Shopping Cart

No products in the cart.

FL FloridaBuildingCode 2020

$68.75

Florida Building Code – Building, Seventh Edition

Published By Publication Date Number of Pages
FL 2020 871
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 7th Edition (2020) update to the Florida Building Code: Building is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Building using the latest changes to the 2018 International Building CodeÂź with customized amendments adopted statewide. Chapter tabs are also included. Effective Date: December 31, 2020

PDF Catalog

PDF Pages PDF Title
1 FLORIDA BUILDING CODE – BULDING, SEVENTH EDITION (2020)
2 FLORIDA BUILDING CODE – BULDING, SEVENTH EDITION (2020) TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
16 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
19 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
SECTION 105 PERMITS
25 SECTION 106 FLOOR AND ROOF DESIGN LOADS
26 SECTION 107 SUBMITTAL DOCUMENTS
30 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
34 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
35 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
SECTION 117 VARIANCES IN FLOOD HAZARD AREAS
36 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
68 CHAPTER 3 USE AND OCCUPANCY CLASSIFICATION
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
69 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
70 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
72 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
73 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARD
74 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIAL POSING A HEALTH HAZARD
75 SECTION 308 INSTITUTIONAL GROUP I
76 SECTION 309 MERCANTILE GROUP M
77 SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
78 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
80 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
83 EQUATION 4-1
84 SECTION 403 HIGH-RISE BUILDINGS
85 TABLE 403.2.4 MINIMUM BOND STRENGTH
87 SECTION 404 ATRIUMS
88 SECTION 405 UNDERGROUND BUILDINGS
89 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
92 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
93 SECTION 407 GROUP I-2
97 SECTION 408 GROUP I-3
99 SECTION 409 MOTION PICTURE PROJECTION ROOMS
100 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
102 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
TABLE 412.3.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
104 [F] TABLE 412.4.6 HANGAR FIRE SUPPRESSION REQUIREMENTS
105 TABLE 412.7 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
106 SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
[F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
108 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDS
[F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREA
109 SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
110 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTS
112 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
115 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5
119 SECTION 416 APPLICATION OF FLAMMABLE FINISHES
SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
120 SECTION 419 LIVE/WORK UNITS
SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
121 SECTION 421 HYDROGEN FUEL GAS ROOMS
122 SECTION 422 AMBULATORY CARE FACIILITIES
SECTION 423 STORM SHELTERS
123 SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
124 SECTIONS [F] 427 THROUGH 448 RESERVED
SECTION 449 HOSPITALS
131 SECTION 450 NURSING HOMES
140 SECTION 451 AMBULATORY SURGICAL CENTERS
144 SECTION 452 BIRTHING CENTERS
145 SECTION 453 STATE REQUIREMENTS FOR EDUCATIONAL FACILITIES
152 TABLE 453.10.3.7(1) LIGHT POLLUTION ZONES
TABLE 453.10.3.7(2) MAXIMUM ALLOWABLE BACKLIGHT RATINGS
164 SECTION 454 SWIMMING POOLS AND BATHING PLACES (PUBLIC AND PRIVATE)
174 TABLE 454.1.6.1 PUBLIC SWIMMING POOL—REQUIRED FIXTURE COUNT
195 SECTION 455 PUBLIC LODGING ESTABLISHMENTS
196 SECTION 456 PUBLIC FOOD SERVICE ESTABLISHMENTS
197 SECTION 457 MENTAL HEALTH PROGRAMS
206 SECTION 458 MANUFACTURED BUILDINGS
208 SECTION 459 BOOT CAMPS FOR CHILDREN
SECTION 460 MAUSOLEUMS AND COLUMBARIUMS
210 SECTION 461 TRANSIENT PUBLIC LODGING ESTABLISHMENTS
SECTION 462 USE OF ASBESTOS IN NEW PUBLIC BUILDINGS OR BUILDINGS NEWLY CONSTRUCTED FOR LEASE TO GOVERNMENT ENTITIES—PROHIBITION
SECTION 463 ADULT DAY CARE
211 SECTION 464 ASSISTED LIVING FACILITIES
214 SECTION 465 CONTROL OF RADIATION HAZARDS
216 TIME-TEMPERATURE CHART
219 SECTION 466 DAY CARE OCCUPANCIES
TABLE 466.5 DAY CARE LOCATION AND TYPE OF CONSTRUCTION
221 SECTION 467 HOSPICE INPATIENT FACILITIES AND UNITS AND HOSPICE RESIDENTIAL FACILITIES
224 SECTION 468 SCHOOLS, COLLEGES AND UNIVERSITIES
226 SECTION 469 OFFICE SURGERY SUITE
230 TABLE 469.4.11.1.3 MINIMUM STATION OUTLETS FOR PIPED GAS SYSTEMS IN OFFICE SURGERY SUITES
