Shopping Cart

No products in the cart.

CA LA CountyFireCode 2011

$81.25

County of Los Angeles Fire Code – Complete Code

Published By Publication Date Number of Pages
CA 2011 739
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

None

PDF Catalog

PDF Pages PDF Title
1 2011 COUNTY OF LOS ANGELES FIRE CODE TITLE 32 OF THE LOS ANGELES COUNTY CODE
2 2011 COUNTY OF LOS ANGELES FIRE CODE TITLE 32 OF THE LOS ANGELES COUNTY CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
5 CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
6 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
8 CALIFORNIA MATRIX ADOPTION TABLES
10 EFFECTIVE USE OF THE INTERNATIONAL FIRE CODE
18 ORDINANCE
20 TABLE OF CONTENTS
30 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND ADMINISTRATION
32 CHAPTER 1 SCOPE AND ADMINISTRATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
34 SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
39 DIVISION II ADMINISTRATION
PART 1—GENERAL PROVISIONS
SECTION 100 CALIFORNIA FIRE CODE AND INTERNATIONAL FIRE CODE ADOPTION BY REFERENCE
SECTION 101 GENERAL
40 SECTION 102 APPLICABILITY
PART 2—ADMINISTRATIVE PROVISIONS
SECTION 103 DEPARTMENT OF FIRE PREVENTION
41 SECTION 104 GENERAL AUTHORITY AND RESPONSIBILITIES
43 SECTION 105 PERMITS
46 TABLE 105.6.8 PERMIT AMOUNTS FOR COMPRESSED GASES
TABLE 105.6.10 PERMIT AMOUNTS FOR CRYOGENIC FLUIDS
48 TABLE 105.6.20 PERMIT AMOUNTS FOR HAZARDOUS MATERIALS
51 SECTION 106 INSPECTIONS
52 SECTION 107 MAINTENANCE
SECTION 108 BOARD OF APPEALS
53 SECTION 109 VIOLATIONS
54 SECTION 110 UNSAFE BUILDINGS
SECTION 111 STOP WORK ORDER
SECTION 112 SERVICE UTILITIES
55 SECTION 113 FEES
56 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
58 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
80 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 3 – GENERAL PRECAUTIONS AGAINST FIRE
82 CHAPTER 3 GENERAL PRECAUTIONS AGAINST FIRE
SECTION 301 GENERAL
SECTION 302 DEFINITIONS
83 SECTION 303 ASPHALT KETTLES
SECTION 304 COMBUSTIBLE WASTE MATERIAL
85 SECTION 305 IGNITION SOURCES
SECTION 306 MOTION PICTURE PROJECTION ROOMS AND FILM
SECTION 307 OPEN BURNING, RECREATIONAL FIRES AND PORTABLE OUTDOOR FIREPLACES
86 SECTION 308 OPEN FLAMES
88 SECTION 309 POWERED INDUSTRIAL TRUCKS AND EQUIPMENT
SECTION 310 SMOKING
89 SECTION 311 VACANT PREMISES
90 SECTION 312 VEHICLE IMPACT PROTECTION
SECTION 313 FUELED EQUIPMENT
SECTION 314 INDOOR DISPLAYS
91 SECTION 315 MISCELLANEOUS COMBUSTIBLE MATERIALS STORAGE
SECTION 316 HAZARDS TO FIRE FIGHTERS
92 SECTION 317 LAUNDRY CARTS
SECTIONS 318-323 RESERVED
SECTION 324 PARADE FLOATS
SECTION 325 CLEARANCE OF BRUSH AND VEGETATIVE GROWTH
95 SECTION 326 ACTIVITIES IN HAZARDOUS FIRE AREAS
97 SECTION 327 ADMINISTRATIVE FINES
98 SECTION 328 LAND DEVELOPMENT AND ENVIRONMENTAL REVIEW FEES
102 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 4 – EMERGENCY PLANNING AND PREPAREDNESS
104 CHAPTER 4 EMERGENCY PLANNING AND PREPAREDNESS
SECTION 401 GENERAL
SECTION 402 DEFINITIONS
SECTION 403 PUBLIC ASSEMBLAGES AND EVENTS
105 SECTION 404 FIRE SAFETY AND EVACUATION PLANS
108 SECTION 405 EMERGENCY EVACUATION DRILLS
109 TABLE 405.2 FIRE AND EVACUATION DRILL FREQUENCY AND PARTICIPATION
SECTION 406 EMPLOYEE TRAINING AND RESPONSE PROCEDURES
110 SECTION 407 HAZARD COMMUNICATION
SECTION 408 USE AND OCCUPANCY-RELATED REQUIREMENTS
114 CALIFORNIA FIRE CODE – MATRIX ADOPTION TABLE CHAPTER 5 – FIRE SERVICE FEATURES
116 CHAPTER 5 FIRE SERVICE FEATURES
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 FIRE APPARATUS ACCESS ROADS
118 SECTION 504 ACCESS TO BUILDING OPENINGS AND ROOFS
SECTION 505 PREMISES IDENTIFICATION
119 SECTION 506 KEY BOXES
SECTION 507 FIRE PROTECTION WATER SUPPLIES
120 SECTION 508 FIRE COMMAND CENTER
SECTION 509 FIRE PROTECTION EQUIPMENT IDENTIFICATION AND ACCESS
121 SECTION 510 EMERGENCY RESPONDER RADIO COVERAGE
SECTION 511 DESTRUCTION OF SIGNS
122 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 6 – BUILDING SERVICES AND SYSTEMS
124 CHAPTER 6 BUILDING SERVICES AND SYSTEMS
SECTION 601 GENERAL
SECTION 602 DEFINITIONS
125 SECTION 603 FUEL-FIRED APPLIANCES
127 SECTION 604 EMERGENCY AND STANDBY POWER SYSTEMS
130 SECTION 605 ELECTRICAL EQUIPMENT, WIRING AND HAZARDS
131 SECTION 606 MECHANICAL REFRIGERATION
133 SECTION 607 ELEVATOR RECALL AND MAINTENANCE
SECTION 608 STATIONARY STORAGE BATTERY SYSTEMS
TABLE 608.1 BATTERY REQUIREMENTS
135 SECTION 609 COMMERCIAL KITCHEN HOODS
TABLE 609.3.3.1 COMMERCIAL COOKING SYSTEM INSPECTION FREQUENCY
136 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 7 – FIRE-RESISTANCE-RATED CONSTRUCTION
