Shopping Cart

No products in the cart.

CT StateBldgCode IBCPortion 2016

$61.67

2012 International Building Code Portion of the 2016 Connecticut State Building Code

Published By Publication Date Number of Pages
CT 2016 740
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

Fully integrated code based on the 2012 IBC

PDF Catalog

PDF Pages PDF Title
1 2012 INTERNATIONAL BUILDING CODE® PORTION OF THE 2016 CONNECTICUT STATE BUILDING CODE
2 2012 INTERNATIONAL BUILDING CODE® PORTION OF THE 2016 CONNECTICUT STATE BUILDING CODE TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
22 LEGISLATION
24 TABLE OF CONTENTS
32 CHAPTER 1 SCOPE AND ADMINISTRATION
SECTION 101 GENERAL
33 SECTION 102 APPLICABILITY
SECTION 103 ENFORCEMENT AGENCY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
35 SECTION 105 PERMITS
38 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
41 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
42 SECTION 111 CERTIFICATE OF OCCUPANCY
44 SECTION 112 SERVICE UTILITIES
SECTION 113 MEANS OF APPEAL
45 SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
46 SECTION 117 EMERGENCY MEASURES
SECTION 118 VACANT BUILDINGS
48 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
78 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 GENERAL
SECTION 302 CLASSIFICATION
SECTION 303 ASSEMBLY GROUP A
79 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
SECTION 306 FACTORY GROUP F
80 SECTION 307 HIGH-HAZARD GROUP H
82 [F] TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
83 [F] TABLE 307.1(1)—(continued) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa
84 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
85 SECTION 308 INSTITUTIONAL GROUP I
86 SECTION 309 MERCANTILE GROUP M
SECTION 310 RESIDENTIAL GROUP R
87 SECTION 311 STORAGE GROUP S
88 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
90 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
94 SECTION 403 HIGH-RISE BUILDINGS
95 TABLE 403.2.4 MINIMUM BOND STRENGTH
96 SECTION 404 ATRIUMS
97 SECTION 405 UNDERGROUND BUILDINGS
98 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
100 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
102 SECTION 407 GROUP I-2
105 SECTION 408 GROUP I-3
107 SECTION 409 MOTION PICTURE PROJECTION ROOMS
108 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
110 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
111 TABLE 412.3.1 HEIGHT AND AREA LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
112 TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
113 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
[F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
115 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NON FLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
116 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
117 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
119 [F] TABLE 415.5.2 DETACHED BUILDING REQUIRED
122 [F] TABLE 415.10.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
127 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
128 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3
129 SECTION 421 HYDROGEN CUTOFF ROOMS
SECTION 422 AMBULATORY CARE FACIILITIES
130 SECTION 423 STORM SHELTERS
SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 GROUP E
132 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
SECTION 504 BUILDING HEIGHT
133 TABLE 503 ALLOWABLE BUILDING HEIGHTS AND AREAS Building height limitations shown in feet above grade plane. Story limitations shown as stories above grade plane.
Building area limitations shown in square feet, as determined by the definition of “Area, building,” per story
134 TABLE 503—continued ALLOWABLE BUILDING HEIGHTS AND AREAS
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
135 SECTION 506 BUILDING AREA MODIFICATIONS
EQUATION 5-1
EQUATION 5-2
136 EQUATION 5-3
SECTION 507 UNLIMITED AREA BUILDINGS
138 SECTION 508 MIXED USE AND OCCUPANCY
139 SECTION 509 INCIDENTAL USES
140 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
SECTION 510 SPECIAL PROVISIONS
141 TABLE 509 INCIDENTAL USES
144 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
145 TABLE 602.4 WOOD MEMBER SIZE EQUIVALENCIES
TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, e, h
146 SECTION 603 COMBUSTIBLE MATERIAL IN TYPE I AND II CONSTRUCTION
148 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
149 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
151 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
152 EQUATION 7-1
FIGURE 705.7 EQUIVALENT OPENING FACTOR
153 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
154 EQUATION 7-2
155 SECTION 706 FIRE WALLS
TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
157 SECTION 707 FIRE BARRIERS
158 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
159 SECTION 708 FIRE PARTITIONS
160 SECTION 709 SMOKE BARRIERS
SECTION 710 SMOKE PARTITIONS
161 SECTION 711 HORIZONTAL ASSEMBLIES
162 SECTION 712 VERTICAL OPENINGS
163 SECTION 713 SHAFT ENCLOSURES
165 SECTION 714 PENETRATIONS
167 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
168 SECTION 716 OPENING PROTECTIVES
169 TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
170 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
171 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
174 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
175 TABLE 717.3.2.1 FIRE DAMPER RATING
178 SECTION 718 CONCEALED SPACES
181 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
182 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
183 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALS
184 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
