Shopping Cart

No products in the cart.

IAPMO UPC 2015 1stPrinting

$66.08

Uniform Plumbing Code, 2nd Printing

Published By Publication Date Number of Pages
IAPMO 2015 443
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The 2015 edition of the Uniform Plumbing Code (UPC©) represents the most current approaches in the plumbing field. It is the fifth edition developed under the ANSI Consensus process is designated as an American National Standards by the American National Standards Institute (ANSI). Contributions to the content of this code were made by every segment of the built industry, including such diverse interests as consumers, enforcing authorities, installers/maintainers, labor, manufacturers, research/standards/ testing laboratories, special experts and users. The UPC is designed to provide consumers with safe and sanitary plumbing systems while, at the same time, allowing latitude for innovation and new technologies. Key changes to the 2015 UPC include: New product standards for plumbing fixtures such as lavatories, showers, bathtubs and whirlpool bathtubs, bidets, urinals, drinking fountains, and sinks (Chapter 4). Lead-content provisions have been revised to address the minimum acceptable percentage lead content for pipes and fittings (Chapter 6) New provisions for residential fire sprinkler systems (Chapter 6) New requirements for the insulation of hot water piping (Chapter 6) New requirements for medical gas and vacuum systems based on NFPA 99 New testing and inspection provisions for nonpotable alternate water source systems (Chapter 15) New requirements for testing, inspection, and maintenance of nonpotable rainwater catchment systems (Chapter 16)

PDF Catalog

PDF Pages PDF Title
2 Preface
4 Important Notices and Disclaimers
Updating IAPMO Codes
5 Foreword
Origin and Development
6 Adoption
Revision Markings
7 Format of the Uniform Plumbing Code
13 Sample Legislation for Adoption of the Uniform Plumbing Code
14 Committee on Uniform Plumbing Code
15 Section Relocation
20 Table of Contents
Chapter 1 Administration
Chapter 2 Defintions
Chapter 3 General Regulations
21 Chapter 4 Plumbing Fixtures and Fixture Fittings
23 Chapter 5 Water Heaters
24 Chapter 6 Water Supply and Distribution
26 Chapter 7 Sanitary Drainage
27 Chapter 8 Indirect Wastes
28 Chapter 9 Vents
29 Chapter 10 Traps and Interceptors
30 Chapter 11 Storm Drainage
Chapter 12 Fuel Gas Piping
32 Chapter 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems
34 Chapter 14 Firestop Protection
Chapter 15 Alternate Water Sources for Nonpotable Applications
35 Chapter 16 Nonpotable Rainwater Catchment Systems
Chapter 17 Referenced Standards
Appendices Table of Contents
Appendix A Recommended Rules for Sizing the Water Supply System
Appendix B Explanatory Notes on Combination Waste and Vent Systems
36 Appendix C Alternate Plumbing Systems
Appendix D Sizing Storm Water Drainage Systems
Appendix E Manufactured/Mobile Home Parks and Recreational Vehicle Parks
Appendix F Firefighter Breathing Air Replenishment Systems
Appendix G Sizing of Venting Systems
Appendix H Private Sewage Disposal Systems
Appendix I Installation Standard
Appendix J Combination of Indoor and Outdoor Combustion and Ventilation Opening Design
Appendix K Potable Rainwater Catchment Systems
Appendix L Sustainable Practices
Index
38 Chapter 1 Administration
101.0 General.
101.1 Title.
101.2 Scope.
101.3 Purpose.
101.4 Unconstitutional.
101.5 Validity.
102.0 Applicability.
102.1 Conflicts Between Codes.
102.2 Existing Installations.
102.3 Maintenance.
102.4 Additions, Alterations, Renovations, or Repairs.
102.4.1 Building Sewers and Drains.
102.4.2 Openings.
102.5 Health and Safety.
102.6 Changes in Building Occupancy.
102.7 Moved Structures.
102.8 Appendices.
TABLE
39 103.0 Duties and Powers of the Authority Having Jurisdiction.
103.1 General.
103.2 Liability.
103.3 Applications and Permits.
103.3.1 Licensing.
103.4 Right of Entry.
104.0 Permits.
104.1 Permits Required.
104.2 Exempt Work.
104.3 Application for Permit.
40 104.3.1 Construction Documents.
104.3.2 Plan Review Fees.
104.3.3 Time Limitation of Application.
104.4 Permit Issuance.
104.4.1 Approved Plans or Construction Documents.
104.4.2 Validity of Permit.
104.4.3 Expiration.
104.4.4 Extensions.
41 104.4.5 Suspension or Revocation.
