Shopping Cart

No products in the cart.

CA BuildingCode vol1 2013

$155.46

California Building Code, Title 24 Part 2, Volume 1 (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2013 823
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies). This 2-volume set is a fully integrated code based on the 2012 International Building Code®. The CBC includes: Title 24, Part 8 California Historical Building Code (CHBC): contains regulations of the State Historical Building Safety Board. Provisions contained in the CHBC provide for the preservation, restoration, rehabilitation, relocation, or reconstruction of buildings or structures designated as qualified historical buildings or properties. The CHBC contains alternative solutions for the preservation of qualified historical buildings or properties, to provide access for persons with disabilities, to provide a cost-effective approach to preservation, and to provide for the reasonable safety of the occupants or users. Title 24, Part 10 California Building Standards Commission (CBSC): adopts certain provisions of the International Existing Building Code, Appendix Chapter A1, Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings.

PDF Catalog

PDF Pages PDF Title
1 2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2
2 2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 BASED ON THE 2012 INTERNATIONAL BUILDING CODE® TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
5 CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
6 MARGINAL MARKINGS
8 EFFECTIVE USE OF THE IBC/CBC
18 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
20 CALIFORNIA MATRIX ADOPTION TABLES
22 TABLE OF CONTENTS
36 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – ADMINISTRATION
37 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – ADMINISTRATION—continued
38 CHAPTER 1 SCOPE AND ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
40 SECTION 1.2 BUILDING STANDARDS COMMISSION
41 SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS
42 SECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
43 SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
44 SECTION 1.8.3 LOCAL ENFORCING AGENCY
SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
45 SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
46 SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
SECTION 1.8.8 APPEALS BOARD
47 SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
48 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
50 SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT
52 SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
56 SECTION 1.12 STATE LIBRARIAN
SECTION 1.13 RESERVED
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION
58 DIVISION II SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
59 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
61 SECTION 105 PERMITS
63 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
64 SECTION 108 TEMPORARY STRUCTURES AND USES
65 SECTION 109 FEES
SECTION 110 INSPECTIONS
66 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
67 SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
70 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
71 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
72 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
73 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
74 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
75 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
76 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
77 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
78 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
79 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
80 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
124 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION
125 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION—continued
126 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
127 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
128 SECTION 307 HIGH-HAZARD GROUP H
130 [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
131 [F] TABLE 307.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
132 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
133 SECTION 308 INSTITUTIONAL GROUP I
134 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
136 SECTION 311 STORAGE GROUP S
137 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM]
138 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY
139 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
140 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
141 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
142 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued
144 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
148 SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS
149 TABLE 403.2.4 MINIMUM BOND STRENGTH
151 SECTION 404 ATRIUMS
SECTION 405 UNDERGROUND BUILDINGS
153 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
154 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
157 SECTION 407 GROUP I-2
160 SECTION 408 GROUP I-3
165 SECTION 409 MOTION PICTURE PROJECTION ROOMS
166 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
168 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
170 [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
171 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
172 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
173 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd,e,f
174 [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
175 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa
177 [F] TABLE 415.5.2 DETACHED BUILDING REQUIRED
180 [F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
185 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
186 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
187 SECTION 420 GROUPS R-1, R-2, R-2.1, R-3, R3.1 and R-4
190 SECTION 421 HYDROGEN CUTOFF ROOMS
SECTION 422 AMBULATORY CARE FACILITIES
191 SECTION 423 STORM SHELTERS
SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM]
194 SECTION 426 GROUP I-4 [SFM]
195 SECTION 427 RESERVED
SECTION 428 RESERVED
SECTION 429 RESERVED
SECTION 430 HORSE RACING STABLES [SFM]
SECTION 431 PET KENNELS [SFM]
SECTION 432 COMBUSTION ENGINES AND GAS TURBINES [SFM]
196 SECTION 433 FIXED GUIDEWAY TRANSIT SYSTEMS [SFM]
199 SECTION 434 EXPLOSIVES [SFM]
202 SECTION 435 RESERVED
SECTION 436 WINERY CAVES [SFM]
203 SECTION 437 RESERVED
SECTION 438 RESERVED
SECTION 439 PUBLIC LIBRARIES [SL AND SFM]
204 SECTION 440 GROUP C [SFM]
206 SECTION 441 RESERVED
SECTION 442 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE
207 SECTION 443 GROUP L [SFM]
210 TABLE 443.7.3.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
SECTION 444 RESERVED
SECTION 445 LARGE FAMILY DAY-CARE HOMES [SFM]
212 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
214 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
215 TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREASa, b Building height limitations shown in feet above grade plane. Story limitations shown as stories above grade plane. Building area limitations shown in square feet, as determined by the definition of “Area, building,” per story
216 TABLE 503—continued ALLOWABLE BUILDING HEIGHTS AND AREASa, b
FIGURE 5-1
217 SECTION 504 BUILDING HEIGHT
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
218 SECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
EQUATION 5-2
EQUATION 5-3
220 SECTION 507 UNLIMITED AREA BUILDINGS
221 SECTION 508 MIXED USE AND OCCUPANCY
222 SECTION 509 INCIDENTAL USES
223 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 510 SPECIAL PROVISIONS
224 TABLE 509 INCIDENTAL USES
228 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
230 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
231 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e
TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES
232 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
234 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
236 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
237 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
239 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
240 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-1
241 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
242 EQUATION 7-2
243 SECTION 706 FIRE WALLS
244 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
245 SECTION 707 FIRE BARRIERS
246 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
247 SECTION 708 FIRE PARTITIONS
248 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
249 SECTION 711 HORIZONTAL ASSEMBLIES
250 SECTION 712 VERTICAL OPENINGS
251 SECTION 713 SHAFT ENCLOSURES
253 SECTION 714 PENETRATIONS
256 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
257 SECTION 716 OPENING PROTECTIVES
TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
259 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
260 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
262 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
263 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
TABLE 717.3.2.1 FIRE DAMPER RATING
268 SECTION 718 CONCEALED SPACES
270 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
271 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
272 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
273 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
274 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
275 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
276 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
277 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
278 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
279 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
280 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
281 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
282 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
283 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
284 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
285 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
286 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
287 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
288 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
289 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM
290 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
291 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
292 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
293 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
294 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
295 SECTION 722 CALCULATED FIRE RESISTANCE
296 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
297 TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-4
298 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
299 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
300 EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
301 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
302 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
303 TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
304 EQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
305 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
306 TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
307 TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
308 EQUATION 7-12
EQUATION 7-13
FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
309 FIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
EQUATION 7-14
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
310 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
311 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
312 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
313 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
314 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
315 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
316 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
317 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
318 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
319 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMALWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
320 EQUATION 7-15
EQUATION 7-16
321 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
322 EQUATION 7-18
TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
323 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
324 FIGURE 722.6.3(1) LOAD FIGURE
FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS
326 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
328 CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION 701A SCOPE, PURPOSE AND APPLICATION
329 SECTION 702A DEFINITIONS
SECTION 703A STANDARDS OF QUALITY
330 SECTION 704A IGNITION-RESISTANT CONSTRUCTION
331 SECTION 705A ROOFING
SECTION 706A VENTS
SECTION 707A EXTERIOR COVERING
333 SECTION 708A EXTERIOR WINDOWS AND DOORS
334 SECTION 709A DECKING
SECTION 710A ACCESSORY STRUCTURES
336 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
338 CHAPTER 8 INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
340 TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
