Shopping Cart

No products in the cart.

CA LosAngelesCounty BuildingCode Volume 1 2020

$88.29

County of Los Angeles Building Code – Volume 1

Published By Publication Date Number of Pages
CA 2020
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

This package includes 2020 County of Los Angeles amendment pages, and the 2019 California Building Code Title 24, Part 2, Volume 1

PDF Catalog

PDF Pages PDF Title
1 2020 COUNTY OF LOS ANGELES BUILDING CODE VOLUME 1 LOS ANGELES COUNTY CODE TITLE 26 BASED ON THE 2019 CBC AND 2018 IBC®
2 2020 COUNTY OF LOS ANGELES BUILDING CODE VOLUME 1 LOS ANGELES COUNTY CODE TITLE 26 BASED ON THE 2019 CBC AND 2018 IBC® TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
5 CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
6 PREFACE TO THE COUNTY OF LOS ANGELES AMENDMENTS
8 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS OFFICES
10 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
11 CALIFORNIA MATRIX ADOPTION TABLES
16 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
26 TABLE OF CONTENTS
42 CHAPTER 1 ADMINISTRATION
SECTION 100 ADOPTION BY REFERENCE
SECTION 101 TITLE, PURPOSE AND INTENT
43 SECTION 102 UNSAFE BUILDINGS
45 SECTION 103 VIOLATIONS AND PENALTIES
46 SECTION 104 ORGANIZATION AND ENFORCEMENT
48 SECTION 105 APPEALS BOARDS
49 SECTION 106 PERMITS
53 SECTION 107 FEES
58 SECTION 108 INSPECTIONS
59 SECTION 109 USE AND OCCUPANCY
60 SECTION 110 PROHIBITED USES OF BUILDING SITES
64 SECTION 111 ENGINEERING GEOLOGY AND SOILS ENGINEERING REPORTS
SECTION 112 EARTHQUAKE FAULT MAPS
SECTION 113 EARTHQUAKE FAULTS
65 SECTIONS 114 THROUGH 118 RESERVED
SECTION 119 APPLICATION OF STATE AGENCIES
SECTION 1.2 BUILDING STANDARDS COMMISSION
66 SECTION 1.3 BOARD OF STATE AND COMMUNITY CORRECTIONS
67 SECTION 1.4 DEPARTMENT OF CONSUMER AFFAIRS
SECTION 1.5 RESERVED
SECTION 1.6 DEPARTMENT OF FOOD AND AGRICULTURE
SECTION 1.7 CALIFORNIA DEPARTMENT OF PUBLIC HEALTH
68 SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
69 SECTION 1.8.3 LOCAL ENFORCING AGENCY
70 SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
71 SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
SECTION 1.8.8 APPEALS BOARD
72 SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
73 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 DIVISION OF THE STATE ARCHITECT
75 SECTION 1.10 OFFICE OF STATEWIDE HEALTH PLANNING AND DEVELOPMENT
77 SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
81 SECTION 1.12 STATE LIBRARIAN
SECTION 1.13 RESERVED
SECTION 1.14 CALIFORNIA STATE LANDS COMMISSION
82 TABLE 1-A BUILDING PERMIT FEES*1, 2, 3
TABLE 1-B GRADING PERMIT FEES
TABLE 1-C GRADING PLAN CHECK FEES
83 TABLE 1-D LANDSCAPE PERMIT FEES UP TO ONE ACRE
TABLE 1-E LANDSCAPE PLAN CHECK FEES UP TO ONE ACRE
TABLE 1-F CODE ENFORCEMENT FEES
84 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
85 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
86 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
87 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
88 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
89 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued
90 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued
91 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
92 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
93 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
94 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
142 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 3 – OCCUPANCY CLASSIFICATION AND USE
144 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
145 SECTION 304 BUSINESS GROUP B
146 SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
147 SECTION 307 HIGH-HAZARD GROUP H
TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
148 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
149 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARD
150 SECTION 308 INSTITUTIONAL GROUP I
152 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
153 SECTION 311 STORAGE GROUP S
154 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
SECTION 313 LABORATORIES GROUP L [SFM]
SECTION 314 ORGANIZED CAMPS GROUP C [SFM]
156 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
157 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued
158 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued
159 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 4 – SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY—continued
160 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
163 EQUATION 4-1
164 SECTION 403 HIGH-RISE BUILDINGS AND GROUP I-2 OCCUPANCIES HAVING OCCUPIED FLOORS LOCATED MORE THAN 75 FEET ABOVE THE LOWEST LEVEL OF FIRE DEPARTMENT VEHICLE ACCESS
165 TABLE 403.2.4 MINIMUM BOND STRENGTH
167 SECTION 404 ATRIUMS
168 SECTION 405 UNDERGROUND BUILDINGS
169 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
172 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
173 SECTION 407 GROUP I-2
178 SECTION 408 GROUP I-3
184 SECTION 409 MOTION PICTURE PROJECTION ROOMS
SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
186 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
187 SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
189 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
190 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
