Shopping Cart

No products in the cart.

CA City of LA Building Code Vols1 2 2023 1stptg

$140.00

City of Los Angeles Building Code (2 Volumes) – Full Code

Published By Publication Date Number of Pages
CA 2023
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This package includes 2023 City of Los Angeles Building Code amendment pages, and the 2022 California Building Code (Title 24, Part 2, Volumes 1 and 2).

PDF Catalog

PDF Pages PDF Title
1 2022 CALIFORNIA BUILDING CODE VOLUME 1 OF 2 INCLUDING 2023 CITY OF LOS ANGELES AMENDMENTS©
2 2022 CALIFORNIA BUILDING CODE VOLUME 1 OF 2 INCLUDING 2023 CITY OF LOS ANGELES AMENDMENTS
3 COPYRIGHT
4 CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY OFFICES
CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY OFFICES
6 CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY PUBLISHED CODES
CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY PUBLISHED CODES
7 CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY MISSION STATEMENT
8 EFFECTIVE USE OF THE CITY OF LOS ANGELES BUILDING CODE
EFFECTIVE USE OF THE CITY OF LOS ANGELES BUILDING CODE
9 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
26 TABLE OF CONTENTS
TABLE OF CONTENTS
38 SECTION 6214 PORTABLE SIGNS (RESERVED)
44 LOS ANGELES ADMINISTRATIVE CODE DIVISION 19, CHAPTER 10
46 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION
47 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued
48 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION—continued
50 CHAPTER 1 SCOPE AND ADMINISTRATION ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
53 SECTION 1.2 BUILDING STANDARDS COMMISSION
54 SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS
SECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
55 SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
56 SECTION 1.8.3 LOCAL ENFORCING AGENCY
57 SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
58 SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS,TESTS AND METHODS OF CONSTRUCTION
59 SECTION 1.8.8 APPEALS BOARD
SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
60 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
62 SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT
64 SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
69 SECTION 1.12 STATE LIBRARIAN
SECTION 1.13 DEPARTMENT OF WATER RESOURCES RESERVED
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION
70 DIVISION II SCOPE AND ADMINISTRATION
SECTION 101 TITLE, PURPOSE AND SCOPE
72 SECTION 102 UNSAFE BUILDINGS OR STRUCTURES
SECTION 103 VIOLATIONS
SECTION 104 ORGANIZATION AND ENFORCEMENT
73 SECTION 105 APPEALS
76 SECTION 106 PERMITS
85 SECTION 107 FEES
90 SECTION 108 INSPECTION
92 SECTION 109 CERTIFICATE OF OCCUPANCY
93 SECTION 110 RESPONSIBILITY OF PERMITTEE
SECTION 111 CODE REVISION
SECTION 112 RESERVED
94 SECTION 113 PERMIT FEES
TABLE 1-A PERMIT FEES 1,2,3,4
TABLE 1-A.1 COMBINED PERMIT FEES
TABLE 1-B TEMPORARY CERTIFICATE OF OCCUPANCY ADDITIONAL FEES
95 TABLE 1-C REPORT FEES a,b,c,d,e
TABLE 1-D GRADING PERMIT FEES
96 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
97 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
98 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
99 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
100 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
101 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
102 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
103 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
104 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
105 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
106 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
156 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – OCCUPANCY CLASSIFICATION AND USE
158 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
159 SECTION 304 BUSINESS GROUP B
160 SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
161 SECTION 307 HIGH-HAZARD GROUP H
163 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
164 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
165 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARDa, c, f, h, i
SECTION 308 INSTITUTIONAL GROUP I
167 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
169 SECTION 311 STORAGE GROUP S
170 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM]
SECTION 314 ORGANIZED CAMPS GROUP C [SFM]
172 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
173 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE—continued
174 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE—continued
175 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLECHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE—continued
176 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
179 EQUATION 4-1
180 SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS
181 TABLE 403.2.3 MINIMUM BOND STRENGTH
183 SECTION 404 ATRIUMS
184 SECTION 405 UNDERGROUND BUILDINGS
185 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
188 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
190 SECTION 407 GROUP I-2 AND GROUP I-2.1
195 SECTION 408 GROUP I-3
198 TABLE 408.3.13 MAXIMUM FLOOR AREA ALLOWANCES FOR I-3 FACILITIESc
201 SECTION 409 MOTION PICTURE PROJECTION ROOMS
202 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
204 SECTION 411 SPECIAL AMUSEMENT AREAS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
206 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTSa, b, c
207 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
208 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
209 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
210 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA INGROUP M AND S OCCUPANCIES OF NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f
[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
211 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa, h
212 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
214 [F] TABLE 415.6.5 DETACHED BUILDING REQUIRED
216 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
221 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
222 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 ARTIFICIAL DECORATIVE VEGETATION
SECTION 420 GROUPS R-1, R-2, R-2.1, R-2.2, R-3, R-3.1 AND R-4
224 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACILITIES
225 SECTION 423 STORM SHELTERS
226 SECTION 424 PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS,GRAIN PROCESSING AND STORAGE
227 SECTION 427 MEDICAL GAS SYSTEMS
228 SECTION 435 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM]
231 SECTION 436 GROUP I-4 [SFM]
SECTION 437 RESERVED
232 SECTION 438 RESERVED
SECTION 439 ROAD TUNNELS, BRIDGES AND OTHER LIMITED-ACCESS HIGHWAYS [SFM]
SECTION 440 HORSE RACING STABLES [SFM]
SECTION 441 PET KENNELS AND PET BOARDING FACILITIES [SFM]
SECTION 442 COMBUSTION ENGINES AND GAS TURBINES [SFM]
SECTION 443 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS [SFM]
SECTION 444 EXPLOSIVES [SFM] [Section 444 has been repealed and replaced by the adoption of California Fire Code Chapter 56.]
233 SECTION 445 RESERVED
SECTION 446 WINERY CAVES [SFM]
234 SECTION 447 RESERVED
SECTION 448 RESERVED
SECTION 449 PUBLIC LIBRARIES [SL AND SFM]
SECTION 450 GROUP C [SFM]
236 SECTION 451 RESERVED
SECTION 452 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E CHILD CARE
238 SECTION 453 GROUP L [SFM]
240 TABLE 453.7.2.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
SECTION 454 RESERVED
SECTION 455 LARGE FAMILY DAY-CARE HOMES [SFM]
242 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
244 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
245 FIGURE 5-1
246 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
247 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE a, i
248 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b, n
249 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b, n
250 SECTION 506 BUILDING AREA
EQUATION 5-1
EQUATION 5-2
251 EQUATION 5-3
SECTION 507 UNLIMITED AREA BUILDINGS
252 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b, j
253 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b, j
254 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b, j
TABLE 506.3.3 FRONTAGE INCREASE FACTORa
255 TABLE 506.3.3.1 SECTION 507 BUILDINGSa
257 SECTION 508 MIXED USE AND OCCUPANCY
258 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)h
259 SECTION 509 INCIDENTAL USES
260 [F]TABLE 509.1 INCIDENTAL USES
261 SECTION 510 SPECIAL PROVISIONS
264 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
266 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
SECTION 602 CONSTRUCTION CLASSIFICATION
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
270 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
272 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
274 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE-USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
275 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
277 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
279 EQUATION 7-1
TABLE 705.5 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, d, g
280 EQUATION 7-2
FIGURE 705.7 EQUIVALENT OPENING FACTOR
281 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
282 SECTION 706 FIRE WALLS
283 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
285 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE-RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
287 SECTION 708 FIRE PARTITIONS
288 SECTION 709 SMOKE BARRIERS
289 SECTION 710 SMOKE PARTITIONS
290 SECTION 711 FLOOR AND ROOF ASSEMBLIES
SECTION 712 VERTICAL OPENINGS
292 SECTION 713 SHAFT ENCLOSURES
293 SECTION 714 PENETRATIONS
296 SECTION 715 JOINTS AND VOIDS
297 SECTION 716 OPENING PROTECTIVES
298 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
299 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
300 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
305 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
TABLE 717.3.2.1 FIRE DAMPER RATING
311 SECTION 718 CONCEALED SPACES
312 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
313 SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
314 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
315 SECTION 722 CALCULATED FIRE RESISTANCE
316 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
317 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
318 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
319 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
320 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
321 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
322 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
323 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
324 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
325 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
326 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
327 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
328 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
329 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
330 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa
331 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
332 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
333 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
334 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
335 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
336 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
337 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
338 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
339 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
340 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS,LOAD-BEARING OR NONLOAD-BEARING
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
EQUATION 7-3
EQUATION 7-4
341 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
342 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
343 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
EQUATION 7-5
