FL Energy 07 2007
$12.32
Florida Building Code – Energy
Published By | Publication Date | Number of Pages |
FL | 2007 | 228 |
This Energy Code is Chapter 13 of the Florida Building Code
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | 2007 FLORIDA BUILDING CODE – CHAPTER 13: FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION |
3 | CHAPTER 13: ENERGY EFFICIENCY SUBCHAPTER 13-1 – ADMINISTRATION AND ENFORCEMENT SECTION 13-100: GENERAL SECTION 13-101: SCOPE |
6 | SECTION 13-102: MATERIAL AND EQUIPMENT SECTION 103: CODE COMPLIANCE AND PERMITTING |
7 | SECTION 13-104: INSPECTIONS |
8 | SECTION 13-105: REPORTING TABLE 13-105.1: REPORTING SCHEDULE SECTION 13-106: VALIDITY |
9 | FIGURE 1-1: CODE COMPLIANCE CHART |
11 | SUBCHAPTER 13-2 – DEFINITIONS SECTION 13-201 – GENERAL SECTION 13-202 – DEFINITIONS |
27 | SUBCHAPTER 13-3 – REFERENCED STANDARDS AND ORGANIZATIONS SECTION 13-301: REFERENCED STANDARDS AABC AAMA ACCA ADC |
28 | AHAM AMCA ANSI ARDM ARI |
29 | ASHRAE ASTM |
30 | CRRC CTI DASMA DOE |
31 | FLORIDA CODES FSEC FTC GAMA |
32 | HI HUD ISO NAIMA NEBB |
33 | NEMA NFPA NFRC SMACNA SRCC UL |
34 | WDMA |
35 | SUBCHAPTER 13-4 – COMMERCIAL BUILDING COMPLIANCE METHODS SECTION 13-400: ADMINISTRATION |
37 | TABLE 13-400.ABC.3: INDEX TO COMMERCIAL CODE COMPLIANCE FORMS SECTION 13-401: FENESTRATIONS (Glazing) |
38 | TABLE 13-401.C.3: SHGC Multipliers for Permanent Projections SECTION 13-402: WALLS SECTION 13-403: DOORS |
39 | SECTION 13-404: ROOFS/CEILINGS TABLE 13-404.C.1: ROOF U-FACTOR MULTIPLIERS FOR EXCEPTION TO 13-404.C.1 SECTION 13-405: FLOORS SECTION 13-406: AIR INFILTRATION |
40 | SECTION 13-407: SPACE COOLING SYSTEMS |
45 | SECTION 13-408: SPACE HEATING EQUIPMENT |
46 | TABLE 13-407.3.2.1A: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS. |
47 | TABLE 13-407.ABC.3.2.1B: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS |
48 | TABLE 13-407.ABC.3.2.1C – WATER CHILLING PACKAGES MINIMUM EFFICIENCY REQUIREMENTS |
49 | TABLE 13-407.ABC.3.2.1D – ELECTRICALLY-OPERATED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICLE AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOM AIR CONDITIONER HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS |
50 | TABLE 13-407.ABC.3.2.1G – PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT |
51 | TABLE 13-407.ABC.3.2.2H – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS <150 TONS COP = 5.00; IPLV = 5.25 |
52 | TABLE 13-407.ABC.3.2.2I – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS >150 TONS, <300 TONS COP = 5.55; IPLV = 5.90 |
53 | TABLE 13-407.ABC.3.2.2J – MINIMUM EFFICIENCIES FOR CENTRIFUGAL CHILLERS >300 TONS COP = 6.10; IPLV = 6.40 |
