CA BuildingCode vol1 2013
$155.46
California Building Code, Title 24 Part 2, Volume 1 (W/ ERRATA & SUPPLEMENT)
Published By | Publication Date | Number of Pages |
CA | 2013 | 823 |
The California Building Code (CBC) contains general building design and construction requirements relating to fire and life safety, structural safety, and access compliance. CBC provisions provide minimum standards to safeguard life or limb, health, property, and public welfare by regulating and controlling the design, construction, quality of materials, use and occupancy, location, and maintenance of all buildings and structures and certain equipment. Matrix Adoption tables are provided at beginning of every chapter in Part 2 to indicate which chapters and sections are adopted by state agencies (for application to their respective occupancies). This 2-volume set is a fully integrated code based on the 2012 International Building Code®. The CBC includes: Title 24, Part 8 California Historical Building Code (CHBC): contains regulations of the State Historical Building Safety Board. Provisions contained in the CHBC provide for the preservation, restoration, rehabilitation, relocation, or reconstruction of buildings or structures designated as qualified historical buildings or properties. The CHBC contains alternative solutions for the preservation of qualified historical buildings or properties, to provide access for persons with disabilities, to provide a cost-effective approach to preservation, and to provide for the reasonable safety of the occupants or users. Title 24, Part 10 California Building Standards Commission (CBSC): adopts certain provisions of the International Existing Building Code, Appendix Chapter A1, Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings.
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 |
2 | 2013 CALIFORNIA BUILDING CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2, VOLUME 1 OF 2 BASED ON THE 2012 INTERNATIONAL BUILDING CODE® TITLE PAGE |
3 | COPYRIGHT |
4 | PREFACE ACKNOWLEDGEMENTS |
5 | CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST |
6 | MARGINAL MARKINGS |
8 | EFFECTIVE USE OF THE IBC/CBC |
18 | HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS |
20 | CALIFORNIA MATRIX ADOPTION TABLES |
22 | TABLE OF CONTENTS |
36 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – ADMINISTRATION |
37 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – ADMINISTRATION—continued |
38 | CHAPTER 1 SCOPE AND ADMINISTRATION DIVISION I CALIFORNIA ADMINISTRATION SECTION 1.1 GENERAL |
40 | SECTION 1.2 BUILDING STANDARDS COMMISSION |
41 | SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS |
42 | SECTION 1.5 RESERVED SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT |
43 | SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS |
44 | SECTION 1.8.3 LOCAL ENFORCING AGENCY SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS |
45 | SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION |
46 | SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION SECTION 1.8.8 APPEALS BOARD |
47 | SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES |
48 | SECTION 1.8.10 OTHER BUILDING REGULATIONS SECTION 1.9 DIVISION OF THE STATE ARCHITECT |
50 | SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT |
52 | SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL |
56 | SECTION 1.12 STATE LIBRARIAN SECTION 1.13 RESERVED SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION |
58 | DIVISION II SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
59 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION 103 DEPARTMENT OF BUILDING SAFETY SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL |
61 | SECTION 105 PERMITS |
63 | SECTION 106 FLOOR AND ROOF DESIGN LOADS SECTION 107 SUBMITTAL DOCUMENTS |
64 | SECTION 108 TEMPORARY STRUCTURES AND USES |
65 | SECTION 109 FEES SECTION 110 INSPECTIONS |
66 | SECTION 111 CERTIFICATE OF OCCUPANCY SECTION 112 SERVICE UTILITIES |
67 | SECTION 113 BOARD OF APPEALS SECTION 114 VIOLATIONS SECTION 115 STOP WORK ORDER SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT |
70 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS |
71 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
72 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
73 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
74 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
75 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
76 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
77 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
78 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
79 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued |
80 | CHAPTER 2 DEFINITIONS SECTION 201 GENERAL SECTION 202 DEFINITIONS |
124 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION |
125 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – USE AND OCCUPANCY CLASSIFICATION—continued |
126 | CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION SECTION 301 GENERAL SECTION 302 CLASSIFICATION SECTION 303 ASSEMBLY GROUP A |
127 | SECTION 304 BUSINESS GROUP B SECTION 305 EDUCATIONAL GROUP E SECTION 306 FACTORY GROUP F |
128 | SECTION 307 HIGH-HAZARD GROUP H |
