1 2020 COUNTY OF LOS ANGELES RESIDENTIAL CODE LOS ANGELES COUNTY CODE TITLE 30 BASED ON THE 2019 CRC AND 2018 IRC®
2 2020 COUNTY OF LOS ANGELES RESIDENTIAL CODE LOS ANGELES COUNTY CODE TITLE 30 BASED ON THE 2019 CRC AND 2018 IRC® TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
5 CALIFORNIA CODE OF REGUALTIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
6 PREFACE TO THE COUNTY OF LOS ANGELES AMENDMENTS
8 COUNTY OF LOS ANGELES DEPARTMENT OF PUBLIC WORKS OFFICES
10 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
12 CALIFORNIA MATRIX ADOPTION TABLES
16 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
26 TABLE OF CONTENTS
30 CHAPTER 1 ADMINISTRATION
SECTION R100 ADOPTION BY REFERENCE
SECTION R101 TITLE, PURPOSE, AND INTENT
42 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
43 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued
44 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
45 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
46 PART II—DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
60 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING
61 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING—continued
62 PART III—BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 SITE DRAINAGE
SECTION R301 DESIGN CRITERIA
65 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
66 TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
67 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
68 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) (psf)
69 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE R301.2(1) ISOLINES OF THE 97 1/2 -PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
70 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES
71 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
72 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
73 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
74 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
75 FIGURE R301.2(3) ALTERNATE SEISMIC DESIGN CATEGORIES
76 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
77 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
78 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
79 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
80 FIGURE R301.2(4) WEATHERING PROBABILITY MAP FOR CONCRETE
81 FIGURE R301.2(5)A ULTIMATE DESIGN WIND SPEEDS
82 FIGURE R301.2(5)B REGIONS WHERE WIND DESIGN IS REQUIRED
FIGURE R301.2(5) BREGIONS WHERE WIND DESIGN IS REQUIRED
83 FIGURE R301.2(6) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
84 FIGURE R301.2(6)—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
85 FIGURE R301.2(7) TERMITE INFESTATION PROBABILITY MAP
86 FIGURE R301.2(8) COMPONENT AND CLADDING PRESSURE ZONES
TABLE R301.2.1.3 WIND SPEED CONVERSIONS
87 TABLE R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
88 FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION
90 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
91 TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS
SECTION R302 FIRE-RESISTANT CONSTRUCTION
92 TABLE R302.1(1) EXTERIOR WALLS
TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS AND ACCESSORY BUILDINGS WITH AUTOMATIC RESIDENTIAL FIRE SPRINKLER PROTECTION
95 TABLE R302.6 DWELLING-GARAGE AND/OR CARPORT SEPARATION
97 SECTION R303 LIGHT, VENTILATION AND HEATING
98 SECTION R304 MINIMUM ROOM AREAS
99 SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
100 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
101 FIGURE R308.4.7 HAZARDOUS GLAZING LOCATIONS AT BOTTOM STAIR LANDINGS
102 SECTION R309 GARAGES AND CARPORTS
103 SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
105 SECTION R311 MEANS OF EGRESS
108 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
109 SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
110 TABLE R313.3.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
111 FIGURE R313.3.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
113 EQUATION 29-1
114 TABLE R313.3.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
115 TABLE R313.3.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
TABLE R313.3.6.2(3) ELEVATION LOSS (PLe)
116 TABLE R313.3.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
117 TABLE R313.3.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
118 TABLE R313.3.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
119 TABLE R313.3.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
120 TABLE R313.3.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
121 TABLE R313.3.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
122 SECTION R314 SMOKE ALARMS
126 SECTION R315 CARBON MONOXIDE ALARMS
127 SECTION R316 FOAM PLASTIC
130 SECTION R317 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS AGAINST DECAY
131 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
132 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY
SECTION R321 ELEVATORS AND PLATFORM LIFTS
SECTION R322 FLOOD-RESISTANT CONSTRUCTION
136 SECTION R323 STORM SHELTERS
SECTION 324 SOLAR ENERGY SYSTEMS
137 SECTION R325 MEZZANINES
138 SECTION R326 RESERVED
SECTION R327 STATIONARY STORAGE BATTERY SYSTEMS
SECTION R334 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING
SECTION R335 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-3.1
142 SECTION R336 LARGE FAMILY DAY-CARE HOMES
143 SECTION R337 MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION R337.1 SCOPE, PURPOSE AND APPLICATION
144 SECTION R337.2 DEFINITIONS
145 SECTION R337.3 STANDARDS OF QUALITY
