Shopping Cart

No products in the cart.

CA CityofLosAngelesResidentialCode 2017

$87.75

City of Los Angeles Residential Code

Published By Publication Date Number of Pages
CA 2017 709
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This package includes 2017 City of Los Angeles Residential Code amendment pages and the 2016 California Residential Code (Title 24, Part 2.5)

PDF Catalog

PDF Pages PDF Title
1 2017 CITY OF LOS ANGELES RESIDENTIAL CODE BASED ON THE 2016 CRC AND 2015 IRC®
2 2017 CITY OF LOS ANGELES RESIDENTIAL CODE BASED ON THE 2016 CRC AND 2015 IRC® TITLE PAGE
3 COPYRIGHT
4 CITY OF LOS ANGELES OFFICES
6 CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY PUBLISHED CODES
7 CITY OF LOS ANGELES DEPARTMENT OF BUILDING AND SAFETY MISSION STATEMENT
8 EFFECTIVE USE OF THE CITY OF LOS ANGELES RESIDENTIAL CODE
10 TABLE OF CONTENTS
16 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND APPLICATION
18 PART I ADMINISTRATIVE
CHAPTER 1 SCOPE AND APPLICATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
21 SECTION 1.2 RESERVED
SECTION 1.3 RESERVED
SECTION 1.4 RESERVED
SECTION 1.5 RESERVED
SECTION 1.6 RESERVED
SECTION 1.7 RESERVED
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT (HCD)
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
22 SECTION 1.8.3 LOCAL ENFORCING AGENCY
23 SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
24 SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
25 SECTION 1.8.8 APPEALS BOARD
SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
26 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 RESERVED
SECTION 1.10 RESERVED
SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
30 SECTION 1.12 RESERVED
SECTION 1.13 RESERVED
SECTION 1.14 RESERVED
31 DIVISION II ADMINISTRATION
SECTION R101 TITLE, PURPOSE, AND SCOPE
32 SECTION R102 UNSAFE BUILDINGS OR STRUCTURES
SECTION R103 VIOLATIONS
33 SECTION R104 ORGANIZATION AND ENFORCEMENT
34 SECTION R105 APPEALS
37 SECTION R106 PERMITS
46 SECTION R107 FEES
51 SECTION R108 INSPECTION
54 SECTION R109 CERTIFICATE OF OCCUPANCY
55 SECTION R110 RESPONSIBILITY OF PERMITTEE
SECTION R111 CODE REVISION
SECTION R112 RESERVED
SECTION R113 PERMIT FEES
TABLE 1-A PERMIT FEES 1,2,3,4
56 TABLE 1-A.1 COMBINED PERMIT FEES
TABLE 1-B TEMPORARY CERTIFICATE OF OCCUPANCY ADDITIONAL FEES
TABLE 1-C REPORT FEES a,b,c,d,e
TABLE 1-D GRADING PERMIT FEES
58 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
59 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
60 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
61 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
62 PART II DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
76 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING
77 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING—continued
78 PART III BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 SITE DRAINAGE
SECTION R301 DESIGN CRITERIA
79 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
82 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) (psf)
83 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
84 FIGURE R301.2(1) ISOLINES OF THE 971/2 PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
85 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES—SITE CLASS D
86 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
87 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
88 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
89 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES—SITE CLASS D
90 FIGURE R301.2(3) WEATHERING PROBABILITY MAP FOR CONCRETEa, b
91 FIGURE R301.2(4)A ULTIMATE DESIGN WIND SPEEDS
92 FIGURE R301.2(4)B REGIONS WHERE WIND DESIGN IS REQUIRED
93 FIGURE R301.2(5) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
94 FIGURE R301.2(5)—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
95 FIGURE R301.2(6) TERMITE INFESTATION PROBABILITY MAP
96 FIGURE R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES
97 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
98 TABLE R301.2.1.3 WIND SPEED CONVERSIONS
99 TABLE R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
100 FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION
TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
103 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
104 TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS
SECTION R302 FIRE-RESISTANT CONSTRUCTION
105 TABLE R302.1(1) EXTERIOR WALLS
TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS AND ACCESSORY BUILDINGS WITH AUTOMATIC RESIDENTIAL FIRE SPRINKLER PROTECTION
108 TABLE R302.6 DWELLING-GARAGE AND/OR CARPORT SEPARATION
110 SECTION R303 LIGHT, VENTILATION AND HEATING
111 SECTION R304 MINIMUM ROOM AREAS
112 SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
113 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
114 FIGURE R308.4.7 PROHIBITED GLAZING LOCATIONS AT BOTTOM STAIR LANDINGS
115 SECTION R309 GARAGES AND CARPORTS
116 SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
117 SECTION R311 MEANS OF EGRESS
120 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
121 SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
122 TABLE R313.3.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
124 FIGURE R313.3.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
125 EQUATION 29-1
127 TABLE R313.3.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
TABLE R313.3.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
128 TABLE R313.3.6.2(3) ELEVATION LOSS (PLe)
TABLE R313.3.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
129 TABLE R313.3.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
130 TABLE R313.3.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
131 TABLE R313.3.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
132 TABLE R313.3.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
133 TABLE R313.3.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
SECTION R314 SMOKE ALARMS
137 SECTION R315 CARBON MONOXIDE ALARMS
139 SECTION R316 FOAM PLASTIC
140 SECTION R317 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS AGAINST DECAY
142 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
143 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY
SECTION R321 ELEVATORS AND PLATFORM LIFTS
SECTION R322 FLOOD-RESISTANT CONSTRUCTION
146 SECTION R323 STORM SHELTERS
SECTION 324 SOLAR ENERGY SYSTEMS
147 SECTION R325 MEZZANINES
148 SECTION R326 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION R334 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING
