CA BuildingCode Vol 1 2019
$83.42
California Building Code, Title 24, Part 2, Volume 1 (W/ ERRATA & SUPPLEMENT)
Published By | Publication Date | Number of Pages |
CA | 2019 | 869 |
“The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies).
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2019 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 |
2 | 2019 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2 VOLUME 1 OF 2 TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE ACKNOWLEDGEMENTS |
5 | CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST |
6 | HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS |
7 | CALIFORNIA MATRIX ADOPTION TABLES |
12 | EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE |
22 | TABLE OF CONTENTS |
36 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION |
37 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued |
38 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued |
40 | CHAPTER 1 SCOPE AND ADMINISTRATION DIVISION I CALIFORNIA ADMINISTRATION SECTION 1.1 GENERAL |
43 | SECTION 1.2 BUILDING STANDARDS COMMISSION |
44 | SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS SECTION 1.5 SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE |
45 | SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS |
46 | SECTION 1.8.3 LOCAL ENFORCING AGENCY |
47 | SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT |
48 | SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION |
49 | SECTION 1.8.8 APPEALS BOARD SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES |
50 | SECTION 1.8.10 OTHER BUILDING REGULATIONS SECTION 1.9 DIVISION OF THE STATE ARCHITECT |
52 | SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT |
54 | SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL |
58 | SECTION 1.12 STATE LIBRARIAN |
59 | SECTION 1.13 DEPARTMENT OF WATER RESOURCES SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION |
60 | DIVISION II SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL |
61 | SECTION 102 APPLICABILITY PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY |
62 | SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
63 | SECTION 105 PERMITS |
65 | SECTION 106 FLOOR AND ROOF DESIGN LOADS SECTION 107 SUBMITTAL DOCUMENTS |
67 | SECTION 108 TEMPORARY STRUCTURES AND USES SECTION 109 FEES SECTION 110 INSPECTIONS |
68 | SECTION 111 CERTIFICATE OF OCCUPANCY |
69 | SECTION 112 SERVICE UTILITIES SECTION 113 BOARD OF APPEALS SECTION 114 VIOLATIONS |
70 | SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT |
72 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS |
73 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
74 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
75 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
76 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
77 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued |
78 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued |
79 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
80 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
81 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
82 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
130 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – OCCUPANCY CLASSIFICATION AND USE |
132 | CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE SECTION 301 SCOPE SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION SECTION 303 ASSEMBLY GROUP A |
133 | SECTION 304 BUSINESS GROUP B |
134 | SECTION 305 EDUCATIONAL GROUP E SECTION 306 FACTORY GROUP F |
135 | SECTION 307 HIGH-HAZARD GROUP H TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
136 | TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
137 | [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD |
138 | SECTION 308 INSTITUTIONAL GROUP I |
140 | SECTION 309 MERCANTILE GROUP M SECTION 310 RESIDENTIAL GROUP R |
141 | SECTION 311 STORAGE GROUP S |
142 | SECTION 312 UTILITY AND MISCELLANEOUS GROUP U SECTION 313 LABORATORIES GROUP L [SFM] SECTION 314 ORGANIZED CAMPS GROUP C [SFM] |
144 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY |
145 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued |
146 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued |
147 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued |
148 | CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE SECTION 401 SCOPE SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS |
151 | EQUATION 4-1 |
152 | SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS |
153 | TABLE 403.2.4 MINIMUM BOND STRENGTH |
155 | SECTION 404 ATRIUMS |
156 | SECTION 405 UNDERGROUND BUILDINGS |
157 | SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES |
160 | TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT |
161 | SECTION 407 GROUP I-2 |
166 | SECTION 408 GROUP I-3 |
172 | SECTION 409 MOTION PICTURE PROJECTION ROOMS SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS |
174 | SECTION 411 SPECIAL AMUSEMENT BUILDINGS |
175 | SECTION 412 AIRCRAFT-RELATED OCCUPANCIES TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS |
177 | [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS |
178 | TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE |
179 | SECTION 413 COMBUSTIBLE STORAGE SECTION 414 HAZARDOUS MATERIALS |
