Florida Building Code – Energy Conservation, Eighth Edition
Published By | Publication Date | Number of Pages |
FL | 2023 | 221 |
The Eight Edition (2023) update to the Florida Building Code: Energy Conservation is a fully integrated publication that updates the Seventh Edition 2020 Florida Building Code: Energy Conservation using the latest changes to the 2021International Energy Conservation Code
PDF Catalog
PDF Pages | PDF Title |
---|---|
1 | FLORIDA BUILDING CODE EIGHTH EDITION, 2023© |
2 | FLORIDA BUILDING CODE EIGHTH EDITION, 2023 |
3 | COPYRIGHT |
4 | PREFACE |
6 | TABLE OF CONTENTS |
8 | COMMERCIAL PROVISIONS TABLE OF CONTENTS |
10 | CHAPTER 1 [CE] SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION C101 SCOPE AND GENERAL REQUIREMENTS |
11 | SECTION C102 ALTERNATE MATERIALS—METHOD OF CONSTRUCTION, DESIGNOR INSULATING SYSTEMS PART 2—ADMINISTRATION AND ENFORCEMENT SECTION C103 CONSTRUCTION DOCUMENTS |
12 | SECTION C104 INSPECTIONS |
13 | SECTION C105 VALIDITY SECTION C106 REFERENCED STANDARDS SECTION C107 FEES RESERVED SECTION C108 STOP WORK ORDER SECTION C109 BOARD OF APPEALS RESERVED |
14 | CHAPTER 2 [CE] DEFINITIONS SECTION C201 GENERAL SECTION C202 GENERAL DEFINITIONS |
24 | CHAPTER 3 [CE] GENERAL REQUIREMENTS SECTION C301 CLIMATE ZONES SECTION C302 DESIGN CONDITIONS SECTION C303 MATERIALS, SYSTEMS AND EQUIPMENT TABLE C301.1 CLIMATE ZONES, MOISTURE REGIMES, AND WARM-HUMID DESIGNATIONS BY COUNTY |
25 | TABLE C301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS TABLE C301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
26 | TABLE C303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS TABLE C303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS TABLE C303.1.3(3) DEFAULT WINDOW, GLASS DOOR AND SKYLIGHT SHGC AND VT SECTION C304 MATERIALS TESTING AND THERMAL PROPERTIES |
28 | CHAPTER 4 [CE] COMMERCIAL ENERGY EFFICIENCY SECTION C401 GENERAL SECTION C402 BUILDING ENVELOPE REQUIREMENTS TABLE C402.1.1.1 FENESTRATION THERMAL ENVELOPE MAXIMUM REQUIREMENTS |
29 | TABLE C402.1.4.1 EFFECTIVE R-VALUES FOR STEEL STUD WALL ASSEMBLIES EQUATION 4-1 EQUATION 4-2 |
31 | TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHODa |
32 | TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR METHODa, b |
33 | TABLE C402.3 MINIMUM ROOF REFLECTANCE AND EMITTANCE OPTIONSa EQUATION 4-3 |
34 | EQUATION 4-4 TABLE C402.4 BUILDING ENVELOPE FENESTRATION MAXIMUM U-FACTOR AND SHGC REQUIREMENTS |
35 | EQUATION 4-5 |
37 | TABLE C402.5.2 MAXIMUM AIR LEAKAGE RATE FOR FENESTRATION ASSEMBLIES |
39 | SECTION C403 BUILDING MECHANICAL SYSTEMS EQUATION 4-6 EQUATION 4-7 |
40 | TABLE C403.2.3(1) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc |
41 | TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc |
42 | TABLE C403.2.3(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AIR CONDITIONERS AND CONDENSING UNITSc |
43 | TABLE C403.2.3(2) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPSc |
44 | TABLE C403.2.3(2)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED UNITARY AND APPLIED HEAT PUMPSc |