SECTION R335 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-3.1
151 SECTION R336 LARGE FAMILY DAY-CARE HOMES
152 SECTION R337 MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION R337.1 SCOPE, PURPOSE AND APPLICATION
153 SECTION R337.2 DEFINITIONS
154 SECTION R337.3 STANDARDS OF QUALITY
155 SECTION R337.4 IGNITION RESISTANT CONSTRUCTION
SECTION R337.5 ROOFING
156 SECTION R337.6 VENTS
SECTION R337.7 EXTERIOR COVERING
158 SECTION R337.8 EXTERIOR WINDOWS AND DOORS
159 SECTION R337.9 DECKING
SECTION R337.10 ACCESSORY STRUCTURES
SECTION R338 ELECTRIC VEHICLE
160 SECTION R340 POLLUTANT CONTROL
162 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 4 – FOUNDATIONS
CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
163 TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
SECTION R402 MATERIALS
164 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
166 TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION (inches)a, b
167 TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER (inches)a, b
168 TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE CONCRETE OR FULLY GROUTED MASONRY WALL CONSTRUCTION (inches)a, b
169 FIGURE R403.1(1) PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SDC A, B AND C
170 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
171 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
172 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEM WALLS IN SDC D0, D1 AND D2
173 FIGURE R403.1.5 STEPPED FOOTING
176 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
178 TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST PROTECTED FOOTINGS IN HEATED BUILDINGS
179 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
180 TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
181 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
182 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
183 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
184 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
185 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
186 FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
TABLE R403.4 MINIMUM DEPTH OF CRUSHED STONE FOOTINGS (D), (inches)
187 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
SECTION R404 FOUNDATION AND RETAINING WALLS
188 TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLSf
189 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 5 INCHESa, c, f
190 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 6.75 INCHESa, c, f
191 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 8.75 INCHESa, c, f
192 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLSa, b
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, g, h, i, j
193 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i, j
194 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLSb, c, d, e, f, h, i, j
195 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, g, h, i,
196 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLSb, c, d, e, f, h, i, j, k
197 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLSb, c, d, e, g, h, i, j
198 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10-INCH AND 12-INCH NOMINAL FLAT BASEMENT WALLSb, c, d, e, f, h, i, k, n, o
199 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND/OR ALTERNATE GRADE OF STEELa, b, c
202 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
204 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
205 SECTION R405 FOUNDATION DRAINAGE
206 TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING
207 SECTION R407 COLUMNS
SECTION R408 UNDER-FLOOR SPACE
210 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 5 – FLOORS
CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
213 FIGURE R502.2 FLOOR CONSTRUCTION
214 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
215 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
216 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
217 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
218 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLYa, b, c, f, g, h (Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONYa, b, e, f
219 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
220 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c
221 FIGURE R5.503.2.4 OPENINGS IN HORIZONTAL DIAPHRAGMS
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVE TREATED WOOD FLOORS (ON GROUND)
222 SECTION R505 COLD-FORMED STEEL FLOOR FRAMING
225 FIGURE R505.1.2 IN-LINE FRAMING
TABLE R505.2.3 COLD-FORMED STEEL JOIST SIZES AND THICKNESS
226 FIGURE R505.2.3(1) C-SHAPED SECTION
FIGURE R505.2.3(2) TRACK SECTION
FIGURE R505.2.6.1 FLOOR JOIST WEB HOLES
227 FIGURE R505.2.6.3 FLOOR JOIST WEB HOLE PATCH
228 TABLE R505.3.1(1) FLOOR TO FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
FIGURE 505.3.1(1) FLOOR TO EXTERIOR LOAD-BEARING WALL STUD CONNECTION
229 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(2) FLOOR TO WOOD SILL CONNECTION
230 FIGURE R505.3.1(3) FLOOR TO FOUNDATION CONNECTION
FIGURE R505.3.1(4) CANTILEVERED FLOOR TO FOUNDATION CONNECTION
231 FIGURE R505.3.1(5) CANTILEVERED FLOOR TO WOOD SILL CONNECTION
FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
232 FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
233 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
234 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE OR CONTINUOUS SPANSa, b, c, d, e
SECTION R506 CONCRETE FLOORS (ON GROUND)
235 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
236 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
SECTION R507 EXTERIOR DECKS
237 FIGURE R505.3.4(2) BEARING STIFFENER
FIGURE R505.3.7 TRACK SPLICE
238 FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING
239 FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
240 FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
TABLE R507.2 DECK LEDGER CONNECTION TO BAND JOISTa, b (Deck live load = 40 psf, deck dead load = 10 psf, snow load ≤ 40 psf)
241 TABLE 507.2.1 PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
FIGURE R507.2.1(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
FIGURE R507.2.1(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
242 FIGURE 507.2.3(1) DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R507.2.3(2) DECK ATTACHMENT FOR LATERAL LOADS
243 TABLE R507.4 MAXIMUM JOIST SPACING
TABLE R507.5 DECK JOIST SPANS FOR COMMON LUMBER SPECIESf (ft. – in.)