138 CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE-RATED CONSTRUCTION
139 SECTION 704 FLOOR OPENINGS AND SHAFTS
140 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
142 CHAPTER 8 INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
143 SECTION 803 INTERIOR WALL AND CEILING FINISH AND TRIM IN EXISTING BUILDINGS
144 TABLE 803.3 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
145 SECTION 804 INTERIOR WALL AND CEILING TRIM IN NEW AND EXISTING BUILDINGS
146 SECTION 805 UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS
148 SECTION 806 DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
149 SECTION 807 DECORATIVE MATERIALS OTHER THAN DECORATIVE VEGETATION IN NEW AND EXISTING BUILDINGS
152 SECTION 808 FURNISHINGS OTHER THAN UPHOLSTERED FURNITURE AND MATTRESSES OR DECORATIVE MATERIALS IN NEW AND EXISTING BUILDINGS
154 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION SYSTEMS
160 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
161 TABLE 901.6.1 FIRE PROTECTION SYSTEM MAINTENANCE STANDARDS
163 SECTION 902 DEFINITIONS
168 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
169 TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS continued
172 TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
178 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
181 SECTION 905 STANDPIPE SYSTEMS
184 SECTION 906 PORTABLE FIRE EXTINGUISHERS
185 TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS
190 TITLE 19, DIVISION 1, SECTION 568, TABLE 2
TITLE 19, DIVISION 1, SECTION 569, TABLE 3
191 TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
TABLE 906.3(2) FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS OF LESS THAN OR EQUAL TO 0.25-INCH
193 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
205 TABLE 907.6.2.3.3 VISIBLE ALARMS
207 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
209 EQUATION 9-1
EQUATION 9-2
210 EQUATION 9-3
213 SECTION 910 SMOKE AND HEAT VENTS
214 TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
215 EQUATION 9-4
SECTION 911 EXPLOSION CONTROL
216 TABLE 911.1 EXPLOSION CONTROL REQUIREMENTS
SECTION 912 FIRE DEPARTMENT CONNECTIONS
217 SECTION 913 FIRE PUMPS
218 SECTION 914 FIRE PROTECTION BASED ON SPECIAL DETAILED REQUIREMENTS OF USE AND OCCUPANCY
220 TABLE 914.8.2 HANGAR FIRE SUPPRESSION REQUIREMENTS
222 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
223 CHAPTER 10 – MEANS OF EGRESS — (Continued)
224 CHAPTER 10 – MEANS OF EGRESS — (Continued)
226 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[B] SECTION 1002 DEFINITIONS
227 [B] SECTION 1003 GENERAL MEANS OF EGRESS
229 [B] SECTION 1004 OCCUPANT LOAD
TABLE 1004.1.1 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
230 [B] SECTION 1005 EGRESS WIDTH
231 [B] SECTION 1006 MEANS OF EGRESS ILLUMINATION
[B] SECTION 1007 ACCESSIBLE MEANS OF EGRESS
234 [B] SECTION 1008 DOORS, GATES AND TURNSTILES
235 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
240 [B] SECTION 1009 STAIRWAYS
243 [B] SECTION 1010 RAMPS
244 [B] SECTION 1011 EXIT SIGNS
246 [B] SECTION 1012 HANDRAILS
247 [B] SECTION 1013 GUARDS
248 [B] SECTION 1014 EXIT ACCESS
250 [B] SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
251 TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
252 [B] SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.1 EXIT ACCESS TRAVEL DISTANCEa
253 [B] SECTION 1017 AISLES
[B] SECTION 1018 CORRIDORS
254 TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
255 [B] SECTION 1019 EGRESS BALCONIES
[B] SECTION 1020 EXITS
[B] SECTION 1021 NUMBER OF EXITS AND CONTINUITY
TABLE 1021.1 MINIMUM NUMBER OF EXITS FOR OCCUPANT LOAD
256 TABLE 1021.2 STORIES WITH ONE EXIT
[B] SECTION 1022 EXIT ENCLOSURES
258 [B] SECTION 1023 EXIT PASSAGEWAYS
259 [B] SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
260 [B] SECTION 1025 HORIZONTAL EXITS
261 [B] SECTION 1026 EXTERIOR EXIT RAMPS AND STAIRWAYS
[B] SECTION 1027 EXIT DISCHARGE
263 [B] SECTION 1028 ASSEMBLY
264 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
266 TABLE 1028.10.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
267 [B] SECTION 1029 EMERGENCY ESCAPE AND RESCUE
269 SECTION 1030 MAINTENANCE OF THE MEANS OF EGRESS
272 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 11 – AVIATION FACILITIES
274 CHAPTER 11 AVIATION FACILITIES
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 GENERAL PRECAUTIONS
SECTION 1104 AIRCRAFT MAINTENANCE
275 SECTION 1105 PORTABLE FIRE EXTINGUISHERS
SECTION 1106 AIRCRAFT FUELING
280 SECTION 1107 HELISTOPS AND HELIPORTS
282 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 12 – DRY CLEANING
