TABLE 1143A.5 VISUAL CHARACTER HEIGHT
541 TABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED
542 DIVISION VI: SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1—INDIVIDUAL BUILDING TEST
TEST NO. 2—SITE ANALYSIS TEST
543 TEST NO. 3—UNUSUAL CHARACTERISTICS TEST
544 DIVISION VII: FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL
545 FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION
546 FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS
547 FIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH
548 FIGURE 11A-1F CHANGE IN LEVEL
549 FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS
550 FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES
551 FIGURE 11A-1I FORWARD REACH
552 FIGURE 11A-1J SIDE REACH
553 FIGURE 11A-1K MINIMUM CLEARANCES FOR SEATING AND TABLE
554 FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE
555 FIGURE 11A-2A DOUBLE PARKING STALLS
FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS
556 FIGURE 11A-2C DIAGONAL PARKING STALLS
557 FIGURE 11A-3A CURB DETAILS
558 FIGURE 11A-3B CURB DETAIL
559 FIGURE 11A-3C CURB DETAIL
560 FIGURE 11A-3D CURB DETAIL
FIGURE 11A-3E CURB DETAIL
561 FIGURE 11A-3F CURB DETAIL – SIDEWALK LESS THAN 60″ WIDE
FIGURE 11A-3G CURB DETAIL
562 FIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL
563 FIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL
564 FIGURE 11A-3L CURB SECTIONS
565 FIGURE 11A-5A RAMPS AND SIDEWALKS
566 FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS
567 FIGURE 11A-6B HANDRAILS
568 FIGURE 11A-6C RAMP DIMENSIONS
569 FIGURE 11A-6D RAMP LANDING AND DOORWAY
570 FIGURE 11A-6E STAIR HANDRAILS
571 FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS
572 FIGURE 11A-7B ELEVATOR CONTROL PANEL
573 FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION
574 FIGURE 11A-8A MANEUVERING CLEARANCE AT SWINGING DOORS
575 FIGURE 11A-8B MANEUVERING CLEARANCE AT DOORWAYS, SLIDING DOORS AND FOLDING DOORS
576 FIGURE 11A-8C MANEUVERING CLEARANCES AT RECESSED DOORS
577 FIGURE 11A-8G VESTIBULE
578 FIGURE 11A-8H VESTIBULE
579 FIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR
580 FIGURE 11A-9A TOILET FACILITIES
581 FIGURE 11A-9B WATER CLOSETS
582 FIGURE 11A-9C GRAB BARS
583 FIGURE 11A-9D KNEE AND TOE SPACE
584 FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS
585 FIGURE 11A-9F GRAB BARS AT BATHTUBS
586 FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS
587 FIGURE 11A-9H STANDARD ROLL-IN SHOWER
588 FIGURE 1A-9I SHOWER SEATS AND GRAB BARS
589 FIGURE 11A-9J OPEN SHOWER
590 FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER
591 FIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET
592 FIGURE 11A-10A KITCHEN SPECIFICATIONS
593 FIGURE 11A-11A DRINKING FOUNTAINS
594 FIGURE 11A-11B TELEPHONES
595 FIGURE 11A-11C INTERNATIONAL TTY SYMBOL
FIGURE 11A-11D VOLUME CONTROL TELEPHONES
FIGURE 11A-11E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
596 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERC
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
598 1: APPLICATION AND ADMINISTRATION
CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS,PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
600 11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES
601 2: SCOPING REQUIREMENTS
DIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES
603 11B-203 GENERAL EXCEPTIONS
604 11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
FIGURE 11B-205.1 Ex. 9 ELECTRICAL RECEPTACLES AT CORNER WORK SURFACES
11B-206 ACCESSIBLE ROUTES
609 11B-207 ACCESSIBLE MEANS OF EGRESS
11B-208 PARKING SPACES
TABLE 11B-208.2 PARKING SPACES
616 11B-219 ASSISTIVE LISTENING SYSTEMS
11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
11B-221 ASSEMBLY AREAS
617 TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
618 11B-222 DRESSING, FITTING AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES
619 11B-224 TRANSIENT LODGING GUEST ROOMS, HOUSING AT A PLACE OF EDUCATION AND SOCIAL SERVICE CENTER ESTABLISHMENTS
622 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, FUEL DISPENSERS AND ELECTRIC VEHICLE CHARGING STATIONS
TABLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC USE AND COMMON USE
623 11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATOIN SYSTEMS
11B-231 JUDICIAL FACILITIES
11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES
627 11B-234 AMUSEMENT RIDES
11B-235 RECREATIONAL BOATING FACILITIES
628 TABLE 11B-235.2 BOAT SLIPS
11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
11B-240 PLAY AREAS
629 TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
11B-242 SWIMMING POOLS, WADING POOLS AND SPAS
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
632 3: BUILDING BLOCKS
DIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL
11B-304 TURNING SPACE
633 FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
634 FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.3 KNEE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE
635 11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS
636 FIGURE 11B-307.4 VERTICAL CLEARANCE
FIGURE 11B-307.4.1 GUY BRACES
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH
637 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
TABLE 11B-308.4 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-309 OPERABLE PARTS
638 4: ACCESSIBLE ROUTES
DIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
639 FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS AND GATES
640 FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
641 FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
642 FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
643 TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS and MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES and FOLDING DOORS
644 FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES
646 11B-405 RAMPS
647 FIGURE 11B-405.7 RAMP LANDINGS
FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
650 FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS
651 FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES
TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
652 FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
653 TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION
654 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
655 FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
656 FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL
11B-410 PLATFORM LIFTS
FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES
11B-411 DESTINATION-ORIENTED ELEVATORS
11B-411 DESTINATION-ORIENTED ELEVATORS
657 FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION
660 FIGURE 11B-411.2.3 FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES
662 5: GENERAL SITE AND BUILDING ELEMENTS
DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES
663 FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE
664 FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION
665 11B-503 PASSENGER DROP-OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE
666 11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS
667 FIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION
668 FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS
669 6: PLUMBING ELEMENTS AND FACILITIES
DIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS AND BOTTLE-FILLING STATIONS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS
670 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS
671 FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.1 DISPENSER OUTLET LOCATION
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.2 DISPOSAL UNIT LOCATION
680 FIGURE 11B-608.5.1 TRANSFER TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
681 11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
11B-610 SEATS
682 FIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS
683 FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS
684 7: COMMUNICATION ELEMENTS AND FEATURES
DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS
685 TABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
686 FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT
687 FIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY
688 FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.6.4 EDGES AND VERTICES ON GEOMETRIC SYMBOLS
689 TABLE 11B-703.8.4 LOW RESOLUTION VMS CHARACTER HEIGHT
TABLE 11B-703.8.5 PIXEL COUNT FOR LOW RESOLUTION VMS
11B-704 TELEPHONES
690 FIGURE 11B-703.8.5 LOW RESOLUTION VMS CHARACTERS
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
691 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES
692 FIGURE 11B-705.1.2.2.2 PARALLEL CURB RAMPS
693 FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
694 FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT
695 11B-708 TWO-WAY COMMUNICATION SYSTEMS
696 8: SPECIAL ROOMS, SPACES AND ELEMENTS
DIVISION 8: SPECIAL ROOMS, SPACES AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEAT
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
697 FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING AND LOCKER ROOMS
11B-804 KITCHENS, KITCHENETTES AND WET BARS
698 FIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS
699 11B-805 MEDICAL CARE AND LONG-TERM CARE FACILITIES
700 11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS
701 11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS
702 FIGURE 11B-809.8 Ex. 1(c) PLATFORM AT SECONDARY EXTERIOR DOOR
703 FIGURE 11B-809.8 Ex. 1(d) RAMP AT SECONDARY EXTERIOR DOOR
704 FIGURE 11B-809.9.2 CLEAR WIDTH AT KITCHENS
705 FIGURE 11B-809.10.5.2 REINFORCEMENT FOR GRAB BARS
706 FIGURE 11B-809.10.6.1 SHOWERS
FIGURE 11B-809.10.6.4 REINFORCEMENT FOR GRAB BARS
FIGURE 11B-809.10.7.1 FLOOR SPACE
707 FIGURE 11B-809.10.7.3 REINFORCEMENT FOR GRAB BARS
708 FIGURE 11B-809.12 ELECTRICAL RECEPTACLES AT CORNER WORKSURFACES
11B-810 TRANSPORTATOIN FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS
709 FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE
11B-812 ELECTRIC VEHICLE CHARGING STATIONS
711 FIGURE 11B-812.9 SURFACE MARKING
712 11B-813 ADULT CHANGING FACILITIES
FIGURE 11B-813.2.1.2 CLEARANCE AROUND ADULT CHANGING TABLE
713 9: BUILT-IN ELEMENTS
DIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS
FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
714 FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS
715 10: RECREATION FACILITIES
DIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
716 11B-1003 RECREATIONAL BOATING FACILITIES
717 FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
718 FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
11B-1004 EXERCISE MACHINES AND EQUIPMENT
719 11B-1005 FISHING PIERS AND PLATFORMS
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILITIES
720 11B-1007 MINIATURE GOLF FACILITIES
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
11B-1008 PLAY AREAS
721 FIGURE 11B-1008.3.1 TRANSFER PLATFORMS
722 FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS AND SPAS
FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
723 FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
724 FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT
FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
725 FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
726 FIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
728 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT
729 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT—continued
730 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
732 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
TABLE 1202.3.1 IECC VERSUS CALIFORNIA ENERGY CODE CLIMATE ZONE COMPARISON
733 SECTION 1203 TEMPERATURE CONTROL
SECTION 1203 TEMPERATURE CONTROL
734 SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
735 SECTION 1207 ENHANCED CLASSROOM ACOUSTICS
SECTION 1206 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
SECTION 1206 SOUND TRANSMISSION
SECTION 1207 ENHANCED CLASSROOM ACOUSTICS
SECTION 1208 INTERIOR SPACE DIMENSIONS
736 SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
737 SECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
799 SECTION 1226 [OSHPD 3] CLINICS
810 SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS
842 CHAPTER 13 ENERGY EFFICIENCY
CHAPTER 13 ENERGY EFFICIENCY
844 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS
846 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
847 SECTION 1403 MATERIALS
SECTION 1403 MATERIALS
848 SECTION 1404 INSTALLATION OF WALL COVERINGS
854 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
855 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
856 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
857 SECTION 1409 PLASTIC COMPOSITE DECKING
SECTION 1409 PLASTIC COMPOSITE DECKING
SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER
858 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
860 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1503 WEATHER PROTECTION
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
861 SECTION 1504 PERFORMANCE REQUIREMENTS
SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.2 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161OR D7158
862 SECTION 1505 FIRE CLASSIFICATION
864 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.1.1(1) UNDERLAYMENT TYPES
865 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
866 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
867 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
869 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa
870 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
871 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
872 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
873 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
874 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.12.2 SINGLE-PLY ROOFING MATERIAL STANDARDS
TABLE 1507.13.3 PROTECTIVE COATING MATERIAL STANDARDS
875 SECTION 1508 ROOF INSULATION
SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
876 SECTION 1509 ROOF COATINGS
SECTION 1510 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1511 ROOFTOP STRUCTURES
SECTION 1509 ROOF COATINGS
TABLE 1509.2 ROOF COATING MATERIAL STANDARDS
SECTION 1510 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1511 ROOFTOP STRUCTURES
878 SECTION 1512 REROOFING
SECTION 1512 REROOFING
879 SECTION 1513 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS
882 INDEX A
ACCESS OPENINGS
ACCESSIBILITY
INDEX
883 ACCESSORY OCCUPANCIES
ADDITION.
ADDRESS IDENTIFICATION.
ADJUSTED CONSTRUCTION COSTS
ADMINISTRATION
ADOBE CONSTRUCTION
AEROSOL PRODUCTS
AGGREGATE
AGRICULTURAL BUILDINGS (see GROUP U).
AIR CONDITIONING (see MECHANICAL) AIRCRAFT HANGARS.
AIRCRAFT MANUFACTURING FACILITIES
AIRCRAFT-RELATED OCCUPANCIES
ACCESSIBLE MEANS OF EGRESS.
884 ALTERNATIVE MATERIALS, DESIGN AND METHODS
ALUMINUM
AIR-INFLATED OR AIR-SUPPORTED STRUCTURES
AMBULATORY CARE FACILITIES
AISLE
AMUSEMENT AREA, SPECIAL
ALARM SYSTEMS, EMERGENCY
AMUSEMENT PARK STRUCTURES
ALARMS, FIRE (see FIRE ALARM AND SMOKE DETECTION SYSTEMS) ALARMS, VISIBLE
ANCHOR BUILDING (see COVERED MALL AND OPEN MALL BUILDING)
ANCHORAGE
ALARMS, VOICE
ALLOWABLE STRESS DESIGN
APARTMENT HOUSES
APPEALS
ALTERATIONS
APPROVED AGENCY.
ALTERNATING TREAD DEVICES.
885 ARCHITECT (see definitions for REGISTERED DESIGN PROFESSIONAL and REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE) ARCHITEC
AREA, BUILDING.
AREA FOR ASSISTED RESCUE, EXTERIOR (see EXTERIOR AREA FOR ASSISTED RESCUE) AREA OF REFUGE (see also ACCESSIBLE MEANS OF EGRESS).
ASSEMBLY OCCUPANCY (GROUP A)
ASSISTED LIVING (see GROUP I-1 and GROUP R-4)
ATMOSPHERIC ICE LOADS
886 ATRIUM.
BARBECUES
BARRIERS
BASEMENT (see UNDERGOUND BUILDINGS)
ATTIC
AUDITORIUM (see ASSEMBLY OCCUPANCY)
BASEMENT WALLS
BATH AND BATHING ROOMS (see TOILETS AND TOILET ROOMS)
AUTOMOBILE PARKING GARAGE (see GARAGE, AUTOMOBILE PARKING) AWNINGS
BAY AND ORIEL WINDOWS
BLEACHERS.
BLOCK (see CONCRETE BLOCK AND GLASS UNIT MASONRY) BOARD OF APPEALS
924 HISTORY NOTE APPENDIX
926 CODE RESOURCES FROM ICC
927 ICC DIGITAL CODES PREMIUM
928 2022 California Building Code, Volume 2
2022 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 2 OF 2
929 2022 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 2 OF 2 TITLE PAGE
930 2022 Title 24, Part 2, Volume 2, CALIFORNIA BUILDING CODE, SUPPLEMENT July 1, 2024