104.4.6 Retention of Plans.
104.5 Fees.
104.5.1 Work Commencing Before Permit Issuance.
104.5.2 Investigation Fees.
104.5.3 Fee Refunds.
105.0 Inspections and Testing.
105.1 General.
105.2 Required Inspections.
105.2.1 Uncovering.
105.2.1.1 Water Supply System.
105.2.1.2 Covering or Using.
105.2.2 Other Inspections.
42 105.2.3 Inspection Requests.
105.2.4 Advance Notice.
105.2.5 Responsibility.
105.2.6 Reinspections.
105.3 Testing of Systems.
105.3.1 Defective Systems.
105.3.2 Retesting.
105.3.3 Approval.
105.4 Connection to Service Utilities.
106.0 Violations and Penalties.
106.1 General.
106.2 Notices of Correction or Violation.
106.3 Penalties.
43 106.4 Stop Orders.
106.5 Authority to Disconnect Utilities in Emergencies.
106.6 Authority to Condemn.
107.0 Board of Appeals.
107.1 General.
107.2 Limitations of Authority.
44 Table 104.5 Plumbing Permit Fees
46 Chapter 2 Defintions
201.0 General.
201.1 Applicability.
202.0 Definition of Terms.
202.1 General.
203.0 – A –
204.0 – B –
47 205.0 – C –
48 206.0 – D –
49 207.0 – E –
208.0 – F –
50 209.0 – G –
210.0 – H –
51 211.0 – I –
212.0 – J –
213.0 – K –
214.0 – L –
52 215.0 – M –
53 216.0 – N –
217.0 – O –
218.0 – P –
54 219.0 – Q –
220.0 – R –
55 221.0 – S –
222.0 – T –
56 223.0 – U –
224.0 – V –
225.0 – W –
57 226.0 – X –
227.0 – Y –
228.0 – Z –
58 Chapter 3 General Regulations
301.0 General.
301.1 Applicability.
301.2 Minimum Standards.
301.2.1 Marking.
301.2.2 Standards.
301.2.3 Plastic Pipe, Plastic Pipe Fittings, and Components.
301.2.4 Cast-Iron Soil Pipe and Fittings.
301.2.5 Existing Buildings.
301.3 Alternate Materials and Methods of Construction Equivalency.
301.3.1 Testing.
301.3.1.1 Tests.
301.3.1.2 Request by Authority Having Jurisdiction.
301.4 Flood Hazard Areas.
TABLES
59 301.4.1 Coastal High Hazard Areas.
301.5 Alternative Engineered Design.
301.5.1 Permit Application.
301.5.2 Technical Data.
301.5.3 Design Documents.
301.5.4 Design Approval.
301.5.5 Design Review.
301.5.6 Inspection and Testing.
302.0 Iron Pipe Size (IPS) Pipe.
302.1 General.
303.0 Disposal of Liquid Waste.
303.1 General.
304.0 Connections to Plumbing System Required.
304.1 General.
305.0 Damage to Drainage System or Public Sewer.
305.1 Unlawful Practices.
306.0 Industrial Wastes.
306.1 Detrimental Wastes.
306.2 Safe Discharge.
307.0 Location.
307.1 System.
307.2 Ownership.
308.0 Improper Location.
308.1 General.
60 309.0 Workmanship.
309.1 Engineering Practices.
309.2 Concealing Imperfections.
309.3 Burred Ends.
309.4 Installation Practices.
310.0 Prohibited Fittings and Practices.
310.1 Fittings.
310.2 Drainage and Vent Piping.
310.3 Waste Connection.
310.4 Use of Vent and Waste Pipes.
310.5 Obstruction of Flow.
310.6 Dissimilar Metals.
310.7 Direction of Flow.
310.8 Screwed Fittings.
311.0 Independent Systems.
311.1 General.
312.0 Protection of Piping, Materials, and Structures.
312.1 General.
312.2 Installation.
312.3 Building Sewer and Drainage Piping.
312.4 Corrosion, Erosion, and Mechanical Damage.
312.5 Protectively Coated Pipe.
312.6 Freezing Protection.
312.7 Fire-Resistant Construction.
312.8 Waterproofing of Openings.
61 312.9 Steel Nail Plates.
312.10 Sleeves.
312.10.1 Building Loads.
312.10.2 Exterior Walls.
312.10.3 Firewalls.
312.11 Structural Members.
312.12 Rodentproofing.
312.12.1 Meter Boxes.
312.12.2 Metal Collars.
312.12.3 Tub Waste Openings.
312.13 Exposed ABS Piping.
312.14 Exposed PVC Piping.
313.0 Hangers and Supports.
313.1 General.
313.2 Material.
313.3 Suspended Piping.
313.4 Alignment.
313.5 Underground Installation.
313.6 Hanger Rod Sizes.
313.7 Gas Piping.
314.0 Trenching, Excavation, and Backfill.
314.1 Trenches.
314.2 Tunneling and Driving.
Table 313.6 Hanger Rod Sizes
62 314.3 Open Trenches.