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
344 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
345 FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
346 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc(APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
347 EQUATION 7-6
348 TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLSa, b, c, d
EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATEDREINFORCED CONCRETE MASONRY LINTELS (inches)
349 TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(3) VALUES OF Rn0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
350 TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-9
EQUATION 7-10
EQUATION 7-11
351 EQUATION 7-12
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
352 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(1)—continued W/D RATIOS FOR STEEL COLUMNS
353 TABLE 722.5.1(2) PROPERTIES OF CONCRETE
TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
354 TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
355 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FORTYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
356 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
357 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
358 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
359 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa[FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa[FIGURE 722.5.1(6)(c)]
360 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa[FIGURE 722.5.1 (6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa[FIGURE 722.5.1 (6)(a)]
361 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
362 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa, b
363 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-13
EQUATION 7-14
364 EQUATION 7-15
EQUATION 7-16
365 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
366 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a, b, c
367 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
368 TABLE 722.7.1(1) PROTECTION REQUIRED FROM NONCOMBUSTIBLE COVERING MATERIAL
TABLE 722.7.1(2) PROTECTION PROVIDED BY NONCOMBUSTIBLE COVERING MATERIAL
370 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION 701A SCOPE, PURPOSE AND APPLICATION
371 SECTION 702 A DEFINITIONS
372 SECTION 703A STANDARDS OF QUALITY
373 SECTION 704A IGNITION-RESISTANT CONSTRUCTION
SECTION 705A ROOFING
374 SECTION 706A VENTS
SECTION 707A EXTERIOR COVERING
377 SECTION 708A EXTERIOR WINDOWS, SKYLIGHTS AND DOORS
378 SECTION 709A DECKING
SECTION 710A ACCESSORY BUILDINGS AND MISCELLANEOUS STRUCTURES
380 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
382 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
384 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
385 SECTION 804 INTERIOR FLOOR FINISH
386 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
387 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
388 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS
389 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
390 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
391 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
392 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
393 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
394 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
395 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
397 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
400 [F]TABLE 903.2.11.6 ADDITIONAL REQUIRED PROTECTION SYSTEMS
404 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
407 SECTION 905 STANDPIPE SYSTEMS
410 SECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE
411 [F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
412 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
427 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
429 SECTION 908 EMERGENCY ALARM SYSTEMS
430 SECTION 909 SMOKE CONTROL SYSTEMS
431 EQUATION 9-1
432 EQUATION 9-2
438 SECTION 910 SMOKE AND HEAT REMOVAL
439 EQUATION 9-3
EQUATION 9-4
440 SECTION 911 FIRE COMMAND CENTER
441 SECTION 912 FIRE DEPARTMENT CONNECTIONS
442 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
443 SECTION 915 CARBON MONOXIDE DETECTION
445 SECTION 916 GAS DETECTION SYSTEMS
446 SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER COMMUNICATION COVERAGE
448 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
449 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
450 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
451 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
452 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
454 SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
455 SECTION 1005 MEANS OF EGRESS SIZING
456 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
457 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
459 TABLE 1006.3.3 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.4(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 AND R-3 OCCUPANCIES
460 TABLE 1006.3.4(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
462 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
465 SECTION 1010 DOORS, GATES AND TURNSTILES
473 TABLE 1010.3.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.3.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
475 SECTION 1011 STAIRWAYS
479 SECTION 1012 RAMPS
480 SECTION 1013 EXIT SIGNS
482 SECTION 1014 HANDRAILS
483 SECTION 1015 GUARDS
485 SECTION 1016 EXIT ACCESS
486 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
487 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
488 SECTION 1020 CORRIDORS
TABLE 1020.2 CORRIDOR FIRE-RESISTANCE RATING
489 TABLE 1020.3 MINIMUM CORRIDOR WIDTH
490 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
492 SECTION 1024 EXIT PASSAGEWAYS
493 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
495 SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
496 SECTION 1028 EXIT DISCHARGE
497 SECTION 1029 EGRESS COURTS
SECTION 1030 ASSEMBLY
499 TABLE 1030.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
502 TABLE 1030.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
505 SECTION 1031 EMERGENCY ESCAPE AND RESCUE
508 CHAPTER 11 RESERVED
510 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY
512 CHAPTER 11A HOUSING ACCESSIBILITY
DIVISION I – APPLICATION, GENERAL PROVISIONS AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY
513 SECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS
514 SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS
515 DIVISION II – EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES
517 SECTION 1110A EXTERIOR ACCESSIBLE ROUTES
518 SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES
519 SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
520 SECTION 1115A EXTERIOR STAIRWAYS
521 SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES
523 DIVISION III – BUILDING FEATURES
SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY
SECTION 1118A EGRESS AND AREAS OF REFUGE
SECTION 1119A INTERIOR ACCESSIBLE ROUTES
524 SECTION 1120A RESERVED
SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
525 SECTION 1123A INTERIOR STAIRWAYS
526 SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
527 TABLE 1124A.3.2 ELEVATOR CAR DIMENSIONS
529 SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
SECTION 1126A DOORS, GATES AND WINDOWS
531 SECTION 1127A COMMON USE FACILITIES
540 DIVISION IV – DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS
542 SECTION 1133A KITCHENS
543 SECTION 1134A BATHING AND TOILET FACILITIES
546 SECTION 1135A LAUNDRY ROOMS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
547 DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS
SECTION 1137A OTHER FEATURES AND FACILITIES
SECTION 1138A SPACE ALLOWANCES AND REACH RANGES
549 SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS
550 SECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS
551 SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE
552 TABLE 1143A.5 VISUAL CHARACTER HEIGHT
553 TABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED
554 DIVISION VI – SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1—INDIVIDUAL BUILDING TEST
TEST NO. 2—SITE ANALYSIS TEST
556 DIVISION VII – FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL
557 FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION
558 FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS
559 FIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH
560 FIGURE 11A-1F CHANGE IN LEVEL
561 FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS
562 FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES
563 FIGURE 11A-1I FORWARD REACH
564 FIGURE 11A-1J SIDE REACH
565 FIGURE 11A-1K MINIMUM CLEARANCES FOR SEATING AND TABLE
566 FIGURE 11A-1 LINTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE
567 FIGURE 11A-2A DOUBLE PARKING STALLS
FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS
568 FIGURE 11A-2C DIAGONAL PARKING STALLS
569 FIGURE 11A-3A CURB DETAILS
570 FIGURE 11A-3B CURB DETAIL
571 FIGURE 11A-3C CURB DETAIL
572 FIGURE 11A-3D CURB DETAIL
FIGURE 11A-3E CURB DETAIL
573 FIGURE 11A-3F CURB DETAIL – SIDEWALK LESS THAN 60″ WIDE
FIGURE 11A-3G CURB DETAIL
574 FIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL
575 FIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL
576 FIGURE 11A-3L CURB SECTIONS
577 FIGURE 11A-5A RAMPS AND SIDEWALKS
578 FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS
579 FIGURE 11A-6B HANDRAILS
580 FIGURE 11A-6C RAMP DIMENSIONS
581 FIGURE 11A-6D RAMP LANDING AND DOORWAY
582 FIGURE 11A-6E STAIR HANDRAILS
583 FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS
584 FIGURE 11A-7B ELEVATOR CONTROL PANEL
585 FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION
586 FIGURE 11A-8A MANEUVERING CLEARANCE AT SWINGING DOORS
587 FIGURE 11A-8B MANEUVERING CLEARANCE AT DOORWAYS, SLIDING DOORS AND FOLDING DOORS
588 FIGURE 11A-8C MANEUVERING CLEARANCES AT RECESSED DOORS
589 FIGURE 11A-8G VESTIBULE
590 FIGURE 11A-8H VESTIBULE
591 FIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR
592 FIGURE 11A-9A TOILET FACILITIES
593 FIGURE 11A-9B WATER CLOSETS
594 FIGURE 11A-9C GRAB BARS
595 FIGURE 11A-9D KNEE AND TOE SPACE
596 FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS
597 FIGURE 11A-9F GRAB BARS AT BATHTUBS
598 FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS
599 FIGURE 11A-9H STANDARD ROLL-IN SHOWER
600 FIGURE 1A-9I SHOWER SEATS AND GRAB BARS
601 FIGURE 11A-9J OPEN SHOWER
602 FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER
603 FIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9 MWING WALL OR CABINET AT WATER CLOSET
604 FIGURE 11A-10A KITCHEN SPECIFICATIONS
605 FIGURE 11A-11A DRINKING FOUNTAINS
606 FIGURE 11A-11B TELEPHONES
607 FIGURE 11A-11C INTERNATIONAL TTY SYMBOL
FIGURE 11A-11D VOLUME CONTROL TELEPHONES
FIGURE 11A-11E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
608 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,COMMERCIAL BUILDINGS AND PUBLIC HOUSING
610 CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS,PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES
612 11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES
613 DIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES
615 11B-203 GENERAL EXCEPTIONS
616 11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
FIGURE 11B-205.1 Ex. 9 ELECTRICAL RECEPTACLES AT CORNER WORKSURFACES
11B-206 ACCESSIBLE ROUTES
621 11B-207 ACCESSIBLE MEANS OF EGRESS
11B-208 PARKING SPACES
TABLE 11B-208.2 PARKING SPACES
622 11B-209 PASSENGER DROP-OFF AND LOADING ZONES AND BUS STOPS
623 11B-210 STAIRWAYS
11B-211 DRINKING FOUNTAINS AND BOTTLE FILLING STATIONS
11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS
11B-213 TOILET FACILITIES AND BATHING FACILITIES
624 11B-214 WASHING MACHINES AND CLOTHES DRYERS
11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS
625 11B-216 SIGNS
626 11B-217 TELEPHONES
627 TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES
11B-218 TRANSPORTATION FACILITIES
628 11B-219 ASSISTIVE LISTENING SYSTEMS
