Shopping Cart

No products in the cart.

CA ResidentialCode 2019

$78.00

California Residential Code, Title 24, Part 2.5 (W/ ERRATA & SUPPLEMENT)

Published By Publication Date Number of Pages
CA 2019 679
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

California Residential Code (CRC) contains building provisions that cover construction of one- and two-family dwellings and townhouses that are three stories or less. This is a fully integrated code based on the 2018 International Residential Code® (Chapters 2-10). California amendments provide consistency with model code format, state and federal laws and regulations, and unique California conditions with regard to the construction of one- and two- family dwellings and townhouses. This code does not include Energy, Mechanical, Plumbing, or Electrical standards, which are found in other parts of Title 24.

PDF Catalog

PDF Pages PDF Title
1 2019 CALIFORNIA RESIDENTIAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2.5
2 2019 CALIFORNIA RESIDENTIAL CODE CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 2.5 TITLE PAGE
3 COPYRIGHT
4 PREFACE
ACKNOWLEDGEMENTS
5 CALIFORNIA CODE OF REGUALTIONS, TITLE 24 CALIFORNIA AGENCY INFORMATION CONTACT LIST
6 HOW TO DISTINGUISH BETWEEN MODEL CODE LANGUAGE AND CALIFORNIA AMENDMENTS
8 CALIFORNIA MATRIX ADOPTION TABLES
12 EFFECTIVE USE OF THE INTERNATIONAL RESIDENTIAL CODE
22 TABLE OF CONTENTS
26 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 1 – SCOPE AND APPLICATION
28 PART I—ADMINISTRATIVE
CHAPTER 1 SCOPE AND APPLICATION
DIVISION I CALIFORNIA ADMINISTRATION
SECTION 1.1 GENERAL
30 SECTION 1.2 RESERVED
SECTION 1.3 RESERVED
SECTION 1.4 RESERVED
SECTION 1.5 RESERVED
SECTION 1.6 RESERVED
SECTION 1.7 RESERVED
SECTION 1.8 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT (HCD)
SECTION 1.8.2 AUTHORITY AND ABBREVIATIONS
32 SECTION 1.8.3 LOCAL ENFORCING AGENCY
SECTION 1.8.4 PERMITS, FEES, APPLICATIONS AND INSPECTIONS
33 SECTION 1.8.5 RIGHT OF ENTRY FOR ENFORCEMENT
SECTION 1.8.6 LOCAL MODIFICATION BY ORDINANCE OR REGULATION
34 SECTION 1.8.7 ALTERNATE MATERIALS, DESIGNS, TESTS AND METHODS OF CONSTRUCTION
SECTION 1.8.8 APPEALS BOARD
35 SECTION 1.8.9 UNSAFE BUILDINGS OR STRUCTURES
36 SECTION 1.8.10 OTHER BUILDING REGULATIONS
SECTION 1.9 RESERVED
SECTION 1.10 RESERVED
SECTION 1.11 OFFICE OF THE STATE FIRE MARSHAL
40 SECTION 1.12 RESERVED
SECTION 1.13 RESERVED
SECTION 1.14 RESERVED
42 DIVISION II ADMINISTRATION
SECTION R101 GENERAL
SECTION R102 APPLICABILITY
43 SECTION R103 DEPARTMENT OF BUILDING SAFETY
SECTION R104 DUTIES AND POWERS OF THE BUILDING OFFICIAL
44 SECTION R105 PERMITS
46 SECTION R106 CONSTRUCTION DOCUMENTS
47 SECTION R107 TEMPORARY STRUCTURES AND USES
48 SECTION R108 FEES
SECTION R109 INSPECTIONS
49 SECTION R110 CERTIFICATE OF OCCUPANCY
50 SECTION R111 SERVICE UTILITIES
SECTION R112 BOARD OF APPEALS
SECTION R113 VIOLATIONS
SECTION R114 STOP WORK ORDER
52 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS
53 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLECHAPTER 2 – DEFINITIONS—continued
54 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
55 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 2 – DEFINITIONS—continued
56 PART II—DEFINITIONS
CHAPTER 2 DEFINITIONS
SECTION R201 GENERAL
SECTION R202 DEFINITIONS
70 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING
71 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 3 – BUILDING PLANNING—continued
72 PART III—BUILDING PLANNING AND CONSTRUCTION
CHAPTER 3 BUILDING PLANNING
SECTION R300 SITE DRAINAGE
SECTION R301 DESIGN CRITERIA
75 TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
76 TABLE R301.2.2.1.1 SEISMIC DESIGN CATEGORY DETERMINATION
77 TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
78 TABLE R301.2(2) COMPONENT AND CLADDING LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (ASD) (psf)
79 TABLE R301.2(3) HEIGHT AND EXPOSURE ADJUSTMENT COEFFICIENTS FOR TABLE R301.2(2)
FIGURE R301.2(1) ISOLINES OF THE 97 1/2 -PERCENT WINTER (DECEMBER, JANUARY AND FEBRUARY) DESIGN TEMPERATURES (°F)
80 FIGURE R301.2(2) SEISMIC DESIGN CATEGORIES
81 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
82 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
83 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
84 FIGURE R301.2(2)—continued SEISMIC DESIGN CATEGORIES
85 FIGURE R301.2(3) ALTERNATE SEISMIC DESIGN CATEGORIES
86 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
87 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
88 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
89 FIGURE R301.2(3)—continued ALTERNATE SEISMIC DESIGN CATEGORIES
90 FIGURE R301.2(4) WEATHERING PROBABILITY MAP FOR CONCRETE
91 FIGURE R301.2(5)A ULTIMATE DESIGN WIND SPEEDS
92 FIGURE R301.2(5)B REGIONS WHERE WIND DESIGN IS REQUIRED
FIGURE R301.2(5) BREGIONS WHERE WIND DESIGN IS REQUIRED
93 FIGURE R301.2(6) GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
94 FIGURE R301.2(6)—continued GROUND SNOW LOADS, Pg, FOR THE UNITED STATES (lb/ft2)
95 FIGURE R301.2(7) TERMITE INFESTATION PROBABILITY MAP
96 FIGURE R301.2(8) COMPONENT AND CLADDING PRESSURE ZONES
TABLE R301.2.1.3 WIND SPEED CONVERSIONS
97 TABLE R301.2.1.5.1 ULTIMATE DESIGN WIND SPEED MODIFICATION FOR TOPOGRAPHIC WIND EFFECT
FIGURE R301.2.1.5.1(1) TOPOGRAPHIC FEATURES FOR WIND SPEED-UP EFFECT
FIGURE R301.2.1.5.1(2) ILLUSTRATION OF WHERE ON A TOPOGRAPHIC FEATURE, WIND SPEED INCREASE IS APPLIED
98 FIGURE R301.2.1.5.1(3) UPWIND OBSTRUCTION
100 TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot)
101 TABLE R301.6 MINIMUM ROOF LIVE LOADS IN POUNDS-FORCE PER SQUARE FOOT OF HORIZONTAL PROJECTION
TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERS
SECTION R302 FIRE-RESISTANT CONSTRUCTION
102 TABLE R302.1(1) EXTERIOR WALLS
TABLE R302.1(2) EXTERIOR WALLS—DWELLINGS AND ACCESSORY BUILDINGS WITH AUTOMATIC RESIDENTIAL FIRE SPRINKLER PROTECTION
105 TABLE R302.6 DWELLING-GARAGE AND/OR CARPORT SEPARATION
107 SECTION R303 LIGHT, VENTILATION AND HEATING
108 SECTION R304 MINIMUM ROOM AREAS
109 SECTION R305 CEILING HEIGHT
SECTION R306 SANITATION
SECTION R307 TOILET, BATH AND SHOWER SPACES
SECTION R308 GLAZING
110 TABLE R308.3.1(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR 1201
TABLE R308.3.1(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