232 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 DEFINITIONS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
233 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
234 TABLE 504.3a ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE
235 TABLE 504.4a, b ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
236 TABLE 504.4a, b—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE
SECTION 506 BUILDING AREA
237 EQUATION 5-1
EQUATION 5-2
EQUATION 5-3
238 TABLE 506.2a, b ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
239 TABLE 506.2a, b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
240 TABLE 506.2a, b—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET
EQUATION 5-4
EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
242 SECTION 508 MIXED USE AND OCCUPANCY
243 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
244 SECTION 509 INCIDENTAL USES
TABLE 509 INCIDENTAL USES
245 SECTION 510 SPECIAL PROVISIONS
248 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
249 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
252 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 DEFINITIONS
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
253 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
255 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
256 EQUATION 7-1
257 FIGURE 705.7 EQUIVALENT OPENING FACTOR
EQUATION 7-2
258 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
259 SECTION 706 FIRE WALLS
260 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
262 SECTION 707 FIRE BARRIERS
TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEMBLIES OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
263 SECTION 708 FIRE PARTITIONS
264 SECTION 709 SMOKE BARRIERS
265 SECTION 710 SMOKE PARTITIONS
266 SECTION 711 FLOOR AND ROOF ASSEMBLIES
SECTION 712 VERTICAL OPENINGS
268 SECTION 713 SHAFT ENCLOSURES
269 SECTION 714 PENETRATIONS
272 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
273 SECTION 716 OPENING PROTECTIVES
TABLE 716.3 MARKING FIRE-RATED GLAZING ASSEMBLIES
275 TABLE 716.5 OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
276 TABLE 716.5—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
278 TABLE 716.6 FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
279 SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
280 TABLE 717.3.2.1 FIRE DAMPER RATING
284 SECTION 718 CONCEALED SPACES
286 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
287 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
288 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
289 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
290 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
291 TABLE 721.1(1) —continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
292 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
293 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
294 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
295 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
296 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
297 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
298 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
299 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
300 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONSa, o, p
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
301 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
302 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
303 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
304 TABLE 721.1(3) —continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
305 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
306 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
307 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
308 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
309 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
310 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
311 SECTION 722 CALCULATED FIRE RESISTANCE
TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
312 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
313 FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
314 TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
315 FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
316 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
317 TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
318 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
319 EQUATION 7-6
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLSa, b, c, d
320 EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
321 TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
322 TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
323 FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
324 FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1 (5)WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
EQUATION 7-12
325 EQUATION 7-13
EQUATION 7-14