146 SECTION R337.4 IGNITION-RESISTANT CONSTRUCTION
SECTION R337.5 ROOFING
147 SECTION R337.6 VENTS
SECTION R337.7 EXTERIOR COVERING
150 SECTION R337.8 EXTERIOR WINDOWS, SKYLIGHTS AND DOORS
151 SECTION R337.9 DECKING
SECTION R337.10 ACCESSORY STRUCTURES
152 SECTION R338 ELECTRIC VEHICLE
SECTION R340 POLLUTANT CONTROL
154 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 4 – FOUNDATIONS
156 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
157 SECTION R402 MATERIALS
158 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
159 TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION (inches)a, b
160 TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER
161 TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE CONCRETE OR FULLY GROUTED MASONRY WALL CONSTRUCTION
162 FIGURE R403.1(1) PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SDC A, B AND C
163 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
164 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
165 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEM WALLS IN SDC D0, D1 AND D2
167 FIGURE R403.1.5 STEPPED FOOTING
168 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
169 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
170 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
171 TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
172 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
173 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
174 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
175 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
176 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
177 TABLE R403.4 MINIMUM DEPTH (D) AND WIDTH (W) OF CRUSHED STONE FOOTINGSa, b (inches)
178 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
SECTION R404 FOUNDATION AND RETAINING WALLS
179 TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLSf
180 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  5 INCHES
181 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  6.75 INCHES
182 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  8.75 INCHES
183 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
184 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS
185 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
186 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS
187 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS
188 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS
189 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10- AND 12-INCH NOMINAL FLAT BASEMENT WALLS
190 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND ALTERNATE GRADE OF STEEL
195 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
197 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
SECTION R405 FOUNDATION DRAINAGE
198 TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
199 SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING
SECTION R407 COLUMNS
200 SECTION R408 UNDER-FLOOR SPACE
202 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 5 – FLOORS
204 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
205 FIGURE R502.2 FLOOR CONSTRUCTION
206 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
207 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
208 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
209 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
211 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY
212 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
213 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT
214 TABLE R503.2.1.1(1)–continued ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENTa, b, c
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVE- TREATED WOOD FLOORS (ON GROUND)
215 FIGURE R503.2.4 OPENING IN HORIZONTAL DIAPHRAGMS
SECTION R505 COLD-FORMED STEEL FLOOR FRAMING
216 FIGURE R505.1.2 IN-LINE FRAMING
217 TABLE R505.2.3 COLD-FORMED STEEL JOIST SIZES AND THICKNESS
FIGURE R505.2.3(1) C-SHAPED SECTION
FIGURE R505.2.3(2) TRACK SECTION
218 FIGURE R505.2.6.1 FLOOR JOIST WEB HOLES
FIGURE R505.2.6.3 FLOOR JOIST WEB HOLE PATCH
219 TABLE R505.3.1(1) FLOOR-TO-FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
FIGURE R505.3.1(1) FLOOR-TO-EXTERIOR LOAD-BEARING WALL STUD CONNECTION
221 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(2) FLOOR-TO-WOOD-SILL CONNECTION
222 FIGURE R505.3.1(3) FLOOR-TO-FOUNDATION CONNECTION
FIGURE R505.3.1(4) CANTILEVERED FLOOR-TO-FOUNDATION CONNECTION
223 FIGURE R505.3.1(5) CANTILEVERED FLOOR-TO-WOOD-SILL CONNECTION
FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
224 FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
225 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
226 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE OR CONTINUOUS SPAN
SECTION R506 CONCRETE FLOORS (ON GROUND)
227 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
228 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
FIGURE R505.3.4(2) BEARING STIFFENER
229 FIGURE R505.3.7 TRACK SPLICE
FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING
230 FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
231 FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
SECTION R507 EXTERIOR DECKS
232 TABLE R507.2.3 FASTENER AND CONNECTOR SPECIFICATIONS FOR DECKS
TABLE R507.4 DECK POST HEIGHTa
233 FIGURE R507.3 DECK POSTS TO DECK FOOTING CONNECTION
234 TABLE R507.3.1 MINIMUM FOOTING SIZE FOR DECKS
235 FIGURE R507.5 TYPICAL DECK JOIST SPANS
TABLE R507.5 DECK BEAM SPAN LENGTHS (feet – inches)