130 | [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
131 | [F] TABLE 307.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD |
132 | [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD |
133 | SECTION 308 INSTITUTIONAL GROUP I |
134 | SECTION 309 MERCANTILE GROUP M SECTION 310 RESIDENTIAL GROUP R |
136 | SECTION 311 STORAGE GROUP S |
137 | SECTION 312 UTILITY AND MISCELLANEOUS GROUP U SECTION 313 LABORATORIES GROUP L [SFM] |
138 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY |
139 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued |
140 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued |
141 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued |
142 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS ON USE AND OCCUPANCY—continued |
144 | CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY SECTION 401 SCOPE SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS |
148 | SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS |
149 | TABLE 403.2.4 MINIMUM BOND STRENGTH |
151 | SECTION 404 ATRIUMS SECTION 405 UNDERGROUND BUILDINGS |
153 | SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES |
154 | TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT |
157 | SECTION 407 GROUP I-2 |
160 | SECTION 408 GROUP I-3 |
165 | SECTION 409 MOTION PICTURE PROJECTION ROOMS |
166 | SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS |
168 | SECTION 411 SPECIAL AMUSEMENT BUILDINGS SECTION 412 AIRCRAFT-RELATED OCCUPANCIES TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS |
170 | [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS |
171 | SECTION 413 COMBUSTIBLE STORAGE SECTION 414 HAZARDOUS MATERIALS |
172 | [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS |
173 | [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd,e,f |
174 | [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5 |
175 | [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa |
177 | [F] TABLE 415.5.2 DETACHED BUILDING REQUIRED |
180 | [F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a |
185 | SECTION 416 APPLICATION OF FLAMMABLE FINISHES |
186 | SECTION 417 DRYING ROOMS SECTION 418 ORGANIC COATINGS SECTION 419 LIVE/WORK UNITS |
187 | SECTION 420 GROUPS R-1, R-2, R-2.1, R-3, R3.1 and R-4 |
190 | SECTION 421 HYDROGEN CUTOFF ROOMS SECTION 422 AMBULATORY CARE FACILITIES |
191 | SECTION 423 STORM SHELTERS SECTION 424 CHILDREN’S PLAY STRUCTURES SECTION 425 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM] |
194 | SECTION 426 GROUP I-4 [SFM] |
195 | SECTION 427 RESERVED SECTION 428 RESERVED SECTION 429 RESERVED SECTION 430 HORSE RACING STABLES [SFM] SECTION 431 PET KENNELS [SFM] SECTION 432 COMBUSTION ENGINES AND GAS TURBINES [SFM] |
196 | SECTION 433 FIXED GUIDEWAY TRANSIT SYSTEMS [SFM] |
199 | SECTION 434 EXPLOSIVES [SFM] |
202 | SECTION 435 RESERVED SECTION 436 WINERY CAVES [SFM] |
203 | SECTION 437 RESERVED SECTION 438 RESERVED SECTION 439 PUBLIC LIBRARIES [SL AND SFM] |
204 | SECTION 440 GROUP C [SFM] |
206 | SECTION 441 RESERVED SECTION 442 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE |
207 | SECTION 443 GROUP L [SFM] |
210 | TABLE 443.7.3.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE SECTION 444 RESERVED SECTION 445 LARGE FAMILY DAY-CARE HOMES [SFM] |
212 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS |
214 | CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS SECTION 501 GENERAL SECTION 502 DEFINITIONS SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS |
215 | TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREASa, b Building height limitations shown in feet above grade plane. Story limitations shown as stories above grade plane. Building area limitations shown in square feet, as determined by the definition of “Area, building,” per story |
216 | TABLE 503—continued ALLOWABLE BUILDING HEIGHTS AND AREASa, b FIGURE 5-1 |
217 | SECTION 504 BUILDING HEIGHT SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS |
218 | SECTION 506 BUILDING AREA MODIFICATIONS EQUATION 5-1 EQUATION 5-2 EQUATION 5-3 |
220 | SECTION 507 UNLIMITED AREA BUILDINGS |
221 | SECTION 508 MIXED USE AND OCCUPANCY |
222 | SECTION 509 INCIDENTAL USES |
223 | TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) SECTION 510 SPECIAL PROVISIONS |
224 | TABLE 509 INCIDENTAL USES |
228 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION |
230 | CHAPTER 6 TYPES OF CONSTRUCTION SECTION 601 GENERAL TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) SECTION 602 CONSTRUCTION CLASSIFICATION |
231 | TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES |
232 | SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION |
234 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES |
236 | CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 701 GENERAL SECTION 702 DEFINITIONS SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS |
237 | SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS |
239 | SECTION 705 EXTERIOR WALLS TABLE 705.2 MINIMUM DISTANCE OF PROJECTION |
240 | FIGURE 705.7 EQUIVALENT OPENING FACTOR EQUATION 7-1 |
241 | TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION |
242 | EQUATION 7-2 |