111 FIGURE R308.4.7 HAZARDOUS GLAZING LOCATIONS AT BOTTOM STAIR LANDINGS
112 SECTION R309 GARAGES AND CARPORTS
113 SECTION R310 EMERGENCY ESCAPE AND RESCUE OPENINGS
115 SECTION R311 MEANS OF EGRESS
118 SECTION R312 GUARDS AND WINDOW FALL PROTECTION
119 SECTION R313 AUTOMATIC FIRE SPRINKLER SYSTEMS
120 TABLE R313.3.2.2 LOCATIONS WHERE INTERMEDIATE TEMPERATURE SPRINKLERS ARE REQUIRED
121 FIGURE R313.3.2.4.2 MINIMUM ALLOWABLE DISTANCE BETWEEN SPRINKLER AND OBSTRUCTION
123 EQUATION 29-1
124 TABLE R313.3.6.2(1) WATER SERVICE PRESSURE LOSS (PLsvc)a, b
125 TABLE R313.3.6.2(2) MINIMUM WATER METER PRESSURE LOSS (PLm)a
TABLE R313.3.6.2(3) ELEVATION LOSS (PLe)
126 TABLE R313.3.6.2(4) ALLOWABLE PIPE LENGTH FOR 3/4-INCH TYPE M COPPER WATER TUBING
127 TABLE R313.3.6.2(5) ALLOWABLE PIPE LENGTH FOR 1-INCH TYPE M COPPER WATER TUBING
128 TABLE R313.3.6.2(6) ALLOWABLE PIPE LENGTH FOR 3/4-INCH CPVC PIPE
129 TABLE R313.3.6.2(7) ALLOWABLE PIPE LENGTH FOR 1-INCH CPVC PIPE
130 TABLE R313.3.6.2(8) ALLOWABLE PIPE LENGTH FOR 3/4-INCH PEX AND PE-RT TUBING
131 TABLE R313.3.6.2(9) ALLOWABLE PIPE LENGTH FOR 1-INCH PEX AND PE-RT TUBING
132 SECTION R314 SMOKE ALARMS
136 SECTION R315 CARBON MONOXIDE ALARMS
137 SECTION R316 FOAM PLASTIC
140 SECTION R317 PROTECTION OF WOOD AND WOOD-BASED PRODUCTS AGAINST DECAY
141 SECTION R318 PROTECTION AGAINST SUBTERRANEAN TERMITES
142 SECTION R319 SITE ADDRESS
SECTION R320 ACCESSIBILITY
SECTION R321 ELEVATORS AND PLATFORM LIFTS
SECTION R322 FLOOD-RESISTANT CONSTRUCTION
146 SECTION R323 STORM SHELTERS
SECTION 324 SOLAR ENERGY SYSTEMS
147 SECTION R325 MEZZANINES
148 SECTION R326 RESERVED
SECTION R327 STATIONARY STORAGE BATTERY SYSTEMS
SECTION R334 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING
SECTION R335 SPECIAL PROVISIONS FOR LICENSED 24-HOUR CARE FACILITIES IN A GROUP R-3.1
152 SECTION R336 LARGE FAMILY DAY-CARE HOMES
153 SECTION R337 MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE
SECTION R337.1 SCOPE, PURPOSE AND APPLICATION
154 SECTION R337.2 DEFINITIONS
155 SECTION R337.3 STANDARDS OF QUALITY
156 SECTION R337.4 IGNITION-RESISTANT CONSTRUCTION
SECTION R337.5 ROOFING
157 SECTION R337.6 VENTS
SECTION R337.7 EXTERIOR COVERING
160 SECTION R337.8 EXTERIOR WINDOWS, SKYLIGHTS AND DOORS
161 SECTION R337.9 DECKING
SECTION R337.10 ACCESSORY STRUCTURES
162 SECTION R338 ELECTRIC VEHICLE
SECTION R340 POLLUTANT CONTROL
164 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 4 – FOUNDATIONS
166 CHAPTER 4 FOUNDATIONS
SECTION R401 GENERAL
TABLE R401.4.1 PRESUMPTIVE LOAD-BEARING VALUES OF FOUNDATION MATERIALSa
167 SECTION R402 MATERIALS
168 TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE
SECTION R403 FOOTINGS
169 TABLE R403.1(1) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION
170 TABLE R403.1(2) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS FOR LIGHT-FRAME CONSTRUCTION WITH BRICK VENEER
171 TABLE R403.1(3) MINIMUM WIDTH AND THICKNESS FOR CONCRETE FOOTINGS WITH CAST-IN-PLACE CONCRETE OR FULLY GROUTED MASONRY WALL CONSTRUCTION
172 FIGURE R403.1(1) PLAIN CONCRETE FOOTINGS WITH MASONRY AND CONCRETE STEM WALLS IN SDC A, B AND C
173 FIGURE R403.1(2) PERMANENT WOOD FOUNDATION BASEMENT WALL SECTION
174 FIGURE R403.1(3) PERMANENT WOOD FOUNDATION CRAWL SPACE SECTION
175 FIGURE R403.1.3 REINFORCED CONCRETE FOOTINGS AND MASONRY AND CONCRETE STEM WALLS IN SDC D0, D1 AND D2
178 FIGURE R403.1.7.1 FOUNDATION CLEARANCE FROM SLOPES
179 FIGURE R403.3(1) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGS
TABLE R403.3(1) MINIMUM FOOTING DEPTH AND INSULATION REQUIREMENTS FOR FROST-PROTECTED FOOTINGS IN HEATED BUILDINGSa
180 FIGURE R403.3(2) AIR-FREEZING INDEX AN ESTIMATE OF THE 100-YEAR RETURN PERIOD
181 TABLE R403.3(2) AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
182 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
183 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
184 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
185 TABLE R403.3(2)—continued AIR-FREEZING INDEX FOR U.S. LOCATIONS BY COUNTY
186 FIGURE R403.3(3) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO UNHEATED SLAB-ON-GROUND STRUCTURE
FIGURE R403.3(4) INSULATION PLACEMENT FOR FROST-PROTECTED FOOTINGS ADJACENT TO HEATED STRUCTURE
187 TABLE R403.4 MINIMUM DEPTH (D) AND WIDTH (W) OF CRUSHED STONE FOOTINGSa, b (inches)
188 FIGURE R403.4(1) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL BEARING ON CRUSHED STONE
FIGURE R403.4(2) BASEMENT OR CRAWL SPACE WITH PRECAST FOUNDATION WALL ON SPREAD FOOTING
SECTION R404 FOUNDATION AND RETAINING WALLS
189 TABLE R404.1.1(1) PLAIN MASONRY FOUNDATION WALLSf
190 TABLE R404.1.1(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  5 INCHES
191 TABLE R404.1.1(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  6.75 INCHES
192 TABLE R404.1.1(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCING WHERE d  8.75 INCHES
193 TABLE R404.1.2(1) MINIMUM HORIZONTAL REINFORCEMENT FOR CONCRETE BASEMENT WALLS
TABLE R404.1.2(2) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
194 TABLE R404.1.2(3) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH (203 mm) NOMINAL FLAT CONCRETE BASEMENT WALLS
195 TABLE R404.1.2(4) MINIMUM VERTICAL REINFORCEMENT FOR 10-INCH NOMINAL FLAT CONCRETE BASEMENT WALLS
196 TABLE R404.1.2(5) MINIMUM VERTICAL WALL REINFORCEMENT FOR 6-INCH WAFFLE-GRID BASEMENT WALLS
197 TABLE R404.1.2(6) MINIMUM VERTICAL REINFORCEMENT FOR 8-INCH WAFFLE-GRID BASEMENT WALLS
198 TABLE R404.1.2(7) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH (152 mm) SCREEN-GRID BASEMENT WALLS
199 TABLE R404.1.2(8) MINIMUM VERTICAL REINFORCEMENT FOR 6-, 8-, 10- AND 12-INCH NOMINAL FLAT BASEMENT WALLS
200 TABLE R404.1.2(9) MINIMUM SPACING FOR ALTERNATE BAR SIZE AND ALTERNATE GRADE OF STEEL
205 FIGURE R404.1.5(1) FOUNDATION WALL CLAY MASONRY CURTAIN WALL WITH CONCRETE MASONRY PIERS
207 TABLE R404.2.3 PLYWOOD GRADE AND THICKNESS FOR WOOD FOUNDATION CONSTRUCTION (30 pcf equivalent-fluid weight soil pressure)
SECTION R405 FOUNDATION DRAINAGE
208 TABLE R405.1 PROPERTIES OF SOILS CLASSIFIED ACCORDING TO THE UNIFIED SOIL CLASSIFICATION SYSTEM
209 SECTION R406 FOUNDATION WATERPROOFING AND DAMPPROOFING
SECTION R407 COLUMNS
210 SECTION R408 UNDER-FLOOR SPACE
212 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 5 – FLOORS
214 CHAPTER 5 FLOORS
