Shopping Cart

No products in the cart.

FL FloridaExistingBuildingCode 2020

$49.29

Florida Building Code – Existing Building, Seventh Edition

Published By Publication Date Number of Pages
FL 2020 227
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 7th Edition (2020) update to the Florida Building Code: Existing Building is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Existing Building using the latest changes to the 2018 International Existing Building Code® with customized amendments adopted statewide. Florida Building Code Administrative Chapter 1 is included. Chapter tabs are also included. Effective Date: December 31, 2020

PDF Catalog

PDF Pages PDF Title
1 FLORIDA BUILDING CODE – EXISTING BUILDING SEVENTH EDITION (2020)
2 FLORIDA BUILDING CODE – EXISTING BUILDING SEVENTH EDITION (2020) TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
10 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF CODE OFFICIAL
SECTION 105 PERMITS
SECTION 106 CONSTRUCTION DOCUMENTS
SECTION 107 TEMPORARY STRUCTURES AND USES
SECTION 108 FEES
SECTION 109 INSPECTIONS
11 SECTION 110 CERTIFICATE OF OCCUPANCY
SECTION 111 SERVICE UTILITIES
SECTION 112 BOARD OF APPEALS
SECTION 113 VIOLATIONS
SECTION 114 STOP WORK ORDER
SECTION 115 UNSAFE BUILDINGS AND EQUIPMENT
SECTION 116 EMERGENCY MEASURES
SECTION 117 DEMOLITION
12 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 GENERAL DEFINITIONS
16 CHAPTER 3 PROVISIONS FOR ALL COMPLIANCE METHODS
SECTION 301 ADMINISTRATION
17 [BS] TABLE 301.4.1 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH FULL SEISMIC FORCES
[BS] TABLE 301.4.2 PERFORMANCE OBJECTIVES FOR USE IN ASCE 41 FOR COMPLIANCE WITH REDUCED SEISMIC FORCES
SECTION 302 GENERAL PROVISIONS
20 CHAPTER 4 REPAIRS
SECTION 401 GENERAL
SECTION 402 BUILDING ELEMENTS AND MATERIALS
SECTION 403 FIRE PROTECTION
SECTION 404 MEANS OF EGRESS
SECTION 405 ACCESSIBILITY
SECTION 406 STRUCTURAL
21 SECTION 407 ELECTRICAL
22 SECTION 408 MECHANICAL
SECTION 409 PLUMBING
24 CHAPTER 5 PRESCRIPTIVE COMPLIANCE METHOD
SECTION 501 GENERAL
SECTION 502 ADDITIONS
25 SECTION 503 ALTERATIONS
27 SECTION 504 FIRE ESCAPES
SECTION 505 GLASS REPLACEMENT AND REPLACEMENT WINDOWS
28 SECTION 506 CHANGE OF OCCUPANCY
SECTION 507 HISTORIC BUILDINGS
29 SECTION 508 MOVED STRUCTURES
SECTION 509 ACCESSIBILITY FOR EXISTING BUILDINGS
SECTION 510 EXISTING ROOFING
SECTION 511 ENERGY CONSERVATION
30 CHAPTER 6 CLASSIFICATION OF WORK
SECTION 601 GENERAL
SECTION 602 ALTERATION—LEVEL 1
SECTION 603 ALTERATION—LEVEL 2
SECTION 604 ALTERATION—LEVEL 3
SECTION 605 CHANGE OF OCCUPANCY
SECTION 606 ADDITIONS
SECTION 607 HISTORIC BUILDINGS
SECTION 608 RELOCATED BUILDINGS
SECTION 609 RETROFITTING
32 CHAPTER 7 ALTERATIONS—LEVEL 1