EQUATION 7-15
326 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa,b
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-16
327 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
329 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
330 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
331 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
332 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
333 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
334 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
335 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
336 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
337 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
338 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAMEa, b, c
339 TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
340 CHAPTER 8 INTERIOR FINISHES
SECTION 801 GENERAL
SECTION 802 DEFINITIONS
SECTION 803 WALL AND CEILING FINISHES
342 TABLE 803.11 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
343 SECTION 804 INTERIOR FLOOR FINISH
SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
344 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
346 CHAPTER 9 FIRE PROTECTION SYSTEMS
SECTION 901 GENERAL
SECTION 902 DEFINITIONS
347 SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
349 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
351 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
354 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
356 SECTION 905 STANDPIPE SYSTEMS
359 SECTION 906 PORTABLE FIRE EXTINGUISHERS
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCH
360 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
370 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
371 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
373 EQUATION 9-1
EQUATION 9-2
379 SECTION 910 SMOKE AND HEAT REMOVAL
380 EQUATION 9-3
EQUATION 9-4
SECTION 911 FIRE COMMAND CENTER
381 SECTION 912 FIRE DEPARTMENT CONNECTIONS
382 SECTION 913 FIRE PUMPS
383 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE PROTECTION
SECTION 916 GAS DETECTION SYSTEMS
384 SECTION 917 EMERGENCY RESPONDER RADIO COVERAGE
386 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
SECTION 1002 DEFINITIONS
SECTION 1003 GENERAL MEANS OF EGRESS
388 SECTION 1004 OCCUPANT LOAD
TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
389 SECTION 1005 MEANS OF EGRESS SIZING
390 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
391 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
392 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
393 TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
394 SECTION 1008 MEANS OF EGRESS ILLUMINATION
395 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
SECTION 1010 DOORS, GATES AND TURNSTILES
396 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
397 TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
399 TABLE 1010.1.7 EXTERIOR FLOOR LEVEL DIFFERENCE
404 SECTION 1011 STAIRWAYS
407 SECTION 1012 RAMPS
408 SECTION 1013 EXIT SIGNS
409 SECTION 1014 HANDRAILS
410 SECTION 1015 GUARDS
412 SECTION 1016 EXIT ACCESS
413 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
SECTION 1018 AISLES
414 SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
SECTION 1020 CORRIDORS
415 TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
416 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
417 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
418 SECTION 1024 EXIT PASSAGEWAYS
419 SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
421 SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
422 SECTION 1028 EXIT DISCHARGE
423 SECTION 1029 ASSEMBLY
424 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
428 TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
430 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
432 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 DEFINITIONS
SECTION 1103 SCOPING REQUIREMENTS
SECTION 1104 ACCESSIBLE ROUTE
SECTION 1105 ACCESSIBLE ENTRANCES
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
SECTION 1108 SPECIAL OCCUPANCIES
SECTION 1109 OTHER FEATURES AND FACILITIES
SECTION 1110 RECREATIONAL FACILITIES
SECTION 1111 SIGNAGE
434 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
SECTION 1203 VENTILATION
435 TABLE 1203.3 INSULATION FOR CONDENSATION CONTROL
436 SECTION 1204 TEMPERATURE CONTROL
SECTION 1205 LIGHTING
437 SECTION 1206 YARDS OR COURTS
SECTION 1207 SOUND TRANSMISSION
SECTION 1208 INTERIOR SPACE DIMENSIONS
438 SECTION 1209 ACCESS TO UNOCCUPIED SPACES
SECTION 1210 TOILET AND BATHROOM REQUIREMENTS
440 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
442 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 DEFINITIONS
SECTION 1403 PERFORMANCE REQUIREMENTS
443 SECTION 1404 MATERIALS
444 SECTION 1405 INSTALLATION OF WALL COVERINGS
445 TABLE 1405.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1405.3.2 CLASS III VAPOR RETARDERS