SECTION R501 GENERAL
SECTION R502 WOOD FLOOR FRAMING
215 FIGURE R502.2 FLOOR CONSTRUCTION
216 TABLE R502.3.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
217 TABLE R502.3.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)a
218 TABLE R502.3.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
219 TABLE R502.3.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)b
221 TABLE R502.3.3(1) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING LIGHT-FRAME EXTERIOR BEARING WALL AND ROOF ONLY Floor Live Load ≤ 40 psf, Roof Live Load ≤ 20 psf)
TABLE R502.3.3(2) CANTILEVER SPANS FOR FLOOR JOISTS SUPPORTING EXTERIOR BALCONY
222 FIGURE R502.8 CUTTING, NOTCHING AND DRILLING
223 SECTION R503 FLOOR SHEATHING
TABLE R503.1 MINIMUM THICKNESS OF LUMBER FLOOR SHEATHING
TABLE R503.2.1.1(2) ALLOWABLE SPANS FOR SANDED PLYWOOD COMBINATION SUBFLOOR UNDERLAYMENTa
224 TABLE R503.2.1.1(1) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF AND SUBFLOOR SHEATHING AND COMBINATION SUBFLOOR UNDERLAYMENT
SECTION R504 PRESSURE PRESERVATIVE- TREATED WOOD FLOORS (ON GROUND)
225 SECTION R505 COLD-FORMED STEEL FLOOR FRAMING
226 FIGURE R505.1.2 IN-LINE FRAMING
227 TABLE R505.2.3 COLD-FORMED STEEL JOIST SIZES AND THICKNESS
FIGURE R505.2.3(1) C-SHAPED SECTION
FIGURE R505.2.3(2) TRACK SECTION
228 FIGURE R505.2.6.1 FLOOR JOIST WEB HOLES
FIGURE R505.2.6.3 FLOOR JOIST WEB HOLE PATCH
229 TABLE R505.3.1(1) FLOOR-TO-FOUNDATION OR BEARING WALL CONNECTION REQUIREMENTS
FIGURE R505.3.1(1) FLOOR-TO-EXTERIOR LOAD-BEARING WALL STUD CONNECTION
231 TABLE R505.3.1(2) FLOOR FASTENING SCHEDULEa
FIGURE R505.3.1(2) FLOOR-TO-WOOD-SILL CONNECTION
232 FIGURE R505.3.1(3) FLOOR-TO-FOUNDATION CONNECTION
FIGURE R505.3.1(4) CANTILEVERED FLOOR-TO-FOUNDATION CONNECTION
233 FIGURE R505.3.1(5) CANTILEVERED FLOOR-TO-WOOD-SILL CONNECTION
FIGURE R505.3.1(6) CANTILEVERED FLOOR TO EXTERIOR LOAD-BEARING WALL CONNECTION
234 FIGURE R505.3.1(7) CONTINUOUS SPAN JOIST SUPPORTED ON INTERIOR LOAD-BEARING WALL
235 FIGURE R505.3.1(8) LAPPED JOISTS SUPPORTED ON INTERIOR LOAD-BEARING WALL
FIGURE R505.3.1(9) BEARING STIFFENERS FOR END JOISTS
236 TABLE R505.3.2 ALLOWABLE SPANS FOR COLD-FORMED STEEL JOISTS—SINGLE OR CONTINUOUS SPAN
SECTION R506 CONCRETE FLOORS (ON GROUND)
237 FIGURE R505.3.3.2(1) JOIST BLOCKING (SOLID)
FIGURE R505.3.3.2(2) JOIST BLOCKING (STRAP)
238 FIGURE R505.3.4(1) BEARING STIFFENERS UNDER JAMB STUDS
FIGURE R505.3.4(2) BEARING STIFFENER
239 FIGURE R505.3.7 TRACK SPLICE
FIGURE R505.3.8(1) COLD-FORMED STEEL FLOOR CONSTRUCTION—6-FOOT FLOOR OPENING
240 FIGURE R505.3.8(2) COLD-FORMED STEEL FLOOR CONSTRUCTION—8-FOOT FLOOR OPENING
FIGURE R505.3.8(3) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—6-FOOT OPENING
241 FIGURE R505.3.8(4) COLD-FORMED STEEL FLOOR CONSTRUCTION: FLOOR HEADER TO TRIMMER CONNECTION—8-FOOT OPENING
SECTION R507 EXTERIOR DECKS
242 TABLE R507.2.3 FASTENER AND CONNECTOR SPECIFICATIONS FOR DECKS
TABLE R507.4 DECK POST HEIGHTa
243 FIGURE R507.3 DECK POSTS TO DECK FOOTING CONNECTION
244 TABLE R507.3.1 MINIMUM FOOTING SIZE FOR DECKS
245 FIGURE R507.5 TYPICAL DECK JOIST SPANS
TABLE R507.5 DECK BEAM SPAN LENGTHS (feet – inches)
246 FIGURE R507.5.1(1) DECK BEAM TO DECK POST
FIGURE R507.5.1(2) NOTCHED POST-TO-BEAM CONNECTION
247 FIGURE R507.6 TYPICAL DECK JOIST SPANS
248 TABLE R507.6 DECK JOIST SPANS FOR COMMON LUMBER SPECIES (ft. – in.)
TABLE R507.7 MAXIMUM JOIST SPACING FOR DECKING
249 TABLE R507.9.1.3(1) DECK LEDGER CONNECTION TO BAND JOIST (Deck live load = 40 psf, deck dead load = 10 psf, snow load ≤ 40 psf)
250 TABLE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN DECK LEDGERS AND BAND JOISTS
FIGURE R507.9.1.3(1) PLACEMENT OF LAG SCREWS AND BOLTS IN LEDGERS
FIGURE R507.9.1.3(2) PLACEMENT OF LAG SCREWS AND BOLTS IN BAND JOISTS
251 FIGURE R507.9.2(1) DECK ATTACHMENT FOR LATERAL LOADS
FIGURE R507.9.2(2) DECK ATTACHMENT FOR LATERAL LOADS
252 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 6 – WALL CONSTRUCTION
254 CHAPTER 6 WALL CONSTRUCTION
SECTION R601 GENERAL
SECTION R602 WOOD WALL FRAMING
255 TABLE R602.3(1) FASTENING SCHEDULE
256 TABLE R602.3(1)—continued FASTENING SCHEDULE
257 TABLE 602.3(1) FASTENING SCHEDULE—continued
258 TABLE R602.3(1)—continued FASTENING SCHEDULE
259 TABLE R602.3.2 SINGLE TOP-PLATE SPLICE CONNECTION DETAILS
260 TABLE R602.3(2) ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
261 TABLE R602.3(2)—continued ALTERNATE ATTACHMENTS TO TABLE R602.3(1)
TABLE R602.3(3) REQUIREMENTS FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
TABLE R602.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHINGa
262 TABLE R602.3(5) SIZE, HEIGHT AND SPACING OF WOOD STUDSa
TABLE R602.3(6) ALTERNATE WOOD BEARING WALL STUD SIZE, HEIGHT AND SPACING
263 FIGURE R602.3(1) TYPICAL WALL, FLOOR AND ROOF FRAMING
264 FIGURE R602.3(2) FRAMING DETAILS
265 FIGURE R602.6(1) NOTCHING AND BORED HOLE LIMITATIONS FOR EXTERIOR WALLS AND BEARING WALLS
266 FIGURE R602.6(2) NOTCHING AND BORED HOLE LIMITATIONS FOR INTERIOR NONBEARING WALLS
FIGURE R602.6.1 TOP PLATE FRAMING TO ACCOMMODATE PIPING
267 TABLE R602.7(1) GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
268 TABLE R602.7(1)—continued GIRDER SPANSa AND HEADER SPANSa FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
269 TABLE R602.7(2) GIRDER SPANSa AND HEADER SPANSa FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, southern pine and spruce-pine-firb and required number of jack studs)
TABLE R602.7(3) GIRDER AND HEADER SPANSa FOR OPEN PORCHES (Maximum span for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb)
270 FIGURE R602.7.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE R602.7.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
FIGURE R602.7.2 RIM BOARD HEADER CONSTRUCTION
271 TABLE R602.7.5 MINIMUM NUMBER OF FULL-HEIGHT STUDS AT EACH END OF HEADERS IN EXTERIOR WALLSa
272 TABLE R602.7.3 MAXIMUM SPANS FOR WOOD STRUCTURAL PANEL BOX HEADERSa
FIGURE R602.7.3 TYPICAL WOOD STRUCTURAL PANEL BOX HEADER CONSTRUCTION
273 FIGURE R602.10.1.1 BRACED WALL LINES
TABLE R602.10.1.3 BRACED WALL LINE SPACING
274 FIGURE R602.10.1.4 ANGLED WALLS
FIGURE R602.10.2.2 LOCATION OF BRACED WALL PANELS
276 TABLE R602.10.3(1) BRACING REQUIREMENTS BASED ON WIND SPEED
277 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