SECTION 701 GENERAL
SECTION 702 BUILDING ELEMENTS AND MATERIALS
33 SECTION 703 FIRE PROTECTION
SECTION 704 MEANS OF EGRESS
SECTION 705 ACCESSIBILITY
SECTION 706 EXISTING ROOFING
35 TABLE 706.7.1.2 SUPPLEMENT FASTENERS AT PANEL EDGES AND INTERMEDIATE FRAMING
36 TABLE 706.8.1 REQUIRED UPLIFT CAPACITIES FOR ROOF-TO-WALL CONNECTIONSa, b (POUNDS PER LINEAR FOOT)
38 SECTION 707 STRUCTURAL
39 SECTION 708 ENERGY CONSERVATION
40 CHAPTER 8 ALTERATIONS—LEVEL 2
SECTION 801 GENERAL
SECTION 802 SPECIAL USE AND OCCUPANCY
SECTION 803 BUILDING ELEMENTS AND MATERIALS
42 SECTION 804 FIRE PROTECTION
44 SECTION 805 MEANS OF EGRESS
45 TABLE 805.3.1.1(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 805.3.1.1(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
48 SECTION 806 ACCESSIBILITY
SECTION 807 STRUCTURAL
SECTION 808 ELECTRICAL
49 SECTION 809 MECHANICAL
SECTION 810 PLUMBING
SECTION 811 ENERGY CONSERVATION
50 CHAPTER 9 ALTERATIONS—LEVEL 3
SECTION 901 GENERAL
SECTION 902 SPECIAL USE AND OCCUPANCY
SECTION 903 BUILDING ELEMENTS AND MATERIALS
SECTION 904 FIRE PROTECTION
51 SECTION 905 MEANS OF EGRESS
SECTION 906 ACCESSIBILITY
SECTION 907 STRUCTURAL
52 SECTION 908 ENERGY CONSERVATION
SECTION 909 PLUMBING
54 CHAPTER 10 CHANGE OF OCCUPANCY
SECTION 1001 GENERAL
SECTION 1002 SPECIAL USE AND OCCUPANCY
SECTION 1003 BUILDING ELEMENTS AND MATERIALS
SECTION 1004 FIRE PROTECTION
SECTION 1005 MEANS OF EGRESS
SECTION 1006 ACCESSIBILITY
SECTION 1007 STRUCTURAL
55 SECTION 1008 ELECTRICAL
SECTION 1009 MECHANICAL
56 SECTION 1010 PLUMBING
SECTION 1011 OTHER REQUIREMENTS
SECTION 1012 CHANGE OF OCCUPANCY CLASSIFICATION
57 TABLE 1012.4 MEANS OF EGRESS HAZARD CATEGORIES
TABLE 1012.5 HEIGHTS AND AREAS HAZARD CATEGORIES
58 TABLE 1012.6 EXPOSURE OF EXTERIOR WALLS HAZARD CATEGORIES
59 SECTION 1013 ENERGY CONSERVATION
60 CHAPTER 11 ADDITIONS
SECTION 1101 GENERAL
SECTION 1102 HEIGHTS AND AREAS
SECTION 1103 STRUCTURAL
61 SECTION 1104 SMOKE ALARMS IN OCCUPANCY GROUPS R AND I-1
SECTION 1105 ACCESSIBILITY
SECTION 1106 ENERGY CONSERVATION
SECTION 1107 PLUMBING
62 SECTION 1108 CARBON MONOXIDE PROTECTION
64 CHAPTER 12 HISTORIC BUILDINGS
SECTION 1201 GENERAL
SECTION 1202 DEFINITIONS
65 SECTION 1203 STANDARDS AND GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS
SECTION 1204 EQUIVALENCY
SECTION 1205 COMPLIANCE
SECTION 1206 INVESTIGATION AND EVALUATION
66 SECTION 1207 HISTORIC CUBAN TILE
68 CHAPTER 13 RELOCATED OR MOVED BUILDINGS
SECTION 1301 GENERAL
SECTION 1302 REQUIREMENTS
70 CHAPTER 14 PERFORMANCE COMPLIANCE METHODS
SECTION 1401 GENERAL
71 EQUATION 14-1
EQUATION 14-2
EQUATION 14-3
72 EQUATION 14-4
TABLE 1401.6.3 COMPARTMENTATION VALUES
TABLE 1401.6.4 SEPARATION VALUES
73 TABLE 1401.6.5 CORRIDOR WALL VALUES