185 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
186 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
187 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
188 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
189 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
190 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
191 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
192 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
193 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
194 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
195 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
196 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
197 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
198 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
199 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
200 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
201 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
202 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
203 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
204 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
205 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMS
SECTION 722 CALCULATED FIRE RESISTANCE
206 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
207 TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
208 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
209 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
210 FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
211 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
212 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
213 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
EQUATION 7-6
214 EQUATION 7-7
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLS
215 TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
216 EQUATION 7-8
EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
217 EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
218 FIGURE 722.5.1(2) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
EQUATION 7-13
FIGURE 722.5.1(3) GYPSUM WALLBOARD PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
219 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
EQUATION 7-14
EQUATION 7-15
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURE STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
220 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNS
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
221 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
222 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
223 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
224 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
225 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
226 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
227 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
228 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
229 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
230 EQUATION 7-16
FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
231 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANES
232 TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
233 EQUATION 7-18
EQUATION 7-19
EQUATION 7-20
EQUATION 7-21
FIGURE 722.6.3(1) LOAD FIGURE
FIGURE 722.6.3(2) EFFECTIVE LENGTH FACTORS
234 CHAPTER 8 INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
236 TABLE 803.9 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
237 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
238 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
240 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
241 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
243 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
245 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
247 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
249 SECTION 905 STANDPIPE SYSTEMS
251 SECTION 906 PORTABLE FIRE EXTINGUISHERS
252 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
260 [F] TABLE 907.5.2.3.3 VISIBLE ALARMS
261 SECTION 908 EMERGENCY ALARM SYSTEMS
262 SECTION 909 SMOKE CONTROL SYSTEMS
264 EQUATION 9-1
EQUATION 9-2
EQUATION 9-3
270 SECTION 910 SMOKE AND HEAT REMOVAL
271 [F] TABLE 910.3 REQUIREMENTS FOR DRAFT CURTAINS AND SMOKE AND HEAT VENTSa
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
272 SECTION 912 FIRE DEPARTMENT CONNECTIONS
273 SECTION 913 FIRE PUMPS
SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
274 SECTION 915 CARBON MONOXIDE DETECTION
276 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS
277 SECTION 1004 OCCUPANT LOAD
278 TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
279 SECTION 1005 MEANS OF EGRESS SIZING
SECTION 1006 MEANS OF EGRESS ILLUMINATION
280 SECTION 1007 ACCESSIBLE MEANS OF EGRESS
282 SECTION 1008 DOORS, GATES AND TURNSTILES
284 TABLE 1008.1.4.1 REVOLVING DOOR SPEEDS
289 SECTION 1009 STAIRWAYS
293 SECTION 1010 RAMPS
294 SECTION 1011 EXIT SIGNS
295 SECTION 1012 HANDRAILS
296 SECTION 1013 GUARDS
298 SECTION 1014 EXIT ACCESS
TABLE 1014.3 COMMON PATH OF EGRESS TRAVEL
299 SECTION 1015 EXIT AND EXIT ACCESS DOORWAYS
TABLE 1015.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
300 SECTION 1016 EXIT ACCESS TRAVEL DISTANCE
TABLE 1016.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1017 AISLES
301 SECTION 1018 CORRIDORS
TABLE 1018.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1018.2 MINIMUM CORRIDOR WIDTH
302 SECTION 1019 EGRESS BALCONIES
SECTION 1020 EXITS
SECTION 1021 NUMBER OF EXITS AND EXIT CONFIGURATION