450 SECTION 1406 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
451 TABLE 1406.2.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
SECTION 1407 METAL COMPOSITE MATERIALS (MCM)
452 SECTION 1408 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1409 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
453 SECTION 1410 PLASTIC COMPOSITE DECKING
454 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 DEFINITIONS
455 SECTION 1503 WEATHER PROTECTION
TABLE 1503.2 METAL FLASHING MATERIAL
456 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.3.3 CLASSIFICATION OF METAL ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D3161
457 SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
458 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
459 TABLE 1507.1.1.1 UNDERLAYMENT WITH SELF-ADHERING STRIPS OVER ROOF DECKING JOINTS
461 TABLE 1507.2.7.1 CLASSIFICATION OF ASPHALT SHINGLES
463 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
464 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
465 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
466 TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
SECTION 1508 ROOF INSULATION
467 [BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
469 TABLE 1510.10 CLEARANCE BELOW RAISED ROOF MOUNTED MECHANICAL UNITS
470 SECTION 1511 EXISTING ROOFING
SECTION 1512 HIGH-VELOCITY HURRICANE ZONES—GENERAL
472 SECTION 1513 HIGH-VELOCITY HURRICANE ZONES—DEFINITIONS
473 SECTION 1514 HIGH-VELOCITY HURRICANE ZONES—WEATHER PROTECTION
474 SECTION 1515 HIGH-VELOCITY HURRICANE ZONES—PERFORMANCE REQUIREMENTS
475 TABLE 1515.2 MINIMUM SLOPE
SECTION 1516 HIGH-VELOCITY HURRICANE ZONES—FIRE CLASSIFICATION
SECTION 1517 HIGH-VELOCITY HURRICANE ZONES—MATERIALS
476 SECTION 1518 HIGH-VELOCITY HURRICANE ZONES—ROOF COVERINGS WITH SLOPES 2:12 OR GREATER
479 SECTION 1519 HIGH-VELOCITY HURRICANE ZONES—ROOF COVERINGS WITH SLOPES LESS THAN 2:12
TABLE 1519.3A SLOPE AND APPLICATION TEMPERATURE CRITERIA
TABLE 1519.3B SLOPE AND APPLICATION TEMPERATURE CRITERIA
481 SECTION 1520 HIGH-VELOCITY HURRICANE ZONES—ROOF INSULATION
482 SECTION 1521 HIGH-VELOCITY HURRICANE ZONES—REROOFING
483 SECTION 1522 HIGH-VELOCITY HURRICANE ZONES—ROOFTOP STRUCTURES AND COMPONENTS
TABLE 1522.3 ROOF MOUNTED EQUIPMENT HEIGHT REQUIREMENTS
484 SECTION 1523 HIGH-VELOCITY HURRICANE ZONES—TESTING
487 SECTION 1524 HIGH-VELOCITY HURRICANE ZONES—REQUIRED OWNER’S NOTIFICATION FOR ROOFING CONSIDERATIONS
488 SECTION 1525 HIGH-VELOCITY HURRICANE ZONES—UNIFORM PERMIT APPLICATION
FLORIDA BUILDING CODE 7TH EDITION (2020) HIGH-VELOCITY HURRICANE ZONE UNIFORM PERMIT APPLICATION FORM
INSTRUCTION PAGE
ATTACHMENTS REQUIRED
489 Section A (General Information)
Section B (Roof Plan)
490 Section C (Low Slope Application)
491 Section D (Steep Sloped Roof System)
492 Section E (Tile Calculations)
494 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 DEFINITIONS AND NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
496 SECTION 1604 GENERAL DESIGN REQUIREMENTS
TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i
498 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
499 SECTION 1605 LOAD COMBINATIONS
EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
500 EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
501 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
502 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
504 EQUATOIN 16-23
TABLE 1607.10.1 LIVE LOAD ELEMENT FACTOR, KLL
505 EQUATION 16-24
EQUATION 16-25
EQUATION 16-26
506 EQUATOIN 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATOIN 16-32
507 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
508 SECTION 1609 WIND LOADS
509 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
510 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
512 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONSa, b, c
513 FIGURE 1609.3(1) ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
514 FIGURE 1609.3(2) ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
515 FIGURE 1609.3(3) ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
516 FIGURE 1609.3(4) ULTIMATE DESIGN WIND SPEEDS, VULT, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
517 EQUATION 16-34
518 TABLE 1609.6(1) NOMINAL (ASD) GARAGE DOOR AND ROLLING DOOR WIND LOADS FOR A BUILDING WITH A MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (PSF)
TABLE 1609.6(2) ADJUSTMENT FACTOR FOR BUILDING HEIGHT AND EXPOSURE, (λ)
SECTION 1610 SOIL LATERAL LOADS
519 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1611 RAIN LOADS
EQUATION 16-36
SECTION 1612 FLOOD LOADS
521 [P] FIGURE 1611.1100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
522 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
523 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
524 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