932 2022 Title 24, Part 2, Vol. 2, California Building Code, ERRATA January 1, 2023
934 Copyright
COPYRIGHT
935 PREFACE
ACKNOWLEDGMENTS
936 CALIFORNIA CODE OF REGULATIONS, TITLE 24
944 EFFECTIVE USE OF INTERNATIONAL BUILDING CODE
945 ARRANGEMENT AND FORMAT OF THE 2021 IBC
ARRANGEMENT AND FORMAT OF THE 2021 IBC
973 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 16 – STRUCTURAL DESIGN
975 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
976 SECTION 1603 CONSTRUCTION DOCUMENTS
SECTION 1603 CONSTRUCTION DOCUMENTS
977 SECTION 1604 GENERAL DESIGN REQUIREMENTS
SECTION 1604 GENERAL DESIGN REQUIREMENTS
978 TABLE 1604.3 DEFLECTION LIMITS
979 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
980 SECTION 1605 LOAD COMBINATIONS
SECTION 1605 LOAD COMBINATIONS
981 SECTION 1607 LIVE LOADS
SECTION 1606 DEAD LOADS
983 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
984 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
986 EQUATION 16-7
TABLE 1607.12.1 LIVE LOAD ELEMENT FACTOR
987 EQUATION 16-8
EQUATION 16-9
988 EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
990 SECTION 1608 SNOW LOADS
SECTION 1609 WIND LOADS
SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
991 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
992 FIGURE 1608.2(1) GROUND SNOW LOADS, pg, FOR THE UNITED STATES
993 FIGURE 1608.2(2) GROUND SNOW LOADS, pg, FOR THE UNITED STATES
994 EQUATION 16-17
995 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
996 FIGURE 1609.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
997 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
998 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
999 SECTION 1610 SOIL LOADS AND HYDROSTATIC PRESSURE
EQUATION 16-18
TABLE 1609.3.1 WIND SPEED CONVERSIONS
SECTION 1610 SOIL LOADS AND HYDROSTATIC PRESSURE
1000 SECTION 1611 RAIN LOADS
TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
EQUATION 16-19
1001 FIGURE 1611.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
1002 FIGURE 1611.1(2) 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
1003 FIGURE 1611.1(3) 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
1004 FIGURE 1611.1(4) 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
1005 FIGURE 1611.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
1006 SECTION 1612 FLOOD LOADS
SECTION 1612 FLOOD LOADS
1007 SECTION 1613 EARTHQUAKE LOADS
SECTION 1613 EARTHQUAKE LOADS
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
1008 EQUATION 16-23
TABLE 1613.2.3(1) [OSHPD 1R, 2 & 5] VALUES OF SITE COEFFICIENT
TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT
1009 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
1010 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1011 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1012 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING
1013 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE COTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1014 FIGURE 1613.2.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1015 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1016 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1017 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1018 FIGURE 1613.2.1(9) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1019 FIGURE 1613.2.1(10) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1020 SECTION 1616 STRUCTURAL INTEGRITY
SECTION 1616 STRUCTURAL INTEGRITY
FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
1021 EQUATION 16-24
EQUATION 16-25
SECTION 1617 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1029 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 16A – STRUCTURAL DESIGN
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 16A – STRUCTURAL DESIGN
1031 CHAPTER 16A STRUCTURAL DESIGN
SECTION 1601A GENERAL
SECTION 1603A CONSTRUCTION DOCUMENTS
SECTION 1602A NOTATIONS
CHAPTER 16A STRUCTURAL DESIGN
SECTION 1601A GENERAL
SECTION 1602A NOTATIONS
SECTION 1603A CONSTRUCTION DOCUMENTS
1033 SECTION 1604A GENERAL DESIGN REQUIREMENTS
SECTION 1604A GENERAL DESIGN REQUIREMENTS
1034 TABLE 1604A.3 DEFLECTION LIMITS
1035 TABLE 1604A.4 MAXIMUM HORIZONTAL DIAPHRAGM SPAN AND SPAN-DEPTH RATIOS
1036 TABLE 1604A.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
1037 SECTION 1605A LOAD COMBINATIONS
SECTION 1605A LOAD COMBINATIONS
1038 SECTION 1607A LIVE LOADS
SECTION 1606A DEAD LOADS
EQUATION 16A-1
EQUATION 16A-2
EQUATION 16A-3
EQUATION 16A-4
EQUATION 16A-5
EQUATION 16A-6
EQUATION 3-5A
SECTION 1606A DEAD LOADS
SECTION 1607A LIVE LOADS
1039 TABLE 1607A.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1040 TABLE 1607A.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1041 TABLE 1607A.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1043 EQUATION 16A-7
1044 TABLE 1607A.12.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16A-8
EQUATION 16A-9
1045 EQUATION 16A-10
EQUATION 16A-11
EQUATION 16A-12
EQUATION 16A-13
EQUATION 16A-14
EQUATION 16A-15
EQUATION 16A-16
1047 SECTION 1608A SNOW LOADS
SECTION 1608A SNOW LOADS
1048 FIGURE 1608A.2(1) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
1049 FIGURE 1608A.2(2) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
1050 SECTION 1609A WIND LOADS
SECTION 1609A WIND LOADS
TABLE 1609A.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
1051 EQUATION 16A-17
1053 FIGURE 1609A.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
1054 FIGURE 1609A.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
1055 FIGURE 1609A.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
1056 FIGURE 1609A.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
1057 SECTION 1610A SOIL LOADS AND HYDROSTATIC PRESSURE
TABLE 1609A.3.1 WIND SPEED CONVERSIONS
EQUATION 16A-18
SECTION 1610A SOIL LOADS AND HYDROSTATIC PRESSURE
1058 SECTION 1611A RAIN LOADS
TABLE 1610A.1 LATERAL SOIL LOAD
SECTION 1611A RAIN LOADS
EQUATION 16A-19
1059 SECTION 1612A FLOOD LOADS
SECTION 1612A FLOOD LOADS
1060 FIGURE 1611A.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
1061 FIGURE 1611A.1(2) 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
1062 FIGURE 1611A.1(3) 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
1063 FIGURE 1611A.1(4) 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
1064 FIGURE 1611A.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
1065 SECTION 1613A EARTHQUAKE LOADS
SECTION 1614A ATMOSPHERIC ICE LOADS
SECTION 1613A EARTHQUAKE LOADS
EQUATION 16A-20
EQUATION 16A-21
EQUATION 16A-22
EQUATION 16A-23
SECTION 1614A ATMOSPHERIC ICE LOADS
1066 SECTION 1616A STRUCTURAL INTEGRITY
SECTION 1615A TSUNAMI LOADS
TABLE 1613A.2.3(1) VALUES OF SITE COEFFICIENT Faa
TABLE 1613A.2.3(2) VALUES OF SITE COEFFICIENT FVa
SECTION 1615A TSUNAMI LOADS
SECTION 1616A STRUCTURAL INTEGRITY
1067 FIGURE 1616A.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
1068 SECTION
MODIFICATIONS TO ASCE 7
EQUATION 16A-24
EQUATION 16A-25
SECTION 1617A MODIFICATIONS TO ASCE 7
1079 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17 – SPECIAL INSPECTIONS AND TESTS
1080 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17 – SPECIAL INSPECTIONS AND TESTS—continued
1081 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1703 APPROVALS
SECTION 1702 NEW MATERIALS
CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
1082 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
1084 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
1085 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
1091 TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
1092 TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
1094 TABLE 1705.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
1097 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
SECTION 1709 PRECONSTRUCTION LOAD TESTS
SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
SECTION 1709 PRECONSTRUCTION LOAD TESTS
1101 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17A – SPECIAL INSPECTIONS AND TESTS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17A – SPECIAL INSPECTIONS AND TESTS
1103 CHAPTER 17A SPECIAL INSPECTIONS AND TESTS
SECTION 1701A GENERAL
SECTION 1702A NEW MATERIALS
SECTION 1703A APPROVALS
1104 SECTION 1704A SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