284 CHAPTER 12 DRY CLEANING
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 CLASSIFICATIONS
SECTION 1204 GENERAL REQUIREMENTS
285 SECTION 1205 OPERATING REQUIREMENTS
EQUATION 12-1
SECTION 1206 SPOTTING AND PRETREATING
286 SECTION 1207 DRY CLEANING SYSTEMS
SECTION 1208 FIRE PROTECTION
288 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 13 – COMBUSTIBLE DUST-PRODUCING OPERATIONS
290 CHAPTER 13 COMBUSTIBLE DUST-PRODUCING OPERATIONS
SECTION 1301 GENERAL
SECTION 1302 DEFINITIONS
SECTION 1303 PRECAUTIONS
SECTION 1304 EXPLOSION PROTECTION
TABLE 1304.1 EXPLOSION PROTECTION STANDARDS
292 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 14 – FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
294 CHAPTER 14 FIRE SAFETY DURING CONSTRUCTION AND DEMOLITION
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 TEMPORARY HEATING EQUIPMENT
SECTION 1404 PRECAUTIONS AGAINST FIRE
SECTION 1405 FLAMMABLE AND COMBUSTIBLE LIQUIDS
295 SECTION 1406 FLAMMABLE GASES
SECTION 1407 EXPLOSIVE MATERIALS
SECTION 1408 OWNER’S RESPONSIBILITY FOR FIRE PROTECTION
SECTION 1409 FIRE REPORTING
SECTION 1410 ACCESS FOR FIRE FIGHTING
SECTION 1411 MEANS OF EGRESS
296 SECTION 1412 WATER SUPPLY FOR FIRE PROTECTION
SECTION 1413 STANDPIPES
SECTION 1414 AUTOMATIC SPRINKLER SYSTEM
SECTION 1415 PORTABLE FIRE EXTINGUISHERS
SECTION 1416 MOTORIZED EQUIPMENT
SECTION 1417 SAFEGUARDING ROOFING OPERATIONS
298 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 15 – FLAMMABLE FINISHES
300 CHAPTER 15 FLAMMABLE FINISHES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
301 SECTION 1503 PROTECTION OF OPERATIONS
302 SECTION 1504 SPRAY FINISHING
306 SECTION 1505 DIPPING OPERATIONS
307 SECTION 1506 POWDER COATING
308 SECTION 1507 ELECTROSTATIC APPARATUS
309 SECTION 1508 ORGANIC PEROXIDES AND DUAL-COMPONENT COATINGS
SECTION 1509 INDOOR MANUFACTURING OF REINFORCED PLASTICS
310 SECTION 1510 FLOOR SURFACING AND FINISHING OPERATIONS
312 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 16 – FRUIT AND CROP RIPENING (Not adopted by the State Fire Marshal)
314 CHAPTER 16 FRUIT AND CROP RIPENING
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS
SECTION 1603 ETHYLENE GAS
SECTION 1604 SOURCES OF IGNITION
SECTION 1605 COMBUSTIBLE WASTE
SECTION 1606 ETHYLENE GENERATORS
SECTION 1607 WARNING SIGNS
316 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 17 – FUMIGATION AND THERMAL INSECTICIDAL FOGGING (Not adopted by the State Fire Marshal)
318 CHAPTER 17 FUMIGATION AND THERMAL INSECTICIDAL FOGGING
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 FIRE SAFETY REQUIREMENTS
320 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 18 – SEMICONDUCTOR FABRICATION FACILITIES
322 CHAPTER 18 SEMICONDUCTOR FABRICATION FACILITIES
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GENERAL SAFETY PROVISIONS
326 SECTION 1804 STORAGE
327 TABLE 1804.2.2.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
SECTION 1805 USE AND HANDLING
328 TABLE 1804.2.2.1—continued QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
329 TABLE 1805.2.2 MAXIMUM QUANTITIES OF HPM AT A WORKSTATIONd
332 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 19 – LUMBER YARDS AND WOODWORKING FACILITIES
334 CHAPTER 19 LUMBER YARDS AND WOODWORKING FACILITIES
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 GENERAL REQUIREMENTS
335 SECTION 1904 FIRE PROTECTION
SECTION 1905 PLYWOOD, VENEER AND COMPOSITE BOARD MILLS
SECTION 1906 LOG STORAGE AREAS
SECTION 1907 STORAGE OF WOOD CHIPS AND HOGGED MATERIAL ASSOCIATED WITH TIMBER AND LUMBER PRODUCTION FACILITIES
SECTION 1908 STORAGE AND PROCESSING OF WOOD CHIPS, HOGGED MATERIAL, FINES, COMPOST AND RAW PRODUCT ASSOCIATED WITH YARD WASTE AND RECYCLING FACILITIES
336 SECTION 1909 EXTERIOR STORAGE OF FINISHED LUMBER PRODUCTS
SECTION 1910 STORAGE OF COMBUSTIBLE IDLE PALLETS
TABLE 1910.4.1 REQUIRED CLEARANCE BETWEEN OUTSIDE IDLE PALLET STORAGE AND OTHER YARD STORAGE
337 TABLE 1910.4.2 REQUIRED CLEARANCE BETWEEN OUTSIDE IDLE PALLET STORAGE AND STRUCTURES
338 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 20 – MANUFACTURE OF ORGANIC COATINGS
340 CHAPTER 20 MANUFACTURE OF ORGANIC COATINGS
SECTION 2001 GENERAL
SECTION 2002 DEFINITIONS
SECTION 2003 GENERAL PRECAUTIONS
SECTION 2004 ELECTRICAL EQUIPMENT AND PROTECTION
341 SECTION 2005 PROCESS STRUCTURES
SECTION 2006 PROCESS MILLS AND KETTLES
SECTION 2007 PROCESS PIPING
342 SECTION 2008 RAW MATERIALS IN PROCESS AREAS
SECTION 2009 RAW MATERIALS AND FINISHED PRODUCTS
344 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 21 – INDUSTRIAL OVENS