314.4 Excavations.
314.4.1 Installation of Thermoplastic Pipe and Fittings.
315.0 Joints and Connections.
315.1 Unions.
315.2 Prohibited Joints and Connections.
316.0 Increasers and Reducers.
316.1 General.
317.0 Food-Handling Establishments.
317.1 General.
318.0 Test Gauges.
318.1 General.
318.2 Pressure Tests (10 psi or less).
318.3 Pressure Tests (greater than 10 psi to 100 psi).
318.4 Pressure Tests (exceeding 100 psi).
318.5 Pressure Range.
319.0 Medical Gas and Vacuum Systems.
319.1 General.
320.0 Rehabilitation of Piping Systems.
320.1 General.
63 Table 313.3 Hangers and Supports
64 Chapter 4 Plumbing Fixtures and Fixture Fittings
401.0 General.
401.1 Applicability.
401.2 Quality of Fixtures.
402.0 Installation.
402.1 Cleaning.
402.2 Joints.
402.3 Securing Fixtures.
402.4 Wall-Hung Fixtures.
402.5 Setting.
402.6 Flanged Fixture Connections.
402.6.1 Closet Rings (Closet Flanges).
402.6.2 Securing Closet Flanges.
402.6.3 Securing Floor-Mounted, Back-Outlet Water Closet Bowls.
402.7 Supply Fittings.
402.8 Installation.
TABLE
65 402.9 Design and Installation of Plumbing Fixtures.
402.10 Slip Joint Connections.
402.11 Future Fixtures.
403.0 Accessible Plumbing Facilities.
403.1 General.
403.2 Fixtures and Fixture Fittings for Persons with Disabilities.
403.3 Exposed Pipes and Surfaces.
404.0 Overflows.
404.1 General.
405.0 Prohibited Fixtures.
405.1 Prohibited Water Closets.
405.2 Prohibited Urinals.
405.3 Miscellaneous Fixtures.
406.0 Special Fixtures and Specialties.
406.1 Water and Waste Connections.
406.2 Special Use Sinks.
406.3 Special Use Fixtures.
406.4 Zinc Alloy Components.
407.0 Lavatories.
407.1 Application.
407.2 Water Consumption.
407.2.1 Maximum Flow Rate.
407.2.2 Metering Faucets.
407.3 Limitation of Hot Water Temperature for Public Lavatories.
66 407.4 Transient Public Lavatories.
407.5 Waste Outlet.
407.6 Overflow.
408.0 Showers.
408.1 Application.
408.2 Water Consumption.
408.3 Individual Shower and Tub-Shower Combination Control Valves.
408.4 Waste Outlet.
408.5 Finished Curb or Threshold.
408.6 Shower Compartments.
408.7 Lining for Showers and Receptors.
67 408.7.1 PVC Sheets.
408.7.2 Chlorinated Polyethylene (CPE) Sheets.
408.7.3 Sheet Lead.
408.7.4 Sheet Copper.
408.7.5 Tests for Shower Receptors.
408.8 Public Shower Floors.
408.9 Location of Valves and Heads.
408.10 Water Supply Riser.
409.0 Bathtubs and Whirlpool Bathtubs.
409.1 Application.
409.2 Waste Outlet.
409.3 Overflow.
409.4 Limitation of Hot Water in Bathtubs and Whirlpool Bathtubs.
409.5 Backflow Protection.
409.6 Installation and Access.
68 409.6.1 Flexible PVC Hoses and Tubing.
410.0 Bidets.
410.1 Application.
410.2 Backflow Protection.
410.3 Limitation of Water Temperature in Bidets.
411.0 Water Closets.
411.1 Application.
411.2 Water Consumption.
411.2.1 Dual Flush Water Closets.
411.2.2 Flushometer Valve Activated Water Closets.
411.3 Water Closet Seats.
412.0 Urinals.
412.1 Application.
412.1.1 Nonwater Urinals.
412.2 Backflow Protection.
413.0 Flushing Devices.
413.1 Where Required.
413.2 Flushometer Valves.
413.3 Flush Tanks.
413.4 Water Supply for Flush Tanks.
69 413.5 Overflows in Flush Tanks.
414.0 Dishwashing Machines.
414.1 Application.
414.2 Backflow Protection.
414.3 Drainage Connection.
415.0 Drinking Fountains.
415.1 Application.
415.2 Drinking Fountain Alternatives.
415.3 Drainage Connection.
415.4 Location.
416.0 Emergency Eyewash and Shower Equipment.
416.1 Application.
416.2 Water Supply.
416.3 Installation.
416.4 Location.
416.5 Drain.
417.0 Faucets and Fixture Fittings.
417.1 Application.
417.2 Deck Mounted Bath/Shower Valves.
417.3 Handheld Showers.
417.4 Faucets and Fixture Fittings with Hose Connected Outlets.
417.5 Separate Controls for Hot and Cold Water.
418.0 Floor Drains.
418.1 Application.
418.2 Strainer.
70 418.3 Location of Floor Drains.