236 FIGURE R507.5.1(1) DECK BEAM TO DECK POST
FIGURE R507.5.1(2) NOTCHED POST-TO-BEAM CONNECTION
237 FIGURE R507.6 TYPICAL DECK JOIST SPANS
238 TABLE R507.6 DECK JOIST SPANS FOR COMMON LUMBER SPECIES (ft. – in.)
TABLE R507.7 MAXIMUM JOIST SPACING FOR DECKING
239 TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOIST (Deck live load = 40 psf, deck dead load = 10 psf, snow load ≤ 40 psf)
240 TABLE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
FIGURE R507.9.1.3(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
FIGURE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
241 FIGURE R507.9.2(1) DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R507.9.2(2) DECK ATTACHMENT FOR LATERAL LOADS
242 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 6 – WALL CONSTRUCTION
244 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
245 TABLE R602.3(1) FASTENING SCHEDULE
246 TABLE R602.3(1)—continued FASTENING SCHEDULE
247 TABLE 602.3(1) FASTENING SCHEDULE—continued
248 TABLE R602.3(1)—continued FASTENING SCHEDULE
249 TABLE R602.3.2 SINGLE TOP-PLATE SPLICE CONNECTION DETAILS
250 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
251 TABLE R602.3(2)—continued ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
252 TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
TABLE R602.3(6) ALTERNATE WOOD BEARING WALL STUD SIZE, HEIGHT AND SPACING
253 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
254 FIGURE R602.3(2) FRAMING DETAILS
255 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
256 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
257 TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
258 TABLE R602.7(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
259 TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R602.7(3) GIRDER AND HEADER SPANSa FOR OPEN PORCHES (Maximum span for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb)
260 FIGURE R602.7.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
FIGURE R602.7.2 RIM BOARD HEADER CONSTRUCTION
261 TABLE R602.7.5 MINIMUM NUMBER OF FULL-HEIGHT STUDS AT EACH END OF HEADERS IN EXTERIOR WALLSa
262 TABLE R602.7.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
263 FIGURE R602.10.1.1 BRACED WALL LINES
TABLE R602.10.1.3 BRACED WALL LINE SPACING
264 FIGURE R602.10.1.4 ANGLED WALLS
FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
266 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
267 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
268 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
269 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
270 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
271 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
272 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
273 TABLE R602.10.4 BRACING METHODS
274 TABLE R602.10.4—continued BRACING METHODS
276 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
277 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
278 FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS AT DETACHED GARAGE DOOR OPENINGS
279 FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
280 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
281 TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELSa
282 TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
283 FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
284 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
285 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
286 FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
287 FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
288 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
289 FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
290 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
291 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
292 FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
SECTION R603 COLD-FORMED STEEL WALL FRAMING
293 FIGURE R603.1.2 IN-LINE FRAMING
294 FIGURE R603.2.3(1) C-SHAPED SECTION
FIGURE R603.2.3(2) TRACK SECTION
TABLE R603.2.3 LOAD-BEARING COLD-FORMED STEEL STUD SIZES AND THICKNESSES
295 FIGURE R603.2.6.1 WALL STUD WEB HOLES
FIGURE R603.2.6.3 WALL STUD WEB HOLE PATCH
296 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS
297 TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS
FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
298 FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
299 FIGURE R603.3.1(4) WIND UPLIFT CONNECTOR
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
300 TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
301 TABLE R603.3.2(3) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
302 TABLE R603.3.2(4) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