346 CHAPTER 21 INDUSTRIAL OVENS
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS
SECTION 2103 LOCATION
SECTION 2104 FUEL PIPING
SECTION 2105 INTERLOCKS
347 SECTION 2106 FIRE PROTECTION
SECTION 2107 OPERATION AND MAINTENANCE
348 CALIFORNIA FIRE CODE- MATRIX ADOPTION TABLE CHAPTER 22 – MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
350 CHAPTER 22 MOTOR FUEL-DISPENSING FACILITIES AND REPAIR GARAGES
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 LOCATION OF DISPENSING DEVICES
351 SECTION 2204 DISPENSING OPERATIONS
352 SECTION 2205 OPERATIONAL REQUIREMENTS
353 SECTION 2206 FLAMMABLE AND COMBUSTIBLE LIQUID MOTOR FUEL-DISPENSING FACILITIES
354 TABLE 2206.2.3 MINIMUM SEPARATION REQUIREMENTS FOR ABOVE-GROUND TANKS
357 SECTION 2207 LIQUEFIED PETROLEUM GAS MOTOR FUEL-DISPENSING FACILITIES
358 SECTION 2208 COMPRESSED NATURAL GAS MOTOR FUEL-DISPENSING FACILITIES
359 TABLE 2208.8.1.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
SECTION 2209 HYDROGEN MOTOR FUEL-DISPENSING AND GENERATION FACILITIES
360 TABLE 2209.3.1 MINIMUM SEPARATION FOR GASEOUS HYDROGEN DISPENSERS, COMPRESSORS, GENERATORS AND STORAGE VESSELS
362 SECTION 2210 MARINE MOTOR FUEL-DISPENSING FACILITIES
363 TABLE 2209.5.4.3.4 VENT PIPE HEIGHT AND SEPARATION DISTANCE VERSUS HYDROGEN FLOW RATE AND VENT PIPE DIAMETER
FIGURE 2209.5.4.3.4 HYDROGEN VENT PIPE HEIGHT (H) VERSUS DISTANCE (D) REQUIREMENTS
TABLE 2209.5.4.3.6(1) MAXIMUM RADIANT HEAT EXPOSURE
TABLE 2209.5.4.3.6(2) MAXIMUM HYDROGEN CONCENTRATION EXPOSURE
365 SECTION 2211 REPAIR GARAGES
368 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 23 – HIGH-PILED COMBUSTIBLE STORAGE
370 CHAPTER 23 HIGH-PILED COMBUSTIBLE STORAGE
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
371 SECTION 2303 COMMODITY CLASSIFICATION
373 SECTION 2304 DESIGNATION OF HIGH-PILED STORAGE AREAS
SECTION 2305 HOUSEKEEPING AND MAINTENANCE
374 FIGURE 2303.7.4 MIXED COMMODITIES
375 TABLE 2306.2 GENERAL FIRE PROTECTION AND LIFE SAFETY REQUIREMENTS
376 SECTION 2306 GENERAL FIRE PROTECTION AND LIFE SAFETY FEATURES
377 SECTION 2307 SOLID-PILED AND SHELF STORAGE
SECTION 2308 RACK STORAGE
378 TABLE 2308.3 REQUIRED FLUE SPACES FOR RACK STORAGE
SECTION 2309 AUTOMATED STORAGE
379 SECTION 2310 SPECIALTY STORAGE
380 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 24 – TENTS AND OTHER MEMBRANE STRUCTURES
382 CHAPTER 24 TENTS AND OTHER MEMBRANE STRUCTURES
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
383 SECTION 2403 TEMPORARY TENTS AND MEMBRANE STRUCTURES
384 TABLE 2403.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
385 SECTION 2404 TEMPORARY AND PERMANENT TENTS AND MEMBRANE STRUCTURES
390 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 25 – TIRE REBUILDING AND TIRE STORAGE
392 CHAPTER 25 TIRE REBUILDING AND TIRE STORAGE
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 TIRE REBUILDING
SECTION 2504 PRECAUTIONS AGAINST FIRE
SECTION 2505 OUTDOOR STORAGE
393 SECTION 2506 FIRE DEPARTMENT ACCESS
SECTION 2507 FENCING
SECTION 2508 FIRE PROTECTION
394 SECTION 2509 INDOOR STORAGE ARRANGEMENT
396 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 26 – WELDING AND OTHER HOT WORK
398 CHAPTER 26 WELDING AND OTHER HOT WORK
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 GENERAL REQUIREMENTS
399 SECTION 2604 FIRE SAFETY REQUIREMENTS
400 SECTION 2605 GAS WELDING AND CUTTING
SECTION 2606 ELECTRIC ARC HOT WORK
SECTION 2607 CALCIUM CARBIDE SYSTEMS
SECTION 2608 ACETYLENE GENERATORS
401 SECTION 2609 PIPING MANIFOLDS AND HOSE SYSTEMS FOR FUEL GASES AND OXYGEN
402 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 27 – HAZARDOUS MATERIALS—GENERAL PROVISIONS
404 CHAPTER 27 HAZARDOUS MATERIALS—GENERAL PROVISIONS
SECTION 2701 GENERAL
407 TABLE 2703.1.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
408 SECTION 2702 DEFINITIONS
410 TABLE 2703.1.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
411 TABLE 2703.1.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
412 TABLE 2703.1.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
413 TABLE 2703.1.1(3) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD IN AN OUTDOOR CONTROL AREA
414 TABLE 2703.1.1(4) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD IN AN OUTDOOR CONTROL AREA
417 SECTION 2703 GENERAL REQUIREMENTS
418 TABLE 2703.8.2 DETACHED BUILDING REQUIRED
TABLE 2703.8.3.2 DESIGN AND NUMBER OF CONTROL AREAS
422 TABLE 2703.11.1 MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS, NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
424 TABLE 2704.2.2 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL SOLIDS AND LIQUIDS STORAGE