244 FIGURE R507.5 TYPICAL DECK JOIST SPANS
TABLE R507.6 DECK BEAM SPAN LENGTHSa, b (ft. – in.)
245 FIGURE R507.6 TYPICAL DECK BEAM SPANS
FIGURE R507.7.1 DECK BEAM TO DECK POST
TABLE R507.8 DECK POST HEIGHTa
FIGURE R507.8.1 TYPICAL DECK POSTS TO DECK FOOTINGS
246 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 6 – WALL CONSTRUCTION
CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
248 TABLE R602.3(1) FASTENING SCHEDULE
249 TABLE R602.3(1)—continued FASTENING SCHEDULE
250 TABLE 602.3(1)FASTENING SCHEDULE—continued
251 TABLE R602.3(1)—continued FASTENING SCHEDULE
TABLE R602.3.2 SINGLE TOP-PLATE SPLICE CONNECTION DETAILS
252 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
253 TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
254 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
255 FIGURE R602.3(2) FRAMING DETAILS
257 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
258 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
259 FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
TABLE R602.7.5 MINIMUM NUMBER OF FULL HEIGHT STUDS AT EACH END OF HEADERS IN EXTERIOR WALLS
260 TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
261 TABLE R602.7(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
262 TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R602.7(3) GIRDER AND HEADER SPANSa FOR OPEN PORCHES (Maximum span for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb)
263 FIGURE R602.7.1(1) SINGLE MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE MEMBER HEADER WITHOUT CRIPPLE
FIGURE R602.7.2 RIM BOARD HEADER CONSTRUCTION
264 TABLE R602.7.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
265 FIGURE R602.10.1.1 BRACED WALL LINES
TABLE R602.10.1.3 BRACED WALL LINE SPACING
268 FIGURE R602.10.1.4 ANGLED WALLS
FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
269 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
270 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
271 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
272 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
273 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
274 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
275 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
276 TABLE R602.10.4 BRACING METHODS
277 TABLE R602.10.4—continued BRACING METHODS
278 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
279 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
280 TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
281 FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS AT GARAGE DOOR OPENINGS
282 FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
283 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
284 TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELS
285 TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
286 FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
287 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
289 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
290 FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
291 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
293 FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
294 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
295 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
296 FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
SECTION R603 COLD-FORMED STEEL WALL FRAMING
TABLE R603.2.3 LOAD-BEARING COLD-FORMED STEEL STUD SIZES AND THICKNESSES
297 FIGURE R603.1.2 IN-LINE FRAMING
FIGURE R603.2.3(1) C-SHAPED SECTION
FIGURE R603.2.3(2) TRACK SECTION
298 FIGURE R603.2.6.1 WALL STUD WEB HOLES
299 FIGURE R603.2.6.3 WALL STUD WEB HOLE PATCH
300 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS
TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
301 FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS
302 FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
303 FIGURE R603.3.1(4) WIND UPLIFT CONNECTOR
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
304 TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
305 TABLE R603.3.2(3) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
306 TABLE R603.3.2(4) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
307 TABLE R603.3.2(5) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
308 TABLE R603.3.2(6) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
309 TABLE R603.3.2(7) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
310 TABLE R603.3.2(8) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
311 TABLE R603.3.2(9) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
312 TABLE R603.3.2(10) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
313 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILINGa, b, c, d
314 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
315 TABLE R603.3.2(13) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILINGa, b, c, d
316 TABLE R603.3.2(14) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
317 TABLE R603.3.2(15) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
318 TABLE R603.3.2(16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
319 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHTa, b, c, d
320 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHTa, b, c, d
321 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
322 FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
323 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
324 TABLE R603.6(1) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
325 TABLE R603.6(2) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
326 TABLE R603.6(3) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
327 TABLE R603.6(4) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
328 TABLE R603.6(5) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
329 TABLE R603.6(6) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
330 FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