45 | TABLE C403.2.3(3) MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS,PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
46 | TABLE C403.2.3(3)—continued MINIMUM EFFICIENCY REQUIREMENTS: ELECTRICALLY OPERATED PACKAGED TERMINAL AIR CONDITIONERS,PACKAGED TERMINAL HEAT PUMPS, SINGLE-PACKAGE VERTICAL AIR CONDITIONERS,SINGLE-PACKAGE VERTICAL HEAT PUMPS, ROOM AIR CONDITIONERS AND ROOM AIR-CONDITIONER HEAT PUMPS |
47 | TABLE C403.2.3(4) WARM AIR FURNACES AND COMBINATION WARM AIR FURNACES/AIR-CONDITIONING UNITS, WARM AIR DUCT FURNACES AND UNIT HEATERS, MINIMUM EFFICIENCY REQUIREMENTS |
48 | TABLE C403.2.3(5) MINIMUM EFFICIENCY REQUIREMENTS: GAS- AND OIL-FIRED BOILERS TABLE C403.2.3(6) MINIMUM EFFICIENCY REQUIREMENTS: CONDENSING UNITS, ELECTRICALLY OPERATED |
49 | TABLE C403.2.3(7) WATER CHILLING PACKAGES—EFFICIENCY REQUIREMENTSb, c, e |
50 | TABLE C403.2.3(8) PERFORMANCE REQUIREMENTS FOR HEAT REJECTION EQUIPMENT—MINIMUM EFFICIENCY REQUIREMENTS |
51 | TABLE C403.2.3(9) FLOOR-MOUNTED AIR CONDITIONERS AND CONDENSING UNITS SERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS |
52 | TABLE C403.2.3(9)— continued FLOOR-MOUNTED AIR CONDITIONERS AND CONDENSING UNITSSERVING COMPUTER ROOMS—MINIMUM EFFICIENCY REQUIREMENTS |
53 | TABLE C403.2.3(10) HEAT TRANSFER EQUIPMENT TABLE C403.2.3(11) ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW MULTI-SPLIT AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS TABLE C403.2.3(12) ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
54 | TABLE C403.2.3(12)–continued ELECTRICALLY OPERATED VARIABLE REFRIGERANT FLOW AND APPLIED HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTS |
55 | TABLE C403.2.3(14) ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE-PACKAGE AND REMOTE CONDENSER,WITHOUT ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTSb |
56 | TABLE C403.2.3(15) ELECTRICALLY OPERATED DX-DOAS UNITS, SINGLE-PACKAGE AND REMOTE CONDENSER, WITH ENERGY RECOVERY—MINIMUM EFFICIENCY REQUIREMENTS TABLE C403.2.3(16) ELECTRICALLY OPERATED WATER-SOURCE HEAT PUMPS—MINIMUM EFFICIENCY REQUIREMENTSb |
57 | TABLE C403.2.3(17) CEILING-MOUNTED COMPUTER-ROOM AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS |
58 | TABLE C403.2.3(17)–continued CEILING-MOUNTED COMPUTER-ROOM AIR CONDITIONERS—MINIMUM EFFICIENCY REQUIREMENTS |
61 | TABLE C403.2.7(1) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating less than 8,000 hours per year) |
62 | TABLE C403.2.7(2) ENERGY RECOVERY REQUIREMENT (Ventilation systems operating not less than 8,000 hours per year) TABLE C403.2.9.1 MINIMUM DUCT INSULATION R-VALUES, HEATING AND COOLING SUPPLY AND RETURN DUCTS |
63 | TABLE C403.2.9.2 DUCT SYSTEM CONSTRUCTION AND SEALING |
64 | TABLE C403.2.9.2—continued DUCT SYSTEM CONSTRUCTION AND SEALING |
65 | TABLE C403.2.9.2—continued DUCT SYSTEM CONSTRUCTION AND SEALING |
67 | TABLE C403.2.10 MINIMUM PIPE INSULATION THICKNESS (in inches)a, c |
68 | TABLE C403.2.12.1(1) FAN POWER LIMITATION TABLE C403.2.12.1(2) FAN POWER LIMITATION PRESSURE DROP ADJUSTMENT |
