Shopping Cart

No products in the cart.

CA Residential Code Title 24 Part 2.5 2022 1stptg

$86.13

California Residential Code, Title 24, Part 2.5 (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2022
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

California Residential Code (CRC) contains building provisions that cover construction of one- and two-family dwellings and townhouses that are three stories or less. This is a fully integrated code based on the 2021 International Residential Code® (Chapters 2-10). California amendments provide consistency with model code format, state and federal laws and regulations, and unique California conditions with regard to the construction of one- and two- family dwellings and townhouses. This code does not include Energy, Mechanical, Plumbing, or Electrical standards, which are found in other parts of Title 24. Effective Date: January 1, 2023.

PDF Catalog

PDF Pages PDF Title
1 2022 CALIFORNIA RESIDENTIAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2.5
2 2022 CALIFORNIA RESIDENTIAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2.5 TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGMENTS
6 CALIFORNIA CODE OF REGULATIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
7 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
8 CALIFORNIA MATRIX ADOPTION TABLES
12 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
14 ARRANGEMENT AND FORMAT OF THE 2021 IRC
24 TABLE OF CONTENTS
30 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND APPLICATION
31 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND APPLICATION—continued
32 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND APPLICATION
DIVISION 1 CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
34 SECTION 1.2 RESERVED
SECTION 1.3 RESERVED
SECTION 1.4 RESERVED
SECTION 1.5 RESERVED
SECTION 1.6 RESERVED
SECTION 1.7 RESERVED
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT (HCD)
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
36 SECTION 1.8.3 LOCAL ENFORCING AGENCY
SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
37 SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
38 SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
SECTION 1.8.8 APPEALS BOARD
39 SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
40 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 RESERVED
SECTION 1.10 RESERVED
SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
44 SECTION 1.12 RESERVED
SECTION 1.13 RESERVED
SECTION 1.14 RESERVED
46 DIVISION II ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
SECTION R102 APPLICABILITY
47 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 DEPARTMENT OF BUILDING SAFETY
SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
48 SECTION R105 PERMITS
51 SECTION R106 CONSTRUCTION DOCUMENTS
52 SECTION R107 TEMPORARY STRUCTURES AND USES
SECTION R108 FEES
SECTION R109 INSPECTIONS
53 SECTION R110 CERTIFICATE OF OCCUPANCY
54 SECTION R111 SERVICE UTILITIES
SECTION R112 BOARD OF APPEALS
SECTION R113 VIOLATIONS
55 SECTION R114 STOP WORK ORDER
56 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
57 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
58 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
59 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
60 PART II—DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
74 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING
75 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING—continued
76 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING—continued
78 PART III—BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 SITE DRAINAGE
SECTION R301 DESIGN CRITERIA
81 TABLE R301.2 CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
82 FIGURE R301.2(1) WEATHERING PROBABILITY MAP FOR CONCRETE
83 FIGURE R301.2(2) ULTIMATE DESIGN WIND SPEEDS
84 FIGURE R301.2(3) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES
85 FIGURE R301.2(4) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES
86 FIGURE R301.2.1 COMPONENT AND CLADDING PRESSURE ZONES
87 TABLE R301.2.1(1) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B
88 TABLE R301.2.1(1)—continued COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B
89 TABLE R301.2.1(1)—continued COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B
90 TABLE R301.2.1(2) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR Table R301.2.1(1)
91 FIGURE R301.2.1.1 REGIONS WHERE WIND DESIGN IS REQUIRED
92 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELS
TABLE R301.2.1.3 WIND SPEED CONVERSIONSa
TABLE R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
93 FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION
95 FIGURE R301.2.2.1(1) SEISMIC DESIGN CATEGORIES—ALASKAa
96 FIGURE R301.2.2.1(2) SEISMIC DESIGN CATEGORIES—HAWAIIa
97 FIGURE R301.2.2.1(3) SEISMIC DESIGN CATEGORIES—PUERTO RICOa
98 FIGURE R301.2.2.1(4) SEISMIC DESIGN CATEGORIES—NORTHERN MARIANA ISLANDS AND AMERICAN SAMOAa
99 FIGURE R301.2.2.1(5) SEISMIC DESIGN CATEGORIES—UNITED STATESa
100 FIGURE R301.2.2.1(6) SEISMIC DESIGN CATEGORIES—UNITED STATESa
101 FIGURE R301.2.2.1.1(1) ALTERNATE SEISMIC DESIGN CATEGORIES—ALASKAa
102 FIGURE R301.2.2.1.1(2) ALTERNATE SEISMIC DESIGN CATEGORIES—HAWAIIa
103 FIGURE R301.2.2.1.1(3) ALTERNATE SEISMIC DESIGN CATEGORIES—PUERTO RICOa
104 FIGURE R301.2.2.1.1(4) ALTERNATE SEISMIC DESIGN CATEGORIES—NORTHERN MARIANA ISLANDS AND AMERICAN SAMOAa
105 FIGURE R301.2.2.1.1(5) ALTERNATE SEISMIC DESIGN CATEGORIES—UNITED STATESa
106 FIGURE R301.2.2.1.1(6) ALTERNATE SEISMIC DESIGN CATEGORIES—UNITED STATESa
107 TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