TABLE 1401.6.6(1) VERTICAL OPENING PROTECTION VALUE
TABLE 1401.6.6(2) CONSTRUCTION-TYPE FACTOR
EQUATION 14-5
74 TABLE 1401.6.8 AUTOMATIC FIRE DETECTION VALUES
TABLE 1401.6.9 FIRE ALARM SYSTEM VALUES
TABLE 1401.6.10 SMOKE CONTROL VALUES
75 TABLE 1401.6.11 MEANS OF EGRESS VALUESa
TABLE 1401.6.12 DEAD-END VALUES
76 EQUATION 14-6
TABLE 1401.6.14 ELEVATOR CONTROL VALUES
TABLE 1401.6.15 MEANS-OF-EGRESS EMERGENCY LIGHTING VALUES
TABLE 1401.6.16 MIXED OCCUPANCY VALUESa
77 TABLE 1401.6.17 SPRINKLER SYSTEM VALUES
TABLE 1401.6.18 STANDPIPE SYSTEM VALUES
78 TABLE 1401.6.19 INCIDENTAL USE AREA VALUES
TABLE 1401.6.20 SMOKE COMPARTMENTATION VALUES
TABLE 1401.6.21.1 PATIENT ABILITY VALUES
TABLE 1401.6.21.2 PATIENT CONCENTRATION VALUES
79 TABLE 1401.6.21.3 ATTENDANT-TO-PATIENT RATIO VALUES
TABLE 1401.8 MANDATORY SAFETY SCORESa
TABLE 1401.9 EVALUATION FORMULASa
80 TABLE 1401.7 SUMMARY SHEET-BUILDING CODE
82 CHAPTER 15 CONSTRUCTION SAFEGUARDS
SECTION 1501 GENERAL
[BS] TABLE 1501.6 PROTECTION OF PEDESTRIANS
83 SECTION 1502 PROTECTION OF ADJOINING PROPERTY
SECTION 1503 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 1504 FIRE EXTINGUISHERS
84 SECTION 1505 MEANS OF EGRESS
SECTION 1506 STANDPIPE SYSTEMS
SECTION 1507 AUTOMATIC SPRINKLER SYSTEM
SECTION 1508 ACCESSIBILITY
SECTION 1509 WATER SUPPLY FOR FIRE PROTECTION
86 CHAPTER 16 REFERENCED STANDARDS
ACI
ASCE/SEI
ASHRAE
87 ASME
ASTM
Florida Codes
88 ICC
NFPA
90 CHAPTER 17 RETROFITTING
SECTION 1701 GENERAL
SECTION 1702 DEFINITIONS
91 SECTION 1703 MATERIALS
TABLE 1703.3 MATERIAL SPECIFICATIONS FOR RETROFITS
TABLE 1703.5 NAIL AND SCREW REQUIREMENTS
92 SECTION 1704 GENERAL REQUIREMENTS AND MEANS OF RETROFIT
FIGURE 1704.1 GENERAL MEANS OF GABLE END RETROFIT
93 TABLE 1704.1 RETROFIT CONFIGURATION AS A FUNCTION OF EXPOSURE CATEGORY, DESIGN WIND SPEED, AND STUD HEIGHT
94 SECTION 1705 ADDED STUDS
SECTION 1706 RETROFIT STUDS
95 FIGURE 1706.3 PLACEMENT OF RETROFIT STUDS
96 FIGURE 1706.4.2 NAIL PLATE FASTENING
98 FIGURE 1707.1(1) TRUSS GABLE END WALL WITH L-BENT STRAPS
99 FIGURE 1707.1(2) CONVENTIONALLY FRAME GABLE END WALL WITH L-BENT STRAPS
100 FIGURE 1707.1(3) TRUSS GABLE END WALL WITH U-BENT STRAPS
101 FIGURE 1707.1(4) CONVENTIONALLY FRAME GABLE END WALL WITH U-BENT STRAPS
102 SECTION 1707 LATERAL BRACES
103 FIGURE 1707.4.1 OMITTED LATERAL BRACE
104 FIGURE 1707.4.2 INTERRUPTED LATERAL BRACES
106 FIGURE 1708.1.1(1) L-BENT STRAP METHOD FOR CONFIGURATIONS A, B, AND C
107 SECTION 1708 ATTACHMENT OF LATERAL BRACES TO RETROFIT STUDS
FIGURE 1708.1.1(2) L-BENT STRAP METHOD FOR CONFIGURATION D
108 FIGURE 1708.1.2(1) U-BENT STRAP METHOD FOR CONFIGURATIONS A, B AND C
FIGURE 1708.1.2(2) U-BENT STRAP METHOD FOR CONFIGURATION D
