Shopping Cart

No products in the cart.

FL FloridaEnergy 2023 1stptg

$31.82

Florida Building Code – Energy Conservation, Eighth Edition

Published By Publication Date Number of Pages
FL 2023 221
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The Eight Edition (2023) update to the Florida Building Code: Energy Conservation is a fully integrated publication that updates the Seventh Edition 2020 Florida Building Code: Energy Conservation using the latest changes to the 2021International Energy Conservation Code

PDF Catalog

PDF Pages PDF Title
1 FLORIDA BUILDING CODE EIGHTH EDITION, 2023©
2 FLORIDA BUILDING CODE EIGHTH EDITION, 2023
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 COMMERCIAL PROVISIONS
TABLE OF CONTENTS
10 CHAPTER 1 [CE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION C101 SCOPE AND GENERAL REQUIREMENTS
11 SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION C103 CONSTRUCTION DOCUMENTS
12 SECTION C104 INSPECTIONS
13 SECTION C105 VALIDITY
SECTION C106 REFERENCED STANDARDS
SECTION C107 FEES RESERVED
SECTION C108 STOP WORK ORDER
SECTION C109 BOARD OF APPEALS RESERVED
14 CHAPTER 2 [CE] DEFINITIONS
SECTION C201 GENERAL
SECTION C202 GENERAL DEFINITIONS
24 CHAPTER 3 [CE] GENERAL REQUIREMENTS
SECTION C301 CLIMATE ZONES
SECTION C302 DESIGN CONDITIONS
SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT
TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY COUNTY
25 TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
26 TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE C303.1.3(3) DEFAULT WINDOW, GLASS DOOR AND SKYLIGHT SHGC AND VT
SECTION C304 MATERIALS TESTING AND THERMAL PROPERTIES
28 CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY
SECTION C401 GENERAL
SECTION C402 BUILDING ENVELOPE REQUIREMENTS
TABLE C402.1.1.1 FENESTRATION THERMAL ENVELOPE MAXIMUM REQUIREMENTS
29 TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES
EQUATION 4-1
EQUATION 4-2
31 TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa
32 TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHODa, b
33 TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa
EQUATION 4-3
34 EQUATION 4-4
TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS
35 EQUATION 4-5
37 TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES
39 SECTION C403 BUILDING MECHANICAL SYSTEMS
EQUATION 4-6
EQUATION 4-7
40 TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc
41 TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc
42 TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc
43 TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPSc
44 TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPSc
45 TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS,PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
46 TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS,PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS
47 TABLE C403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS
48 TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS
TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED
49 TABLE C403.2.3(7) WATER CHILLING PACKAGES—EFFICIENCY REQUIREMENTSb, c, e
50 TABLE C403.2.3(8) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS
51 TABLE C403.2.3(9) FLOOR-MOUNTED AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS
52 TABLE C403.2.3(9)— continued FLOOR-MOUNTED AIR CONDITIONERS AND CONDENSING UNITSSERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS
53 TABLE C403.2.3(10) HEAT TRANSFER EQUIPMENT
TABLE C403.2.3(11) ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS
TABLE C403.2.3(12) ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS
54 TABLE C403.2.3(12)–continued ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS
55 TABLE C403.2.3(14) ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE-PACKAGE AND REMOTE CONDENSER,WITHOUT ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTSb
56 TABLE C403.2.3(15) ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE-PACKAGE AND REMOTE CONDENSER, WITH ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTS
TABLE C403.2.3(16) ELECTRICALLY OPERATED WATER-SOURCE HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTSb
57 TABLE C403.2.3(17) CEILING-MOUNTED COMPUTER-ROOM AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS
58 TABLE C403.2.3(17)–continued CEILING-MOUNTED COMPUTER-ROOM AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS
61 TABLE C403.2.7(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year)
62 TABLE C403.2.7(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year)
TABLE C403.2.9.1 MINIMUM DUCT INSULATION R-VALUES, HEATING AND COOLING SUPPLY AND RETURN DUCTS
63 TABLE C403.2.9.2 DUCT SYSTEM CONSTRUCTION AND SEALING
64 TABLE C403.2.9.2—continued DUCT SYSTEM CONSTRUCTION AND SEALING
65 TABLE C403.2.9.2—continued DUCT SYSTEM CONSTRUCTION AND SEALING
67 TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c
68 TABLE C403.2.12.1(1) FAN POWER LIMITATION
TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT
69 TABLE C403.2.12.5 REQUIREMENTS FOR FAN CONTROL
70 TABLE C403.2.12.6 CEILING FAN EFFICIENCY REQUIREMENTSa
71 TABLE C403.2.12.7 LOW-CAPACITY VENTILATION FAN EFFICACYa
TABLE C403.2.14.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS AND REFRIGERATION
72 TABLE C403.2.14.1(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS AND REFRIGERATION
TABLE C403.2.14.2(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa
73 TABLE C403.2.14.2(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa
TABLE C403.2.14.2(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEMS EFFICIENCY REQUIREMENTS (CE126-16AM)
TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS
74 TABLE C403.3.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS
75 TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb
76 TABLE C403.4.2.5 BOILER TURNDOWN
78 TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY
79 SECTION C404 SERVICE WATER HEATING (MANDATORY)
80 TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
81 TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT
82 TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS
83 TABLE C404.5.2.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING
84 SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS
86 EQUATION 4-8
87 FIGURE C405.2.4.2(1) SIDELIT ZONE
FIGURE C405.2.4.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR
88 FIGURE C405.2.4.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR
89 FIGURE C405.2.4.3 TOPLIT ZONE
FIGURE C405.2.4.4 DAYLIGHT ZONES AT A MULTISTORY ATRIUM
90 EQUATION 4-9
91 TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD
92 TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
93 TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD
EQUATION 4-10
95 TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES
TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
96 TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
97 TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS
TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B,AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b
98 TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b
TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa
99 TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa
SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS
100 SECTION C407 TOTAL BUILDING PERFORMANCE
102 TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
103 TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
104 TABLE C407.5.1(2) HVAC SYSTEMS MAP
105 TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS
106 TABLE C407.5.1(4) NUMBER OF CHILLERS
TABLE C407.5.1(5) WATER CHILLER TYPES
SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING
110 CHAPTER 5 [CE] EXISTING BUILDINGS
SECTION C501 GENERAL
111 SECTION C502 ADDITIONS
SECTION C503 ALTERATIONS
112 SECTION C504 REPAIRS
SECTION C505 CHANGE OF OCCUPANCY OR USE
114 CHAPTER 6 [CE] REFERENCED STANDARDS
AABC
AAMA
ACCA
ADC
115 AHAM
AHRI
AMCA
116 ANSI
APSP (PHTA Standards)
ASABE
ASHRAE
117 ASME
ASTM
118 CRRC
CSA
CTI
DASMA
DOE
119 Florida Codes
HVI
IEEE
IES
120 ISO
NAIMA
NEBB
NEMA
NFPA
121 NFRC
SMACNA
SPRI
UL
US-FTC
122 WDMA
124 APPENDIX CA FORMS
125 COMMERCIAL COMPLIANCE CHECKLIST
126 APPENDIX CB SOLAR-READY ZONE—COMMERCIAL
SECTION CB101 SCOPE
SECTION CB102 GENERAL DEFINITION
SECTION CB103 SOLAR-READY ZONE
128 APPENDIX CC ELECTRIC VEHICLE CHARGING PROVISIONS FOR NEW COMMERCIAL CONSTRUCTION
SECTION CC101 SCOPE
SECTION CC102 DEFINITIONS
SECTION CC103 REQUIREMENTS FOR ELECTRIC VEHICLE CHARGING
TABLE CC103.2 EV READY SPACE AND EV CAPABLE SPACE REQUIREMENTS
130 APPENDIX CD BOARD OF APPEALS—COMMERCIAL
SECTION CD101 GENERAL
132 APPENDIX CE ZERO CODE RENEWABLE ENERGY STANDARD
SECTION CE101 GENERAL
SECTION CE102 DEFINITIONS
SECTION CE103 MINIMUM RENEWABLE ENERGY
EQUATION CE-1