1106 SECTION 1705A REQUIRED SPECIAL INSPECTIONS AND TESTS
1108 TABLE 1705A.2.1 REQUIRED SPECIAL INSPECTIONS AND TESTS OF STEEL CONSTRUCTION
1109 TABLE 1705A.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
1110 TABLE 1705A.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
1112 TABLE 1705A.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
1113 TABLE 1705A.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
1114 TABLE 1705A.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705A.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
1116 TABLE 1705A.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
1119 SECTION 1706A DESIGN STRENGTHS OF MATERIALS
SECTION 1707A ALTERNATIVE TEST PROCEDURE
SECTION 1706A DESIGN STRENGTHS OF MATERIALS
SECTION 1707A ALTERNATIVE TEST PROCEDURE
1120 SECTION 1708A IN-SITU LOAD TESTS
SECTION 1709A PRECONSTRUCTION LOAD TESTS
SECTION 1708A IN-SITU LOAD TESTS
SECTION 1709A PRECONSTRUCTION LOAD TESTS
1123 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18 – SOILS AND FOUNDATIONS
1124 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18 – SOILS AND FOUNDATIONS—continued
1125 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
SECTION 1802 DESIGN BASIS
CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
1129 SECTION 1804 EXCAVATION, GRADING AND FILL
SECTION 1804 EXCAVATION, GRADING AND FILL
1130 SECTION 1805 DAMPPROOFING AND WATERPROOFING
SECTION 1805 DAMPPROOFING AND WATERPROOFING
1131 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
1132 SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
1133 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
1134 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
1135 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHES
1136 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES
1137 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHES
1138 SECTION 1808 FOUNDATIONS
EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
1139 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
1140 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′c OF CONCRETE OR GROUT
1141 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
1142 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
1143 SECTION 1810 DEEP FOUNDATIONS
1146 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
1159 SECTION 1813 VIBRO STONE COLUMNS FOR GROUND IMPROVEMENT [OSHPD 1R, 2 & 5]
1161 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18A – SOILS AND FOUNDATIONS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18A – SOILS AND FOUNDATIONS
1163 CHAPTER 18A SOILS AND FOUNDATIONS
SECTION 1801A GENERAL
SECTION 1803A GEOTECHNICAL INVESTIGATIONS
SECTION 1802A DESIGN BASIS
CHAPTER 18A SOILS AND FOUNDATIONS
SECTION 1801A GENERAL
SECTION 1802A DESIGN BASIS
SECTION 1803A GEOTECHNICAL INVESTIGATIONS
1166 SECTION 1804A EXCAVATION, GRADING AND FILL
SECTION 1804A EXCAVATION, GRADING AND FILL
1167 SECTION 1805A DAMPPROOFING AND WATERPROOFING
SECTION 1805A DAMPPROOFING AND WATERPROOFING
1169 SECTION 1806A PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
SECTION 1807A FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
SECTION 1806A PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
TABLE 1806A.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807A FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
1170 EQUATION 18A-1
1171 SECTION 1808A FOUNDATIONS
EQUATION 18A-2
EQUATION 18A-3
SECTION 1808A FOUNDATIONS
1172 FIGURE 1808A.7.1 FOUNDATION CLEARANCES FROM SLOPES
1173 TABLE 1808A.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′c OF CONCRETE OR GROUT
TABLE 1808A.8.2 MINIMUM CONCRETE COVER
1174 SECTION 1809A SHALLOW FOUNDATIONS
SECTION 1809A SHALLOW FOUNDATIONS
1175 SECTION 1810A DEEP FOUNDATIONS
SECTION 1810A DEEP FOUNDATIONS
1177 TABLE 1810A.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
1179 EQUATION 18A-4
1181 EQUATION 18A-5
1186 SECTION 1811A PRESTRESSED ROCK AND SOIL FOUNDATION ANCHORS
SECTION 1812A EARTH RETAINING SHORING
1191 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 19 – CONCRETE
1193 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
1195 SECTION 1902 COORDINATION OF TERMINOLOGY
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
1196 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
1199 SECTION 1908 SHOTCRETE
SECTION 1906 FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907 MINIMUM SLAB PROVISIONS
1202 TABLE 21.2.2 STRENGTH REDUCTION FACTOR φ FOR MOMENT, AXIAL FORCE, OR COMBINED MOMENT AND AXIAL FORCE
1207 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 19A – CONCRETE
1209 CHAPTER 19A CONCRETE
SECTION 1901A GENERAL
1210 SECTION 1902A COORDINATION OF TERMINOLOGY
SECTION 1903A SPECIFICATIONS FOR TESTS AND MATERIALS
1211 SECTION 1904A DURABILITY REQUIREMENTS
SECTION 1905A MODIFICATIONS TO ACI 318
1213 TABLE 21.2.2 STRENGTH REDUCTION FACTOR φ FOR MOMENT, AXIAL FORCE, OR COMBINED MOMENT AND AXIAL FORCE
1214 SECTION 1908A SHOTCRETE
SECTION 1906A FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907A MINIMUM SLAB PROVISIONS
SECTION 1906A FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907A MINIMUM SLAB PROVISIONS
SECTION 1908A SHOTCRETE
SECTION 1909A RESERVED
SECTION 1910A CONCRETE, REINFORCEMENT AND ANCHOR TESTING
1216 SECTION 1911A EXISTING CONCRETE STRUCTURES
1219 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 20 – ALUMINUM
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 20 – ALUMINUM
1221 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
SECTION 2003 TESTING AND INSPECTION
1223 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 21 – MASONRY
1225 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
1226 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
1227 SECTION 2104 CONSTRUCTION
1228 SECTION 2105 QUALITY ASSURANCE
1229 SECTION 2106 SEISMIC DESIGN
1230 SECTION 2107 ALLOWABLE STRESS DESIGN
1231 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
1233 SECTION 2110 GLASS UNIT MASONRY
SECTION 2110 GLASS UNIT MASONRY
1234 SECTION 2111 MASONRY FIREPLACES
SECTION 2111 MASONRY FIREPLACES
1235 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
1236 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
1239 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
1240 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
1241 SECTION 2114 DRY-STACK MASONRY
1244 TABLE 8.3.4.4 MINIMUM THICKNESS OF MASONRY WALLS1, 2
1245 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 21A – MASONRY
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 21A – MASONRY
1247 CHAPTER 21A MASONRY
SECTION 2101A GENERAL
SECTION 2102A NOTATIONS
SECTION 2103A MASONRY CONSTRUCTION MATERIALS
1248 SECTION 2104A CONSTRUCTION
1251 SECTION 2105A QUALITY ASSURANCE
1252 SECTION 2106A SEISMIC DESIGN
1253 SECTION 2107A ALLOWABLE STRESS DESIGN
1254 SECTION 2108A STRENGTH DESIGN OF MASONRY
SECTION 2111A MASONRY FIREPLACES
SECTION 2109A EMPIRICAL DESIGN OF ADOBE MASONRY
SECTION 2110A GLASS UNIT MASONRY
1256 FIGURE 2111A.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
1257 SECTION 2112A MASONRY HEATERS
SECTION 2113A MASONRY CHIMNEYS
SECTION 2112A MASONRY HEATERS
SECTION 2113A MASONRY CHIMNEYS
1259 FIGURE 2113A.16 FLUE SIZES FOR MASONRY CHIMNEYS
1261 SECTION 2114A DRY-STACK MASONRY
TABLE 2113A.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113A.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113A.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114A DRY-STACK MASONRY
1262 TABLE 2114A.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
1263 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 22 – STEEL
1265 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
1266 SECTION 2205 STRUCTURAL STEEL
SECTION 2205 STRUCTURAL STEEL
1268 SECTION 2207 STEEL JOISTS
SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
1269 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
1270 SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
1271 SECTION 2212 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1272 SECTION 2213 TESTING AND FIELD VERIFICATION [OSHPD 1R, 2 & 5]
1273 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 22A – STEEL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 22A – STEEL