525 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HAWAII
526 TABLE 1612.1 CROSS REFERENCES DEFINING FLOOD-RESISTANT PROVISIONS OF THE FLORIDA BUILDING CODE
527 TABLE 1612.1—continued CROSS REFERENCES DEFINING FLOOD-RESISTANT PROVISIONS OF THE FLORIDA BUILDING CODE
528 SECTION 1613 EARTHQUAKE LOADS
529 EQUATION 16-37
EQUATION 16-38
EQUATION 16-39
EQUATION 16-40
TABLE 1613.3.3(1) VALUES OF SITE COEFFICIENT Fa a
TABLE 1613.3.3(2) VALUES OF SITE COEFFICIENT FV a
530 TABLE 1613.3.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.3.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
531 FIGURE 1613.3.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
532 FIGURE 1613.3.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
533 FIGURE 1613.3.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
534 FIGURE 1613.3.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
535 FIGURE 1613.3.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
536 FIGURE 1613.3.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
537 FIGURE 1613.3.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
538 FIGURE 1613.3.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
539 FIGURE 1613.3.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
540 FIGURE 1613.3.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING), SITE CLASS B
541 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 STRUCTURAL INTEGRITY
EQUATION 16-41
542 EQUATION 16-42
FIGURE 1615.4 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
SECTION 1616 HIGH-VELOCITY HURRICANE ZONES—GENERAL, DEFLECTION, VOLUME CHANGES AND MINIMUM LOADS
543 SECTION 1617 HIGH-VELOCITY HURRICANE ZONES—ROOF DRAINAGE
SECTION 1618 HIGH-VELOCITY HURRICANE ZONES—SPECIAL LOAD CONSIDERATIONS
544 SECTION 1619 HIGH VELOCITY HURRICANE ZONES—LIVE LOAD REDUCTIONS
SECTION 1620 HIGH-VELOCITY HURRICANE ZONES—WIND LOADS
SECTION 1621 HIGH-VELOCITY HURRICANE ZONES—OVERTURNING MOMENT AND UPLIFT
SECTION 1622 HIGH-VELOCITY HURRICANE ZONES—SCREEN ENCLOSURES
545 SECTION 1623 HIGH-VELOCITY HURRICANE ZONES—LIVE LOADS POSTED AND OCCUPANCY PERMITS
SECTION 1624 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION DESIGN
SECTION 1625 HIGH-VELOCITY HURRICANE ZONES—LOAD TESTS
TABLE 1625.4 FATIGUE LOADING SEQUENCE
SECTION 1626 HIGH-VELOCITY HURRICANE ZONES—IMPACT TESTS FOR WIND-BORNE DEBRIS
547 TABLE 1626 CYCLIC WIND PRESSURE LOADING
550 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
SECTION 1703 APPROVALS
551 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
552 SECTION 1709 PRECONSTRUCTION LOAD TESTS
555 SECTION 1710 ANCHORAGE
558 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DEFINITIONS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
560 SECTION 1804 EXCAVATION, GRADING AND FILL
561 SECTION 1805 DAMPPROOFING AND WATERPROOFING
562 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
563 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
564 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLS
565 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLS
566 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≄ 5 INCHES
567 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≄ 6.75 INCHES
568 EQUATION 18-1
TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≄ 8.75 INCHES
569 EQUATION 18-2
EQUATION 18-3
SECTION 1808 FOUNDATIONS
570 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
571 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH fâ€Č C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
572 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTION
573 SECTION 1810 DEEP FOUNDATIONS
576 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
578 EQUATION 18-4
580 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
581 EQUATION 18-9
EQUATION 18-10
EQUATION 18-11
586 SECTIONS 1811 THROUGH 1815 RESERVED
SECTION 1816 TERMITE PROTECTION
587 SECTION 1817 HIGH-VELOCITY HURRICANE ZONES—EXCAVATIONS
SECTION 1818 HIGH-VELOCITY HURRICANE ZONES—BEARING CAPACITY OF SOIL
SECTION 1819 HIGH-VELOCITY HURRICANE ZONES—SOIL BEARING FOUNDATIONS
SECTION 1820 HIGH-VELOCITY HURRICANE ZONES—CONCRETE SLABS ON FILL
SECTION 1821 HIGH-VELOCITY HURRICANE ZONES—MONOLITHIC FOOTINGS
SECTION 1822 HIGH-VELOCITY HURRICANE ZONES—PILE FOUNDATIONS
SECTION 1823 HIGH-VELOCITY HURRICANE ZONES—WOOD PILES
SECTION 1824 HIGH-VELOCITY HURRICANE ZONES—PRECAST CONCRETE PILES
SECTION 1825 HIGH-VELOCITY HURRICANE ZONES—PRESTRESSED PRECAST CONCRETE PILES
SECTION 1826 HIGH-VELOCITY HURRICANE ZONES—CAST-IN-PLACE
SECTION 1827 HIGH-VELOCITY HURRICANE ZONES—ROLLED STRUCTURAL SHAPES
SECTION 1828 HIGH-VELOCITY HURRICANE ZONES—SPECIAL PILES OR SPECIAL CONDITIONS
SECTION 1829 HIGH-VELOCITY HURRICANE ZONES—LOAD TESTS ON PILES
SECTION 1830 HIGH-VELOCITY HURRICANE ZONES—FOUNDATION WALLS AND GRADE BEAMS
SECTION 1831 HIGH-VELOCITY HURRICANE ZONES—GRADES UNDER BUILDINGS
SECTION 1832 HIGH-VELOCITY HURRICANE ZONES—RETAINING WALLS