109 SECTION R302 FIRE-RESISTANT CONSTRUCTION
110 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
111 TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSb
TABLE R302.1(1) EXTERIOR WALLS
112 TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS AND ACCESSORY BUILDINGS WITH AUTOMATIC RESIDENTIAL FIRE SPRINKLER PROTECTION
115 TABLE R302.6 DWELLING-GARAGE AND/OR CARPORT SEPARATION
117 SECTION R303 LIGHT, VENTILATION AND HEATING
119 SECTION R304 MINIMUM ROOM AREAS
SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
120 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
122 FIGURE R308.4.7 HAZARDOUS GLAZING LOCATIONS AT BOTTOM STAIR LANDINGS
123 SECTION R309 GARAGES AND CARPORTS
SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
125 SECTION R311 MEANS OF EGRESS
129 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
130 TABLE R313.3.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
132 FIGURE R313.3.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
134 EQUATION 29-1
135 TABLE R313.3.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
136 TABLE R313.3.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
TABLE R313.3.6.2(3) ELEVATION LOSS (PLe)
137 TABLE R313.3.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
138 TABLE R313.3.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
139 TABLE R313.3.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
140 TABLE R313.3.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
141 TABLE R313.3.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
142 TABLE R313.3.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
143 SECTION R314 SMOKE ALARMS
147 SECTION R315 CARBON MONOXIDE ALARMS
149 SECTION R316 FOAM PLASTIC
151 SECTION R317 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS AGAINST DECAY
152 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
153 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY
SECTION R321 ELEVATORS AND PLATFORM LIFTS
154 FIGURE R318.4 TERMITE INFESTATION PROBABILITY MAP
155 SECTION R322 FLOOD-RESISTANT CONSTRUCTION
158 SECTION R323 STORM SHELTERS
159 SECTION R324 SOLAR ENERGY SYSTEMS
160 SECTION R325 MEZZANINES
161 SECTION R326 HABITABLE ATTICS
SECTION R327 AGING-IN-PLACE DESIGN AND FALL PREVENTION
162 SECTION R328 ENERGY STORAGE SYSTEMS
164 FIGURE R328.8.1 ESS VEHICLE IMPACT PROTECTION
165 SECTION R329 STATIONARY ENGINE GENERATORS
SECTION R330 STATIONARY FUEL CELL POWER SYSTEMS
SECTION R334 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING
SECTION R335 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-3.1
168 SECTION R336 LARGE FAMILY DAY-CARE HOMES
169 SECTION R337 MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION R337.1 SCOPE, PURPOSE AND APPLICATION
170 SECTION R337.2 DEFINITIONS
171 SECTION R337.3 STANDARDS OF QUALITY
172 SECTION R337.4 IGNITION-RESISTANT CONSTRUCTION
173 SECTION R337.5 ROOFING
SECTION R337.6 VENTS
SECTION R337.7 EXTERIOR COVERING
176 SECTION R337.8 EXTERIOR WINDOWS, SKYLIGHTS AND DOORS
177 SECTION R337.9 DECKING
178 SECTION R337.10 ACCESSORY BUILDINGS AND MISCELLANEOUS STRUCTURES
179 SECTION R338 ELECTRIC VEHICLE
SECTION R340 POLLUTANT CONTROL
180 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 4 – FOUNDATIONS
182 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
183 SECTION R402 MATERIALS
184 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
185 TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
186 TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER OR LATH AND PLASTER
187 TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE CONCRETE OR PARTIALLY GROUTED MASONRY WALL CONSTRUCTION
188 FIGURE R403.1(1) PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SEISMIC DESIGN CATEGORIES A, B AND C
189 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
190 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEM WALLS IN SDC D0, D1 AND D2
193 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
194 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
195 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
196 TABLE R403.3(2) AIR-FREEZING INDEX FOR US LOCATIONS BY COUNTY
197 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR US LOCATIONS BY COUNTY
198 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR US LOCATIONS BY COUNTY
199 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR US LOCATIONS BY COUNTY
200 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR US LOCATIONS BY COUNTY
201 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
202 SECTION R404 FOUNDATION AND RETAINING WALLS
203 TABLE R403.4 MINIMUM DEPTH (D) AND WIDTH (W) OF CRUSHED STONE FOOTINGS
204 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
205 TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLSf
206 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 5 INCHES
207 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 6.75 INCHES
208 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d ≥ 8.75 INCHES
209 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
210 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS
211 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
212 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS
213 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS
214 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS
215 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10- AND 12-INCH NOMINAL FLAT BASEMENT WALLS
216 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND ALTERNATE GRADE OF STEEL
221 FIGURE R404.1.5.3 FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