278 TABLE R602.10.3(1)—continued BRACING REQUIREMENTS BASED ON WIND SPEED
279 TABLE R602.10.3(2) WIND ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
280 TABLE R602.10.3(3) BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
281 TABLE R602.10.3(3)—continued BRACING REQUIREMENTS BASED ON SEISMIC DESIGN CATEGORY
282 TABLE R602.10.3(4) SEISMIC ADJUSTMENT FACTORS TO THE REQUIRED LENGTH OF WALL BRACING
283 TABLE R602.10.4 BRACING METHODS
284 TABLE R602.10.4—continued BRACING METHODS
286 TABLE R602.10.5 MINIMUM LENGTH OF BRACED WALL PANELS
287 FIGURE R602.10.5 BRACED WALL PANELS WITH CONTINUOUS SHEATHING
TABLE R602.10.5.2 PARTIAL CREDIT FOR BRACED WALL PANELS LESS THAN 48 INCHES IN ACTUAL LENGTH
TABLE R602.10.6.1 MINIMUM HOLD-DOWN FORCES FOR METHOD ABW BRACED WALL PANELS
288 FIGURE R602.10.6.1 METHOD ABW—ALTERNATE BRACED WALL PANEL
FIGURE R602.10.6.2 METHOD PFH—PORTAL FRAME WITH HOLD-DOWNS
289 FIGURE R602.10.6.3 METHOD PFG—PORTAL FRAME AT GARAGE DOOR OPENINGS IN SEISMIC DESIGN CATEGORIES A, B AND C
290 FIGURE R602.10.6.4 METHOD CS-PF—CONTINUOUSLY SHEATHED PORTAL FRAME PANEL CONSTRUCTION
291 TABLE R602.10.6.4 TENSION STRAP CAPACITY FOR RESISTING WIND PRESSURES PERPENDICULAR TO METHODS PFH, PFG AND CS-PF BRACED WALL PANELSa
292 TABLE R602.10.6.5 METHOD BV-WSP WALL BRACING REQUIREMENTS
293 FIGURE R602.10.6.5 METHOD BV-WSP—WALL BRACING FOR DWELLINGS WITH STONE AND MASONRY VENEER IN SEISMIC DESIGN CATEGORIES D0, D1 and D2
294 FIGURE R602.10.7 END CONDITIONS FOR BRACED WALL LINES WITH CONTINUOUS SHEATHING
295 FIGURE R602.10.8(1) BRACED WALL PANEL CONNECTION WHEN PERPENDICULAR TO FLOOR/CEILING FRAMING
296 FIGURE R602.10.8(2) BRACED WALL PANEL CONNECTION WHEN PARALLEL TO FLOOR/CEILING FRAMING
FIGURE R602.10.8.2(1) BRACED WALL PANEL CONNECTION TO PERPENDICULAR RAFTERS
FIGURE R602.10.8.2(2) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
297 FIGURE R602.10.8.2(3) BRACED WALL PANEL CONNECTION OPTION TO PERPENDICULAR RAFTERS OR ROOF TRUSSES
298 FIGURE R602.10.9 MASONRY STEM WALLS SUPPORTING BRACED WALL PANELS
299 FIGURE R602.11.2 STEPPED FOUNDATION CONSTRUCTION
300 FIGURE R602.12.1 RECTANGLE CIRCUMSCRIBING AN ENCLOSED BUILDING
301 TABLE R602.12.4 MINIMUM NUMBER OF BRACING UNITS ON EACH SIDE OF THE CIRCUMSCRIBED RECTANGLE
302 FIGURE R602.12.5 BRACING UNIT DISTRIBUTION
SECTION R603 COLD-FORMED STEEL WALL FRAMING
303 FIGURE R603.1.2 IN-LINE FRAMING
304 FIGURE R603.2.3(1) C-SHAPED SECTION
FIGURE R603.2.3(2) TRACK SECTION
TABLE R603.2.3 LOAD-BEARING COLD-FORMED STEEL STUD SIZES AND THICKNESSES
305 FIGURE R603.2.6.1 WALL STUD WEB HOLES
FIGURE R603.2.6.3 WALL STUD WEB HOLE PATCH
306 TABLE R603.3.1 WALL TO FOUNDATION OR FLOOR CONNECTION REQUIREMENTS
307 TABLE R603.3.1.1(1) GABLE ENDWALL TO FLOOR CONNECTION REQUIREMENTS
TABLE R603.3.1.1(2) GABLE ENDWALL BOTTOM TRACK TO FOUNDATION CONNECTION REQUIREMENTS
FIGURE R603.3.1(1) WALL TO FLOOR CONNECTION
308 FIGURE R603.3.1(2) WALL TO FOUNDATION CONNECTION
FIGURE R603.3.1(3) WALL TO WOOD SILL CONNECTION
309 FIGURE R603.3.1(4) WIND UPLIFT CONNECTOR
TABLE R603.3.2(1) WALL FASTENING SCHEDULEa
310 TABLE R603.3.2(2) 24-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
311 TABLE R603.3.2(3) 28-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
312 TABLE R603.3.2(4) 32-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
313 TABLE R603.3.2(5) 36-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLYa, b, c, d
314 TABLE R603.3.2(6) 40-FOOT-WIDE BUILDING SUPPORTING ROOF AND CEILING ONLY
315 TABLE R603.3.2(7) 24-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
316 TABLE R603.3.2(8) 28-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
317 TABLE R603.3.2(9) 32-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
318 TABLE R603.3.2(10) 36-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
319 TABLE R603.3.2(11) 40-FOOT-WIDE BUILDING SUPPORTING ONE FLOOR, ROOF AND CEILING
320 TABLE R603.3.2(12) 24-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
321 TABLE R603.3.2(13) 28-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
322 TABLE R603.3.2(14) 32-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
323 TABLE R603.3.2(15) 36-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
324 TABLE R603.3.2(16) 40-FOOT-WIDE BUILDING SUPPORTING TWO FLOORS, ROOF AND CEILING
325 TABLE R603.3.2.1(1) ALL BUILDING WIDTHS GABLE ENDWALLS 8, 9 OR 10 FEET IN HEIGHT
326 TABLE R603.3.2.1(2) ALL BUILDING WIDTHS GABLE ENDWALLS OVER 10 FEET IN HEIGHT
327 FIGURE R603.3.3(1) STUD BRACING WITH STRAPPING ONLY
FIGURE R603.3.3(2) STUD BRACING WITH STRAPPING AND SHEATHING MATERIAL
328 FIGURE R603.3.5 TRACK SPLICE
FIGURE R603.4 CORNER FRAMING
329 FIGURE R603.6(1) BOX BEAM HEADER
FIGURE R603.6(2) BACK-TO-BACK HEADER
330 TABLE R603.6(1) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
331 TABLE R603.6(2) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Roof and Ceiling Onlya, b, d
332 TABLE R603.6(3) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
333 TABLE R603.6(4) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting One Floor, Roof and Ceilinga, b, d
334 TABLE R603.6(5) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
335 TABLE R603.6(6) BOX-BEAM AND BACK-TO-BACK HEADER SPANS Headers Supporting Two Floors, Roof and Ceilinga, b, d
336 FIGURE R603.6.1(1) BOX BEAM HEADER IN GABLE ENDWALL
FIGURE R603.6.1(2) BACK-TO-BACK HEADER IN GABLE ENDWALL
337 TABLE R603.7(1) TOTAL NUMBER OF JACK AND KING STUDS REQUIRED AT EACH END OF AN OPENING
TABLE R603.7(2) HEADER TO KING STUD CONNECTION REQUIREMENTS
TABLE R603.8 HEAD AND SILL TRACK SPAN
338 FIGURE R603.9 STRUCTURAL SHEATHING FASTENING PATTERN
339 TABLE R603.9.2(1) MINIMUM PERCENTAGE OF FULL-HEIGHT STRUCTURAL SHEATHING ON EXTERIOR WALLS
TABLE R603.9.2(2) FULL-HEIGHT SHEATHING LENGTH ADJUSTMENT FACTORS
FIGURE R603.9.4.2 CORNER STUD HOLD-DOWN DETAIL
340 TABLE R603.9.5(1) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
341 TABLE R603.9.5(2) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 6-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
342 TABLE R603.9.5(3) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 33-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