54 | TABLE 13-408.ABC.3.2.1E – WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS. MINIMUM EFFICIENCY REQUIREMENTS SECTION 13-409: VENTILATION |
55 | TABLE 13-408.ABC.3.2.1F – GAS- AND OIL-FIRED BOILERS MINIMUM EFFICIENCY REQUIREMENTS TABLE 13-409.ABC.3.3.1 – MAXIMUM DAMPER LEAKAGE |
56 | SECTION 13-410 – AIR DISTRIBUTION SYSTEMS TABLE 13-410.ABC.1.1.1 – FAN POWER LIMITATION |
57 | TABLE 13-410.ABC.2.2 – MINIMUM DUCT INSULATION R-VALUES Combined Heating and Cooling Supplu and Return Ducts |
62 | SECTION 13-411 – PUMPS AND PIPING |
63 | SECTION 13-412 – WATER HEATING SYSTEMS |
64 | TABLE 13-411.ABC.2 – MINIMUM PIPE INSULATION (inches) |
65 | SECTION 13-413 – ELECTRIC POWER SECTION 13-414 – MOTORS SECTION 13-415 – LIGHTING |
66 | TABLE 13-412.ABC.3 – PERFORMANCE REQUIREMENTS FOR WATER HEATING EQUIPMENT |
67 | TABLE 13-414.ABC.1 – MINIMUM NOMINAL EFFICIENCY FOR GENERAL PURPOSE Design A and Design B Motors |
69 | TABLE 13-415.ABC.2.2 – LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS |
71 | TABLE 13-415.B.1 – LIGHTING POWER DENSITIES (LPD) USING THE SPACE-BY-SPACE METHOD |
72 | TABLE 13-415.C.1 – LIGHTING POWER DENSITIES USING THE BUILDING AREA METHOD |
73 | SUBCHAPTER 13-6 – RESIDENTIAL BUILDING COMPLIANCE METHODS SECTION 13-600 – ADMINISTRATION |
75 | SECTION 13-601 – FENESTRATIONS (GLAZING) |
76 | SECTION 13-602 – WALLS |
77 | SECTION 13-603 – DOORS SECTION 13-604 – CEILINGS |
78 | SECTION 13-605 – FLOORS |
79 | FIGURE 13-604.A.3: ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS |
80 | SECTION 13-606 – AIR INFILTRATION TABLE 13-606.ABC.1.1 – ALLOWABLE AIR INFILTRATION RATES |
81 | SECTION 13-607 – SPACE COOLING SYSTEMS |
84 | TABLE 13-607.ABC.3.2A – ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITS – MINIMUM EFFICIENCY REQUIREMENTS |
85 | TABLE 13-607.ABC.3.2B – ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS |
86 | TABLE 13-607.ABC.3.2D – ELECTRICALLY OPERATRED PACKAGED TERMINAL AIR CONDITIONERS, PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS, SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS, AND ROOOM AIR CONDITIONERS HEAT PUMPS – MINIMUM EFFICIENCY REQUIREMENTS |
88 | SECTION 13-608 – SPACE HEATING SYSTEMS |
89 | TABLE 13-608.ABC.3.2E- WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS. MINIMUM EFFICIENCY REQUIREMENTS |
90 | TABLE 13-608.ABC.3.2FGAS- AND OIL-FIRED BOILERS MINIMUM EFFICIENCY REQUIREMENTS SECTION 13-609 – VENTILATION SYSTEMS |
91 | SECTION 13-610 – AIR DISTRIBUTION SYSTEMS TABLE 13-610.ABC.2.1 – MINIMUM INSULATION LEVELS AIR DISTRIBUTION SYSTEM COMPONENTS1 |
96 | SECTION 13-611 – PIPING TABLE 13-611.ABC.1 – MINIMUM PIPE INSULATION |
