Shopping Cart

No products in the cart.

CA BuildingCode Vol 1 2016

$153.83

California Building Code, Title 24 Part 2, Volume 1 (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2016 835
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies). This 2-volume set is a fully integrated code based on the 2015 International Building Code®. The CBC includes: Title 24, Part 8 California Historical Building Code (CHBC): contains regulations of the State Historical Building Safety Board. Provisions contained in the CHBC provide for the preservation, restoration, rehabilitation, relocation, or reconstruction of buildings or structures designated as qualified historical buildings or properties. The CHBC contains alternative solutions for the preservation of qualified historical buildings or properties, to provide access for persons with disabilities, to provide a cost-effective approach to preservation, and to provide for the reasonable safety of the occupants or users. Title 24, Part 10 California Building Standards Commission (CBSC): adopts certain provisions of the International Existing Building Code, Appendix Chapter A1, Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings. Effective Date: January 1, 2017.

PDF Catalog

PDF Pages PDF Title
1 2016 CALIFORNIA BUILDING CODE VOLUME 1 of 2
2 2016 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGUALTIONS TITLE 24, PART 2 VOLUME 1 OF 2 TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
5 CALIFORNIA CODE OF REGULATIONS, TITLE 24
6 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
7 CALIFORNIA MATRIX ADOPTION TABLES
9 MARGINAL MARKINGS
CODE DEVELOPMENT COMMITTEE RESPONSIBILITIES
11 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
22 TABLE OF CONTENTS
36 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION
37 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued
38 CHAPTER 1 SCOPE AND ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
40 SECTION 1.2 BUILDING STANDARDS COMMISSION
42 SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS
SECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
43 SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
44 SECTION 1.8.3 LOCAL ENFORCING AGENCY
45 SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
46 SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
47 SECTION 1.8.8 APPEALS BOARD
SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
48 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
50 SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT
52 SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
56 SECTION 1.12 STATE LIBRARIAN
SECTION 1.13 RESERVED
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION
58 DIVISION II SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
59 SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
61 SECTION 105 PERMITS
63 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
65 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
66 SECTION 111 CERTIFICATE OF OCCUPANCY
67 SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
68 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
70 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
71 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
72 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
73 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
74 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
75 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
76 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
77 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
78 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
79 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
80 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
126 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION
128 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
129 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
130 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
132 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
133 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
134 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
135 SECTION 308 INSTITUTIONAL GROUP I
136 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
138 SECTION 311 STORAGE GROUP S
139 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM]
SECTION 314 ORGANIZED CAMPS GROUP C [SFM]
140 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY
141 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
142 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
143 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
144 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
147 EQUATION 4-1
148 SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS
149 TABLE 403.2.4 MINIMUM BOND STRENGTH
151 SECTION 404 ATRIUMS
152 SECTION 405 UNDERGROUND BUILDINGS
153 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
155 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
157 SECTION 407 GROUP I-2
162 SECTION 408 GROUP I-3
167 SECTION 409 MOTION PICTURE PROJECTION ROOMS
SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
169 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
170 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
171 [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
173 TABLE 412.7 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
174 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
175 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
176 [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
177 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
179 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
181 [F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
