Florida Building Code – Fuel Gas, Seventh Edition

Published By Publication Date Number of Pages
FL 2020 201
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 7th Edition (2020) update to the Florida Building Code: Fuel Gas is a fully integrated publication that updates the 6th Edition 2017 Florida Building Code: Fuel Gas using the latest changes to the 2018 International Fuel Gas Code® with customized amendments adopted statewide. Florida Building Code Administrative Chapter 1 is included. Chapter tabs are also included. Effective Date: December 31, 2020

PDF Catalog

PDF Pages PDF Title
1 FLORIDA BUILDING CODE – FUEL GAS CODE SEVENTH EDITION (2020)
2 FLORIDA BUILDING CODE – FUEL GAS CODE SEVENTH EDITION (2020) TITLE PAGE
3 COPYRIGHT
4 PREFACE
6 TABLE OF CONTENTS
8 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 (IFGC) GENERAL
9 SECTION 102 (IFGC) APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 (IFGC) DEPARTMENT OF INSPECTION
SECTION 104 (IFGC)DUTIES AND POWERS OF THE CODE OFFICIAL
SECTION 105 (IFGC) APPROVAL
SECTION 106 (IFGC) PERMITS
SECTION 107 (IFGC) INSPECTIONS AND TESTING
SECTION 108 (IFGC) VIOLATIONS
SECTION 109 (IFGC) MEANS OF APPEAL
SECTION 110 (IFGC) TEMPORARY EQUIPMENT, SYSTEMS AND USES
10 CHAPTER 2 DEFINITIONS
SECTION 201 (IFGC) GENERAL
SECTION 202 (IFGC) GENERAL DEFINITIONS
18 CHAPTER 3 GENERAL REGULATIONS
SECTION 301 (IFGC) GENERAL
19 SECTION 302 (IFGC) STRUCTURAL SAFETY
SECTION 303 (IFGC) APPLIANCE LOCATION
20 SECTION 304 (IFGS) COMBUSTION, VENTILATION AND DILUTION AIR
EQUATION 3-1
21 EQUATION 3-2
FIGURE 304.5.3 ALL AIR FROM INSIDE THE BUILDING (see Section 304.5.3)
FIGURE 304.6.1(1) ALL AIR FROM OUTDOORS—INLET AIR FROM VENTILATED CRAWL SPACE AND OUTLET AIR TO VENTILATED ATTIC (see Section 304.6.1)
22 FIGURE 304.6.1(2) ALL AIR FROM OUTDOORS THROUGH VENTILATED ATTIC (see Section 304.6.1)
FIGURE 304.6.1(3) ALL AIR FROM OUTDOORS (see Section 304.6.1)
FIGURE 304.6.2 SINGLE COMBUSTION AIR OPENING, ALL AIR FROM THE OUTDOORS (see Section 304.6.2
23 SECTION 305 (IFGC) INSTALLATION
24 SECTION 306 (IFGC) ACCESS AND SERVICE SPACE
26 SECTION 307 (IFGC) CONDENSATE DISPOSAL
SECTION 308 (IFGS) CLEARANCE REDUCTION
27 TABLE 308.2 REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION
28 FIGURE 308.2(1) EXTENT OF PROTECTION NECESSARY TO REDUCE CLEARANCES FROM APPLIANCE OR VENT CONNECTIONS
FIGURE 308.2(2) WALL PROTECTOR CLEARANCE REDUCTION SYSTEM
FIGURE 308.2(3) MASONRY CLEARANCE REDUCTION SYSTEM
29 SECTION 309 (IFGC) ELECTRICAL
SECTION 310 (IFGS) ELECTRICAL BONDING
30 SECTION 311 CARBON MONOXIDE CONTROL SYSTEMS
32 CHAPTER 4 GAS PIPING INSTALLATIONS
SECTION 401 (IFGC) GENERAL
SECTION 402 (IFGS) PIPE SIZING
EQUATION 4-1
33 EQUATION 4-2
TABLE 402.4 Cr AND Y VALUES FOR NATURAL GAS AND UNDILUTED PROPANE AT STANDARD CONDITIONS
34 TABLE 402.4(1) SCHEDULE 40 METALLIC PIPE
