FL OrangeCounty 3 N/A
$43.55
2011 Orange County Utilities Standards and Construction Specifications Manual
Published By | Publication Date | Number of Pages |
FL | N/A | 432 |
None
PDF Catalog
PDF Pages | PDF Title |
---|---|
5 | PREFACE |
7 | TABLE OF CONTENTS |
10 | TABLE OF TABLES and FIGURES |
11 | CHAPTER 1 GENERAL INFORMATION 1110: Introduction |
13 | 1111: Policies and Procedures |
17 | 1112: Definitions |
21 | 1113: Abbreviations |
27 | CHAPTER 2 GENERAL REQUIREMENTS AND DESIGN STANDARDS 2110: General Submittal Requirements |
29 | 2111: Project Documents and Submittals |
39 | 2112: Aerial Crossings |
41 | 2113: Directional Drilling |
43 | 2114: Jack and Bore |
45 | 2210: Water Main Design Standard |
55 | 2310: Gravity Main Design Standard |
63 | 2311: Wastewater Force Main Design Standard |
67 | 2410: Wastewater Pump Station Design Standard |
73 | 2510: Reclaimed Water Main Design Standard |
83 | CHAPTER 3 SPECIFICATIONS 3110: General Construction Requirements |
91 | 3111: Project Record Documents and Submittals |
101 | 3112: Site Preparations, Surface Removal, and Restoration |
103 | 3113: Excavations, Backfill, Compaction and Grading |
111 | 3114: Installation of Pipe |
119 | 3115: Directional Drilling |
127 | 3116: Jack and Bore |
131 | 3117: System Connections |
135 | 3118: Aerial Crossings |
137 | 3119: Coatings and Linings |
153 | 3210: Water Pipes, Valves, and Appurtenances |
161 | 3310: Wastewater Pipes, Valves, and Appurtenances |
169 | 3311: Wastewater Manholes |
173 | 3312: Collection System Bypass |
177 | 3410: Wastewater Pump Stations |
195 | 3411: Submersible Wastewater Pumps |
201 | 3412: Wastewater Pump Station Electrical Power & Control System |
225 | 3413: SCADA RTU Panel |
239 | 3510: Reclaimed water Pipes, Valves, and Appurtenances |
249 | 3511: Reclaimed Water Master Meter Electrical Control Systems |
255 | CHAPTER 4 FIELD TESTING AND INSPECTION PROCEDURES 4110: General Procedures |
257 | 4210: Testing and Inspection for Acceptance of Water Systems |
263 | 4310: Testing & Inspection for Acceptance of Wastewater Collection and Transmission Systems |
275 | 4410: Testing & Inspection for Acceptance of Pump Stations |
279 | 4510: Testing & Inspection for Acceptance of Reclaimed Water Systems |
285 | APPENDIX A STANDARD DRAWINGS GENERAL WATER DISTRIBUTION |
286 | WASTEWATER COLLECTION WASTEWATER PUMP STATIONS |
287 | RECLAIMED WATER DISTRIBUTION |
291 | FigGN |
292 | FigA101 |
293 | FigA102 |
294 | figA103 |
295 | FigA104-1 |
296 | FigA104-2 |
297 | figA105-1 |
298 | figA105-2 |
299 | FigA106 |
300 | FigA107 |
301 | FigA108 |
302 | FigA109 |
303 | FigA110 |
304 | FigA111 |
305 | FigA112 |
306 | FigA113 |
307 | FigA114 |
308 | FigA115-1 |
309 | FigA115-2 |
310 | FigA115-3 |
311 | FigA116 |
312 | FigA117 |
313 | FigA118 |
314 | FigA119 |
315 | FigA120 |
316 | FigA121-1 |
317 | FigA121-2 |
318 | FigA122-1 |
319 | FigA122-2 |
320 | FigA122-3 |
321 | FigA201 |
322 | FigA202 |
323 | FigA203 |
324 | FigA204 |
325 | FigA205 |
326 | FigA301 |
327 | FigA302 |
328 | FigA303 |
329 | FigA304 |
330 | FigA305 |
331 | FigA306 |
332 | figA307-1 |
333 | FigA307-2 |
334 | FigA401 |
335 | FigA402-1 |
336 | FigA402-2 |
337 | FigA402-3 |
338 | FigA402-4 |
339 | FigA402-5 |
340 | FigA402-6 |
341 | FigA403-1 |
342 | FigA403-2 |
343 | FigA403-3 |
344 | FigA403-4 |
345 | FigA403-5 |
346 | FigA403-6 |
347 | FigA404-1 |
348 | FigA404-2 |
349 | FigA404-3 |
350 | FigA404-4 |
351 | FigA404-5 |
352 | FigA405 |
353 | FigA406 |
354 | FigA407-1 |
355 | FigA407-2 |
356 | FigA408 |
357 | FigA409 |
358 | FigA412 |
359 | FigA413-1 |
360 | FigA413-2 |
361 | FigA414 |
362 | FigA415-1 |
363 | FigA415-2 |
364 | FigA416 |
365 | FigA417 |
366 | FigA418 |
367 | FigA419-1 |
368 | FigA419-2 |
369 | FigA419-3 |
370 | FigA419-4 |
371 | FigA420 |
372 | FigA501 |
373 | FigA502 |
374 | FigA503 |
375 | APPENDIX B FORMS Pump Station Start-Up |
385 | Water Main Disinfection Certification |
387 | System Connection |
389 | Pressure Test |
391 | Conveyance of Easement and Fee Simple Property |
393 | Bill of Sale (Water and Water Reclamation Systems) |
395 | Digital Data Submission |
397 | APPENDIX D PRODUCTS Approval Process for New Products |
401 | General Information |
403 | LIST OF APPROVED PRODUCTS – TRANSMISSION SYSTEMS |
412 | LIST OF APPROVED PRODUCTS – GRAVITY SYSTEMS |
415 | LIST OF APPROVED PRODUCTS – PUMP STATION SYSTEMS |
421 | APPENDIX E ERU/ERC FACTORS |