303 TABLE R603.3.2(5) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
304 TABLE R603.3.2(6) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
305 TABLE R603.3.2(7) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
306 TABLE R603.3.2(8) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
307 TABLE R603.3.2(9) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
308 TABLE R603.3.2(10) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
309 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
310 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
311 TABLE R603.3.2(13) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
312 TABLE R603.3.2(14) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
313 TABLE R603.3.2(15) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
314 TABLE R603.3.2(16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
315 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHT
316 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT
317 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
318 FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
319 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
320 TABLE R603.6(1) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
321 TABLE R603.6(2) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
322 TABLE R603.6(3) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
323 TABLE R603.6(4) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
324 TABLE R603.6(5) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
325 TABLE R603.6(6) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
326 FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
327 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTS
TABLE R603.8 HEAD AND SILL TRACK SPAN
328 FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
329 TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS
TABLE R603.9.2(2) FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
FIGURE R603.9.4.2 CORNER STUD HOLD-DOWN DETAIL
330 TABLE R603.9.5(1) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
331 TABLE R603.9.5(2) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
332 TABLE R603.9.5(3) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
333 TABLE R603.9.5(4) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
334 TABLE R606.2.8 MORTAR PROPORTIONS
335 TABLE R606.2.12 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
336 TABLE R606.3.4.1 MINIMUM CORROSION PROTECTION
TABLE R606.3.5.1 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
338 TABLE R606.6.4 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
339 TABLE R606.9 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
340 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
341 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
342 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D2
343 TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
344 TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
345 SECTION R607 GLASS UNIT MASONRY
346 FIGURE R607.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
347 SECTION R608 EXTERIOR CONCRETE WALL CONSTRUCTION
348 TABLE R608.3 DIMENSIONAL REQUIREMENTS FOR WALLSa
FIGURE R608.3(1) FLAT WALL SYSTEM
349 FIGURE R608.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R608.3(3) SCREEN-GRID WALL SYSTEM
351 TABLE R608.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R608.5.4(1) LAP SPLICES
352 FIGURE R608.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION6 d BENDDIAMETERbdb12 dEXTENSIONbdb6 d BENDDIAMETERb2 / IN., BUT NOTLESS THAN 4 d EXTENSION12bdb4 d
FIGURE R608.5.4(3) STANDARD HOOKS
353 TABLE R608.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND ALTERNATIVE GRADE OF STEEL
355 FIGURE R608.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R608.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST STORY AND LIGHT-FRAMED SECOND STORY
FIGURE R608.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
356 TABLE R608.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS
357 TABLE R608.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS
358 TABLE R608.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS
359 TABLE R608.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS
361 EQUATION R6-1
EQUATION R6-2
362 TABLE R608.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY
363 TABLE R608.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY
364 TABLE R608.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY
365 TABLE R608.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY
366 TABLE R608.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
367 TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
368 TABLE R608.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R608.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEET
369 TABLE R608.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLS
370 FIGURE R608.7(1) MINIMUM SOLID WALL LENGTH
371 FIGURE R608.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
372 FIGURE R608.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
373 FIGURE R608.8(1) REINFORCEMENT OF OPENINGS
374 FIGURE R608.8(2) LINTEL FOR FLAT WALLS
375 FIGURE R608.8(3) LINTELS FOR WAFFLE-GRID WALLS
376 FIGURE R608.8(4) LINTELS FOR SCREEN-GRID WALLS
377 TABLE R608.8(1) LINTEL DESIGN LOADING CONDITIONS
378 TABLE R608.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
379 TABLE R608.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
380 TABLE R608.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
381 TABLE R608.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
382 TABLE R608.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
383 TABLE R608.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
384 TABLE R608.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
385 TABLE R608.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
386 TABLE R608.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
387 TABLE R608.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
388 TABLE R608.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
389 TABLE R608.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
390 TABLE R608.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
391 TABLE R608.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
392 TABLE R608.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
TABLE R608.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
394 FIGURE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
395 TABLE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
396 FIGURE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
397 TABLE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
398 FIGURE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING, PERPENDICULAR
399 TABLE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
400 FIGURE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
401 TABLE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
402 FIGURE R608.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
403 TABLE R608.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
404 FIGURE R608.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
405 TABLE R608.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
406 FIGURE R608.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
407 TABLE R608.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
408 FIGURE R608.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
409 TABLE R608.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
410 FIGURE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
411 TABLE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
412 FIGURE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
413 TABLE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
414 FIGURE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
415 TABLE R608.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
416 FIGURE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
417 TABLE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
418 SECTION R609 EXTERIOR WINDOWS AND DOORS
419 FIGURE R609.7.2(1) THROUGH THE FRAME
FIGURE R609.7.2(2) FRAME CLIP
FIGURE R609.7.2(3) THROUGH THE FRAME
FIGURE R609.7.2(4) FRAME CLIP
420 FIGURE R609.7.2(5) THROUGH THE FLANGE
FIGURE R609.7.2(6) THROUGH THE FLANGE
FIGURE R609.7.2(7) FRAME CLIP
FIGURE R609.7.2(8) THROUGH THE FLANGE
421 SECTION R610 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
422 FIGURE R610.4 SIP WALL PANEL
423 TABLE R610.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches)a
424 TABLE R610.5(2) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF ONLY (inches)a
425 FIGURE R610.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R610.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
426 FIGURE R610.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R610.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
427 FIGURE R610.5(5) SIP WALL-TO-WALL HANGING FLOOR FRAME CONNECTION
FIGURE R610.5.1 SIP WALL FRAMING CONFIGURATION
428 FIGURE R610.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R610.5.4 SIP CORNER FRAMING DETAIL
429 FIGURE R610.8 TYPICAL SIP WALL PANEL-TO-PANEL CONNECTION DETAILS
TABLE R610.8 MAXIMUM SPANS FOR 11 7/8-INCH OR DEEPER SIP HEADERS
430 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 7 – WALL COVERING
432 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
433 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
435 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
436 TABLE R702.3.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE R702.4.2 BACKER BOARD MATERIALS