418.4 Food Storage Areas.
418.5 Floor Slope.
419.0 Food Waste Disposers.
419.1 Application.
419.2 Drainage Connection.
419.3 Water Supply.
420.0 Sinks.
420.1 Application.
420.2 Water Consumption.
420.3 Pre-Rinse Spray Valve.
420.4 Waste Outlet.
421.0 Floor Sinks.
421.1 Application.
421.2 Strainers.
422.0 Minimum Number of Required Fixtures.
422.1 Fixture Count.
422.1.1 Family or Assisted-Use Toilet and Bathing Facilities.
422.2 Separate Facilities.
71 422.2.1 Family or Assisted-Use Toilet Facilities.
422.3 Fixture Requirements for Special Occupancies.
422.4 Toilet Facilities Serving Employees and Customers.
422.4.1 Access to Toilet Facilities.
422.5 Toilet Facilities for Workers.
72 Table 422.1 Minimum Plumbing Facilities
76 Chapter 5 Water Heaters
501.0 General.
501.1 Applicability.
502.0 Permits.
502.1 General.
503.0 Inspection.
503.1 Inspection of Chimneys or Vents.
503.2 Final Water Heater Inspection.
504.0 Water Heater Requirements.
504.1 Location.
504.1.1 Self-Closing Doors.
504.1.2 Gasketing.
504.2 Vent.
504.3 Clearance.
504.3.1 Listed Water Heaters.
504.3.2 Unlisted Water Heaters.
TABLES
Table 501.1(1) First Hour Rating
FIGURES
77 504.4 Pressure-Limiting Devices.
504.5 Temperature-Limiting Devices.
504.6 Temperature, Pressure, and Vacuum Relief Devices.
505.0 Oil-Burning and Other Water Heaters.
505.1 Water Heaters.
505.2 Safety Devices.
505.3 Oil-Fired Water Heaters.
505.4 Indirect-Fired Water Heaters.
505.4.1 Single-Wall Heat Exchanger.
506.0 Air for Combustion and Ventilation.
506.1 General.
506.1.1 Other Types of Appliances.
506.1.2 Draft Hood and Regulators.
506.1.3 Makeup Air.
506.2 Indoor Combustion Air.
Table 501.1(2) Water Heaters
78 506.2.1 Standard Method.
506.2.2 Known Air Infiltration Rate Method.
506.3 Indoor Opening Size and Location.
506.4 Outdoor Combustion Air.
506.4.1 Two Permanent Openings Method.
506.4.2 One Permanent Opening Method.
Figure 506.3 Combustion Air from Adjacent Indoor Spaces through Indoor Combustion Air Openings
79 Figure 506.4(1) Combustion Air from Outdoors Inlet Air from Ventilated Crawl Space and Outlet Air to Ventilated Attic
Figure 506.4(2) Combustion Air from Outdoors through Ventilated Attic
Figure 506.4(3) Combustion Air from Outdoors through Horizontal Ducts
Figure 506.4.2 Combustion Air from Outdoors through Single Combustion Air Opening
80 506.5 Combination Indoor and Outdoor Combustion Air.
506.5.1 Indoor Openings.
506.5.2 Outdoor Openings.
506.5.3 Outdoor Opening(s) Size.
506.6 Engineered Installations.
506.7 Mechanical Combustion Air Supply.
506.7.1 Exhaust Fans.
506.7.2 Interlock.
506.7.3 Specified Combustion Air.
506.8 Louvers, Grilles, and Screens.
506.8.1 Minimum Screen Mesh Size.
506.8.2 Motorized Louvers.
506.9 Combustion Air Ducts.
507.0 Appliance
507.1 Dielectric Insulator.
81 507.2 Seismic Provisions.
507.3 Support of Appliances.
507.3.1 Structural Capacity.
507.4 Ground Support.
507.5 Drainage Pan.
507.6 Added or Converted Equipment or Appliances.
507.7 Types of Gases.
507.8 Safety Shutoff Devices for Unlisted LP-Gas Appliance Used Indoors.
507.9 Use of Air or Oxygen Under Pressure.
507.10 Protection of Gas Appliances from Fumes or Gases other than Products of Combustion.
507.11 Process Air.
507.12 Flammable Vapors.
507.13 Installation in Garages.
507.13.1 Physical Damage.
507.13.2 Access from the Outside.
82 507.14 Installation in Commercial Garages.