180 | [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS |
181 | [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA |
182 | [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS |
183 | SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5 |
184 | [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED |
187 | [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5 |
192 | SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES SECTION 417 DRYING ROOMS SECTION 418 ORGANIC COATINGS |
193 | SECTION 419 LIVE/WORK UNITS SECTION 420 GROUPS R-1, R-2, R-2.1, R-2.2, R-3, R-3.1, AND R-4 |
195 | SECTION 421 HYDROGEN FUEL GAS ROOMS SECTION 422 AMBULATORY CARE FACIILITIES |
196 | SECTION 423 STORM SHELTERS SECTION 424 CHILDREN’S PLAY STRUCTURES |
197 | SECTION 425 HYPERBARIC FACILITIES SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE SECTION 427 MEDICAL GAS SYSTEMS |
198 | SECTION 435 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM] |
201 | SECTION 436 GROUP I-4 [SFM] |
202 | SECTION 437 RESERVED SECTION 438 RESERVED SECTION 439 ROAD TUNNELS, BRIDGES, AND OTHER LIMITED-ACCESS HIGHWAYS [SFM] SECTION 440 HORSE RACING STABLES [SFM] SECTION 441 PET KENNELS AND PET BOARDING FACILITIES [SFM] SECTION 442 COMBUSTION ENGINES AND GAS TURBINES [SFM] SECTION 443 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS [SFM] |
203 | SECTION 444 EXPLOSIVES [SFM] SECTION 445 RESERVED SECTION 446 WINERY CAVES [SFM] |
204 | SECTION 447 RESERVED SECTION 448 RESERVED SECTION 449 PUBLIC LIBRARIES [SL AND SFM] SECTION 450 GROUP C [SFM] |
207 | SECTION 451 RESERVED SECTION 452 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE |
208 | SECTION 453 GROUP L [SFM] |
210 | TABLE 453.7.2.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE |
211 | SECTION 454 RESERVED SECTION 455 LARGE FAMILY DAY-CARE HOMES [SFM] |
212 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS |
214 | CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 501 GENERAL SECTION 502 BUILDING ADDRESS SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS |
215 | FIGURE 5-1 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES |
216 | TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE |
217 | SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS |
218 | TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE |
219 | TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE |
220 | SECTION 506 BUILDING AREA EQUATION 5-1 EQUATION 5-2 |
221 | TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET |
222 | TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET |
223 | TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET |
224 | EQUATION 5-3 EQUATION 5-4 EQUATION 5-5 SECTION 507 UNLIMITED AREA BUILDINGS |
226 | SECTION 508 MIXED USE AND OCCUPANCY |
228 | TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) SECTION 509 INCIDENTAL USES |
229 | [F] TABLE 509 INCIDENTAL USES SECTION 510 SPECIAL PROVISIONS |
232 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION |
234 | CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) SECTION 602 CONSTRUCTION CLASSIFICATION |
235 | TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE |
236 | SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION |
238 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES |
240 | CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 701 GENERAL SECTION 702 MULTIPLE USE FIRE ASSEMBLIES SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS |
241 | SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS |
243 | SECTION 705 EXTERIOR WALLS TABLE 705.2 MINIMUM DISTANCE OF PROJECTION |
244 | EQUATION 7-1 |
245 | FIGURE 705.7 EQUIVALENT OPENING FACTOR EQUATION 7-2 |
246 | TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION |
248 | SECTION 706 FIRE WALLS TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS |
250 | SECTION 707 FIRE BARRIERS TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS |
251 | SECTION 708 FIRE PARTITIONS |
253 | SECTION 709 SMOKE BARRIERS SECTION 710 SMOKE PARTITIONS |
254 | SECTION 711 FLOOR AND ROOF ASSEMBLIES |
255 | SECTION 712 VERTICAL OPENINGS |
256 | SECTION 713 SHAFT ENCLOSURES |
258 | SECTION 714 PENETRATIONS |
260 | SECTION 715 FIRE-RESISTANT JOINT SYSTEMS |
261 | SECTION 716 OPENING PROTECTIVES |
262 | TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES |
263 | TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
264 | TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS |
268 | SECTION 717 DUCTS AND AIR TRANSFER OPENINGS |
269 | TABLE 717.3.2.1 FIRE DAMPER RATING |
274 | SECTION 718 CONCEALED SPACES |
275 | SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER |
276 | SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS SECTION 721 PRESCRIPTIVE FIRE RESISTANCE |
278 | SECTION 722 CALCULATED FIRE RESISTANCE TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING EQUATION 7-3 |
279 | TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
280 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
281 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
282 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS |
283 | TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