11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
11B-221 ASSEMBLY AREAS
629 TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
630 11B-222 DRESSING, FITTING AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES
631 11B-224 TRANSIENT LODGING GUEST ROOMS, HOUSING AT A PLACE OF EDUCATION AND SOCIAL SERVICE CENTER ESTABLISHMENTS
632 TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES
TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES
11B-225 STORAGE
633 TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES
11B-226 DINING SURFACES AND WORK SURFACES
11B-227 SALES AND SERVICE
TABLE 11B-227.2 CHECK-OUT AISLES
634 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, FUEL DISPENSERS AND ELECTRIC VEHICLE CHARGING STATIONS
TABLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC USE AND COMMON USE
635 11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATION SYSTEMS
11B-231 JUDICIAL FACILITIES
11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES
636 11B-233 PUBLIC HOUSING FACILITIES
639 11B-234 AMUSEMENT RIDES
11B-235 RECREATIONAL BOATING FACILITIES
640 TABLE 11B-235.2 BOAT SLIPS
11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
11B-240 PLAY AREAS
641 TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
11B-242 SWIMMING POOLS, WADING POOLS AND SPAS
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
642 11B-244 RELIGIOUS FACILITIES
11B-245 PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RESIDENCES
11B-246 OUTDOOR DEVELOPED AREAS
11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
11B-248 COMMON USE AREAS AND EMPLOYEE WORK AREAS
643 11B-249 ADULT CHANGING FACILITIES
11B-250 CIRCULATION PATHS
644 DIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
11B-304 TURNING SPACE
645 FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
646 FIGURE 11B-305.7.2 MANEUVERING CLEARANCE INAN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE
FIGURE 11B-306.3 KNEE CLEARANCE
647 FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS
648 FIGURE 11B-307.4 VERTICAL CLEARANCE
FIGURE 11B-307.4.1 GUY BRACES
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH
649 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
TABLE 11B-308.4 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-309 OPERABLE PARTS
650 DIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
651 FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS AND GATES
652 FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
653 FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
654 FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
655 TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS ORGATES, MANUAL SLIDING DOORS and MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES and FOLDING DOORS
656 FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES
658 11B-405 RAMPS
659 FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
FIGURE 11B-405.7 RAMP LANDINGS
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
660 FIGURE 11B-406.2.2 SIDES OF CURB RAMPS
FIGURE 11B-406.3.2 PARALLEL CURB RAMPS
FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS
661 FIGURE 11B-406.5.8 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 11B-406.6 ISLANDS IN CROSSINGS
11B-407 ELEVATORS
662 FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS
663 FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES
TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
664 FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
665 TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION
666 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
667 FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
668 11B-410 PLATFORM LIFTS
11B-411 DESTINATION-ORIENTED ELEVATORS
669 FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION
672 FIGURE 11B-411.2.3 FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF DESTINATION-ORIENTEDELEVATOR HOISTWAY ENTRANCES
674 DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES
675 FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE
676 FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION
677 11B-503 PASSENGER DROP-OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE
678 11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS
679 FIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION
680 FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS
681 DIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS AND BOTTLE FILLING STATIONS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS
682 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS
683 FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.1 DISPENSER OUTLET LOCATION
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.2 DISPOSAL UNIT LOCATION
684 FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR
685 FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR
FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS
686 FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT
687 TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-605 URINALS
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS
11B-606 LAVATORIES AND SINKS
688 11B-607 BATHTUBS
FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS
689 FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS
690 FIGURE 11B-607.5 BATHTUB CONTROL LOCATION
11B-608 SHOWER COMPARTMENTS
FIGURE 11B-608.2.1 TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
691 FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.3.1 GRAB BARS FOR TRANSFER TYPE SHOWERS
FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER
FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS
692 FIGURE 11B-608.5.1 TRANSFER TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
693 11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
11B-610 SEATS
694 FIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS
695 FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS
696 DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS
697 TABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
698 FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT
699 FIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY
700 FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.6.4 EDGES AND VERTICES ON GEOMETRIC SYMBOLS
701 TABLE 11B-703.8.5 PIXEL COUNT FOR LOW RESOLUTION VMS
TABLE 11B-703.8.4 LOW RESOLUTION VMS CHARACTER HEIGHT
11B-704 TELEPHONES
702 FIGURE 11B-703.8.5 LOW RESOLUTION VMS CHARACTERS
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
703 11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES
704 FIGURE 11B-705.1.2.2.2 PARALLEL CURB RAMPS
705 FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT-OF-SALE DEVICES
706 FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT
707 11B-708 TWO-WAY COMMUNICATION SYSTEMS
708 DIVISION 8: SPECIAL ROOMS, SPACES AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
709 FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING AND LOCKER ROOMS
11B-804 KITCHENS, KITCHENETTES AND WET BARS
710 FIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS
711 11B-805 MEDICAL CARE AND LONG-TERM CARE FACILITIES
712 11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS
713 11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS
714 FIGURE 11B-809.8 Ex. 1(c) PLATFORM AT SECONDARY EXTERIOR DOOR
715 FIGURE 11B-809.8 Ex. 1(d) RAMP AT SECONDARY EXTERIOR DOOR
716 FIGURE 11B-809.9.2 CLEAR WIDTH AT KITCHENS
717 FIGURE 11B-809.10.5.2 REINFORCEMENT FOR GRAB BARS
718 FIGURE 11B-809.10.6.1 SHOWERS
FIGURE 11B-809.10.7.1 FLOOR SPACE
FIGURE 11B-809.10.6.4 REINFORCEMENT FOR GRAB BARS
719 FIGURE 11B-809.10.7.3 REINFORCEMENT FOR GRAB BARS
720 FIGURE 11B-809.12 ELECTRICAL RECEPTACLES AT CORNER WORKSURFACES
11B-810 TRANSPORTATION FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS
721 FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE
11B-812 ELECTRIC VEHICLE CHARGING STATIONS
723 FIGURE 11B-812.9 SURFACE MARKING
724 11B-813 ADULT CHANGING FACILITIES
FIGURE 11B-813.2.1.2 CLEARANCE AROUND ADULT CHANGING TABLE
725 DIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK-OUT AISLES AND SALES AND SERVICE COUNTERS
FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
726 FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS
727 DIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
728 11B-1003 RECREATIONAL BOATING FACILTIES
729 FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
730 FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
11B-1004 EXERCISE MACHINES AND EQUIPMENT
731 11B-1005 FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILTIES
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
732 11B-1007 MINIATURE GOLF FACILITIES
11B-1008 PLAY AREAS
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
733 FIGURE 11B-1008.3.1 TRANSFER PLATFORMS
734 FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS AND SPAS
FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
735 FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
736 FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT
FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
737 FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
738 FIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
740 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT
741 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT—continued
742 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
744 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
TABLE 1202.3.1 IECC VERSUS CALIFORNIA ENERGY CODE CLIMATE ZONE COMPARISON
745 SECTION 1203 TEMPERATURE CONTROL
746 SECTION 1204 LIGHTING
SECTION 1205 YARDS OR COURTS
747 SECTION 1206 SOUND TRANSMISSION
750 SECTION 1207 ENHANCED CLASSROOM ACOUSTICS
SECTION 1208 INTERIOR SPACE DIMENSIONS
752 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
753 SECTION 1211 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
754 SECTION 1212 [HCD 1] POLLUTANT CONTROL
SECTION 1213 RESERVED
SECTION 1214 RESERVED
SECTION 1215 RESERVED
SECTION 1216 RESERVED
SECTION 1217 RESERVED
SECTION 1218 RESERVED
SECTION 1219 RESERVED
SECTION 1220 RESERVED
SECTION 1221 RESERVED
SECTION 1222 RESERVED
SECTION 1223 RESERVED
SECTION 1224 [OSHPD 1] HOSPITALS
760 TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION) AND MEDICAL AIR SYSTEMS1, 6
761 TABLE 1224.4.6.5[OSHPD 1, 2, 3, 4 & 5] LOCATION OF NURSE CALL DEVICES• = Required
764 TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS
765 TABLE 1224.4.11.4a EXAMINATION/TREATMENT, IMAGING, PROCEDURE AND OPERATING ROOM CLASSIFICATION1, 2
768 TABLE 1224.4.19 SOUND TRANSMISSION LIMITATIONS IN HOSPITALS
806 SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES
815 SECTION 1226 [OSHPD 3] CLINICS
826 SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS
831 SECTION 1228 [OSHPD 5] ACUTE PSYCHIATRIC HOSPITALS
838 SECTION 1229 RESERVED
SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES
839 TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
842 SECTION 1231 [BSCC] LOCAL DETENTION
843 TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
848 SECTION 1232 RESERVED
SECTION 1233 RESERVED
SECTION 1234 RESERVED
SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS)
849 SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS
SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES
SECTION 1238 RESERVED
SECTION 1239 RESERVED
SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS
850 TABLE 1240.15.1
851 SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES
SECTION 1242 [AGR] RENDERERS
SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS
852 SECTION 1244 RESERVED
SECTION 1245 RESERVED
SECTION 1246 RESERVED
SECTION 1247 RESERVED
SECTION 1248 RESERVED
SECTION 1249 RESERVED
SECTION 1250 [CA] PHARMACIES
853 SECTION 1251 [CA] VETERINARY FACILITIES
SECTION 1252 [CA] BARBER COLLEGES AND SHOPS
SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY,COSMETOLOGICAL ESTABLISHMENTS ANDSATELLITE CLASSROOMS
854 SECTION 1254 [CA] ACUPUNCTURE OFFICES