97 | SECTION 13-612 – WATER HEATING SYSTEMS |
98 | TABLE 13-612.ABC.3 – MINIMUM PERFORMANCE STANDARDS WATER HEATING EQUIPMENT: FIRED STORAGE WATER HEATER MINIMUM ENERGY FACTORS (EF) |
99 | SECTION 13-613 – CALCULATIONAL PARAMETERS SPECIFIC TO COMPLIANCE METHOD A TABLE 13-613.A.1-1 – SPECIFICATIONS FOR BASELINE AND AS-BUILT HOMES |
101 | TABLE 13-613.A.1-1(a) – DEFAULT BASELINE HOME HEATING AND COOLING EQUIPMENT EFFICIENCIES (i) (k) (m) (n) |
102 | TABLE 13-613.A.2-1 – COEFFICIENTS a and b |
103 | APPENDIX 13-A – JURISDICTIONAL DATA ALACHUA COUNTY BAKER COUNTY BAY COUNTY BRADFORD COUNTY BREVARD COUNTY |
104 | BROWARD COUNTY CALHOUN COUNTY CHARLOTTE COUNTY CITRUS COUNTY CLAY COUNTY |
105 | COLLIER COUNTY COLUMBIA COUNTY DESOTO COUNTY DIXIE COUNTY DUVAL COUNTY ESCAMBIA COUNTY FLAGLER COUNTY FRANKLIN COUNTY GADSDEN COUNTY |
106 | GILCHRIST COUNTY GLADES COUNTY GULF COUNTY HAMILTON COUNTY HARDEE COUNTY HENDRY COUNTY HERNANDO COUNTY HIGHLANDS COUNTY HILLSBOROUGH COUNTY HOLMES COUNTY INDIAN RIVER COUNTY |
107 | JACKSON COUNTY JEFFERSON COUNTY LAFAYETTE COUNTY LAKE COUNTY LEE COUNTY LEON COUNTY LEVY COUNTY LIBERTY COUNTY |
108 | MADISON COUNTY MANATEE COUNTY MARION COUNTY MARTIN COUNTY MIAMI-DADE COUNTY |
109 | MONROE COUNTY NASSAU COUNTY OKALOOSA COUNTY OKEECHOOBEE COUNTY ORANGE COUNTY |
110 | OSCEOLA COUNTY PALM BEACH COUNTY |
111 | PASCO COUNTY PINELLAS COUNTY |
112 | POLK COUNTY PUTNAM COUNTY ST JOHNS COUNTY ST LUCIE COUNTY SANTA ROSA COUNTY SARASOTA COUNTY SEMINOLE COUNTY |
113 | SEMINOLE INDIAN TRIBE SUMTER COUNTY SUWANNEE COUNTY TAYLOR COUNTY UNION COUNTY VOLUSIA COUNTY WAKULLA COUNTY WALTON COUNTY |
114 | WASHINGTON COUNTY |
115 | APPENDIX 13-B – SUPPLEMENTAL INFORMATION FOR SUBCHAPTER 13-4 B1.0 GENERAL REQUIREMENTS |
117 | B2.0 BUILDING ENVELOPE CHARACTERISTICS |
118 | TABLE B-1 – EMITTANCE VALUES OF VARIOUS SURFACES AND EFFECTIVE EMITTANCES OF AIR SPACES TABLE B-2 – R-VALUES FOR CAVITY AIR SPACES TABLE B-3 – EFFECTIVE R-VALUES FOR FIBERGLASS |
119 | TABLE B-4 – R-VALUES FOR BUILDING MATERIALS TABLE B-5 – THERMAL CONDUCTIVITY OF CONCRETE BLOCK MATERIAL |
120 | TABLE B-6 – ASSEMBLY U-FACTORS FOR UNLABELED SKYLIGHTS |
121 | TABLE B-7 – ASSEMBLY SOLAR HEAT GAIN COEFFICIENTS (SHGC) AND ASSEMBLY VISIBLE LIGHT TRANSMITTANCES (VLT)FOR UNLABELED SKYLIGHTS |
122 | TABLE B-8 – ASSEMBLY U-FACTORS, ASSEMBLY SOLAR HEAT GAIN COEFFICIENTS (SHGC), AND ASSEMBLY VISIBLE LIGHTTRANSMITTANCES (VLT) FOR UNLABELED VERTICAL FENESTRATION |
123 | TABLE B-9 – ASSEMBLY U-FACTORS FOR ABOVE-GRADE CONCRETE WALLS AND MASONRY WALLS |
125 | TABLE B-10 – ASSEMBLY U-FACTORS, C-FACTORS, Ru, Rc, AND HEAT CAPACITY FOR CONCRETE |