223 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION
SECTION R405 FOUNDATION DRAINAGE
224 SECTION R406 FOUNDATION WATER PROOFING AND DAMPPROOFING
225 TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
SECTION R407 COLUMNS
226 SECTION R408 UNDER-FLOOR SPACE
228 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 5 – FLOORS
230 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
231 FIGURE R502.2 FLOOR CONSTRUCTION
232 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
233 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
234 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
235 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
236 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY
237 TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY
238 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
239 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
240 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT
241 TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
SECTION R504 PRESSURE PRESERVATIVE-TREATED WOOD FLOORS (ON GROUND)
SECTION R505 COLD-FORMED STEEL FLOOR FRAMING
243 TABLE R505.3.1(1) FLOOR-TO-FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
244 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(1) FLOOR-TO-EXTERIOR LOAD-BEARING WALL STUD CONNECTION
245 FIGURE R505.3.1(2) FLOOR-TO-WOOD-SILL CONNECTION
FIGURE R505.3.1(3) FLOOR-TO-FOUNDATION CONNECTION
246 FIGURE R505.3.1(4) CANTILEVERED FLOOR-TO-FOUNDATION CONNECTION
FIGURE R505.3.1(5) CANTILEVERED FLOOR-TO-WOOD-SILL CONNECTION
247 FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
248 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
249 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE OR CONTINUOUS SPANS
250 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
251 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
FIGURE R505.3.4(2) BEARING STIFFENER
252 FIGURE R505.3.7 TRACK SPLICE
FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING
253 FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
254 FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
SECTION R506 CONCRETE FLOORS (ON GROUND)
255 SECTION R507 EXTERIOR DECKS
256 TABLE R507.2.3 FASTENER AND CONNECTOR SPECIFICATIONS FOR DECKS
FIGURE R507.3 DECK POSTS TO DECK FOOTING CONNECTION
257 TABLE R507.3.1 MINIMUM FOOTING SIZE FOR DECKS
258 TABLE R507.4 DECK POST HEIGHT
259 TABLE R507.4—continued DECK POST HEIGHT
260 FIGURE R507.5 TYPICAL DECK JOIST SPANS
261 TABLE R507.5(1) MAXIMUM DECK BEAM SPAN—40 PSF LIVE LOADc
262 TABLE R507.5(2) MAXIMUM DECK BEAM SPAN—50 PSF GROUND SNOW LOADc
263 TABLE R507.5(3) MAXIMUM DECK BEAM SPAN—60 PSF GROUND SNOW LOADc
264 TABLE R507.5(4) MAXIMUM DECK BEAM SPAN—70 PSF GROUND SNOW LOADc
265 TABLE R507.5(5) JOIST SPAN FACTORS FOR CALCULATING EFFECTIVE DECK JOIST SPAN
FIGURE R507.5.1(1) DECK BEAM TO DECK POST
266 FIGURE R507.5.1(2) NOTCHED POST-TO-BEAM CONNECTION
267 FIGURE R507.6 TYPICAL DECK JOIST SPANS
268 TABLE R507.6 MAXIMUM DECK JOIST SPANS
269 TABLE R507.6—continued MAXIMUM DECK JOIST SPANS
TABLE R507.7 MAXIMUM JOIST SPACING FOR WOOD DECKING
270 TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOIST
271 TABLE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
FIGURE R507.9.1.3(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
FIGURE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
272 FIGURE R507.9.2(1) DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R507.9.2(2) DECK ATTACHMENT FOR LATERAL LOADS
274 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 6 – WALL CONSTRUCTION
276 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
278 TABLE R602.3(1) FASTENING SCHEDULE
279 TABLE R602.3(1)—continued FASTENING SCHEDULE
280 TABLE R602.3(1)—continued FASTENING SCHEDULE
281 TABLE R602.3(1)—continued FASTENING SCHEDULE
282 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
283 TABLE R602.3(2)—continued ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHINGa
284 TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
TABLE R602.3(6) ALTERNATE WOOD BEARING WALL STUD SIZE, HEIGHT AND SPACING
285 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
286 FIGURE R602.3(2) FRAMING DETAILS
287 TABLE R602.3.2 SINGLE TOP-PLATE SPLICE CONNECTION DETAILS
288 FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
289 TABLE R602.7.5 MINIMUM NUMBER OF FULL-HEIGHT STUDS AT EACH END OF HEADERS IN EXTERIOR WALLSa
FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
290 TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS
291 TABLE R602.7(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS
292 TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS
TABLE R602.7(3) GIRDER AND HEADER SPANSa FOR OP
293 FIGURE R602.7.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
FIGURE R602.7.2 RIM BOARD HEADER CONSTRUCTION
294 TABLE R602.7.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
295 FIGURE R602.10.1.1 BRACED WALL LINES
296 TABLE R602.10.1.3 BRACED WALL LINE SPACING
FIGURE R602.10.1.4 ANGLED WALLS
298 FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
299 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
300 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
301 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
302 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
303 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
304 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
305 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
306 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
308 TABLE R602.10.4 BRACING METHODS
309 TABLE R602.10.4—continued BRACING METHODS