343 TABLE R603.9.5(4) REQUIRED LENGTH OF FULL-HEIGHT SHEATHING AND ASSOCIATED OVERTURNING ANCHORAGE FOR WALLS SUPPORTING WALLS WITH STONE OR MASONRY VENEER AND USING 43-MIL COLD-FORMED STEEL FRAMING AND 4-INCH SCREW SPACING ON THE PERIMETER OF EACH PANEL OF STRUCTURAL SHEATHING
SECTION R604 WOOD STRUCTURAL PANELS
SECTION R605 PARTICLEBOARD
SECTION R606 GENERAL MASONRY CONSTRUCTION
344 TABLE R606.2.8 MORTAR PROPORTIONS
345 TABLE R606.2.12 GROUT PROPORTIONS BY VOLUME FOR MASONRY CONSTRUCTION
346 TABLE R606.3.4.1 MINIMUM CORROSION PROTECTION
TABLE R606.3.5.1 GROUT SPACE DIMENSIONS AND POUR HEIGHTS
348 TABLE R606.6.4 SPACING OF LATERAL SUPPORT FOR MASONRY WALLS
349 TABLE R606.9 ALLOWABLE COMPRESSIVE STRESSES FOR EMPIRICAL DESIGN OF MASONRY
350 FIGURE R606.11(1) ANCHORAGE REQUIREMENTS FOR MASONRY WALLS LOCATED IN SEISMIC DESIGN CATEGORY A, B OR C AND WHERE WIND LOADS ARE LESS THAN 30 PSF
351 FIGURE R606.11(2) REQUIREMENTS FOR REINFORCED GROUTED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY C
352 FIGURE R606.11(3) REQUIREMENTS FOR REINFORCED MASONRY CONSTRUCTION IN SEISMIC DESIGN CATEGORY D0, D1 OR D2
353 TABLE R606.12.2.1 MINIMUM SOLID WALL LENGTH ALONG EXTERIOR WALL LINES
TABLE R606.12.3.2 MINIMUM DISTRIBUTED WALL REINFORCEMENT FOR BUILDINGS ASSIGNED TO SEISMIC DESIGN CATEGORY D0 or D1
354 TABLE R606.12.4.1 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
TABLE R606.12.4.2 MINIMUM REINFORCING FOR STACKED BONDED MASONRY WALLS IN SEISMIC DESIGN CATEGORY D2
355 SECTION R607 GLASS UNIT MASONRY
356 FIGURE R607.4.1 GLASS UNIT MASONRY DESIGN WIND LOAD RESISTANCE
357 SECTION R608 EXTERIOR CONCRETE WALL CONSTRUCTION
358 TABLE R608.3 DIMENSIONAL REQUIREMENTS FOR WALLSa
FIGURE R608.3(1) FLAT WALL SYSTEM
359 FIGURE R608.3(2) WAFFLE-GRID WALL SYSTEM
FIGURE R608.3(3) SCREEN-GRID WALL SYSTEM
361 TABLE R608.5.4(1) LAP SPLICE AND TENSION DEVELOPMENT LENGTHS
FIGURE R608.5.4(1) LAP SPLICES
362 FIGURE R608.5.4(2) DEVELOPMENT LENGTH AND COVER FOR HOOKS AND BAR EXTENSION6 d BENDDIAMETERbdb12 dEXTENSIONbdb6 d BENDDIAMETERb2 / IN., BUT NOTLESS THAN 4 d EXTENSION12bdb4 d
FIGURE R608.5.4(3) STANDARD HOOKS
363 TABLE R608.5.4(2) MAXIMUM SPACING FOR ALTERNATIVE BAR SIZE AND ALTERNATIVE GRADE OF STEEL
365 FIGURE R608.6(1) ABOVE-GRADE CONCRETE WALL CONSTRUCTION ONE STORY
FIGURE R608.6(2) ABOVE-GRADE CONCRETE WALL CONSTRUCTION CONCRETE FIRST STORY AND LIGHT-FRAMED SECOND STORY
FIGURE R608.6(3) ABOVE-GRADE CONCRETE WALL CONSTRUCTION TWO-STORY
FIGURE R608.6(4) ABOVE-GRADE CONCRETE WALL SUPPORTED ON MONOLITHIC SLAB-ON-GROUND FOOTING
366 TABLE R608.6(1) MINIMUM VERTICAL REINFORCEMENT FOR FLAT ABOVE-GRADE WALLS
367 TABLE R608.6(2) MINIMUM VERTICAL REINFORCEMENT FOR WAFFLE-GRID ABOVE-GRADE WALLS
368 TABLE R608.6(3) MINIMUM VERTICAL REINFORCEMENT FOR 6-INCH SCREEN-GRID ABOVE-GRADE WALLS
369 TABLE R608.6(4) MINIMUM VERTICAL REINFORCEMENT FOR FLAT, WAFFLE- AND SCREEN-GRID ABOVE-GRADE WALLS DESIGNED CONTINUOUS WITH FOUNDATION STEM WALLS
371 EQUATION R6-1
EQUATION R6-2
372 TABLE R608.7(1A) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY
373 TABLE R608.7(1A)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE ONE STORY OR TOP STORY OF TWO STORY
374 TABLE R608.7(1B) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY
375 TABLE R608.7(1B)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR ENDWALL FOR WIND PERPENDICULAR TO RIDGE FIRST STORY OF TWO STORY
376 TABLE R608.7(1C) UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
377 TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
TABLE R608.7(1C)—continued UNREDUCED LENGTH, UR, OF SOLID WALL REQUIRED IN EACH EXTERIOR SIDEWALL FOR WIND PARALLEL TO RIDGE
378 TABLE R608.7(2) REDUCTION FACTOR, R1, FOR BUILDINGS WITH MEAN ROOF HEIGHT LESS THAN 35 FEETa
TABLE R608.7(3) REDUCTION FACTOR, R2, FOR FLOOR-TO-CEILING WALL HEIGHTS LESS THAN 10 FEET
379 TABLE R608.7(4) REDUCTION FACTOR FOR DESIGN STRENGTH, R3, FOR FLAT, WAFFLE- AND SCREEN-GRID WALLS
380 FIGURE R608.7(1) MINIMUM SOLID WALL LENGTH
381 FIGURE R608.7(2) VERTICAL REINFORCEMENT LAYOUT DETAIL
382 FIGURE R608.7(3) VERTICAL WALL REINFORCEMENT ADJACENT TO WALL OPENINGS
383 FIGURE R608.8(1) REINFORCEMENT OF OPENINGS
384 FIGURE R608.8(2) LINTEL FOR FLAT WALLS
385 FIGURE R608.8(3) LINTELS FOR WAFFLE-GRID WALLS
386 FIGURE R608.8(4) LINTELS FOR SCREEN-GRID WALLS
387 TABLE R608.8(1) LINTEL DESIGN LOADING CONDITIONS
388 TABLE R608.8(2) MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
389 TABLE R608.8(2)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 4-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
390 TABLE R608.8(3) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
391 TABLE R608.8(3)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
392 TABLE R608.8(4) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
393 TABLE R608.8(4)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
394 TABLE R608.8(5) MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
395 TABLE R608.8(5)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 10-INCH-NOMINAL THICK FLAT LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, m ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
396 TABLE R608.8(6) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
397 TABLE R608.8(6)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR SPAN 32 FEET
398 TABLE R608.8(7) MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
399 TABLE R608.8(7)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR 8-INCH-THICK WAFFLE-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, o MAXIMUM ROOF CLEAR SPAN 40 FEET AND MAXIMUM FLOOR CLEAR SPAN 32 FEET
400 TABLE R608.8(8) MAXIMUM ALLOWABLE CLEAR SPANS FOR 6-INCH-THICK SCREEN-GRID LINTELS IN LOAD-BEARING WALLSa, b, c, d, e, f, p ROOF CLEAR SPAN 40 FEET AND FLOOR CLEAR SPAN 32 FEET
401 TABLE R608.8(9) MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
402 TABLE R608.8(9)—continued MAXIMUM ALLOWABLE CLEAR SPANS FOR FLAT LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
TABLE R608.8(10) MAXIMUM ALLOWABLE CLEAR SPANS FOR WAFFLE-GRID AND SCREEN-GRID LINTELS WITHOUT STIRRUPS IN NONLOAD-BEARING WALLS
404 FIGURE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
405 TABLE R608.9(1) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
406 FIGURE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
407 TABLE R608.9(2) WOOD-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