243 | SECTION 706 FIRE WALLS |
244 | TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS |
245 | SECTION 707 FIRE BARRIERS |
246 | TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS |
247 | SECTION 708 FIRE PARTITIONS |
248 | SECTION 709 SMOKE BARRIERS SECTION 710 SMOKE PARTITIONS |
249 | SECTION 711 HORIZONTAL ASSEMBLIES |
250 | SECTION 712 VERTICAL OPENINGS |
251 | SECTION 713 SHAFT ENCLOSURES |
253 | SECTION 714 PENETRATIONS |
256 | SECTION 715 FIRE-RESISTANT JOINT SYSTEMS |
257 | SECTION 716 OPENING PROTECTIVES TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES |
259 | TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
260 | TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS |
262 | TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS |
263 | SECTION 717 DUCTS AND AIR TRANSFER OPENINGS TABLE 717.3.2.1 FIRE DAMPER RATING |
268 | SECTION 718 CONCEALED SPACES |
270 | SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS |
271 | SECTION 721 PRESCRIPTIVE FIRE RESISTANCE |
272 | TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
273 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
274 | TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
275 | TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm |
276 | TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
277 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
278 | TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
279 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
280 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
281 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
282 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
283 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS |
284 | TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
285 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
286 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
287 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
288 | TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
289 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEM |
290 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
291 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
292 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
293 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
294 | TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS |
295 | SECTION 722 CALCULATED FIRE RESISTANCE |
296 | TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING EQUATION 7-3 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4 |
297 | TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS EQUATION 7-4 |
298 | FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL |
299 | TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches) FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS |
300 | EQUATION 7-5 FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS |
301 | FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES |
302 | TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches) TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE) TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb |
303 | TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches) |
304 | EQUATION 7-6 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS |
305 | EQUATION 7-7 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches) TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches) EQUATION 7-8 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS |
306 | TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS EQUATION 7-9 TABLE 722.4.1(3) VALUES OF Rn 0.59 TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a TABLE 722.4.1(5) REINFORCED MASONRY LINTELS |
307 | TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS EQUATION 7-10 EQUATION 7-11 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS |
308 | EQUATION 7-12 EQUATION 7-13 FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS |
309 | FIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM EQUATION 7-14 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD FIGURE 721.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS |
310 | FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS |
311 | TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS TABLE 722.5.1(2) PROPERTIES OF CONCRETE |
312 | TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
313 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
314 | TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES |
315 | TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
316 | TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS |
317 | TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS |
318 | TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)] |
319 | TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMALWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)] |
320 | EQUATION 7-15 EQUATION 7-16 |
321 | FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS EQUATION 7-17 |
322 | EQUATION 7-18 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES EQUATION 7-19 EQUATION 7-20 EQUATION 7-21 |
323 | TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION |
324 | FIGURE 722.6.3(1) LOAD FIGURE FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS |
326 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE |
328 | CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE SECTION 701A SCOPE, PURPOSE AND APPLICATION |
329 | SECTION 702A DEFINITIONS SECTION 703A STANDARDS OF QUALITY |
330 | SECTION 704A IGNITION-RESISTANT CONSTRUCTION |
331 | SECTION 705A ROOFING SECTION 706A VENTS SECTION 707A EXTERIOR COVERING |
333 | SECTION 708A EXTERIOR WINDOWS AND DOORS |
334 | SECTION 709A DECKING SECTION 710A ACCESSORY STRUCTURES |
336 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES |
338 | CHAPTER 8 INTERIOR FINISHES SECTION 801 GENERAL SECTION 802 DEFINITIONS SECTION 803 WALL AND CEILING FINISHES |
340 | TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk |
341 | SECTION 804 INTERIOR FLOOR FINISH SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION |
342 | SECTION 806 DECORATIVE MATERIALS AND TRIM SECTION 807 INSULATION SECTION 808 ACOUSTICAL CEILING SYSTEMS |
344 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS |
345 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
346 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
347 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
348 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
349 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
350 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS—continued |
352 | CHAPTER 9 FIRE PROTECTION SYSTEMS SECTION 901 GENERAL SECTION 902 DEFINITIONS |
353 | SECTION 903 AUTOMATIC SPRINKLER SYSTEMS |
355 | [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA |
357 | [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS |
361 | SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS |
363 | SECTION 905 STANDPIPE SYSTEMS [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE |
366 | SECTION 906 PORTABLE FIRE EXTINGUISHERS [F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS |
367 | [F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH SECTION 907 FIRE ALARM AND DETECTION SYSTEMS |
382 | [F] TABLE 907.5.2.3.3 VISIBLE ALARMS |
384 | SECTION 908 EMERGENCY ALARM SYSTEMS |
385 | SECTION 909 SMOKE CONTROL SYSTEMS |
387 | EQUATION 9-1 EQUATION 9-2 EQUATION 9-3 |
394 | SECTION 910 SMOKE AND HEAT REMOVAL |
395 | EQUATION 9-4 [F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa |
396 | SECTION 911 FIRE COMMAND CENTER |
397 | SECTION 912 FIRE DEPARTMENT CONNECTIONS |
398 | SECTION 913 FIRE PUMPS SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES SECTION 915 EMERGENCY RESPONDER RADIO COVERAGE |
400 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS |
401 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
402 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
403 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued |
404 | CHAPTER 10 MEANS OF EGRESS SECTION 1001 ADMINISTRATION SECTION 1002 DEFINITIONS SECTION 1003 GENERAL MEANS OF EGRESS |
406 | SECTION 1004 OCCUPANT LOAD |
407 | TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT SECTION 1005 MEANS OF EGRESS SIZING |
408 | SECTION 1006 MEANS OF EGRESS ILLUMINATION |
409 | SECTION 1007 ACCESSIBLE MEANS OF EGRESS |
412 | SECTION 1008 DOORS, GATES AND TURNSTILES |
413 | TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS |
419 | SECTION 1009 STAIRWAYS |
423 | SECTION 1010 RAMPS |
425 | SECTION 1011 EXIT SIGNS |
426 | SECTION 1012 HANDRAILS |
427 | SECTION 1013 GUARDS |
429 | SECTION 1014 EXIT ACCESS TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL |
430 | SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY |
431 | SECTION 1016 EXIT ACCESS TRAVEL DISTANCE TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa |
432 | SECTION 1017 AISLES SECTION 1018 CORRIDORS |
433 | TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING TABLE 1018.2 MINIMUM CORRIDOR WIDTH |
434 | SECTION 1019 EGRESS BALCONIES SECTION 1020 EXITS SECTION 1021 NUMBER OF EXITS |
435 | TABLE 1021.1 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS |
436 | TABLE 1021.2(1) (IFC [B] TABLE 1021.2(1)) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2, R-3 AND R-4 OCCUPANCIES TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES |
437 | SECTION 1023 EXIT PASSAGEWAYS |
438 | SECTION 1024 LUMINOUS EGRESS PATH MARKINGS |
439 | SECTION 1025 HORIZONTAL EXITS |
440 | SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS |
441 | SECTION 1027 EXIT DISCHARGE |
442 | SECTION 1028 ASSEMBLY |
443 | TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY |
445 | TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS |
447 | SECTION 1029 EMERGENCY ESCAPE AND RESCUE |
450 | CHAPTER 11 RESERVED |
452 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY |
454 | CHAPTER 11A HOUSING ACCESSIBILITY DIVISION I – APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS SECTION 1101A APPLICATION SECTION 1102A BUILDING ACCESSIBILITY |
455 | SECTION 1103A DESIGN AND CONSTRUCTION SECTION 1104A COVERED MULTIFAMILY DWELLINGS |
456 | SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES SECTION 1106A SITE AND BUILDING CHARACTERISTICS SECTION 1107A DEFINITIONS |