507.14.1 Parking Structures.
507.14.2 Repair Garages.
507.15 Installation in Aircraft Hangars.
507.16 Venting of Flue Gases.
507.17 Extra Device or Attachment.
507.18 Adequate Capacity of Piping.
507.19 Avoiding Strain on Gas Piping.
507.20 Gas Appliance Pressure Regulators.
507.21 Venting of Gas Appliance Pressure Regulators.
507.22 Bleed Lines for Diaphragm-Type Valves.
507.23 Combination of Appliances and Equipment.
83 507.24 Installation Instructions.
507.25 Protection of Outdoor Appliances.
507.26 Accessibility for Service.
508.0 Equipment and Appliances on Roofs.
508.1 General.
508.1.1 Load Capacity.
508.1.2 Fasteners.
508.2 Installation of Equipment and Appliances on Roofs.
508.2.1 Clearance.
508.2.2 Electrical Power.
508.2.3 Platform or Walkway.
508.3 Access to Equipment and Appliances on Roofs.
508.3.1 Access.
508.3.2 Access Type.
508.3.3 Permanent Lighting.
508.4 Appliances in Attics and Under-Floor Spaces.
508.4.1 Length of Passageway.
508.4.2 Width of Passageway.
84 508.4.3 Work Platform.
508.4.4 Lighting and Convenience Outlet.
509.0 Venting of Appliances.
509.1 Listing.
509.1.1 Installation.
509.1.2 Prohibited Discharge.
509.2 Connection to Venting Systems.
509.2.1 Appliances Not Required to be Vented.
509.2.2 Ventilating Hoods.
509.2.3 Well-Ventilated Spaces.
509.2.4 Direct-Vent Appliances.
509.2.5 Appliances with Integral Vents.
509.3 Design and Construction.
509.3.1 Appliance Draft Requirements.
509.3.2 Appliance Venting Requirements.
509.3.3 Mechanical Draft Systems.
509.3.3.1 Venting.
509.3.3.2 Leakage.
509.3.3.3 Vent Connectors.
509.3.3.4 Operation.
509.3.3.5 Exit Terminals.
85 509.3.4 Ventilating Hoods and Exhaust Systems.
509.3.4.1 Automatically Operated Appliances.
509.3.5 Circulating Air Ducts and Furnace Plenums.
509.4 Type of Venting System to be Used.
509.4.1 Plastic Piping.
509.4.2 Plastic Vent Joints.
509.4.3 Special Gas Vents.
509.5 Masonry, Metal, and Factory-Built Chimneys.
509.5.1 Factory-Built Chimneys.
509.5.1.1 Decorative Shrouds.
509.5.1.2 Listing Requirements.
509.5.2 Metal Chimneys.
509.5.3 Masonry Chimneys.
509.5.4 Termination.
509.5.4.1 Medium-Heat Gas Appliances.
509.5.4.2 Chimney Height.
509.5.4.3 Decorative Shrouds.
509.5.5 Size of Chimneys.
86 509.5.6 Inspection of Chimneys.
Table 509.4 Type of Venting System to be Used
Figure 509.5.4 Typical Termination Locations for Chimneys and Single-Wall Metal Pipes Serving Residential-Type and Low-Heat Appliance
87 509.5.6.1 Standard.
509.5.6.2 Cleanouts.
509.5.6.3 Existing Chimney.
509.5.7 Chimney Serving Appliances Burning Other Fuels.
509.5.7.1 Gas and Liquid Fuel-Burning Appliances.
509.5.7.2 Gas and Solid Fuel-Burning Appliances.
509.5.7.3 Combination Gas- and Oil-Burning Appliances.
509.5.8 Support of Chimneys.
509.5.9 Cleanouts.
509.5.10 Space Surrounding Lining or Vent.
509.5.10.1 Combustion Air.
509.6 Gas Vents.
509.6.1 Fasteners.
509.6.2 Termination Requirements.
509.6.2.1 Type B and L Vents.
509.6.2.2 Type B-W Vents.
88 509.6.2.3 Exterior Wall Termination.
509.6.2.4 Decorative Shrouds.
509.6.2.5 Termination Cap.
509.6.2.6 Forced Air Inlet.
509.6.2.7 Insulation Shield.
509.6.3 Size of Gas Vents.
509.6.3.1 Category I Appliances.
509.6.3.2 Vent Offsets.
509.6.3.3 Sizing.
509.6.4 Gas Vents Serving Appliances on more than One Floor.
Table 509.6.2 Roof Pitch Height
Figure 509.6.2 Gas Vent Termination Locations for Listed Caps 12 Inches or Less in Size Not Less than 8 feet from a Vertical Wall
89 509.6.4.1 Occupiable Space.