109 SECTION 1709 CONNECTIONS TO WALL BELOW
112 APPENDIX A: GUIDELINES FOR THE SEISMIC RETROFIT OF EXISTING BUILDINGS
CHAPTER A1 SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS
SECTION A101 PURPOSE
SECTION A102 SCOPE
SECTION A103 DEFINITIONS
SECTION A104 SYMBOLS AND NOTATIONS
113 SECTION A105 GENERAL REQUIREMENTS
114 SECTION A106 MATERIALS REQUIREMENTS
115 EQUATION A1-1
EQUATION A1-2
EQUATION A1-3
116 SECTION A107 QUALITY CONTROL
117 SECTION A108 DESIGN STRENGTHS
EQUATION A1-4
EQUATION A1-5
EQUATION A1-6
118 SECTION A109 ANALYSIS AND DESIGN PROCEDURE
SECTION A110 GENERAL PROCEDURE
EQUATION A1-7
SECTION A111 SPECIAL PROCEDURE
EQUATION A1-8
119 EQUATION A1-9
EQUATION A1-10
EQUATION A1-11
EQUATION A1-12
EQUATION A1-13
EQUATION A1-14
EQUATION A1-15
EQUATION A1-16
EQUATION A1-17
120 EQUATION A1-18
EQUATION A1-19
SECTION A112 ANALYSIS AND DESIGN
EQUATION A1-20
EQUATION A1-21
EQUATION A1-22
EQUATION A1-23
EQUATION A1-24
EQUATION A1-25
SECTION A113 DETAILED SYSTEM DESIGN REQUIREMENTS
122 [BS] TABLE A1-A ELEMENTS REGULATED BY THIS CHAPTER
[BS] TABLE A1-B ALLOWABLE VALUE OF HEIGHT-TO-THICKNESS RATIO OF UNREINFORCED MASONRY WALLS
[BS] TABLE A1-C HORIZONTAL FORCE FACTOR, Cp
SECTION A114 WALLS OF UNBURNED CLAY, ADOBE OR STONE MASONRY
123 [BS] TABLE A1-D STRENGTH VALUES FOR EXISTING MATERIALS
124 [BS] TABLE A1-E STRENGTH VALUES OF NEW MATERIALS USED IN CONJUNCTION WITH EXISTING CONSTRUCTION
[BS] TABLE A1-F MAXIMUM ALLOWABLE HEIGHT-TO-THICKNESS RATIOS FOR PARAPETS
[BS] TABLE A1-G MAXIMUM HEIGHT-TO-THICKNESS RATIOS FOR ADOBE OR STONE WALLS
125 [BS] FIGURE A1-1 ACCEPTABLE DIAPHRAGM SPAN
126 [BS] FIGURE A1-2 ANALYSIS OF URM WALL IN-PLANE SHEAR FORCES
128 CHAPTER A2 EARTHQUAKE HAZARD REDUCTION IN EXISTING REINFORCED CONCRETE AND REINFORCED MASONRY WALL BUILDINGS WITH FLEXIBLE DIAPHRAGMS
SECTION A201 PURPOSE
SECTION A202 SCOPE
SECTION A203 DEFINITIONS
SECTION A204 SYMBOLS AND NOTATIONS
SECTION A205 GENERAL REQUIREMENTS
129 SECTION A206 ANALYSIS AND DESIGN
130 SECTION A207 MATERIALS OF CONSTRUCTION
132 CHAPTER A3 PRESCRIPTIVE PROVISIONS FOR SEISMIC STRENGTHENING OF CRIPPLE WALLS AND SILL PLATE ANCHORAGE OF LIGHT, WOOD-FRAME RESIDENTIAL BUILDINGS
SECTION A301 GENERAL
SECTION A302 DEFINITIONS
133 SECTION A303 STRUCTURAL WEAKNESSES
SECTION A304 STRENGTHENING REQUIREMENTS
136 [BS] TABLE A3-A SILL PLATE ANCHORAGE AND CRIPPLE WALL BRACING
[BS] TABLE A3-B SILL PLATE ANCHORAGE FOR VARIOUS LENGTHS OF SILL PLATEa
137 [BS] FIGURE A3-1 NEW REINFORCED CONCRETE FOUNDATION SYSTEM
138 [BS] FIGURE A3-2 NEW MASONRY CONCRETE FOUNDATION
139 [BS] FIGURE A3-3 SILL PLATE BOLTING TO EXISTING FOUNDATION
140 [BS] FIGURE A3-4A ALTERNATE SILL PLATE ANCHORING IN EXISTING FOUNDATION—WITHOUT CRIPPLE WALLS AND FLOOR FRAMING NOT PARALLEL TO FOUNDATIONS