35 TABLE 402.4(2) SCHEDULE 40 METALLIC PIPE
36 TABLE 402.4(3) SCHEDULE 40 METALLIC PIPE
37 TABLE 402.4(4) SCHEDULE 40 METALLIC PIPE
38 TABLE 402.4(5) SCHEDULE 40 METALLIC PIPE
39 TABLE 402.4(6) SCHEDULE 40 METALLIC PIPE
40 TABLE 402.4(7) SCHEDULE 40 METALLIC PIPE
41 TABLE 402.4(8) SEMIRIGID COPPER TUBING
42 TABLE 402.4(9) SEMIRIGID COPPER TUBING
43 TABLE 402.4(10) SEMIRIGID COPPER TUBING
44 TABLE 402.4(11) SEMIRIGID COPPER TUBING
45 TABLE 402.4(12) SEMIRIGID COPPER TUBING
46 TABLE 402.4(13) SEMIRIGID COPPER TUBING
47 TABLE 402.4(14) SEMIRIGID COPPER TUBING
48 TABLE 402.4(15) CORRUGATED STAINLESS STEEL TUBING (CSST)
49 TABLE 402.4(16) CORRUGATED STAINLESS STEEL TUBING (CSST)
50 TABLE 402.4(17) CORRUGATED STAINLESS STEEL TUBING (CSST)
51 TABLE 402.4(18) CORRUGATED STAINLESS STEEL TUBING (CSST)
52 TABLE 402.4(19) CORRUGATED STAINLESS STEEL TUBING (CSST)
53 TABLE 402.4(20) POLYETHYLENE PLASTIC PIPE
54 TABLE 402.4(21) POLYETHYLENE PLASTIC PIPE
55 TABLE 402.4(22) POLYETHYLENE PLASTIC PIPE
56 TABLE 402.4(23) POLYETHYLENE PLASTIC TUBING
TABLE 402.4(24) POLYETHYLENE PLASTIC TUBING
57 TABLE 402.4(25) SCHEDULE 40 METALLIC PIPE
58 TABLE 402.4(26) SCHEDULE 40 METALLIC PIPE
59 TABLE 402.4(27) SCHEDULE 40 METALLIC PIPE
60 TABLE 402.4(28) SCHEDULE 40 METALLIC PIPE
61 TABLE 402.4(29) SEMIRIGID COPPER TUBING
62 TABLE 402.4(30) SEMIRIGID COPPER TUBING
63 TABLE 402.4(31) SEMIRIGID COPPER TUBING
64 TABLE 402.4(32) CORRUGATED STAINLESS STEEL TUBING (CSST)
65 TABLE 402.4(33) CORRUGATED STAINLESS STEEL TUBING (CSST)
66 TABLE 402.4(34) CORRUGATED STAINLESS STEEL TUBING (CSST)
67 TABLE 402.4(35) POLYETHYLENE PLASTIC PIPE
68 TABLE 402.4(36) POLYETHYLENE PLASTIC PIPE
69 TABLE 402.4(37) POLYETHYLENE PLASTIC TUBING
70 SECTION 403 (IFGS) PIPING MATERIALS
71 TABLE 403.9.2 SPECIFICATIONS FOR THREADING METALLIC PIPE
72 SECTION 404 (IFGC) PIPING SYSTEM INSTALLATION
74 SECTION 405 (IFGS) PIPING BENDS AND CHANGES IN DIRECTION
75 SECTION 406 (IFGS) INSPECTION, TESTING AND PURGING
76 TABLE 406.7.1.1 SIZE AND LENGTH OF PIPING
77 SECTION 407 (IFGC) PIPING SUPPORT
SECTION 408 (IFGC) DRIPS AND SLOPED PIPING
78 FIGURE 408.4 METHOD OF INSTALLING A TEE FITTING SEDIMENT TRAP
SECTION 409 (IFGC) SHUTOFF VALVES
TABLE 409.1.1 MANUAL GAS VALVE STANDARDS
79 SECTION 410 (IFGC) FLOW CONTROLS
SECTION 411 (IFGC) APPLIANCE AND MANUFACTURED HOME CONNECTIONS
81 SECTION 412 (IFGC) LIQUEFIED PETROLEUM GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
82 SECTION 413 (IFGC) COMPRESSED NATURAL GAS MOTOR VEHICLE FUEL-DISPENSING FACILITIES
83 [F] TABLE 413.9.2.3 SEPARATION DISTANCE FOR ATMOSPHERIC VENTING OF CNG
84 SECTION 414 (IFGC) SUPPLEMENTAL AND STANDBY GAS SUPPLY
SECTION 415 (IFGS) PIPING SUPPORT INTERVALS
TABLE 415.1 SUPPORT OF PIPING
SECTION 416 (IFGS) OVERPRESSURE PROTECTION DEVICES
86 CHAPTER 5 CHIMNEYS AND VENTS
SECTION 501 (IFGC) GENERAL
87 SECTION 502 (IFGC) VENTS