304 TABLE 1021.2(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1021.2(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1022 INTERIOR EXIT STAIRWAYS AND RAMPS
306 SECTION 1023 EXIT PASSAGEWAYS
SECTION 1024 LUMINOUS EGRESS PATH MARKINGS
308 SECTION 1025 HORIZONTAL EXITS
309 SECTION 1026 EXTERIOR EXIT STAIRWAYS AND RAMPS
310 SECTION 1027 EXIT DISCHARGE
311 SECTION 1028 ASSEMBLY
312 TABLE 1028.6.2 WIDTH OF AISLES FOR SMOKE-PROTECTED ASSEMBLY
314 TABLE 1028.10.2.1 SMOKE-PROTECTED ASSEMBLY AISLE ACCESSWAYS
316 SECTION 1029 EMERGENCY ESCAPE AND RESCUE
318 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
319 SECTION 1104 ACCESSIBLE ROUTE
320 SECTION 1105 ACCESSIBLE ENTRANCES
321 SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
TABLE 1106.1 ACCESSIBLE PARKING SPACES
322 SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
323 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
325 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
326 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
327 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
328 SECTION 1109 OTHER FEATURES AND FACILITIES
330 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
331 SECTION 1110 SIGNAGE
334 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
335 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
336 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
337 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
340 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
342 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
343 SECTION 1404 MATERIALS
SECTION 1405 INSTALLATION OF WALL COVERINGS
344 TABLE 1405.3.1 CLASS III VAPOR RETARDERS
TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
348 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
349 TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
351 TABLE 1407.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
352 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
354 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
SECTION 1503 WEATHER PROTECTION
355 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
356 TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
357 TABLE 1507.2.7.1(1) CLASSIFICATION OF ASPHALT ROOF SHINGLES PER ASTM D7158a
TABLE 1507.2.7.1(2) CLASSIFICATION OF ASPHALT SHINGLES PER ASTM D3161
358 TABLE 1507.2.9.2 VALLEY LINING MATERIAL
360 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENT
361 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
363 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
364 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
365 TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
366 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
367 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
368 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 ROOFTOP STRUCTURES
371 SECTION 1510 REROOFING
SECTION 1511 SOLAR PHOTOVOLTAIC PANELS/MODULES
372 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
373 SECTION 1604 GENERAL DESIGN REQUIREMENTS
374 TABLE 1604.3 DEFLECTION LIMITS
375 SECTION 1605 LOAD COMBINATIONS
376 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
377 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
378 EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
379 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
380 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
381 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
EQUATION 16-23
382 TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16-24
EQUATION 16-25
383 EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
384 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg , FOR ALASKAN LOCATIONS
385 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
386 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
387 SECTION 1609 WIND LOADS
388 TABLE 1609.1.2 WIND-BORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONSa, b, c
389 FIGURE 1609A ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
390 FIGURE 1609B ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY III AND IV BUILDINGS AND OTHER STRUCTURES
391 FIGURE 1609C ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
392 EQUATION 16-34
393 EQUATION 16-35
394 TABLE 1609.6.2 NET PRESSURE COEFFICIENTS, Cneta, b
395 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b
396 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cneta, b
397 TABLE 1609.6.2—continued NET PRESSURE COEFFICIENTS, Cnet a, b
SECTION 1610 SOIL LATERAL LOADS
398 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
EQUATION 16-36
399 [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
400 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
401 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
402 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
403 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
404 SECTION 1612 FLOOD LOADS
405 SECTION 1613 EARTHQUAKE LOADS
EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
EQUATION 16-40
TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa a
406 TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT FV a
TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
407 FIGURE 1613.3.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
408 FIGURE 1613.3.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
409 FIGURE 1613.3.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
410 FIGURE 1613.3.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
411 FIGURE 1613.3.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
412 FIGURE 1613.3.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
413 FIGURE 1613.3.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