457 | DIVISION II – EXTERIOR FACILITIES SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL SECTION 1109A PARKING FACILITIES |
459 | SECTION 1110A EXTERIOR ROUTES OF TRAVEL |
460 | SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES SECTION 1113A WALKS AND SIDEWALKS ON AN ACCESSIBLE ROUTE |
461 | SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES |
462 | SECTION 1115A EXTERIOR STAIRWAYS |
463 | SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES |
464 | DIVISION III – BUILDING FEATURES SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY SECTION 1118A EGRESS AND AREAS OF REFUGE SECTION 1119A INTERIOR ROUTES OF TRAVEL SECTION 1120A INTERIOR ACCESSIBLE ROUTES |
465 | SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES |
466 | SECTION 1123A INTERIOR STAIRWAYS |
467 | SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS |
469 | SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES SECTION 1126A DOORS |
471 | SECTION 1127A COMMON USE FACILITIES |
479 | DIVISION IV – DWELLING UNIT FEATURES SECTION 1128A COVERED DWELLING UNITS SECTION 1129A RESERVED SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES SECTION 1132A DOORS |
481 | SECTION 1133A KITCHENS |
482 | SECTION 1134A BATHING AND TOILET FACILITIES |
485 | SECTION 1135A LAUNDRY ROOMS SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS |
486 | DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS SECTION 1137A OTHER FEATURES AND FACILITIES SECTION 1138A SPACE ALLOWANCES AND REACH RANGES |
488 | SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS |
489 | SECTION 1140A ACCESSIBLE TELEPHONES SECTION 1141A ACCESSIBLE SWIMMING POOLS |
490 | SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS SECTION 1143A SIGNAGE |
491 | TABLE 1143A.5 VISUAL CHARACTER HEIGHT |
492 | TABLE 1143A.7.1 BRAILLE DIMENSIONS SECTION 1144A RESERVED SECTION 1145A RESERVED SECTION 1146A RESERVED SECTION 1147A RESERVED SECTION 1148A RESERVED SECTION 1149A RESERVED |
493 | DIVISION VI – SITE IMPRACTICALITY TESTS SECTION 1150A SITE IMPRACTICALITY TESTS TEST NO. 1—INDIVIDUAL BUILDING TEST TEST NO. 2—SITE ANALYSIS TEST |
494 | TEST NO. 3—UNUSUAL CHARACTERISTICS TEST |
495 | DIVISION VII – FIGURES FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL |
496 | FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION |
497 | FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS |
498 | FIGURE 11A-1D WHEELCHAIR TURNING SPACE FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH |
499 | FIGURE 11A-1F CHANGE IN LEVEL |
500 | FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS |
501 | FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES |
502 | FIGURE 11A-1I FORWARD REACH |
503 | FIGURE 11A-1J SIDE REACH |
504 | FIGURE 11A-1K |
505 | FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE |
506 | FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS |
507 | FIGURE 11A-2C DIAGONAL PARKING STALLS |
508 | FIGURE 11A-3A CURB DETAILS |
509 | FIGURE 11A-3B CURB DETAIL |
510 | FIGURE 11A-3C CURB DETAIL |
511 | FIGURE 11A-3D CURB DETAIL |
512 | FIGURE 11A-3E CURB DETAIL |
513 | FIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60”³ WIDE FIGURE 11A-3G CURB DETAIL |
514 | FIGURE 11A-3H CURB DETAIL FIGURE 11A-3I CURB DETAIL |
515 | FIGURE 11A-3J CURB DETAIL FIGURE 11A-3K CURB DETAIL |
516 | FIGURE 11A-3L CURB SECTIONS |
517 | FIGURE 11A-5A RAMPS AND SIDEWALKS |
518 | FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS |
519 | FIGURE 11A-6B STAIR HANDRAILS |
520 | FIGURE 11A-6C RAMP DIMENSIONS |
521 | FIGURE 11A-6D RAMP LANDING AND DOORWAY |
522 | FIGURE 11A-6D RAMP LANDING AND DOORWAY |
523 | FIGURE 11A-6E STAIR HANDRAILS |
524 | FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS |
525 | FIGURE 11A-7B ELEVATOR CONTROL PANEL |
526 | FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES FIGURE 11A-7D GRAPH OF TIMING EQUATION |
527 | FIGURE 11A-8A FRONT APPROACHES—SWINGING DOORS FIGURE 11A-8B HINGE SIDE APPROACHES—SWINGING DOORS |
528 | FIGURE 11A-8C LATCH SIDE APPROACH—SWINGING DOORS FIGURE 11A-8D FRONT APPROACH—SLIDING DOORS AND FOLDING DOORS FIGURE 11A-8E SLIDE SIDE APPROACH—SLIDING DOORS AND FOLDING DOORS FIGURE 11A-8F LATCH SIDE APPROACH—SLIDING DOORS AND FOLDING DOORS |
529 | FIGURE 11A-8G VESTIBULE |
530 | FIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY) |
531 | FIGURE 11A-8I THRESHOLDS FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR |
532 | FIGURE 11A-9A TOILET FACILITIES |
533 | FIGURE 11A-9B WATER CLOSETS |
534 | FIGURE 11A-9C GRAB BARS |
535 | FIGURE 11A-9D KNEE AND TOE SPACE |
536 | FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS |
537 | FIGURE 11A-9F GRAB BARS AT BATHTUBS |
538 | FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS |
539 | FIGURE 11A-9H STANDARD ROLL-IN SHOWER |
540 | FIGURE 1A-9I SHOWER SEATS AND GRAB BARS |
541 | FIGURE 11A-9J OPEN SHOWER |
542 | FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER |
543 | FIGURE 11A-9L SHOWER WITH WATER CLOSET FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET |
544 | FIGURE 11A-10A KITCHEN SPECIFICATIONS |
545 | FIGURE 11A-11A DRINKING FOUNTAINS |
546 | FIGURE 11A-11B MOUNTING HEIGHTS AND CLEARANCES FOR TELEPHONES |
547 | FIGURE 11A-1E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS |
548 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLICLY FUNDED HOUSING |
550 | CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING DIVISION 1: APPLICATION AND ADMINISTRATION 11B-101 PURPOSE 11B-102 DIMENSIONS FOR ADULTS AND CHILDREN 11B-103 EQUIVALENT FACILITATION 11B-104 CONVENTIONS 11B-105 REFERENCED STANDARDS 11B-106 DEFINITIONS FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES |
552 | 11B-107 SPECIAL CONDITIONS APPEALS ACTION 11B-108 MAINTENANCE OF ACCESSIBLE FEATURES |
553 | DIVISION 2: SCOPING REQUIREMENTS 11B-201 APPLICATION 11B-202 EXISTING BUILDINGS AND FACILITIES |
555 | 11B-203 GENERAL EXCEPTIONS |
556 | 11B-204 PROTRUDING OBJECTS 11B-205 OPERABLE PARTS 11B-206 ACCESSIBLE ROUTES |
560 | 11B-207 ACCESSIBLE MEANS OF EGRESS 11B-208 PARKING SPACES |
561 | TABLE 11B-208.2 PARKING SPACES |
562 | 11B-209 PASSENGER LOADING ZONES AND BUS STOPS 11B-210 STAIRWAYS 11B-211 DRINKING FOUNTAINS |
563 | 11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS 11B-213 TOILET FACILITIES AND BATHING FACILITIES |
564 | 11B-214 WASHING MACHINES AND CLOTHES DRYERS 11B-215 FIRE ALARM SYSTEMS 11B-216 SIGNS |
566 | 11B-217 TELEPHONES TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES |
567 | 11B-218 TRANSPORTATION FACILITIES 11B-219 ASSISTIVE LISTENING SYSTEMS |
568 | 11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES 11B-221 ASSEMBLY AREAS TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS |
570 | 11B-222 DRESSING, FITTING AND LOCKER ROOMS 11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES |
571 | 11B-224 TRANSIENT LODGING GUEST ROOMS |
572 | TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES 11B-225 STORAGE |
573 | TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES 11B-226 DINING SURFACES AND WORK SURFACES 11B-227 SALES AND SERVICE TABLE 11B-227.2 CHECK-OUT AISLES |
574 | 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES AND FUEL DISPENSERS 11B-229 WINDOWS 11B-230 TWO-WAY COMMUNICATION SYSTEMS 11B-231 JUDICIAL FACILITIES 11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES |
575 | 11B-233 RESIDENTIAL FACILITIES |
577 | 11B-234 AMUSEMENT RIDES 11B-235 RECREATIONAL BOATING FACILITIES TABLE 11B-235.2 BOAT SLIPS |
578 | 11B-236 EXERCISE MACHINES AND EQUIPMENT 11B-237 FISHING PIERS AND PLATFORMS 11B-238 GOLF FACILITIES 11B-239 MINIATURE GOLF FACILITIES 11B-240 PLAY AREAS |
579 | TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES 11B-241 SAUNAS AND STEAM ROOMS 11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS 11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS 11B-244 RELIGIOUS FACILITIES |
580 | 11B-245 COMMERCIAL FACILITIES LOCATED IN PRIVATE RESIDENCES 11B-246 OUTDOOR DEVELOPED AREAS 11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE |
581 | DIVISION 3: BUILDING BLOCKS 11B-301 GENERAL 11B-302 FLOOR OR GROUND SURFACES FIGURE 11B-302.2 CARPET PILE HEIGHT FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES 11B-303 CHANGES IN LEVEL FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL |
582 | 11B-304 TURNING SPACE FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE 11B-305 CLEAR FLOOR OR GROUND SPACE FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE |
583 | FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH 11B-306 KNEE AND TOE CLEARANCE FIGURE 11B-306.2 TOE CLEARANCE |
584 | FIGURE 11B-306.3 KNEE CLEARANCE 11B-307 PROTRUDING OBJECTS FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS |
585 | FIGURE 11B-307.4 VERTICAL CLEARANCE 11B-308 REACH RANGES FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH |
586 | FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH 11B-309 OPERABLE PARTS |
587 | DIVISION 4: ACCESSIBLE ROUTES 11B-401 GENERAL 11B-402 ACCESSIBLE ROUTES 11B-403 WALKING SURFACES FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE |
588 | FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN 11B-404 DOORS, DOORWAYS, AND GATES |
589 | FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
590 | FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
591 | FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES |
592 | TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS |
593 | FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES |
595 | 11B-405 RAMPS |
596 | FIGURE 11B-405.7 RAMP LANDINGS FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION 11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS |
597 | FIGURE 11B-406.2.2 SIDES OF CURB RAMPS FIGURE 11B-406.3.2 PARALLEL CURB RAMPS FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS |
598 | FIGURE 11B-406.5.7 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS FIGURE 11B-406.6 ISLANDS IN CROSSINGS 11B-407 ELEVATORS |
599 | FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS |
600 | FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCE FIGURE 11B-407.2.3.2 CAR DESIGNATIONS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES |
601 | TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS |
602 | FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS |
603 | TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION |
604 | 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS |
605 | FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS 11B-409 PRIVATE RESIDENCE ELEVATORS FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL |
606 | 11B-410 PLATFORM LIFTS FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES |
607 | DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS 11B-501 GENERAL 11B-502 PARKING SPACES FIGURE 11B-502.2 VEHICLE PARKING SPACES |
608 | FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE |
609 | FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION |
610 | 11B-503 PASSENGER DROP-OFF AND LOADING ZONES FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE |
611 | 11B-504 STAIRWAYS FIGURE 11B-504.5 STAIR NOSINGS 11B-505 HANDRAILS |
612 | FIGURE 11B-505.4 HANDRAIL HEIGHT FIGURE 11B-505.5 HANDRAIL CLEARANCE FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION |
613 | FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS |
614 | DIVISION 6: PLUMBING ELEMENTS AND FACILITIES 11B-601 GENERAL 11B-602 DRINKING FOUNTAINS FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION 11B-603 TOILET AND BATHING ROOMS |
615 | 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS FIGURE 11B-604.2 WATER CLOSET LOCATION FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS |
616 | FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS |
617 | FIGURE 11B-604.7 DISPENSER OUTLET LOCATION FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR |
618 | FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS 11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT |
619 | FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE |
620 | 11B-605 URINALS FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS 11B-606 LAVATORIES AND SINKS 11B-607 BATHTUBS |
621 | FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS |
622 | FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS FIGURE 11B-607.5 BATHTUB CONTROL LOCATION |
623 | 11B-608 SHOWER COMPARTMENTS FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER |
624 | FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION |
625 | 11B-609 GRAB BARS FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION FIGURE 11B-609.3 SPACING OF GRAB BARS 11B-610 SEATS |
626 | FIGURE 11B-610.2 BATHTUB SEATS FIGURE 11B-610.3 EXTENT OF SEAT FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT 11B-611 WASHING MACHINES AND CLOTHES DRYERS |
627 | FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING 11B-612 SAUNAS AND STEAM ROOMS |
628 | DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES 11B-701 GENERAL 11B-702 FIRE ALARM SYSTEMS 11B-703 SIGNS FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS |
629 | TABLE 11B-703.3.1 BRAILLE DIMENSIONS FIGURE 11B-703.3.1 BRAILLE MEASUREMENT FIGURE 11B-703.3.2 POSITION OF BRAILLE FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND |
630 | FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT |
631 | FIGURE 11B-703.6.1 PICTOGRAM FIELD FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY |
632 | FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS FIGURE 11B-703.7.2.5 CLEANER AIR SYMBOL |
633 | 11B-704 TELEPHONES FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE |
634 | FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES |
635 | FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE 11B-706 ASSISTIVE LISTENING SYSTEMS 11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES |
636 | FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT |
637 | 11B-708 TWO-WAY COMMUNICATION SYSTEMS |
638 | DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS 11B-801 GENERAL 11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS |
639 | FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS 11B-803 DRESSING, FITTING, AND LOCKER ROOMS 11B-804 KITCHENS AND KITCHENETTES |
640 | FIGURE 11B-804.2.1 PASS THROUGH KITCHENS FIGURE 11B-804.2.2 U-SHAPED KITCHENS |
641 | 11B-805 MEDICAL CARE AND LONG-TERM FACILITIES |
642 | 11B-806 TRANSIENT LODGING GUEST ROOMS 11B-807 HOLDING CELLS AND HOUSING CELLS |
643 | 11B-808 COURTROOMS 11B-809 RESIDENTIAL DWELLING UNITS |
644 | 11B-810 TRANSPORTATION FACILITIES FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS FIGURE 11B-810.3 BUS SHELTERS |
645 | FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS 11B-811 STORAGE |
646 | DIVISION 9: BUILT-IN ELEMENTS 11B-901 GENERAL 11B-902 DINING SURFACES AND WORK SURFACES 11B-903 BENCHES FIGURE 11B-903.4 BENCH BACK SUPPORT 11B-904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS |
647 | FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS |
648 | DIVISION 10: RECREATION FACILITIES 11B-1001 GENERAL 11B-1002 AMUSEMENT RIDES FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES |
649 | 11B-1003 RECREATIONAL BOATING FACILITIES |
650 | FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS |
651 | FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS |
652 | 11B-1004 EXERCISE MACHINES AND EQUIPMENT 11B-1005 FISHING PIERS AND PLATFORMS FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS 11B-1006 GOLF FACILITIES |
653 | 11B-1007 MINIATURE GOLF FACILITIES FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA 11B-1008 PLAY AREAS |