191 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
192 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
193 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
194 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
195 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
196 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
199 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
204 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
205 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS R-1, R-2, R-2.1, R-2.2, R-3, R-3.1, AND R-4
207 SECTION 421 HYDROGEN FUEL GAS ROOMS
SECTION 422 AMBULATORY CARE FACIILITIES
208 SECTION 423 STORM SHELTERS
SECTION 424 CHILDREN’S PLAY STRUCTURES
209 SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
SECTION 427 MEDICAL GAS SYSTEMS
210 SECTION 435 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-2.1, R-3.1, R-4 [SFM]
213 SECTION 436 GROUP I-4 [SFM]
214 SECTION 437 RESERVED
SECTION 438 RESERVED
SECTION 439 ROAD TUNNELS, BRIDGES, AND OTHER LIMITED-ACCESS HIGHWAYS [SFM]
SECTION 440 HORSE RACING STABLES [SFM]
SECTION 441 PET KENNELS AND PET BOARDING FACILITIES [SFM]
SECTION 442 COMBUSTION ENGINES AND GAS TURBINES [SFM]
SECTION 443 FIXED GUIDEWAY TRANSIT AND PASSENGER RAIL SYSTEMS [SFM]
215 SECTION 444 EXPLOSIVES [SFM]
SECTION 445 RESERVED
SECTION 446 WINERY CAVES [SFM]
216 SECTION 447 RESERVED
SECTION 448 RESERVED
SECTION 449 PUBLIC LIBRARIES [SL AND SFM]
SECTION 450 GROUP C [SFM]
219 SECTION 451 RESERVED
SECTION 452 SCHOOL FACILITIES FOR KINDERGARTEN THROUGH 12TH GRADE AND GROUP E DAY CARE
220 SECTION 453 GROUP L [SFM]
222 TABLE 453.7.2.1 HAZARDOUS MATERIALS QUANTITY PER LABORATORY SUITE
223 SECTION 454 RESERVED
SECTION 455 LARGE FAMILY DAY-CARE HOMES [SFM]
224 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 5 – GENERAL BUILDING HEIGHTS AND AREAS
226 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
227 FIGURE 5-1
SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
228 TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
229 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
230 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
231 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
232 SECTION 506 BUILDING AREA
EQUATION 5-1
EQUATION 5-2
233 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
234 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
235 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEET
236 EQUATION 5-3
EQUATION 5-4
EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
238 SECTION 508 MIXED USE AND OCCUPANCY
240 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 509 INCIDENTAL USES
241 [F] TABLE 509 INCIDENTAL USES
SECTION 510 SPECIAL PROVISIONS
244 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 6 – TYPES OF CONSTRUCTION
246 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
247 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
248 SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
250 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7 – FIRE AND SMOKE PROTECTION FEATURES
252 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
253 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
255 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
256 EQUATION 7-1
257 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-2
258 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
260 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
262 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
263 SECTION 708 FIRE PARTITIONS
265 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
266 SECTION 711 FLOOR AND ROOF ASSEMBLIES
267 SECTION 712 VERTICAL OPENINGS
268 SECTION 713 SHAFT ENCLOSURES
270 SECTION 714 PENETRATIONS
272 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
273 SECTION 716 OPENING PROTECTIVES
274 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
275 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
276 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
280 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
281 TABLE 717.3.2.1 FIRE DAMPER RATING
286 SECTION 718 CONCEALED SPACES
287 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
288 SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
290 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
291 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
292 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
293 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
294 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
295 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
296 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
297 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
298 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
299 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
300 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
301 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
302 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
303 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
304 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
305 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
306 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
307 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