SECTION 1833 HIGH-VELOCITY HURRICANE ZONES—SEAWALLS AND BULKHEADS
SECTION 1834 HIGH-VELOCITY HURRICANE ZONES—SOIL IMPROVEMENT
588 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
SECTION 1904 DURABILITY REQUIREMENTS
589 SECTION 1905 MODIFICATIONS TO ACI 318
591 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
592 SECTION 1908 SHOTCRETE
593 SECTION 1909 SPECIAL WIND PROVISIONS FOR CONCRETE
SECTIONS 1910 THROUGH 1916 RESERVED
SECTION 1917 LIGHTWEIGHT INSULATING CONCRETE ROOFS
594 SECTION 1918 RESERVED
SECTION 1919 HIGH-VELOCITY HURRICANE ZONES—GENERAL
595 SECTION 1920 HIGH-VELOCITY HURRICANE ZONES—STANDARDS
SECTION 1921 HIGH-VELOCITY HURRICANE ZONES—DEFINITIONS
SECTION 1922 HIGH-VELOCITY HURRICANE ZONES—MATERIALS
SECTION 1923 HIGH-VELOCITY HURRICANE ZONES—CONCRETE QUALITY
SECTION 1924 HIGH-VELOCITY HURRICANE ZONES—MIXING AND PLACING CONCRETE
SECTION 1925 HIGH-VELOCITY HURRICANE ZONES—FORM WORK, EMBEDDED PIPES AND CONSTRUCTION JOINTS
SECTION 1926 HIGH-VELOCITY HURRICANE ZONES—DETAILS OF REINFORCEMENT
SECTION 1927 HIGH-VELOCITY HURRICANE ZONES—PRECAST CONCRETE UNITS
SECTION 1928 HIGH-VELOCITY HURRICANE ZONES—PRESTRESSED CONCRETE
SECTION 1929 HIGH-VELOCITY HURRICANE ZONES—PNEUMATICALLY PLACED CONCRETE (SHOTCRETE)
596 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
TABLE 2002.4A HEIGHT ADJUSTMENT FACTORS
597 TABLE 2002.4 DESIGN WIND PRESSURES SCREENED ENCLOSURESa, b, f, g, h (STRENGTH DESIGN OR LRFD ONLY)
598 SECTION 2003 HIGH-VELOCITY HURRICANE ZONES—ALUMINUM
600 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 DEFINITIONS AND NOTATIONS
601 SECTION 2103 MASONRY CONSTRUCTION MATERIALS
TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
602 SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
EQUATION 21-1
603 SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 DRY-STACK MASONRY
TABLE 2109.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
605 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
606 SECTION 2112 MASONRY HEATERS
SECTION 2113 MASONRY CHIMNEYS
609 TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
610 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
611 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 TERMITE INSPECTION
SECTION 2115 SPECIAL WIND PROVISIONS FOR MASONRY
SECTIONS 2116 AND 2117 RESERVED
SECTION 2118 HIGH-VELOCITY HURRICANE ZONES—DESIGN
SECTION 2119 HIGH-VELOCITY HURRICANE ZONES—QUALITY, TESTS AND APPROVALS
612 SECTION 2120 HIGH-VELOCITY HURRICANE ZONES—ALLOWABLE UNIT STRESSES IN UNIT MASONRY
SECTION 2121 HIGH-VELOCITY HURRICANE ZONES—CONSTRUCTION DETAILS
615 SECTION 2122 HIGH-VELOCITY HURRICANE ZONES—REINFORCED UNIT MASONRY
618 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 DEFINITIONS
SECTION 2203 IDENTIFICATION AND PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
619 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
620 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
621 SECTION 2212 GABLE END WALLS
SECTION 2213 RESERVED
SECTION 2214 HIGH-VELOCITY HURRICANE ZONES—GENERAL—STEEL CONSTRUCTION
622 SECTION 2215 HIGH-VELOCITY HURRICANE ZONES—MATERIAL
SECTION 2216 HIGH-VELOCITY HURRICANE ZONES—DESIGN LOADS
SECTION 2217 HIGH-VELOCITY HURRICANE ZONES—MINIMUM THICKNESS OF MATERIAL
SECTION 2218 HIGH-VELOCITY HURRICANE ZONES—CONNECTIONS
SECTION 2219 HIGH-VELOCITY HURRICANE ZONES—TUBULAR COLUMNS
SECTION 2220 HIGH-VELOCITY HURRICANE ZONES—PROTECTION OF METAL
623 SECTION 2221 HIGH-VELOCITY HURRICANE ZONES—GENERAL—OPEN WEB STEEL JOISTS
SECTION 2222 HIGH-VELOCITY HURRICANE ZONES—COLD-FORMED STEEL CONSTRUCTION
624 SECTION 2223 HIGH-VELOCITY HURRICANE ZONES—PREENGINEERED, PREFABRICATED METAL BUILDING SYSTEMS AND COMPONENTS (PREENGINEERED STRUCTURES)
625 SECTION 2224 HIGH-VELOCITY HURRICANE ZONES—CHAIN LINK FENCES
TABLE 2224 CHAIN LINK FENCE MINIMUM REQUIREMENTS
626 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DEFINITIONS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
630 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
631 TABLE 2304.6.1 MAXIMUM NOMINAL DESIGN WIND SPEED, Vasd, PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURES
632 TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHINGa
TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTS
633 TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood Structural Panels Are Five-Ply, Five-Layer Unless Otherwise Noted)
634 TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
636 TABLE 2304.10.1 FASTENING SCHEDULE
637 TABLE 2304.10.1—continued FASTENING SCHEDULE
638 TABLE 2304.10.1—continued FASTENING SCHEDULE
639 TABLE 2304.10.1—continued FASTENING SCHEDULE
640 TABLE 2304.10.1—continued FASTENING SCHEDULE
641 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
644 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1) en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c
EQUATION 23-2