187 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
188 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS R-1, R-2, R-2.1, R-3, R-3.1 AND R-4
189 SECTION 421 HYDROGEN FUEL GAS ROOMS
190 SECTION 422 AMBULATORY CARE FACILITIES
SECTION 423 STORM SHELTERS
SECTION 424 CHILDREN’S PLAY STRUCTURES
191 SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
192 SECTION 435 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM]
195 SECTION 436 GROUP I-4 [SFM]
196 SECTION 437 RESERVED
SECTION 438 RESERVED
SECTION 439 ROAD TUNNELS, BRIDGES, AND OTHER LIMITED-ACCESS HIGHWAYS [SFM]
SECTION 440 HORSE RACING STABLES [SFM]
SECTION 441 PET KENNELS [SFM]
SECTION 442 COMBUSTION ENGINES AND GAS TURBINES [SFM]
SECTION 443 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS [SFM]
197 SECTION 444 EXPLOSIVES [SFM]
SECTION 445 RESERVED
SECTION 446 WINERY CAVES [SFM]
198 SECTION 447 RESERVED
SECTION 448 RESERVED
SECTION 449 PUBLIC LIBRARIES [SL AND SFM]
SECTION 450 GROUP C [SFM]
201 SECTION 451 RESERVED
SECTION 452 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE
202 SECTION 453 GROUP L [SFM]
204 TABLE 453.7.3.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
205 SECTION 454 RESERVED
SECTION 455 LARGE FAMILY DAY-CARE HOMES [SFM]
208 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
209 SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
FIGURE 5-1
210 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
211 TABLE 504.3a, i ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
212 TABLE 504.4a, b, n ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
213 TABLE 504.4a, b, n—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
214 SECTION 506 BUILDING AREA
EQUATION 5-1
215 TABLE 506.2a, b, i ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
216 TABLE 506.2a, b, i—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
217 TABLE 506.2a, b, i—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
218 EQUATION 5-2
EQUATION 5-3
EQUATION 5-4
219 EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
221 SECTION 508 MIXED USE AND OCCUPANCY
222 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 509 INCIDENTAL USES
223 TABLE 509 INCIDENTAL USES
SECTION 510 SPECIAL PROVISIONS
226 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
227 TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
228 TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES
229 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
232 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
233 SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
234 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
236 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
237 EQUATION 7-1
FIGURE 705.7 EQUIVALENT OPENING FACTOR
238 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
240 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
242 SECTION 707 FIRE BARRIERS
243 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
244 SECTION 708 FIRE PARTITIONS
245 SECTION 709 SMOKE BARRIERS
246 SECTION 710 SMOKE PARTITIONS
SECTION 711 HORIZONTAL ASSEMBLIES
247 SECTION 712 VERTICAL OPENINGS
248 SECTION 713 SHAFT ENCLOSURES
250 SECTION 714 PENETRATIONS
252 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
253 SECTION 716 OPENING PROTECTIVES
254 TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
255 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
256 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
258 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
259 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
260 TABLE 717.3.2.1 FIRE DAMPER RATING
264 SECTION 718 CONCEALED SPACES
267 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
268 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
270 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
271 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
272 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
273 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
274 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
275 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
276 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
277 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
278 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
279 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
280 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
281 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
282 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
283 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
284 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
285 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
286 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
287 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
288 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
289 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
290 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
291 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
292 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
293 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
EQUATION 7-4
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
294 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
295 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
296 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
297 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
298 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
FIGURE 722.2.2.3 (2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
299 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTH
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
300 EQUATION 7-6
301 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