331 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTSa, b, c, d
332 TABLE R603.8 HEAD AND SILL TRACK SPAN
FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
333 TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLSa, b
TABLE R603.9.2(2) FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
FIGURE R603.9.4.2 CORNER STUD HOLD-DOWN DETAIL
334 TABLE R603.9.5(1) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
335 TABLE R603.9.5(2) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
336 TABLE R603.9.5(3) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
337 TABLE R603.9.5(4) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
SECTION R606 GENERAL MASONRY CONSTRUCTION
338 TABLE R606.2.7 MORTAR PROPORTIONSa, b
339 TABLE R606.2.11 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
TABLE R606.3.4.1 MINIMUM CORROSION PROTECTION
340 TABLE R606.3.5.1 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
341 TABLE R606.6.4 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
342 TABLE R606.9 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
344 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
345 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
346 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D
347 TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
348 TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
349 SECTION R607 GLASS UNIT MASONRY
350 FIGURE R607.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
351 SECTION R608 EXTERIOR CONCRETE WALL CONSTRUCTION
352 TABLE R608.3 DIMENSIONAL REQUIREMENTS FOR WALLSa, b
FIGURE R608.3(1) FLAT WALL SYSTEM
353 FIGURE R6083(2) WAFFLE-GRID WALL SYSTEM
FIGURE R608.3(3) SCREEN-GRID WALL SYSTEM
355 TABLE R608.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R608.5.4(1) LAP SPLICES
356 FIGURE R608.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
FIGURE R608.5.4(3) STANDARD HOOKS
357 TABLE R608.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND/OR ALTERNATIVE GRADE OF STEELa, b, c
359 FIGURE R608.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R608.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST STORY AND LIGHT-FRAMED SECOND STORY
FIGURE R608.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
360 TABLE R608.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLSa, b, c, d, e
361 TABLE R608.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLSa, b, c, d, e
362 TABLE R608.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLSa, b, c, d, e
363 TABLE R608.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLSa, b, c, d, e, k, l
364 EQUATION R6-1
EQUATION R6-2
365 TABLE R608.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
366 TABLE R608.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
367 TABLE R608.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
368 TABLE R608.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
369 TABLE R608.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
370 TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
371 TABLE R608.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R608.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEETa, b
372 TABLE R608.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLSa, c
373 FIGURE R608.7(1) MINIMUM SOLID WALL LENGTH
375 FIGURE R608.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
376 FIGURE R608.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
377 FIGURE R608.8(1) REINFORCEMENT OF OPENINGS
378 FIGURE R608.8(2) LINTEL FOR FLAT WALLS
FIGURE R608.8(3) LINTELS FOR WAFFLE-GRID WALLS
379 FIGURE R608.8(4) LINTELS FOR SCREEN-GRID WALLS
380 TABLE R608.8(1) LINTEL DESIGN LOADING CONDITIONS
381 TABLE R608.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
382 TABLE R608.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
383 TABLE R608.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
384 TABLE R608.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
385 TABLE R608.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
386 TABLE R608.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
387 TABLE R608.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
388 TABLE R608.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
389 TABLE R608.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
390 TABLE R608.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
391 TABLE R608.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
392 TABLE R608.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
393 TABLE R608.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
394 TABLE R608.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g, h
395 TABLE R608.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
TABLE R608.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSc, d, e, f, g
397 FIGURE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
398 TABLE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULARa, b
399 FIGURE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
400 TABLE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLELa, b
401 FIGURE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING, PERPENDICULAR
402 TABLE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
403 FIGURE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
404 TABLE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
405 FIGURE R608.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
406 TABLE R608.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
407 FIGURE R608.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
408 TABLE R608.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
409 FIGURE R608.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
410 TABLE R608.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
411 FIGURE R608.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
412 TABLE R608.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
413 FIGURE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
414 TABLE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