341 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
342 SECTION 806 DECORATIVE MATERIALS AND TRIM
SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
344 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS
345 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
346 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
347 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
348 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
349 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
350 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued
352 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
353 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
355 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
357 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
361 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
363 SECTION 905 STANDPIPE SYSTEMS
[F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE
366 SECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
367 [F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
382 [F] TABLE 907.5.2.3.3 VISIBLE ALARMS
384 SECTION 908 EMERGENCY ALARM SYSTEMS
385 SECTION 909 SMOKE CONTROL SYSTEMS
387 EQUATION 9-1
EQUATION 9-2
EQUATION 9-3
394 SECTION 910 SMOKE AND HEAT REMOVAL
395 EQUATION 9-4
[F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
396 SECTION 911 FIRE COMMAND CENTER
397 SECTION 912 FIRE DEPARTMENT CONNECTIONS
398 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE
400 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
401 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
402 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
403 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
404 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS
406 SECTION 1004 OCCUPANT LOAD
407 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
SECTION 1005 MEANS OF EGRESS SIZING
408 SECTION 1006 MEANS OF EGRESS ILLUMINATION
409 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
412 SECTION 1008 DOORS, GATES AND TURNSTILES
413 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
419 SECTION 1009 STAIRWAYS
423 SECTION 1010 RAMPS
425 SECTION 1011 EXIT SIGNS
426 SECTION 1012 HANDRAILS
427 SECTION 1013 GUARDS
429 SECTION 1014 EXIT ACCESS
TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
430 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
431 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
432 SECTION 1017 AISLES
SECTION 1018 CORRIDORS
433 TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1018.2 MINIMUM CORRIDOR WIDTH
434 SECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS
435 TABLE 1021.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
436 TABLE 1021.2(1) (IFC [B] TABLE 1021.2(1)) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2, R-3 AND R-4 OCCUPANCIES
TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
437 SECTION 1023 EXIT PASSAGEWAYS
438 SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
439 SECTION 1025 HORIZONTAL EXITS
440 SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
441 SECTION 1027 EXIT DISCHARGE
442 SECTION 1028 ASSEMBLY
443 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
445 TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
447 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
450 CHAPTER 11 RESERVED
452 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY
454 CHAPTER 11A HOUSING ACCESSIBILITY
DIVISION I – APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY
455 SECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS
456 SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS
457 DIVISION II – EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES
459 SECTION 1110A EXTERIOR ROUTES OF TRAVEL
460 SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON AN ACCESSIBLE ROUTE
461 SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
462 SECTION 1115A EXTERIOR STAIRWAYS
463 SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES
464 DIVISION III – BUILDING FEATURES
SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY
SECTION 1118A EGRESS AND AREAS OF REFUGE
SECTION 1119A INTERIOR ROUTES OF TRAVEL
SECTION 1120A INTERIOR ACCESSIBLE ROUTES
465 SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
466 SECTION 1123A INTERIOR STAIRWAYS
467 SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
469 SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
SECTION 1126A DOORS
471 SECTION 1127A COMMON USE FACILITIES
479 DIVISION IV – DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS
481 SECTION 1133A KITCHENS
482 SECTION 1134A BATHING AND TOILET FACILITIES
485 SECTION 1135A LAUNDRY ROOMS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
486 DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS
SECTION 1137A OTHER FEATURES AND FACILITIES
SECTION 1138A SPACE ALLOWANCES AND REACH RANGES
488 SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS
489 SECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS
490 SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE
491 TABLE 1143A.5 VISUAL CHARACTER HEIGHT
492 TABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED
493 DIVISION VI – SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1—INDIVIDUAL BUILDING TEST
TEST NO. 2—SITE ANALYSIS TEST
494 TEST NO. 3—UNUSUAL CHARACTERISTICS TEST
495 DIVISION VII – FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL
496 FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION
497 FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS
498 FIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH
499 FIGURE 11A-1F CHANGE IN LEVEL
500 FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS
501 FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES
502 FIGURE 11A-1I FORWARD REACH
503 FIGURE 11A-1J SIDE REACH
504 FIGURE 11A-1K
505 FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE
506 FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS
507 FIGURE 11A-2C DIAGONAL PARKING STALLS
508 FIGURE 11A-3A CURB DETAILS
509 FIGURE 11A-3B CURB DETAIL
510 FIGURE 11A-3C CURB DETAIL
511 FIGURE 11A-3D CURB DETAIL
512 FIGURE 11A-3E CURB DETAIL
513 FIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60”³ WIDE
FIGURE 11A-3G CURB DETAIL
514 FIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL
515 FIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL
516 FIGURE 11A-3L CURB SECTIONS
517 FIGURE 11A-5A RAMPS AND SIDEWALKS
518 FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS
519 FIGURE 11A-6B STAIR HANDRAILS
520 FIGURE 11A-6C RAMP DIMENSIONS
521 FIGURE 11A-6D RAMP LANDING AND DOORWAY
522 FIGURE 11A-6D RAMP LANDING AND DOORWAY