427 SECTION 2704 STORAGE
429 SECTION 2705 USE, DISPENSING AND HANDLING
430 TABLE 2705.2.1.4 REQUIRED SECONDARY CONTAINMENT—HAZARDOUS MATERIAL LIQUIDS USE
434 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 28 – AEROSOLS
436 CHAPTER 28 AEROSOLS
SECTION 2801 GENERAL
SECTION 2802 DEFINITIONS
SECTION 2803 CLASSIFICATION OF AEROSOL PRODUCTS
TABLE 2803.1 CLASSIFICATION OF AEROSOL PRODUCTS
SECTION 2804 INSIDE STORAGE OF AEROSOL PRODUCTS
437 TABLE 2804.3.1 NONSEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 2804.3.2 SEGREGATED STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN GENERAL PURPOSE WAREHOUSES
TABLE 2804.3.2.2 SEGREGATED STORAGE AISLE WIDTHS AND DISTANCE TO AISLES IN GENERAL PURPOSE WAREHOUSES
438 TABLE 2804.7 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL STORAGE AREAS
SECTION 2805 OUTSIDE STORAGE
TABLE 2805.1 DISTANCE TO EXPOSURES FOR OUTSIDE STORAGE OF LEVEL 2 AND 3 AEROSOL PRODUCTS
439 TABLE 2806.4 MAXIMUM STORAGE QUANTITIES FOR STORAGE AREAS ADJACENT TO RETAIL DISPLAY OF LEVEL 2 AND 3 AEROSOLS
SECTION 2806 RETAIL DISPLAY
TABLE 2806.2.1 MAXIMUM QUANTITIES OF LEVEL 2 AND 3 AEROSOL PRODUCTS IN RETAIL DISPLAY AREAS
440 SECTION 2807 MANUFACTURING FACILITIES
442 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 29 – COMBUSTIBLE FIBERS
444 CHAPTER 29 COMBUSTIBLE FIBERS
SECTION 2901 GENERAL
SECTION 2902 DEFINITIONS
SECTION 2903 GENERAL PRECAUTIONS
SECTION 2904 LOOSE FIBER STORAGE
445 SECTION 2905 BALED STORAGE
446 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 30 – COMPRESSED GASES
448 CHAPTER 30 COMPRESSED GASES
SECTION 3001 GENERAL
SECTION 3002 DEFINITIONS
449 SECTION 3003 GENERAL REQUIREMENTS
452 SECTION 3004 STORAGE OF COMPRESSED GASES
SECTION 3005 USE AND HANDLING OF COMPRESSED GASES
453 SECTION 3006 MEDICAL GAS SYSTEMS
SECTION 3007 COMPRESSED GASES NOT OTHERWISE REGULATED
454 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 31 – CORROSIVE MATERIALS
456 CHAPTER 31 CORROSIVE MATERIALS
SECTION 3101 GENERAL
SECTION 3102 DEFINITIONS
SECTION 3103 GENERAL REQUIREMENTS
SECTION 3104 STORAGE
SECTION 3105 USE
458 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 32 – CRYOGENIC FLUIDS
460 CHAPTER 32 CRYOGENIC FLUIDS
SECTION 3201 GENERAL
SECTION 3202 DEFINITIONS
SECTION 3203 GENERAL REQUIREMENTS
462 SECTION 3204 STORAGE
TABLE 3204.3.1.1 SEPARATION OF STATIONARY CONTAINERS FROM EXPOSURE HAZARDS
463 TABLE 3204.3.1.2.1 SEPARATION OF PORTABLE CONTAINERS FROM EXPOSURE HAZARDS
SECTION 3205 USE AND HANDLING
466 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 33 – EXPLOSIVES AND FIREWORKS
468 CHAPTER 33 EXPLOSIVES AND FIREWORKS
SECTION 3301 GENERAL
SECTION 3302 RESERVED
SECTION 3303 RESERVED
SECTION 3304 RESERVED
SECTION 3305 RESERVED
SECTION 3306 RESERVED
SECTION 3307 RESERVED
SECTION 3308 FIREWORKS DISPLAY
469 SECTION 3309 RESERVED
SECTION 3310 SEIZURE OF EXPLOSIVES, EXPLOSIVE MATERIALS, AND FIREWORKS
470 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 34 – FLAMMABLE AND COMBUSTIBLE LIQUIDS
472 CHAPTER 34 FLAMMABLE AND COMBUSTIBLE LIQUIDS
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
473 SECTION 3403 GENERAL REQUIREMENTS
474 TABLE 3403.1.1 CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
475 TABLE 3403.1.1—continued CLASS I ELECTRICAL EQUIPMENT LOCATIONSa
476 TABLE 3403.6.2 PIPING STANDARDS
477 SECTION 3404 STORAGE
487 TABLE 3404.3.4.1 MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIESa
489 TABLE 3404.3.6.3(1) MAXIMUM STORAGE HEIGHT IN CONTROL AREA
490 TABLE 3404.3.6.3(2) STORAGE ARRANGEMENTS FOR PALLETIZED OR SOLID-PILE STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
TABLE 3404.3.6.3(3) STORAGE ARRANGEMENTS FOR RACK STORAGE IN LIQUID STORAGE ROOMS AND WAREHOUSES
491 TABLE 3404.3.6.3(4) AUTOMATIC SPRINKLER PROTECTION FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS AND PORTABLE TANKS
492 TABLE 3404.3.6.3(5) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS WITH OR WITHOUT CARTONS ON CONVENTIONAL WOOD PALLETSa
493 TABLE 3404.3.6.3(6) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
494 TABLE 3404.3.6.3(7) AUTOMATIC AFFF WATER PROTECTION REQUIREMENTS FOR RACK STORAGE OF LIQUIDS IN METAL CONTAINERS GREATER THAN 5-GALLON CAPACITYa
TABLE 3404.3.6.3(8) AUTOMATIC SPRINKLER PROTECTION REQUIREMENTS FOR CLASS I LIQUID STORAGE IN METAL CONTAINERS OF 1-GALLON CAPACITY OR LESS WITH UNCARTONED OR CASE-CUT SHELF DISPLAY UP TO 6.5 FEET, AND PALLETIZED STORAGE ABOVE IN A DOUBLE-ROW RACK ARRAYa
495 TABLE 3404.3.7.5.1 AUTOMATIC AFFF-WATER PROTECTION REQUIREMENTS FOR SOLID-PILE AND PALLETIZED STORAGE OF LIQUIDS IN METAL CONTAINERS OF 5-GALLON CAPACITY OR LESS