284 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
285 | TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
286 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
287 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
288 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
289 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
290 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
291 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
292 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
293 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
294 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
295 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
296 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
297 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
298 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
299 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
300 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
301 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
302 | EQUATION 7-4 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION |
303 | TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches) |
304 | FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS TABLE 722.2.1.2 (1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4 TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59 |
305 | FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS EQUATION 7-5 FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS |
306 | FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES |
307 | TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE) TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb |
308 | TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches) |
309 | EQUATION 7-6 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS |
310 | EQUATION 7-7 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches) TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches) EQUATION 7-8 |
311 | TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS TABLE 722.4.1(3) VALUES OF Rn 0.59 TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a TABLE 722.4.1(5) REINFORCED MASONRY LINTELS TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS |
312 | EQUATION 7-9 EQUATION 7-10 EQUATION 7-11 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS |
313 | FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM |
314 | FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS |
315 | FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS EQUATION 7-12 EQUATION 7-13 |
316 | EQUATION 7-14 EQUATION 7-15 EQUATION 7-16 |
317 | FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS EQUATION 7-17 |
319 | TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS TABLE 722.5.1(2) PROPERTIES OF CONCRETE |
320 | TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
321 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
322 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
323 | TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
324 | TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
325 | TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS |
326 | TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETE [FIGURE 722.5.1(6)(c)] TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETE [FIGURE 722.5.1(6)(c)] |
327 | TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERS [FIGURE 722.5.1(6)(a)] TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] |
328 | TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS |
329 | TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION |
330 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE SECTION 701A SCOPE, PURPOSE AND APPLICATION |
331 | SECTION 702A DEFINITIONS |
332 | SECTION 703A STANDARDS OF QUALITY |
333 | SECTION 704A IGNITION-RESISTANT CONSTRUCTION SECTION 705A ROOFING SECTION 706A VENTS |
334 | SECTION 707A EXTERIOR COVERING |
336 | SECTION 708A EXTERIOR WINDOWS, SKYLIGHTS AND DOORS |
337 | SECTION 709A DECKING |
338 | SECTION 710A ACCESSORY STRUCTURES |
340 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES |
342 | CHAPTER 8 INTERIOR FINISHES SECTION 801 SCOPE SECTION 802 GENERAL SECTION 803 WALL AND CEILING FINISHES |
344 | TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY |
345 | SECTION 804 INTERIOR FLOOR FINISH |
346 | SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION SECTION 806 DECORATIVE MATERIALS AND TRIM |
347 | SECTION 807 INSULATION SECTION 808 ACOUSTICAL CEILING SYSTEMS |
348 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS |
349 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued |
350 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued |
351 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued |
352 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued |
353 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued |
354 | CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS SECTION 901 GENERAL |
355 | SECTION 902 FIRE PUMP AND RISER ROOM SIZE SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
357 | [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
359 | [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS |
364 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