645 TABLE 2305.2(2) VALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
646 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
647 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
648 TABLE 2306.2(1)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
649 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
650 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
651 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADING
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLY
SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
652 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
SECTION 2310 THROUGH 2313 RESERVED
653 SECTION 2314 HIGH-VELOCITY HURRICANE ZONES
654 SECTION 2315 HIGH-VELOCITY HURRICANE ZONES—QUALITY
655 SECTION 2316 HIGH-VELOCITY HURRICANE ZONES—SIZES
SECTION 2317 HIGH-VELOCITY HURRICANE ZONES—UNIT STRESSES
SECTION 2318
HIGH-VELOCITY HURRICANE ZONES—
VERTICAL FRAMING
656 SECTION 2319 HIGH-VELOCITY HURRICANE ZONES—HORIZONTAL FRAMING
661 SECTION 2320 HIGH-VELOCITY HURRICANE ZONES—FIRESTOPS
SECTION 2321 HIGH-VELOCITY HURRICANE ZONES—ANCHORAGE
662 SECTION 2322 HIGH-VELOCITY HURRICANE ZONES—SHEATHING
TABLE 2322.1.6 PLYWOOD SUBFLOOR1
663 TABLE 2322.2.3 ALLOWABLE SPAN FOR PLYWOOD ROOF SHEATHING1
664 SECTION 2323 HIGH-VELOCITY HURRICANE ZONES—FURRING
SECTION 2324 HIGH-VELOCITY HURRICANE ZONES—CONNECTORS
TABLE 2324.1 NAIL CONNECTION FOR WOOD MEMBERS
SECTION 2325 HIGH-VELOCITY HURRICANE ZONES—WOOD SUPPORTING MASONRY
SECTION 2326 HIGH-VELOCITY HURRICANE ZONES—PROTECTION OF WOOD
665 SECTION 2327 HIGH-VELOCITY HURRICANE ZONES—FIRE-RETARDANT WOOD
SECTION 2328 HIGH-VELOCITY HURRICANE ZONES—WOOD FENCES
SECTION 2329 HIGH-VELOCITY HURRICANE ZONES—FIRE-RETARDANT-TREATED SHAKES AND SHINGLES
SECTION 2330 HIGH-VELOCITY HURRICANE ZONES—WOOD BLOCKING
666 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 DEFINITIONS
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
667 EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
EQUATION 24-12
668 SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
669 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
670 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
671 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
672 SECTION 2408 GLAZING IN ATHLETIC FACILITIES
SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
673 SECTION 2410 HIGH-VELOCITY HURRICANE ZONES—GENERAL
SECTION 2411 HIGH-VELOCITY HURRICANE ZONES—WINDOWS, DOORS, GLASS AND GLAZING
675 SECTION 2412 HIGH-VELOCITY HURRICANE ZONES—GLASS VENEER
676 SECTION 2413 HIGH-VELOCITY HURRICANE ZONES—STORM SHUTTERS/EXTERNAL PROTECTIVE DEVICES
SECTION 2414 HIGH-VELOCITY HURRICANE ZONES—CURTAIN WALLS
677 SECTION 2415 HIGH-VELOCITY HURRICANE ZONES—STRUCTURAL GLAZING SYSTEMS
680 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 DEFINITIONS
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
SECTION 2507 LATHING AND PLASTERING
681 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
SECTION 2508 GYPSUM CONSTRUCTION
682 TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
TABLE 2508.6 ALLOWABLE (ASD) SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
683 SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
684 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
685 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
SECTION 2515 HIGH-VELOCITY HURRICANE ZONES—LATHING
SECTION 2516 HIGH-VELOCITY HURRICANE ZONES—PLASTER
SECTION 2517 HIGH-VELOCITY HURRICANE ZONES—STUCCO
686 SECTION 2518 HIGH-VELOCITY HURRICANE ZONES—GYPSUM BOARD PRODUCTS AND ACCESSORY ITEMS
SECTION 2519 HIGH-VELOCITY HURRICANE ZONES—SUSPENDED AND FURRED CEILINGS
SECTION 2520 HIGH-VELOCITY HURRICANE ZONES—ASBESTOS
SECTION 2521 HIGH-VELOCITY HURRICANE ZONES—TILE
688 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 DEFINITIONS
SECTION 2603 FOAM PLASTIC INSULATION
692 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
693 TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
694 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHT
SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
695 SECTION 2606 LIGHT-TRANSMITTING PLASTICS
696 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
697 SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
698 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
699 SECTION 2613 FIBER-REINFORCED POLYMER
700 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
SECTION 2615 HIGH-VELOCITY HURRICANE ZONES—PLASTICS
702 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
704 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
706 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
[P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
707 [P] TABLE 2902.1—(continued) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
708 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
710 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.2 STANDARDS FOR ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