133 TABLE CE103.1 ENERGY UTILIZATION INTENSITY FOR BUILDING TYPES AND CLIMATES (kBtu/ft² – yr)
TABLE CE103.2 DEFAULT OFF-SITE RENEWABLE ENERGY PROCUREMENT METHODS, CLASSES, AND COEFFICIENTS
134 EQUATION CE-2
136 INDEX
146 RESIDENTIAL PROVISIONS
TABLE OF CONTENTS
148 CHAPTER 1 [RE] SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION R101 SCOPE AND GENERAL REQUIREMENTS
TABLE R101.5.1 INDEX TO CODE COMPLIANCE FORMS
SECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT
149 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION R103 CONSTRUCTION DOCUMENTS
150 SECTION R104 INSPECTIONS
SECTION R105 VALIDITY
151 SECTION R106 NOTICE OF APPROVAL
SECTION R107 REFERENCED STANDARDS
SECTION R108 FEES RESERVED
SECTION R109 STOP WORK ORDER
SECTION R110 BOARD OF APPEALS RESERVED
152 CHAPTER 2 [RE] DEFINITIONS
SECTION R201 GENERAL
SECTION R202 GENERAL DEFINITIONS
158 CHAPTER 3 [RE] GENERAL REQUIREMENTS
SECTION R301 CLIMATE ZONES
TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY COUNTY
SECTION R302 DESIGN CONDITIONS
SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT
159 TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS
TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS
160 TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS
TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS
TABLE R303.1.3(3) DEFAULT WINDOW, GLASS DOOR AND SKYLIGHT SHGC AND VT
161 TABLE R303.2.1 INSULATION INSTALLATION STANDARDS
TABLE R303.2.1.1 R-VALUES OF COMPRESSED INSULATION
162 CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY
SECTION R401 GENERAL
SECTION R402 BUILDING THERMAL ENVELOPE
163 TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa
TABLE R402.1.4 EQUIVALENT U-FACTORSa
164 TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE)
167 TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa
168 SECTION R403 SYSTEMS
171 TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
173 SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS
SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE)
175 TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
176 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
177 TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS
178 TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa
179 FIGURE R405.7.1 ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS
180 TABLE R405.7.6 FAN SIZING TABLE
SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE
181 TABLE R406.4 MAXIMUM ENERGY RATING INDEX
184 CHAPTER 5 [RE] EXISTING BUILDINGS
SECTION R501 GENERAL
185 SECTION R502 ADDITIONS
SECTION R503 ALTERATIONS
186 SECTION R504 REPAIRS
SECTION R505 CHANGE OF OCCUPANCY OR USE
188 CHAPTER 6 [RE] REFERENCED STANDARDS
AAMA
ACCA
AHRI
ANSI
189 APSP (PHTA Standards)
ARDM
ASHRAE
ASTM
190 CRRC
CSA
DASMA
191 Florida Codes
FSEC
HVI
ICC
192 IEEE
ISO
NEMA
NFPA
NFRC
193 RESNET
SRCC
UL
US-FTC
WDMA
194 APPENDIX RA RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER R402.4 OR R405 CONDITIONS ≤ 5 ACH50
SECTION RA101 SCOPE
SECTION RA201 GENERAL DEFINITIONS
SECTION RA301 TESTING PROCEDURE
195 TABLE RA301.1(1) CAZ DEPRESSURIZATION LIMITS
TABLE RA301.1(2) ACCEPTABLE DRAFT TEST CORRECTION
TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION
196 APPENDIX RB SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO FAMILY DWELLINGS, MULTIPLE SINGLE-FAMILY DWELLINGS(TOWNHOUSES)
SECTION RB101 SCOPE
SECTION RB102 GENERAL DEFINITION
SECTION RB103 SOLAR-READY ZONE
198 APPENDIX RC CALCULATION OF END USE ENERGY LOADS
TABLE RC-1(1) COEFFICIENTS ‘a’ AND ‘b’
200 APPENDIX RD FORMS
DUCT LEAKAGE TEST REPORT
201 ENVELOPE LEAKAGE TEST REPORT
202 FORM R402—2023
203 FORM R402—continued EQUIPMENT REQUIREMENTS AND INSTALLED VALUES
204 FORM R402—continued
206 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
207 FORM R400—2023 DESUPERHEATER, HEAT RECOVERY UNIT (HRU) WATER HEATER EFFICIENCY CERTIFICATION TESTS CONDUCTED IN ACCORDANCE WITHAHRI STANDARD 470
208 APPENDIX RE BOARD OF APPEALS—RESIDENTIAL
SECTION RE101 GENERAL
210 APPENDIX RF ELECTRIC VEHICLE CHARGING PROVISIONS FOR ONE AND TWO-FAMILY DWELLINGS AND TOWNHOUSES
SECTION RF101 SCOPE
SECTION RF102 DEFINITIONS
SECTION RF103 REQUIREMENTS FOR ELECTRIC VEHICLE CHARGING
212 INDEX
218 2018 ESSENTIALS GUIDES FOR IGCC AND IECC
219 ICC DIGITAL CODES PREMIUM
220 ICC EVALUATION SERVICE®
221 GET THE NEW 2023 FLORIDA CODES: COMPLETE COLLECTION
FL FloridaEnergy 2023 1stptg
$31.82