496 TABLE 3404.4.2 OUTDOOR LIQUID STORAGE IN CONTAINERS AND PORTABLE TANKS
497 SECTION 3405 DISPENSING, USE, MIXING AND HANDLING
498 TABLE 3405.3.4(1) SEPARATION OF PROCESSING VESSELS FROM LOT LINES
TABLE 3405.3.4(2) REFERENCE TABLE FOR USE WITH TABLE 3405.3.4(1)
501 TABLE 3405.3.8.2 MAXIMUM ALLOWABLE QUANTITIES FOR DISPENSING OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN OUTDOOR CONTROL AREAS
502 SECTION 3406 SPECIAL OPERATIONS
512 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 35 – FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
514 CHAPTER 35 FLAMMABLE GASES AND FLAMMABLE CRYOGENIC FLUIDS
SECTION 3501 GENERAL
SECTION 3502 DEFINITIONS
SECTION 3503 GENERAL REQUIREMENTS
515 SECTION 3504 STORAGE
SECTION 3505 USE
SECTION 3506 FLAMMABLE CRYOGENIC FLUIDS
516 TABLE 3504.2.1 FLAMMABLE GASES—DISTANCE FROM STORAGE TO EXPOSURES
517 SECTION 3507 METAL HYDRIDE STORAGE SYSTEMS
520 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 36 – FLAMMABLE SOLIDS
522 CHAPTER 36 FLAMMABLE SOLIDS
SECTION 3601 GENERAL
SECTION 3602 DEFINITIONS
SECTION 3603 GENERAL REQUIREMENTS
SECTION 3604 STORAGE
SECTION 3605 USE
SECTION 3606 MAGNESIUM
526 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 37 – HIGHLY TOXIC AND TOXIC MATERIALS
528 CHAPTER 37 HIGHLY TOXIC AND TOXIC MATERIALS
SECTION 3701 GENERAL
SECTION 3702 DEFINITIONS
529 SECTION 3703 HIGHLY TOXIC AND TOXIC SOLIDS AND LIQUIDS
530 SECTION 3704 HIGHLY TOXIC AND TOXIC COMPRESSED GASES
532 TABLE 3704.2.2.7.5 RATE OF RELEASE FOR CYLINDERS AND PORTABLE TANKS
534 SECTION 3705 OZONE GAS GENERATORS
536 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 38 – LIQUEFIED PETROLEUM GASES
538 CHAPTER 38 LIQUEFIED PETROLEUM GASES
SECTION 3801 GENERAL
SECTION 3802 DEFINITIONS
SECTION 3803 INSTALLATION OF EQUIPMENT
539 TABLE 3804.3 LOCATION OF LP-GAS CONTAINERS
540 SECTION 3804 LOCATION OF LP-GAS CONTAINERS
SECTION 3805 PROHIBITED USE OF LP-GAS
SECTION 3806 DISPENSING AND OVERFILLING
SECTION 3807 SAFETY PRECAUTIONS AND DEVICES
541 SECTION 3808 FIRE PROTECTION
SECTION 3809 STORAGE OF PORTABLE LP-GAS CONTAINERS AWAITING USE OR RESALE
542 TABLE 3809.12 SEPARATION FROM EXPOSURES OF LP-GAS CONTAINERS AWAITING USE, RESALE OR EXCHANGE STORED OUTSIDE OF BUILDINGS
SECTION 3810 LP-GAS CONTAINERS NOT IN SERVICE
SECTION 3811 PARKING AND GARAGING
544 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 39 – ORGANIC PEROXIDES
546 CHAPTER 39 ORGANIC PEROXIDES
SECTION 3901 GENERAL
SECTION 3902 DEFINITIONS
SECTION 3903 GENERAL REQUIREMENTS
SECTION 3904 STORAGE
547 TABLE 3904.1.2 ORGANIC PEROXIDES—DISTANCE TO EXPOSURES FROM DETACHED STORAGE BUILDINGS OR OUTDOOR STORAGE AREAS
548 TABLE 3904.1.7 STORAGE OF ORGANIC PEROXIDES
SECTION 3905 USE
550 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 40 – OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
552 CHAPTER 40 OXIDIZERS, OXIDIZING GASES AND OXIDIZING CRYOGENIC FLUIDS
SECTION 4001 GENERAL
SECTION 4002 DEFINITIONS
SECTION 4003 GENERAL REQUIREMENTS
553 SECTION 4004 STORAGE
TABLE 4004.1.2 OXIDIZER LIQUIDS AND SOLIDS—DISTANCE FROM DETACHED BUILDINGS AND OUTDOOR STORAGE AREAS TO EXPOSURES
554 TABLE 4004.1.7(1) STORAGE OF CLASS 1 OXIDIZER LIQUIDS AND SOLIDS IN COMBUSTIBLE CONTAINERS
TABLE 4004.1.7(2) STORAGE OF CLASS 2 OXIDIZER LIQUIDS AND SOLIDS
TABLE 4004.1.7(3) STORAGE OF CLASS 3 OXIDIZER LIQUIDS AND SOLIDS
TABLE 4004.1.7(4) STORAGE OF CLASS 4 OXIDIZER LIQUIDS AND SOLIDS
555 TABLE 4004.2.2 OXIDIZER GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 4005 USE
SECTION 4006 LIQUID OXYGEN IN HOME HEALTH CARE
558 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 41 – PYROPHORIC MATERIALS
560 CHAPTER 41 PYROPHORIC MATERIALS
SECTION 4101 GENERAL
SECTION 4102 DEFINITIONS
SECTION 4103 GENERAL REQUIREMENTS
SECTION 4104 STORAGE
561 TABLE 4104.2.1 PYROPHORIC GASES—DISTANCE FROM STORAGE TO EXPOSURESa
SECTION 4105 USE
562 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 42 – PYROXYLIN (CELLULOSE NITRATE) PLASTICS
564 CHAPTER 42 PYROXYLIN (CELLULOSE NITRATE) PLASTICS
SECTION 4201 GENERAL
SECTION 4202 DEFINITIONS
SECTION 4203 GENERAL REQUIREMENTS
SECTION 4204 STORAGE AND HANDLING
566 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 43 – UNSTABLE (REACTIVE) MATERIALS
568 CHAPTER 43 UNSTABLE (REACTIVE) MATERIALS
SECTION 4301 GENERAL
SECTION 4302 DEFINITIONS
SECTION 4303 GENERAL REQUIREMENTS
569 SECTION 4304 STORAGE
SECTION 4305 USE
570 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 44 – WATER-REACTIVE SOLIDS AND LIQUIDS