1275 CHAPTER 22A STEEL
SECTION 2203A PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2201A GENERAL
SECTION 2204A CONNECTIONS
SECTION 2202A IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
CHAPTER 22A STEEL
SECTION 2201A GENERAL
SECTION 2202A IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203A PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204A CONNECTIONS
1276 SECTION 2205A STRUCTURAL STEEL
SECTION 2205A STRUCTURAL STEEL
1278 SECTION 2206A COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207A STEEL JOISTS
SECTION 2206A COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207A STEEL JOISTS
1279 SECTION 2208A STEEL CABLE STRUCTURES
SECTION 2208A STEEL CABLE STRUCTURES
1280 SECTION 2209A STEEL STORAGE RACKS
SECTION 2211A COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
SECTION 2210A COLD-FORMED STEEL
SECTION 2209A STEEL STORAGE RACKS
SECTION 2210A COLD-FORMED STEEL
SECTION 2211A COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
1281 SECTION 2212A [DSA-SS] LIGHT MODULAR STEEL MOMENT FRAMES FOR PUBLIC ELEMENTARY AND SECONDARY SCHOOLS, AND COMMUNITY COLLEGES
EQUATION 22A-1
1282 SECTION 2213A TESTING AND FIELD VERIFICATION
1283 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 23 – WOOD
1285 CHAPTER 23 WOOD
SECTION 2301 GENERAL
1286 SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
1290 FIGURE 2303.4.1.2(1) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING ONE ROW OF PITMR
1291 FIGURE 2303.4.1.2(2) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF ONE ROW OF PITMR
1292 FIGURE 2303.4.1.2(3) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING TWO ROWS OF PITMR
1293 FIGURE 2303.4.1.2(4) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF TWO ROWS OF PITMR
1294 FIGURE 2303.4.1.2(5) PITMR AND PITMDB FOR FLAT PORTION OF TOP CHORD IN A PIGGYBACK ASSEMBLY
1295 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
1296 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa
1297 TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
1298 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood structural panels are five-ply, five-layer unless otherwise noted)a
1301 TABLE 2304.10.2 FASTENING SCHEDULE
1302 TABLE 2304.10.2—continued FASTENING SCHEDULE
1303 TABLE 2304.10.2—continued FASTENING SCHEDULE
1304 TABLE 2304.10.2—continued FASTENING SCHEDULE
1305 TABLE 2304.10.2—continued FASTENING SCHEDULE
1306 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
1309 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c
EQUATION 23-2
1310 SECTION 2306 ALLOWABLE STRESS DESIGN
TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
1311 TABLE 2306.1 STANDARDS FOR DESIGN AND CONSTRUCTION OF WOOD ELEMENTS IN STRUCTURES USING ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
1312 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
FIGURE 2306.2(1) CASES 1 THROUGH 6 FOR USE WITH TABLE 2306.2(1)
1313 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb
1314 FIGURE 2306.2(2) FASTENER SPACING DIAGRAMS FOR USE WITH TABLE 2306.2(2)
1315 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
1316 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
1317 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
1319 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
1320 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS
1321 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS
1322 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1323 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1324 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1325 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES
1326 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
1327 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
1328 TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
1329 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
1330 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
1331 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
1332 TABLE 2308.6.1 WALL BRACING REQUIREMENTSa
1333 TABLE 2308.6.3(1) BRACING METHODS
1334 TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING
1335 TABLE 2308.6.3(5) HARDBOARD SIDING
1336 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
1337 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
1338 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
1340 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
1341 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
1343 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
1344 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
1345 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
1346 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
1347 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES
1348 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES
1349 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
1350 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES
1351 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
1352 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES
1353 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
1354 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES
1355 TABLE 2308.7.2(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
1356 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES
1357 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
1358 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES
1359 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES
TABLE 2308.7.2(7) RAFTER SPAN ADJUSTMENT FACTOR
1360 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSi
1361 TABLE 2308.7.3.1(1) HEEL JOINT CONNECTION ADJUSTMENT FACTORS
TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1362 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1363 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 24 – GLASS AND GLAZING
1365 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
1366 SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
TABLE 2403.2.1 MINIMUM GLAZING REQUIREMENTS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
1367 EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
1368 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
1369 SECTION 2406 SAFETY GLAZING
EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
1370 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
1371 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2407 GLASS IN HANDRAILS AND GUARDS
1372 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
SECTION 2410 [DSA-SS, DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] STRUCTURAL SEALANT GLAZING (SSG)
1374 SECTION 2411 [OSHPD 1, 1R, 2, 4 & 5] THERMAL BARRIERS IN ALUMINUM MULLION SYSTEMS
1377 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 25 – GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 25 – GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
1379 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
1380 SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
1381 SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
1382 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
1383 SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
1384 SECTION 2511 INTERIOR PLASTER
SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
1385 SECTION 2512 EXTERIOR PLASTER
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
1386 SECTION 2514 REINFORCED GYPSUM CONCRETE
SECTION 2514 REINFORCED GYPSUM CONCRETE
1387 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 26 – PLASTIC
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 26 – PLASTIC
1389 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
1393 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
1394 [BS]TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
1395 SECTION 2604 INTERIOR FINISH AND TRIM
[BS]TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
1396 [BS]TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
[BS]TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
1397 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
1398 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