302 EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
303 EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
304 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
305 FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
EQUATION 7-13
306 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-14
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-15
307 EQUATION 7-16
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
308 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
309 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
310 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
311 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
312 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
313 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
314 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
315 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
316 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
317 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
318 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
320 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION 701A SCOPE, PURPOSE AND APPLICATION
321 SECTION 702A DEFINITIONS
322 SECTION 703A STANDARDS OF QUALITY
323 SECTION 704A IGNITION-RESISTANT CONSTRUCTION
SECTION 705A ROOFING
SECTION 706A VENTS
324 SECTION 707A EXTERIOR COVERING
326 SECTION 708A EXTERIOR WINDOWS AND DOORS
SECTION 709A DECKING
SECTION 710A ACCESSORY STRUCTURES
328 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
CHAPTER 8 INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
329 SECTION 803 WALL AND CEILING FINISHES
330 TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
331 SECTION 804 INTERIOR FLOOR FINISH
332 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
333 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
334 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS
335 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
336 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
337 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
338 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
339 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
340 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
341 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
343 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
346 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
350 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
352 SECTION 905 STANDPIPE SYSTEMS
354 SECTION 906 PORTABLE FIRE EXTINGUISHERS
355 [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
356 [F] TABLE 906.3(2)FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
372 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
374 SECTION 908 EMERGENCY ALARM SYSTEMS
375 SECTION 909 SMOKE CONTROL SYSTEMS
377 EQUATION 9-1
378 EQUATION 9-3
384 SECTION 910 SMOKE AND HEAT REMOVAL
EQUATION 9-4
EQUATION 9-5
385 SECTION 911 FIRE COMMAND CENTER
386 SECTION 912 FIRE DEPARTMENT CONNECTIONS
387 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
388 SECTION 915 CARBON MONOXIDE DETECTION
390 SECTION 916 EMERGENCY RESPONDER RADIO COVERAGE
392 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
393 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
394 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
395 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
396 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
397 SECTION 1003 GENERAL MEANS OF EGRESS
398 SECTION 1004 OCCUPANT LOAD
399 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 MEANS OF EGRESS SIZING
401 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
402 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
403 TABLE 1006.3.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 AND R-3 OCCUPANCIES
404 TABLE 1006.3.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
405 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
408 SECTION 1010 DOORS, GATES AND TURNSTILES
410 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.1.4(2)MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
417 SECTION 1011 STAIRWAYS
420 SECTION 1012 RAMPS
421 SECTION 1013 EXIT SIGNS
423 SECTION 1014 HANDRAILS
424 SECTION 1015 GUARDS
426 SECTION 1016 EXIT ACCESS
427 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1018 AISLES
428 SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
SECTION 1020 CORRIDORS
429 TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
430 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
431 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
433 SECTION 1024 EXIT PASSAGEWAYS
SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
435 SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
436 SECTION 1028 EXIT DISCHARGE
437 SECTION 1029 ASSEMBLY
439 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
442 TABLE 1029.12.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
444 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
446 CHAPTER 11 RESERVED
448 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY
450 CHAPTER 11A HOUSING ACCESSIBILITY
DIVISION I – APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY
451 SECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS
452 SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS
453 DIVISION II – EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES
455 SECTION 1110A EXTERIOR ACCESSIBLE ROUTES
456 SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES
457 SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
458 SECTION 1115A EXTERIOR STAIRWAYS
459 SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES
460 DIVISION III – BUILDING FEATURES
SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY
SECTION 1118A EGRESS AND AREAS OF REFUGE
SECTION 1119A INTERIOR ACCESSIBLE ROUTES
461 SECTION 1120A RESERVED
SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
462 SECTION 1123A INTERIOR STAIRWAYS
463 SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
464 TABLE 1124A.3.2 ELEVATOR CAR DIMENSIONS
465 SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
466 SECTION 1126A DOORS, GATES AND WINDOWS
468 SECTION 1127A COMMON USE FACILITIES
475 DIVISION IV – DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS
476 SECTION 1133A KITCHENS
478 SECTION 1134A BATHING AND TOILET FACILITIES
481 SECTION 1135A LAUNDRY ROOMS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
482 DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS
SECTION 1137A OTHER FEATURES AND FACILITIES
SECTION 1138A SPACE ALLOWANCES AND REACH RANGES
484 SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS
485 SECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS
486 SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE
487 TABLE 1143A.5 VISUAL CHARACTER HEIGHT
488 TABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED
489 DIVISION VI – SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1—INDIVIDUAL BUILDING TEST
TEST NO. 2—SITE ANALYSIS TEST
490 TEST NO. 3—UNUSUAL CHARACTERISTICS TEST
491 DIVISION VII – FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL
492 FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION
493 FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS
494 FIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH
495 FIGURE 11A-1F CHANGE IN LEVEL
496 FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS
497 FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES
498 FIGURE 11A-1I FORWARD REACH
499 FIGURE 11A-1J SIDE REACH
500 FIGURE 11A-1K MINIMUM CLEARANCES FOR SEATING AND TABLE
501 FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE
502 FIGURE 11A-2A DOUBLE PARKING STALLS
FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS
503 FIGURE 11A-2C DIAGONAL PARKING STALLS
504 FIGURE 11A-3A CURB DETAILS
505 FIGURE 11A-3B CURB DETAIL
506 FIGURE 11A-3C CURB DETAIL
507 FIGURE 11A-3D CURB DETAIL
FIGURE 11A-3E CURB DETAIL
508 FIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60″ WIDE
FIGURE 11A-3G CURB DETAIL
509 FIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL
510 FIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL
511 FIGURE 11A-3L CURB SECTIONS
512 FIGURE 11A-5A RAMPS AND SIDEWALKS
513 FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS
514 FIGURE 11A-6B HANDRAILS
515 FIGURE 11A-6C RAMP DIMENSIONS
516 FIGURE 11A-6D RAMP LANDING AND DOORWAY
517 FIGURE 11A-6E STAIR HANDRAILS
518 FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS
519 FIGURE 11A-7B ELEVATOR CONTROL PANEL
520 FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION
521 FIGURE 11A-8A MANEUVERING CLEARANCE AT SWINGING DOORS
522 FIGURE 11A-8B MANEUVERING CLEARANCE AT DOORWAYS, SLIDING DOORS, AND FOLDING DOORS
523 FIGURE 11A-8C MANEUVERING CLEARANCES AT RECESSED DOORS
524 FIGURE 11A-8G VESTIBULE
525 FIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY
526 FIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR
527 FIGURE 11A-9A TOILET FACILITIES
528 FIGURE 11A-9B WATER CLOSETS
529 FIGURE 11A-9C GRAB BARS
530 FIGURE 11A-9D KNEE AND TOE SPACE
531 FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS
532 FIGURE 11A-9F GRAB BARS AT BATHTUBS
533 FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS
534 FIGURE 11A-9H STANDARD ROLL-IN SHOWER
535 FIGURE 1A-9I SHOWER SEATS AND GRAB BARS
536 FIGURE 11A-9J OPEN SHOWER
537 FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER
538 FIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET
539 FIGURE 11A-10A KITCHEN SPECIFICATIONS
540 FIGURE 11A-11A DRINKING FOUNTAINS
541 FIGURE 11A-11B TELEPHONES
542 FIGURE 11A-11C INTERNATIONAL TTY SYMBOL
FIGURE 11A-11D VOLUME CONTROL TELEPHONES
FIGURE 11A-11E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
544 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,COMMERCIAL BUILDINGS AND PUBLIC HOUSING
546 CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
548 11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES
549 DIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES
551 11B-203 GENERAL EXCEPTIONS
552 11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
11B-206 ACCESSIBLE ROUTES
556 11B-207 ACCESSIBLE MEANS OF EGRESS
557 11B-208 PARKING SPACES
TABLE 11B-208.2 PARKING SPACES
558 11B-209 PASSENGER DROP OFF AND LOADING ZONE AND BUS STOPS
11B-210 STAIRWAYS
559 11B-211 DRINKING FOUNTAINS
11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS
11B-213 TOILET FACILITIES AND BATHING FACILITIES
560 11B-214 WASHING MACHINES AND CLOTHES DRYERS
11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS
11B-216 SIGNS
562 11B-217 TELEPHONES
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES
563 11B-218 TRANSPORTATION FACILITIES
11B-219 ASSISTIVE LISTENING SYSTEMS
564 11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT OF SALE DEVICES
11B-221 ASSEMBLY AREAS
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
566 11B-222 DRESSING, FITTING AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONGTERM CARE FACILITIES
567 11B-224 TRANSIENT LODGING GUEST ROOMS, HOUSING AT A PLACE OF EDUCATION AND SOCIAL SERVICE CENTER ESTABLISHMENTS
TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES
568 TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES
11B-225 STORAGE
569 TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES
11B-226 DINING SURFACES AND WORK SURFACES
11B-227 SALES AND SERVICE
TABLE 11B-227.2 CHECK-OUT AISLES
11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, FUEL DISPENSERS, AND ELECTRIC VEHICLE CHARGING STATIONS