408 FIGURE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL FRAMING, PERPENDICULAR
409 TABLE R608.9(3) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
410 FIGURE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
411 TABLE R608.9(4) WOOD-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
412 FIGURE R608.9(5) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
413 TABLE R608.9(5) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PERPENDICULAR
414 FIGURE R608.9(6) COLD-FORMED STEEL FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
415 TABLE R608.9(6) COLD-FORMED STEEL-FRAMED FLOOR TO SIDE OF CONCRETE WALL, FRAMING PARALLEL
416 FIGURE R608.9(7) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
417 TABLE R608.9(7) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
418 FIGURE R608.9(8) COLD-FORMED STEEL FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
419 TABLE R608.9(8) COLD-FORMED STEEL-FRAMED FLOOR TO TOP OF CONCRETE WALL, FRAMING PARALLEL
420 FIGURE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
421 TABLE R608.9(9) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
422 FIGURE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
423 TABLE R608.9(10) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
424 FIGURE R608.9(11) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
425 TABLE R608.9(11) WOOD-FRAMED ROOF TO TOP OF CONCRETE WALL, FRAMING PERPENDICULAR
426 FIGURE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
427 TABLE R608.9(12) COLD-FORMED STEEL ROOF TO TOP OF CONCRETE WALL, FRAMING PARALLEL
428 SECTION R609 EXTERIOR WINDOWS AND DOORS
429 FIGURE R609.7.2(1) THROUGH THE FRAME
FIGURE R609.7.2(2) FRAME CLIP
FIGURE R609.7.2(3) THROUGH THE FRAME
FIGURE R609.7.2(4) FRAME CLIP
430 FIGURE R609.7.2(5) THROUGH THE FLANGE
FIGURE R609.7.2(6) THROUGH THE FLANGE
FIGURE R609.7.2(7) FRAME CLIP
FIGURE R609.7.2(8) THROUGH THE FLANGE
431 SECTION R610 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION
432 FIGURE R610.4 SIP WALL PANEL
433 TABLE R610.5(1) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ROOF ONLY (inches)a
434 TABLE R610.5(2) MINIMUM THICKNESS FOR SIP WALL SUPPORTING SIP OR LIGHT-FRAME ONE STORY AND ROOF ONLY (inches)a
435 FIGURE R610.5(1) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
FIGURE R610.5(2) MAXIMUM ALLOWABLE HEIGHT OF SIP WALLS
436 FIGURE R610.5(3) TRUSSED ROOF TO TOP PLATE CONNECTION
FIGURE R610.5(4) SIP WALL-TO-WALL PLATFORM FRAME CONNECTION
437 FIGURE R610.5(5) SIP WALL-TO-WALL HANGING FLOOR FRAME CONNECTION
FIGURE R610.5.1 SIP WALL FRAMING CONFIGURATION
438 FIGURE R610.5.2 SIP WALL TO CONCRETE SLAB FOR FOUNDATION WALL ATTACHMENT
FIGURE R610.5.4 SIP CORNER FRAMING DETAIL
439 FIGURE R610.8 TYPICAL SIP WALL PANEL-TO-PANEL CONNECTION DETAILS
TABLE R610.8 MAXIMUM SPANS FOR 11 7/8-INCH OR DEEPER SIP HEADERS
440 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 7 – WALL COVERING
442 CHAPTER 7 WALL COVERING
SECTION R701 GENERAL
SECTION R702 INTERIOR COVERING
TABLE R702.1(1) THICKNESS OF PLASTER
443 TABLE R702.1(2) GYPSUM PLASTER PROPORTIONSa
TABLE R702.1(3) CEMENT PLASTER PROPORTIONS, PARTS BY VOLUME
445 TABLE R702.3.5 MINIMUM THICKNESS AND APPLICATION OF GYPSUM BOARD AND GYPSUM PANEL PRODUCTS
446 TABLE R702.3.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
TABLE R702.4.2 BACKER BOARD MATERIALS
447 SECTION R703 EXTERIOR COVERING
448 TABLE R703.3(1) SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
449 TABLE R703.3(1)—continued SIDING MINIMUM ATTACHMENT AND MINIMUM THICKNESS
450 TABLE R703.3(2) SCREW FASTENER SUBSTITUTION FOR SIDING ATTACHMENT TO COLD-FORMED STEEL LIGHT FRAME CONSTRUCTION
TABLE R703.3.2 LIMITS FOR ATTACHMENT PER TABLE R703.3(1)
TABLE R703.3.3 OPTIONAL SIDING ATTACHMENT SCHEDULE FOR FASTENERS WHERE NO STUD PENETRATION NECESSARY
452 TABLE R703.6.1 MAXIMUM WEATHER EXPOSURE FOR WOOD SHAKES AND SHINGLES ON EXTERIOR WALLS
453 TABLE R703.6.3(1) SINGLE-COURSE SIDEWALL FASTENERS
TABLE R703.6.3(2) DOUBLE-COURSE SIDEWALL FASTENERS
454 FIGURE R703.8 TYPICAL MASONRY VENEER WALL DETAILSe
455 FIGURE R703.8—continued TYPICAL MASONRY VENEER WALL DETAILSe
456 TABLE R703.8(1) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, WOOD OR STEEL FRAMING, SEISMIC DESIGN CATEGORIES A, B AND C
TABLE R703.8(2) STONE OR MASONRY VENEER LIMITATIONS AND REQUIREMENTS, ONE- AND TWO-FAMILY DETACHED DWELLINGS, SEISMIC DESIGN CATEGORIES D0, D1 AND D2
457 FIGURE R703.8.2.1 EXTERIOR MASONRY VENEER SUPPORT BY STEEL ANGLES
FIGURE R703.8.2.2 EXTERIOR MASONRY VENEER SUPPORT BY ROOF MEMBERS
458 TABLE R703.8.3.1 ALLOWABLE SPANS FOR LINTELS SUPPORTING MASONRY VENEER
TABLE R703.8.3.2 HEIGHT OF MASONRY VENEER ABOVE OPENING
FIGURE R703.8.3.2 MASONRY VENEER OPENING
459 TABLE R703.8.4(1) TIE ATTACHMENT AND AIRSPACE REQUIREMENTS
460 TABLE R703.8.4(2) REQUIRED BRICK TIE SPACING FOR DIRECT APPLICATION TO WOOD STRUCTURAL PANEL SHEATHING
462 TABLE R703.11.2 ADJUSTED MINIMUM DESIGN WIND PRESSURE REQUIREMENT FOR VINYL SIDING
463 TABLE R703.15.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
464 TABLE R703.15.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
TABLE R703.16.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
465 TABLE R703.16.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
466 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 8 – ROOF-CEILING CONSTRUCTION
468 CHAPTER 8 ROOF-CEILING CONSTRUCTION
SECTION R801 GENERAL
SECTION R802 WOOD ROOF FRAMING
470 TABLE R802.4.1(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
471 TABLE R802.4.1(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
472 TABLE R802.4.1(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
473 TABLE R802.4.1(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
474 TABLE R802.4.1(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
475 TABLE R802.4.1(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
476 TABLE R802.4.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
477 TABLE R802.4.1(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
478 TABLE R802.4.1(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
479 TABLE R802.4.1(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
480 TABLE R802.4.1(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
481 TABLE R802.4.1(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