1399 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
1400 SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
1401 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2613 FIBER-REINFORCED POLYMER
SECTION 2612 PLASTIC COMPOSITES
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
1402 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
1403 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 27 – ELECTRICAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 27 – ELECTRICAL
1405 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
1407 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 28 – MECHANICAL SYSTEMS
1409 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
1411 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
1412 [P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1413 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1414 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1416 [P] SECTION 2903 INSTALLATION OF FIXTURES
[P] SECTION 2903 INSTALLATION OF FIXTURES
1417 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 30 – ELEVATORS AND CONVEYING SYSTEMS
1419 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
1421 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3003 EMERGENCY OPERATIONS
1422 SECTION 3005 MACHINE ROOMS
SECTION 3004 CONVEYING SYSTEMS
SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
1423 SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
1424 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
1425 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
1427 SECTION 3009 SPECIAL REQUIREMENTS FOR ELEVATORS IN HOSPITALS
1429 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31 – SPECIAL CONSTRUCTION
1431 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
1432 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3103 TEMPORARY STRUCTURES
1433 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
1434 SECTION 3106 MARQUEES
SECTION 3105 AWNINGS AND CANOPIES
SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
1435 SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
1437 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
1438 SECTION 3113 RELOCATABLE BUILDINGS
SECTION 3112 GREENHOUSES
SECTION 3112 GREENHOUSES
SECTION 3113 RELOCATABLE BUILDINGS
1439 SECTION 3115 INTERMODAL SHIPPING CONTAINERS
SECTION 3114 PUBLIC USE RESTROOM BUILDINGS IN FLOOD HAZARD AREAS
SECTION 3114 PUBLIC USE RESTROOM BUILDINGS IN FLOOD HAZARD AREAS
SECTION 3115 INTERMODAL SHIPPING CONTAINERS
1442 TABLE 3115.8.5.3 ALLOWABLE SHEAR VALUES FOR INTERMODAL SHIPPING CONTAINER CORRUGATED STEEL WALLS FOR WIND OR SEISMIC LOADING
1443 FIGURE 3115.8.5.3(1) BRACING UNIT DISTRIBUTION—MAXIMUM LINEAR LENGTH
FIGURE 3115.8.5.3(2) BRACING UNIT DISTRIBUTION—MINIMUM LINEAR LENGTH
1444 FIGURE 3115.8.5.3(3) BRACING UNIT DISTRIBUTION—BOUNDARY ELEMENTS
FIGURE 3115.8.5.3(4) BRACING UNIT DISTRIBUTION—PENETRATION LIMITATIONS
1445 CHAPTER 31A SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING MAINTENANCE
1447 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31B – PUBLIC POOLS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31B – PUBLIC POOLS
1449 CHAPTER 31B [DPH] PUBLIC POOLS
DIVISION I-GENERAL
SECTION 3101B SCOPE
SECTION 3102B DEFINITIONS
1450 PLAN REVIEW, PERMITS, CONSTRUCTION AND FIELD INSPECTIONS
SECTION 3103B PLAN REVIEW
1451 SECTION 3104B CONSTRUCTION
SECTION 3105B PLAN COMPLIANCE INSPECTIONS
POOL STRUCTURE
SECTION 3106B SPECIAL REQUIREMENTS FOR SPRAY GROUNDS
1452 SECTION 3107 BALTERNATIVE EQUIPMENT, MATERIALS AND METHODS OF CONSTRUCTION
SECTION 3108B POOL CONSTRUCTION
SECTION 3109B POOL GEOMETRY
SECTION 3110B PERMANENT MARKINGS
1453 SECTION 3111B STEPS, RECESSED STEPS, LADDERS AND STAIRS
1454 SECTION 3112B HANDHOLDS
SECTION 3113B DIVING BOARDS AND PLATFORMS
SECTION 3114B POOL DECKS
SECTION 3115B POOL LIGHTING
1455 ANCILLARY FACILITIES
SECTION 3116B DRESSING, SHOWER AND TOILET FACILITIES
SECTION 3117B DRINKING FOUNTAINS
SECTION 3118B HOSE BIBBS
SECTION 3119B POOL ENCLOSURE
1456 SECTION 3120B REQUIRED SIGNS
1457 SECTION 3121B INDOOR POOL VENTILATION
SECTION 3122B POOL EQUIPMENT ENCLOSURE
SECTION 3123B GENERAL REQUIREMENTS
SECTION 3124B TURNOVER TIME
1458 SECTION 3125B RECIRCULATION PIPING SYSTEM AND COMPONENTS
SECTION 3126B RECIRCULATION PUMP CAPACITY
SECTION 3127B WATER SUPPLY INLETS
SECTION 3128B FILTERS (ALL TYPES)
SECTION 3129B RAPID SAND PRESSURE FILTERS
SECTION 3130B DIATOMACEOUS EARTH FILTERS
1459 SECTION 3131B HIGH-RATE SAND FILTERS
SECTION 3132B CARTRIDGE FILTERS
SECTION 3133B CHEMICAL FEEDERS
SECTION 3134B DISINFECTANT FEEDERS
1460 FIGURE 31B-1 DEPTHS AND CLEARANCES FOR POOLS WITH DIVING BOARDS GREATER THAN 30 INCHES (762 mm) ABOVE THE WATER LINE
TABLE 31B-1
1461 FIGURE 31B-2 DEPTHS AND CLEARANCES FOR POOLS WITH DIVING BOARDS 30 INCHES (762 MM) OR LESS ABOVE THE WATER LINE
TABLE 31B-2
1462 FIGURE 31B-3 DEPTHS AND CLEARANCES FOR POOLS WITHOUT DIVING BOARDS
TABLE 31B-3A POOLS WITH MAXIMUM WATER DEPTH ≤ 6’0″
TABLE 31B-3B POOLS WITH MAXIMUM WATER DEPTH > 6’0″
1463 SECTION 3135B GAS CHLORINATION EQUIPMENT ROOM
SECTION 3136B POOL SKIMMING SYSTEMS
1464 SECTION 3137B POOL FITTINGS
SECTION 3138B SPA POOL SPECIAL REQUIREMENTS
SECTION 3139B SOLAR HEATING INSTALLATIONS
SECTION 3140B CLEANING SYSTEMS
1465 SECTION 3141B WASTEWATER DISPOSAL
SECTION 3142B RESERVED
SECTION 3143B RESERVED
SECTION 3145B RESERVED
SECTION 3146B RESERVED
SECTION 3147B RESERVED
SECTION 3148B RESERVED
SECTION 3149B RESERVED
SECTION 3150B RESERVED
SECTION 3151B RESERVED
SECTION 3152B RESERVED
SECTION 3153B RESERVED
SECTION 3154B RESERVED
SECTION 3155B RESERVED
SECTION 3156B RESERVED
SECTION 3157B RESERVED
SECTION 3158B RESERVED
SECTION 3159B RESERVED
DIVISION II PUBLIC SWIMMING POOLS
SECTION 3160B GROUND FAULT CIRCUIT INTERRUPTERS
1466 SECTION 3161B WADING POOLS
SECTION 3162B ANTI-ENTRAPMENT DEVICES AND SYSTEMS
1469 FIGURE 31B-4 PERPENDICULAR FENCING DIMENSIONS ON SLOPING GROUND
FIGURE 31B-5 EFFECTIVE FENCING HEIGHT
1470 FIGURE 31B-6 DEPTHS AND DIMENSIONS FOR SPA POOLS
1471 TABLE 31B-6
FIGURE 31B-7 STAIR AND HANDRAIL DIMENSIONS
1472 FIGURE 31B-8 DEPTH MARKER LOCATIONS
TABLE 31B-7
1473 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31C – RADIATION
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31C – RADIATION
1475 CHAPTER 31C [DPH] RADIATION
SECTION 3101C SCOPE
SECTION 3102C RADIATION SHIELDING BARRIERS
SECTION 3103C MEDICAL RADIOGRAPHIC AND PHOTOFLUOROGRAPHIC INSTALLATIONS
SECTION 3104C MEDICAL THERAPEUTIC X-RAY INSTALLATIONS
1477 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31D – FOOD ESTABLISHMENTS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31D – FOOD ESTABLISHMENTS
1479 CHAPTER 31D [DPH] FOOD ESTABLISHMENTS
SECTION 3101D SCOPE
SECTION 3102D DEFINITION
SECTION 3103D BUILDINGS AND STRUCTURES
1481 CHAPTER 31E RESERVED
1483 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31F – MARINE OIL TERMINALS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31F – MARINE OIL TERMINALS
1485 CHAPTER 31F [SLC] MARINE OIL TERMINALS
DIVISION I
SECTION 3101F [SLC] INTRODUCTION
1486 EQUATION 1-1
TABLE 31F-1-1 MOT OIL SPILL EXPOSURE CLASSIFICATION
1488 DIVISION 2
SECTION 3102F AUDIT AND INSPECTION
TABLE 31F-2-1 MAXIMUM INTERVAL BETWEEN UNDERWATER INSPECTIONS (YEARS)1
1491 TABLE 31F-2-2 UNDERWATER INSPECTION LEVELS OF EFFORT [2.2]
TABLE 31F-2-3 SCOPE OF UNDERWATER INSPECTION [2.2]
1494 TABLE 31F-2-4 ASSESSMENT RATINGS
TABLE 31F-2-5 COMPONENT DEFICIENCY REMEDIAL ACTION PRIORITIES (RAP)
1495 TABLE 31F-2-6 FOLLOW-UP ACTIONS [2.2]
1498 TABLE 31F-2-7A
TABLE 31F-2-7B
1499 TABLE 31F-2-7C
1500 TABLE 31F-2-8
TABLE 31F-2-9 POST-EVENT RATINGS AND REMEDIAL ACTIONS [2.2]
1501 FIGURE 31F-2-1
1502 DIVISION 3
SECTION 3103F STRUCTURAL LOADING CRITERIA
TABLE 31F-3-1 UNIT WEIGHTS
TABLE 31F-3-2 EQUIPMENT AND PIPING AREA LOADS
1503 EQUATION 3-1
EQUATION 3-2
EQUATION 3-3
EQUATION 3-4
EQUATION 3-5
EQUATION 3-6
EQUATION 3-7
1504 TABLE 31F-3-3 VALUES OF Fa
TABLE 31F-3-4 VALUES OF Fv
1505 EQUATION 3-8
EQUATION 3-9
EQUATION 3-10
TABLE 31F-3-5 VALUES OF BS AND B1 [3.2]
1506 EQUATION 3-11
EQUATION 3-12
EQUATION 3-13
1507 FIGURE 31F-3-1 WIND SPEED CONVERSION FACTOR [3.5]