88 SECTION 503 (IFGS) VENTING OF APPLIANCES
89 TABLE 503.4 TYPE OF VENTING SYSTEM TO BE USED
91 FIGURE 503.6.5 TERMINATION LOCATIONS FOR GAS VENTS WITH LISTED CAPS 12 INCHES OR LESS IN SIZE AT LEAST 8 FEET FROM A VERTICAL WALL
94 TABLE 503.8 THROUGH-THE-WALL, DIRECT-VENT TERMINATION CLEARANCES
TABLE 503.10.2.4 MINIMUM THICKNESS FOR GALVANIZED STEEL VENT CONNECTORS FOR LOW-HEAT APPLIANCES
95 TABLE 503.10.2.5 MINIMUM THICKNESS FOR STEEL VENT CONNECTORS FOR MEDIUM-HEAT APPLIANCES
96 TABLE 503.10.5 CLEARANCES FOR CONNECTORSa
97 SECTION 504 (IFGS) SIZING OF CATEGORY I APPLIANCE VENTING SYSTEMS
99 TABLE 504.3.2 MAXIMUM VENT CONNECTOR LENGTH
102 TABLE 504.2(1) TYPE B DOUBLE-WALL GAS VENT
103 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
104 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
105 TABLE 504.2(1)—continued TYPE B DOUBLE-WALL GAS VENT
106 TABLE 504.2(2) TYPE B DOUBLE-WALL GAS VENT
107 TABLE 504.2(2)-continued TYPE B DOUBLE-WALL GAS VENT
108 TABLE 504.2(3) MASONRY CHIMNEY
109 TABLE 504.2(3)—continued MASONRY CHIMNEY
110 TABLE 504.2(4) MASONRY CHIMNEY
111 TABLE 504.2(4)—continued MASONRY CHIMNEY
112 TABLE 504.2(5) SINGLE-WALL METAL PIPE OR TYPE B ASBESTOS CEMENT VENT
113 TABLE 504.2(6) EXTERIOR MASONRY CHIMNEY
114 TABLE 504.3(1) TYPE B DOUBLE-WALL VENT
115 TABLE 504.3(1)-continued TYPE B DOUBLE-WALL VENT
116 TABLE 504.3(2) TYPE B DOUBLE-WALL VENT
117 TABLE 504.3(3) MASONRY CHIMNEY
118 TABLE 504.3(4) MASONRY CHIMNEY
119 TABLE 504.3(5) SINGLE-WALL METAL PIPE OR TYPE ASBESTOS CEMENT VENT
120 TABLE 504.3(6a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(6b) EXTERIOR MASONRY CHIMNEY-continued
121 TABLE 504.3(7a) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY
TABLE 504.3(7b) EXTERIOR MASONRY CHIMNEY—continued
122 SECTION 505 (IFGC) DIRECT-VENT, INTEGRAL VENT, MECHANICAL VENT AND VENTILATION/EXHAUST HOOD VENTING
SECTION 506 (IFGC) FACTORY-BUILT CHIMNEYS
124 CHAPTER 6 SPECIFIC APPLIANCES
SECTION 601 (IFGC) GENERAL
SECTION 602 (IFGC) DECORATIVE APPLIANCES FOR INSTALLATION IN FIREPLACES
SECTION 603 (IFGC) LOG LIGHTERS
SECTION 604 (IFGC) VENTED GAS FIREPLACES (DECORATIVE APPLIANCES)
SECTION 605 (IFGC) VENTED GAS FIREPLACE HEATERS
SECTION 606 (IFGC) INCINERATORS AND CREMATORIES
SECTION 607 (IFGC) COMMERCIAL-INDUSTRIAL INCINERATORS
SECTION 608 (IFGC) VENTED WALL FURNACES
125 SECTION 609 (IFGC) FLOOR FURNACES
SECTION 610 (IFGC) DUCT FURNACES
SECTION 611 (IFGC) NONRECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
126 SECTION 612 (IFGC) RECIRCULATING DIRECT-FIRED INDUSTRIAL AIR HEATERS
SECTION 613 (IFGC) CLOTHES DRYERS
SECTION 614 (IFGC) CLOTHES DRYER EXHAUST
127 [M] TABLE 614.8.4.1 DRYER EXHAUST DUCT FITTING EQUIVALENT LENGTH
128 SECTION 615 (IFGC) SAUNA HEATERS
129 SECTION 616 (IFGC) ENGINE AND GAS TURBINE-POWERED EQUIPMENT
SECTION 617 (IFGC) POOL AND SPA HEATERS