414 FIGURE 1613.3.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
415 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 STRUCTURAL INTEGRITY
416 EQUATION 16-41
EQUATION 16-42
417 FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
418 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
419 SECTION 1704 SPECIAL INSPECTIONS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATIONS
421 SECTION 1705 REQUIRED VERIFICATION AND INSPECTION
422 TABLE 1705.2.2 REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL
423 TABLE 1705.3 REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
424 TABLE 1705.6 REQUIRED VERIFICATION AND INSPECTION OF SOILS
425 TABLE 1705.7 REQUIRED VERIFICATION AND INSPECTION OF DRIVEN DEEP FOUNDATION ELEMENTS
426 TABLE 1705.8 REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
429 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 TEST SAFE LOAD
SECTION 1709 IN-SITU LOAD TESTS
430 SECTION 1710 PRECONSTRUCTION LOAD TESTS
431 SECTION 1711 MATERIAL AND TEST STANDARDS
432 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
434 SECTION 1804 EXCAVATION, GRADING AND FILL
435 SECTION 1805 DAMPPROOFING AND WATERPROOFING
436 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
437 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
438 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
439 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
440 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
441 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES a, b, c
442 EQUATION 18-1
TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c
443 EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
444 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
445 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ′C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
446 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa, b, c, d
447 SECTION 1810 DEEP FOUNDATIONS
450 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
451 EQUATION 18-4
454 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
EQUATION 18-9
EQUATION 18-10
455 EQUATION 18-11
460 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
461 TABLE 1904.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f ′c)
FIGURE 1904.2 WEATHERING PROBABILITY MAP FOR CONCRETEa, b, c
462 SECTION 1905 MODIFICATIONS TO ACI 318
465 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
SECTION 1908 ANCHORAGE TO CONCRETE—ALLOWABLE STRESS DESIGN
EQUATION 19-1
SECTION 1909 ANCHORAGE TO CONCRETE—STRENGTH DESIGN
466 TABLE 1908.2 ALLOWABLE SERVICE LOAD ON EMBEDDED BOLTS (pounds)
SECTION 1910 SHOTCRETE
467 SECTION 1911 REINFORCED GYPSUM CONCRETE
SECTION 1912 CONCRETE-FILLED PIPE COLUMNS
470 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
472 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
474 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.11 CERAMIC TILE MORTAR COMPOSITIONS
475 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
476 TABLE 2105.2.2.1.1 COMPRESSIVE STRENGTH OF CLAY MASONRY
TABLE 2105.2.2.1.2 COMPRESSIVE STRENGTH OF CONCRETE MASONRY
477 SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF MASONRY
478 TABLE 2109.2.1 ALLOWABLE STRESS GROSS CROSS-SECTIONAL AREA FOR DRY-STACKED, SURFACE-BONDED CONCRETE MASONRY WALLS
EQUATION 21-2
479 TABLE 2109.3.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
SECTION 2110 GLASS UNIT MASONRY
480 SECTION 2111 MASONRY FIREPLACES
481 FIGURE 2111.11 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
482 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
485 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
486 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
487 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
488 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
489 SECTION 2207 STEEL JOISTS
SECTION 2208 STEEL CABLE STRUCTURES
490 SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
492 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
496 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
497 TABLE 2304.6 MINIMUM THICKNESS OF WALL SHEATHING
TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
498 TABLE 2304.7(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
TABLE 2304.7(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
499 TABLE 2304.7(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
TABLE 2304.7(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR) (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
500 TABLE 2304.7(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)a, b
502 TABLE 2304.9.1 FASTENING SCHEDULE
503 TABLE 2304.9.1—continued FASTENING SCHEDULE
504 TABLE 2304.9.1—continued FASTENING SCHEDULE
506 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2 (1)en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)
EQUATION 23-2
507 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
509 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
510 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
511 TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
512 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, g, h
513 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
514 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
515 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
518 TABLE 2308.8(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/Δ = 360)
519 TABLE 2308.8(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Sleeping Areas, Live Load = 30 psf, L/Δ = 360)
520 TABLE 2308.8(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/Δ = 360)