EQUATION 3-14
1508 FIGURE 31F-3-2 CURRENT VELOCITY CORRECTION FACTOR (p. 23 [3.6])
1509 TABLE 31F-3-6 TSUNAMI RUN-UP VALUES (ft) AND CURRENT SPEEDS (ft/sec) IN THE SAN FRANCISCO BAY AREA (AFTER [3.16])
EQUATION 3-15
EQUATION 3-16
EQUATION 3-17
EQUATION 3-18
1510 EQUATION 3-19
TABLE 31F-3-7 BERTHING VELOCITY Vn (NORMAL TO BERTH)1
EQUATION 3-20
1511 TABLE 31F-3-8 SITE CONDITIONS
TABLE 31F-3-9 BERTHING ANGLE
1512 TABLE 31F-3-10 LRFD LOAD FACTORS FOR LOAD COMBINATIONS [3.18]
TABLE 31F-3-11 SERVICE OR ASD LOAD FACTORS FOR LOAD COMBINATIONS [3.18]
1515 DIVISION 4
SECTION 3104F SEISMIC ANALYSIS AND STRUCTURAL PERFORMANCE
FIGURE 31F-4-1 DEFINITION OF IRREGULAR MOT
1516 TABLE 31F-4-1 SEISMIC PERFORMANCE CRITERIA1, 2
TABLE 31F-4-2 MINIMUM REQUIRED ANALYTICAL PROCEDURES
FIGURE 31F-4-2 PILE-DECK CONNECTION MODELING FOR PRESTRESSED CONCRETE PILE (ADAPTED FROM [4.2])
1517 FIGURE 31F-4-3 SIMPLIFIED SINGLE PILE MODEL OF A TIMBER PILE SUPPORTED STRUCTURE
EQUATION 4-1
FIGURE 31F-4-4 IDEALIZATION OF PUSHOVER CURVE (ADAPTED FROM [4.3])
EQUATION 4-2
EQUATION 4-3
1518 EQUATION 4-4
EQUATION 4-5
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
EQUATION 4-10
EQUATION 4-11
1519 EQUATION 4-12
EQUATION 4-13
EQUATOIN 4-14
EQUATION 4-15
FIGURE 31F-4-5 EFFECTIVE STIFFNESS FOR SUBSTITUTE STRUCTURE METHOD
FIGURE 31F-4-6 STIFFNESS FOR LINEAR MODAL ANALYSIS
1520 EQUATION 4-16
EQUATION 4-17
EQUATION 4-18
EQUATION 4-19
EQUATION 4-20
EQUATION 4-21
FIGURE 31F-4-7 PLAN VIEW OF WHARF SEGMENT UNDER X AND Y SEISMIC EXCITATIONS
FIGURE 31F-4-8 P-Δ EFFECT
1521 EQUATION 4-22
1522 EQUATION 4-23
1523 EQUATION 4-24
EQUATION 4-25
TABLE 31F-4-3 AMPLIFICATION FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
FIGURE 31F-4-9 AMPLIFICATION FACTOR, ap [4.10
TABLE 31F-4-4 IMPORTANCE FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
TABLE 31F-4-5 RESPONSE MODIFICATION FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
1524 EQUATION 4-26
1526 DIVISION 5
SECTION 3105F MOORING AND BERTHING ANALYSIS AND DESIGN
FIGURE 31F-5-1 TYPICAL PIER AND WHARF CONFIGURATIONS
1527 FIGURE 31F-5-2 HORIZONTAL LINE ANGLES [5.4]
FIGURE 31F-5-3 VERTICAL LINE ANGLES [5.4]
1528 EQUATION 5-1
FIGURE 31F-5-4 PASSING VESSEL
1529 FIGURE 31F-5-5 BERTHING ENERGY CAPACITY
TABLE 31F-5-1 CONTACT LENGTH
TABLE 31F-5-2 COEFFICIENT OF FRICTION
EQUATION 5-3
1530 TABLE 31F-5-3 SAFETY FACTORS FOR ROPES [5.4]
EQUATION 5-4
TABLE 31F-5-4 ALLOWABLE WORKING LOADS
1532 DIVISION 6
SECTION 3106F GEOTECHNICAL HAZARDS AND FOUNDATIONS
TABLE 31F-6-1 SITE CLASSES
1534 FIGURE 31F-6-1 AXIAL SOIL SPRINGS [6.8]
1535 FIGURE 31F-6-2 SLIDING LAYER MODEL [6.8]
1537 DIVISION 7
SECTION 3107F STRUCTURAL ANALYSIS AND DESIGN OF COMPONENTS
EQUATION 7-1A
EQUATION 7-1B
EQUATION 7-1C
EQUATION 7-2A
EQUATION 7-2B
EQUATION 7-2C
EQUATION 7-3A
EQUATION 7-3B
EQUATION 7-3C
1538 TABLE 31F-7-1 COMPRESSIVE STRENGTH OF STRUCTURAL CONCRETE
TABLE 31F-7-2 TENSILE AND YIELD PROPERTIES OF REINFORCING BARS FOR VARIOUS ASTM SPECIFICATIONS AND PERIODS
1539 TABLE 31F-7-3 EFFECTIVE ELASTIC STIFFNESS
FIGURE 31F-7-1 STRESS-STRAIN CURVES FOR CONFINED AND UNCONFINED CONCRETE [7.1]
FIGURE 31F-7-2 STRESS-STRAIN CURVE FOR MILD REINFORCING STEEL OR STRUCTURAL STEEL [7.1]
1540 FIGURE 31F-7-3 STRESS-STRAIN CURVE FOR PRESTRESSED STEEL [7.4]
EQUATION 7-4
EQUATION 7-5
EQUATION 7-6
EQUATION 7-7
TABLE 31F-7-4 PLASTIC HINGE LENGTH FOR PRESTRESSED CONCRETE PILES [7.5]
EQUATION 7-8
EQUATION 7-9
1541 TABLE 31F-7-5 LIMITS OF STRAIN
EQUATION 7-10
FIGURE 31F-7-4 METHOD A − MOMENT CURVATURE ANALYSIS
FIGURE 31F-7-5 METHOD B – MOMENT CURVATURE ANALYSIS [7.6]
EQUATION 7-11
EQUATION 7-12
1542 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
EQUATION 7-16
EQUATION 7-17
EQUATION 7-18
FIGURE 31F-7-6 CONCRETE SHEAR MECHANISM
1543 FIGURE 31F-7-7 TRANSVERSE SHEAR MECHANISM
EQUATION 7-19
EQUATION 7-20
FIGURE 31F-7-8 AXIAL FORCE SHEAR MECHANISM
EQUATION 7-21
TABLE 31F-7-6 PLASTIC HINGE LENGTH FOR STEEL PILES
1544 TABLE 31F-7-7 STRUCTURAL STEEL STRAIN LIMITS, εu
EQUATION 7-22
EQUATION 7-23
FIGURE 31F-7-9 DEVELOPMENT LENGTH
EQUATION 7-24
EQUATION 7-25
FIGURE 31F-7-10 DEGRADATION OF EFFECTIVE PRINCIPAL TENSION STRENGTH WITH JOINTSHEAR STRAIN (rotation) [7.1, pg. 564]
EQUATION 7-26
EQUATION 7-27
1545 FIGURE 31F-7-11 REDUCED PILE MOMENT CAPACITY
EQUATION 7-28
EQUATION 7-29
FIGURE 31F-7-12 JOINT ROTATION
EQUATION 7-30
EQUATION 7-31
EQUATION 7-32
FIGURE 31F-7-13 EQUIVALENT PILE CURVATURE
1546 EQUATION 7-33
EQUATION 7-34
FIGURE 31F-7-14 PUSHOVER CURVE FOR ORDINARY BATTER PILES
1548 EQUATION 7-35
FIGURE 31F-7-15 ASSUMED IN-GROUND FIXITY
TABLE 31F-7-8 DISTANCE BELOW GROUND TO POINT OF FIXITY
EQUATION 7-36
EQUATION 7-37
EQUATION 7-38
EQUATION 7-39
TABLE 31F-7-9 LIMITING STRAIN VALUES FOR TIMBER
EQUATION 7-40
EQUATION 7-41
EQUATION 7-42
1552 DIVISION 8
SECTION 3108F FIRE PREVENTION, DETECTION AND SUPPRESSION
1553 TABLE 31F-8-1 CARGO LIQUID VOLATILITY RATINGS
TABLE 31F-8-2 FIRE HAZARD CLASSIFICATIONS
1554 TABLE 31F-8-3 MINIMUM FIRE SUPPRESSION PROVISIONS (N/E)
1556 DIVISION 9
SECTION 3109F PIPING AND PIPELINES
1557 TABLE 31F-9-1 COEFFICIENTS OF STATIC FRICTION
1559 DIVISION 10
SECTION 3110F MECHANICAL AND ELECTRICAL EQUIPMENT
1562 DIVISION 11
SECTION 3111F ELECTRICAL SYSTEMS
1565 DIVISION 12
SECTION 3112F REQUIREMENTS SPECIFIC TO MARINE TERMINALS THAT TRANSFER LNG
1567 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 32 – ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 32 – ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
1569 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
1571 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 33 – SAFEGUARDS DURING CONSTRUCTION
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 33 – SAFEGUARDS DURING CONSTRUCTION
1573 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3303 DEMOLITION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3304 SITE WORK
CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
1574 SECTION 3306 PROTECTION OF PEDESTRIANS
SECTION 3305 SANITARY
SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
1575 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
1576 SECTION 3309 FIRE EXTINGUISHERS
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3310 MEANS OF EGRESS
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3311 STANDPIPES
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
1577 SECTION 3314 FIRE WATCH DURING CONSTRUCTION
SECTION 3314 FIRE WATCH DURING CONSTRUCTION
1579 CHAPTER 34 RESERVED
CHAPTER 34 RESERVED
1581 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS
1582 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS—continued
1585 CHAPTER 35 REFERENCED STANDARDS
1604 AWC
AWCI
AWPA
AWS
1605 BHMA
CEN
CPA
CPSC
1606 CSA
CSSB
DASMA
DHA
DOC
1607 DOL
DOTn
EN
FEMA
FM
1608 GA
ICC
1622 PCI
1623 PTI
RMI
SBCA
SDI
SFM
1624 SJI
SPRI
SRCC
TIA
1625 TMS
TPI
UBC
UL
1629 ULC
USC
WCLIB
WDMA
WRI
1631 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX A – EMPLOYEE QUALIFICATIONS
APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
SECTION A102 REFERENCED STANDARDS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX A – EMPLOYEE QUALIFICATIONS
APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
SECTION A102 REFERENCED STANDARDS
TABLE A102.1 REFERENCED STANDARDS
1633 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX B – BOARD OF APPEALS
APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX B – BOARD OF APPEALS
APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
1635 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX C – GROUP U – AGRICULTURAL BUILDINGS
APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX C – GROUP U – AGRICULTURAL BUILDINGS
APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
1636 SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
1637 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX D – FIRE DISTRICTS
APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX D – FIRE DISTRICTS
APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
1638 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
1639 SECTION D106 REFERENCED STANDARDS
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
SECTION D106 REFERENCED STANDARDS