437 SECTION R703 EXTERIOR COVERING
438 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
439 TABLE R703.3(1)—continued SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
440 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTION
TABLE R703.3.2 LIMITS FOR ATTACHMENT PER TABLE R703.3(1)
TABLE R703.3.3 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
442 TABLE R703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLS
443 TABLE R703.6.3(1) SINGLE-COURSE SIDEWALL FASTENERS
TABLE R703.6.3(2) DOUBLE-COURSE SIDEWALL FASTENERS
444 FIGURE R703.8 TYPICAL MASONRY VENEER WALL DETAILSe
445 FIGURE R703.8—continued TYPICAL MASONRY VENEER WALL DETAILSe
446 TABLE R703.8(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.8(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
447 FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
448 TABLE R703.8.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER
TABLE R703.8.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
FIGURE R703.8.3.2 MASONRY VENEER OPENING
449 TABLE R703.8.4(1) TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
450 TABLE R703.8.4(2) REQUIRED BRICK TIE SPACING FOR DIRECT APPLICATION TO WOOD STRUCTURAL PANEL SHEATHING
452 TABLE R703.11.2 ADJUSTED MINIMUM DESIGN WIND PRESSURE REQUIREMENT FOR VINYL SIDING
453 TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
454 TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
TABLE R703.16.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
455 TABLE R703.16.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
456 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 8 – ROOF-CEILING CONSTRUCTION
458 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
460 TABLE R802.4.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
461 TABLE R802.4.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
462 TABLE R802.4.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
463 TABLE R802.4.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
464 TABLE R802.4.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
465 TABLE R802.4.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
466 TABLE R802.4.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
467 TABLE R802.4.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
468 TABLE R802.4.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
469 TABLE R802.4.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
470 TABLE R802.4.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
471 TABLE R802.4.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
472 TABLE R802.4.1(7) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
473 TABLE R802.4.1(7)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
474 TABLE R802.4.1(8) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
475 TABLE R802.4.1(8)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
476 FIGURE R802.4.5 BRACED RAFTER CONSTRUCTION
477 TABLE R802.5.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
478 TABLE R802.5.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
479 TABLE R802.5.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
480 TABLE R802.5.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
481 TABLE R802.5.2 RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS
482 FIGURE R802.7.1.1 RAFTER NOTCH
483 FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
484 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
485 TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION)
486 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION
487 SECTION R804 COLD-FORMED STEEL ROOF FRAMING
FIGURE R804.1.2 IN-LINE FRAMING
488 TABLE R804.2.3 LOAD-BEARING COLD-FORMED STEEL ROOF FRAMING MEMBER SIZES AND THICKNESSES
FIGURE R804.2.3(1) C-SHAPED SECTION
FIGURE R804.2.3(2) TRACK SECTION
489 FIGURE R804.2.6.1 ROOF FRAMING MEMBER WEB HOLES
490 FIGURE R804.2.6.3 ROOF FRAMING MEMBER WEB HOLE PATCH
491 FIGURE R804.3 COLD-FORMED STEEL ROOF CONSTRUCTION
TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE
492 TABLE R804.3.1.1(1) CEILING JOIST SPANS 10 PSF LIVE LOAD (NO ATTIC STORAGE)
493 TABLE R804.3.1.1(2) CEILING JOIST SPANS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)
TABLE R804.3.1.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
494 FIGURE R804.3.1.1 JOIST TO RAFTER CONNECTION
FIGURE R804.3.1.3(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPED, TRACK OR COLD-ROLLED CHANNEL
495 FIGURE R804.3.1.3(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE R804.3.1.4 SPLICED CEILING JOISTS
496 FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
497 TABLE R804.3.2.1(1) ROOF RAFTER SPANS
TABLE R804.3.2.1(2) ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
498 FIGURE R804.3.2.4 RIDGE MEMBER CONNECTION