127 | TABLE B-11 – ASSEMBLY U-FACTORS, C-FACTORS, RU, RC, AND HEAT CAPACITY FOR CONCRETE BLOCK WALLS |
130 | TABLE B-12 – EFFECTIVE R-VALUES FOR INSULATION/FRAMING LAYERS ADDED TO ABOVE-GRADE MASS WALLS AND BELOW-GRADE WALLS |
131 | TABLE B-13 – ASSEMBLY U-FACTORS FOR METAL BUILDING WALLS TABLE B-14 – ASSEMBLY U-FACTORS FOR STEEL FRAME WALLS |
133 | TABLE B-15 – ASSEMBLY U-FACTORS FOR WOOD FRAME WALLS |
134 | TABLE B-16 – ASSEMBLY C-FACTORS FOR BELOW-GRADE WALLS TABLE B-17 – EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FORWALL INSULATION INSTALLED BETWEEN STEEL FRAMING |
135 | TABLE B-18 – EFFECTIVE INSULATION/FRAMING LAYER R-VALUES FOR ROOF AND FLOOR INSULATION INSTALLED BETWEEN METALFRAMING (4 FT ON CENTER) TABLE B-19 – ASSEMBLY U-FACTORS FOR ROOFS WITH INSULATION ENTIRELY ABOVE DECK |
137 | TABLE B-20 – ASSEMBLY U-FACTORS FOR METAL BUILDING ROOFS |
138 | TABLE B-21 – BASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH WOOD JOISTS TABLE B-22 – ASSEMBLY U-FACTORS FOR ATTIC ROOFS WITH STEEL JOISTS (4.0 FT ON CENTER) TABLE B-21A – Single Rafter Roofs |
140 | TABLE B-23 – ASSEMBLY U-FACTORS FOR MASS FLOORS |
141 | TABLE B-24 – ASSEMBLY U-FACTORS FOR STEEL JOIST FLOORS |
142 | TABLE B-25 – ASSEMBLY U-FACTORS FOR WOOD JOIST FLOORS |
143 | B3.1 CALCULATION PROCEDURES B4.1 LIGHTING CALCULATION PROCEDURES |
144 | TABLE B-26 – ASSEMBLY F-FACTORS FOR SLAB-ON-GRADE FLOORS |
145 | APPENDIX 13-C – SUPPLEMENTAL INFORMATION FOR SUBCHAPTER 13-6 13-C1.0 – GENERAL REQUIREMENTS TABLE 13-C1.2.2 – R-VALUES OF COMPRESSED INSULATION TABLE 13-C1.2.3 – INSULATION INSTALLATION STANDARDS 13-C2.0 GENERAL CRITERIA FOR THE BUILDING ENVELOPE |
146 | TABLE 13-C2.1.1 – DEFAULT WINDOW ENERGY VALUES FOR RESIDENTIAL APPLICATIONS 13-C3.0 -INFILTRATION AND INTERNAL GAINS |
147 | 13-C4.0 – HEATING, VENTILATING AND AIR CONDITIONING |
148 | TABLE 13-C4.1.1A – COOLING SYSTEM ASSUMED, MINIMUM RATINGS BY DATE PERMITTED AIR CONDITIONERS TABLE 13-C4.1.1B – HEATING SYSTEM ASSUMED, MINIMUM RATINGS BY DATE PERMITTED HEAT PUMPS |
149 | SUB-APPENDIX 13-2C – SUPPLEMENTAL CRITERIA FOR THE ALTERNATE RESIDENTIAL POINTS SYSTEM METHOD 13-2C1.0 – GENERAL REQUIREMENTS (EQUATION 13-2C1.2) 13-C2.0 – BUILDING ENVELOPE PERORMANCE CRITERIA (EQUATION 13-2C2.1.2A) (EQUATION 13-2C2.1.2B) (EQUATION 13-2C2.1.2C) (EQUATION 13-2C2.1.2D) |
150 | (EQUATION 13-2C2.1.2E) (EQUATION 13-2C2.1.2F) (EQUATION 13-2C2.1.2G) (EQUATION13-2C2.1.2H) FIGURE 6.1 |
151 | TABLE 13-2C2.1.1A – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 1, 2, 3 |
153 | TABLE 13-2C2.1.1B – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 4,5,6 |
155 | TABLE 13-2C2.1.1C – SUBSTITUTE GLASS POINT MULTIPLIERS BY GLASS SOLAR HEAT GAIN COEFFICIENTAND ORIENTATION FOR CLIMATE ZONES 7,8,9 |