856 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1300 GENERAL
SECTION 1301 SOLAR ENERGY COLLECTORS
858 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS
860 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
861 SECTION 1403 MATERIALS
862 SECTION 1404 INSTALLATION OF WALL COVERINGS
TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
863 TABLE 1404.3(1) VAPOR RETARDER MATERIALS AND CLASSES
TABLE 1404.3(2) VAPOR RETARDER OPTIONS
TABLE 1404.3(3) CLASS III VAPOR RETARDERS
TABLE 1404.3(4) CONTINUOUS INSULATION WITH CLASS II VAPOR RETARDER
868 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
869 TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
870 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
871 SECTION 1409 PLASTIC COMPOSITE DECKING
SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] ADDITIONAL REQUIREMENTS FORANCHORED AND ADHERED VENEER
872 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
874 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
875 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.2 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161OR D7158
876 TABLE 1504.9 MINIMUM REQUIRED PARAPET HEIGHT (INCHES) FOR AGGREGATE SURFACED ROOFSa, b, c
SECTION 1505 FIRE CLASSIFICATION
877 TABLE 1505.1 MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTIONa
878 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
TABLE 1507.1.1(1) UNDERLAYMENT TYPES
879 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
880 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
881 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
883 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa, b, c
884 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
885 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
886 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
887 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
888 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.12.2 SINGLE-PLY ROOFING MATERIAL STANDARDS
TABLE 1507.13.3 PROTECTIVE COATING MATERIAL STANDARDS
889 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
890 SECTION 1509 ROOF COATINGS
TABLE 1509.2 ROOF COATING MATERIAL STANDARDS
SECTION 1510 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1511 ROOFTOP STRUCTURES
892 [BF] TABLE 1512.1 ALLOWABLE REROOFS OVER EXISTING ROOFING
893 SECTION 1512 REROOFING
SECTION 1513 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS
896 INDEX
938 HISTORY NOTE APPENDIX
940 CODE RESOURCES FROM ICC
941 ICC DIGITAL CODES PREMIUM
942 2022 CALIFORNIA BUILDING CODE VOLUME 2 OF 2 INCLUDING 2023 CIT OF LOS ANGELES AMENDMENTS
943 2022 CALIFORNIA BUILDING CODE VOLUME 2 OF 2 INCLUDING 2023 CITY OF LOS ANGELES AMENDMENTS
944 COPYRIGHT
971 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 16 – STRUCTURAL DESIGN
973 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
974 SECTION 1603 CONSTRUCTION DOCUMENTS
975 SECTION 1604 GENERAL DESIGN REQUIREMENTS
976 TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i
977 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
978 SECTION 1605 LOAD COMBINATIONS
979 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
980 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
981 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
982 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
984 EQUATION 16-7
TABLE 1607.12.1 LIVE LOAD ELEMENT FACTOR, KLL
985 EQUATION 16-8
EQUATION 16-9
986 EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
988 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
989 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
990 FIGURE 1608.2(1) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
991 FIGURE 1608.2(2) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
992 EQUATION 16-17
993 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
994 FIGURE 1609.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
995 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
996 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
997 EQUATION 16-18
TABLE 1609.3.1 WIND SPEED CONVERSIONSa, b, c
SECTION 1610 SOIL LOADS AND HYDROSTATIC PRESSURE
998 SECTION 1611 RAIN LOADS
EQUATION 16-19
TABLE 1610.1 LATERAL SOIL LOAD
999 FIGURE 1611.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
1000 FIGURE 1611.1(2)100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
1001 FIGURE 1611.1(3)100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
1002 FIGURE 1611.1(4)100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
1003 FIGURE 1611.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
1004 SECTION 1612 FLOOD LOADS
SECTION 1613 EARTHQUAKE LOADS
1005 EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
EQUATION 16-23
1006 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THECONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1007 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THECONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1008 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THECONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1009 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THECOTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1010 FIGURE 1613.2.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1011 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1012 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
1013 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION(5% OF CRITICAL DAMPING)
1014 FIGURE 1613.2.1(9) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION(5% OF CRITICAL DAMPING)
1015 FIGURE 1613.2.1(10) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONSFOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION(5% OF CRITICAL DAMPING)
1016 TABLE 1613.2.3(1) [OSHPD 1R, 2 & 5] VALUES OF SITE COEFFICIENT Faa
TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT FVa
1017 TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
1022 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
SECTION 1616 STRUCTURAL INTEGRITY
1023 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
EQUATION 16-24
1024 EQUATION 16-25
SECTION 1617 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1025 EQUATION 3-5A
1033 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 16A – STRUCTURAL DESIGN
1035 CHAPTER 16A STRUCTURAL DESIGN
SECTION 1601A GENERAL
SECTION 1602A NOTATIONS
SECTION 1603A CONSTRUCTION DOCUMENTS
1037 SECTION 1604A GENERAL DESIGN REQUIREMENTS
1038 TABLE 1604A.3 DEFLECTION LIMITSa, b, c, h, i
1039 TABLE 1604A.4 MAXIMUM HORIZONTAL DIAPHRAGM SPAN AND SPAN-DEPTH RATIOS1, 3, 4
1040 TABLE 1604A.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
1041 SECTION 1605A LOAD COMBINATIONS
1042 EQUATION 16A-1
EQUATION 16A-2
EQUATION 16A-3
EQUATION 16A-4
EQUATION 16A-5
EQUATION 16A-6
EQUATION 3-5A
SECTION 1606A DEAD LOADS
SECTION 1607A LIVE LOADS
1043 TABLE 1607A.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1044 TABLE 1607A.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1045 TABLE 1607A.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADS
1047 EQUATION 16A-7
1048 TABLE 1607A.12.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16A-8
EQUATION 16A-9
1049 EQUATION 16A-10
EQUATION 16A-11
EQUATION 16A-12
EQUATION 16A-13
EQUATION 16A-14
EQUATION 16A-15
EQUATION 16A-16
1051 SECTION 1608A SNOW LOADS
1052 FIGURE 1608A.2(1) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
1053 FIGURE 1608A.2(2) GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
1054 SECTION 1609A WIND LOADS
TABLE 1609A.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
1055 EQUATION 16A-17
1057 FIGURE 1609A.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
1058 FIGURE 1609A.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
1059 FIGURE 1609A.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
1060 FIGURE 1609A.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
1061 TABLE 1609A.3.1 WIND SPEED CONVERSIONSa, b, c
EQUATION 16A-18
SECTION 1610A SOIL LOADS AND HYDROSTATIC PRESSURE
1062 TABLE 1610A.1 LATERAL SOIL LOAD
SECTION 1611A RAIN LOADS
EQUATION 16A-19
1063 SECTION 1612A FLOOD LOADS
1064 FIGURE 1611A.1(1) 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
1065 FIGURE 1611A.1(2)100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
1066 FIGURE 1611A.1(3) 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
1067 FIGURE 1611A.1(4) 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
1068 FIGURE 1611A.1(5) 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
1069 SECTION 1613A EARTHQUAKE LOADS
EQUATION 16A-20
EQUATION 16A-21
EQUATION 16A-22
EQUATION 16A-23
SECTION 1614A ATMOSPHERIC ICE LOADS
1070 TABLE 1613A.2.3(1) VALUES OF SITE COEFFICIENT Faa
TABLE 1613A.2.3(2) VALUES OF SITE COEFFICIENT FVa
SECTION 1615A TSUNAMI LOADS
SECTION 1616A STRUCTURAL INTEGRITY
1071 FIGURE 1616A.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
1072 EQUATION 16A-25
EQUATION 16A-24
SECTION 1617A MODIFICATIONS TO ASCE 7
1083 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17 – SPECIAL INSPECTIONS AND TESTS
1084 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17 – SPECIAL INSPECTIONS AND TESTS—continued
1085 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
1086 SECTION 1704 SPECIAL INSPECTIONS AND TESTS,CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
1091 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
1093 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
1095 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
1098 TABLE 1705.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
1099 TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
1100 TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
1103 TABLE 1705.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
1106 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
1107 SECTION 1709 PRECONSTRUCTION LOAD TESTS
1108 SECTION 1710 CERTIFIED SECURITY BAR INSTALLER
1109 SECTION 1711 PREFABRICATED CONSTRUCTION
1111 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 17A – SPECIAL INSPECTIONS AND TESTS
1113 CHAPTER 17A SPECIAL INSPECTIONS AND TESTS
SECTION 1701A GENERAL
SECTION 1702A NEW MATERIALS
SECTION 1703A APPROVALS
1114 SECTION 1704A SPECIAL INSPECTIONS AND TESTS,CONTRACTOR RESPONSIBILITY ANDSTRUCTURAL OBSERVATION
1116 SECTION 1705A REQUIRED SPECIAL INSPECTIONS AND TESTS
1118 TABLE 1705A.2.1 REQUIRED SPECIAL INSPECTIONS AND TESTS OF STEEL CONSTRUCTION
1119 TABLE 1705A.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
1120 TABLE 1705A.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
1122 TABLE 1705A.5.3 REQUIRED SPECIAL INSPECTIONS OF MASS TIMBER CONSTRUCTION
1123 TABLE 1705A.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
1124 TABLE 1705A.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705A.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
1126 TABLE 1705A.13.7 REQUIRED INSPECTIONS OF STORAGE RACK SYSTEMS
1129 SECTION 1706A DESIGN STRENGTHS OF MATERIALS
SECTION 1707A ALTERNATIVE TEST PROCEDURE
1130 SECTION 1708A IN-SITU LOAD TESTS
SECTION 1709A PRECONSTRUCTION LOAD TESTS
1133 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18 – SOILS AND FOUNDATIONS
1134 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18 – SOILS AND FOUNDATIONS—continued
1135 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
1139 SECTION 1804 EXCAVATION, GRADING AND FILL
1140 SECTION 1805 DAMPPROOFING AND WATERPROOFING
1141 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
1142 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
1143 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
1144 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
1145 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
1146 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHESa, b, c
1147 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c
1148 EQUATION 18-1
EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
1149 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
1150 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′c OF CONCRETE OR GROUT