SECTION 618 (IFGC) FORCED-AIR WARM-AIR FURNACES
130 SECTION 619 (IFGC) CONVERSION BURNERS
SECTION 620 (IFGC) UNIT HEATERS
SECTION 621 (IFGC) UNVENTED ROOM HEATERS
SECTION 622 (IFGC) VENTED ROOM HEATERS
SECTION 623 (IFGC) COOKING APPLIANCES
131 SECTION 624 (IFGC) WATER HEATERS
SECTION 625 (IFGC) REFRIGERATORS
SECTION 626 (IFGC) GAS-FIRED TOILETS
SECTION 627 (IFGC) AIR-CONDITIONING APPLIANCES
132 SECTION 628 (IFGC) ILLUMINATING APPLIANCES
133 SECTION 629 (IFGC) SMALL CERAMIC KILNS
SECTION 630 (IFGC) INFRARED RADIANT HEATERS
SECTION 631 (IFGC) BOILERS
SECTION 632 (IFGC) EQUIPMENT INSTALLED IN EXISTING UNLISTED BOILERS
SECTION 633 (IFGC) STATIONARY FUEL-CELL POWER SYSTEMS
SECTION 634 (IFGS) CHIMNEY DAMPER OPENING AREA
SECTION 635 (IFGC) GASEOUS HYDROGEN SYSTEMS
SECTION 636 (IFGC) OUTDOOR DECORATIVE APPLIANCES
134 TABLE 634.1 FREE OPENING AREA OF CHIMNEY DAMPER FOR VENTING FLUE GASES FROM UNLISTED DECORATIVE APPLIANCES FOR INSTALLATION IN VENTED FIREPLACES
136 CHAPTER 7 GASEOUS HYDROGEN SYSTEMS
SECTION 701 (IFGC) GENERAL
SECTION 702 (IFGC) GENERAL DEFINITIONS
SECTION 703 (IFGC) GENERAL REQUIREMENTS
137 SECTION 704 (IFGC) PIPING, USE AND HANDLING
138 SECTION 705 (IFGC) TESTING OF HYDROGEN PIPING SYSTEMS
139 SECTION 706 (IFGC) LOCATION OF GASEOUS HYDROGEN SYSTEMS
SECTION 707 (IFGC) OPERATION AND MAINTENANCE OF GASEOUS HYDROGEN SYSTEMS
SECTION 708 (IFGC) DESIGN OF LIQUEFIED HYDROGEN SYSTEMS ASSOCIATED WITH HYDROGEN VAPORIZATION OPERATIONS
140 IFGC/IFGS CHAPTER 8 REFERENCED STANDARDS
ANSI
141 ASME
ASTM
142 CSA
DOTn
Florida Codes
MSS
143 NFPA
UL
144 APPENDIX A (IFGS) SIZING AND CAPACITIES OF GAS PIPING
A.1 GENERAL PIPING CONSIDERATIONS
A.2 DESCRIPTION OF TABLES
145 TABLE A.2.2 EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
146 TABLE A.2.2—continued EQUIVALENT LENGTHS OF PIPE FITTINGS AND VALVES
147 TABLE A.2.4 MULTIPLIERS TO BE USED WITH TABLES 402.4(1) THROUGH 402.4(22) WHERE THE SPECIFIC GRAVITY OF THE GAS IS OTHER THAN 0.60
A.3 USE OF CAPACITY TABLES
149 TABLE A.3.4 THOUSANDS OF BTU/H (MBH) OF NATURAL GAS PER 100 FEET OF PIPE AT VARIOUS PRESSURE DROPS AND PIPE DIAMETERS
A.4 USE OF SIZING EQUATIONS
150 A.5 PIPE AND TUBE DIAMETERS
TABLE A.5.1 SCHEDULE 40 STEEL PIPE STANDARD SIZES
TABLE A.5.2 COPPER TUBE STANDARD SIZES
A.6 EXAMPLES OF PIPING SYSTEM DESIGN AND SIZING
151 FIGURE A.6.1 PIPING PLAN SHOWING A STEEL PIPING SYSTEM
FIGURE A.6.2 PIPING PLAN SHOWING A CSST SYSTEM
152 FIGURE A.6.3 PIPING PLAN SHOWING A COPPER TUBING SYSTEM
153 FIGURE A.6.4 PIPING PLAN SHOWING A MODIFICATION TO EXISTING PIPING SYSTEM
156 APPENDIX B (IFGS) SIZING OF VENTING SYSTEMS SERVING APPLIANCES EQUIPPED WITH DRAFT HOODS, CATEGORY I APPLIANCES AND APPLIANCES LISTED FOR USE WITH TYPE B VENTS
EXAMPLES USING SINGLE APPLIANCE VENTING TABLES
FIGURE B-1 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A TYPE B DOUBLE-WALL VENT