415 FIGURE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
416 TABLE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
417 FIGURE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
418 TABLE R608.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
419 FIGURE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
420 TABLE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
421 SECTION R609 EXTERIOR WINDOWS AND DOORS
422 FIGURE R609.7.2(1) THROUGH THE FRAME
FIGURE R609.7.2(2) FRAME CLIP
FIGURE R609.7.2(3) THROUGH THE FRAME
FIGURE R609.7.2(4) FRAME CLIP
423 FIGURE R609.7.2(5) THROUGH THE FLANGE
FIGURE R609.7.2(6) THROUGH THE FLANGE
FIGURE R609.7.2(7) FRAME CLIP
FIGURE R609.7.2(8) THROUGH THE FLANGE
424 SECTION R610 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
TABLE R610.3.1 MINIMUM PROPERTIES FOR POLYURETHANE INSULATION USED AS SIPS CORE
425 TABLE R610.3.2 MINIMUM PROPERTIESa FOR ORIENTED STRAND BOARD FACER MATERIAL IN SIP WALLS
FIGURE R610.4 SIP WALL PANEL
426 TABLE R610.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches)a
427 TABLE R610.5(2) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF ONLY (inches)a
428 FIGURE R610.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R610.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
429 FIGURE R610.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R610.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
430 FIGURE R610.5(5) SIP WALL-TO-WALL BALLOON FRAME CONNECTION (I-Joist floor shown for Illustration only)
FIGURE R610.5.1 SIP WALL FRAMING CONFIGURATION
431 FIGURE R610.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R610.8 TYPICAL SIP CONNECTION DETAILS FOR VERTICAL IN-PLANE JOINTS
432 FIGURE R610.9 SIP CORNER FRAMING DETAIL
TABLE R610.10 MAXIMUM SPANS FOR 117/8-INCH-DEEP SIP HEADERS (feet)a
434 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 7 – WALL COVERING
CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
435 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
436 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
437 TABLE R702.3.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
438 TABLE R702.4.2 BACKER BOARD MATERIALS
SECTION R703 EXTERIOR COVERING
439 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTION
TABLE R703.3.1 LIMITS FOR ATTACHMENT PER TABLE R703.3(1)
440 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
441 TABLE R703.3(1)—continued SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
442 TABLE R703.3.2 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
443 TABLE R703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa, b, c (Dimensions are in inches)
444 TABLE R703.6.3(1) SINGLE COURSE SIDEWALL FASTENERS
TABLE R703.6.3(2) DOUBLE COURSE SIDEWALL FASTENERS
446 FIGURE R703.8 TYPICAL MASONRY VENEER WALL DETAILS
447 FIGURE R703.8—continued TYPICAL MASONRY VENEER WALL DETAILSe
448 TABLE R703.8.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
FIGURE R703.8.3.2 MASONRY VENEER OPENING
TABLE R703.8(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.8(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
449 FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
450 TABLE R703.8.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEERa, b, c, d
TABLE R703.8.4 TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
454 TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa, b
455 TABLE R703.16.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
TABLE R703.16.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
456 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 8 – ROOF-CEILING CONSTRUCTION
CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
459 TABLE R802.4(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
460 TABLE R802.4(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
461 TABLE R802.4(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
462 TABLE R802.4(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
463 TABLE R802.5.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
464 TABLE R802.5.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling not attached to rafters, L/Δ = 180)
465 TABLE R802.5.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
466 TABLE R802.5.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load=20 psf, ceiling attached to rafters, L/Δ = 240)
467 TABLE R802.5.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
468 TABLE R802.5.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling not attached to rafters, L/Δ = 180)
469 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
470 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling not attached to rafters, L/Δ = 180)
471 TABLE R802.5.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
472 TABLE R802.5.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=30 psf, ceiling attached to rafters, L/Δ = 240)
473 TABLE R802.5.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
474 TABLE R802.5.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load=50 psf, ceiling attached to rafters, L/Δ = 240)
475 TABLE R802.5.1(7) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
476 TABLE R802.5.1(7)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling not attached to rafters, L/Δ = 180)
477 TABLE R802.5.1(8) RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
478 TABLE R802.5.1(8)—continued RAFTER SPANS FOR 70 PSF GROUND SNOW LOAD (Ceiling attached to rafters, L/Δ = 240)
479 TABLE R802.5.1(9) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS
480 FIGURE R802.5.1 BRACED RAFTER CONSTRUCTION
481 FIGURE R802.7.1.1 RAFTER NOTCH
FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
482 SECTION R803 ROOF SHEATHING
483 TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION
484 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (POUNDS PER CONNECTION
485 SECTION R804 COLD-FORMED STEEL ROOF FRAMING
486 FIGURE R804.1.2 IN-LINE FRAMING