308 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
309 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
310 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
311 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
312 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
313 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
314 EQUATION 7-4
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
315 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
316 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2 (1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
317 FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
318 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
319 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
320 TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
321 EQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
322 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
323 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
324 EQUATION 7-9
EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
325 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
326 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
327 FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-12
EQUATION 7-13
328 EQUATION 7-14
EQUATION 7-15
EQUATION 7-16
329 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
331 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
332 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
333 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
334 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
335 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
336 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
337 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
338 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETE [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETE [FIGURE 722.5.1(6)(c)]
339 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERS [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
340 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
341 TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMING
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
342 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 7A – MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
CHAPTER 7A [SFM] MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION 701A SCOPE, PURPOSE AND APPLICATION
343 SECTION 702A DEFINITIONS
344 SECTION 703A STANDARDS OF QUALITY
345 SECTION 704A IGNITION-RESISTANT CONSTRUCTION
SECTION 705A ROOFING
SECTION 706A VENTS
346 SECTION 707A EXTERIOR COVERING
348 SECTION 708A EXTERIOR WINDOWS, SKYLIGHTS AND DOORS
349 SECTION 709A DECKING
350 SECTION 710A ACCESSORY STRUCTURES
352 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 8 – INTERIOR FINISHES
354 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
356 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
357 SECTION 804 INTERIOR FLOOR FINISH
358 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
359 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
360 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS
361 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
362 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
363 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
364 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
365 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 9 – FIRE PROTECTION AND LIFE SAFETY SYSTEMS—continued
366 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
367 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
369 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
371 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
376 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
378 SECTION 905 STANDPIPE SYSTEMS
381 SECTION 906 PORTABLE FIRE EXTINGUISHERS
382 [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE CALIFORNIA FIRE CODE
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
383 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
397 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
400 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
402 EQUATION 9-1
EQUATION 9-2
408 SECTION 910 SMOKE AND HEAT REMOVAL
409 EQUATION 9-3
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
411 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
412 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
414 SECTION 916 GAS DETECTION SYSTEMS
415 SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER RADIO COVERAGE
416 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS
417 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
418 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
419 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 10 – MEANS OF EGRESS—continued
420 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
422 SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
423 SECTION 1005 MEANS OF EGRESS SIZING
424 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
425 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
427 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 AND R-3 OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
428 TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1008 MEANS OF EGRESS ILLUMINATION