523 FIGURE 11A-6E STAIR HANDRAILS
524 FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS
525 FIGURE 11A-7B ELEVATOR CONTROL PANEL
526 FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION
527 FIGURE 11A-8A FRONT APPROACHES—SWINGING DOORS
FIGURE 11A-8B HINGE SIDE APPROACHES—SWINGING DOORS
528 FIGURE 11A-8C LATCH SIDE APPROACH—SWINGING DOORS
FIGURE 11A-8D FRONT APPROACH—SLIDING DOORS AND FOLDING DOORS
FIGURE 11A-8E SLIDE SIDE APPROACH—SLIDING DOORS AND FOLDING DOORS
FIGURE 11A-8F LATCH SIDE APPROACH—SLIDING DOORS AND FOLDING DOORS
529 FIGURE 11A-8G VESTIBULE
530 FIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY)
531 FIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR
532 FIGURE 11A-9A TOILET FACILITIES
533 FIGURE 11A-9B WATER CLOSETS
534 FIGURE 11A-9C GRAB BARS
535 FIGURE 11A-9D KNEE AND TOE SPACE
536 FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS
537 FIGURE 11A-9F GRAB BARS AT BATHTUBS
538 FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS
539 FIGURE 11A-9H STANDARD ROLL-IN SHOWER
540 FIGURE 1A-9I SHOWER SEATS AND GRAB BARS
541 FIGURE 11A-9J OPEN SHOWER
542 FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER
543 FIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET
544 FIGURE 11A-10A KITCHEN SPECIFICATIONS
545 FIGURE 11A-11A DRINKING FOUNTAINS
546 FIGURE 11A-11B MOUNTING HEIGHTS AND CLEARANCES FOR TELEPHONES
547 FIGURE 11A-1E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
548 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLICLY FUNDED HOUSING
550 CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES
552 11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES
553 DIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES
555 11B-203 GENERAL EXCEPTIONS
556 11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
11B-206 ACCESSIBLE ROUTES
560 11B-207 ACCESSIBLE MEANS OF EGRESS
11B-208 PARKING SPACES
561 TABLE 11B-208.2 PARKING SPACES
562 11B-209 PASSENGER LOADING ZONES AND BUS STOPS
11B-210 STAIRWAYS
11B-211 DRINKING FOUNTAINS
563 11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS
11B-213 TOILET FACILITIES AND BATHING FACILITIES
564 11B-214 WASHING MACHINES AND CLOTHES DRYERS
11B-215 FIRE ALARM SYSTEMS
11B-216 SIGNS
566 11B-217 TELEPHONES
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES
567 11B-218 TRANSPORTATION FACILITIES
11B-219 ASSISTIVE LISTENING SYSTEMS
568 11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
11B-221 ASSEMBLY AREAS
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
570 11B-222 DRESSING, FITTING AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES
571 11B-224 TRANSIENT LODGING GUEST ROOMS
572 TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES
11B-225 STORAGE
573 TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES
11B-226 DINING SURFACES AND WORK SURFACES
11B-227 SALES AND SERVICE
TABLE 11B-227.2 CHECK-OUT AISLES
574 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES AND FUEL DISPENSERS
11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATION SYSTEMS
11B-231 JUDICIAL FACILITIES
11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES
575 11B-233 RESIDENTIAL FACILITIES
577 11B-234 AMUSEMENT RIDES
11B-235 RECREATIONAL BOATING FACILITIES
TABLE 11B-235.2 BOAT SLIPS
578 11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
11B-240 PLAY AREAS
579 TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
11B-244 RELIGIOUS FACILITIES
580 11B-245 COMMERCIAL FACILITIES LOCATED IN PRIVATE RESIDENCES
11B-246 OUTDOOR DEVELOPED AREAS
11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
581 DIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL
582 11B-304 TURNING SPACE
FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
583 FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE
584 FIGURE 11B-306.3 KNEE CLEARANCE
11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS
585 FIGURE 11B-307.4 VERTICAL CLEARANCE
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH
586 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
11B-309 OPERABLE PARTS
587 DIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
588 FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS, AND GATES
589 FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
590 FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
591 FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
592 TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
593 FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES
595 11B-405 RAMPS
596 FIGURE 11B-405.7 RAMP LANDINGS
FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
597 FIGURE 11B-406.2.2 SIDES OF CURB RAMPS
FIGURE 11B-406.3.2 PARALLEL CURB RAMPS
FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS
598 FIGURE 11B-406.5.7 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 11B-406.6 ISLANDS IN CROSSINGS
11B-407 ELEVATORS
599 FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS
600 FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCE
FIGURE 11B-407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES
601 TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
602 FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
603 TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION
604 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
605 FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL
606 11B-410 PLATFORM LIFTS
FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES
607 DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES
608 FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE
609 FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION
610 11B-503 PASSENGER DROP-OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE
611 11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS
612 FIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION
613 FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS
614 DIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS
615 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS
616 FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS
617 FIGURE 11B-604.7 DISPENSER OUTLET LOCATION
FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR
618 FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR
FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS
11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT
619 FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
620 11B-605 URINALS
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS
11B-606 LAVATORIES AND SINKS
11B-607 BATHTUBS
621 FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS
622 FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS
FIGURE 11B-607.5 BATHTUB CONTROL LOCATION
623 11B-608 SHOWER COMPARTMENTS
FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER
624 FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
625 11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
11B-610 SEATS
626 FIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS
627 FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS
628 DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS
629 TABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
630 FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT
631 FIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY
632 FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.5 CLEANER AIR SYMBOL
633 11B-704 TELEPHONES
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
634 FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES
635 FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
636 FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT
637 11B-708 TWO-WAY COMMUNICATION SYSTEMS
638 DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
639 FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING, AND LOCKER ROOMS
11B-804 KITCHENS AND KITCHENETTES
640 FIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS
641 11B-805 MEDICAL CARE AND LONG-TERM FACILITIES
642 11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS
643 11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS
644 11B-810 TRANSPORTATION FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS
645 FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE
646 DIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS
647 FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS
648 DIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
649 11B-1003 RECREATIONAL BOATING FACILITIES
650 FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
651 FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
652 11B-1004 EXERCISE MACHINES AND EQUIPMENT
11B-1005 FISHING PIERS AND PLATFORMS
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILITIES
653 11B-1007 MINIATURE GOLF FACILITIES
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
11B-1008 PLAY AREAS
655 FIGURE 11B-1008.3.1 TRANSFER PLATFORMS
FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS, AND SPAS
656 FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
657 FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT
658 FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
659 FIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
660 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT
662 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
664 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
665 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
666 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
667 SECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
SECTION 1212 [HCD 1] POLLUTANT CONTROL
SECTION 1213 RESERVED
SECTION 1214 RESERVED
SECTION 1215 RESERVED
SECTION 1216 RESERVED
SECTION 1217 RESERVED
SECTION 1218 RESERVED
668 SECTION 1219 RESERVED
SECTION 1220 RESERVED
SECTION 1221 RESERVED
SECTION 1222 RESERVED
SECTION 1223 RESERVED
SECTION 1224 [OSHPD 1] HOSPITALS
671 TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR1, 6
672 TABLE 1224.4.6.5 [OSHPD 1, 2, 3 & 4] LOCATION OF NURSE CALL DEVICES KEY: · Required
674 TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS
676 TABLE 1224.5 SOUND TRANSMISSION LIMITATIONS IN ACUTE CARE GENERAL HOSPITALS
699 SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES
707 SECTION 1226 [OSHPD 3] CLINICS
717 SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS
722 SECTION 1228 RESERVED
SECTION 1229 RESERVED
SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES
724 TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
726 SECTION 1231 [BSCC] LOCAL DETENTION
728 TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
732 SECTION 1232 RESERVED
SECTION 1233 RESERVED
SECTION 1234 RESERVED
SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS)
733 SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS
SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES
SECTION 1238 RESERVED
734 SECTION 1239 RESERVED
SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS
735 TABLE 1240.15.1
SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES
SECTION 1242 [AGR] RENDERERS
736 SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS
SECTION 1244 RESERVED
SECTION 1245 RESERVED
SECTION 1246 RESERVED
SECTION 1247 RESERVED
SECTION 1248 RESERVED
SECTION 1249 RESERVED
SECTION 1250 [CA] PHARMACIES
737 SECTION 1251 [CA] VETERINARY FACILITIES
SECTION 1252 [CA] BARBER COLLEGES AND SHOPS
738 SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS
SECTION 1254 [CA] ACUPUNCTURE OFFICES
740 CHAPTER 13 ENERGY EFFICIENCY
742 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS
744 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
745 SECTION 1404 MATERIALS
746 SECTION 1405 INSTALLATION OF WALL COVERINGS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
747 TABLE 1405.3.1 CLASS III VAPOR RETARDERS
751 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
752 SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
753 TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
754 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
755 SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 2 & 4] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER
758 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
760 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
761 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
762 TABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
763 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a
764 TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161
765 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
766 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
767 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
769 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
770 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
771 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
772 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
773 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
774 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOFTOP STRUCTURES
777 SECTION 1510 REROOFING
SECTION 1511 SOLAR PHOTOVOLTAIC PANELS/MODULES
SECTION 1512 [DSA-SS & DSA-SS/CC, OSHPD 1, 2 & 4] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS
780 INDEX
820 HISTORY NOTE APPENDIX
822 GET AHEAD WITH NEW TOOLS FOR YOUR CODE
CA BuildingCode vol1 2013
$155.46