TABLE R804.2.3 LOAD-BEARING COLD-FORMED STEEL ROOF FRAMING MEMBER SIZES AND THICKNESSES
487 FIGURE R804.2.3(1) C-SHAPED SECTION
FIGURE R804.2.3(2) TRACK SECTION
488 FIGURE R804.2.6.1 ROOF FRAMING MEMBER WEB HOLES
FIGURE R804.2.6.3 ROOF FRAMING MEMBER WEB HOLE PATCH
489 FIGURE R804.3 COLD-FORMED STEEL ROOF CONSTRUCTION
TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE
490 TABLE R804.3.1.1(1) CEILING JOIST SPANS 10 PSF LIVE LOAD (NO ATTIC STORAGE)a, b, c
491 TABLE R804.3.1.1(2) CEILING JOIST SPANS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)a, b, c
492 TABLE R804.3.1.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
FIGURE R804.3.1.1 JOIST TO RAFTER CONNECTION
493 FIGURE R804.3.1.3(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPED, TRACK OR COLD-ROLLED CHANNEL
FIGURE R804.3.1.3(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
494 FIGURE R804.3.1.4 SPLICED CEILING JOISTS
495 TABLE R804.3.2.1(1) ROOF RAFTER SPANS
TABLE R804.3.2.1(2) ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
496 FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
497 FIGURE R804.3.2.4 RIDGE MEMBER CONNECTION
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
498 FIGURE R804.3.5(1) ROOF OR CEILING OPENING
499 FIGURE R804.3.5(2) HEADER TO TRIMMER CONNECTION
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
500 TABLE R804.3.7.1 REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEETa, b, c, d, e, f, g
FIGURE R804.3.7.1(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
501 FIGURE R804.3.7.1(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
FIGURE R804.3.7(2) ROOF BLOCKING DETAIL
503 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
SECTION R807 ATTIC ACCESS
504 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 9 – ROOF ASSEMBLIES
CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 FIRE CLASSIFICATION
505 SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
506 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
TABLE R905.1.1(1) UNDERLAYMENT TYPES
507 TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
508 TABLE R905.1.1(3) UNDERLAYMENT ATTACHMENT
509 TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES
510 TABLE R905.2.8.2 VALLEY LINING MATERIAL
TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
511 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
512 TABLE R905.7.5(1) WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.7.5(2)NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
513 TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
514 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
515 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
516 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 ROOFTOP-MOUNTED PHOTOVOLTAIC SYSTEMS
SECTION R908 REROOFING
517 SECTION R909 ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
SECTION R918 SOLAR PHOTOVOLTAIC PANELS/MODULES
518 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 10 – CHIMNEYS AND FIREPLACES
CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
519 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
520 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
522 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
SECTION R1002 MASONRY HEATERS
SECTION R1003 MASONRY CHIMNEYS
524 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
525 TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
TABLE R1003.20 CRICKET DIMENSIONS
526 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
527 FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1004 FACTORY-BUILT FIREPLACES
SECTION R1005 FACTORY-BUILT CHIMNEYS
SECTION R1006 EXTERIOR AIR SUPPLY
530 PART IV – ENERGY CONSERVATION
532 PART V – MECHANICAL
534 PART VI – FUEL GAS
536 PART VII – PLUMBING
538 PART VIII – ELECTRICAL
540 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 44 – REFERENCED STANDARDS
542 PART IX – REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACI
ACCA
543 AISI
AMCA
AMD
ANCE
ANSI
545 APA
ASCE/SEI
ASHRAE
ASME
547 ASSE
548 ASTM
557 AWC
AWPA
AWS
558 AWWA
CEN
CGSB
CISPI
559 CPA
CPSC
CSA
561 CSSB
DASMA
DOC
DOTn
FEMA
562 FM
GA
HPVA
IAPMO
ICC
563 ISO
MSS
NAIMA
564 NFPA
567 NSF
PCA
SBCA
SFM
568 SMACNA
SRCC
TMS
TPI
569 UBC
UL
570 ULC
WDMA
572 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX A – SIZING AND CAPACITIES OF GAS PIPING
APPENDIX A SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
573 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
574 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
575 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
577 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
578 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
579 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
580 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
582 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX B – SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
APPENDIX B SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES, AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
583 FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
584 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE BDOUBLE-WALL VENT CONNECTOR
585 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
586 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
587 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
EXAMPLES USING COMMON VENTING TABLES
588 FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
590 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
591 FIGURE B-19
592 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX C – EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
594 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX D – RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
APPENDIX D RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
595 D.2 OCCUPANT AND INSPECTOR SAFETY
D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
596 D.5 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE OPERATING