570 TABLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC USE AND COMMON USE
11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATION SYSTEMS
11B-231 JUDICIAL FACILITIES
571 11B-232 DETENTION FACILITES AND CORRECTIONAL FACILITIES
572 11B-233 RESIDENTIAL FACILITIES
573 11B-234 AMUSEMENT RIDES
574 11B-235 RECREATIONAL BOATING FACILITIES
TABLE 11B-235.2 BOAT SLIPS
11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
11B-240 PLAY AREAS
575 TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS
576 11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
11B-244 RELIGIOUS FACILITIES
11B-245 PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RESIDENCES
11B-246 OUTDOOR DEVELOPED AREAS
577 11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
578 DIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL
11B-304 TURNING SPACE
579 FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
580 FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE
FIGURE 11B-306.3 KNEE CLEARANCE
581 11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS
582 FIGURE 11B-307.4 VERTICAL CLEARANCE
FIGURE 11B-307.4.1 GUY BRACES
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH
583 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
TABLE 11B-308.4 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-309 OPERABLE PARTS
584 DIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
585 FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS, AND GATES
586 FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
587 FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
588 FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
589 TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
590 FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES
592 11B-405 RAMPS
593 FIGURE 11B-405.7 RAMP LANDINGS
FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
594 FIGURE 11B-406.2.2 SIDES OF CURB RAMPS
FIGURE 11B-406.3.2 PARALLEL CURB RAMPS
FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS
595 FIGURE 11B-406.5.8 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 11B-406.6 ISLANDS IN CROSSINGS
11B-407 ELEVATORS
596 FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS
597 FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES
TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
598 FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
599 TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION
600 11B-408 LIMITED USE LIMITED APPLICATION ELEVATORS
601 FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
602 FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL
11B-410 PLATFORM LIFTS
FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES
11B-411 DESTINATION-ORIENTED ELEVATORS
603 FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION
606 FIGURE 11B-411.2.3 FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES
608 DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES
609 FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE
610 FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION
611 11B-503 PASSENGER DROP OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE
612 11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS
613 FIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION
614 FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS
615 DIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS
616 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS
617 FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7 DISPENSER OUTLET LOCATION
618 FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR
619 FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR
FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS
620 FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT
621 TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-605 URINALS
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS
11B-606 LAVATORIES AND SINKS
622 11B-607 BATHTUBS
FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS
623 FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS
624 FIGURE 11B-607.5 BATHTUB CONTROL LOCATION
11B-608 SHOWER COMPARTMENTS
FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
625 FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER
FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
626 FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
627 11B-610 SEATS
FIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
628 FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS
FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS
629 DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS
630 TABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
631 FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT
632 FIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY
FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
633 FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.6.4 EDGES AND VERTICES ON GEOMETRIC SYMBOLS
634 TABLE 11B-703.8.4 LOW RESOLUTION VMS CHARACTER HEIGHT
TABLE 11B-703.8.5 PIXEL COUNT FOR LOW RESOLUTION VMS
FIGURE 11B-703.8.5 LOW RESOLUTION VMS CHARACTERS
635 11B-704 TELEPHONES
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
636 FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES
637 FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT OF SALE DEVICES
638 FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT
639 11B-708 TWO WAY COMMUNICATION SYSTEMS
640 DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI AMBULANT SEATS
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
641 FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING AND LOCKER ROOMS
11B-804 KITCHENS, KITCHENETTES, AND WET BARS