TABLE D106.1 REFERENCED STANDARDS
1641 APPENDIX E
APPENDIX E RESERVED
1643 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX F – RODENTPROOFING
APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX F – RODENTPROOFING
APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
1645 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX G – FLOOD-RESISTANT CONSTRUCTION
APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX G – FLOOD-RESISTANT CONSTRUCTION
APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
1646 SECTION G102 DEFINITIONS
SECTION G104 POWERS AND DUTIES
SECTION G103 APPLICABILITY
SECTION G102 DEFINITIONS
SECTION G103 APPLICABILITY
SECTION G104 POWERS AND DUTIES
1647 SECTION G105 PERMITS
SECTION G105 PERMITS
1648 SECTION G106 VARIANCES
SECTION G106 VARIANCES
1649 SECTION G107 SUBDIVISIONS
SECTION G109 MANUFACTURED HOMES
SECTION G108 SITE IMPROVEMENT
SECTION G107 SUBDIVISIONS
SECTION G108 SITE IMPROVEMENT
SECTION G109 MANUFACTURED HOMES
1650 SECTION G110 RECREATIONAL VEHICLES
SECTION G113 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G111 TANKS
SECTION G112 OTHER BUILDING WORK
SECTION G114 UTILITY AND MISCELLANEOUS GROUP U
SECTION G110 RECREATIONAL VEHICLES
SECTION G111 TANKS
SECTION G112 OTHER BUILDING WORK
SECTION G113 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G114 UTILITY AND MISCELLANEOUS GROUP U
1651 SECTION G115 REFERENCED STANDARDS
SECTION G115 REFERENCED STANDARDS
TABLE G115.1 REFERENCED STANDARDS
1653 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX H – SIGNS
APPENDIX H SIGNS
SECTION H102 DEFINITIONS
SECTION H101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX H – SIGNS
APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
1654 SECTION H106 ELECTRICAL
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
1655 SECTION H110 ROOF SIGNS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
SECTION H111 WALL SIGNS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
1656 SECTION H112 PROJECTING SIGNS
SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
SECTION H115 THICKNESS OF SIGNS
SECTION H112 PROJECTING SIGNS
SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
SECTION H115 THICKNESS OF SIGNS
TABLE H115.1(1) SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
1657 SECTION H116 REFERENCED STANDARDS
TABLE H115.1(2) THICKNESS OF PROJECTION SIGN
SECTION H116 REFERENCED STANDARDS
TABLE H116.1 REFERENCED STANDARDS
1659 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX I – PATIO COVERS
APPENDIX I PATIO COVERS
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I101 GENERAL
SECTION I102 DEFINITION
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX I – PATIO COVERS
APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
1660 SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
1661 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX J – GRADING
APPENDIX J GRADING
SECTION J102 DEFINITIONS
SECTION J101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX J – GRADING
APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
1662 SECTION J103 PERMITS REQUIRED
SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
SECTION J103 PERMITS REQUIRED
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
1663 SECTION J107 FILLS
SECTION J108 SETBACKS
SECTION J107 FILLS
FIGURE J107.3 BENCHING DETAILS
SECTION J108 SETBACKS
1664 SECTION J109 DRAINAGE AND TERRACING
FIGURE J108.1 DRAINAGE DIMENSIONS
SECTION J109 DRAINAGE AND TERRACING
1665 SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
TABLE J111.1 REFERENCED STANDARDS
1667 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX K – GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED BY THE FACILITIES
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX K – GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
APPENDIX K GROUP R-3 AND GROUP R-3.1 OCCUPANCIES PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
SECTION K101 SCOPE
SECTION K102 DEFINITIONS
1668 SECTION K103 STRUCTURAL STABILITY
SECTION K104 EVACUATION LOCATIONS
SECTION K105 SPACE WITHIN THE BUILDING
1669 SECTION K106 DECKS AND BALCONIES THAT ARE EVACUATION LOCATIONS
SECTION K107 ROOFTOP EVACUATION LOCATIONS
SECTION K108 ATTICS THAT ARE EVACUATION LOCATIONS
SECTION K109 ALTERNATE MEANS OF PROTECTION
1671 FIGURE K103.1 N.T.S.
1672 FIGURE K103.1 N.T.S.
1673 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX L – EARTHQUAKE RECORDING INSTRUMENTATION
APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX L – EARTHQUAKE RECORDING INSTRUMENTATION
APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
1675 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX M – TSUNAMI-GENERATED FLOOD HAZARD
APPENDIX M TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M101 REFUGE STRUCTURES FOR VERTICAL EVACUATION FROM TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M102 REFERENCED STANDARDS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX M – TSUNAMI-GENERATED FLOOD HAZARD
APPENDIX M TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M101 REFUGE STRUCTURES FOR VERTICAL EVACUATION FROM TSUNAMI-GENERATED FLOOD HAZARDS
SECTION M102 REFERENCED STANDARDS
TABLE M102.1 REFERENCED STANDARDS
1677 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX N – REPLICABLE BUILDINGS
APPENDIX N REPLICABLE BUILDINGS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX N – REPLICABLE BUILDINGS
APPENDIX N REPLICABLE BUILDINGS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
1678 SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
1679 SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
1681 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX O – PERFORMANCE-BASED APPLICATION
[A] APPENDIX O PERFORMANCE-BASED APPLICATION
[A] SECTION O101 GENERAL
CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX O – PERFORMANCE-BASED APPLICATION
[A] APPENDIX O PERFORMANCE-BASED APPLICATION
[A] SECTION O101 GENERAL
1683 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE APPENDIX P – EMERGENCY HOUSING
APPENDIX P EMERGENCY HOUSING
SECTION P101 GENERAL
SECTION P102 DEFINITIONS
1684 SECTION P103 EMERGENCY HOUSING
SECTION P104 EMERGENCY SLEEPING CABINS
1685 SECTION P105 EMERGENCY TRANSPORTABLE HOUSING UNITS
SECTION P106 TENTS AND MEMBRANE STRUCTURES
SECTION P107 ACCESSIBILITY
SECTION P108 LOFTS IN EMERGENCY HOUSING
1686 SECTION P109 LOCATION, MAINTENANCE AND IDENTIFICATION
SECTION P110 EMERGENCY HOUSING FACILITIES
1689 INDEX
ACCESS OPENINGS
ACCESSIBILITY
INDEX
1690 ACCESSORY OCCUPANCIES
ADDITION.
ADDRESS IDENTIFICATION.
ADJUSTED CONSTRUCTION COSTS
ADMINISTRATION
ADOBE CONSTRUCTION
AEROSOL PRODUCTS
AGGREGATE
AGRICULTURAL BUILDINGS (see GROUP U).
AIR CONDITIONING (see MECHANICAL) AIRCRAFT HANGARS.
AIRCRAFT MANUFACTURING FACILITIES
AIRCRAFT-RELATED OCCUPANCIES
ACCESSIBLE MEANS OF EGRESS.
1691 ALTERNATIVE MATERIALS, DESIGN AND METHODS
ALUMINUM
AIR-INFLATED OR AIR-SUPPORTED STRUCTURES
AMBULATORY CARE FACILITIES
AISLE
AMUSEMENT AREA, SPECIAL
ALARM SYSTEMS, EMERGENCY
AMUSEMENT PARK STRUCTURES
ALARMS, FIRE (see FIRE ALARM AND SMOKE DETECTION SYSTEMS) ALARMS, VISIBLE
ANCHOR BUILDING (see COVERED MALL AND OPEN MALL BUILDING)
ANCHORAGE
ALARMS, VOICE
ALLOWABLE STRESS DESIGN
APARTMENT HOUSES
APPEALS
ALTERATIONS
APPROVED AGENCY.
ALTERNATING TREAD DEVICES.
1692 ARCHITECT (see definitions for REGISTERED DESIGN PROFESSIONAL and REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE) ARCHITEC
AREA, BUILDING.
AREA FOR ASSISTED RESCUE, EXTERIOR (see EXTERIOR AREA FOR ASSISTED RESCUE) AREA OF REFUGE (see also ACCESSIBLE MEANS OF EGRESS).
ASSEMBLY OCCUPANCY (GROUP A)
ASSISTED LIVING (see GROUP I-1 and GROUP R-4)
ATMOSPHERIC ICE LOADS
1693 ATRIUM.
BARBECUES
BARRIERS
BASEMENT (see UNDERGOUND BUILDINGS)
ATTIC
AUDITORIUM (see ASSEMBLY OCCUPANCY)
BASEMENT WALLS
BATH AND BATHING ROOMS (see TOILETS AND TOILET ROOMS)
AUTOMOBILE PARKING GARAGE (see GARAGE, AUTOMOBILE PARKING) AWNINGS
BAY AND ORIEL WINDOWS
BLEACHERS.
BLOCK (see CONCRETE BLOCK AND GLASS UNIT MASONRY) BOARD OF APPEALS
1731 HISTORY NOTE APPENDIX
1733 ICC EVALUATION SERVICE
1734 S.K. GHOSH ASSOCIATES LLC, SEISMIC AND BUILDING CODE CONSULTING
CA Building Code Volumes 1 2 2022 1stptg
$141.25