521 TABLE 2308.8(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential Living Areas, Live Load = 40 psf, L/Δ = 360)
522 TABLE 2308.9.1 SIZE, HEIGHT AND SPACING OF WOOD STUDS
523 FIGURE 2308.9.3 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
524 TABLE 2308.9.3(1) BRACED WALL PANELSa
TABLE 2308.9.3(2) EXPOSED PLYWOOD PANEL SIDING
TABLE 2308.9.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not Exposed to the Weather, Strength Axis Parallel or Perpendicular to Studs Except as Indicated Below)
525 TABLE 2308.9.3(4) ALLOWABLE SPANS FOR PARTICLE BOARD WALL SHEATHING (Not Exposed to the Weather, Long Dimension of the Panel Parallel or Perpendicular to Studs)
TABLE 2308.9.3(5) HARDBOARD SIDING
527 FIGURE 2308.9.3.2 ALTERNATE BRACED WALL PANEL ADJACENT TO A DOOR OR WINDOW OPENING
528 TABLE 2308.9.5 HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
529 TABLE 2308.9.5—continued HEADER AND GIRDER SPANSa FOR EXTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
530 TABLE 2308.9.6 HEADER AND GIRDER SPANSa FOR INTERIOR BEARING WALLS (Maximum Spans for Douglas Fir-Larch, Hem-Fir, Southern Pine and Spruce-Pine-Firb and Required Number of Jack Studs)
531 TABLE 2308.10.1 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS
532 TABLE 2308.10.2(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240)
533 TABLE 2308.10.2(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics Without Storage, Live Load = 10 pounds psf, L/Δ = 240)
534 TABLE 2308.10.2(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
535 TABLE 2308.10.2(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable Attics With Limited Storage, Live Load = 20 pounds per square foot, L/Δ = 240)
536 TABLE 2308.10.3(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
537 TABLE 2308.10.3(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
538 TABLE 2308.10.3(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
539 TABLE 2308.10.3(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof Live Load = 20 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
540 TABLE 2308.10.3(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
541 TABLE 2308.10.3(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
542 TABLE 2308.10.3(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
543 TABLE 2308.10.3(4)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Not Attached to Rafters, L/Δ = 180)
544 TABLE 2308.10.3(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
545 TABLE 2308.10.3(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 30 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
546 TABLE 2308.10.3(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
547 TABLE 2308.10.3(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground Snow Load = 50 pounds per square foot, Ceiling Attached to Rafters, L/Δ = 240)
548 TABLE 2308.10.4.1 RAFTER TIE CONNECTIONSg
550 TABLE 2308.10.9 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
551 TABLE 2308.10.9—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
552 FIGURE 2308.11.3.2 STEPPED FOOTING CONNECTION DETAILS
FIGURE 2308.11.3.3 OPENINGS IN HORIZONTAL DIAPHRAGMS
553 TABLE 2308.12.4 WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E (Minimum Percentage of Wall Bracing per each Braced Wall Linea)
555 FIGURE 2308.12.6(2) BRACED WALL PANELS SUPPORTED BY CANTILEVER OR SET BACK
FIGURE 2308.12.6(3) FLOOR OR ROOF NOT SUPPORTED ON ALL EDGES
556 FIGURE 2308.12.6(4) ROOF OR FLOOR EXTENSION BEYOND BRACED WALL LINE
FIGURE 2308.12.6(5) BRACED WALL PANEL EXTENSION OVER OPENING
FIGURE 2308.12.6(6) PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
557 FIGURE 2308.12.6(7) BRACED WALL LINES NOT PERPENDICULAR
FIGURE 2308.12.6(8) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
558 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
559 EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
561 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
SECTION 2406 SAFETY GLAZING
562 TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
563 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
564 SECTION 2409 GLASS IN ELEVATOR HOISTWAYS AND ELEVATOR CARS
566 CHAPTER 25 GYPSUM BOARD AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD MATERIALS
567 TABLE 2506.2 GYPSUM BOARD MATERIALS AND ACCESSORIES
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
568 TABLE 2508.5 SHEAR CAPACITY FOR HORIZONTAL WOOD FRAMED GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 GYPSUM BOARD IN SHOWERS AND WATER CLOSETS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
569 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
570 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
572 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
575 FIGURE 2603.9 TERMITE INFESTATION PROBABILITY MAP
SECTION 2604 INTERIOR FINISH AND TRIM
576 SECTION 2605 PLASTIC VENEER
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
577 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
578 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELS
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
579 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
580 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 FIBER-REINFORCED POLYMER
581 SECTION 2613 REFLECTIVE PLASTIC CORE INSULATION
582 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
584 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
586 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
[P] TABLE 2902.1
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
(See Sections 2902.1.1 and 2902.2)
587 [P] TABLE 2902.1—(continued)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
(See Sections 2902.1.1 and 2902.2)