366 | SECTION 905 STANDPIPE SYSTEMS |
369 | SECTION 906 PORTABLE FIRE EXTINGUISHERS |
370 | [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE [F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS [F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa |
371 | SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
385 | [F] TABLE 907.5.2.3.2 VISIBLE ALARMS |
388 | SECTION 908 EMERGENCY ALARM SYSTEMS SECTION 909 SMOKE CONTROL SYSTEMS |
390 | EQUATION 9-1 EQUATION 9-2 |
396 | SECTION 910 SMOKE AND HEAT REMOVAL |
397 | EQUATION 9-3 EQUATION 9-4 SECTION 911 FIRE COMMAND CENTER |
399 | SECTION 912 FIRE DEPARTMENT CONNECTIONS SECTION 913 FIRE PUMPS |
400 | SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES SECTION 915 CARBON MONOXIDE DETECTION |
402 | SECTION 916 GAS DETECTION SYSTEMS |
403 | SECTION 917 MASS NOTIFICATION SYSTEMS SECTION 918 EMERGENCY RESPONDER RADIO COVERAGE |
404 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS |
405 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
406 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
407 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
408 | CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION [F] SECTION 1002 MAINTENANCE AND PLANS SECTION 1003 GENERAL MEANS OF EGRESS |
410 | SECTION 1004 OCCUPANT LOAD TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT |
411 | SECTION 1005 MEANS OF EGRESS SIZING |
412 | SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS |
413 | TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY |
415 | TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 AND R-3 OCCUPANCIES SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION |
416 | TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES SECTION 1008 MEANS OF EGRESS ILLUMINATION |
417 | SECTION 1009 ACCESSIBLE MEANS OF EGRESS |
420 | SECTION 1010 DOORS, GATES AND TURNSTILES |
422 | TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS TABLE 1010.1.4.1(2)MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS |
430 | SECTION 1011 STAIRWAYS |
434 | SECTION 1012 RAMPS |
435 | SECTION 1013 EXIT SIGNS |
436 | SECTION 1014 HANDRAILS |
438 | SECTION 1015 GUARDS |
439 | SECTION 1016 EXIT ACCESS |
440 | SECTION 1017 EXIT ACCESS TRAVEL DISTANCE TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa |
441 | SECTION 1018 AISLES SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS |
442 | SECTION 1020 CORRIDORS TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING |
443 | TABLE 1020.2 MINIMUM CORRIDOR WIDTH |
444 | SECTION 1021 EGRESS BALCONIES SECTION 1022 EXITS SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS |
446 | SECTION 1024 EXIT PASSAGEWAYS |
447 | SECTION 1025 LUMINOUS EGRESS PATH MARKINGS |
448 | SECTION 1026 HORIZONTAL EXITS |
449 | SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS |
450 | SECTION 1028 EXIT DISCHARGE |
451 | SECTION 1029 ASSEMBLY |
452 | TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY |
456 | TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS |
458 | SECTION 1030 EMERGENCY ESCAPE AND RESCUE |
460 | CHAPTER 11 RESERVED |
462 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY |
464 | CHAPTER 11A HOUSING ACCESSIBILITY DIVISION I – APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS SECTION 1101A APPLICATION SECTION 1102A BUILDING ACCESSIBILITY |
465 | SECTION 1103A DESIGN AND CONSTRUCTION SECTION 1104A COVERED MULTIFAMILY DWELLINGS |
466 | SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES SECTION 1106A SITE AND BUILDING CHARACTERISTICS SECTION 1107A DEFINITIONS |
467 | DIVISION II – EXTERIOR FACILITIES SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL SECTION 1109A PARKING FACILITIES |
469 | SECTION 1110A EXTERIOR ACCESSIBLE ROUTES |
470 | SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES SECTION 1113A WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES |
471 | SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES |
472 | SECTION 1115A EXTERIOR STAIRWAYS |
473 | SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES |
474 | DIVISION III – BUILDING FEATURES SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY SECTION 1118A EGRESS AND AREAS OF REFUGE SECTION 1119A INTERIOR ACCESSIBLE ROUTES |
475 | SECTION 1120A RESERVED SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES |
476 | SECTION 1123A INTERIOR STAIRWAYS |
477 | SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS |
478 | TABLE 1124A.3.2 ELEVATOR CAR DIMENSIONS |
479 | SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES |
480 | SECTION 1126A DOORS, GATES AND WINDOWS |
482 | SECTION 1127A COMMON USE FACILITIES |
489 | DIVISION IV – DWELLING UNIT FEATURES SECTION 1128A COVERED DWELLING UNITS SECTION 1129A RESERVED SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1132A DOORS |
490 | SECTION 1133A KITCHENS |
492 | SECTION 1134A BATHING AND TOILET FACILITIES |
495 | SECTION 1135A LAUNDRY ROOMS SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS |
496 | DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS SECTION 1137A OTHER FEATURES AND FACILITIES SECTION 1138A SPACE ALLOWANCES AND REACH RANGES |
498 | SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS |
499 | SECTION 1140A ACCESSIBLE TELEPHONES SECTION 1141A ACCESSIBLE SWIMMING POOLS |