FIGURE B-2 TYPE B DOUBLE-WALL VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A SINGLE-WALL METAL VENT CONNECTOR
157 FIGURE B-3 VENT SYSTEM SERVING A SINGLE APPLIANCE WITH A MASONRY CHIMNEY OF TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-4 VENT SYSTEM SERVING A SINGLE APPLIANCE USING A MASONRY CHIMNEY AND A SINGLE-WALL METAL VENT CONNECTOR
FIGURE B-5 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING A SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-6 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND TYPE B DOUBLE-WALL VENT CONNECTOR
158 FIGURE B-7 VENT SYSTEM SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT AND SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-8 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH TYPE B DOUBLE-WALL VENT CONNECTOR
FIGURE B-9 MASONRY CHIMNEY SERVING TWO OR MORE APPLIANCES WITH SINGLE-WALL METAL VENT CONNECTORS
FIGURE B-10 ASBESTOS CEMENT TYPE B OR SINGLE-WALL METAL VENT SYSTEM SERVING TWO OR MORE DRAFT-HOOD-EQUIPPED APPLIANCES
159 FIGURE B-11 USE OF MANIFOLD COMMON VENT CONNECTOR
FIGURE B-12 USE OF OFFSET COMMON VENT
FIGURE B-13 MULTISTORY GAS VENT DESIGN PROCEDURE FOR EACH SEGMENT OF SYSTEM
FIGURE B-14 MULTISTORY VENT SYSTEMS
160 FIGURE B-15 (EXAMPLE 1) SINGLE DRAFT-HOOD-EQUIPPED APPLIANCE
FIGURE B-16 (EXAMPLE 2) SINGLE FAN-ASSISTED APPLIANCE
161 EXAMPLES USING COMMON VENTING TABLES
FIGURE B-17 (EXAMPLE 4) COMMON VENTING TWO DRAFT-HOOD-EQUIPPED APPLIANCES
FIGURE B-18 (EXAMPLE 5A) COMMON VENTING A DRAFT HOOD WITH A FAN-ASSISTED FURNACE INTO A TYPE B DOUBLE-WALL COMMON VENT
163 TABLE B-1 MASONRY CHIMNEY LINER DIMENSIONS WITH CIRCULAR EQUIVALENTSa
164 FIGURE B-19
166 APPENDIX C (IFGS) EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
APPENDIX C EXIT TERMINALS OF MECHANICAL DRAFT AND DIRECT-VENT VENTING SYSTEMS
168 APPENDIX D (IFGS) RECOMMENDED PROCEDURE FOR SAFETY INSPECTION OF AN EXISTING APPLIANCE INSTALLATION
D.1 GENERAL
D.2 OCCUPANT AND INSPECTOR SAFETY
169 D.3 GAS PIPING AND CONNECTION INSPECTIONS
D.4 INSPECTIONS TO BE PERFORMED WITH THE APPLIANCE NOT OPERATING
170 D.5 INSPECTOINS TO BE PERFORMED WITH THE APPLIANCE OPERATING
171 D.6 APPLIANCE-SPECIFIC INSPECTIONS
173 TABLE D.6 CO THRESHOLDS
174 INDEX
178 FLORIDA BUILDING CODE – BUILDING SEVENTH EDITION (2020) CHAPTER 1
180 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
SECTION 102 APPLICABILITY
183 PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
SECTION 105 PERMITS
189 SECTION 106 FLOOR AND ROOF DESIGN LOADS
190 SECTION 107 SUBMITTAL DOCUMENTS
194 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
SECTION 110 INSPECTIONS
198 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
199 SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
SECTION 117 VARIANCES IN FLOOD HAZARD AREAS
200 ICC LEARNING CENTER
201 ICC EVALUATION SERVICE
FL FloridaFuelGasCode 2020