482 TABLE R802.4.1(7) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
483 TABLE R802.4.1(7)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling not attached to rafters, L/Δ = 180)
484 TABLE R802.4.1(8) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
485 TABLE R802.4.1(8)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 70 psf, ceiling attached to rafters, L/Δ = 240)
486 FIGURE R802.4.5 BRACED RAFTER CONSTRUCTION
487 TABLE R802.5.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
488 TABLE R802.5.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
489 TABLE R802.5.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
490 TABLE R802.5.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
491 TABLE R802.5.2 RAFTER/CEILING JOIST HEEL JOINT CONNECTIONS
492 FIGURE R802.7.1.1 RAFTER NOTCH
493 FIGURE R802.7.1.2 CEILING JOIST TAPER CUT
494 SECTION R803 ROOF SHEATHING
TABLE R803.1 MINIMUM THICKNESS OF LUMBER ROOF SHEATHING
495 TABLE R802.11 RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION)
496 TABLE R802.11—continued RAFTER OR TRUSS UPLIFT CONNECTION FORCES FROM WIND (ASD) (POUNDS PER CONNECTION
497 SECTION R804 COLD-FORMED STEEL ROOF FRAMING
FIGURE R804.1.2 IN-LINE FRAMING
498 TABLE R804.2.3 LOAD-BEARING COLD-FORMED STEEL ROOF FRAMING MEMBER SIZES AND THICKNESSES
FIGURE R804.2.3(1) C-SHAPED SECTION
FIGURE R804.2.3(2) TRACK SECTION
499 FIGURE R804.2.6.1 ROOF FRAMING MEMBER WEB HOLES
500 FIGURE R804.2.6.3 ROOF FRAMING MEMBER WEB HOLE PATCH
501 FIGURE R804.3 COLD-FORMED STEEL ROOF CONSTRUCTION
TABLE R804.3 ROOF FRAMING FASTENING SCHEDULE
502 TABLE R804.3.1.1(1) CEILING JOIST SPANS 10 PSF LIVE LOAD (NO ATTIC STORAGE)
503 TABLE R804.3.1.1(2) CEILING JOIST SPANS 20 PSF LIVE LOAD (LIMITED ATTIC STORAGE)
TABLE R804.3.1.1(3) NUMBER OF SCREWS REQUIRED FOR CEILING JOIST TO ROOF RAFTER CONNECTIONa
504 FIGURE R804.3.1.1 JOIST TO RAFTER CONNECTION
FIGURE R804.3.1.3(1) CEILING JOIST TOP FLANGE BRACING WITH C-SHAPED, TRACK OR COLD-ROLLED CHANNEL
505 FIGURE R804.3.1.3(2) CEILING JOIST TOP FLANGE BRACING WITH CONTINUOUS STEEL STRAP AND BLOCKING
FIGURE R804.3.1.4 SPLICED CEILING JOISTS
506 FIGURE R804.3.2.1.2 GABLE ENDWALL OVERHANG DETAILS
507 TABLE R804.3.2.1(1) ROOF RAFTER SPANS
TABLE R804.3.2.1(2) ULTIMATE DESIGN WIND SPEED TO EQUIVALENT SNOW LOAD CONVERSION
508 FIGURE R804.3.2.4 RIDGE MEMBER CONNECTION
TABLE R804.3.2.4 SCREWS REQUIRED AT EACH LEG OF CLIP ANGLE FOR ROOF RAFTER TO RIDGE MEMBER CONNECTION
509 FIGURE R804.3.5(1) ROOF OR CEILING OPENING
510 FIGURE R804.3.5(2) HEADER TO TRIMMER CONNECTION
TABLE R804.3.7.1 REQUIRED LENGTHS FOR CEILING DIAPHRAGMS AT GABLE ENDWALLS GYPSUM BOARD SHEATHED, CEILING HEIGHT = 8 FEET
511 FIGURE R804.3.7.1(1) CEILING DIAPHRAGM TO GABLE ENDWALL DETAIL
FIGURE R804.3.7.1(2) CEILING DIAPHRAGM TO SIDEWALL DETAIL
512 FIGURE R804.3.7.2 ROOF BLOCKING DETAIL
SECTION R805 CEILING FINISHES
SECTION R806 ROOF VENTILATION
514 TABLE R806.5 INSULATION FOR CONDENSATION CONTROL
SECTION R807 ATTIC ACCESS
516 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 9 – ROOF ASSEMBLIES
518 CHAPTER 9 ROOF ASSEMBLIES
SECTION R901 GENERAL
SECTION R902 FIRE CLASSIFICATION
519 SECTION R903 WEATHER PROTECTION
SECTION R904 MATERIALS
SECTION R905 REQUIREMENTS FOR ROOF COVERINGS
520 TABLE R905.1.1(1) UNDERLAYMENT TYPES
521 TABLE R905.1.1(2) UNDERLAYMENT APPLICATION
522 TABLE R905.1.1(2)—continued UNDERLAYMENT APPLICATION
TABLE R905.1.1(3) UNDERLAYMENT ATTACHMENT
523 TABLE R905.2.4.1 CLASSIFICATION OF ASPHALT ROOF SHINGLES
524 TABLE R905.2.8.2 VALLEY LINING MATERIAL
525 TABLE R905.3.7 CLAY AND CONCRETE TILE ATTACHMENT
526 TABLE R905.6.5 SLATE SHINGLE HEADLAP
TABLE R905.7.4 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE R905.7.5(1) WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
527 TABLE R905.7.5(2) NAIL REQUIREMENTS FOR WOOD SHAKES AND WOOD SHINGLES
TABLE R905.8.5 WOOD SHAKE MATERIAL REQUIREMENTS
528 TABLE R905.8.6 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
TABLE R905.10.3(2) MINIMUM CORROSION RESISTANCE
529 TABLE R905.9.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE R905.10.3(1) METAL ROOF COVERING STANDARDS
530 TABLE R905.11.2 MODIFIED BITUMEN ROOFING MATERIAL STANDARDS
TABLE R905.14.3 PROTECTIVE COATING MATERIAL STANDARDS
531 SECTION R906 ROOF INSULATION
TABLE R906.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION R907 ROOFTOP-MOUNTED PHOTOVOLTAIC PANEL SYSTEMS
SECTION R908 REROOFING
532 SECTION R918 SOLAR PHOTOVOLTAIC PANELS/MODULES
534 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 10 – CHIMNEYS AND FIREPLACES
536 CHAPTER 10 CHIMNEYS AND FIREPLACES
SECTION R1001 MASONRY FIREPLACES
537 TABLE R1001.1 SUMMARY OF REQUIREMENTS FOR MASONRY FIREPLACES AND CHIMNEYS
538 FIGURE R1001.1 FIREPLACE AND CHIMNEY DETAILS
539 FIGURE R1001.11 CLEARANCE FROM COMBUSTIBLES
540 SECTION R1002 MASONRY HEATERS
SECTION R1003 MASONRY CHIMNEYS
542 TABLE R1003.14(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE R1003.14(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
543 FIGURE R1003.15.2 FLUE SIZES FOR MASONRY CHIMNEYS
544 TABLE R1003.20 CRICKET DIMENSIONS
FIGURE R1003.18 CLEARANCE FROM COMBUSTIBLES
SECTION R1004 FACTORY-BUILT FIREPLACES
545 FIGURE R1003.20 CHIMNEY CRICKET
SECTION R1005 FACTORY-BUILT CHIMNEYS
546 SECTION R1006 EXTERIOR AIR SUPPLY
548 PART IV—ENERGY CONSERVATION
550 PART V—MECHANICAL
552 PART VI—FUEL GAS
554 PART VII—PLUMBING
556 PART VIII—ELECTRICAL
558 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE CHAPTER 44 – REFERENCED STANDARDS
560 PART IX—REFERENCED STANDARDS
CHAPTER 44 REFERENCED STANDARDS
AAMA
ACCA
ACI
561 AISI
ANSI
APA
562 ASCE/SEI
ASSE
ASTM
571 AWC
AWPA
CEN
572 CPA
CPSC
CSA
CSSB
DASMA
573 DOC
FEMA
FM
GA
HPVA
ICC
574 ISO
NFPA
577 PCA
SBCA
SFM
TMS
578 TPI
UBC
UL
579 ULC
WDMA
WMA
580 APPENDIX A RESERVED
582 APPENDIX B RESERVED
584 APPENDIX C RESERVED
586 APPENDIX D RESERVED
588 APPENDIX E RESERVED
590 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX F – RADON CONTROL METHODS
APPENDIX F RADON CONTROL METHODS
SECTION AF101 SCOPE
SECTION AF102 DEFINITIONS
591 SECTION AF103 REQUIREMENTS
593 FIGURE AF101 EPA MAP OF RADON ZONES
594 TABLE AF101(1) HIGH RADON-POTENTIAL (ZONE 1) COUNTIES
595 TABLE AF101(1)—continued HIGH RADON-POTENTIAL (ZONE 1) COUNTIES