500 | SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS SECTION 1143A SIGNAGE |
501 | TABLE 1143A.5 VISUAL CHARACTER HEIGHT |
502 | TABLE 1143A.7.1 BRAILLE DIMENSIONS SECTION 1144A RESERVED SECTION 1145A RESERVED SECTION 1146A RESERVED SECTION 1147A RESERVED SECTION 1148A RESERVED SECTION 1149A RESERVED |
503 | DIVISION VI – SITE IMPRACTICALITY TESTS SECTION 1150A SITE IMPRACTICALITY TESTS TEST NO. 1—INDIVIDUAL BUILDING TEST TEST NO. 2—SITE ANALYSIS TEST |
504 | TEST NO. 3—UNUSUAL CHARACTERISTICS TEST |
505 | DIVISION VII – FIGURES FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL |
506 | FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION |
507 | FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS |
508 | FIGURE 11A-1D WHEELCHAIR TURNING SPACE FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH |
509 | FIGURE 11A-1F CHANGE IN LEVEL |
510 | FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS |
511 | FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES |
512 | FIGURE 11A-1I FORWARD REACH |
513 | FIGURE 11A-1J SIDE REACH |
514 | FIGURE 11A-1K MINIMUM CLEARANCES FOR SEATING AND TABLE |
515 | FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE |
516 | FIGURE 11A-2A DOUBLE PARKING STALLS FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS |
517 | FIGURE 11A-2C DIAGONAL PARKING STALLS |
518 | FIGURE 11A-3A CURB DETAILS |
519 | FIGURE 11A-3B CURB DETAIL |
520 | FIGURE 11A-3C CURB DETAIL |
521 | FIGURE 11A-3D CURB DETAIL FIGURE 11A-3E CURB DETAIL |
522 | FIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60″ WIDE FIGURE 11A-3G CURB DETAIL |
523 | FIGURE 11A-3H CURB DETAIL FIGURE 11A-3I CURB DETAIL |
524 | FIGURE 11A-3J CURB DETAIL FIGURE 11A-3K CURB DETAIL |
525 | FIGURE 11A-3L CURB SECTIONS |
526 | FIGURE 11A-5A RAMPS AND SIDEWALKS |
527 | FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS |
528 | FIGURE 11A-6B HANDRAILS |
529 | FIGURE 11A-6C RAMP DIMENSIONS |
530 | FIGURE 11A-6D RAMP LANDING AND DOORWAY |
531 | FIGURE 11A-6E STAIR HANDRAILS |
532 | FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS |
533 | FIGURE 11A-7B ELEVATOR CONTROL PANEL |
534 | FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES FIGURE 11A-7D GRAPH OF TIMING EQUATION |
535 | FIGURE 11A-8A MANEUVERING CLEARANCE AT SWINGING DOORS |
536 | FIGURE 11A-8B MANEUVERING CLEARANCE AT DOORWAYS, SLIDING DOORS, AND FOLDING DOORS |
537 | FIGURE 11A-8C MANEUVERING CLEARANCES AT RECESSED DOORS |
538 | FIGURE 11A-8G VESTIBULE |
539 | FIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY) |
540 | FIGURE 11A-8I THRESHOLDS FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR |
541 | FIGURE 11A-9A TOILET FACILITIES |
542 | FIGURE 11A-9B WATER CLOSETS |
543 | FIGURE 11A-9C GRAB BARS |
544 | FIGURE 11A-9D KNEE AND TOE SPACE |
545 | FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS |
546 | FIGURE 11A-9F GRAB BARS AT BATHTUBS |
547 | FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS |
548 | FIGURE 11A-9H STANDARD ROLL-IN SHOWER |
549 | FIGURE 1A-9I SHOWER SEATS AND GRAB BARS |
550 | FIGURE 11A-9J OPEN SHOWER |
551 | FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER |
552 | FIGURE 11A-9L SHOWER WITH WATER CLOSET FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET |
553 | FIGURE 11A-10A KITCHEN SPECIFICATIONS |
554 | FIGURE 11A-11A DRINKING FOUNTAINS |
555 | FIGURE 11A-11B TELEPHONES |
556 | FIGURE 11A-11C INTERNATIONAL TTY SYMBOL FIGURE 11A-11D VOLUME CONTROL TELEPHONES FIGURE 11A-11E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS |
558 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,COMMERCIAL BUILDINGS AND PUBLIC HOUSING |
560 | CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING DIVISION 1: APPLICATION AND ADMINISTRATION 11B-101 PURPOSE 11B-102 DIMENSIONS FOR ADULTS AND CHILDREN 11B-103 EQUIVALENT FACILITATION 11B-104 CONVENTIONS FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES 11B-105 REFERENCED STANDARDS 11B-106 DEFINITIONS |
562 | 11B-107 SPECIAL CONDITIONS APPEALS ACTION 11B-108 MAINTENANCE OF ACCESSIBLE FEATURES |
563 | DIVISION 2: SCOPING REQUIREMENTS 11B-201 APPLICATION 11B-202 EXISTING BUILDINGS AND FACILITIES |
565 | 11B-203 GENERAL EXCEPTIONS |
566 | 11B-204 PROTRUDING OBJECTS 11B-205 OPERABLE PARTS 11B-206 ACCESSIBLE ROUTES |
571 | 11B-207 ACCESSIBLE MEANS OF EGRESS 11B-208 PARKING SPACES TABLE 11B-208.2 PARKING SPACES |
572 | 11B-209 PASSENGER DROP-OFF AND LOADING ZONES AND BUS STOPS 11B-210 STAIRWAYS |
573 | 11B-211 DRINKING FOUNTAINS 11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS 11B-213 TOILET FACILITIES AND BATHING FACILITIES |
574 | 11B-214 WASHING MACHINES AND CLOTHES DRYERS 11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS 11B-216 SIGNS |
576 | 11B-217 TELEPHONES TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES |
577 | 11B-218 TRANSPORTATION FACILITIES 11B-219 ASSISTIVE LISTENING SYSTEMS |
578 | 11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINTOF SALE DEVICES 11B-221 ASSEMBLY AREAS TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS |
580 | 11B-222 DRESSING, FITTING, AND LOCKER ROOMS 11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES |
581 | 11B-224 TRANSIENT LODGING GUEST ROOMS, HOUSING AT A PLACE OF EDUCATION AND SOCIAL SERVICE CENTER ESTABLISHMENTS TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES |
582 | TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES 11B-225 STORAGE |
583 | TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES 11B-226 DINING SURFACES AND WORK SURFACES 11B-227 SALES AND SERVICE TABLE 11B-227.2 CHECK-OUT AISLES |
584 | 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, FUEL DISPENSERS, AND ELECTRIC VEHICLE CHARGING STATIONS 11B-229 WINDOWS 11B-230 TWO-WAY COMMUNICATION SYSTEMS 11B-231 JUDICIAL FACILITIES |
585 | TABLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC USE AND COMMON USE 11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES |
586 | 11B-233 PUBLIC HOUSING FACILITIES |
587 | 11B-234 AMUSEMENT RIDES |
588 | 11B-235 RECREATIONAL BOATING FACILITIES TABLE 11B-235.2 BOAT SLIPS 11B-236 EXERCISE MACHINES AND EQUIPMENT 11B-237 FISHING PIERS AND PLATFORMS 11B-238 GOLF FACILITIES 11B-239 MINIATURE GOLF FACILITIES |
589 | 11B-240 PLAY AREAS TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES 11B-241 SAUNAS AND STEAM ROOMS |
590 | 11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS 11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS 11B-244 RELIGIOUS FACILITIES 11B-245 PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RESIDENCES 11B-246 OUTDOOR DEVELOPED AREAS |
591 | 11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE 11B-248 COMMON USE AREAS AND EMPLOYEE WORK AREAS 11B-249 ADULT CHANGING FACILITIES |
592 | DIVISION 3: BUILDING BLOCKS 11B-301 GENERAL 11B-302 FLOOR OR GROUND SURFACES FIGURE 11B-302.2 CARPET PILE HEIGHT FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES 11B-303 CHANGES IN LEVEL FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL 11B-304 TURNING SPACE |
593 | FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE 11B-305 CLEAR FLOOR OR GROUND SPACE FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH |
594 | FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH 11B-306 KNEE AND TOE CLEARANCE FIGURE 11B-306.2 TOE CLEARANCE FIGURE 11B-306.3 KNEE CLEARANCE |
595 | 11B-307 PROTRUDING OBJECTS FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS |
596 | FIGURE 11B-307.4 VERTICAL CLEARANCE FIGURE 11B-307.4.1 GUY BRACES 11B-308 REACH RANGES FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH |
597 | FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH TABLE 11B-308.4 SUGGESTED DIMENSIONS FOR CHILDREN’S USE 11B-309 OPERABLE PARTS |
598 | DIVISION 4: ACCESSIBLE ROUTES 11B-401 GENERAL 11B-402 ACCESSIBLE ROUTES 11B-403 WALKING SURFACES FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE |
599 | FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN 11B-404 DOORS, DOORWAYS, AND GATES |
600 | FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
601 | FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
602 | FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
603 | TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS |
604 | FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES |
606 | 11B-405 RAMPS |
607 | FIGURE 11B-405.7 RAMP LANDINGS FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION 11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS |
608 | FIGURE 11B-406.2.2 SIDES OF CURB RAMPS FIGURE 11B-406.3.2 PARALLEL CURB RAMPS FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS |
609 | FIGURE 11B-406.5.8 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS FIGURE 11B-406.6 ISLANDS IN CROSSINGS 11B-407 ELEVATORS |
610 | FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS |
611 | FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS |
612 | FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS |
613 | TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION |
614 | 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS |
615 | FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS 11B-409 PRIVATE RESIDENCE ELEVATORS |
616 | FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL 11B-410 PLATFORM LIFTS FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES 11B-411 DESTINATION-ORIENTED ELEVATORS |
617 | FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION |
620 | FIGURE 11B-411.2.3 FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES |
622 | DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS 11B-501 GENERAL 11B-502 PARKING SPACES FIGURE 11B-502.2 VEHICLE PARKING SPACES |
623 | FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE |
624 | FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION |
625 | 11B-503 PASSENGER DROP-OFF AND LOADING ZONES FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE |
626 | 11B-504 STAIRWAYS FIGURE 11B-504.5 STAIR NOSINGS 11B-505 HANDRAILS |
627 | FIGURE 11B-505.4 HANDRAIL HEIGHT FIGURE 11B-505.5 HANDRAIL CLEARANCE FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION |
628 | FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS FIGURE 11B-505.10.2TOP HANDRAIL FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS |
629 | DIVISION 6: PLUMBING ELEMENTS AND FACILITIES 11B-601 GENERAL 11B-602 DRINKING FOUNTAINS FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION 11B-603 TOILET AND BATHING ROOMS |
