PDF Pages PDF Title
1 FLORIDA BUILDING CODE 2010 EXISTING BUILDING
2 FLORIDA BUILDING CODE 2010 EXISTING BUILDING TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
10 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY RESERVED
11 SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED
SECTION 104 DUTIES AND POWERS OF CODE OFFICIAL RESERVED
SECTION 105 PERMITS RESERVED
SECTION 106 CONSTRUCTION DOCUMENTS RESERVED
SECTION 107 TEMPORARY STRUCTURES AND USES RESERVED
SECTION 108 FEES RESERVED
SECTION 109 INSPECTIONS RESERVED
SECTION 110 CERTIFICATE OF OCCUPANCY RESERVED
SECTION 111 SERVICE UTILITIES RESERVED
SECTION 112 BOARD OF APPEALS RESERVED
SECTION 113 VIOLATIONS RESERVED
SECTION 114 STOP WORK ORDER RESERVED
SECTION 115 UNSAFE BUILDINGS AND EQUIPMENT RESERVED
SECTION 116 EMERGENCY MEASURES RESERVED
SECTION 117 DEMOLITION RESERVED
12 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
16 CHAPTER 3 PRESCRIPTIVE COMPLIANCE METHOD
[B] SECTION 301 GENERAL
[B] SECTION 302 ADDITIONS
17 [B] SECTION 303 ALTERATIONS
[B] SECTION 304 REPAIRS
18 [B] SECTION 305 FIRE ESCAPES
19 [B] SECTION 306 GLASS REPLACEMENT
SECTION 307 CHANGE OF OCCUPANCY
[B] SECTION 308 HISTORIC BUILDINGS SEE CHAPTER 11
[B] SECTION 309 MOVED STRUCTURES
[B] SECTION 310 ACCESSIBILITY FOR EXISTING BUILDINGS
[B] SECTION 311 ENERGY CONSERVATION
SECTION 312 REROOFING
20 CHAPTER 4 CLASSIFICATION OF WORK
SECTION 401 GENERAL
SECTION 402 REPAIRS
SECTION 403 ALTERATION—LEVEL 1
SECTION 404 ALTERATION—LEVEL 2
SECTION 405 ALTERATION—LEVEL 3
SECTION 406 CHANGE OF OCCUPANCY
SECTION 407 ADDITIONS
SECTION 408 HISTORIC BUILDINGS
21 SECTION 409 RELOCATED BUILDINGS
SECTION 410 RETROFITTING
22 CHAPTER 5 REPAIRS
SECTION 501 GENERAL
SECTION 502 BUILDING ELEMENTS AND MATERIALS
SECTION 503 FIRE PROTECTION
SECTION 504 MEANS OF EGRESS
SECTION 505 ACCESSIBILITY
SECTION 506 STRUCTURAL
23 SECTION 507 ELECTRICAL
SECTION 508 MECHANICAL
24 SECTION 509 PLUMBING
26 CHAPTER 6 ALTERATIONS—LEVEL 1
SECTION 601 GENERAL
SECTION 602 BUILDING ELEMENTS AND MATERIALS
SECTION 603 FIRE PROTECTION
SECTION 604 MEANS OF EGRESS
SECTION 605 ACCESSIBILITY
27 SECTION 606 STRUCTURAL
SECTION 607 ENERGY CONSERVATION RESERVED
28 SECTION 608 ELECTRICAL
SECTION 609 MECHANICAL
SECTION 610 PLUMBING
SECTION 611 REROOFING
30 TABLE 611.7.1.2 SUPPLEMENT FASTENERS AT PANEL EDGES AND INTERMEDIATE FRAMING
31 TABLE 611.8.1 REQUIRED UPLIFT CAPACITIES FOR ROOF-TO-WALL CONNECTIONSa, b (POUNDS PER LINEAR FOOT)
33 SECTION 612 ENERGY CONSERVATION
SECTION 613 RESIDENTIAL SWIMMING POOLS AND SPAS
34 CHAPTER 7 ALTERATIONS—LEVEL 2
SECTION 701 GENERAL
SECTION 702 SPECIAL USE AND OCCUPANCY RESERVED
SECTION 703 BUILDING ELEMENTS AND MATERIALS
35 SECTION 704 FIRE PROTECTION
36 SECTION 705 MEANS OF EGRESS
38 SECTION 706 ACCESSIBILITY
SECTION 707 STRUCTURAL
39 SECTION 708 ELECTRICAL
SECTION 709 MECHANICAL
SECTION 710 PLUMBING
40 SECTION 711 ENERGY CONSERVATION
42 CHAPTER 8 ALTERATIONS—LEVEL 3
SECTION 801 GENERAL
SECTION 802 SPECIAL USE AND OCCUPANCY