655 | FIGURE 11B-1008.3.1 TRANSFER PLATFORMS FIGURE 11B-1008.3.2 TRANSFER STEPS 11B-1009 SWIMMING POOLS, WADING POOLS, AND SPAS |
656 | FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH |
657 | FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT |
658 | FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM |
659 | FIGURE 11B-1009.5.4 TRANSFER STEPS FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS FIGURE 11B-1009.5.7 GRAB BARS 11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS |
660 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT |
662 | CHAPTER 12 INTERIOR ENVIRONMENT SECTION 1201 GENERAL SECTION 1202 DEFINITIONS SECTION 1203 VENTILATION |
664 | SECTION 1204 TEMPERATURE CONTROL SECTION 1205 LIGHTING |
665 | SECTION 1206 YARDS OR COURTS SECTION 1207 SOUND TRANSMISSION SECTION 1208 INTERIOR SPACE DIMENSIONS |
666 | SECTION 1209 ACCESS TO UNOCCUPIED SPACES SECTION 1210 TOILET AND BATHROOM REQUIREMENTS |
667 | SECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS SECTION 1212 [HCD 1] POLLUTANT CONTROL SECTION 1213 RESERVED SECTION 1214 RESERVED SECTION 1215 RESERVED SECTION 1216 RESERVED SECTION 1217 RESERVED SECTION 1218 RESERVED |
668 | SECTION 1219 RESERVED SECTION 1220 RESERVED SECTION 1221 RESERVED SECTION 1222 RESERVED SECTION 1223 RESERVED SECTION 1224 [OSHPD 1] HOSPITALS |
671 | TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR1, 6 |
672 | TABLE 1224.4.6.5 [OSHPD 1, 2, 3 & 4] LOCATION OF NURSE CALL DEVICES KEY: · Required |
674 | TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS |
676 | TABLE 1224.5 SOUND TRANSMISSION LIMITATIONS IN ACUTE CARE GENERAL HOSPITALS |
699 | SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES |
707 | SECTION 1226 [OSHPD 3] CLINICS |
717 | SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS |
722 | SECTION 1228 RESERVED SECTION 1229 RESERVED SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES |
724 | TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES |
726 | SECTION 1231 [BSCC] LOCAL DETENTION |
728 | TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES |
732 | SECTION 1232 RESERVED SECTION 1233 RESERVED SECTION 1234 RESERVED SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS) |
733 | SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES SECTION 1238 RESERVED |
734 | SECTION 1239 RESERVED SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS |
735 | TABLE 1240.15.1 SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES SECTION 1242 [AGR] RENDERERS |
736 | SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS SECTION 1244 RESERVED SECTION 1245 RESERVED SECTION 1246 RESERVED SECTION 1247 RESERVED SECTION 1248 RESERVED SECTION 1249 RESERVED SECTION 1250 [CA] PHARMACIES |
737 | SECTION 1251 [CA] VETERINARY FACILITIES SECTION 1252 [CA] BARBER COLLEGES AND SHOPS |
738 | SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS SECTION 1254 [CA] ACUPUNCTURE OFFICES |
740 | CHAPTER 13 ENERGY EFFICIENCY |
742 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS |
744 | CHAPTER 14 EXTERIOR WALLS SECTION 1401 GENERAL SECTION 1402 DEFINITIONS SECTION 1403 PERFORMANCE REQUIREMENTS |
745 | SECTION 1404 MATERIALS |
746 | SECTION 1405 INSTALLATION OF WALL COVERINGS TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS |
747 | TABLE 1405.3.1 CLASS III VAPOR RETARDERS |
751 | SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS |
752 | SECTION 1407 METAL COMPOSITE MATERIALS (MCM) |
753 | TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS |
754 | SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL) |
755 | SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 2 & 4] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER |
758 | CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES |
760 | CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES SECTION 1501 GENERAL SECTION 1502 DEFINITIONS SECTION 1503 WEATHER PROTECTION |
761 | SECTION 1504 PERFORMANCE REQUIREMENTS TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION SECTION 1505 FIRE CLASSIFICATION |
762 | TABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION |
763 | SECTION 1506 MATERIALS SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D 7158a |
764 | TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D 3161 |
765 | TABLE 1507.2.9.2 VALLEY LINING MATERIAL |
766 | TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT |
767 | TABLE 1507.4.3(1) METAL ROOF COVERINGS TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE |
769 | TABLE 1507.7.6 SLATE SHINGLE HEADLAP |
770 | TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION |
771 | TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE |
772 | TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE |
773 | TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS |
774 | TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS SECTION 1508 ROOF INSULATION TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION SECTION 1509 ROOFTOP STRUCTURES |
777 | SECTION 1510 REROOFING SECTION 1511 SOLAR PHOTOVOLTAIC PANELS/MODULES SECTION 1512 [DSA-SS & DSA-SS/CC, OSHPD 1, 2 & 4] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS |
780 | INDEX |
820 | HISTORY NOTE APPENDIX |
822 | GET AHEAD WITH NEW TOOLS FOR YOUR CODE |