1151 TABLE 1808.8.2 MINIMUM CONCRETE COVER
SECTION 1809 SHALLOW FOUNDATIONS
FIGURE 1809.3 STEPPED FOUNDATIONS
1152 TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa, b, c, d, e
1153 SECTION 1810 DEEP FOUNDATIONS
1156 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
1157 EQUATION 18-4
1159 EQUATION 18-5
1165 SECTION 1811 PRESTRESSED ROCK AND SOIL FOUNDATION ANCHORS [OSHPD 1R, 2B & 5]
SECTION 1812 EARTH RETAINING SHORING [OSHPD 1R, 2B & 5]
1169 SECTION 1813 VIBRO STONE COLUMNS FOR GROUND IMPROVEMENT [OSHPD 1R, 2 & 5]
1171 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 18A – SOILS AND FOUNDATIONS
1173 CHAPTER 18A SOILS AND FOUNDATIONS
SECTION 1801A GENERAL
SECTION 1802A DESIGN BASIS
SECTION 1803A GEOTECHNICAL INVESTIGATIONS
1176 SECTION 1804A EXCAVATION, GRADING AND FILL
1177 SECTION 1805A DAMPPROOFING AND WATERPROOFING
1179 SECTION 1806A PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
TABLE 1806A.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807A FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
1180 EQUATION 18A-1
1181 EQUATION 18A-2
EQUATION 18A-3
SECTION 1808A FOUNDATIONS
1182 FIGURE 1808A.7.1 FOUNDATION CLEARANCES FROM SLOPES
1183 TABLE 1808A.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′c OF CONCRETE OR GROUT
TABLE 1808A.8.2 MINIMUM CONCRETE COVER
1184 SECTION 1809A SHALLOW FOUNDATIONS
1185 SECTION 1810A DEEP FOUNDATIONS
1187 TABLE 1810A.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
1191 EQUATION 18A-5
1196 SECTION 1811A PRESTRESSED ROCK AND SOIL FOUNDATION ANCHORS
SECTION 1812A EARTH RETAINING SHORING
1199 SECTION 1813A VIBRO STONE COLUMNS FOR GROUND IMPROVEMENT
1201 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 19 – CONCRETE
1203 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
1205 SECTION 1902 COORDINATION OF TERMINOLOGY
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
1206 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
1209 SECTION 1906 FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907 MINIMUM SLAB PROVISIONS
SECTION 1908 SHOTCRETE
SECTION 1909 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1212 TABLE 21.2.2 STRENGTH REDUCTION FACTOR φ FOR MOMENT,AXIAL FORCE, OR COMBINED MOMENT AND AXIAL FORCE
1213 SECTION 1910 ADDITIONAL REQUIREMENTS FOR SKILLED NURSING FACILITIES, INTERMEDIATE CARE FACILITIES, ACUTE PSYCHIATRIC AND NON-GAC BUILDINGS [OSHPD 1R, 2B & 5]
1214 TABLE 21.2.2 STRENGTH REDUCTION FACTOR φ FOR MOMENT,AXIAL FORCE, OR COMBINED MOMENT AND AXIAL FORCE
SECTION 1911 EXISTING CONCRETE STRUCTURES [OSHPD 1R, 2 & 5]
1217 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 19A – CONCRETE
1219 CHAPTER 19A CONCRETE
SECTION 1901A GENERAL
1220 SECTION 1902A COORDINATION OF TERMINOLOGY
SECTION 1903A SPECIFICATIONS FOR TESTS AND MATERIALS
1221 SECTION 1904A DURABILITY REQUIREMENTS
SECTION 1905A MODIFICATIONS TO ACI 318
1223 TABLE 21.2.2 STRENGTH REDUCTION FACTOR φ FOR MOMENT, AXIAL FORCE, OR COMBINED MOMENT AND AXIAL FORCE
1224 SECTION 1906A FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
SECTION 1907A MINIMUM SLAB PROVISIONS
SECTION 1908A SHOTCRETE
SECTION 1909A RESERVED
SECTION 1910A CONCRETE, REINFORCEMENT AND ANCHOR TESTING
1226 SECTION 1911A EXISTING CONCRETE STRUCTURES
1229 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 20 – ALUMINUM
1231 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
SECTION 2003 TESTING AND INSPECTION
1233 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 21 – MASONRY
1235 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
1236 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
1237 SECTION 2104 CONSTRUCTION
1238 SECTION 2105 QUALITY ASSURANCE
1239 SECTION 2106 SEISMIC DESIGN
1240 SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
TABLE 8.3.4.4 MINIMUM THICKNESS OF MASONRY WALLS1, 2
1241 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
EQUATION 21-2
1242 TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
1243 SECTION 2110 GLASS UNIT MASONRY
1244 SECTION 2111 MASONRY FIREPLACES
1245 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
1246 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
1249 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
1250 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
1251 SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
SECTION 2115 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1254 TABLE 8.3.4.4 MINIMUM THICKNESS OF MASONRY WALLS1, 2
1255 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 21A – MASONRY
1257 CHAPTER 21A MASONRY
SECTION 2101A GENERAL
SECTION 2102A NOTATIONS
SECTION 2103A MASONRY CONSTRUCTION MATERIALS
1258 TABLE 2103A.2.3 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104A CONSTRUCTION
1261 SECTION 2105A QUALITY ASSURANCE
1262 SECTION 2106A SEISMIC DESIGN
1263 SECTION 2107A ALLOWABLE STRESS DESIGN
EQUATION 21A-1
TABLE 8.3.4.4 MINIMUM THICKNESS OF MASONRY WALLS1, 2
1264 SECTION 2108A STRENGTH DESIGN OF MASONRY
SECTION 2109A EMPIRICAL DESIGN OF ADOBE MASONRY
SECTION 2110A GLASS UNIT MASONRY
SECTION 2111A MASONRY FIREPLACES
1266 FIGURE 2111A.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
1267 SECTION 2112A MASONRY HEATERS
SECTION 2113A MASONRY CHIMNEYS
1269 FIGURE 2113A.16 FLUE SIZES FOR MASONRY CHIMNEYS
1271 TABLE 2113A.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113A.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
FIGURE 2113A.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114A DRY-STACK MASONRY
1272 TABLE 2114A.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
1273 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 22 – STEEL
1275 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
1276 SECTION 2205 STRUCTURAL STEEL
1278 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
1279 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
1280 SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
1281 SECTION 2212 ADDITIONAL REQUIREMENTS FOR COMMUNITY COLLEGES [DSA-SS/CC]
1282 SECTION 2213 TESTING AND FIELD VERIFICATION[OSHPD 1R, 2 & 5]
1283 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 22A – STEEL
1285 CHAPTER 22A STEEL
SECTION 2201A GENERAL
SECTION 2202A IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203A PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204A CONNECTIONS
1286 SECTION 2205A STRUCTURAL STEEL
1288 SECTION 2206A COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207A STEEL JOISTS
1289 SECTION 2208A STEEL CABLE STRUCTURES
1290 SECTION 2209A STEEL STORAGE RACKS
SECTION 2210A COLD-FORMED STEEL
SECTION 2211A COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
1291 SECTION 2212A [DSA-SS] LIGHT MODULAR STEEL MOMENT FRAMES FOR PUBLIC ELEMENTARY AND SECONDARY SCHOOLS, AND COMMUNITY COLLEGES
EQUATION 22A-1
1292 SECTION 2213A TESTING AND FIELD VERIFICATION
1293 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 23 – WOOD
1295 CHAPTER 23 WOOD
SECTION 2301 GENERAL
1296 SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
1300 FIGURE 2303.4.1.2 (1) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING ONE ROW OF PITMR
1301 FIGURE 2303.4.1.2(2) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF ONE ROW OF PITMR
1302 FIGURE 2303.4.1.2(3) PITMR AND PITMDB FOR TRUSS WEB MEMBERS REQUIRING TWO ROWS OF PITMR
1303 FIGURE 2303.4.1.2(4) ALTERNATIVE INSTALLATION USING BUCKLING REINFORCEMENT FOR TRUSS WEB MEMBERS IN LIEU OF TWO ROWS OF PITMR
1304 FIGURE 2303.4.1.2(5) PITMR AND PITMDB FOR FLAT PORTION OF TOP CHORD IN A PIGGYBACK ASSEMBLY
1305 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
1306 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa, b, c
1307 TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRA
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
1308 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a(Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS(Plywood structural panels are five-ply, five-layer unless otherwise noted)a
1309 TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKN
1311 TABLE 2304.10.2 FASTENING SCHEDULE
1312 TABLE 2304.10.2—continued FASTENING SCHEDULE
1313 TABLE 2304.10.2—continued FASTENING SCHEDULE
1314 TABLE 2304.10.2—continued FASTENING SCHEDULE
1315 TABLE 2304.10.2—continued FASTENING SCHEDULE
1316 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
1319 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1)en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP(Structural I)a, c
EQUATION 23-2
1320 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
1321 TABLE 2306.1 STANDARDS FOR DESIGN AND CONSTRUCTION OF WOOD ELEMENTS IN STRUCTURES USING ALLOWABLE STRESS DESIGN
TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
1322 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMSUTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
1323 FIGURE 2306.2(1) CASES 1 THROUGH 6 FOR USE WITH TABLE 2306.2(1)
TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OFDOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, g, h
1324 FIGURE 2306.2(2) FASTENER SPACING DIAGRAMS FOR USE WITH TABLE 2306.2(2)
1325 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITHFRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, f, g,
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARDCONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLYa, b, c, d, e
1326 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH ANDPLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
1327 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
1329 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
1330 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
1331 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS(Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
1332 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential sleeping areas, live load = 30 psf, L/Δ = 360)
1333 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential sleeping areas, live load = 30 psf, L/Δ = 360)
1334 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential living areas, live load = 40 psf, L/Δ = 360)
1335 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES(Residential living areas, live load = 40 psf, L/Δ = 360)
1336 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
1337 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
1338 TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
1339 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
1340 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
1341 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
1342 TABLE 2308.6.1 WALL BRACING REQUIREMENTSa
1343 TABLE 2308.6.3(1) BRACING METHODS
1344 TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb(Not exposed to the weather, strength axis parallel or perpendicular to studs except as indicated)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING(Not exposed to the weather, long dimension of the panel parallel or perpendicular to studs)
1345 TABLE 2308.6.3(5) HARDBOARD SIDING
1346 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
1347 FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
1348 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
1350 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
1351 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
1353 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)a, b, c, e, f, g, h
1354 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
1355 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
1356 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
1357 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES(Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
1358 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
1359 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
1360 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
1361 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
1362 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
1363 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