SECTION 803 BUILDING ELEMENTS AND MATERIALS
43 SECTION 804 FIRE PROTECTION
SECTION 805 MEANS OF EGRESS
SECTION 806 ACCESSIBILITY
SECTION 807 STRUCTURAL
SECTION 808 ENERGY CONSERVATION
44 CHAPTER 9 CHANGE OF OCCUPANCY
SECTION 901 GENERAL
SECTION 902 SPECIAL USE AND OCCUPANCY
SECTION 903 BUILDING ELEMENTS AND MATERIALS
SECTION 904 FIRE PROTECTION
SECTION 905 MEANS OF EGRESS
SECTION 906 ACCESSIBILITY
SECTION 907 STRUCTURAL
45 SECTION 908 ELECTRICAL
SECTION 909 MECHANICAL
SECTION 910 PLUMBING
SECTION 911 OTHER REQUIREMENTS
46 SECTION 912 CHANGE OF OCCUPANCY CLASSIFICATION
TABLE 912.4 MEANS OF EGRESS HAZARD CATEGORIES
47 TABLE 912.5 HEIGHTS AND AREAS HAZARD CATEGORIES
TABLE 912.6 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES
48 SECTION 913 ENERGY CONSERVATION
50 CHAPTER 10 ADDITIONS
SECTION 1001 GENERAL
SECTION 1002 HEIGHTS AND AREAS
SECTION 1003 STRUCTURAL
51 SECTION 1004 SMOKE ALARMS IN OCCUPANCY GROUPS R-3 AND R-4
SECTION 1005 ACCESSIBILITY
SECTION 1006 ENERGY CONSERVATION
52 CHAPTER 11 HISTORIC BUILDINGS
SECTION 1101 GENERAL
SECTION 1102 DEFINITION
53 SECTION 1103 STANDARDS AND GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS
SECTION 1104 EQUIVALENCY
SECTION 1105 COMPLIANCE
SECTION 1106 INVESTIGATION AND EVALUATION
54 SECTION 1107 HISTORIC CUBAN TILE
56 CHAPTER 12 RELOCATED OR MOVED BUILDINGS
SECTION 1201 GENERAL
SECTION 1202 REQUIREMENTS
58 CHAPTER 13 PERFORMANCE COMPLIANCE METHODS
SECTION 1301 GENERAL
59 EQUATION 13-1
EQUATION 13-2
EQUATION 13-3
60 EQUATION 13-4
TABLE 1301.6.3 COMPARTMENTATION VALUES
TABLE 1301.6.4 SEPARATION VALUES
61 TABLE 1301.6.5 CORRIDOR WALL VALUES
TABLE 1301.6.6(1) VERTICAL OPENING PROTECTION VALUE
EQUATION 13-5
TABLE 1301.6.6(2) TYPE OF CONSTRUCTION
62 TABLE 1301.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 1301.6.9 FIRE ALARM SYSTEM VALUES
TABLE 1301.6.10 SMOKE CONTROL VALUES
63 TABLE 1301.6.11(1) EGRESS WIDTH PER OCCUPANT SERVED
64 TABLE 1301.6.11(2) MEANS OF EGRESS VALUES
TABLE 1301.6.12 DEAD-END VALUES
EQUATION 13-6
TABLE 1301.6.14 ELEVATOR CONTROL VALUES
TABLE 1301.6.15 MEANS-OF-EGRESS EMERGENCY LIGHTING VALUES
65 TABLE 1301.6.16 MIXED OCCUPANCY VALUESa
TABLE 1301.6.17 SPRINKLER SYSTEM VALUES
66 TABLE 1301.6.18 STANDPIPE SYSTEM VALUES
TABLE 1301.6.19 INCIDENTAL ACCESSORY OCCUPANCY VALUESa
67 TABLE 1301.7 SUMMARY SHEET—BUILDING CODE
68 TABLE 1301.8 MANDATORY SAFETY SCORESa
TABLE 1301.9 EVALUATION FORMULASa
70 CHAPTER 14 CONSTRUCTION SAFEGUARDS
SECTION 1401 GENERAL
[B] TABLE 1401.6 PROTECTION OF PEDESTRIANS
71 [B] SECTION 1402 PROTECTION OF ADJOINING PROPERTY
[B] SECTION 1403 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 1404 FIRE EXTINGUISHERS
72 [B] SECTION 1405 MEANS OF EGRESS
[F] SECTION 1406 STANDPIPE SYSTEMS
[F] SECTION 1407 AUTOMATIC SPRINKLER SYSTEM
SECTION 1408 ACCESSIBILITY
[F] SECTION 1409 WATER SUPPLY FOR FIRE PROTECTION
74 CHAPTER 15 REFERENCED STANDARDS
ASCE
ASHRAE
ASME
ASTM
DOC
75 FLORIDA CODES
NFPA
76 CHAPTER 16 RETROFITTING
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS
SECTION 1603 MATERIALS OF CONSTRUCTION
77 FIGURE 1603.6.3 FASTENER SPACINGS FOR LUMBER TO LUMBER CONNECTIONS OPERATING IN SHEAR PARALLEL TO GRAIN
78 SECTION 1604 RETROFITTING GABLE END WALLS
79 FIGURE 1604.1.1 BASIC GABLE END RETROFIT METHODOLOGY
80 TABLE 1604.2 STUD LENGTH LIMITATIONS BASED ON EXPOSURE AND DESIGN WIND SPEED
81 FIGURE 1604.2(1) TRUSS FRAMED GABLE END L-BENT STRAP
82 FIGURE 1604.2(2) CONVENTIONALLY FRAMED GABLE END L-BENT STRAP
83 FIGURE 1604.2(3) TRUSS FRAMED GABLE END U-BENT STRAP
84 FIGURE 1604.2(4) CONVENTIONALLY FRAMED GABLE END U-BENT STRAP
86 FIGURE 1604.2.3 OMITTED HORIZONTAL BRACE
87 FIGURE 1604.2.4(1) DETAIL OF LADDER BRACING FOR OMITTED RETROFIT STUD (TRUSS GABLE END)
88 FIGURE 1604.2.4(2) DETAIL OF LADDER BRACING FOR OMITTED RETROFIT STUD (CONVENTIONAL FRAMING)
90 FIGURE 1604.2.5 DETAIL OF ANCHOR BLOCK INSTALLATION
91 FIGURE 1604.2.7 DETAIL OF RETROFIT TIE INSTALLATION
92 FIGURE 1604.2.8(1) SPLICED HORIZONTAL BRACES
93 FIGURE 1604.2.8(2) SPLICED HORIZONTAL BRACES
94 FIGURE 1604.2.8(3) SPLICED HORIZONTAL BRACES
96 FIGURE 1604.3 METHODS OF INSTALLING RETROFIT STUDS
97 FIGURE 1604.3.4 NAIL PLATE FASTENING
98 FIGURE 1604.3.8 DETAIL OF RETROFIT STUD SPLICE
99 TABLE 1604.4.1 ELEMENT SIZING AND SPACING FOR L-BENT RETROFIT METHOD
TABLE 1604.4.2 ELEMENT SIZING AND SPACING FOR U-BENT RETROFIT METHOD
100 TABLE 1604.5.1 SPACING OF RIGHT ANGLE BRACKETS
TABLE 1604.5.2 SPACING OF LAG OR MASONRY SCREWS USED TO CONNECT SILL PLATE OF GABLE END WALL TO TOP OF THE WALL BELOW
SECTION 1605 RETROFITTING RAKE OVERHANG OUTLOOKERS FOR UPLIFT LOADS
FIGURE 1605.1 RAKE OVERHANG OUTLOOKERS
101 TABLE 1605.2 RAKE OVERHANG OUTLOOKER UPLIFT CONNECTION
102 APPENDIX A GUIDELINES FOR THE SEISMIC RETROFIT OF EXISTING BUILDINGS RESERVED
104 APPENDIX B STANDARD FOR REHABILITATION
INTRODUCTION
105 THE SECRETARY OF THE INTERIOR’S STANDARDS FOR REHABILITATION
106 GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS
108 HEALTH AND SAFETY CODE REQUIREMENTS; ENERGY RETROFITTING
109 BUILDING EXTERIOR
124 BUILDING INTERIOR
132 BUILDING SITE
135 DISTRICT/NEIGHBORHOOD
137 HEALTH AND SAFETY CODE REQUIREMENTS
138 ENERGY RETROFITTING
140 NEW ADDITIONS TO HISTORIC BUILDINGS
142 APPENDIX C
144 APPENDIX D TYPE OF CONSTRUCTION
146 RESOURCE A GUIDELINES ON FIRE RATINGS OF ARCHAIC MATERIALS AND ASSEMBLIES
148 INDEX
152 FLORIDA BUILDING CODE 2010 BUILDING CHAPTER 1 TITLE PAGE
154 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
156 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY RESERVED
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
157 SECTION 105 PERMITS
160 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
164 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
167 SECTION 111 CERTIFICATE OF OCCUPANCY
168 SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS RESERVED
SECTION 114 VIOLATIONS RESERVED
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT RESERVED
170 COMMITTED TO BUILDING A GREEN AND SUSTAINABLE WORLD
171 ICC PLAN REVIEW SERVICES