596 FIGURE AF103 RADON-RESISTANT CONSTRUCTION DETAILS FOR FOUR FOUNDATION TYPES
598 APPENDIX G RESERVED
600 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX H – PATIO COVERS
APPENDIX H PATIO COVERS
SECTION AH101 GENERAL
SECTION AH102 DEFINITION
SECTION AH103 EXTERIOR WALLS AND OPENINGS
SECTION AH104 HEIGHT
601 SECTION AH105 STRUCTURAL PROVISIONS
SECTION AH106 SPECIAL PROVISIONS FOR ALUMINUM SCREEN ENCLOSURES IN HURRICANE-PRONE REGIONS
TABLE AH106.4(1) DESIGN WIND PRESSURES FOR SCREEN ENCLOSURE FRAMING
602 TABLE AH106.4(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE
603 FIGURE AH106.4.1 ULTIMATE DESIGN WIND SPEEDS FOR PATIO COVERS AND SCREEN ENCLOSURES
604 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX I – PRIVATE SEWAGE DISPOSAL
APPENDIX I PRIVATE SEWAGE DISPOSAL
SECTION AI101 GENERAL
606 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX J – EXISTING BUILDINGS AND STRUCTURES
APPENDIX J EXISTING BUILDINGS AND STRUCTURES
SECTION AJ101 PURPOSE AND INTENT
SECTION AJ102 COMPLIANCE
607 SECTION AJ103 PRELIMINARY MEETING
SECTION AJ104 EVALUATION OF AN EXISTING BUILDING
608 SECTION AJ105 PERMIT
SECTION AJ201 DEFINITIONS
SECTION AJ301 REPAIRS
609 SECTION AJ401 RENOVATIONS
SECTION AJ501 ALTERATIONS
610 SECTION AJ601 RECONSTRUCTION
SECTION AJ701 REFERENCED STANDARDS
612 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX K – SOUND TRANSMISSION
APPENDIX K SOUND TRANSMISSION
SECTION AK101 GENERAL
SECTION AK102 AIRBORNE SOUND
SECTION AK103 STRUCTURAL-BORNE SOUND
SECTION AK104 REFERENCED STANDARDS
614 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX L – PERMIT FEES
APPENDIX L PERMIT FEES
616 APPENDIX M RESERVED
618 APPENDIX N RESERVED
620 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX O – AUTOMATIC VEHICULAR GATES
APPENDIX O AUTOMATIC VEHICULAR GATES
SECTION AO101 GENERAL
SECTION AO102 DEFINITION
SECTION AO103 AUTOMATIC VEHICULAR GATES
SECTION AO104 REFERENCED STANDARDS
622 APPENDIX P RESERVED
624 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX Q – TINY HOUSES
APPENDIX Q TINY HOUSES
SECTION AQ101 GENERAL
SECTION AQ102 DEFINITIONS
SECTION AQ103 CEILING HEIGHT
SECTION AQ104 LOFTS
625 SECTION AQ105 EMERGENCY ESCAPE AND RESCUE OPENINGS
626 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX R – LIGHT STRAW-CLAY CONSTRUCTION
APPENDIX R LIGHT STRAW-CLAY CONSTRUCTION
SECTION AR101 GENERAL
SECTION AR102 DEFINITIONS
SECTION AR103 NONBEARING LIGHT STRAW-CLAY CONSTRUCTION
627 TABLE AR103.2.3 REQUIREMENTS AND PROPERTIES OF LIGHT STRAW-CLAY MIXTURES
FIGURE AR103.2.4(1) LIGHT STRAW-CLAY WALL WITH LARSEN TRUSSES
FIGURE AR103.2.4(2) LIGHT STRAW-CLAY WALL SINGLE STUD WIDTH
628 FIGURE AR103.2.4(3) LIGHT STRAW-CLAY WALL WITH BLIND STUDS
629 SECTION AR104 THERMAL PERFORMANCE
630 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX S – STRAWBALE CONSTRUCTION
APPENDIX S STRAWBALE CONSTRUCTION
SECTION AS101 GENERAL
SECTION AS102 DEFINITIONS
631 FIGURE AS101.1 TYPICAL STRAWBALE WALL SYSTEMS
FIGURE AS102.1 BALE ORIENTATIONS
632 SECTION AS103 BALES
FIGURE AS103.2 APPROXIMATE DIMENSIONS OF COMMON STRAW BALES
633 SECTION AS104 FINISHES
634 FIGURE AS105.1(1) TYPICAL BASE OF PLASTERED STRAWBALE WALL ON CONCRETE SLAB AND FOOTING
635 FIGURE AS105.1(2) TYPICAL BASE OF PLASTERED STRAWBALE WALL OVER RAISED FLOOR
636 FIGURE AS105.1(3) TYPICAL TOP OF LOAD-BEARING STRAWBALE WALL
FIGURE AS105.1(4) TYPICAL TOP OF POST-AND-BEAM WALL WITH PLASTERED STRAWBALE INFILL
637 SECTION AS105 STRAWBALE WALLS—GENERAL
TABLE AS105.4 OUT-OF-PLANE RESISTANCE METHODS AND UNRESTRAINED WALL DIMENSION LIMITS
639 SECTION AS106 STRAWBALE WALLS—STRUCTURAL
TABLE AS106.6.1 MINIMUM COMPRESSIVE STRENGTH FOR PLASTERS ON STRUCTURAL WALLS
640 TABLE AS106.12 ALLOWABLE SUPERIMPOSED VERTICAL LOADS (LBS/FOOT) FOR PLASTERED LOAD-BEARING STRAWBALE WALLS
641 EQUATION AS-1
TABLE AS106.13(1) PLASTERED STRAWBALE BRACED WALL PANEL TYPES
642 TABLE AS106.13(2) BRACING REQUIREMENTS FOR STRAWBALE-BRACED WALL PANELS BASED ON WIND SPEED
643 TABLE AS106.13(3) BRACING REQUIREMENTS FOR STRAWBALE-BRACED WALL PANELS BASED ON SEISMIC DESIGN CATEGORY
644 SECTION AS107 FIRE RESISTANCE
SECTION AS108 THERMAL INSULATION
SECTION AS109 REFERENCED STANDARDS
646 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX T – SOLAR-READY PROVISIONS—DETACHED ONE- ANDTWO-FAMILY DWELLINGS AND TOWNHOUSES
APPENDIX T [RE] SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION T101 SCOPE
SECTION T102 (RA102) GENERAL DEFINITION
SECTION T103 (RA103) SOLAR-READY ZONE
648 APPENDIX U RESERVED
650 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX V – SWIMMING POOL SAFETY ACT
APPENDIX V SWIMMING POOL SAFETY ACT
AV100 PRIVATE SWIMMING POOLS (STATEWIDE)
AV100.1 DEFINITIONS
AV100.2 CONSTRUCTION PERMIT; SAFETY FEATURES REQUIRED
651 AV100.3 ENCLOSURE; REQUIRED CHARACTERISTICS
AV100.4 AGREEMENTS TO BUILD; NOTICE OF PROVISIONS
AV100.5 EXEMPT FACILITIES
AV100.6 APPLICATION TO FACILITIES REGULATED BY DEPARTMENT OF SOCIAL SERVICES
AV100.7 MODIFICATION AND INTERPRETATION OF DIVISION
652 AV100.8 CONSTRUCTION REQUIREMENTS FOR BUILDING A POOL OR SPA
AV100.9 INFORMATIVE DOCUMENTS
654 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX W – AREAS PROTECTED BY THE FACILITIESOF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
APPENDIX W AREAS PROTECTED BY THE FACILITIES OF THE CENTRAL VALLEY FLOOD PROTECTION PLAN
AW101 GENERAL
AW102 DEFINITIONS
655 AW103 STRUCTURAL STABILITY
AW104 EVACUATION LOCATIONS
AW105 SPACE WITHIN THE BUILDING
656 AW106 DECKS AND BALCONIES THAT ARE EVACUATION LOCATIONS
AW107 ROOFTOP EVACUATION LOCATIONS
AW108 ATTICS THAT ARE EVACUATION LOCATIONS
AW109 ALTERNATE MEANS OF PROTECTION
657 FIGURE K103.1
658 FIGURE K103.1
660 CALIFORNIA RESIDENTIAL CODE – MATRIX ADOPTION TABLE APPENDIX X – EMERGENCY HOUSING
APPENDIX X EMERGENCY HOUSING
SECTION AX101 GENERAL
SECTION AX102 DEFINITIONS
661 SECTION AX103 EMERGENCY HOUSING
SECTION AX104 EMERGENCY SLEEPING CABINS
662 SECTION AX105 EMERGENCY TRANSPORTABLE HOUSING UNITS
SECTION AX106 TENTS AND MEMBRANE STRUCTURES
SECTION AX107 ACCESSIBILITY
SECTION AX108 LOFTS IN EMERGENCY HOUSING
663 SECTION AX109 LOCATION, MAINTENANCE AND IDENTIFICATION
SECTION AX110 EMERGENCY HOUSING FACILITIES
666 INDEX
676 HISTORY NOTE APPENDIX
678 HELPFUL TOOLS FOR YOUR CALIFORNIA RESIDENTIAL CODE
679 ICC ASSESSMENT CENTER
CA ResidentialCode 2019
$78.00