597 D.6 APPIANCE-SPECIFIC INSPECTIONS
599 TABLE D.6 CO THRESHOLDS
600 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX E – MANUFACTURED HOUSING USED AS DWELLINGS
APPENDIX E MANUFACTURED HOUSING USED AS DWELLINGS
SECTION AE101 SCOPE
SECTION AE102 APPLICATION TO EXISTING MANUFACTURED HOMES AND BUILDING SERVICE EQUIPMENT
601 SECTION AE201 DEFINITIONS
602 SECTION AE301 PERMITS
SECTION AE302 APPLICATION FOR PERMIT
SECTION AE303 PERMITS ISSUANCE
603 SECTION AE304 FEES
604 SECTION AE305 INSPECTIONS
605 SECTION AE306 SPECIAL INSPECTIONS
SECTION AE307 UTILITY SERVICE
SECTION AE401 OCCUPANCY CLASSIFICATION
SECTION AE402 LOCATION ON PROPERTY
SECTION AE501 DESIGN
SECTION AE502 FOUNDATION SYSTEMS
606 SECTION AE503 SKIRTING AND PERIMETER ENCLOSURES
SECTION AE504 STRUCTURAL ADDITIONS
SECTION AE505 BUILDING SERVICE EQUIPMENT
SECTION AE506 EXITS
SECTION AE507 OCCUPANCY, FIRE SAFETY AND ENERGY CONSERVATION STANDARDS
SECTION AE600 SPECIAL REQUIREMENTS FOR FOUNDATION SYSTEMS
SECTION AE601 FOOTINGS AND FOUNDATIONS
SECTION AE602 PIER CONSTRUCTION
607 SECTION AE603 HEIGHT OF PIERS
SECTION AE604 ANCHORAGE INSTALLATIONS
608 SECTION AE605 TIES, MATERIALS AND INSTALLATION
SECTION AE606 REFERENCED STANDARDS
610 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX F – PASSIVE RADON GAS CONTROLS
APPENDIX F PASSIVE RADON GAS CONTROLS
SECTION AF101 SCOPE
SECTION AF102 DEFINITIONS
611 SECTION AF103 PASSIVE RADON-RESISTANT SYSTEM REQUIREMENTS
613 FIGURE AF101 EPA MAP OF RADON ZONES
614 TABLE AF101(1) HIGH RADON-POTENTIAL (ZONE 1) COUNTIESa
615 TABLE AF101(1)—continued HIGH RADON-POTENTIAL (ZONE 1) COUNTIESa
616 FIGURE AF102 RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES
618 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX G – PIPING STANDARDS FOR VARIOUS APPLICATIONS
APPENDIX G PIPING STANDARDS FOR VARIOUS APPLICATIONS
SECTION AG101 PLASTIC PIPING STANDARDS
SECTION AG102 REFERENCED STANDARDS
619 TABLE AG101.1 PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa
620 TABLE AG101.1—continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa
621 TABLE AG101.1—continued PLASTIC PIPING STANDARDS FOR VARIOUS APPLICATIONSa
622 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX H – PATIO COVERS
APPENDIX H PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 EXTERIOR WALLS AND OPENINGS
SECTION AH104 HEIGHT
SECTION AH105 STRUCTURAL PROVISIONS
623 SECTION AH106 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
TABLE AH106.4(1) DESIGN WIND PRESSURES FOR SCREEN ENCLOSURE FRAMINGa, b, e, f, g, h
624 TABLE AH106.4(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE
625 FIGURE AH106.4.1 ULTIMATE DESIGN WIND SPEEDS FOR PATIO COVERS AND SCREEN ENCLOSURES
626 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX I – PRIVATE SEWAGE DISPOSAL
APPENDIX I PRIVATE SEWAGE DISPOSAL
SECTION AI101 GENERAL
628 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX J – EXISTING BUILDINGS AND STRUCTURES
APPENDIX J EXISTING BUILDINGS AND STRUCTURES
SECTION AJ101 PURPOSE AND INTENT
SECTION AJ102 COMPLIANCE
629 SECTION AJ103 PRELIMINARY MEETING
SECTION AJ104 EVALUATION OF AN EXISTING BUILDING
SECTION AJ105 PERMIT
630 SECTION AJ201 DEFINITIONS
SECTION AJ301 REPAIRS
SECTION AJ401 RENOVATIONS
631 SECTION AJ501 ALTERATIONS
632 SECTION AJ601 RECONSTRUCTION
634 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX K – SOUND TRANSMISSION
APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIR-BORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
636 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX L – PERMIT FEES
APPENDIX L PERMIT FEES
638 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX M – HOME DAY CARE—R-3 OCCUPANCY
APPENDIX M HOME DAY CARE—R-3 OCCUPANCY
640 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX N – VENTING METHODS
APPENDIX N VENTING METHODS
FIGURE N1 TYPICAL SINGLE-BATH WET-VENT ARRANGEMENTS
641 FIGURE N2 TYPICAL DOUBLE-BATH WET-VENT ARRANGEMENTS
642 FIGURE N3 TYPICAL HORIZONTAL WET VENTING
643 FIGURE N4 TYPICAL METHODS OF WET VENTING
644 FIGURE N5 SINGLE STACK SYSTEM FOR A TWO-STORY DWELLING
645 FIGURE N6 WASTE STACK VENTING
FIGURE N7 CIRCUIT VENT WITH ADDITIONAL NONCIRCUIT VENTED BRANCH
646 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX O – AUTOMATIC VEHICULAR GATES
APPENDIX O AUTOMATIC VEHICULAR GATES
SECTION AO101 GENERAL
SECTION AO102 DEFINITION
SECTION AO103 AUTOMATIC VEHICULAR GATES
648 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX P – SIZING OF WATER PIPING SYSTEM
APPENDIX P SIZING OF WATER PIPING SYSTEM
SECTION AP101 GENERAL
SECTION AP102 INFORMATION REQUIRED
SECTION AP103 SELECTION OF PIPE SIZE
653 TABLE AP.1
TABLE AP.2
FIGURE AP103.3(1) EXAMPLE—SIZING
654 TABLE AP103.3(1) RECOMMENDED TABULAR ARRANGEMENT FOR USE IN SOLVING PIPE SIZING PROBLEMS
655 TABLE AP103.3(2) LOAD VALUES ASSIGNED TO FIXTURESa
656 TABLE AP103.3(3) TABLE FOR ESTIMATING DEMAND
657 TABLE AP103.3(3)—continued TABLE FOR ESTIMATING DEMAND
TABLE AP103.3(4) LOSS OF PRESSURE THROUGH TAPS AND TEES IN POUNDS PER SQUARE INCH (psi)
658 TABLE AP103.3(5) ALLOWANCE IN EQUIVALENT LENGTHS OF PIPE FOR FRICTION LOSS IN VALVES AND THREADED FITTINGS (feet)
TABLE AP103.3(6) PRESSURE LOSS IN FITTINGS AND VALVES EXPRESSED AS EQUIVALENT LENGTH OF TUBEa (feet)
659 FIGURE AP103.3(2) FRICTION LOSS IN SMOOTH PIPEa (TYPE K, ASTM B88 COPPER TUBING)
660 FIGURE AP103.3(3) FRICTION LOSS IN SMOOTH PIPEa (TYPE L, ASTM B88 COPPER TUBING)
661 FIGURE AP103.3(4) FRICTION LOSS IN SMOOTH PIPEa (TYPE M, ASTM B88 COPPER TUBING)
662 FIGURE AP103.3(5) FRICTION LOSS IN FAIRLY SMOOTH PIPEa
663 FIGURE AP103.3(6) FRICTION LOSS IN FAIRLY ROUGH PIPEa
664 FIGURE AP103.3(7) FRICTION LOSS IN ROUGH PIPEa
665 SECTION AP201 SELECTION OF PIPE SIZE
666 TABLE AP201.1 MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
667 TABLE AP201.1—continued MINIMUM SIZE OF WATER METERS, MAINS AND DISTRIBUTION PIPING BASED ON WATER SUPPLY FIXTURE UNIT VALUES (w.s.f.u.)