588 [P] TABLE 2902.1—(continued)
MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa
(See Sections 2902.1.1 and 2902.2)
590 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
SECTION 3002 HOISTWAY ENCLOSURES
SECTION 3003 EMERGENCY OPERATIONS
591 SECTION 3004 HOISTWAY VENTING
SECTION 3005 CONVEYING SYSTEMS
592 SECTION 3006 MACHINE ROOMS
SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
593 FIGURE 3007.7.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
594 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
596 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
597 SECTION 3103 TEMPORARY STRUCTURES
599 TABLE 3103.12.2 MINIMUM NUMBER OF MEANS OF EGRESS AND MEANS OF EGRESS WIDTHS FROM TEMPORARY MEMBRANE STRUCTURES AND TENTS
600 SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
601 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
602 SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
SECTION 3109 SWIMMING POOL ENCLOSURES AND SAFETY DEVICES
604 SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR PHOTOVOLTAIC PANELS/MODULES
606 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
608 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
609 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
610 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
611 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
612 CHAPTER 34 EXISTING BUILDINGS AND STRUCTURES
SECTION 3401 GENERAL
SECTION 3402 DEFINITIONS
SECTION 3403 ADDITIONS
613 SECTION 3404 ALTERATIONS
614 SECTION 3405 REPAIRS
615 SECTION 3406 FIRE ESCAPES
SECTION 3407 GLASS REPLACEMENT
SECTION 3408 CHANGE OF OCCUPANCY
616 SECTION 3409 HISTORIC BUILDINGS
SECTION 3410 MOVED STRUCTURES
SECTION 3411 ACCESSIBILITY FOR EXISTING BUILDINGS
618 TABLE 3411.8.5 RAMPS
619 SECTION 3412 COMPLIANCE ALTERNATIVES
620 EQUATION 34-1
EQUATION 34-2
EQUATION 34-3
EQUATION 34-4
621 TABLE 3412.6.3 COMPARTMENTATION VALUES
TABLE 3412.6.4 SEPARATION VALUES
TABLE 3412.6.5 CORRIDOR WALL VALUES
622 TABLE 3412.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 3412.6.6(2) CONSTRUCTION-TYPE FACTOR
EQUATION 34-5
TABLE 3412.6.8 AUTOMATIC FIRE DETECTION VALUES
623 TABLE 3412.6.9 FIRE ALARM SYSTEM VALUES
TABLE 3412.6.10 SMOKE CONTROL VALUES
624 TABLE 3412.6.11 MEANS OF EGRESS VALUES
TABLE 3412.6.12 DEAD-END VALUES
EQUATION 34-6
TABLE 3412.6.14 ELEVATOR CONTROL VALUES
625 TABLE 3412.6.15 MEANS OF EGRESS EMERGENCY LIGHTING VALUES
TABLE 3412.6.16 MIXED OCCUPANCY VALUESa
TABLE 3412.6.17 SPRINKLER SYSTEM VALUES
626 TABLE 3412.6.18 STANDPIPE SYSTEM VALUES
TABLE 3412.6.19 INCIDENTAL USE AREA VALUES
627 TABLE 3412.7 SUMMARY SHEET—BUILDING CODE
628 TABLE 3412.8 MANDATORY SAFETY SCORESa
TABLE 3412.9 EVALUATION FORMULASa
630 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
631 AF&PA
AISC
AISI
632 AITC
ALI
AMCA
ANSI
633 APA
APSP
634 ASABE
ASCE/SEI
ASME
635 ASTM
641 AWCI
AWPA
AWS
BHMA
CGSB
642 CPA
CPSC
CSA
CSSB
DASMA
643 DOC
DOJ
DOL
DOTn
644 EN
FEMA
FM
GA
HPVA
645 HUD
ICC
646 ISO
NAAMM
NCMA
NFPA
648 PCI
PTI
RMI
SDI
SJI
649 SPRI
TIA
TMS
TPI
650 UL
651 ULC
USC
WDMA
WRI
652 APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
SECTION A102 REFERENCED STANDARDS
654 APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
656 APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
658 APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
659 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
660 SECTION D106 REFERENCED STANDARDS
662 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
TABLE E104.3.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
663 SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
664 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
665 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
666 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
668 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
670 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
671 SECTION G104 PERMITS
SECTION G105 VARIANCES
672 SECTION G201 DEFINITIONS
673 SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
SECTION G501 MANUFACTURED HOMES
674 SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
675 SECTION G1101 REFERENCED STANDARDS
676 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
677 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
678 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
679 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
680 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITIONS
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
682 APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
683 SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
684 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
685 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
686 APPENDIX K ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
687 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
688 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
690 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
692 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD
SECTION M101 TSUNAMI-GENERATED FLOOD HAZARD
SECTION M102 REFERENCED STANDARDS
694 APPENDIX N MUNICIPALITY—SPECIFIC STRUCTURAL DESIGN PARAMETERS
SPECIFIC STRUCTURAL DESIGN PARAMETERS
695 SPECIFIC STRUCTURAL DESIGN PARAMETERS—continued
696 SPECIFIC STRUCTURAL DESIGN PARAMETERS—continued
697 SPECIFIC STRUCTURAL DESIGN PARAMETERS—continued
698 SPECIFIC STRUCTURAL DESIGN PARAMETERS—continued
700 INDEX
738 GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED
739 BENEFITS THAT WORK FOR YOU
740 ICC EVALUATION SERVICE
CT StateBldgCode IBCPortion 2016
$61.67