69 | TABLE C403.2.12.5 REQUIREMENTS FOR FAN CONTROL |
70 | TABLE C403.2.12.6 CEILING FAN EFFICIENCY REQUIREMENTSa |
71 | TABLE C403.2.12.7 LOW-CAPACITY VENTILATION FAN EFFICACYa TABLE C403.2.14.1(1) MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS AND REFRIGERATION |
72 | TABLE C403.2.14.1(1)—continued MINIMUM EFFICIENCY REQUIREMENTS: COMMERCIAL REFRIGERATORS AND FREEZERS AND REFRIGERATION TABLE C403.2.14.2(1) WALK-IN COOLER AND FREEZER DISPLAY DOOR EFFICIENCY REQUIREMENTSa |
73 | TABLE C403.2.14.2(2) WALK-IN COOLER AND FREEZER NONDISPLAY DOOR EFFICIENCY REQUIREMENTSa TABLE C403.2.14.2(3) WALK-IN COOLER AND FREEZER REFRIGERATION SYSTEMS EFFICIENCY REQUIREMENTS (CE126-16AM) TABLE C403.3(1) MINIMUM CHILLED-WATER SYSTEM COOLING CAPACITY FOR DETERMINING ECONOMIZER COOLING REQUIREMENTS |
74 | TABLE C403.3.1 DX COOLING STAGE REQUIREMENTS FOR MODULATING AIRFLOW UNITS |
75 | TABLE C403.3.3.3 HIGH-LIMIT SHUTOFF CONTROL SETTING FOR AIR ECONOMIZERSb |
76 | TABLE C403.4.2.5 BOILER TURNDOWN |
78 | TABLE C403.4.6 MAXIMUM HOT GAS BYPASS CAPACITY |
79 | SECTION C404 SERVICE WATER HEATING (MANDATORY) |
80 | TABLE C404.2 MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
81 | TABLE C404.2—continued MINIMUM PERFORMANCE OF WATER-HEATING EQUIPMENT |
82 | TABLE C404.5.1 PIPING VOLUME AND MAXIMUM PIPING LENGTHS |
83 | TABLE C404.5.2.1 INTERNAL VOLUME OF VARIOUS WATER DISTRIBUTION TUBING |
84 | SECTION C405 ELECTRICAL POWER AND LIGHTING SYSTEMS |
86 | EQUATION 4-8 |
87 | FIGURE C405.2.4.2(1) SIDELIT ZONE FIGURE C405.2.4.2(2) DAYLIGHT ZONE UNDER A ROOFTOP MONITOR |
88 | FIGURE C405.2.4.2(3) DAYLIGHT ZONE UNDER A SLOPED ROOFTOP MONITOR |
89 | FIGURE C405.2.4.3 TOPLIT ZONE FIGURE C405.2.4.4 DAYLIGHT ZONES AT A MULTISTORY ATRIUM |
90 | EQUATION 4-9 |
91 | TABLE C405.3.2(1) INTERIOR LIGHTING POWER ALLOWANCES: BUILDING AREA METHOD |
92 | TABLE C405.3.2(2) INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD |
93 | TABLE C405.3.2(2)—continued INTERIOR LIGHTING POWER ALLOWANCES: SPACE-BY-SPACE METHOD EQUATION 4-10 |
95 | TABLE C405.4.2(1) EXTERIOR LIGHTING ZONES TABLE C405.4.2(2) LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
96 | TABLE C405.4.2(3) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS |
97 | TABLE C405.6 MINIMUM NOMINAL EFFICIENCY LEVELS FOR 10 CFR 431 LOW-VOLTAGE DRY-TYPE DISTRIBUTION TRANSFORMERS TABLE C405.7(1) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN A, NEMA DESIGN B,AND IEC DESIGN N MOTORS (EXCLUDING FIRE PUMP) ELECTRIC MOTORS AT 60 HZa, b |
98 | TABLE C405.7(2) MINIMUM NOMINAL FULL-LOAD EFFICIENCY FOR NEMA DESIGN C AND IEC DESIGN H MOTORS AT 60 HZa, b TABLE C405.7(3) MINIMUM AVERAGE FULL-LOAD EFFICIENCY POLYPHASE SMALL ELECTRIC MOTORSa |
99 | TABLE C405.7(4) MINIMUM AVERAGE FULL-LOAD EFFICIENCY FOR CAPACITOR-START CAPACITOR-RUN AND CAPACITOR-START INDUCTION-RUN SMALL ELECTRIC MOTORSa SECTION C406 ADDITIONAL EFFICIENCY PACKAGE OPTIONS |
100 | SECTION C407 TOTAL BUILDING PERFORMANCE |
102 | TABLE C407.5.1(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
103 | TABLE C407.5.1(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