157 | TABLE 13-2C2.2.2 – CONCRETE BLOCK MULTIPLIERS POLYSTYRENE BEAD AGGREGATE TABLE 13-2C2.4.1 – CEILING UNDER ATTIC SUMMER AND WINTER POINT MULTIPLIERS |
158 | TABLE 13-2C2.4.2 – CEILING SINGLE ASSEMBLY SUMMER AND WINTER POINT MULTIPLIERS TABLE 13-2C2.4.3 – CONCRETE DECK ROOF: EXPOSED SUMMER AND WINTER POINT MULTIPLIERS 13-2C3.0 – Infiltration and internal gains. 13-2C4.0 – Heating, ventilating and air conditioning. (Equation 13-2C4.1.1) |
159 | TABLE 13-2C2.4.4 – CONCRETE ROOF DECK: DROPPED SUMMER AND WINTER POINT MULTIPLIERS TABLE 13-2C2.5.1 – FLOORS MULTIPLIERS FOR STEM WALL WITH STEM WALL INSULATION TABLE 13-2C4.1.2A – COOLING SYSTEM MULTIPLIER ASSUMED MINIMUM RATINGS BY DATE PERMITTED AIR CONDITIONERS |
160 | TABLE 13-2C4.1.2B – HEATING SYSTEM MULTIPLIER ASSUMED MINIMUM RATINGS BY DATE PERMITTED HEAT PUMPS TABLE 13-2C4.2.1.1 – FAN SIZING TABLE TABLE 13-2C4.2 – COOLING SYSTEM MULTIPLIERS GAS FUELED AIR CONDITIONERS |
162 | FIGURE 13-2C4.2.1.4 – ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS |
163 | TABLE 13-2C4.3.1.3A – HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC SPACE GAS WATER HEATING WITH A STORAGE TANK TABLE 13-2C4.3.1.3B – HEATING SYSTEM CREDIT MULTIPLIERS FOR COMBINED HYDRONIC INSTANTANEOUS (TANKLESS) GAS WATER HEATING |
164 | TABLE 13-2C4.3.2.1 – HEATING SYSTEM MULTIPLIERS GAS FUELED HEAT PUMPS 13-2C5.0 – Air distribution systems. |
165 | TABLE 13-2C5.2.1A – DUCT MULTIPLIERS NORTH FLORIDA |
167 | TABLE 13-2C5.2.1B – DUCT MULTIPLIERS CENTRAL FLORIDA |
169 | TABLE 13-2C5.2.1C – DUCT MULTIPLIERS SOUTH FLORIDA |
171 | 13-2C6.0 – Service hot water. TABLE 13-2C6.2.1 – GAS INSTANTANEOUS (TANKLESS) WATER HEATER MULTIPLIERS |
173 | APPENDIX 13-D |
175 | Form 400C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION SUBCHAPTER 4 – Commercial Building Compliance Methods – ASHRAE CLIMATE ZONE 2 |
177 | Form 400C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTIONSUBCHAPTER 4 – Commercial Building Compliance Methods – ASHRAE CLIMATE ZONE 1 |
179 | FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION – Alternate Residential Points System Method – NORTH 1 2 3 |
180 | SUMMER CALCULATIONS CLIMATE ZONES 1 2 3 |
181 | SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 1 2 3 |
182 | WINTER CALCULATIONS CLIMATE ZONES 1 2 3 |
183 | WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 1 2 3 |
184 | ADDITIONAL TABLES CLIMATE ZONES 1 2 3 |
185 | FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Alternate Residential Points System Method CENTRAL 4 5 6 |
186 | SUMMER CALCULATIONS CLIMATE ZONES 4 5 6 |
187 | SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 4 5 6 |