429 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
432 SECTION 1010 DOORS, GATES AND TURNSTILES
434 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
TABLE 1010.1.4.1(2)MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
442 SECTION 1011 STAIRWAYS
446 SECTION 1012 RAMPS
447 SECTION 1013 EXIT SIGNS
448 SECTION 1014 HANDRAILS
450 SECTION 1015 GUARDS
451 SECTION 1016 EXIT ACCESS
452 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
453 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
454 SECTION 1020 CORRIDORS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
455 TABLE 1020.2 MINIMUM CORRIDOR WIDTH
456 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
458 SECTION 1024 EXIT PASSAGEWAYS
459 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
460 SECTION 1026 HORIZONTAL EXITS
461 SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
462 SECTION 1028 EXIT DISCHARGE
463 SECTION 1029 ASSEMBLY
464 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
468 TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
470 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
472 CHAPTER 11 RESERVED
474 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11A – HOUSING ACCESSIBILITY
476 CHAPTER 11A HOUSING ACCESSIBILITY
DIVISION I – APPLICATION, GENERAL PROVISIONS, AND DEFINITIONS
SECTION 1101A APPLICATION
SECTION 1102A BUILDING ACCESSIBILITY
477 SECTION 1103A DESIGN AND CONSTRUCTION
SECTION 1104A COVERED MULTIFAMILY DWELLINGS
478 SECTION 1105A GARAGES, CARPORTS AND PARKING FACILITIES
SECTION 1106A SITE AND BUILDING CHARACTERISTICS
SECTION 1107A DEFINITIONS
479 DIVISION II – EXTERIOR FACILITIES
SECTION 1108A GENERAL REQUIREMENTS FOR ACCESSIBLE PARKING AND EXTERIOR ROUTES OF TRAVEL
SECTION 1109A PARKING FACILITIES
481 SECTION 1110A EXTERIOR ACCESSIBLE ROUTES
482 SECTION 1111A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1112A CURB RAMPS ON ACCESSIBLE ROUTES
SECTION 1113A WALKS AND SIDEWALKS ON ACCESSIBLE ROUTES
483 SECTION 1114A EXTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
484 SECTION 1115A EXTERIOR STAIRWAYS
485 SECTION 1116A HAZARDS ON ACCESSIBLE ROUTES
486 DIVISION III – BUILDING FEATURES
SECTION 1117A GENERAL REQUIREMENTS FOR ACCESSIBLE ENTRANCES, EXITS, INTERIOR ROUTES OF TRAVEL AND FACILITY ACCESSIBILITY
SECTION 1118A EGRESS AND AREAS OF REFUGE
SECTION 1119A INTERIOR ACCESSIBLE ROUTES
487 SECTION 1120A RESERVED
SECTION 1121A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1122A INTERIOR RAMPS AND LANDINGS ON ACCESSIBLE ROUTES
488 SECTION 1123A INTERIOR STAIRWAYS
489 SECTION 1124A ELEVATORS AND PLATFORM (WHEELCHAIR) LIFTS
490 TABLE 1124A.3.2 ELEVATOR CAR DIMENSIONS
491 SECTION 1125A HAZARDS ON ACCESSIBLE ROUTES
492 SECTION 1126A DOORS, GATES AND WINDOWS
494 SECTION 1127A COMMON USE FACILITIES
501 DIVISION IV – DWELLING UNIT FEATURES
SECTION 1128A COVERED DWELLING UNITS
SECTION 1129A RESERVED
SECTION 1130A ACCESSIBLE ROUTE WITHIN COVERED MULTIFAMILY DWELLING UNITS
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
SECTION 1132A DOORS
502 SECTION 1133A KITCHENS
504 SECTION 1134A BATHING AND TOILET FACILITIES
507 SECTION 1135A LAUNDRY ROOMS
SECTION 1136A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
508 DIVISION V – FEATURES COMMON TO EXTERIOR AND INTERIOR OF BUILDINGS
SECTION 1137A OTHER FEATURES AND FACILITIES
SECTION 1138A SPACE ALLOWANCES AND REACH RANGES
510 SECTION 1139A ACCESSIBLE DRINKING FOUNTAINS
511 SECTION 1140A ACCESSIBLE TELEPHONES
SECTION 1141A ACCESSIBLE SWIMMING POOLS
512 SECTION 1142A ELECTRICAL RECEPTACLE, SWITCH AND CONTROL HEIGHTS
SECTION 1143A SIGNAGE
513 TABLE 1143A.5 VISUAL CHARACTER HEIGHT
514 TABLE 1143A.7.1 BRAILLE DIMENSIONS
SECTION 1144A RESERVED
SECTION 1145A RESERVED
SECTION 1146A RESERVED
SECTION 1147A RESERVED
SECTION 1148A RESERVED
SECTION 1149A RESERVED
515 DIVISION VI – SITE IMPRACTICALITY TESTS
SECTION 1150A SITE IMPRACTICALITY TESTS
TEST NO. 1—INDIVIDUAL BUILDING TEST
TEST NO. 2—SITE ANALYSIS TEST
516 TEST NO. 3—UNUSUAL CHARACTERISTICS TEST
517 DIVISION VII – FIGURES
FIGURE 11A-1A INTERNATIONAL ACCESSIBILITY SYMBOL
518 FIGURE 11A-1B HEADROOM CLEARANCE AND OVERHANGING OBSTRUCTION
519 FIGURE 11A-1C WIDTH OF ACCESSIBLE ROUTE AT TURNS
520 FIGURE 11A-1D WHEELCHAIR TURNING SPACE
FIGURE 11A-1E WHEELCHAIR PASSAGE WIDTH
521 FIGURE 11A-1F CHANGE IN LEVEL
522 FIGURE 11A-1G MINIMUM CLEAR FLOOR SPACE FOR WHEELCHAIRS
523 FIGURE 11A-1H MINIMUM CLEAR FLOOR SPACE IN ALCOVES
524 FIGURE 11A-1I FORWARD REACH
525 FIGURE 11A-1J SIDE REACH
526 FIGURE 11A-1K MINIMUM CLEARANCES FOR SEATING AND TABLE
527 FIGURE 11A-1L INTERIOR ACCESSIBLE ROUTE (CORRIDOR) OVER 200 FEET; OCCUPANT LOAD 10 OR MORE
528 FIGURE 11A-2A DOUBLE PARKING STALLS
FIGURE 11A-2B SINGLE AND VAN ACCESSIBLE PARKING STALLS
529 FIGURE 11A-2C DIAGONAL PARKING STALLS
530 FIGURE 11A-3A CURB DETAILS
531 FIGURE 11A-3B CURB DETAIL
532 FIGURE 11A-3C CURB DETAIL
533 FIGURE 11A-3D CURB DETAIL
FIGURE 11A-3E CURB DETAIL
534 FIGURE 11A-3F CURB DETAIL – SIDDEWALK LESS THAN 60″ WIDE
FIGURE 11A-3G CURB DETAIL
535 FIGURE 11A-3H CURB DETAIL
FIGURE 11A-3I CURB DETAIL
536 FIGURE 11A-3J CURB DETAIL
FIGURE 11A-3K CURB DETAIL
537 FIGURE 11A-3L CURB SECTIONS
538 FIGURE 11A-5A RAMPS AND SIDEWALKS
539 FIGURE 11A-6A WARNING STRIPING AND HANDRAIL EXTENSIONS
540 FIGURE 11A-6B HANDRAILS
541 FIGURE 11A-6C RAMP DIMENSIONS