141 [BS] FIGURE A3-4B ALTERNATE SILL PLATE ANCHOR TO EXISTING FOUNDATION WITHOUT CRIPPLE WALL AND FLOOR FRAMING PARALLEL TO FOUNDATIONS
[BS] FIGURE A3-4C SILL PLATE ANCHORING TO EXISTING FOUNDATION—ALTERNATE CONNECTION FOR BATTERED FOOTING
142 [BS] FIGURE A3-5 CRIPPLE WALL BRACING WITH NEW WOOD STRUCTURAL PANEL ON EXTERIOR FACE OF CRIPPLE STUDS
143 [BS] FIGURE A3-6 CRIPPLE WALL BRACING WITH WOOD STRUCTURAL PANEL ON INTERIOR FACE OF CRIPPLE STUDS
144 [BS] FIGURE A3-7 PARTIAL CRIPPLE STUD WALL ELEVATION
145 [BS] FIGURE A3-8A TYPICAL FLOOR TO CRIPPLE WALL CONNECTION (FLOOR JOISTS NOT PARALLEL TO FOUNDATIONS)
146 [BS] FIGURE A3-8B TYPICAL FLOOR TO CRIPPLE WALL CONNECTION (FLOOR JOISTS PARALLEL TO FOUNDATIONS)
147 [BS] FIGURE A3-8C TYPICAL FLOOR TO MUDSILL CONNECTIONS
148 [BS] FIGURE A3-9 ALTERNATE FLOOR FRAMING TO CRIPPLE WALL CONNECTION
149 [BS] FIGURE A3-10 FLOOR PLAN-CRIPPLE WALL BRACING LAYOUT
150 CHAPTER A4 EARTHQUAKE RISK REDUCTION IN WOOD-FRAME RESIDENTIAL BUILDINGS WITH SOFT, WEAK OR OPEN FRONT WALLS
SECTION A401 GENERAL
SECTION A402 DEFINITIONS
SECTION A403 ANALYSIS AND DESIGN
152 SECTION A404 PRESCRIPTIVE MEASURES FOR WEAK STORY
SECTION A405 MATERIALS OF CONSTRUCTION
153 SECTION A406 INFORMATION REQUIRED TO BE ON THE PLANS
SECTION A407 QUALITY CONTROL
154 CHAPTER A5 REFERENCED STANDARDS
ASCE/SEI
ASTM
ICC
156 APPENDIX B STANDARD FOR REHABILITATION
THE SECRETARY OF THE INTERIOR’S STANDARDS FOR REHABILITATION AND GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS
INTRODUCTION
157 THE SECRETARY OF THE INTERIOR’S STANDARDS FOR REHABILITATION
158 GUIDELINES FOR REHABILITATING HISTORIC BUILDINGS
161 BUILDING EXTERIOR
176 BUILDING INTERIOR
184 BUILDING SITE
187 DISTRICT/NEIGHBORHOOD
189 HEALTH AND SAFETY CODE REQUIREMENTS
190 ENERGY RETROFITTING
192 NEW ADDITIONS TO HISTORIC BUILDINGS
194 APPENDIX C REFER TO NFPA 914 CODEFOR FIRE PROTECTION OF HISTORIC STRUCTURES 2001 EDITION
196 CHAPTER C2 ROOF DECK FASTENING FOR HIGH-WIND AREAS
198 RESOURCE A GUIDELINES ON FIRE RATING OF ARCHAIC MATERIALS AND ASSEMBLIES
200 INDEX
204 FLORIDA BUILDING CODE – BUILDING SEVENTH EDITION (2020) CHAPTER 1
206 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
209 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
SECTION 105 PERMITS
215 SECTION 106 FLOOR AND ROOF DESIGN LOADS
216 SECTION 107 SUBMITTAL DOCUMENTS
220 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
224 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
225 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
SECTION 117 VARIANCES IN FLOOD HAZARD AREAS
226 HELPFUL TOOS FOR YOUR EXISTING BUILDING CODE
227 ICC PLAN REVIEW SERVICES
FL FloridaExistingBuildingCode 2020
$49.29