188 | WINTER CALCULATIONS CLIMATE ZONES 4 5 6 |
189 | WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 4 5 6 |
190 | ADDITIONAL TABLES CLIMATE ZONES 4 5 6 |
191 | FORM 600A-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Alternate Residential Points System Method SOUTH 7 8 9 |
192 | SUMMER CALCULATIONS CLIMATE ZONES 7 8 9 |
193 | SUMMER POINT MULTIPLIERS (SPM) CLIMATE ZONES 7 8 9 |
194 | WINTER CALCULATIONS CLIMATE ZONES 7 8 9 |
195 | WINTER POINT MULTIPLIERS (WPM) CLIMATE ZONES 7 8 9 |
196 | ADDITIONAL TABLES CLIMATE ZONES 7 8 9 |
197 | FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B NORTH 1 2 3 |
198 | TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 1 2 3 |
199 | FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B CENTRAL 4 5 6 |
200 | TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 4 5 6 |
201 | FORM 1100B-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Component Prescriptive Method B SOUTH 7 8 9 |
202 | TABLE 11B-1 MINIMUM REQUIREMENTS Climate Zones 7 8 9 |
203 | FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C NORTH 1 2 3 |
205 | FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C CENTRAL 4 5 6 |
207 | FORM 1100C-07 – FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Residential Limited Applications Prescriptive Method C SOUTH 7 8 9 |
209 | FORM 1100D-07 – DESUPERHEATER, HEAT RECOVERY UNIT (HRU) WATER HEATER EFFICIENCY CERTIFICATION |
210 | ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD |
211 | APPENDIX 13-E – FLORIDA STANDARD NO. 1 (FL-1) FLORIDA REGULATORY MODIFICATIONS TO AIR-CONDITIONING & REFRIGERATION INSTITUTE (ARI) STANDARD 470-80 Effective April 1, 1986 SECTION 1 – PURPOSE SECTION 2 – SCOPE SECTION 3 – DEFINITIONS SECTION 4 – STANDARD EQUIPMENT AND ACCESSORIES SECTION 5 – TESTING AND RATING REQUIREMENTS |
212 | SECTION 7 – MARKING SECTION 8 – CONFORMANCE SECTION A2 – SCOPE SECTION A3 – DEFINITIONS SECTION A4 – EXPRESSION OF TEST RESULTS SECTION A5 – TEST METHODS |
213 | 2007 FLORIDA BUILDING CODE CHAPTER 1 BUILDING |
215 | CHAPTER 1 ADMINISTRATION SECTION 101 GENERAL SECTION 102 APPLICABILITY |
217 | SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED SECTION 104 DUTIES AND POWERS OF THE BUILDING OFFICIAL SECTION 105 PERMITS |
221 | SECTION 106 CONSTRUCTION DOCUMENTS |
224 | SECTION 107 TEMPORARY STRUCTURES AND USES SECTION 108 FEES |
225 | SECTION 109 INSPECTIONS |
227 | SECTION 110 CERTIFICATES OF OCCUPANCY AND COMPLETION |
228 | SECTION 111 SERVICE UTILITIES SECTION 112 BOARD OF APPEALS RESERVED SECTION 113 VIOLATIONS RESERVED SECTION 114 STOP WORK ORDER SECTION 115 UNSAFE STRUCTURES AND EQUIPMENT RESERVED |