509.6.4.2 Multistory Venting System.
509.6.5 Support of Gas Vents.
509.6.6 Marking.
509.7 Single-Wall Metal Pipe.
509.7.1 Cold Climate.
509.7.2 Termination.
509.7.3 Installation with Appliances Permitted by Table 509.4.
509.7.3.1 Limitations.
509.7.3.2 Attic or Concealed Space.
509.7.3.3 Incinerator.
509.7.3.4 Clearances.
Figure 509.6.4.1 Plan View of Practical Separation Method for Multistory Gas Venting
90 509.7.3.5 Combustible Exterior Wall.
509.7.3.6 Roof Thimble.
509.7.4 Size of Single-Wall Metal Pipe.
509.7.4.1 Sizing of Venting System.
509.7.4.2 Non-Round Metal Pipe.
509.7.4.3 Venting Capacity.
509.7.5 Support of Single-Wall Metal Pipe.
509.7.6 Marking.
509.8 Through-the-Wall Vent Termination.
Table 509.7.3(1) Clearance for Connectors
91 509.8.1 Mechanical Draft Venting System.
509.8.2 Direct-Vent Appliance.
509.8.3 Nuisance and Hazard.
Figure 509.7.3(1) Extent of Protection Necessary to Reduce Clearances from Gas Appliances or Vent Connectors
Figure 509.7.3(2) Wall Protection Reduction System
Figure 509.7.3(3) Masonry Clearance Reduction System
92 Table 509.7.3(2) Reduction of Clearances with Specified Forms of Protection
93 509.8.4 Annular Spaces.
509.8.5 Vent Terminals.
509.9 Condensation Drain.
509.9.1 Local Experience.
509.10 Vent Connectors for Category I Appliances.
509.10.1 Materials.
509.10.1.1 Unconditioned Area.
509.10.1.2 Residential-Type Appliances.
Figure 509.8 Exit Terminals of Mechanical Draft and Direct-Vent Venting Systems
94 509.10.1.3 Non-Residential Low-Heat Appliances.
509.10.1.4 Medium-Heat Appliances.
509.10.2 Size of Vent Connector.
509.10.2.1 Manifold.
509.10.2.2 Size.
509.10.2.3 Height.
509.10.2.4 Size Increase.
Table 509.10.1.3 Minimum Thickness for Galvanized Steel Vent Connectors for Low-Heat Appliances
Table 509.10.1.4 Minimum Thickness for Steel Vent Connectors for Medium-Heat Appliances and Commercial and Industrial Incinerators
95 509.10.3 Two or More Appliances Connected toa Single Vent.
509.10.3.1 Height of Connector.
509.10.3.2 Pressure.
509.10.4 Clearance.
509.10.5 Joints.
509.10.6 Slope.
509.10.7 Length of Vent Connector.
509.10.7.1 Single Wall Connector.
509.10.7.2 Type B Double Wall Connector.
509.10.8 Support.
509.10.9 Chimney Connection.
509.10.10 Inspection.
509.10.11 Fireplaces.
509.10.12 Passage through Ceilings, Floors, or Walls.
509.10.12.1 Medium-Heat Appliances.
509.11 Draft Hoods and Draft Controls.
509.11.1 Installation.
96 509.11.2 Draft Control Devices.
509.11.3 Additional Devices.
509.11.4 Location.
509.11.5 Positioning.
509.11.6 Clearance.
509.12 Manually Operated Dampers.
509.13 Automatically Operated Vent Dampers.
509.13.1 Listing.
509.14 Obstructions.
510.0 Sizing of Category I Venting Systems.
510.1 Single Appliance Vent Table 510.1.2(1) through Table 510.1.2(6).
510.1.1 Vent Downsizing.
97 510.1.2 Elbows.
510.1.3 Zero Lateral.
510.1.4 High-Altitude Installations.
510.1.5 Multiple Input Ratings.
510.1.6 Corrugated Chimney Liner Reduction.
510.1.7 Connection to Chimney Liners.
510.1.8 Vertical Vent Upsizing Using 7 x Rule.
510.1.9 Draft Hood Conversion Accessories.
510.1.10 Chimney and Vent Locations.
510.1.11 Corrugated Vent Connector Size.
510.1.12 Upsizing.
510.1.13 Single Run of Vent.
510.1.14 Interpolation.
510.1.15 Extrapolation.
510.1.16 Engineering Methods.
510.1.17 Height Entries.
98 510.2 Multiple Appliance Vent Table 510.2(1) through Table 510.2(9).
510.2.1 Vent Connector Maximum Length.
510.2.2 Vent Connector Exceeding Maximum Length.
510.2.3 Vent Connector Manifold.
510.2.4 Vent Offset.
510.2.5 Elbow Reduction.
510.2.6 Common Vent Minimum Size.
Table 510.2.1 Vent Connector Maximum Length
99 510.2.7 Tee and Wye Fittings.