668 APPENDIX Q RESERVED
670 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX R – LIGHT STRAW-CLAY CONSTRUCTION
APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
SECTION AR102 DEFINITIONS
SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
672 SECTION AR104 THERMAL INSULATION
SECTION AR105 REFERENCED STANDARD
674 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX S – STRAWBALE CONSTRUCTION
APPENDIX S STRAWBALE CONSTRUCTION
SECTION AS101 GENERAL
SECTION AS102 DEFINITIONS
675 SECTION AS103 BALES
SECTION AS104 FINISHES
676 SECTION AS105 STRAWBALE WALLS—GENERAL
677 TABLE AS105.4 OUT-OF-PLANE RESISTANCE AND UNRESTRAINED WALL DIMENSIONS
678 SECTION AS106 STRAWBALE WALLS—STRUCTURAL
TABLE AS106.6.1 MINIMUM COMPRESSIVE STRENGTH FOR PLASTERS ON STRUCTURAL WALLS
679 TABLE AS106.12 ALLOWABLE SUPERIMPOSED VERTICAL LOADS (LBS/FOOT) FOR PLASTERED LOAD-BEARING STRAWBALE WALLS
680 TABLE AS106.13(1) PLASTERED STRAWBALE BRACED WALL PANEL TYPES
SECTION AS107 FIRE RESISTANCE
681 TABLE AS106.13(2) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON WIND SPEED
682 TABLE AS106.13(3) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY
SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
684 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX T – RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER N1102.4 OR N1105 CONDITIONS
APPENDIX T RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER N1102.4 OR N1105 CONDITIONS £ 5ACH
SECTION T101 SCOPE
SECTION T202 GENERAL DEFINITIONS
SECTION T301 TESTING PROCEDURE
685 TABLE T301.1(1) CAZ DEPRESSURIZATION LIMITS
TABLE T301.1(2) ACCEPTABLE DRAFT TEST CORRECTION
686 TABLE T301.1(3) ACCEPTABLE DRAFT TEST CORRECTION
688 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX U – SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS, MULTIPLE SINGLE- FAMILY DWELLINGS (TOWNHOUSES)
APPENDIX U SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS, MULTIPLE SINGLE- FAMILY DWELLINGS (TOWNHOUSES)
SECTION U101 SCOPE
SECTION U102 GENERAL DEFINITIONS
SECTION U103 SOLAR-READY ZONE
690 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX V – SWIMMING POOL SAFETY ACT
APPENDIX V SWIMMING POOL SAFETY ACT
AV100 PRIVATE SWIMMING POOLS (STATEWIDE)
AV100.1 DEFINITIONS
AV100.2 CONSTRUCTION PERMIT: SAFETY FEATURES REQUIRED
691 AV100.3 ENCLOSURE; REQUIRED CHARACTERISTICS
AV100.4 AGREEMENTS TO BUILD; NOTICE OF PROVISIONS
AV100.5 EXEMPT FACILITIES
AV100.7 MODIFICATION AND INTERPRETATION OF DIVISION
692 AV100.8 CONSTRUCTION REQUIREMENTS FOR BUILDING A POOL OR SPA
AV100.9 INFORMATIVE DOCUMENTS
694 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX W – AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
APPENDIX W AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
AW101 GENERAL
AW102 DEFINITIONS
695 AW103 STRUCTURAL STABILITY
AW104 EVACUATION LOCATIONS
AW105 SPACE WITHIN THE BUILDING
696 AW106 DECKS AND BALCONIES THAT ARE EVACUATION LOCATIONS
AW107 ROOFTOP EVACUATION LOCATIONS
AW108 ATTICS THAT ARE EVACUATION LOCATIONS
AW109 ALTERNATE MEANS OF PROTECTION
697 FIGURE K103.1
698 FIGURE K103.1
700 INDEX
706 HISTORY NOTE APPENDIX
708 HELPFUL TOOLS FOR YOUR CALIFORNIA RESIDENTIAL CODE
709 ICC MEMBERSHIP BENEFITS THAT WORK FOR YOU
CA CityofLosAngelesResidentialCode 2017
$87.75