711 SECTION 3002 HOISTWAY ENCLOSURES
712 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
713 SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
714 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
715 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
716 SECTION 3008 OCCUPANT EVACUATION ELEVATORS
718 SECTION 3009 ELEVATOR ACCESSIBILITY REQUIREMENTS FOR THE PHYSICALLY HANDICAPPED
SECTION 3010 SERIAL NUMBERS
719 SECTION 3011 ELECTROLYSIS PROTECTION FOR UNDERGROUND HYDRAULIC ELEVATOR CYLINDERS
SECTION 3012 ALTERATIONS TO ELECTRIC AND HYDRAULIC ELEVATORS AND ESCALATORS
SECTION 3013 CLEARANCE REQUIREMENTS BETWEEN ELEVATOR DOORS FOR ELEVATORS INSIDE A PRIVATE RESIDENCE
722 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
723 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
725 SECTION 3105 AWNINGS AND CANOPIES
726 SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
727 SECTION 3109 STRUCTURES SEAWARD OF A COASTAL CONSTRUCTION CONTROL LINE
729 SECTION 3110 AUTOMATIC VEHICULAR GATES
730 SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 DEPOSIT OF MATERIAL IN TIDEWATER REGULATED
731 SECTION 3113 LIGHTING, MIRRORS, LANDSCAPING
SECTION 3114 AIRPORT NOISE
732 SECTION 3115 EXTERIOR ELEVATED FLOORING SYSTEMS
734 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
736 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
737 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
738 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
SECTION 3311 STANDPIPES
739 SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
740 CHAPTER 34 RESERVED
742 CHAPTER 35 REFERENCED STANDARDS
AA
AAF
AAMA
743 ACI
AF & PA
AHA
AISC
744 AISI
AITC
745 ALI
AMCA
ANSI
746 APA
APSP
747 ASABE
ASCE/SEI
ASHRAE
748 ASME
ASSE
749 ASTM
757 AWC
AWPA
758 AWS
BHMA
CEN
CGSB
759 CISCA
CPA
CPSC
CSA
760 CSSB
DASMA
DECO
DOC/NIST
761 DOL/OSHA
DOTn
FDOE
FEMA
762 FGI
FINA
Florida Codes
764 FM
FRSA
765 FS
GA
GSA
HPVA
ICC
766 IEEE
IESNA
ISO
MHI
MIA
767 NAAMM
NCMA
NFPA
769 NSF
PCI
PTI
770 RCSC
RMI
SBCA
SDI
771 SJI
SPRI
STI
TECO
772 TIA
TMS
TPI
773 UL
774 ULC
USC
775 WCLIB
WDMA
WRI
776 CHAPTER 36 FLORIDA FIRE PREVENTION CODE
SECTION 3601
778 APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
780 APPENDIX B CHAPTER 9B-52 F.A.C.FLORIDA STANDARD FOR PASSIVE RADON-RESISTANT CONSTRUCTION
781 FLORIDA STANDARD FOR PASSIVE RADON-RESISTANT NEW RESIDENTIAL BUILDING CONSTRUCTION
CHAPTER B101 GENERAL
782 B101 GENERAL
B102 INTENT
B103 SCOPE
B104 COMPLIANCE
CHAPTER B201 DEFINITIONS
B201 GENERAL
B202 DEFINITIONS
783 CHAPTER B301 CONSTRUCTION REQUIREMENTS FOR PASSIVE RADON CONTROL
B301 GENERAL
B302 SUB-SLAB AND SOIL MEMBRANES
784 B303 FLOOR SLAB-ON-GRADE BUILDINGS
786 B304 SLAB-BELOW-GRADE CONSTRUCTION
B305 BUILDINGS WITH CRAWL SPACES
B306 BUILDINGS WITH COMBINATION FLOOR SYSTEMS
B307 SPACE CONDITIONING SYSTEMS
788 APPENDIX C FLORIDA STANDARD FOR MITIGATION OF RADON IN EXISTING BUILDINGS
INTRODUCTION
PRINCIPAL APPROACHES FOR RADON MITIGATION IN EXISTING BUILDINGS
FOREWORD
789 CHAPTER C1 ADMINISTRATION
CHAPTER C2 DEFINITIONS
790 CHAPTER C3 TESTING
CHAPTER C4 STRUCTURAL SEALING AND HVAC SYSTEM BALANCING
791 CHAPTER C5 ENGINEERED SYSTEMS
792 CHAPTER C6 SOIL DEPRESSURIZATION SYSTEMS
796 APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
797 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
798 SECTION D106 REFERENCED STANDARDS
800 APPENDIX E FLORIDA STANDARD FOR RADON-RESISTANT NEW COMMERCIAL CONSTRUCTION
CHAPTER E101 GENERAL
801 CHAPTER E201 DEFINITIONS
803 CHAPTER E301 CONSTRUCTION REQUIREMENTS FOR PASSIVE CONTROLS
808 CHAPTER E401 ACTIVE SOIL-DEPRESSURIZATION SYSTEMS
812 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
814 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
816 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
SECTION H104 IDENTIFICATION
817 SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
SECTION H109 GROUND SIGNS
818 SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
819 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
820 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
822 APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
SECTION J104 PERMIT APPLICATION AND SUBMITTALS
823 SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
824 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
825 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
826 APPENDIX K ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
827 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
828 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
830 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
832 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD
SECTION M101 TSUNAMI-GENERATED FLOOD HAZARD
SECTION M102 REFERENCED STANDARDS
834 INDEX
870 HELPFUL TOOLS FOR YOUR BUILDING CODE
871 ICC EVALUATION SERVICE
FL FloridaBuildingCode 2020