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR ROOF RAFTER TO RIDGE MEMBER CONNECTION
499 FIGURE R804.3.5(1) ROOF OR CEILING OPENING
500 FIGURE R804.3.5(2) HEADER TO TRIMMER CONNECTION
TABLE R804.3.7.1 REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEET
501 FIGURE R804.3.7.1(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
FIGURE R804.3.7.1(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
502 FIGURE R804.3.7.2 ROOF BLOCKING DETAIL
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
504 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
SECTION R807 ATTIC ACCESS
506 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 9 – ROOF ASSEMBLIES
508 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 FIRE CLASSIFICATION
509 SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
510 TABLE R905.1.1(1) UNDERLAYMENT TYPES
511 TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
512 TABLE R905.1.1(2)—continued UNDERLAYMENT APPLICATION
TABLE R905.1.1(3) UNDERLAYMENT ATTACHMENT
513 TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES
514 TABLE R905.2.8.2 VALLEY LINING MATERIAL
515 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
516 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE R905.7.5(1) WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
517 TABLE R905.7.5(2) NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
518 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
519 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
520 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
521 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
SECTION R908 REROOFING
522 SECTION R918 SOLAR PHOTOVOLTAIC PANELS/MODULES
524 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 10 – CHIMNEYS AND FIREPLACES
526 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
527 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
528 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
529 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
530 SECTION R1002 MASONRY HEATERS
SECTION R1003 MASONRY CHIMNEYS
532 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
533 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
534 TABLE R1003.20 CRICKET DIMENSIONS
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
SECTION R1004 FACTORY-BUILT FIREPLACES
535 FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1005 FACTORY-BUILT CHIMNEYS
536 SECTION R1006 EXTERIOR AIR SUPPLY
538 PART IV—ENERGY CONSERVATION
540 PART V—MECHANICAL
542 PART VI—FUEL GAS
544 PART VII—PLUMBING
546 PART VIII—ELECTRICAL
548 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 44 – REFERENCED STANDARDS
550 PART IX—REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACCA
ACI
551 AISI
ANSI
APA
552 ASCE/SEI
ASSE
ASTM
561 AWC
AWPA
CEN
562 CPA
CPSC
CSA
CSSB
DASMA
563 DOC
FEMA
FM
GA
HPVA
ICC
564 ISO
NFPA
567 PCA
SBCA
SFM
TMS
568 TPI
UBC
UL
569 ULC
WDMA
WMA
570 APPENDIX A RESERVED
572 APPENDIX B RESERVED
574 APPENDIX C RESERVED
576 APPENDIX D RESERVED
578 APPENDIX E RESERVED
580 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX F – RADON CONTROL METHODS
APPENDIX F RADON CONTROL METHODS
SECTION AF101 SCOPE
SECTION AF102 DEFINITIONS
581 SECTION AF103 REQUIREMENTS
583 FIGURE AF101 EPA MAP OF RADON ZONES
584 TABLE AF101(1) HIGH RADON-POTENTIAL (ZONE 1) COUNTIES
585 TABLE AF101(1)—continued HIGH RADON-POTENTIAL (ZONE 1) COUNTIES
586 FIGURE AF103 RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES
588 APPENDIX G RESERVED
590 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX H – PATIO COVERS
APPENDIX H PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 EXTERIOR WALLS AND OPENINGS
SECTION AH104 HEIGHT
591 SECTION AH105 STRUCTURAL PROVISIONS
SECTION AH106 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
TABLE AH106.4(1) DESIGN WIND PRESSURES FOR SCREEN ENCLOSURE FRAMING
592 TABLE AH106.4(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE
593 FIGURE AH106.4.1 ULTIMATE DESIGN WIND SPEEDS FOR PATIO COVERS AND SCREEN ENCLOSURES
594 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX I – PRIVATE SEWAGE DISPOSAL
APPENDIX I PRIVATE SEWAGE DISPOSAL
SECTION AI101 GENERAL
596 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX J – EXISTING BUILDINGS AND STRUCTURES
APPENDIX J EXISTING BUILDINGS AND STRUCTURES
SECTION AJ101 PURPOSE AND INTENT
SECTION AJ102 COMPLIANCE
597 SECTION AJ103 PRELIMINARY MEETING
SECTION AJ104 EVALUATION OF AN EXISTING BUILDING
598 SECTION AJ105 PERMIT
SECTION AJ201 DEFINITIONS
SECTION AJ301 REPAIRS
599 SECTION AJ401 RENOVATIONS
SECTION AJ501 ALTERATIONS
600 SECTION AJ601 RECONSTRUCTION
SECTION AJ701 REFERENCED STANDARDS
602 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX K – SOUND TRANSMISSION
APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIRBORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