311 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
312 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
313 FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
314 FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
315 TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELSa
316 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
317 FIGURE R602.10.6.5.2 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
318 TABLE R602.10.6.5.4 METHOD BV-WSP WALL BRACING REQUIREMENTSd
319 TABLE R602.10.6.5.4—continued METHOD BV-WSP WALL BRACING REQUIREMENTSd
320 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
321 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
322 FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
323 FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
324 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
326 FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
327 FIGURE R602.12.5BRACING UNIT DISTRIBUTION
328 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
329 SECTION R603 COLD-FORMED STEEL WALL FRAMING
330 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTSa, b
331 FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
332 FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
FIGURE R603.3.1(4) WIND UPLIFT CONNECTOR
333 TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS
334 TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
335 TABLE R603.3.2(3) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
336 TABLE R603.3.2(4) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
337 TABLE R603.3.2(5) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
338 TABLE R603.3.2(6) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
339 TABLE R603.3.2(7) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
340 TABLE R603.3.2(8) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
341 TABLE R603.3.2(9) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
342 TABLE R603.3.2(10) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
343 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
344 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
345 TABLE R603.3.2(13) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
346 TABLE R603.3.2(14) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
347 TABLE R603.3.2(15) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
348 TABLE R603.3.2(16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
349 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHT
350 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT
351 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
352 FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
FIGURE R603.3.5 TRACK SPLICE
353 FIGURE R603.4 CORNER FRAMING
354 TABLE R603.6(1) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
355 TABLE R603.6(2) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
356 TABLE R603.6(3) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
357 TABLE R603.6(4) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
358 TABLE R603.6(5) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
359 TABLE R603.6(6) BOX-BEAM AND BACK-TO-BACK HEADER SPANS
360 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
361 FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
362 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTS
TABLE R603.8 HEAD AND SILL TRACK SPAN
363 FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS
364 TABLE R603.9.2(2) FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
FIGURE R603.9.4.2 CORNER STUD HOLD-DOWN DETAIL
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
365 TABLE R603.9.5(1) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
366 TABLE R603.9.5(2) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
367 TABLE R603.9.5(3) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
368 TABLE R603.9.5(4) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
SECTION R606 GENERAL MASONRY CONSTRUCTION
369 TABLE R606.2.8 MORTAR PROPORTIONS
370 TABLE R606.2.12 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
371 TABLE R606.3.4.1 MINIMUM CORROSION PROTECTION
TABLE R606.3.5.1 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
373 TABLE R606.6.4 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
374 TABLE R606.9 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
375 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
376 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
377 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D2
TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
379 TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
380 SECTION R607 GLASS UNIT MASONRY
381 FIGURE R607.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
382 SECTION R608 EXTERIOR CONCRETE WALL CONSTRUCTION
383 TABLE R608.3 DIMENSIONAL REQUIREMENTS FOR WALLSa
384 FIGURE R608.3(1) FLAT WALL SYSTEM
FIGURE R608.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R608.3(3) SCREEN-GRID WALL SYSTEM
385 TABLE R608.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
386 FIGURE R608.5.4(1) LAP SPLICES
FIGURE R608.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION
387 FIGURE R608.5.4(3) STANDARD HOOKS
388 TABLE R608.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND ALTERNATIVE GRADE OF STEEL
389 FIGURE R608.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R608.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST STORY AND LIGHT-FRAME SECOND STORY
390 FIGURE R608.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
391 TABLE R608.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS
392 TABLE R608.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS
393 TABLE R608.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS
394 TABLE R608.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS
395 TABLE R608.6(4)—continued MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS
396 EQUATION R6-1
EQUATION R6-2
397 TABLE R608.7.1.1(1) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY
398 TABLE R608.7.1.1(1)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORYa, c, d, e, f, g
399 TABLE R608.7.1.1(2) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY
400 TABLE R608.7.1.1(2)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORYa, c, d, e, f, g
401 TABLE R608.7.1.1(3) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
402 TABLE R608.7.1.1(3)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGEa, c, d, e, f, g
403 TABLE R608.7.1.1(4) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
404 TABLE R608.7.1.1(5) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEET
405 TABLE R608.7.1.1(6) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLS
406 FIGURE R608.7.1.1(1) MINIMUM SOLID WALL LENGTH
407 FIGURE R608.7.1.1(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
408 FIGURE R608.7.1.1(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
410 FIGURE R608.8(1) REINFORCEMENT OF OPENINGS
FIGURE R608.8(2) LINTEL FOR FLAT WALLS
411 FIGURE R608.8(3) LINTELS FOR WAFFLE-GRID WALLS
412 FIGURE R608.8(4) LINTELS FOR SCREEN-GRID WALLS
413 TABLE R608.8(1) LINTEL DESIGN LOADING CONDITIONS
414 TABLE R608.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
415 TABLE R608.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
416 TABLE R608.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
417 TABLE R608.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
418 TABLE R608.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
419 TABLE R608.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
420 TABLE R608.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
421 TABLE R608.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
422 TABLE R608.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
423 TABLE R608.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
424 TABLE R608.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
425 TABLE R608.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
426 TABLE R608.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
427 TABLE R608.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
428 TABLE R608.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLSa, b, c, d, e, g
TABLE R608.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
430 FIGURE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
431 TABLE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
432 FIGURE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
433 TABLE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
434 FIGURE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
435 TABLE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
436 FIGURE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
437 TABLE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
438 FIGURE R608.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
439 TABLE R608.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
440 FIGURE R608.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
441 TABLE R608.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
442 FIGURE R608.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
443 TABLE R608.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
444 FIGURE R608.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
445 TABLE R608.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
446 FIGURE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
447 TABLE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
448 FIGURE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
449 TABLE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
450 FIGURE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
451 TABLE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
452 FIGURE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
453 TABLE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
SECTION R609 EXTERIOR WINDOWS AND DOORS
455 FIGURE R609.7.2(1) THROUGH THE FRAME
FIGURE R609.7.2(2) FRAME CLIP
FIGURE R609.7.2(3) THROUGH THE FRAME
FIGURE R609.7.2(4) FRAME CLIP
456 FIGURE R609.7.2(5) THROUGH THE FLANGE
FIGURE R609.7.2(6) THROUGH THE FLANGE
FIGURE R609.7.2(7) FRAME CLIP
FIGURE R609.7.2(8) THROUGH THE FLANGE
457 SECTION R610 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
FIGURE R610.4 SIP WALL PANEL
459 TABLE R610.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY
460 TABLE R610.5(2) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF ONLY
461 FIGURE R610.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R610.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
462 FIGURE R610.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R610.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
463 FIGURE R610.5(5) SIP WALL-TO-WALL HANGING FLOOR FRAME CONNECTION
FIGURE R610.5.1 SIP WALL FRAMING CONFIGURATION
464 FIGURE R610.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R610.5.4 SIP CORNER FRAMING DETAIL
465 FIGURE R610.8 TYPICAL SIP WALL PANEL-TO-PANEL CONNECTION DETAILS
466 TABLE R610.8 MAXIMUM SPANS FOR 117/8-INCH OR DEEPER SIP HEADERS
468 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 7 – WALL COVERING
470 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
471 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONS
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