542 FIGURE 11A-6D RAMP LANDING AND DOORWAY
543 FIGURE 11A-6E STAIR HANDRAILS
544 FIGURE 11A-7A MINIMUM DIMENSIONS OF ELEVATOR CARS
545 FIGURE 11A-7B ELEVATOR CONTROL PANEL
546 FIGURE 11A-7C HOISTWAY AND ELEVATOR ENTRANCES
FIGURE 11A-7D GRAPH OF TIMING EQUATION
547 FIGURE 11A-8A MANEUVERING CLEARANCE AT SWINGING DOORS
548 FIGURE 11A-8B MANEUVERING CLEARANCE AT DOORWAYS, SLIDING DOORS, AND FOLDING DOORS
549 FIGURE 11A-8C MANEUVERING CLEARANCES AT RECESSED DOORS
550 FIGURE 11A-8G VESTIBULE
551 FIGURE 11A-8H VESTIBULE (SERVING OTHER THAN A REQUIRED EXIT STAIRWAY)
552 FIGURE 11A-8I THRESHOLDS
FIGURE 11A-8J PLATFORM AT SECONDARY EXTERIOR DOOR
FIGURE 11A-8K RAMP AT SECONDARY EXTERIOR DOOR
553 FIGURE 11A-9A TOILET FACILITIES
554 FIGURE 11A-9B WATER CLOSETS
555 FIGURE 11A-9C GRAB BARS
556 FIGURE 11A-9D KNEE AND TOE SPACE
557 FIGURE 11A-9E CLEAR FLOOR SPACE AT BATHTUBS
558 FIGURE 11A-9F GRAB BARS AT BATHTUBS
559 FIGURE 11A-9G REINFORCEMENT FOR GRAB BARS
560 FIGURE 11A-9H STANDARD ROLL-IN SHOWER
561 FIGURE 1A-9I SHOWER SEATS AND GRAB BARS
562 FIGURE 11A-9J OPEN SHOWER
563 FIGURE 11A-9K ALTERNATE ROLL-IN SHOWER
564 FIGURE 11A-9L SHOWER WITH WATER CLOSET
FIGURE 11A-9M WING WALL OR CABINET AT WATER CLOSET
565 FIGURE 11A-10A KITCHEN SPECIFICATIONS
566 FIGURE 11A-11A DRINKING FOUNTAINS
567 FIGURE 11A-11B TELEPHONES
568 FIGURE 11A-11C INTERNATIONAL TTY SYMBOL
FIGURE 11A-11D VOLUME CONTROL TELEPHONES
FIGURE 11A-11E INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
570 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 11B – ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS,COMMERCIAL BUILDINGS AND PUBLIC HOUSING
572 CHAPTER 11B ACCESSIBILITY TO PUBLIC BUILDINGS, PUBLIC ACCOMMODATIONS, COMMERCIAL BUILDINGS AND PUBLIC HOUSING
DIVISION 1: APPLICATION AND ADMINISTRATION
11B-101 PURPOSE
11B-102 DIMENSIONS FOR ADULTS AND CHILDREN
11B-103 EQUIVALENT FACILITATION
11B-104 CONVENTIONS
FIGURE 11B-104 GRAPHIC CONVENTION FOR FIGURES
11B-105 REFERENCED STANDARDS
11B-106 DEFINITIONS
574 11B-107 SPECIAL CONDITIONS APPEALS ACTION
11B-108 MAINTENANCE OF ACCESSIBLE FEATURES
575 DIVISION 2: SCOPING REQUIREMENTS
11B-201 APPLICATION
11B-202 EXISTING BUILDINGS AND FACILITIES
577 11B-203 GENERAL EXCEPTIONS
578 11B-204 PROTRUDING OBJECTS
11B-205 OPERABLE PARTS
11B-206 ACCESSIBLE ROUTES
583 11B-207 ACCESSIBLE MEANS OF EGRESS
11B-208 PARKING SPACES
TABLE 11B-208.2 PARKING SPACES
584 11B-209 PASSENGER DROP-OFF AND LOADING ZONES AND BUS STOPS
11B-210 STAIRWAYS
585 11B-211 DRINKING FOUNTAINS
11B-212 KITCHENS, KITCHENETTES, WET BARS AND SINKS
11B-213 TOILET FACILITIES AND BATHING FACILITIES
586 11B-214 WASHING MACHINES AND CLOTHES DRYERS
11B-215 FIRE ALARM SYSTEMS AND CARBON MONOXIDE ALARM SYSTEMS
11B-216 SIGNS
588 11B-217 TELEPHONES
TABLE 11B-217.2 WHEELCHAIR ACCESSIBLE TELEPHONES
589 11B-218 TRANSPORTATION FACILITIES
11B-219 ASSISTIVE LISTENING SYSTEMS
590 11B-220 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINTOF SALE DEVICES
11B-221 ASSEMBLY AREAS
TABLE 11B-221.2.1.1 NUMBER OF WHEELCHAIR SPACES IN ASSEMBLY AREAS
592 11B-222 DRESSING, FITTING, AND LOCKER ROOMS
11B-223 MEDICAL CARE AND LONG-TERM CARE FACILITIES
593 11B-224 TRANSIENT LODGING GUEST ROOMS, HOUSING AT A PLACE OF EDUCATION AND SOCIAL SERVICE CENTER ESTABLISHMENTS
TABLE 11B-224.2 GUEST ROOMS WITH MOBILITY FEATURES
594 TABLE 11B-224.4 GUEST ROOMS WITH COMMUNICATION FEATURES
11B-225 STORAGE
595 TABLE 11B-225.3 SELF-SERVICE STORAGE FACILITIES
11B-226 DINING SURFACES AND WORK SURFACES
11B-227 SALES AND SERVICE
TABLE 11B-227.2 CHECK-OUT AISLES
596 11B-228 DEPOSITORIES, VENDING MACHINES, CHANGE MACHINES, MAIL BOXES, FUEL DISPENSERS, AND ELECTRIC VEHICLE CHARGING STATIONS
11B-229 WINDOWS
11B-230 TWO-WAY COMMUNICATION SYSTEMS
11B-231 JUDICIAL FACILITIES
597 TABLE 11B-228.3.2.1 ELECTRIC VEHICLE CHARGING STATIONS FOR PUBLIC USE AND COMMON USE
11B-232 DETENTION FACILITIES AND CORRECTIONAL FACILITIES
598 11B-233 PUBLIC HOUSING FACILITIES
599 11B-234 AMUSEMENT RIDES
600 11B-235 RECREATIONAL BOATING FACILITIES
TABLE 11B-235.2 BOAT SLIPS
11B-236 EXERCISE MACHINES AND EQUIPMENT
11B-237 FISHING PIERS AND PLATFORMS
11B-238 GOLF FACILITIES
11B-239 MINIATURE GOLF FACILITIES
601 11B-240 PLAY AREAS
TABLE 11B-240.2.1.2 NUMBER AND TYPES OF GROUND LEVEL PLAY COMPONENTS REQUIRED TO BE ON ACCESSIBLE ROUTES
11B-241 SAUNAS AND STEAM ROOMS
602 11B-242 SWIMMING POOLS, WADING POOLS, AND SPAS
11B-243 SHOOTING FACILITIES WITH FIRING POSITIONS
11B-244 RELIGIOUS FACILITIES
11B-245 PUBLIC ACCOMMODATIONS LOCATED IN PRIVATE RESIDENCES
11B-246 OUTDOOR DEVELOPED AREAS
603 11B-247 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
11B-248 COMMON USE AREAS AND EMPLOYEE WORK AREAS
11B-249 ADULT CHANGING FACILITIES
604 DIVISION 3: BUILDING BLOCKS
11B-301 GENERAL
11B-302 FLOOR OR GROUND SURFACES
FIGURE 11B-302.2 CARPET PILE HEIGHT
FIGURE 11B-302.3 ELONGATED OPENINGS IN FLOOR OR GROUND SURFACES
11B-303 CHANGES IN LEVEL
FIGURE 11B-303.2 VERTICAL CHANGE IN LEVEL
FIGURE 11B-303.3 BEVELED CHANGE IN LEVEL
11B-304 TURNING SPACE
605 FIGURE 11B-304.3.2 T-SHAPED TURNING SPACE
11B-305 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.3 CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.5 POSITION OF CLEAR FLOOR OR GROUND SPACE
FIGURE 11B-305.7.1 MANEUVERING CLEARANCE IN AN ALCOVE, FORWARD APPROACH