104 | TABLE C407.5.1(2) HVAC SYSTEMS MAP |
105 | TABLE C407.5.1(3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS |
106 | TABLE C407.5.1(4) NUMBER OF CHILLERS TABLE C407.5.1(5) WATER CHILLER TYPES SECTION C408 MAINTENANCE INFORMATION AND SYSTEM COMMISSIONING |
110 | CHAPTER 5 [CE] EXISTING BUILDINGS SECTION C501 GENERAL |
111 | SECTION C502 ADDITIONS SECTION C503 ALTERATIONS |
112 | SECTION C504 REPAIRS SECTION C505 CHANGE OF OCCUPANCY OR USE |
114 | CHAPTER 6 [CE] REFERENCED STANDARDS AABC AAMA ACCA ADC |
115 | AHAM AHRI AMCA |
116 | ANSI APSP (PHTA Standards) ASABE ASHRAE |
117 | ASME ASTM |
118 | CRRC CSA CTI DASMA DOE |
119 | Florida Codes HVI IEEE IES |
120 | ISO NAIMA NEBB NEMA NFPA |
121 | NFRC SMACNA SPRI UL US-FTC |
122 | WDMA |
124 | APPENDIX CA FORMS |
125 | COMMERCIAL COMPLIANCE CHECKLIST |
126 | APPENDIX CB SOLAR-READY ZONE—COMMERCIAL SECTION CB101 SCOPE SECTION CB102 GENERAL DEFINITION SECTION CB103 SOLAR-READY ZONE |
128 | APPENDIX CC ELECTRIC VEHICLE CHARGING PROVISIONS FOR NEW COMMERCIAL CONSTRUCTION SECTION CC101 SCOPE SECTION CC102 DEFINITIONS SECTION CC103 REQUIREMENTS FOR ELECTRIC VEHICLE CHARGING TABLE CC103.2 EV READY SPACE AND EV CAPABLE SPACE REQUIREMENTS |
130 | APPENDIX CD BOARD OF APPEALS—COMMERCIAL SECTION CD101 GENERAL |
132 | APPENDIX CE ZERO CODE RENEWABLE ENERGY STANDARD SECTION CE101 GENERAL SECTION CE102 DEFINITIONS SECTION CE103 MINIMUM RENEWABLE ENERGY EQUATION CE-1 |
133 | TABLE CE103.1 ENERGY UTILIZATION INTENSITY FOR BUILDING TYPES AND CLIMATES (kBtu/ft² – yr) TABLE CE103.2 DEFAULT OFF-SITE RENEWABLE ENERGY PROCUREMENT METHODS, CLASSES, AND COEFFICIENTS |
134 | EQUATION CE-2 |
136 | INDEX |
146 | RESIDENTIAL PROVISIONS TABLE OF CONTENTS |
148 | CHAPTER 1 [RE] SCOPE AND ADMINISTRATION PART 1—SCOPE AND APPLICATION SECTION R101 SCOPE AND GENERAL REQUIREMENTS TABLE R101.5.1 INDEX TO CODE COMPLIANCE FORMS SECTION R102 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT |
149 | PART 2—ADMINISTRATION AND ENFORCEMENT SECTION R103 CONSTRUCTION DOCUMENTS |
150 | SECTION R104 INSPECTIONS SECTION R105 VALIDITY |
151 | SECTION R106 NOTICE OF APPROVAL SECTION R107 REFERENCED STANDARDS SECTION R108 FEES RESERVED SECTION R109 STOP WORK ORDER SECTION R110 BOARD OF APPEALS RESERVED |
152 | CHAPTER 2 [RE] DEFINITIONS SECTION R201 GENERAL SECTION R202 GENERAL DEFINITIONS |
158 | CHAPTER 3 [RE] GENERAL REQUIREMENTS SECTION R301 CLIMATE ZONES TABLE R301.1 CLIMATE ZONES, MOISTURE REGIMES AND WARM-HUMID DESIGNATIONS BY COUNTY SECTION R302 DESIGN CONDITIONS SECTION R303 MATERIALS, SYSTEMS AND EQUIPMENT |
159 | TABLE R301.3(1) INTERNATIONAL CLIMATE ZONE DEFINITIONS TABLE R301.3(2) INTERNATIONAL CLIMATE ZONE DEFINITIONS |
160 | TABLE R303.1.3(1) DEFAULT GLAZED FENESTRATION U-FACTORS TABLE R303.1.3(2) DEFAULT OPAQUE DOOR U-FACTORS TABLE R303.1.3(3) DEFAULT WINDOW, GLASS DOOR AND SKYLIGHT SHGC AND VT |
161 | TABLE R303.2.1 INSULATION INSTALLATION STANDARDS TABLE R303.2.1.1 R-VALUES OF COMPRESSED INSULATION |