1364 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
1365 TABLE 2308.7.2(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
1366 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
1367 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
1368 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
1369 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES(Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
TABLE 2308.7.2(7) RAFTER SPAN ADJUSTMENT FACTOR
1370 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSi
1371 TABLE 2308.7.3.1(1) HEEL JOINT CONNECTION ADJUSTMENT FACTORS
TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1372 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
1373 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 24 – GLASS AND GLAZING
1375 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
1376 TABLE 2403.2.1 MINIMUM GLAZING REQUIREMENTS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
1377 EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
1378 EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
1379 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
1380 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
1381 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
1382 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS,ELEVATOR HOISTWAYS AND ELEVATOR CARS
SECTION 2410 [DSA-SS, DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5]STRUCTURAL SEALANT GLAZING (SSG)
1384 SECTION 2411 [OSHPD 1, 1R, 2, 4 & 5]THERMAL BARRIERS IN ALUMINUM MULLION SYSTEMS
1387 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 25 – GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
1389 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
1390 SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
1391 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
1392 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
1393 TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER(STUCCO)
1394 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
1395 SECTION 2512 EXTERIOR PLASTER
TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
1396 SECTION 2514 REINFORCED GYPSUM CONCRETE
1397 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 26 – PLASTIC
1399 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
1403 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
1404 [BS] TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECTATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
1405 [BS] TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
1406 [BS]TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
[BS]TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa, b
1407 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
1408 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
1409 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
1410 TABLE 2609.4 AREA LIMITATIONS FORLIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
1411 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
1412 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
1413 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 27 – ELECTRICAL
1415 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
1417 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 28 – MECHANICAL SYSTEMS
1419 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
1421 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
1422 [P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1423 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1424 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
1426 [P] SECTION 2903 INSTALLATION OF FIXTURES
1427 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 30 – ELEVATORS AND CONVEYING SYSTEMS
1429 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
1431 SECTION 3003 EMERGENCY OPERATIONS
1432 SECTION 3004 CONVEYING SYSTEMS
SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
1433 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
1434 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
1435 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
1437 SECTION 3009 SPECIAL REQUIREMENTS FOR ELEVATORS IN HOSPITALS
1439 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31 – SPECIAL CONSTRUCTION
1441 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
1442 SECTION 3103 TEMPORARY STRUCTURES
1443 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
1444 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
1445 SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
1447 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
1448 SECTION 3112 PATIO COVERS
SECTION 3113 RELOCATABLE BUILDINGS
1449 SECTION 3114 PUBLIC USE RESTROOM BUILDINGS IN FLOOD HAZARD AREAS
1450 SECTION 3115 INTERMODAL SHIPPING CONTAINERS
1452 TABLE 3115.8.5.3 ALLOWABLE SHEAR VALUES FOR INTERMODAL SHIPPING CONTAINER CORRUGATED STEEL WALLS FOR WIND OR SEISMIC LOADING
1453 FIGURE 3115.8.5.3(1) BRACING UNIT DISTRIBUTION—MAXIMUM LINEAR LENGTH
FIGURE 3115.8.5.3(2) BRACING UNIT DISTRIBUTION—MINIMUM LINEAR LENGTH
1454 FIGURE 3115.8.5.3(3) BRACING UNIT DISTRIBUTION—BOUNDARY ELEMENTS
FIGURE 3115.8.5.3(4) BRACING UNIT DISTRIBUTION—PENETRATION LIMITATIONS
1455 CHAPTER 31A SYSTEMS FOR WINDOW CLEANING OR EXTERIOR BUILDING MAINTENANCE
1457 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31B – PUBLIC POOLS
1459 CHAPTER 31B [DPH] PUBLIC POOLS
DIVISION I – GENERAL
SECTION 3101B SCOPE
SECTION 3102B DEFINITIONS
1460 SECTION 3103B PLAN REVIEW
1461 SECTION 3104B CONSTRUCTION
SECTION 3105B PLAN COMPLIANCE INSPECTIONS
SECTION 3106B SPECIAL REQUIREMENTS FOR SPRAY GROUNDS
1462 SECTION 3107B ALTERNATIVE EQUIPMENT, MATERIALS AND METHODS OF CONSTRUCTION
SECTION 3108B POOL CONSTRUCTION
SECTION 3109B POOL GEOMETRY
SECTION 3110B PERMANENT MARKINGS
1463 SECTION 3111B STEPS, RECESSED STEPS, LADDERS AND STAIRS
1464 SECTION 3112B HANDHOLDS
SECTION 3113B DIVING BOARDS AND PLATFORMS
SECTION 3114B POOL DECKS
SECTION 3115B POOL LIGHTING
1465 SECTION 3116B DRESSING, SHOWER AND TOILET FACILITIES
SECTION 3117B DRINKING FOUNTAINS
SECTION 3118B HOSE BIBBS
SECTION 3119B POOL ENCLOSURE
1466 SECTION 3120B REQUIRED SIGNS
1467 SECTION 3121B INDOOR POOL VENTILATION
SECTION 3122B POOL EQUIPMENT ENCLOSURE
SECTION 3123B GENERAL REQUIREMENTS
SECTION 3124B TURNOVER TIME
1468 SECTION 3125B RECIRCULATION PIPING SYSTEM AND COMPONENTS
SECTION 3126B RECIRCULATION PUMP CAPACITY
SECTION 3127B WATER SUPPLY INLETS
SECTION 3128B FILTERS (ALL TYPES)
SECTION 3129B RAPID SAND PRESSURE FILTERS
SECTION 3130B DIATOMACEOUS EARTH FILTERS
1469 SECTION 3131B HIGH-RATE SAND FILTERS
SECTION 3132B CARTRIDGE FILTERS
SECTION 3133B CHEMICAL FEEDERS
SECTION 3134B DISINFECTANT FEEDERS
1470 FIGURE 31B-1 DEPTHS AND CLEARANCES FOR POOLS WITH DIVING BOARDS GREATER THAN 30 INCHES (762 mm) ABOVE THE WATER LINE
TABLE 31B-1
1471 FIGURE 31B-2 DEPTHS AND CLEARANCES FOR POOLS WITH DIVING BOARDS 30 INCHES (762 MM) OR LESS ABOVE THE WATER LINE
TABLE 31B-2
1472 FIGURE 31B-3 DEPTHS AND CLEARANCES FOR POOLS WITHOUT DIVING BOARDS
TABLE 31B-3A POOLS WITH MAXIMUM WATER DEPTH ≤ 6’0″
TABLE 31B-3B POOLS WITH MAXIMUM WATER DEPTH > 6’0″
1473 SECTION 3135B GAS CHLORINATION EQUIPMENT ROOM
SECTION 3136B POOL SKIMMING SYSTEMS
1474 SECTION 3137B POOL FITTINGS
SECTION 3138B SPA POOL SPECIAL REQUIREMENTS
SECTION 3139B SOLAR HEATING INSTALLATIONS
SECTION 3140B CLEANING SYSTEMS
1475 SECTION 3141B WASTEWATER DISPOSAL
SECTION 3142B RESERVED
SECTION 3143B RESERVED
SECTION 3144B RESERVED
SECTION 3145B RESERVED
SECTION 3146B
RESERVED
SECTION 3147B RESERVED
SECTION 3148B RESERVED
SECTION 3149B RESERVED
SECTION 3150B RESERVED
SECTION 3151B RESERVED
SECTION 3152B RESERVED
SECTION 3153B RESERVED
SECTION 3154B RESERVED
SECTION 3155B RESERVED
SECTION 3156B RESERVED
SECTION 3157B RESERVED
SECTION 3158B RESERVED
SECTION 3159B RESERVED
DIVISION II – PUBLIC SWIMMING POOLS
SECTION 3160B GROUND FAULT CIRCUIT INTERRUPTERS
1476 SECTION 3161B WADING POOLS
SECTION 3162 BANTI-ENTRAPMENT DEVICES AND SYSTEMS
1479 FIGURE 31B-4 PERPENDICULAR FENCING DIMENSIONS ON SLOPING GROUND
FIGURE 31B-5 EFFECTIVE FENCING HEIGHT
1480 FIGURE 31B-6 DEPTHS AND DIMENSIONS FOR SPA POOLS
1481 TABLE 31B-6
FIGURE 31B-7 STAIR AND HANDRAIL DIMENSIONS
1482 TABLE 31B-7
FIGURE 31B-8 DEPTH MARKER LOCATIONS
1483 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31C – RADIATION
1485 CHAPTER 31C [DPH] RADIATION
SECTION 3101C SCOPE
SECTION 3102C RADIATION SHIELDING BARRIERS
SECTION 3103C MEDICAL RADIOGRAPHIC AND PHOTOFLUOROGRAPHIC INSTALLATIONS
SECTION 3104C MEDICAL THERAPEUTIC X-RAY INSTALLATIONS
1487 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31D – FOOD ESTABLISHMENTS
1489 CHAPTER 31D [DPH] FOOD ESTABLISHMENTS
SECTION 3101D SCOPE
SECTION 3102D DEFINITION
SECTION 3103D BUILDINGS AND STRUCTURES
1491 CHAPTER 31E RESERVED
1493 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 31F – MARINE OIL TERMINALS
1495 CHAPTER 31F [SLC] MARINE OIL TERMINALS
SECTION 3101F [SLC] INTRODUCTION
1496 TABLE 31F-1-1 MOT OIL SPILL EXPOSURE CLASSIFICATION
1498 SECTION 3102F AUDIT AND INSPECTION
TABLE 31F-2-1 MAXIMUM INTERVAL BETWEEN UNDERWATER INSPECTIONS (YEARS)1
1501 TABLE 31F-2-2 UNDERWATER INSPECTION LEVELS OF EFFORT [2.2]
TABLE 31F-2-3 SCOPE OF UNDERWATER INSPECTION [2.2]
1504 TABLE 31F-2-4 ASSESSMENT RATINGS
TABLE 31F-2-5 COMPONENT DEFICIENCY REMEDIAL ACTION PRIORITIES (RAP)
1505 TABLE 31F-2-6 FOLLOW-UP ACTIONS [2.2]
1508 TABLE 31F-2-7A
TABLE 31F-2-7B
1509 TABLE 31F-2-7C
1510 TABLE 31F-2-8
TABLE 31F-2-9 POST-EVENT RATINGS AND REMEDIAL ACTIONS [2.2]
1511 FIGURE 31F-2-1
1512 SECTION 3103F STRUCTURAL LOADING CRITERIA
TABLE 31F-3-1 UNIT WEIGHTS
TABLE 31F-3-2 EQUIPMENT AND PIPING AREA LOADS
1513 EQUATION 3-1
EQUATION 3-2
EQUATION 3-3
EQUATION 3-4
EQUATION 3-5
EQUATION 3-6
EQUATION 3-7
1514 TABLE 31F-3-3 VALUES OF Fa
TABLE 31F-3-4 VALUES OF Fv
1515 EQUATION 3-8
EQUATION 3-9
EQUATION 3-10
TABLE 31F-3-5 VALUES OF BS AND B1 [3.2]
1516 EQUATION 3-11
EQUATION 3-12
EQUATION 3-13
1517 FIGURE 31F-3-1 WIND SPEED CONVERSION FACTOR [3.5]
EQUATION 3-14
1518 FIGURE 31F-3-2 CURRENT VELOCITY CORRECTION FACTOR (p. 23 [3.6])
1519 TABLE 31F-3-6 TSUNAMI RUN-UP VALUES (ft) AND CURRENT SPEEDS (ft/sec)IN THE SAN FRANCISCO BAY AREA (AFTER [3.16])
EQUATION 3-15
EQUATION 3-16
EQUATION 3-17
EQUATION 3-18
1520 EQUATION 3-19
TABLE 31F-3-7 BERTHING VELOCITY Vn (NORMAL TO BERTH)1
EQUATION 3-20
1521 TABLE 31F-3-8 SITE CONDITIONS
TABLE 31F-3-9 BERTHING ANGLE
1522 TABLE 31F-3-10 LRFD LOAD FACTORS FOR LOAD COMBINATIONS [3.18]
TABLE 31F-3-11 SERVICE OR ASD LOAD FACTORS FOR LOAD COMBINATIONS [3.18]
1525 SECTION 3104F SEISMIC ANALYSIS AND STRUCTURAL PERFORMANCE
FIGURE 31F-4-1 DEFINITION OF IRREGULAR MOT
1526 TABLE 31F-4-1 SEISMIC PERFORMANCE CRITERIA1, 2
TABLE 31F-4-2 MINIMUM REQUIRED ANALYTICAL PROCEDURES
FIGURE 31F-4-2 PILE-DECK CONNECTION MODELING FOR PRESTRESSED CONCRETE PILE (ADAPTED FROM [4.2])
1527 FIGURE 31F-4-3 SIMPLIFIED SINGLE PILE MODEL OF A TIMBER PILE SUPPORTED STRUCTURE
EQUATION 4-1
FIGURE 31F-4-4 IDEALIZATION OF PUSHOVERCURVE (ADAPTED FROM [4.3])
EQUATION 4-2
EQUATION 4-3
1528 EQUATION 4-4
EQUATION 4-5
EQUATION 4-6
EQUATION 4-7
EQUATION 4-8
EQUATION 4-9
EQUATION 4-10
EQUATION 4-11
1529 EQUATION 4-12
EQUATION 4-13
EQUATION 4-14
EQUATION 4-15
FIGURE 31F-4-5 EFFECTIVE STIFFNESS FOR SUBSTITUTE STRUCTURE METHOD
FIGURE 31F-4-6 STIFFNESS FOR LINEAR MODAL ANALYSIS
1530 EQUATION 4-16
EQUATION 4-17
EQUATION 4-18
EQUATION 4-19
EQUATION 4-20
EQUATION 4-21
FIGURE 31F-4-8P-Δ EFFECT
FIGURE 31F-4-7 PLAN VIEW OF WHARF SEGMENT UNDER X AND Y SEISMIC EXCITATIONS
1531 EQUATION 4-22
1532 EQUATION 4-23
1533 EQUATION 4-24
EQUATION 4-25
TABLE 31F-4-3 AMPLIFICATION FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
FIGURE 31F-4-9 AMPLIFICATION FACTOR, ap [4.10]
TABLE 31F-4-4 IMPORTANCE FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
TABLE 31F-4-5 RESPONSE MODIFICATION FACTORS FOR NONSTRUCTURAL COMPONENTS AND NONBUILDING STRUCTURES
1534 EQUATION 4-26
1536 SECTION 3105F MOORING AND BERTHING ANALYSIS AND DESIGN
FIGURE 31F-5-1 TYPICAL PIER AND WHARF CONFIGURATIONS