473 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
474 TABLE R702.3.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE R702.4.2 BACKER BOARD MATERIALS
475 TABLE R702.7(1) VAPOR RETARDER MATERIALS AND CLASSES
TABLE R702.7(2) VAPOR RETARDER OPTIONS
SECTION R703 EXTERIOR COVERING
476 TABLE R702.7(3) CLASS III VAPOR RETARDERS
TABLE R702.7(4) CONTINUOUS INSULATION WITH CLASS II VAPOR RETARDER
477 TABLE R702.7(5) IECC VS. CALIFORNIA ENERGY CODE CLIMATE ZONE COMPARISON
478 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
479 TABLE R703.3(1)—continued SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
480 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTION
TABLE R703.3.2 LIMITS FOR ATTACHMENT PER Table R703.3(1)
TABLE R703.3.3 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
481 TABLE R703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLSa
482 TABLE R703.6.3(1) SINGLE-COURSE SIDEWALL FASTENERS
TABLE R703.6.3(2) DOUBLE-COURSE SIDEWALL FASTENERS
484 FIGURE R703.8(1) TYPICAL MASONRY VENEER WALL DETAILSd
485 FIGURE R703.8(2) TYPICAL MASONRY VENEER WALL DETAILSe
486 TABLE R703.8(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.8(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
487 FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
488 TABLE R703.8.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER
TABLE R703.8.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
489 FIGURE R703.8.3.2 MASONRY VENEER OPENING
TABLE R703.8.4(1) TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
490 TABLE R703.8.4(2) REQUIRED BRICK TIE SPACING FOR DIRECT APPLICATION TO WOOD STRUCTURAL PANEL SHEATHING
492 TABLE R703.11.2 REQUIRED MINIMUM WIND LOAD DESIGN PRESSURE RATING FOR VINYL SIDING INSTALLED OVER FOAM PLASTIC SHEATHING ALONE
493 TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
494 TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
495 TABLE R703.16.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
TABLE R703.16.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
496 SECTION R704 SOFFITS
497 FIGURE R704.2.1(1) TYPICAL SINGLE-SPAN VINYL SOFFIT PANEL SUPPORT
498 FIGURE R704.2.1(2) TYPICAL DOUBLE-SPAN VINYL SOFFIT PANEL SUPPORT
499 TABLE R704.3.4 PRESCRIPTIVE ALTERNATIVE FOR WOOD STRUCTURAL PANEL SOFFIT
500 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 8 – ROOF-CEILING CONSTRUCTION
502 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
504 TABLE R802.4.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
505 TABLE R802.4.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
506 TABLE R802.4.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)(Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
507 TABLE R802.4.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
508 TABLE R802.4.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
509 TABLE R802.4.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
510 TABLE R802.4.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
511 TABLE R802.4.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
512 TABLE R802.4.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
513 TABLE R802.4.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
514 TABLE R802.4.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
515 TABLE R802.4.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
516 TABLE R802.4.1(7) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
517 TABLE R802.4.1(7)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
518 TABLE R802.4.1(8) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
519 TABLE R802.4.1(8)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
520 TABLE R802.4.1(9) RAFTER SPAN ADJUSTMENT FACTOR
FIGURE R802.4.5 BRACED RAFTER CONSTRUCTION
521 TABLE R802.5.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
522 TABLE R802.5.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
523 TABLE R802.5.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
524 TABLE R802.5.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
525 TABLE R802.5.2(1) RAFTER/CEILING JOIST HEEL JOINT CONNECTIONSg
TABLE R802.5.2(2) HEEL JOINT CONNECTION ADJUSTMENT FACTORS
526 FIGURE R802.7.1.1 RAFTER NOTCH
527 FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
529 TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION
530 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION)
531 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
SECTION R804 COLD-FORMED STEEL ROOF FRAMING
532 FIGURE R804.3 COLD-FORMED STEEL ROOF CONSTRUCTION
533 TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE
534 TABLE R804.3.1.1(1) CEILING JOIST SPANS 10 PSF LIVE LOAD (NO ATTIC STORAGE)
535 TABLE R804.3.1.1(2) CEILING JOIST SPANS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)
536 TABLE R804.3.1.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
FIGURE R804.3.1.1 JOIST TO RAFTER CONNECTION
537 FIGURE R804.3.1.3(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPED, TRACK OR COLD-ROLLED CHANNEL
FIGURE R804.3.1.3(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
538 FIGURE R804.3.1.4 SPLICED CEILING JOISTS
539 TABLE R804.3.2.1(1) ROOF RAFTER SPANS
TABLE R804.3.2.1(2) ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
540 FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
541 FIGURE R804.3.2.4 RIDGE MEMBER CONNECTION
542 TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR ROOF RAFTER TO RIDGE MEMBER CONNECTIONa
543 FIGURE R804.3.5(1) ROOF OR CEILING OPENING
FIGURE R804.3.5(2) HEADER TO TRIMMER CONNECTION
544 TABLE R804.3.7.1 REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEET
545 FIGURE R804.3.7.1(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
FIGURE R804.3.7.1(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
546 FIGURE R804.3.7.2 ROOF BLOCKING DETAIL
547 SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
548 SECTION R807 ATTIC ACCESS
549 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
550 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 9 – ROOF ASSEMBLIES
552 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 FIRE CLASSIFICATION
553 SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
554 TABLE R905.1.1(1) UNDERLAYMENT TYPES
555 TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
556 TABLE R905.1.1(3) UNDERLAYMENT APPLICATION
TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES
557 TABLE R905.2.8.2 VALLEY LINING MATERIAL
558 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
559 TABLE R905.4.4.1 CLASSIFICATION OF STEEP SLOPE METAL ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161
560 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
561 TABLE R905.7.5(1) WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.7.5(2) NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
562 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
563 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
564 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
565 TABLE R905.16.6 CLASSIFICATION OF PHOTOVOLTAIC SHINGLES
SECTION R906 ROOF INSULATION
566 TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
SECTION R908 REROOFING
568 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 10 – CHIMNEYS AND FIREPLACES
570 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
571 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
572 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
574 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
SECTION R1002 MASONRY HEATERS
575 SECTION R1003 MASONRY CHIMNEYS
577 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
578 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
579 TABLE R1003.20 CRICKET DIMENSIONS
FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1004 FACTORY-BUILT FIREPLACES
SECTION R1005 FACTORY-BUILT CHIMNEYS
580 SECTION R1006 EXTERIOR AIR SUPPLY
582 PART IV—ENERGY CONSERVATION
584 PART V—MECHANICAL
586 PART VI—FUEL GAS
588 PART VII—PLUMBING
590 PART VIII—ELECTRICAL
592 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 44 – REFERENCED STANDARDS
594 PART IX—REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACCA
ACI
595 AISI
AMCA
ANCE
ANSI
596 APA
ASCE/SEI
ASME
597 ASTM
606 AWC
AWPA
CEN
607 CPA
CPSC
CSA
CSSB
DASMA
608 DHA
DOC
FEMA
FM
GA
ICC
609 ISO
NFPA
611 PCA
SBCA
612 SFM
TMS
TPI
UBC
UL
614 ULC
WDMA
WMA
616 APPENDIX AA RESERVED
618 APPENDIX AB RESERVED
620 APPENDIX AC RESERVED
622 APPENDIX AD RESERVED
624 APPENDIX AE RESERVED
626 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AF – RADON CONTROL METHODS
APPENDIX AF RADON CONTROL METHODS
SECTION AF101 SCOPE
SECTION AF102 DEFINITIONS
627 FIGURE AF101.1 EPA MAP OF RADON ZONES
628 TABLE AF101.1
629 TABLE AF101.1—continued
630 TABLE AF101.1—continued
631 TABLE AF101.1—continued
632 TABLE AF101.1—continued
633 FIGURE AF103.1 RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES
634 SECTION AF103 REQUIREMENTS
635 SECTION AF104 TESTING
638 APPENDIX AG RESERVED
640 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AH – PATIO COVERS
APPENDIX AH PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 EXTERIOR WALLS AND OPENINGS
641 SECTION AH104 HEIGHT
SECTION AH105 STRUCTURAL PROVISIONS
SECTION AH106 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
TABLE AH106.4.1(1) DESIGN WIND PRESSURES FOR SCREEN ENCLOSURE FRAMING
642 TABLE AH106.4.1(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE
643 FIGURE AH106.4.1 ULTIMATE DESIGN WIND SPEEDS FOR PATIO COVERS AND SCREEN ENCLOSURES
644 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AI – PRIVATE SEWAGE DISPOSAL
APPENDIX AI PRIVATE SEWAGE DISPOSAL
SECTION AI101 GENERAL
646 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AJ – EXISTING BUILDINGS AND STRUCTURES
APPENDIX AJ EXISTING BUILDINGS AND STRUCTURES
SECTION AJ101 PURPOSE AND INTENT
SECTION AJ102 COMPLIANCE
647 SECTION AJ103 PRELIMINARY MEETING
648 SECTION AJ104 EVALUATION OF AN EXISTING BUILDING
SECTION AJ105 PERMIT
SECTION AJ106 DEFINITIONS
SECTION AJ107 REPAIRS
649 SECTION AJ108 RENOVATIONS
SECTION AJ109 ALTERATIONS
650 SECTION AJ110 RECONSTRUCTION
SECTION AJ111 REFERENCED STANDARDS
TABLE AJ111.1 REFERENCED STANDARDS
652 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AK – SOUND TRANSMISSION
APPENDIX AK SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIRBORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
653 TABLE AK104.1 REFERENCED STANDARDS
654 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AL – PERMIT FEES
APPENDIX AL PERMIT FEES
SECTION AL101 GENERAL
TABLE AL101.1 PERMIT FEE SCHEDULE
656 APPENDIX AM RESERVED
658 APPENDIX AN RESERVED
660 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AO – AUTOMATIC VEHICULAR GATES
APPENDIX AO AUTOMATIC VEHICULAR GATES
SECTION AO101 GENERAL
SECTION AO102 DEFINITION
SECTION AO103 AUTOMATIC VEHICULAR GATES
SECTION AO104 REFERENCED STANDARDS
TABLE AO104.1 REFERENCED STANDARDS
662 APPENDIX AP RESERVED
664 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AQ – TINY HOUSES
APPENDIX AQ TINY HOUSES
SECTION AQ101 GENERAL
SECTION AQ102 DEFINITIONS
SECTION AQ103 CEILING HEIGHT
SECTION AQ104 LOFTS
665 FIGURE AQ104.1.3 HEIGHT EFFECT ON LOFT AREA
666 SECTION AQ105 EMERGENCY ESCAPE AND RESCUE OPENINGS
SECTION AQ106 ENERGY CONSERVATION
668 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AR – LIGHT STRAW-CLAY CONSTRUCTION