604 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX L – PERMIT FEES
APPENDIX L PERMIT FEES
606 APPENDIX M RESERVED
608 APPENDIX N RESERVED
610 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX O – AUTOMATIC VEHICULAR GATES
APPENDIX O AUTOMATIC VEHICULAR GATES
SECTION AO101 GENERAL
SECTION AO102 DEFINITION
SECTION AO103 AUTOMATIC VEHICULAR GATES
SECTION AO104 REFERENCED STANDARDS
612 APPENDIX P RESERVED
614 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX Q – TINY HOUSES
APPENDIX Q TINY HOUSES
SECTION AQ101 GENERAL
SECTION AQ102 DEFINITIONS
SECTION AQ103 CEILING HEIGHT
SECTION AQ104 LOFTS
615 SECTION AQ105 EMERGENCY ESCAPE AND RESCUE OPENINGS
616 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX R – LIGHT STRAW-CLAY CONSTRUCTION
APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
SECTION AR102 DEFINITIONS
SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
617 TABLE AR103.2.3 REQUIREMENTS AND PROPERTIES OF LIGHT STRAW-CLAY MIXTURES
FIGURE AR103.2.4(1) LIGHT STRAW-CLAY WALL WITH LARSEN TRUSSES
FIGURE AR103.2.4(2) LIGHT STRAW-CLAY WALL SINGLE STUD WIDTH
618 FIGURE AR103.2.4(3) LIGHT STRAW-CLAY WALL WITH BLIND STUDS
619 SECTION AR104 THERMAL PERFORMANCE
620 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX S – STRAWBALE CONSTRUCTION
APPENDIX S STRAWBALE CONSTRUCTION
SECTION AS101 GENERAL
SECTION AS102 DEFINITIONS
621 FIGURE AS102.1 TYPICAL STRAWBALE WALL SYSTEMS
FIGURE AS102.1 BALE ORIENTAITIONS
622 SECTION AS103 BALES
FIGURE AS103.2 APPROXIMATE DIMENSIONS OF COMMON STRAW BALES
623 SECTION AS104 FINISHES
624 FIGURE AS105.1(1) TYPICAL BASE OF PLASTERED STRAWBALE WALL ON CONCRETE SLAB AND FOOTING
625 FIGURE AS105.1(2) TYPICAL BASE OF PLASTERED STRAWBALE WALL OVER RAISED FLOOR
626 FIGURE AS105.1(3) TYPICAL TOP OF LOAD-BEARING STRAWBALE WALL
FIGURE AS105.1(4) TYPICAL TOP OF POST-AND-BEAM WALL WITH PLASTERED STRAWBALE INFILL
627 SECTION AS105 STRAWBALE WALLS—GENERAL
TABLE AS105.4 OUT-OF-PLANE RESISTANCE METHODS AND UNRESTRAINED WALL DIMENSION LIMITS
629 SECTION AS106 STRAWBALE WALLS—STRUCTURAL
TABLE AS106.6.1 MINIMUM COMPRESSIVE STRENGTH FOR PLASTERS ON STRUCTURAL WALLS
630 TABLE AS106.12 ALLOWABLE SUPERIMPOSED VERTICAL LOADS (LBS/FOOT) FOR PLASTERED LOAD-BEARING STRAWBALE WALLS
631 EQUATION AS-1
TABLE AS106.13(1) PLASTERED STRAWBALE BRACED WALL PANEL TYPES
632 TABLE AS106.13(2) BRACING REQUIREMENTS FOR STRAWBALE-BRACED WALL PANELS BASED ON WIND SPEED
633 TABLE AS106.13(3) BRACING REQUIREMENTS FOR STRAWBALE-BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY
634 SECTION AS107 FIRE RESISTANCE
SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
636 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX T – SOLAR-READY PROVISIONS—DETACHED ONE- ANDTWO-FAMILY DWELLINGS AND TOWNHOUSES
APPENDIX T [RE] SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION T101 SCOPE
SECTION T102 (RA102) GENERAL DEFINITION
SECTION T103 (RA103) SOLAR-READY ZONE
638 APPENDIX U RESERVED
640 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX V – SWIMMING POOL SAFETY ACT
APPENDIX V SWIMMING POOL SAFETY ACT
AV100 PRIVATE SWIMMING POOLS (STATEWIDE)
AV100.1 DEFINITIONS
AV100.2 CONSTRUCTION PERMIT; SAFETY FEATURES REQUIRED
641 AV100.3 ENCLOSURE; REQUIRED CHARACTERISTICS
AV100.4 AGREEMENTS TO BUILD; NOTICE OF PROVISIONS
AV100.5 EXEMPT FACILITIES
AV100.6 APPLICATION TO FACILITIES REGULATED BY DEPARTMENT OF SOCIAL SERVICES
AV100.7 MODIFICATION AND INTERPRETATION OF DIVISION
642 AV100.8 CONSTRUCTION REQUIREMENTS FOR BUILDING A POOL OR SPA
AV100.9 INFORMATIVE DOCUMENTS
644 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX W – AREAS PROTECTED BY THE FACILITIESOF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
APPENDIX W AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
AW101 GENERAL
AW102 DEFINITIONS
645 AW103 STRUCTURAL STABILITY
AW104 EVACUATION LOCATIONS
AW105 SPACE WITHIN THE BUILDING
646 AW106 DECKS AND BALCONIES THAT ARE EVACUATION LOCATIONS
AW107 ROOFTOP EVACUATION LOCATIONS
AW108 ATTICS THAT ARE EVACUATION LOCATIONS
AW109 ALTERNATE MEANS OF PROTECTION
647 FIGURE K103.1
648 FIGURE K103.1
650 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX X – EMERGENCY HOUSING
APPENDIX X EMERGENCY HOUSING
SECTION AX101 GENERAL
SECTION AX102 DEFINITIONS
651 SECTION AX103 EMERGENCY HOUSING
SECTION AX104 EMERGENCY SLEEPING CABINS
652 SECTION AX105 EMERGENCY TRANSPORTABLE HOUSING UNITS
SECTION AX106 TENTS AND MEMBRANE STRUCTURES
SECTION AX107 ACCESSIBILITY
653 SECTION AX108 LOFTS IN EMERGENCY HOUSING
SECTION AX109 LOCATION, MAINTENANCE AND IDENTIFICATION
654 SECTION AX110 EMERGENCY HOUSING FACILITIES
656 INDEX
666 HISTORY NOTE APPENDIX
668 HELPFUL TOOLS FOR YOUR CALIFORNIA RESIDENTIAL CODE
669 ICC ASSESSMENT CENTER