606 FIGURE 11B-305.7.2 MANEUVERING CLEARANCE IN AN ALCOVE, PARALLEL APPROACH
11B-306 KNEE AND TOE CLEARANCE
FIGURE 11B-306.2 TOE CLEARANCE
FIGURE 11B-306.3 KNEE CLEARANCE
607 11B-307 PROTRUDING OBJECTS
FIGURE 11B-307.2 LIMITS OF PROTRUDING OBJECTS
FIGURE 11B-307.3 POST-MOUNTED PROTRUDING OBJECTS
608 FIGURE 11B-307.4 VERTICAL CLEARANCE
FIGURE 11B-307.4.1 GUY BRACES
11B-308 REACH RANGES
FIGURE 11B-308.2.1 UNOBSTRUCTED FORWARD REACH
FIGURE 11B-308.2.2 OBSTRUCTED HIGH FORWARD REACH
609 FIGURE 11B-308.3.1 UNOBSTRUCTED SIDE REACH
FIGURE 11B-308.3.2 OBSTRUCTED HIGH SIDE REACH
TABLE 11B-308.4 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-309 OPERABLE PARTS
610 DIVISION 4: ACCESSIBLE ROUTES
11B-401 GENERAL
11B-402 ACCESSIBLE ROUTES
11B-403 WALKING SURFACES
FIGURE 11B-403.5.1 CLEAR WIDTH OF AN ACCESSIBLE ROUTE
611 FIGURE 11B-403.5.2 CLEAR WIDTH AT TURN
11B-404 DOORS, DOORWAYS, AND GATES
612 FIGURE 11B-404.2.3 CLEAR WIDTH OF DOORWAYS
TABLE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
613 FIGURE 11B-404.2.4.1 MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
614 FIGURE 11B-404.2.4.1—continued MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS AND GATES
615 TABLE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS OR GATES, MANUAL SLIDING DOORS, AND MANUAL FOLDING DOORS
FIGURE 11B-404.2.4.2 MANEUVERING CLEARANCES AT DOORWAYS WITHOUT DOORS, SLIDING DOORS, GATES, AND FOLDING DOORS
616 FIGURE 11B-404.2.4.3 MANEUVERING CLEARANCES AT RECESSED DOORS AND GATES
FIGURE 11B-404.2.6 DOORS IN SERIES AND GATES IN SERIES
618 11B-405 RAMPS
619 FIGURE 11B-405.7 RAMP LANDINGS
FIGURE 11B-405.9.2 CURB OR BARRIER EDGE PROTECTION
11B-406 CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS
620 FIGURE 11B-406.2.2 SIDES OF CURB RAMPS
FIGURE 11B-406.3.2 PARALLEL CURB RAMPS
FIGURE 11B-406.5.3 LANDINGS AT THE TOP OF CURB RAMPS
621 FIGURE 11B-406.5.8 COUNTER SLOPE OF SURFACES ADJACENT TO CURB RAMPS
FIGURE 11B-406.5.10 DIAGONAL OR CORNER TYPE CURB RAMPS
FIGURE 11B-406.6 ISLANDS IN CROSSINGS
11B-407 ELEVATORS
622 FIGURE 11B-407.2.2.2 VISIBLE HALL SIGNALS
623 FIGURE 11B-407.2.3.1 FLOOR DESIGNATIONS ON JAMBS OF ELEVATOR HOISTWAY ENTRANCES
TABLE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
624 FIGURE 11B-407.4.1 ELEVATOR CAR DIMENSIONS
625 TABLE 11B-407.4.7.1.3 ELEVATOR CONTROL BUTTON IDENTIFICATION
626 11B-408 LIMITED-USE/LIMITED-APPLICATION ELEVATORS
627 FIGURE 11B-408.4.1 LIMITED-USE/LIMITED-APPLICATION (LULA) ELEVATOR CAR DIMENSIONS
11B-409 PRIVATE RESIDENCE ELEVATORS
628 FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL
11B-410 PLATFORM LIFTS
FIGURE 11B-410.6 PLATFORM LIFT DOORS AND GATES
11B-411 DESTINATION-ORIENTED ELEVATORS
629 FIGURE 11B-411.2.1.2.3 DESTINATION-ORIENTED ELEVATOR ACCESSIBILITY FUNCTION BUTTON INDICATION
632 FIGURE 11B-411.2.3 FLOOR DESIGNATION AND CAR DESIGNATION SIGNS ON JAMBS OF DESTINATION-ORIENTED ELEVATOR HOISTWAY ENTRANCES
634 DIVISION 5: GENERAL SITE AND BUILDING ELEMENTS
11B-501 GENERAL
11B-502 PARKING SPACES
FIGURE 11B-502.2 VEHICLE PARKING SPACES
635 FIGURE 11B-502.3 PARKING SPACE ACCESS AISLE
636 FIGURE 11B-502.3.3 ANGLED AND PERPENDICULAR PARKING IDENTIFICATION
637 11B-503 PASSENGER DROP-OFF AND LOADING ZONES
FIGURE 11B-503.3 PASSENGER DROP-OFF AND LOADING ZONE ACCESS AISLE
638 11B-504 STAIRWAYS
FIGURE 11B-504.5 STAIR NOSINGS
11B-505 HANDRAILS
639 FIGURE 11B-505.4 HANDRAIL HEIGHT
FIGURE 11B-505.5 HANDRAIL CLEARANCE
FIGURE 11B-505.6 HORIZONTAL PROJECTIONS BELOW GRIPPING SURFACE
FIGURE 11B-505.7.2 HANDRAIL NON-CIRCULAR CROSS SECTION
640 FIGURE 11B-505.10.1 TOP AND BOTTOM HANDRAIL EXTENSION AT RAMPS FIGURE 11B-505.10.2TOP HANDRAIL
FIGURE 11B-505.10.2 TOP HANDRAIL EXTENSION AT STAIRS
FIGURE 11B-505.10.3 BOTTOM HANDRAIL EXTENSION AT STAIRS
641 DIVISION 6: PLUMBING ELEMENTS AND FACILITIES
11B-601 GENERAL
11B-602 DRINKING FOUNTAINS
FIGURE 11B-602.5 DRINKING FOUNTAIN SPOUT LOCATION
11B-603 TOILET AND BATHING ROOMS
642 11B-604 WATER CLOSETS AND TOILET COMPARTMENTS
FIGURE 11B-604.2 WATER CLOSET LOCATION
FIGURE 11B-604.3.1 SIZE OF CLEARANCE AT WATER CLOSETS
FIGURE 11B-604.3.2 (EXCEPTION) OVERLAP OF WATER CLOSET CLEARANCE IN RESIDENTIAL DWELLING UNITS
643 FIGURE 11B-604.5.1 SIDE WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.1 DISPENSER OUTLET LOCATION
FIGURE 11B-604.5.2 REAR WALL GRAB BAR AT WATER CLOSETS
FIGURE 11B-604.7.2 DISPOSAL UNIT LOCATION
644 FIGURE 11B-604.8.1.1.2 MANEUVERING SPACE WITH SIDE-OPENING DOOR
645 FIGURE 11B-604.8.1.1.3 MANEUVERING SPACE WITH END-OPENING DOOR
FIGURE 11B-604.8.1.2 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT DOORS
646 FIGURE 11B-604.8.1.4 WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE CLEARANCE
FIGURE 11B-604.8.2 AMBULATORY ACCESSIBLE TOILET COMPARTMENT
647 TABLE 11B-604.9 SUGGESTED DIMENSIONS FOR CHILDREN’S USE
11B-605 URINALS
FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS
11B-606 LAVATORIES AND SINKS
648 11B-607 BATHTUBS
FIGURE 11B-607.2 CLEARANCE FOR BATHTUBS
649 FIGURE 11B-607.4.1 GRAB BARS FOR BATHTUBS WITH PERMANENT SEATS
FIGURE 11B-607.4.2 GRAB BARS FOR BATHTUBS WITH REMOVABLE IN-TUB SEATS
650 FIGURE 11B-607.5 BATHTUB CONTROL LOCATION
11B-608 SHOWER COMPARTMENTS
FIGURE 11B-608.2.1 TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.2.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