510.2.8 Size of Fittings.
510.2.9 High-Altitude Installations.
510.2.10 Connector Rise.
510.2.11 Vent Height.
510.2.12 Multistory Installations.
510.2.13 Size of Vents for Multistory Installations.
510.2.14 Vent Type Multistory Installations.
510.2.15 Offsets in Multistory Installations.
510.2.16 Vertical Vent Size Limitation.
510.2.17 Multiple Input Ratings.
510.2.18 Corrugated Metallic Chimney Liner Reduction.
510.2.19 Chimneys and Vents.
100 510.2.20 Vent Connector Sizing.
510.2.21 Combination of Pipe Types and Sizes.
510.2.22 Multiple Connector and Vent Sizes.
510.2.23 Interpolation.
510.2.24 Extrapolation.
510.2.25 Engineering Methods.
510.2.26 Height Entries.
101 Figure 510.1.2(6) Range of Winter Design Temperatures Used in Analyzing Exterior Masonry Chimneys in the United States
102 Table 510.1.2(1) Type B Double-Wall Gas Vent
105 Table 510.1.2(2) Type B Double-Wall Gas Vent
107 Table 510.1.2(3) Masonry Chimney
109 Table 510.1.2(4) Masonry Chimney
111 Table 510.1.2(5) Single-Wall Metal Pipe or Type B Asbestos-Cement Vent
112 Table 510.1.2(6) Exterior Masonry Chimney
113 Table 510.2(1) Type B Double-Wall Vent
117 Table 510.2(2) Type B Double-Wall Vent
119 Table 510.2(3) Masonry Chimney
121 Table 510.2(4) Masonry Chimney
123 Table 510.2(5) Single-Wall Metal Pipe or Type B Asbestos-Cement Vent
Table 510.2(6) Exterior Masonry Chimney
124 Table 510.2(7) Exterior Masonry Chimney
125 Table 510.2(8) Exterior Masonry Chimney
126 Table 510.2(9) Exterior Masonry Chimney
128 Chapter 6 Water Supply and Distribution
601.0 General.
601.1 Applicability.
601.2 Hot and Cold Water Required.
601.3 Identification of a Potable and Nonpotable Water System.
601.3.1 Potable Water.
601.3.2 Color and Information.
601.3.3 Alternate Water Sources.
601.3.4 Fixtures.
601.3.5 Outlets.
602.0 Unlawful Connections.
602.1 Prohibited Installation.
TABLES
Table 601.3.2 Minimum Length of Color Field and Size of Letters
129 602.2 Cross-Contamination.
602.3 Backflow Prevention.
602.4 Approval by Authority.
603.0 Cross-Connection Control.
603.1 General.
603.2 Approval of Devices or Assemblies.
603.3 Backflow Prevention Devices, Assemblies, and Methods.
603.3.1 Air Gap.
603.3.2 Atmospheric Vacuum Breaker (AVB).
603.3.3 Hose Connection Backflow Preventer.
603.3.4 Double Check Valve Backflow Prevention Assembly (DC).
603.3.5 Pressure Vacuum Breaker Backflow Prevention Assembly (PVB).
603.3.6 Spill-Resistant Pressure Vacuum Breaker (SVB).
603.3.7 Reduced-Pressure Principle Backflow Prevention Assembly (RP).
603.3.8 Double Check Detector Fire Protection Backflow Prevention Assembly.
130 Table 603.2 Backflow Prevention Devices, Assemblies, and Methods
132 603.3.9 Reduced Pressure Detector Fire Protection Backflow Prevention Assembly.
603.4 General Requirements.
603.4.1 Backflow Prevention Valve.
603.4.2 Testing.
603.4.3 Access and Clearance.
603.4.4 Connections.
603.4.5 Hot Water Backflow Preventers.
603.4.6 Integral Backflow Preventers.
603.4.7 Freeze Protection.
Table 603.3.1 Minimum Air Gaps for Water Distribution
133 603.4.8 Drain Lines.
603.4.9 Prohibited Locations.
603.5 Specific Requirements.
603.5.1 Atmospheric Vacuum Breaker.
603.5.2 Ballcock.
603.5.3 Backflow Prevention.
603.5.4 Heat Exchangers.
603.5.5 Water Supply Inlets.
603.5.6 Protection from Lawn Sprinklers and Irrigation Systems.
603.5.6.1 Systems with Pumps.
603.5.6.2 Systems with Backflow Devices.
603.5.6.3 Systems with Chemical Injectors.
603.5.7 Outlets with Hose Attachments.
603.5.8 Water-Cooled Equipment.
134 603.5.9 Aspirators.