1537 FIGURE 31F-5-2 HORIZONTAL LINE ANGLES [5.4]
FIGURE 31F-5-3 VERTICAL LINE ANGLES [5.4]
1538 EQUATION 5-1
FIGURE 31F-5-4 PASSING VESSEL
1539 FIGURE 31F-5-5 BERTHING ENERGY CAPACITY
TABLE 31F-5-1 CONTACT LENGTH
TABLE 31F-5-2 COEFFICIENT OF FRICTION
EQUATION 5-3
1540 TABLE 31F-5-3 SAFETY FACTORS FOR ROPES [5.4]
EQUATION 5-4
TABLE 31F-5-4 ALLOWABLE WORKING LOADS
1542 SECTION 3106F GEOTECHNICAL HAZARDS AND FOUNDATIONS
TABLE 31F-6-1 SITE CLASSES
1544 FIGURE 31F-6-1 AXIAL SOIL SPRINGS [6.8]
1545 FIGURE 31F-6-2 SLIDING LAYER MODEL [6.8]
1547 SECTION 3107F STRUCTURAL ANALYSIS AND DESIGN OF COMPONENTS
EQUATION 7-1A
EQUATION 7-1B
EQUATION 7-1C
EQUATION 7-2A
EQUATION 7-2B
EQUATION 7-2C
EQUATION 7-3A
EQUATION 7-3B
EQUATION 7-3C
1548 TABLE 31F-7-1 COMPRESSIVE STRENGTH OF STRUCTURAL CONCRETE (psi)1
TABLE 31F-7-2 TENSILE AND YIELD PROPERTIES OF REINFORCING BARS FOR VARIOUS ASTM SPECIFICATIONS AND PERIODS(after Table 6-2 of [7.3])
1549 TABLE 31F-7-3 EFFECTIVE ELASTIC STIFFNESS
FIGURE 31F-7-1 STRESS-STRAIN CURVES FOR CONFINED AND UNCONFINED CONCRETE [7.1]
FIGURE 31F-7-2 STRESS-STRAIN CURVE FOR MILD REINFORCING STEEL OR STRUCTURAL STEEL [7.1]
1550 FIGURE 31F-7-3 STRESS-STRAIN CURVE FOR PRESTRESSED STEEL [7.4]
EQUATION 7-4
EQUATION 7-5
EQUATION 7-6
EQUATION 7-7
TABLE 31F-7-4 PLASTIC HINGE LENGTH FOR PRESTRESSED CONCRETE PILES [7.5]
EQUATION 7-8
EQUATION 7-9
1551 TABLE 31F-7-5 LIMITS OF STRAIN
EQUATION 7-10
FIGURE 31F-7-4 METHOD A − MOMENT CURVATURE ANALYSIS
FIGURE 31F-7-5 METHOD B – MOMENT CURVATURE ANALYSIS [7.6]
EQUATION 7-11
EQUATION 7-12
1552 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
EQUATION 7-16
EQUATION 7-17
EQUATION 7-18
FIGURE 31F-7-6 CONCRETE SHEAR MECHANISM(from Fig. 3-30 of [7.2])
1553 FIGURE 31F-7-7 TRANSVERSE SHEAR MECHANISM
FIGURE 31F-7-8 AXIAL FORCE SHEAR MECHANISM
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
1554 TABLE 31F-7-7 STRUCTURAL STEEL STRAIN LIMITS, εu
EQUATION 7-22
EQUATION 7-23
FIGURE 31F-7-9 DEVELOPMENT LENGTH
EQUATION 7-24
EQUATION 7-25
FIGURE 31F-7-10 DEGRADATION OF EFFECTIVE PRINCIPAL TENSION STRENGTH WITH JOINT SHEAR STRAIN (rotation) [7.1, pg. 564]
EQUATION 7-26
EQUATION 7-27
1555 FIGURE 31F-7-11 REDUCED PILE MOMENT CAPACITY
EQUATION 7-28
EQUATION 7-29
EQUATION 7-30
EQUATION 7-31
EQUATION 7-32
FIGURE 31F-7-12 JOINT ROTATION
FIGURE 31F-7-13 EQUIVALENT PILE CURVATURE
1556 EQUATION 7-33
EQUATION 7-34
FIGURE 31F-7-14 PUSHOVER CURVE FOR ORDINARY BATTER PILES
1558 FIGURE 31F-7-15 ASSUMED IN-GROUND FIXITY
TABLE 31F-7-8 DISTANCE BELOW GROUND TO POINT OF FIXITY
EQUATION 7-36
EQUATION 7-37
EQUATION 7-38
EQUATION 7-39
TABLE 31F-7-9 LIMITING STRAIN VALUES FOR TIMBER
EQUATION 7-40
EQUATION 7-41
EQUATION 7-42
1562 SECTION 3108F FIRE PREVENTION, DETECTION AND SUPPRESSION
1563 TABLE 31F-8-1 CARGO LIQUID VOLATILITY RATINGS
TABLE 31F-8-2 FIRE HAZARD CLASSIFICATIONS
1564 TABLE 31F-8-3 MINIMUM FIRE SUPPRESSION PROVISIONS (N/E)
1566 SECTION 3109F PIPING AND PIPELINES
1567 TABLE 31F-9-1 COEFFICIENTS OF STATIC FRICTION
1569 SECTION 3110F MECHANICAL AND ELECTRICAL EQUIPMENT
1572 SECTION 3111F ELECTRICAL SYSTEMS
1575 SECTION 3112F REQUIREMENTS SPECIFIC TO MARINE TERMINALS THAT TRANSFER LNG
1577 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 32 – ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
1579 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
1581 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 33 – SAFEGUARDS DURING CONSTRUCTION
1583 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
1584 SECTION 3304 SITE WORK
SECTION 3305 TOILET FACILITIES DURING CONSTRUCTION
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
1585 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
1586 SECTION 3308 TEMPORARY USE OF STREETS,ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
1587 SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
1588 SECTION 3314 FIRE WATCH DURING CONSTRUCTION
1589 CHAPTER 34 RESERVED
1591 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS
1592 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS—continued
1593 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS—continued
1594 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 35 – REFERENCED STANDARDS—continued
1595 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
1596 ACI
AISC
1597 AISI
ALI
AMCA
ANSI
1598 APA
1599 ASABE
ASCE/SEI
1600 ASHRAE
ASME
ASSP
ASTM
1614 AWC
AWCI
AWPA
AWS
1615 BHMA
CEN
CPA
CPSC
1616 CSA
CSSB
DASMA
DHA
DOC
1617 DOL
DOTn
EN
FEMA
FM
1618 GA
ICC
1619 ISO
MHI
1620 NAAMM
NCMA
NEHRP
NFPA
1632 PCI
1633 PTI
RMI
SBCA
SDI
SFM
1634 SJI
SPRI
SRCC
TIA
1635 TMS
TPI
UBC
UL
1639 ULC
USC
WCLIB
WDMA
WRI
1641 CHAPTER 61 SPECIAL HAZARD AREAS
SECTION 6101 IMPACT HAZARD GLAZING IN EXISTING BUILDINGS
SECTION 6102 RUBBISH ROOMS
SECTION 6103 SHAFTS, PITS AND SIMILAR EXCAVATION –MISDEMEANOR
SECTION 6104 FIRE DISTRICTS
SECTION 6105 SEPARATION FROM OIL WELLS
1642 SECTION 6106 RESERVED
SECTION 6107 RESERVED
SECTION 6108 RESERVED
SECTION 6109 SWIMMING POOLS AND OTHER BODIES OF WATER – PROTECTIVE DEVICES REQUIRED
1643 CHAPTER 62 SIGNS
SECTION 6201 GENERAL PROVISIONS
1644 SECTION 6202 DEFINITIONS
SECTION 6203 LOCATION
SECTION 6204 IDENTIFICATION
1645 SECTION 6205 DESIGN AND CONSTRUCTION
1646 SECTION 6206 ELECTRICAL
SECTION 6207 COMBUSTIBLE MATERIALS
SECTION 6208 ANIMATED DEVICES
SECTION 6209 GROUND SIGNS
SECTION 6210 ROOF SIGNS
1647 SECTION 6211 WALL SIGNS
SECTION 6212 PROJECTING SIGNS
SECTION 6213 MARQUEE SIGNS
1648 SECTION 6215 REFERENCED STANDARDS
SECTION 6216 EXISTING SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
1649 CHAPTER 63 ADDITIONAL PROVISIONS FOR SPECIFIC USES
SECTION 6301 GENERAL
SECTION 6302 FOOD ESTABLISHMENT
1650 SECTION 6303 SERVICE STATIONS
SECTION 6304 RESIDENTIAL USES
SECTION 6305 PARKING GARAGES SERVING RESIDENTIAL USES
SECTION 6306 ANTI-GRAFFITI FINISH TO EXTERIOR WALLS
SECTION 6307 SHOWER AND LOCKER FACILITIES
1653 CHAPTER 67 SECURITY PROVISIONS
SECTION 6701 PURPOSE
SECTION 6702 GENERAL
SECTION 6703 LIMITATIONS
SECTION 6704 ALTERNATIVE SECURITY PROVISIONS
SECTION 6705 DEFINITIONS
1654 SECTION 6706 ENTRY VISION
SECTION 6707 APPURTENANT ACCESS
SECTION 6708 DOORS – GENERAL
SECTION 6709 SWINGING DOORS
1655 SECTION 6710 SLIDING GLASS DOORS
SECTION 6711 OVERHEAD AND SLIDING DOORS
SECTION 6712 METAL ACCORDION-GRATE OR GRILLE-TYPE DOORS
SECTION 6713 GLAZED OPENING – GENERAL
SECTION 6714 GLAZING
SECTION 6715 WINDOWS
1656 SECTION 6716 OPENINGS OTHER THAN DOORS OR GLAZED OPENINGS
SECTION 6717 TESTS – GENERAL
1657 CHAPTER 70 GRADING, EXCAVATIONS AND FILLS
SECTION 7001 PURPOSE
SECTION 7002 SCOPE
SECTION 7003 DEFINITIONS
1658 SECTION 7004 GRADING DESIGNATION
SECTION 7005 GENERAL REQUIREMENTS
1659 SECTION 7006 CONDITIONS PRECEDENT TO ISSUING A GRADING PERMIT
1663 SECTION 7007 SAFETY PRECAUTIONS DURING GRADING
SECTION 7008 PROFESSIONAL INSPECTION AND CERTIFICATION FOR ENGINEERED GRADING
1664 SECTION 7009 PROFESSIONAL INSPECTION FOR REGULAR GRADING
1665 SECTION 7010 EXCAVATIONS
SECTION 7011 FILLS
1666 SECTION 7012 PLANTING AND IRRIGATION OF CUT AND FILL SLOPES IN HILLSIDE AREAS
1667 SECTION 7013 EROSION CONTROL AND DRAINAGE DEVICES
1668 SECTION 7014 CONSTRUCTION REQUIREMENTS AND LIMITATIONS
SECTION 7015 BUTTRESS FILLS
1669 SECTION 7016 AREAS SUBJECTED TO SLIDES AND UNSTABLE SOIL
1671 INTERCEPTOR TERRACE FIGURE A
DIVERTER TERRACEF OR TOP OF CUT SLOPES/ OR FILL SLOPES FIGURE B
BERM DETAIL FIGURE C
1672 20-FOOT HORIZONTAL BENCH FIGURE D
FIGURE E
1673 DRAINAGE DISPERSAL WALL FIGURE F
1674 PLAN VIEW OUTLET STRUCTURE FIGURE G
1675 SECTION A-A
SECTION B-B
SECTION C-C
SECTION D-D
GRATING FASTENING DETAIL H
1676 INLET STRUCTURE SECTION Y-Y
1677 CHAPTER 71 METHANE SEEPAGE REGULATIONS
SECTION 7101 PURPOSE
SECTION 7102 DEFINITIONS
1678 SECTION 7103 GENERAL METHANE MITIGATION REQUIREMENTS
SECTION 7104 GENERAL METHANE REQUIREMENTS
1680 SECTION 7105 EXISTING BUILDINGS
SECTION 7106 TESTING, MAINTENANCE AND SERVICE OF GAS-DETECTION AND MECHANICALVENTILATION SYSTEMS
SECTION 7107 EMERGENCY PROCEDURES
SECTION 7108 APPLICATION OF METHANE SEEPAGE REGULATIONS TO LOCATIONS OR AREAS OUTSIDE THE METHANE ZONE AND METHANE BUFFER ZONE BOUNDARIES
SECTION 7109 ADDITIONAL REMEDIAL MEASURES
1681 TABLE 71 MINIMUM METHANE MITIGATION REQUIREMENTS
1683 CHAPTER 72 FIRE DISTRICT REGULATIONS
SECTION 7200 PURPOSE
SECTION 7201 GENERAL
1685 SECTION 7202 ADDITIONS TO BUILDINGS
SECTION 7203 GENERAL REQUIREMENTS
SECTION 7204 SPECIAL REQUIREMENTS FOR FIRE DISTRICT NUMBER 1
1686 SECTION 7205 PROVISIONAL STRUCTURES
SECTION 7206 SPECIAL REQUIREMENTS FOR FIRE DISTRICT NUMBER 2 (DELETED)
SECTION 7207 SPECIAL REQUIREMENTS FOR THE VERY HIGH FIRE HAZARD SEVERITY ZONE
SECTION 7208 PROHIBITED VEHICLES
1687 CHAPTER 81 MAINTENANCE OF EXISTING BUILDINGS AND STRUCTURES
SECTION 8101 GENERAL PROVISIONS
SECTION 8102 ENFORCEMENT
SECTION 8103 EXISTING BUILDING RIGHTS
SECTION 8104 BASIC MAINTENANCE AND REPAIR OF EXISTING BUILDINGS AND PREMISES
1688 SECTION 8105 ILLEGAL BUILDINGS, CONSTRUCTION AND USE
1689 SECTION 8106 FIRE DISTRICT REQUIREMENTS
SECTION 8107 RESERVED
SECTION 8108 NUISANCES, HAZARDOUS BUILDINGS AND SUBSTANDARD RESIDENTIAL BUILDINGS
1690 SECTION 8109 RELOCATED BUILDINGS
SECTION 8110 UNREINFORCED MASONRY BEARING WALL BUILDINGS
SECTION 8111 RESIDENTIAL HEATING
SECTION 8112 RESIDENTIAL PLUMBING
SECTION 8113 ROD BRACING SYSTEMS
SECTION 8114 PARAPETS AND APPENDAGES
SECTION 8115 SANDBLASTING
1691 SECTION 8116 SPECIAL PROVISIONS FOR LIGHT-HOUSEKEEPING ROOMS
SECTION 8117 FIRE WATCH
SECTION 8118 POOL WATER CLARITY
1692 SECTION 8119 HISTORICAL BUILDINGS AND STRUCTURES
1695 CHAPTER 82 CHANGE OF OCCUPANCY, USE AND RATING CLASSIFICATION
SECTION 8201 GENERAL
SECTION 8202 CHANGE OF RATING CLASSIFICATION
SECTION 8203 CHANGE OF OCCUPANCY GROUPOR GROUP DIVISION
SECTION 8204 CHANGE OF USE
SECTION 8205 CERTIFICATE OF BUILDING COMPLIANCE
TABLE 82-A CERTIFICATE OF BUILDING COMPLIANCE INSPECTION FEE
1697 CHAPTER 83 RELOCATION PERMIT
SECTION 8301 GENERAL APPLICATION
SECTION 8302 PERMITS REQUIRED –GENERAL CONSIDERATIONS
SECTION 8303 PERMIT APPLICATION –PLANS AND SPECIFICATIONS
1698 SECTION 8304 SPECIAL CONDITIONS UNDER WHICHA PERMIT WILL NOT BE ISSUED
SECTION 8305 GUARANTEE OF COMPLETION REQUIRED
1699 SECTION 8306 TERMS OF PERMIT
SECTION 8307 DEFAULT IN PERFORMANCE OF CONDITIONS OR TERMS OF PERMITS – FAILURE TO COMPLETE
SECTION 8308 PERMIT FEES
1700 SECTION 8309 ENTRY UPON PREMISES
TABLE-A BASIC RELOCATION APPLICATION FEE SCHEDULE
1701 CHAPTER 85 ALTERNATIVE BUILDING STANDARDS FOR JOINT LIVING AND WORK QUARTERS
SECTION 8501 GENERAL
1702 SECTION 8502 ALTERNATIVE STANDARDS
1707 CHAPTER 86 SPECIAL PROVISIONS FOR EXISTING BUILDINGS
SECTION 8601 GENERAL
SECTION 8602 GROUP E OCCUPANCIES
1708 SECTION 8603 FIRE PROTECTION – WARNING SYSTEM
SECTION 8604 FIRE SAFETY STANDARDS
1713 SECTION 8605 EMERGENCY HOMELESS SHELTERS
1714 SECTION 8606 EMERGENCY LIGHTING STANDARDS FOR EXISTING RESIDENTIAL BUILDINGS, GROUP R, DIVISION 1 OCCUPANCIES
1715 SECTION 8607 TENANT SAFETY FOR APARTMENT HOUSES,EXCEPT FOR RESIDENTIAL CONDOMINIUMS
1717 CHAPTER 88 EARTHQUAKE HAZARD REDUCTION IN EXISTING BUILDINGS
SECTION 8801 PURPOSE
SECTION 8802 SCOPE
SECTION 8803 DEFINITIONS
SECTION 8804 RATING CLASSIFICATIONS
1718 SECTION 8805 GENERAL REQUIREMENTS
SECTION 8806 ADMINISTRATION
1719 SECTION 8807 HISTORICAL BUILDINGS
SECTION 8808 ANALYSIS AND DESIGN
FORMULA 8-1
FORMULA 8-2
1720 SECTION 8809 MATERIALS OF CONSTRUCTION
1722 SECTION 8810 INFORMATION REQUIRED ON PLANS
1723 SECTION 8811 DESIGN CHECK – COMPATIBILITY OF ROOF DIAPHRAGM STIFFNESS TO UNREINFORCEDMASONRY WALL OUT-OF-PLANE STABILITY
1724 FORMULA 11-3
FORMULA 11-4
SECTION 8812 VIOLATIONS
SECTION 8813 SPECIAL REQUIREMENTS FOR VACANT BUILDINGS
1725 DEMAND-CAPACITY RATIO, 0.33 Wd /(2vuD) OR 0.33 Wd /(2vuD + ?Vc) ACCEPTABLE SPAN FOR DIAPHRAGMS(BASED ON DISPLACEMENT CONTROL CONCEPTS)FIGURE 88
1726 TABLE 88-A RATING CLASSIFICATIONS
TABLE 88-B TIME LIMITS FOR COMPLIANCE
TABLE 88-C SERVICE PROVISIONS AND EXTENDED TIME PROVISIONS**
TABLE 88-D HORIZONTAL FORCE FACTORS BASED ON RATING CLASSIFICATION