APPENDIX AR LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
SECTION AR102 DEFINITIONS
SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
669 TABLE AR103.2.3 REQUIREMENTS AND PROPERTIES OF LIGHT STRAW-CLAY MIXTURESa
670 FIGURE AR103.2.4(1) LIGHT STRAW-CLAY WALL WITH LARSEN TRUSSES
FIGURE AR103.2.4(2) LIGHT STRAW-CLAY WALL SINGLE STUD WIDTH
FIGURE AR103.2.4(3) LIGHT STRAW-CLAY WALL WITH BLIND STUDS
671 SECTION AR104 THERMAL PERFORMANCE
SECTION AR105 REFERENCED STANDARDS
TABLE AR105.1 REFERENCED STANDARDS
672 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AS – STRAWBALE CONSTRUCTION
APPENDIX AS STRAWBALE CONSTRUCTION
SECTION AS101 GENERAL
SECTION AS102 DEFINITIONS
673 FIGURE AS101.2 TYPICAL STRAWBALE WALL SYSTEMS
674 FIGURE AS102.1 BALE ORIENTATIONS
SECTION AS103 BALES
675 FIGURE AS103.2 APPROXIMATE DIMENSIONS OF COMMON STRAW BALES
SECTION AS104 FINISHES
676 SECTION AS105 STRAWBALE WALLS—GENERAL
677 FIGURE AS105.1(1) TYPICAL BASE OF PLASTERED STRAWBALE WALL ON CONCRETE SLAB AND FOOTING
678 FIGURE AS105.1(2) TYPICAL BASE OF PLASTERED STRAWBALE WALL OVER RAISED FLOOR
679 FIGURE AS105.1(3) TYPICAL TOP OF LOAD-BEARING STRAWBALE WALL
680 FIGURE AS105.1(4) TYPICAL TOP OF POST-AND-BEAM WALL WITH PLASTERED STRAWBALE INFILL
681 TABLE AS105.4 OUT-OF-PLANE RESISTANCE METHODS AND UNRESTRAINED WALL DIMENSION LIMITS
682 SECTION AS106 STRAWBALE WALLS—STRUCTURAL
683 TABLE AS106.6.1 MINIMUM COMPRESSIVE STRENGTH FOR PLASTERS ON STRUCTURAL WALLS
684 EQUATION AS-1
TABLE AS106.12 ALLOWABLE SUPERIMPOSED VERTICAL LOADS (LBS/FOOT) FOR PLASTERED LOAD-BEARING STRAWBALE WALLS
685 TABLE AS106.13(1) PLASTERED STRAWBALE BRACED WALL PANEL TYPES
686 TABLE AS106.13(2) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON WIND SPEED
687 TABLE AS106.13(3) BRACING REQUIREMENTS FOR STRAWBALE BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY
688 SECTION AS107 FIRE RESISTANCE
SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
TABLE AS109.1 REFERENCED STANDARDS
690 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AT – SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
APPENDIX AT [RE] SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION AT101 (RB101) SCOPE
SECTION AT102 (RB102) GENERAL DEFINITION
SECTION AT103 (RB103) SOLAR-READY ZONE
692 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AU – COB CONSTRUCTION (MONOLITHIC ADOBE)
APPENDIX AU COB CONSTRUCTION (MONOLITHIC ADOBE)
SECTION AU101 GENERAL
SECTION AU102 DEFINITIONS
693 FIGURE AU101.4 TYPICAL COB WALL
SECTION AU103 MATERIALS, MIXING AND INSTALLATION
694 SECTION AU104 FINISHES
695 SECTION AU105 COB WALLS—GENERAL
696 TABLE AU105.3 OUT-OF-PLANE RESISTANCE METHODS AND UNRESTRAINED WALL HEIGHT LIMITS
697 SECTION AU106 COB WALLS—STRUCTURAL
EQUATION AU-1
698 EQUATION AU-2
EQUATION AU-3
699 FIGURE AU106.9.5 CONNECTION OF ROOF FRAMING TO BOND BEAMS
700 FIGURE AU106.9.6 CONNECTIONS AT GABLE AND SHED ROOF END WALLS
701 TABLE AU106.10 LINTELS AND BOND BEAMS SPANNING OPENINGS
702 TABLE AU106.11(1) COB BRACED WALL PANEL TYPES
703 TABLE AU106.11(2) BRACING REQUIREMENTS FOR COB BRACED WALL PANELS BASED ON WIND SPEED
TABLE AU106.11(3) BRACING REQUIREMENTS FOR COB BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY A
704 TABLE AU106.11(4) BRACING REQUIREMENTS FOR COB BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY B
705 TABLE AU106.11(5) BRACING REQUIREMENTS FOR COB BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY C
706 EQUATION AU-4
FIGURE AU106.11.3 CURVED BRACED WALL PANEL
SECTION AU107 COB FLOORS
SECTION AU108 FIRE RESISTANCE
707 TABLE AU106.12 ANCHORAGE OF BOND BEAMS FOR WIND UPLIFT
SECTION AU109 THERMAL PERFORMANCE
SECTION AU110 REFERENCED STANDARDS
TABLE AU110.1 REFERENCED STANDARDS
708 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AV – BOARD OF APPEALS
APPENDIX AV BOARD OF APPEALS
SECTION AV101 GENERAL
710 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AW – 3D-PRINTED BUILDING CONSTRUCTION
APPENDIX AW 3D-PRINTED BUILDING CONSTRUCTION
SECTION AW101 GENERAL
SECTION AW102 DEFINITIONS
SECTION AW103 BUILDING DESIGN
711 SECTION AW104 BUILDING CONSTRUCTION
SECTION AW105 SPECIAL INSPECTIONS
SECTION AW106 REFERENCED STANDARDS
TABLE AW106.1 REFERENCED STANDARDS
712 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AX – SWIMMING POOL SAFETY ACT
APPENDIX AX SWIMMING POOL SAFETY ACT
AX100 CALIFORNIA SWIMMING POOL SAFETY ACT (STATEWIDE)
716 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AY – AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
APPENDIX AY AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
AY101 GENERAL
AY102 DEFINITIONS
717 AY103 STRUCTURAL STABILITY
AY104 EVACUATION LOCATIONS
AY105 SPACE WITHIN THE BUILDING
718 AY106 DECKS AND BALCONIES THAT ARE EVACUATION LOCATIONS
AY107 ROOFTOP EVACUATION LOCATIONS
AY108 ATTICS THAT ARE EVACUATION LOCATIONS
AY109 ALTERNATE MEANS OF PROTECTION
719 FIGURE K103.1 N.T.S.
720 FIGURE K103.1 N.T.S.
722 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX AZ – EMERGENCY HOUSING
APPENDIX AZ EMERGENCY HOUSING
SECTION AZ101 GENERAL
SECTION AZ102 DEFINITIONS
723 SECTION AZ103 EMERGENCY HOUSING
SECTION AZ104 EMERGENCY SLEEPING CABINS
724 SECTION AZ105 EMERGENCY TRANSPORTABLE HOUSING UNITS
SECTION AZ106 TENTS AND MEMBRANE STRUCTURES
SECTION AZ107 ACCESSIBILITY
SECTION AZ108 LOFTS IN EMERGENCY HOUSING
725 SECTION AZ109 LOCATION, MAINTENANCE AND IDENTIFICATION
SECTION AZ110 EMERGENCY HOUSING FACILITIES
728 INDEX
738 HISTORY NOTE APPENDIX
740 CODE RESOURCES FROM ICC
741 ICC ASSESSMENT CENTER
CA Residential Code Title 24 Part 2.5 2022 1stptg
$86.13