651 FIGURE 11B-608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE
FIGURE 11B-608.3.1 GRAB BARS FOR TRANSFER TYPE SHOWERS
FIGURE 11B-608.3.2 GRAB BARS FOR STANDARD ROLL-IN TYPE SHOWER
FIGURE 11B-608.3.3 GRAB BARS FOR ALTERNATE ROLL-IN TYPE SHOWERS
652 FIGURE 11B-608.5.1 TRANSFER TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.2 STANDARD ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
FIGURE 11B-608.5.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENT CONTROL LOCATION
653 11B-609 GRAB BARS
FIGURE 11B-609.2.2 GRAB BAR NON-CIRCULAR CROSS SECTION
FIGURE 11B-609.3 SPACING OF GRAB BARS
11B-610 SEATS
654 FIGURE 11B-610.2 BATHTUB SEATS
FIGURE 11B-610.3 EXTENT OF SEAT
FIGURE 11B-610.3.1 RECTANGULAR SHOWER SEAT
FIGURE 11B-610.3.2 L-SHAPED SHOWER SEAT
11B-611 WASHING MACHINES AND CLOTHES DRYERS
655 FIGURE 11B-611.4 HEIGHT OF LAUNDRY COMPARTMENT OPENING
11B-612 SAUNAS AND STEAM ROOMS
656 DIVISION 7: COMMUNICATION ELEMENTS AND FEATURES
11B-701 GENERAL
11B-702 FIRE ALARM SYSTEMS
11B-703 SIGNS
FIGURE 11B-703.2.5 HEIGHT OF RAISED CHARACTERS
657 TABLE 11B-703.3.1 BRAILLE DIMENSIONS
FIGURE 11B-703.3.1 BRAILLE MEASUREMENT
FIGURE 11B-703.3.2 POSITION OF BRAILLE
FIGURE 11B-703.4.1 HEIGHT OF TACTILE CHARACTERS ABOVE FINISH FLOOR OR GROUND
658 FIGURE 11B-703.4.2 LOCATION OF TACTILE SIGNS AT DOORS
TABLE 11B-703.5.5 VISUAL CHARACTER HEIGHT
659 FIGURE 11B-703.6.1 PICTOGRAM FIELD
FIGURE 11B-703.7.2.1 INTERNATIONAL SYMBOL OF ACCESSIBILITY
FIGURE 11B-703.7.2.2 INTERNATIONAL SYMBOL OF TTY
FIGURE 11B-703.7.2.3 VOLUME CONTROL TELEPHONE
660 FIGURE 11B-703.7.2.4 INTERNATIONAL SYMBOL OF ACCESS FOR HEARING LOSS
FIGURE 11B-703.7.2.6.4 EDGES AND VERTICES ON GEOMETRIC SYMBOLS
661 TABLE 11B-703.8.4 LOW RESOLUTION VMS CHARACTER HEIGHT
FIGURE 11B-703.8.5 LOW RESOLUTION VMS CHARACTERS
TABLE 11B-703.8.5 PIXEL COUNT FOR LOW RESOLUTION VMS
662 11B-704 TELEPHONES
FIGURE 11B-704.2.1.1 PARALLEL APPROACH TO TELEPHONE
FIGURE 11B-704.2.1.2 FORWARD APPROACH TO TELEPHONE
11B-705 DETECTABLE WARNINGS AND DETECTABLE DIRECTIONAL TEXTURE
663 FIGURE 11B-705.1 SIZE AND SPACING OF TRUNCATED DOMES
664 FIGURE 11B-705.2 DETECTABLE DIRECTIONAL TEXTURE
11B-706 ASSISTIVE LISTENING SYSTEMS
11B-707 AUTOMATIC TELLER MACHINES, FARE MACHINES AND POINT OF SALE DEVICES
665 FIGURE 11B-707.6.2 NUMERIC KEY LAYOUT
666 11B-708 TWO-WAY COMMUNICATION SYSTEMS
667 DIVISION 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
11B-801 GENERAL
11B-802 WHEELCHAIR SPACES, COMPANION SEATS, AND DESIGNATED AISLE SEATS AND SEMI-AMBULANT SEATS
FIGURE 11B-802.1.2 WIDTH OF WHEELCHAIR SPACES
FIGURE 11B-802.1.3 DEPTH OF WHEELCHAIR SPACES
FIGURE 11B-802.2.1.1 LINES OF SIGHT OVER THE HEADS OF SEATED SPECTATORS
FIGURE 11B-802.2.1.2 LINES OF SIGHT BETWEEN THE HEADS OF SEATED SPECTATORS
668 FIGURE 11B-802.2.2.1 LINES OF SIGHT OVER THE HEADS OF STANDING SPECTATORS
FIGURE 11B-802.2.2.2 LINES OF SIGHT BETWEEN THE HEADS OF STANDING SPECTATORS
11B-803 DRESSING, FITTING, AND LOCKER ROOMS
11B-804 KITCHENS, KITCHENETTES, AND WET BARS
669 FIGURE 11B-804.2.1 PASS THROUGH KITCHENS
FIGURE 11B-804.2.2 U-SHAPED KITCHENS
670 11B-805 MEDICAL CARE AND LONG-TERM CARE FACILITIES
671 11B-806 TRANSIENT LODGING GUEST ROOMS
11B-807 HOLDING CELLS AND HOUSING CELLS
672 11B-808 COURTROOMS
11B-809 RESIDENTIAL DWELLING UNITS
673 11B-810 TRANSPORTATION FACILITIES
FIGURE 11B-810.2.2 DIMENSIONS OF BUS BOARDING AND ALIGHTING AREAS
FIGURE 11B-810.3 BUS SHELTERS
674 FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS
11B-811 STORAGE
11B-812 ELECTRIC VEHICLE CHARGING STATIONS
676 FIGURE 11B-812.9 SURFACE MARKING
11B-813 ADULT CHANGING FACILITIES
677 FIGURE 11B-813.2.1.2 CLEARANCE AROUND ADULT CHANGING TABLE
678 DIVISION 9: BUILT-IN ELEMENTS
11B-901 GENERAL
11B-902 DINING SURFACES AND WORK SURFACES
11B-903 BENCHES
FIGURE 11B-903.4 BENCH BACK SUPPORT
11B-904 CHECK OUT AISLES AND SALES AND SERVICE COUNTERS
679 FIGURE 11B-904.3.2 CHECK-OUT AISLE COUNTERS
FIGURE 11B-904.4 (EXCEPTION) ALTERATION OF SALES AND SERVICE COUNTERS
680 DIVISION 10: RECREATION FACILITIES
11B-1001 GENERAL
11B-1002 AMUSEMENT RIDES
FIGURE 11B-1002.4.4.3 PROTRUSIONS IN WHEELCHAIR SPACES IN AMUSEMENT RIDES
681 11B-1003 RECREATIONAL BOATING FACILITIES
682 FIGURE 11B-1003.3.1 BOAT SLIP CLEARANCE
FIGURE 11B-1003.3.1 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOAT SLIPS
FIGURE 11B-1003.3.1 (EXCEPTION 2) EDGE PROTECTION AT BOAT SLIPS
683 FIGURE 11B-1003.3.2 BOARDING PIER CLEARANCE
FIGURE 11B-1003.3.2 (EXCEPTION 1) CLEAR PIER SPACE REDUCTION AT BOARDING PIERS
FIGURE 11B-1003.3.2 (EXCEPTION 2) EDGE PROTECTION AT BOARDING PIERS
11B-1004 EXERCISE MACHINES AND EQUIPMENT
684 11B-1005 FISHING PIERS AND PLATFORMS
FIGURE 11B-1005.3.2 EXTENDED GROUND OR DECK SURFACE AT FISHING PIERS AND PLATFORMS
11B-1006 GOLF FACILITIES
685 11B-1007 MINIATURE GOLF FACILITIES
FIGURE 11B-1007.3.2 GOLF CLUB REACH RANGE AREA
11B-1008 PLAY AREAS
686 FIGURE 11B-1008.3.1 TRANSFER PLATFORMS
687 FIGURE 11B-1008.3.2 TRANSFER STEPS
11B-1009 SWIMMING POOLS, WADING POOLS. AND SPAS
FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION
688 FIGURE 11B-1009.2.3 CLEAR DECK SPACE AT POOL LIFTS
FIGURE 11B-1009.2.4 POOL LIFT SEAT HEIGHT
FIGURE 11B-1009.2.8 POOL LIFT SUBMERGED DEPTH
FIGURE 11B-1009.3.2 SLOPED ENTRY SUBMERGED DEPTH
689 FIGURE 11B-1009.3.3 HANDRAILS FOR SLOPED ENTRY
FIGURE 11B-1009.4.1 CLEAR DECK SPACE AT TRANSFER WALLS
FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT
690 FIGURE 11B-1009.4.3 DEPTH AND LENGTH OF TRANSFER WALLS
FIGURE 11B-1009.4.5 GRAB BARS FOR TRANSFER WALLS
FIGURE 11B-1009.5.1 SIZE OF TRANSFER PLATFORM
FIGURE 11B-1009.5.2 CLEAR DECK SPACE AT TRANSFER PLATFORM
691 FIGURE 11B-1009.5.4 TRANSFER STEPS
FIGURE 11B-1009.5.6 SIZE OF TRANSFER STEPS
FIGURE 11B-1009.5.7 GRAB BARS
11B-1010 SHOOTING FACILITIES WITH FIRING POSITIONS
692 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 12 – INTERIOR ENVIRONMENT
694 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
695 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
697 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
698 SECTION 1205 YARDS OR COURTS
SECTION 1206 SOUND TRANSMISSION
SECTION 1207 INTERIOR SPACE DIMENSIONS
699 SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
700 SECTION 1210 [HCD 1 & HCD 2] GARAGE DOOR SPRINGS
SECTION 1211 [HCD 1] POLLUTANT CONTROL
701 SECTION 1212 RESERVED
SECTION 1213 RESERVED
SECTION 1214 RESERVED
SECTION 1215 RESERVED
SECTION 1216 RESERVED
SECTION 1217 RESERVED
SECTION 1218 RESERVED
SECTION 1219 RESERVED
SECTION 1220 RESERVED
SECTION 1221 RESERVED
SECTION 1222 RESERVED
SECTION 1223 RESERVED
SECTION 1224 [OSHPD 1 & OSHPD 1R] HOSPITALS
707 TABLE 1224.4.6.1 STATION OUTLETS FOR OXYGEN, VACUUM (SUCTION), AND MEDICAL AIR SYSTEMS1
708 TABLE 1224.4.6.5 [OSHPD 1, 1R, 2, 3, 4 & 5] LOCATION OF NURSE CALL DEVICES • = Required
710 TABLE 1224.4.11 ACCEPTABLE CEILING AND CARPET LOCATIONS
713 TABLE 1224.4.19 SOUND TRANSMISSION LIMITATIONS IN HOSPITALS
748 SECTION 1225 [OSHPD 2] SKILLED NURSING AND INTERMEDIATE-CARE FACILITIES
757 SECTION 1226 [OSHPD 3] CLINICS
769 SECTION 1227 [OSHPD 4] CORRECTIONAL TREATMENT CENTERS
774 SECTION 1228 [OSHPD 5] ACUTE PSYCHIATRIC HOSPITALS
779 SECTION 1229 RESERVED
SECTION 1230 [BSCC] MINIMUM STANDARDS FOR JUVENILE FACILITIES
781 TABLE 1230A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
784 SECTION 1231 [BSCC] LOCAL DETENTION
787 TABLE 1231A REQUIRED SPACES AND EQUIPMENT IN JUVENILE FACILITIES
789 SECTION 1232 RESERVED
SECTION 1233 RESERVED
SECTION 1234 RESERVED
SECTION 1235 [DPH] SANITARY CONTROL OF SHELLFISH (PLANTS AND OPERATIONS)
790 SECTION 1236 [DPH] LABORATORY ANIMAL QUARTERS
SECTION 1237 [DPH] WILD ANIMAL QUARANTINE FACILITIES
791 SECTION 1238 RESERVED
SECTION 1239 RESERVED
SECTION 1240 [AGR] MEAT AND POULTRY PROCESSING PLANTS
792 TABLE 1240.15.1
SECTION 1241 [AGR] COLLECTION CENTERS AND FACILITIES
793 SECTION 1242 [AGR] RENDERERS
SECTION 1243 [AGR] HORSEMEAT AND PET FOOD ESTABLISHMENTS
794 SECTION 1244 RESERVED
SECTION 1245 RESERVED
SECTION 1246 RESERVED
SECTION 1247 RESERVED
SECTION 1247 RESERVED
SECTION 1248 RESERVED
SECTION 1249 RESERVED
SECTION 1250 [CA] PHARMACIES
SECTION 1251 [CA] VETERINARY FACILITIES
795 SECTION 1252 [CA] BARBER COLLEGES AND SHOPS
SECTION 1253 [CA] SCHOOLS OF COSMETOLOGY, COSMETOLOGICAL ESTABLISHMENTS AND SATELLITE CLASSROOMS
SECTION 1254 [CA] ACUPUNCTURE OFFICES
796 CHAPTER 13 ENERGY EFFICIENCY Refer to California Energy Code, Title 24, Part 6
798 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 14 – EXTERIOR WALLS
800 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
801 SECTION 1403 MATERIALS
SECTION 1404 INSTALLATION OF WALL COVERINGS
802 TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
803 TABLE 1404.3.2 CLASS III VAPOR RETARDERS
807 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
808 TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
809 TABLE 1406.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
810 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
811 SECTION 1409 PLASTIC COMPOSITE DECKING
812 SECTION 1410 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] ADDITIONAL REQUIREMENTS FOR ANCHORED AND ADHERED VENEER
814 CALIFORNIA BUILDING CODE – MATRIX ADOPTION TABLE CHAPTER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
816 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
SECTION 1504 PERFORMANCE REQUIREMENTS
817 TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D316 OR D71581
818 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
819 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
820 TABLE 1507.1.1(1) UNDERLAYMENT TYPES
821 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
822 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
823 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
824 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
825 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
826 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
827 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
828 TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
829 TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
830 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
831 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
832 SECTION 1510 ROOFTOP STRUCTURES
834 SECTION 1511 REROOFING
835 SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
SECTION 1513 [DSA-SS & DSA-SS/CC, OSHPD 1, 1R, 2, 4 & 5] SEISMIC ANCHORAGE OF SLATE SHINGLE, CLAY AND CONCRETE TILE ROOF COVERINGS
836 INDEX
878 HISTORY NOTE APPENDIX
880 HELPFUL TOOLS FOR YOUR CALIFORNIA BUILDING CODE
881 ICC MEMBERSHIP
CA LosAngelesCounty BuildingCode Volume 1 2020
$88.29