572 CHAPTER 44 WATER-REACTIVE SOLIDS AND LIQUIDS
SECTION 4401 GENERAL
SECTION 4402 DEFINITIONS
SECTION 4403 GENERAL REQUIREMENTS
SECTION 4404 STORAGE
573 SECTION 4405 USE
574 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 45 – MARINAS
576 CHAPTER 45 MARINAS
SECTION 4501 SCOPE
SECTION 4502 DEFINITIONS
SECTION 4503 GENERAL PRECAUTIONS
SECTION 4504 FIRE PROTECTION EQUIPMENT
577 SECTION 4505 MARINE MOTOR FUEL-DISPENSING FACILITIES
578 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 46 – CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
580 CHAPTER 46 CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS
SECTION 4601 GENERAL
SECTION 4602 DEFINITIONS
SECTION 4603 FIRE SAFETY REQUIREMENTS FOR EXISTING BUILDINGS
581 TABLE 4603.1 OCCUPANCY AND USE REQUIREMENTS
587 SECTION 4604 MEANS OF EGRESS FOR EXISTING BUILDINGS
588 TABLE 4604.7 EGRESS WIDTH PER OCCUPANT SERVED
589 TABLE 4604.10 REVOLVING DOOR SPEEDS
591 TABLE 4604.18.2 COMMON PATH, DEAD-END AND TRAVEL DISTANCE LIMITS (by occupancy)
592 SECTION 4605 REQUIREMENTS FOR OUTDOOR OPERATIONS
SECTION 4606 GROUP A PUBLIC ADDRESS SYSTEM
594 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 47 – REFERENCED STANDARDS
596 CHAPTER 47 REFERENCED STANDARDS
AASHTO
AFSI
API
ASME
597 ASTM
BHMA
598 CA
CGA
CGR
CPSC
599 DOC
DOL
DOTn
DOTy
EN
600 EPA
FCC
FM
ICC
ISO
NEMA
601 NFPA
608 SFM
609 UL
610 USC
612 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 48 – MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUND STAGES, APPROVED PRODUCTION FACILITIES AND PRODUCTION LOCATIONS
614 CHAPTER 48 MOTION PICTURE AND TELEVISION PRODUCTION STUDIO SOUND STAGES, APPROVED PRODUCTION FACILITIES AND PRODUCTION LOCATIONS
SECTION 4801 GENERAL
SECTION 4802 OCCUPANCY CLASSIFICATION
SECTION 4803 REQUIRED PERMITS
615 SECTION 4804 GENERAL REQUIREMENTS
SECTION 4805 FIRE-EXTINGUISHING SYSTEMS
SECTION 4806 FIRE-DETECTION EQUIPMENT
SECTION 4807 FIRE SAFETY OFFICERS
SECTION 4808 ELECTRICAL REQUIREMENTS
616 SECTION 4809 MECHANICAL EQUIPMENT
SECTION 4810 DESIGN REQUIREMENTS
SECTION 4811 PRODUCTION LOCATIONS
618 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE CHAPTER 49 – REQUIREMENTS FOR WILDLAND-URBAN INTERFACE FIRE AREAS
620 CHAPTER 49 REQUIREMENTS FOR WILDLAND-URBAN INTERFACE FIRE AREAS
SECTION 4901 GENERAL
SECTION 4902 DEFINITIONS
SECTION 4903 PLANS [RESERVED]
SECTION 4904 FIRE HAZARD SEVERITY ZONES
SECTION 4905 WILDFIRE PROTECTION BUILDING CONSTRUCTION
621 SECTION 4906 HAZARDOUS VEGETATION AND FUEL MANAGEMENT
SECTION 4907 DEFENSIBLE SPACE
SECTION 4908 FUEL MODIFICATION
624 CHAPTER 50 AUTOMOBILE WRECKING YARDS
SECTION 5001 SCOPE
SECTION 5002 DEFINITION
SECTION 5003 PERMITS
SECTION 5004 FIRE APPARATUS ACCESS ROADS
SECTION 5005 WELDING AND CUTTING
SECTION 5006 HOUSEKEEPING
SECTION 5007 FIRE PROTECTION
SECTION 5008 TIRES
SECTION 5009 BURNING OPERATIONS
SECTION 5010 MOTOR VEHICLE FLUIDS AND HAZARDOUS MATERIALS
626 CHAPTER 51 INFRACTIONS
5101.1 OFFENSES DEEMED INFRACTIONS
627 5101.2 PENALTIES FOR INFRACTIONS
628 CHAPTER 52 CONSOLIDATED FIRE PROTECTION DISTRICT CODE
SECTION 5201 FIRE CODE
SECTION 5202 AREAS REGULATED
SECTION 5203 APPLICABILITY
630 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
632 APPENDIX CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 425 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN GROUPS R-2.1, R-3.1 AND R-4
636 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX A – BOARD OF APPEALS (Not adopted by the State Fire Marshal)
638 APPENDIX A BOARD OF APPEALS
SECTION A101 GENERAL
640 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX B – FIRE-FLOW REQUIREMENTS FOR BUILDINGS
642 APPENDIX B FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION B101 GENERAL
SECTION B102 DEFINITIONS
SECTION B103 MODIFICATIONS
SECTION B104 FIRE-FLOW CALCULATION AREA
SECTION B105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
643 TABLE B105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGSa
644 SECTION B106 REFERENCED STANDARDS
646 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX BB – FIRE-FLOW REQUIREMENTS FOR BUILDINGS
648 APPENDIX BB FIRE-FLOW REQUIREMENTS FOR BUILDINGS
SECTION BB101 SCOPE
SECTION BB102 DEFINITIONS
SECTION BB103 MODIFICATIONS
SECTION BB104 FIRE AREA
SECTION BB105 FIRE-FLOW REQUIREMENTS FOR BUILDINGS
649 TABLE BB105.1 MINIMUM REQUIRED FIRE-FLOW AND FLOW DURATION FOR BUILDINGS
650 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX C – FIRE HYDRANT LOCATIONS AND DISTRIBUTION
652 APPENDIX C FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION C101 GENERAL
SECTION C102 LOCATION
SECTION C103 NUMBER OF FIRE HYDRANTS