630 | 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS FIGURE 11B-604.2 WATER CLOSET LOCATION FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS |
631 | FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS FIGURE 11B-604.7.1 DISPENSER OUTLET LOCATION FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS FIGURE 11B-604.7.2 DISPOSAL UNIT LOCATION |
632 | FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR |
633 | FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS |
634 | FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE FIGURE 11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT |
635 | TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE 11B-605 URINALS FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS 11B-606 LAVATORIES AND SINKS |
636 | 11B-607 BATHTUBS FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS |
637 | FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS |
638 | FIGURE 11B-607.5 BATHTUB CONTROL LOCATION 11B-608 SHOWER COMPARTMENTS FIGURE 11B-608.2.1 TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE |
639 | FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE FIGURE 11B-608.3.1 GRAB BARS FOR TRANSFER TYPE SHOWERS FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS |
640 | FIGURE 11B-608.5.1 TRANSFER TYPE SHOWER COMPARTMENT CONTROL LOCATION FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION |
641 | 11B-609 GRAB BARS FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION FIGURE 11B-609.3 SPACING OF GRAB BARS 11B-610 SEATS |
642 | FIGURE 11B-610.2 BATHTUB SEATS FIGURE 11B-610.3 EXTENT OF SEAT FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT 11B-611 WASHING MACHINES AND CLOTHES DRYERS |
643 | FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING 11B-612 SAUNAS AND STEAM ROOMS |
644 | DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES 11B-701 GENERAL 11B-702 FIRE ALARM SYSTEMS 11B-703 SIGNS FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS |
645 | TABLE 11B-703.3.1 BRAILLE DIMENSIONS FIGURE 11B-703.3.1 BRAILLE MEASUREMENT FIGURE 11B-703.3.2 POSITION OF BRAILLE FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND |
646 | FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT |
647 | FIGURE 11B-703.6.1 PICTOGRAM FIELD FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE |
648 | FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS FIGURE 11B-703.7.2.6.4 EDGES AND VERTICES ON GEOMETRIC SYMBOLS |
649 | TABLE 11B-703.8.4 LOW RESOLUTION VMS CHARACTER HEIGHT FIGURE 11B-703.8.5 LOW RESOLUTION VMS CHARACTERS TABLE 11B-703.8.5 PIXEL COUNT FOR LOW RESOLUTION VMS |
650 | 11B-704 TELEPHONES FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE |
651 | FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES |
652 | FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE 11B-706 ASSISTIVE LISTENING SYSTEMS 11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT OF SALE DEVICES |
653 | FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT |
654 | 11B-708 TWO-WAY COMMUNICATION SYSTEMS |
655 | DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS 11B-801 GENERAL 11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS |
656 | FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS 11B-803 DRESSING, FITTING, AND LOCKER ROOMS 11B-804 KITCHENS, KITCHENETTES, AND WET BARS |
657 | FIGURE 11B-804.2.1 PASS THROUGH KITCHENS FIGURE 11B-804.2.2 U-SHAPED KITCHENS |
658 | 11B-805 MEDICAL CARE AND LONG-TERM CARE FACILITIES |
659 | 11B-806 TRANSIENT LODGING GUEST ROOMS 11B-807 HOLDING CELLS AND HOUSING CELLS |
660 | 11B-808 COURTROOMS 11B-809 RESIDENTIAL DWELLING UNITS |
661 | 11B-810 TRANSPORTATION FACILITIES FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS FIGURE 11B-810.3 BUS SHELTERS |
662 | FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS 11B-811 STORAGE 11B-812 ELECTRIC VEHICLE CHARGING STATIONS |
664 | FIGURE 11B-812.9 SURFACE MARKING 11B-813 ADULT CHANGING FACILITIES |
665 | FIGURE 11B-813.2.1.2 CLEARANCE AROUND ADULT CHANGING TABLE |
666 | DIVISION 9: BUILT-IN ELEMENTS 11B-901 GENERAL 11B-902 DINING SURFACES AND WORK SURFACES 11B-903 BENCHES FIGURE 11B-903.4 BENCH BACK SUPPORT 11B-904 CHECK OUT AISLES AND SALES AND SERVICE COUNTERS |
667 | FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS |
668 | DIVISION 10: RECREATION FACILITIES 11B-1001 GENERAL 11B-1002 AMUSEMENT RIDES FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES |
669 | 11B-1003 RECREATIONAL BOATING FACILITIES |
670 | FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS |
671 | FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS 11B-1004 EXERCISE MACHINES AND EQUIPMENT |
672 | 11B-1005 FISHING PIERS AND PLATFORMS FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS 11B-1006 GOLF FACILITIES |
673 | 11B-1007 MINIATURE GOLF FACILITIES FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA 11B-1008 PLAY AREAS |
674 | FIGURE 11B-1008.3.1 TRANSFER PLATFORMS |
675 | FIGURE 11B-1008.3.2 TRANSFER STEPS 11B-1009 SWIMMING POOLS, WADING POOLS. AND SPAS FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION |
676 | FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH |
677 | FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT |
678 | FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM |
679 | FIGURE 11B-1009.5.4 TRANSFER STEPS FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS FIGURE 11B-1009.5.7 GRAB BARS 11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS |
680 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT |
682 | CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL SECTION 1202 VENTILATION |
683 | TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL |
685 | SECTION 1203 TEMPERATURE CONTROL SECTION 1204 LIGHTING |
686 | SECTION 1205 YARDS OR COURTS SECTION 1206 SOUND TRANSMISSION SECTION 1207 INTERIOR SPACE DIMENSIONS |
687 | SECTION 1208 ACCESS TO UNOCCUPIED SPACES SECTION 1209 TOILET AND BATHROOM REQUIREMENTS |
688 | SECTION 1210 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS SECTION 1211 [HCD 1] POLLUTANT CONTROL |
689 | SECTION 1212 RESERVED SECTION 1213 RESERVED SECTION 1214 RESERVED SECTION 1215 RESERVED SECTION 1216 RESERVED SECTION 1217 RESERVED SECTION 1218 RESERVED SECTION 1219 RESERVED SECTION 1220 RESERVED SECTION 1221 RESERVED SECTION 1222 RESERVED SECTION 1223 RESERVED SECTION 1224 [OSHPD 1 & OSHPD 1R] HOSPITALS |
695 | TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR SYSTEMS1 |
696 | TABLE 1224.4.6.5 [OSHPD 1, 1R, 2, 3, 4 & 5] LOCATION OF NURSE CALL DEVICES • = Required |
698 | TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS |
701 | TABLE 1224.4.19 SOUND TRANSMISSION LIMITATIONS IN HOSPITALS |
736 | SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES |
745 | SECTION 1226 [OSHPD 3] CLINICS |
757 | SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS |
762 | SECTION 1228 [OSHPD 5] ACUTE PSYCHIATRIC HOSPITALS |
767 | SECTION 1229 RESERVED SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES |
769 | TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES |
772 | SECTION 1231 [BSCC] LOCAL DETENTION |
775 | TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES |
777 | SECTION 1232 RESERVED SECTION 1233 RESERVED SECTION 1234 RESERVED SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS) |
778 | SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES |
779 | SECTION 1238 RESERVED SECTION 1239 RESERVED SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS |
780 | TABLE 1240.15.1 SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES |
781 | SECTION 1242 [AGR] RENDERERS SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS |
782 | SECTION 1244 RESERVED SECTION 1245 RESERVED SECTION 1246 RESERVED SECTION 1247 RESERVED SECTION 1247 RESERVED SECTION 1248 RESERVED SECTION 1249 RESERVED SECTION 1250 [CA] PHARMACIES SECTION 1251 [CA] VETERINARY FACILITIES |
783 | SECTION 1252 [CA] BARBER COLLEGES AND SHOPS SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS SECTION 1254 [CA] ACUPUNCTURE OFFICES |
784 | CHAPTER 13 ENERGY EFFICIENCY Refer to California Energy Code, Title 24, Part 6 |
786 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS |
788 | CHAPTER 14 EXTERIOR WALLS SECTION 1401 GENERAL SECTION 1402 PERFORMANCE REQUIREMENTS |
789 | SECTION 1403 MATERIALS SECTION 1404 INSTALLATION OF WALL COVERINGS |
790 | TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS |
791 | TABLE 1404.3.2 CLASS III VAPOR RETARDERS |
795 | SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS |
796 | TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS SECTION 1406 METAL COMPOSITE MATERIALS (MCM) |
797 | TABLE 1406.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS |
798 | SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL) |
799 | SECTION 1409 PLASTIC COMPOSITE DECKING |
800 | SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER |
802 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES |
804 | CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL SECTION 1502 ROOF DRAINAGE SECTION 1503 WEATHER PROTECTION SECTION 1504 PERFORMANCE REQUIREMENTS |
805 | TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D316 OR D71581 |
806 | TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION SECTION 1505 FIRE CLASSIFICATION TABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION |
807 | SECTION 1506 MATERIALS SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS |
808 | TABLE 1507.1.1(1) UNDERLAYMENT TYPES |
809 | TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION |
810 | TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT |
811 | TABLE 1507.2.8.2 VALLEY LINING MATERIAL |
812 | TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
813 | TABLE 1507.4.3(1) METAL ROOF COVERINGS TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE |
814 | TABLE 1507.7.6 SLATE SHINGLE HEADLAP |
815 | TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS |
816 | TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS |
817 | TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS |
818 | TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS |
819 | SECTION 1508 ROOF INSULATION [BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK |
820 | SECTION 1510 ROOFTOP STRUCTURES |
822 | SECTION 1511 REROOFING |
823 | SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES SECTION 1513 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS |
824 | INDEX |
866 | HISTORY NOTE APPENDIX |
868 | HELPFUL TOOLS FOR YOUR CALIFORNIA BUILDING CODE |
869 | ICC-ES DSA AND OSHPD EVALUATION SERVICE |