TABLE 88-E HORIZONTAL FORCE FACTORS “IS” FOR PARTS OR PORTIONS OF STRUCTURES
1727 TABLE 88-F HORIZONTAL FORCE FACTOR “CP” FOR PARTS OR PORTIONS OF BUILDINGS OR OTHER STRUCTURES1
TABLE 88-G ALLOWABLE VALUE OF HEIGHT-TO-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS WITH MINIMUM QUALITY MORTAR1, 2
1728 TABLE 88-H VALUES FOR EXISTING MATERIALS
TABLE 88-I ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
1729 TABLE 88-J ALLOWABLE SHEAR STRESS FOR TESTED UNREINFORCED MASONRY WALLS
TABLE 88-K VALUES FOR EXISTING MATERIALS
TABLE 88-L ALLOWABLE VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
TABLE 88-M ALLOWABLE SHEAR ON BOLTS
1731 CHAPTER 89 ABATEMENT OF BUILDINGS, STRUCTURES, PREMISES AND PORTIONS THEREOF WHICH CONSTITUTE A NUISANCE OR ARE HAZARDOUS, OR SUBSTANDARD
SECTION 8901 GENERAL
SECTION 8902 DEFINITIONS
1734 SECTION 8903 ABATEMENT PROCEDURES
1737 SECTION 8904 SPECIAL PROVISIONS FOR VACANT PROPERTY GRAFFITI REMOVAL
1739 SECTION 8905 SPECIAL PROVISIONS FOR VACATING,BARRICADING, REMOVING OR DEMOLISHING BUILDINGS OR STRUCTURES WITHOUT NOTICE
SECTION 8906 PAYMENT AND RECOVERY OF REPAIR AND DEMOLITION FUNDS
1740 SECTION 8907 ABATEMENT OF PUBLIC NUISANCE CONDITIONS RELATED TO A DECLARED LOCAL EMERGENCY
1741 SECTION 8908 SPECIAL PROVISIONS FOR THE REPAIR OF WELDED STEEL MOMENT FRAME BUILDINGS LOCATED IN HIGH EARTHQUAKE DAMAGED AREAS
1743 CHAPTER 91 EARTHQUAKE HAZARD REDUCTION IN EXISTING TILT-UP CONCRETE WALL BUILDINGS
SECTION 9101 PURPOSE
SECTION 9102 SCOPE
SECTION 9103 DEFINITIONS
SECTION 9104 RATING CLASSIFICATIONS
SECTION 9105 GENERAL REQUIREMENTS
1744 SECTION 9106 ADMINISTRATION
SECTION 9107 HISTORICAL BUILDINGS
SECTION 9108 ANALYSIS AND DESIGN
1746 SECTION 9109 MATERIALS OF CONSTRUCTION
SECTION 9110 INFORMATION REQUIRED ON PLANS
SECTION 9111 REQUIRED BUILDING MAINTENANCE
SECTION 9112 VIOLATIONS – PENALTIES FOR DISREGARDING DEPARTMENT ORDERS
1747 TABLE 91-A RATING CLASSIFICATIONS
TABLE 91-B TIME LIMITS FOR COMPLIANCE
TABLE 91-C SERVICE PRIORITIES
1749 CHAPTER 92 VOLUNTARY EARTHQUAKE HAZARD REDUCTION IN EXISTING WOOD FRAME RESIDENTIAL BUILDINGS WITH WEAK CRIPPLEWALLS AND UNBOLTED SILL PLATES
SECTION 9201 GENERAL
FORMULA 92-1
SECTION 9202 DEFINITIONS
1750 SECTION 9203 STRUCTURAL WEAKNESSES
SECTION 9204 STRENGTHENING REQUIREMENTS
1753 SECTION 9205 QUALITY CONTROL
TABLE 92-A SILL PLATE ANCHORAGE AND CRIPPLE WALL BRACING1,2,3
1755 CHAPTER 93 MANDATORY EARTHQUAKE HAZARD REDUCTION IN EXISTING WOOD-FRAME BUILDINGS WITH SOFT, WEAK OR OPEN-FRONT WALLS
SECTION 9301 PURPOSE
SECTION 9302 SCOPE
SECTION 9303 DEFINITIONS
1756 SECTION 9304 PRIORITY DESIGNATIONS
SECTION 9305 COMPLIANCE REQUIREMENTS
SECTION 9306 ADMINISTRATION
1757 SECTION 9307 OCCUPANT AND TENANT ADVISORY
SECTION 9308 HISTORICAL BULDINGS
SECTION 9309 ENGINEERING ANALYSIS
1758 SECTION 9310 INFORMATION REQUIRED ON PLANS
SECTION 9311 VIOLATION/PENALTY
SECTION 9312 SEVERABILITY
1759 CHAPTER 94 VOLUNTARY EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS
SECTION 9401 PURPOSE
SECTION 9402 SCOPE
SECTION 9403 DEFINITIONS
SECTION 9404 GENERAL REQUIREMENTS
1760 SECTION 9405 PRE-DESIGN INVESTIGATION
SECTION 9406 ANALYSIS AND DESIGN
1763 SECTION 9407 HISTORICAL BUILDINGS
SECTION 9408 QUALITY CONTROL
SECTION 9409 INFORMATION REQUIRED ON PLANS
TABLE 94-A ALUES FOR EXISTING MATERIALS
1765 CHAPTER 95 MANDATORY EARTHQUAKE HAZARD REDUCTION IN EXISTING NON-DUCTILE CONCRETE BUILDINGS
SECTION 9501 PURPOSE
SECTION 9502 SCOPE
SECTION 9503 DEFINITIONS
SECTION 9504 COMPLIANCE REQUIREMENTS
1766 SECTION 9505 ADMINISTRATION
SECTION 9506 OCCUPANT AND TENANT ADVISORY
1767 SECTION 9507 HISTORICAL BUILDINGS
SECTION 9508 ENGINEERING ANALYSIS
SECTION 9509 INFORMATION REQUIRED ON PLANS
SECTION 9510 VIOLATION/PENALTY
SECTION 9511 SEVERABILITY
1769 CHAPTER 96 VOLUNTARY EARTHQUAKE HAZARD REDUCTION IN EXISTING REINFORCED CONCRETE AND REINFORCED MASONRY WALL BUILDINGS WITH FLEXIBLE DIAPHRAGMS
SECTION 9601 PURPOSE
SECTION 9602 SCOPE
SECTION 9603 DEFINITIONS
SECTION 9604 ANALYSIS AND DESIGN
1771 SECTION 9605 MATERIALS OF CONSTRUCTION
SECTION 9606 INFORMATION REQUIRED ON PLANS
1773 CHAPTER 97 EXISTING BUILDINGS ENERGY AND WATER EFFICIENCY PROGRAM
SECTION 9701 TITLE
SECTION 9702 PURPOSE
SECTION 9703 SCOPE
SECTION 9704 DEFINITIONS
1774 SECTION 9705 BENCHMARKING AND SELF REPORTING OF ENERGY AND WATER CONSUMPTION INFORMATION
1775 SECTION 9706 ENERGY AND WATER AUDITS AND RETRO-COMMISSIONING
1777 SECTION 9707 RECORD MAINTENANCE
SECTION 9708 SCHEDULE FOR COMPLIANCE
TABLE 9708.2
1778 SECTION 9709 NONCOMPLIANCE FEE
SECTION 9710 SUBMITTAL FEES
SECTION 9711 BUILDING AND SAFETY DEVELOPMENT SURCHARGE
SECTION 9712 SEVERABILITY
1779 EXCERPTS FROM RELATED LOS ANGELES CITY CODES LOS ANGELES MUNICIPAL CODE
SECTION 28.10 BALLOON-USE FOR ADVERTISING
SECTION 28.11 CAPTIVE BALLOONS AND SIMILAR DEVICES
1781 DIVISION A — MISCELLANEOUS
SECTION 96.02 EXCAVATING, DEPOSITING, DUMPING – EARTH,SAND, GRAVEL, ETC. – WHERE PROHIBITED
SECTION 96.05 DECLARING CERTAIN AREA SUBJECT TO INUNDATION AND PROHIBITING CONSTRUCTION OF CERTAIN BUILDINGS THEREIN
CHAPTER IX, ARTICLE 6
DIVISION A — MISCELLANEOUS
SECTION 96.02 EXCAVATING, DEPOSITING, DUMPING – EARTH,SAND, GRAVEL, ETC. – WHERE PROHIBITED
SECTION 96.05 DECLARING CERTAIN AREA SUBJECT TO INUNDATION AND PROHIBITING CONSTRUCTION OF CERTAIN BUILDINGS THEREIN
1783 DIVISION C — FABRICATOR APPROVALS
SECTION 96.200 STATEMENT OF PURPOSE
SECTION 96.201 DEFINITIONS
SECTION 96.203 SCOPE AND EFFECT OF APPROVALS
SECTION 96.204 ISSUANCE OF APPROVALS – PROCEDURES
DIVISION C — FABRICATOR APPROVALS
SECTION 96.200 STATEMENT OF PURPOSE
SECTION 96.201 DEFINITIONS
SECTION 96.203 SCOPE AND EFFECT OF APPROVALS
SECTION 96.204 ISSUANCE OF APPROVALS – PROCEDURES
1785 SECTION 96.205 SUSPENSION AND REVOCATION OF APPROVALS
SECTION 96.205 SUSPENSION AND REVOCATION OF APPROVALS
1787 DIVISION D — REPORT OF RESIDENTIAL PROPERTY RECORDS AND PENDING AND RECORDED LIENS
SECTION 96.300 INTENT
SECTION 96.301 DEFINITIONS
SECTION 96.302 REPORTS REQUIRED
SECTION 96.303 APPLICATION
DIVISION D — REPORT OF RESIDENTIAL PROPERTY RECORDS AND PENDING AND RECORDED LIENS
SECTION 96.300 INTENT
SECTION 96.301 DEFINITIONS
SECTION 96.302 REPORTS REQUIRED
SECTION 96.303 APPLICATION
1788 SECTION 96.304 CONTENTS OF REPORTS
SECTION 96.304 CONTENTS OF REPORTS
1789 SECTION 96.305 FEE FOR REPORTS
SECTION 96.306 EFFECTIVE PERIOD OF REPORT
SECTION 96.307 DELIVERY OF THE REPORT
SECTION 96.308 EXCEPTIONS
SECTION 96.305 FEE FOR REPORTS
SECTION 96.306 EFFECTIVE PERIOD OF REPORT
SECTION 96.307 DELIVERY OF THE REPORT
SECTION 96.308 EXCEPTIONS
1790 SECTION 96.309 NON-COMPLIANCE NOT TO INVALIDATE SALE OR EXCHANGE: EXCEPTION
SECTION 96.309.1 INFORMATION FURNISHED AS GROUND FOR RESCISSION
SECTION 96.309 NON-COMPLIANCE NOT TO INVALIDATE SALE OR EXCHANGE: EXCEPTION
SECTION 96.309.1 INFORMATION FURNISHED AS GROUND FOR RESCISSION
1791 CHAPTER IX, ARTICLE 8 GENERAL ADMINISTRATIVE PROVISIONS
SECTION 98.0103 DEFINITIONS
SECTION 98.0105 INSPECTIONS
1792 SECTION 98.0109 EXPRESS PERMITS
1793 DIVISION 4 – APPEALS AND REQUEST FOR SLIGHT MODIFICATION APPEAL FEES – AVAILABILITY OF RECORDS FOR INSPECTION – BOARD RELATED SERVICES – INVESTIGATION –POWERS OF DEPARTMENT AND BOARD AND PENALTIES
SECTION 98.0402 CODE ENFORCEMENT COSTS INCURRED: INVESTIGATION COSTS, FEES AND FINES
SECTION 98.0403.1 POWERS OF THE DEPARTMENT AND THE BOARD
1796 SECTION 98.0403.2 PROCEDURES FOR APPEALS TO THE DEPARTMENT AND TO THE BOARD
SECTION 98.0404 EXTRA TERRITORIAL INSPECTIONS
1797 SECTION 98.0405 CHARGES FOR PRINTED MATERIALS AND MISCELLANEOUS TYPE SERVICES
SECTION 98.0406 INSPECTION FEES FOR OFF HOURS INSPECTION
SECTION 98.0407 SPECIAL ENFORCEMENT PROCEDURE FEES
SECTION 98.0408 ISSUANCE OF CITATIONS BY DESIGNATED EMPLOYEES
TABLE NO. 4-A FILING FEES* FOR APPEALS
TABLE NO. 4-B FILING FEES* FOR APPEALS GRADING AND SOIL REQUIREMENTS
TABLE NO. 4-C CHARGES FOR PRINTED MATERIALS
1798 SECTION 98.0410 SURCHARGE FOR ONE-STOP PERMIT CENTER
SECTION 98.0411 NONCOMPLIANCE FEES
1799 SECTION 98.0412 INSPECTION FEES
SECTION 98.0414 CERTIFICATION FEES
TABLE NO. 4D NONCOMPLIANCE INSPECTION FEES
SECTION 98.0415 CLERICAL, ISSUING OR RESEARCH FEES AND MISCELLANEOUS FEES
1800 SECTION 98.0416 BUILDING AND SAFETY SYSTEMS DEVELOPMENT SURCHARGE
SECTION 98.0417 PROCESSING FEES FOR MISCELLANEOUS CERTIFICATES OF COMPLIANCE
SECTION 98.0418 SURCHARGE FOR DEVELOPMENT OF AUTOMATED SYSTEMS FOR THE DEPARTMENT OF CITY PLANNING
SECTION 98.0420 REFUNDS OF DEPARTMENT FEES
SECTION 98.0421 CODE VIOLATION INSPECTION FEE
1801 SECTION 98.0422 FEES FOR OFF HOURS PLAN CHECK AND OTHER SERVICES
1803 DIVISION 5 — TESTING PROCEDURES, REGULATIONS AND ADMINISTRATION
SECTION 98.0501 PRODUCT APPROVAL, ALTERNATE MATERIALS, SYSTEMS, DEVICES AND METHODS OF CONSTRUCTION
1804 SECTION 98.0502 APPLIANCES, FIXTURES AND EQUIPMENT
TABLE NO. 5-AFEE SCHEDULE
1806 1. MECHANICAL TESTING LABORATORY FEES
1807 2. ELECTRICAL TESTING LABORATORY FEES
1809 SECTION 98.0503 TESTING AGENCIES
1810 SECTION 98.0504 ENVIRONMENTAL REPORTS
1811 DIVISION 6 — EXPIRATION AND REVOCATION OF PERMITS, PLAN CHECK AND SLIGHT MODIFICATIONS AND ALTERNATIVES
SECTION 98.0601 PURPOSE
SECTION 98.0602 EXPIRATION OF PERMITS
1812 SECTION 98.0603 EXPIRATION OF PLAN CHECK
SECTION 98.0604 EXPIRATION OF SLIGHT MODIFICATIONS AND ALTERNATIVES
SECTION 98.0605 TIME LIMITS OF REQUESTS FOR EXTENSION
1813 DIVISION 7 — ABATEMENT OF VACANT BUILDINGS
SECTION 98.0701 DECLARATION OF PURPOSE
SECTION 98.0702 DEFINITIONS
SECTION 98.0703 ENFORCEMENT AUTHORITY
SECTION 98.0704 ENFORCEMENT REMEDIES
SECTION 98.0705 STRICT LIABILITY OFFENSES
SECTION 98.0706 DUTY TO CLEAN, FENCE AND BARRICADE
SECTION 98.0707 ADMINISTRATIVE ABATEMENT PROCEDURES FOR VACANT AND UNSECURED STRUCTURES
1814 SECTION 98.0708 STANDARDS FOR FENCING AND BARRICADING A VACANT STRUCTURE
SECTION 98.0709 ENTRY OR INTERFERENCE WITH NOTICE PROHIBITED
SECTION 98.0710 CONTINUOUS ABATEMENT AUTHORITY
SECTION 98.0711 ABATEMENT COST
SECTION 98.0712 CONTINUOUS PUBLIC NUISANCES
SECTION 98.0713 DUTY TO FILE A STATEMENT OF INTENT
1815 SECTION 98.0714 POSTING NAME OF RESPONSIBLE PERSON
SECTION 98.0715 REINSPECTION FEE
SECTION 98.0716 VACANT STRUCTURE PENALTY
SECTION 98.0717 PROCEDURES FOR BARRICADED AND VACANT STRUCTURE PENALTY
1816 SECTION 98.0718 APPEAL OF BARRICADED AND VACANT STRUCTURE PENALTY
SECTION 98.0719 ADMINISTRATIVE ENFORCEMENT HEARING
SECTION 98.0720 FAILURE TO PAY PENALTIES
SECTION 98.0721 ALLOCATION OF VACANT BUILDING PENALTY
1817 CHAPTER XI, ARTICLE 1 NOISE REGULATION
SECTION 111.00 DECLARATION OF POLICY
SECTION 111.01 DEFINITIONS
SECTION 111.02 SOUND LEVEL MEASUREMENT PROCEDURE AND CRITERIA
1818 SECTION 111.03 MINIMUM AMBIENT NOISE LEVEL
SECTION 111.04 VIOLATIONS: ADDITIONAL REMEDIES, INJUNCTIONS
TABLE I OCTAVE BAND NOISE VALUES CORRESPONDING TO SOUND LEVEL”A” VALUES
TABLE II SOUND LEVEL”A” DECIBELS (In this chart, daytime levels are to be used from 7:00 a.m. to 10:00 p.m. and nighttime levels from 10:00 p.m. to 7:00 a.m.)
1819 SECTION 111.05 ENFORCEMENT, CITATIONS
1820 CHAPTER XI, ARTICLE 2 SPECIAL NOISE SOURCES
SECTION 112.01 RADIOS, TELEVISION SETS,AND SIMILAR DEVICES
SECTION 112.02 AIR CONDITIONING, REFRIGERATION,HEATING, PUMPING, FILTERING EQUIPMENT
SECTION 112.03 CONSTRUCTION NOISE
SECTION 112.04 POWERED EQUIPMENT INTENDED FOR REPETITIVE USE IN RESIDENTIAL AREAS AND OTHER MACHINERY, EQUIPMENT, AND DEVICES
SECTION 112.05 MAXIMUM NOISE LEVEL OF POWERED EQUIPMENT OR POWERED HAND TOOLS
1821 SECTION 112.06 PLACES OF PUBLIC ENTERTAINMENT
1822 CHAPTER XI, ARTICLE 6 GENERAL NOISE
SECTION 116.01 LOUD, UNNECESSARY AND UNUSUAL NOISE
1823 SECTION 19.100 DEFINITIONS
SECTION 19.101 ILLEGAL SIGNS – NUISANCE
SECTION 19.102 ENTRY UPON VACANT PRIVATE PROPERTY
SECTION 19.103 INTERFERENCE PROHIBITED
SECTION 19.104 NOTICE OF ILLEGAL SIGNS
SECTION 19.105 REMOVAL OF ILLEGAL SIGN
SECTION 19.106 COLLECTION OF COSTS
1825 INDEX
1867 HISTORY NOTE APPENDIX
1869 CODE RESOURCES FROM ICC
1870 ICC DIGITAL CODES PREMIUM
CA City of LA Building Code Vols1 2 2023 1stptg
$140.00