SECTION C104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION C105 DISTRIBUTION OF FIRE HYDRANTS
SECTION C106 ON-SITE HYDRANTS
653 TABLE C105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
654 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX CC – FIRE HYDRANT LOCATIONS AND DISTRIBUTION
656 APPENDIX CC FIRE HYDRANT LOCATIONS AND DISTRIBUTION
SECTION CC101 SCOPE
SECTION CC102 LOCATION
SECTION CC103 NUMBER OF FIRE HYDRANTS
SECTION CC104 CONSIDERATION OF EXISTING FIRE HYDRANTS
SECTION CC105 DISTRIBUTION OF FIRE HYDRANTS
657 TABLE CC105.1 NUMBER AND DISTRIBUTION OF FIRE HYDRANTS
658 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX D – FIRE APPARATUS ACCESS ROADS (Not adopted by the State Fire Marshal)
660 APPENDIX D FIRE APPARATUS ACCESS ROADS
SECTION D101 GENERAL
SECTION D102 REQUIRED ACCESS
SECTION D103 MINIMUM SPECIFICATIONS
FIGURE D103.1 DEAD-END FIRE APPARATUS ACCESS ROAD TURNAROUND
TABLE D103.4 REQUIREMENTS FOR DEAD-END FIRE APPARATUS ACCESS ROADS
661 FIGURE D103.6 FIRE LANE SIGNS
SECTION D104 COMMERCIAL AND INDUSTRIAL DEVELOPMENTS
SECTION D105 AERIAL FIRE APPARATUS ACCESS ROADS
SECTION D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
662 SECTION D107 ONE- OR TWO-FAMILY RESIDENTIAL DEVELOPMENTS
D108 REFERENCED STANDARDS
664 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX E – HAZARD CATEGORIES (Not adopted by the State Fire Marshal)
666 APPENDIX E HAZARD CATEGORIES
SECTION E101 GENERAL
SECTION E102 HAZARD CATEGORIES
670 SECTION E103 EVALUATION OF HAZARDS
671 E104 REFERENCED STANDARDS
672 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX F – HAZARD RANKING (Not adopted by the State Fire Marshal)
674 APPENDIX F HAZARD RANKING
SECTION F101 GENERAL
SECTION F102 REFERENCED STANDARDS
675 TABLE F101.2 FIRE FIGHTER WARNING PLACARD DESIGNATIONS BASED ON HAZARD CLASSIFICATION CATEGORIES
676 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX G – CRYOGENIC FLUIDS–WEIGHT AND VOLUME EQUIVALENTS (Not adopted by the State Fire Marshal)
678 APPENDIX G CRYOGENIC FLUIDS—WEIGHT AND VOLUME EQUIVALENTS
SECTION G101 GENERAL
679 TABLE G101.2 WEIGHT AND VOLUME EQUIVALENTS FOR COMMON CRYOGENIC FLUIDS
680 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX H – HAZARDOUS MATERIALS MANAGEMENT PLANS AND HAZARDOUS MATERIALS INVENTORY STATEMENTS
682 APPENDIX H HAZARDOUS MATERIALS MANAGEMENT PLANS AND HAZARDOUS MATERIALS INVENTORY STATEMENTS (See Sections 2701.5.1 and 2701.5.2)
SECTION H1 SCOPE
SECTION H2 HAZARDOUS MATERIALS INVENTORY STATEMENTS (HMIS)
SECTION H3 HAZARDOUS MATERIALS MANAGEMENT PLANS (HMMP)
683 SECTION H4 MAINTENANCE OF RECORDS
684 FIGURE H3 SAMPLE FORMAT HAZARDOUS MATERIALS MANAGEMENT PLAN (HMMP) INSTRUCTIONS
685 FIGURE H3 (Continued)
686 FIGURE H3 (Continued)
687 FIGURE H3 (Continued)
688 FIGURE H3 (Continued)
689 FIGURE H3 (Continued)
690 FIGURE H3 (Continued)
691 FIGURE H3 (Continued)
692 FIGURE H3 (Continued)
693 FIGURE H3 (Continued)
694 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX I – FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS (Not adopted by the State Fire Marshal)
696 APPENDIX I FIRE PROTECTION SYSTEMS—NONCOMPLIANT CONDITIONS
SECTION I101 NONCOMPLIANT CONDITIONS
697 SECTION I102 REFERENCED STANDARDS
698 CALIFORNIA FIRE CODE-MATRIX ADOPTION TABLE APPENDIX J – EMERGENCY RESPONDER RADIO COVERAGE (Not adopted by the State Fire Marshal)
700 APPENDIX J EMERGENCY RESPONDER RADIO COVERAGE
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 TECHNICAL REQUIREMENTS
701 SECTION J104 REFERENCED STANDARDS
702 APPENDIX K ROOF OBSTRUCTIONS
K101.1 SCOPE
K101.2 PERMITS
K101.3 REQUIRED CONSTRUCTION DOCUMENT INFORMATION
K102.1 DEFINITIONS
K103.1 SOLAR PHOTOVOLTAIC SYSTEMS
K103.2 MARKING
703 K103.3 REMOTE ELECTRICAL DISCONNECT
K103.4 ACCESS PATHWAYS AND EMERGENCY VENTILATION
704 K103.5 LOCATION OF CONDUCTORS
K104.1 ROOF GARDENS AND LANDSCAPED ROOFS
K104.2 ACCESS PATHWAYS AND EMERGENCY VENTILATION
705 K104.3 ROOF GARDEN OR LANDSCAPED ROOF MAINTENANCE PLAN
706 APPENDIX L RIFLE RANGE
SECTION 1 PERMIT
1.1 DEFINITION
SECTION 2 SUPERVISION BY RANGE OFFICER
SECTION 3 QUALIFICATIONS OF RANGE OFFICER
SECTION 4 INSPECTION AND DISPOSAL OF AMMUNITION
SECTION 5 PORTABLE FIRE APPLIANCES
SECTION 6 REMOVAL OF VEGETATION
SECTION 7 WARNING
708 APPENDIX M FIRE HAZARD SEVERITY ZONES (FHSZ)
SECTION 1 DESIGNATION
SECTION 2 PERIODIC REVIEW
SECTION 3 DESIGNATION OF INCORPORATED CITIES
SECTION 4 DESIGNATION OF UNINCORPORATED AREAS
4.1 PARCEL IDENTIFICATION
710 INDEX
736 HISTORY NOTE APPENDIX
738 HELPFUL CODE TOOLS FROM ICC
CA LA CountyFireCode 2011
$81.25