642 FIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS
643 11B-805 MEDICAL CARE AND LONG-TERM CARE FACILITIES
644 11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS
645 11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS
646 11B-810 TRANSPORTATION FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS
647 FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE
11B-812 ELECTRIC VEHICLE CHARGING STATIONS
649 FIGURE 11B-812.9. SURFACE MARKING
650 DIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK OUT AISLES AND SALES AND SERVICE COUNTERS
651 FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS
652 DIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
653 11B-1003 RECREATIONAL BOATING FACILITIES
654 FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
655 FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
11B-1004 EXERCISE MACHINES AND EQUIPMENT
656 11B-1005 FISHING PIERS AND PLATFORMS
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILITIES
657 11B-1007 MINIATURE GOLF FACILITIES
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
11B-1008 PLAY AREAS
658 FIGURE 11B-1008.3.1 TRANSFER PLATFORMS
659 FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS, AND SPAS
FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
660 FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
661 FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT
662 FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
663 FIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
664 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT
666 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
667 TABLE 1203.3 INSULATION FOR CONDENSATION CONTROL
668 SECTION 1204 TEMPERATURE CONTROL
669 SECTION 1205 LIGHTING
SECTION 1206 YARDS OR COURTS
670 SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
671 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
672 SECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
SECTION 1212 [HCD 1] POLLUTANT CONTROL
SECTION 1213 RESERVED
SECTION 1214 RESERVED
SECTION 1215 RESERVED
SECTION 1216 RESERVED
SECTION 1217 RESERVED
SECTION 1218 RESERVED
SECTION 1219 RESERVED
SECTION 1220 RESERVED
SECTION 1221 RESERVED
SECTION 1222 RESERVED
SECTION 1223 RESERVED
673 SECTION 1224 [OSHPD 1] HOSPITALS
677 TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR1
678 TABLE 1224.4.6.5 [OSHPD 1, 2, 3 & 4] LOCATION OF NURSE CALL DEVICES KEY: • Required
680 TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS
683 TABLE 1224.4.19 SOUND TRANSMISSION LIMITATIONS IN HOSPITALS
711 SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES
720 SECTION 1226 [OSHPD 3] CLINICS
731 SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS
736 SECTION 1228 RESERVED
SECTION 1229 RESERVED
SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES
738 TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
740 SECTION 1231 [BSCC] LOCAL DETENTION
742 TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
746 SECTION 1232 RESERVED
SECTION 1233 RESERVED
SECTION 1234 RESERVED
SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS)
747 SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS
SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES
SECTION 1238 RESERVED
SECTION 1239 RESERVED
SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS
749 TABLE 1240.15.1
SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES
SECTION 1242 [AGR] RENDERERS
SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS
750 SECTION 1244 RESERVED
SECTION 1245 RESERVED
SECTION 1246 RESERVED
SECTION 1247 RESERVED
SECTION 1248 RESERVED
SECTION 1249 RESERVED
SECTION 1250 [CA] PHARMACIES
751 SECTION 1251 [CA] VETERINARY FACILITIES
SECTION 1252 [CA] BARBER COLLEGES AND SHOPS
SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS
752 SECTION 1254 [CA] ACUPUNCTURE OFFICES
754 CHAPTER 13 ENERGY EFFICIENCY Refer to California Energy Code, Title 24, Part 6.
756 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS
CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
757 SECTION 1403 PERFORMANCE REQUIREMENTS
758 SECTION 1404 MATERIALS
SECTION 1405 INSTALLATION OF WALL COVERINGS
759 TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
760 TABLE 1405.3.2 CLASS III VAPOR RETARDERS
764 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
765 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
767 TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
768 SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
769 SECTION 1410 PLASTIC COMPOSITE DECKING
SECTION 1411 [DSA-SS & DSA-SS/CC, OSHPD 1 & 4] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER
770 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
771 SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
772 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
774 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D7158a
TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D3161
775 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
776 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
778 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
780 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
781 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
782 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
783 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
784 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
785 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
786 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
789 SECTION 1511 REROOFING
790 SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
SECTION 1513 [DSA-SS & DSA-SS/CC, OSHPD 1 & 4] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS
792 INDEX
832 HISTORY NOTE APPENDIX
CA BuildingCode Vol 1 2016
$153.83