162 | CHAPTER 4 [RE] RESIDENTIAL ENERGY EFFICIENCY SECTION R401 GENERAL SECTION R402 BUILDING THERMAL ENVELOPE |
163 | TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa TABLE R402.1.4 EQUIVALENT U-FACTORSa |
164 | TABLE R402.2.6 STEEL-FRAME CEILING, WALL AND FLOOR INSULATION (R-VALUE) |
167 | TABLE R402.4.1.1 AIR BARRIER AND INSULATION INSTALLATIONa |
168 | SECTION R403 SYSTEMS |
171 | TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY |
173 | SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS SECTION R405 SIMULATED PERFORMANCE ALTERNATIVE (PERFORMANCE) |
175 | TABLE R405.5.2(1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
176 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
177 | TABLE R405.5.2(1)—continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS |
178 | TABLE R405.5.2(2) DEFAULT DISTRIBUTION SYSTEM EFFICIENCIES FOR PROPOSED DESIGNSa |
179 | FIGURE R405.7.1 ACCEPTABLE ATTIC RADIANT BARRIER CONFIGURATIONS |
180 | TABLE R405.7.6 FAN SIZING TABLE SECTION R406 ENERGY RATING INDEX COMPLIANCE ALTERNATIVE |
181 | TABLE R406.4 MAXIMUM ENERGY RATING INDEX |
184 | CHAPTER 5 [RE] EXISTING BUILDINGS SECTION R501 GENERAL |
185 | SECTION R502 ADDITIONS SECTION R503 ALTERATIONS |
186 | SECTION R504 REPAIRS SECTION R505 CHANGE OF OCCUPANCY OR USE |
188 | CHAPTER 6 [RE] REFERENCED STANDARDS AAMA ACCA AHRI ANSI |
189 | APSP (PHTA Standards) ARDM ASHRAE ASTM |
190 | CRRC CSA DASMA |
191 | Florida Codes FSEC HVI ICC |
192 | IEEE ISO NEMA NFPA NFRC |
193 | RESNET SRCC UL US-FTC WDMA |
194 | APPENDIX RA RECOMMENDED PROCEDURE FOR WORST-CASE TESTING OF ATMOSPHERIC VENTING SYSTEMS UNDER R402.4 OR R405 CONDITIONS ≤ 5 ACH50 SECTION RA101 SCOPE SECTION RA201 GENERAL DEFINITIONS SECTION RA301 TESTING PROCEDURE |
195 | TABLE RA301.1(1) CAZ DEPRESSURIZATION LIMITS TABLE RA301.1(2) ACCEPTABLE DRAFT TEST CORRECTION TABLE RA301.1(3) ACCEPTABLE DRAFT TEST CORRECTION |
196 | APPENDIX RB SOLAR-READY PROVISIONS—DETACHED ONE- AND TWO FAMILY DWELLINGS, MULTIPLE SINGLE-FAMILY DWELLINGS(TOWNHOUSES) SECTION RB101 SCOPE SECTION RB102 GENERAL DEFINITION SECTION RB103 SOLAR-READY ZONE |
198 | APPENDIX RC CALCULATION OF END USE ENERGY LOADS TABLE RC-1(1) COEFFICIENTS ‘a’ AND ‘b’ |
200 | APPENDIX RD FORMS DUCT LEAKAGE TEST REPORT |
201 | ENVELOPE LEAKAGE TEST REPORT |
202 | FORM R402—2023 |
203 | FORM R402—continued EQUIPMENT REQUIREMENTS AND INSTALLED VALUES |
204 | FORM R402—continued |
206 | ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD |
207 | FORM R400—2023 DESUPERHEATER, HEAT RECOVERY UNIT (HRU) WATER HEATER EFFICIENCY CERTIFICATION TESTS CONDUCTED IN ACCORDANCE WITHAHRI STANDARD 470 |
208 | APPENDIX RE BOARD OF APPEALS—RESIDENTIAL SECTION RE101 GENERAL |
210 | APPENDIX RF ELECTRIC VEHICLE CHARGING PROVISIONS FOR ONE AND TWO-FAMILY DWELLINGS AND TOWNHOUSES SECTION RF101 SCOPE SECTION RF102 DEFINITIONS SECTION RF103 REQUIREMENTS FOR ELECTRIC VEHICLE CHARGING |
212 | INDEX |
218 | 2018 ESSENTIALS GUIDES FOR IGCC AND IECC |
219 | ICC DIGITAL CODES PREMIUM |
220 | ICC EVALUATION SERVICE® |
221 | GET THE NEW 2023 FLORIDA CODES: COMPLETE COLLECTION |