603.5.10 Steam or Hot Water Boilers.
603.5.11 Nonpotable Water Piping.
603.5.12 Beverage Dispensers.
603.5.13 Deck-Mounted and Equipment-Mounted Vacuum Breakers.
603.5.14 Protection from Fire Systems.
603.5.14.1 Fire Department Connection.
603.5.14.2 Chemicals.
603.5.14.3 Hydraulic Design.
603.5.15 Health Care or Laboratory Areas.
603.5.16 Special Equipment.
603.5.17 Potable Water Outlets and Valves.
135 603.5.18 Pure Water Process Systems.
603.5.18.1 Dialysis Water Systems.
603.5.19 Plumbing Fixture Fittings.
603.5.20 Swimming Pools, Spas, and Hot Tubs.
604.0 Materials.
604.1 Pipe, Tube, and Fittings.
604.2 Lead Content.
604.2.1 Lead Content of Water Supply Pipe and Fittings.
604.3 Copper or Copper Alloy Tube.
604.4 Hard-Drawn Copper or Copper Alloy Tubing.
604.5 Flexible Connectors.
604.6 Cast-Iron Fittings.
604.7 Malleable Iron Fittings.
604.8 Previously Used Piping and Tubing.
604.9 Epoxy Coating.
604.10 Plastic Materials.
604.10.1 Tracer Wire.
604.11 Solder.
136 604.12 Flexible Corrugated Connectors.
604.13 Water Heater Connectors.
605.0 Joints and Connections.
605.1 Copper or Copper Alloy Pipe, Tubing, and Joints.
605.1.1 Brazed Joints.
Table 604.1 Materials for Building Supply and Water Distribution Piping and Fittings
137 605.1.2 Flared Joints.
605.1.3 Mechanical Joints.
605.1.3.1 Mechanically Formed Tee Fittings.
605.1.3.2 Pressed Fittings.
605.1.3.3 Push Fit Fittings.
605.1.4 Soldered Joints.
605.1.5 Threaded Joints.
605.2 CPVC Plastic Pipe and Joints.
605.2.1 Mechanical Joints.
605.2.2 Solvent Cement Joints.
138 605.2.3 Threaded Joints.
605.3 CPVC/AL/CPVC Plastic Pipe and Joints.
605.3.1 Solvent Cement Joints.
605.4 Ductile Iron Pipe and Joints.
605.4.1 Mechanical Joints.
605.4.2 Push-On Joints.
605.5 Galvanized Steel Pipe and Joints.
605.5.1 Mechanical Joints.
605.5.2 Threaded Joints.
605.6 PE Plastic Pipe/Tubing and Joints.
605.6.1 Heat-Fusion Joints.
605.6.1.1 Butt-Fusion Joints.
605.6.1.2 Electro-Fusion Joints.
605.6.1.3 Socket-Fusion Joints.
139 605.6.2 Mechanical Joints.
605.7 PE-AL-PE Plastic Pipe/Tubing and Joints.
605.7.1 Mechanical Joints.
605.7.1.1 Compression Joints.
605.8 PE-RT.
605.8.1 Fittings.
605.9 PEX Plastic Tubing and Joints.
605.9.1 Fittings.
605.9.2 Mechanical Joints.
605.10 PEX-AL-PEX Plastic Tubing and Joints.
605.10.1 Mechanical Joints.
605.10.1.1 Compression Joints.
605.11 Polypropylene (PP) Piping and Joints.
605.11.1 Heat-Fusion Joints.
605.11.2 Mechanical and Compression Sleeve Joints.
140 605.11.3 Threaded Joints.
605.12 PVC Plastic Pipe and Joints.
605.12.1 Mechanical Joints.
605.12.2 Solvent Cement Joints.
605.12.3 Threaded Joints.
605.13 Stainless Steel Pipe and Joints.
605.13.1 Mechanical Joints.
605.13.2 Welded Joints.
605.14 Slip Joints.
605.15 Dielectric Unions.
605.16 Joints Between Various Materials.
605.16.1 Copper or Copper Alloy Pipe or Tubing to Threaded Pipe Joints.
605.16.2 Plastic Pipe to Other Materials.
605.16.3 Stainless Steel to Other Materials.
606.0 Valves.
606.1 General.
606.2 Fullway Valve.
141 606.3 Multidwelling Units.
606.4 Multiple Openings.
606.5 Control Valve.
606.6 Accessible.
606.7 Multiple Fixtures.
607.0 Potable Water Supply Tanks.
607.1 General.
607.2 Potable Water Tanks.
607.3 Venting.
607.4 Overflow.
607.5 Valves.
608.0 Water Pressure, Pressure Regulators, Pressure Relief Valves, and Vacuum Relief Valves.
608.1 Inadequate Water Pressure.
608.2 Excessive Water Pressure.
608.3 Expansion Tanks, and Combination Temperature and Pressure-Relief Valves.
142 608.4 Pressure Relief Valves.
608.5 Discharge Piping.
608.6 Water-Heating Devices.
608.7 Vacuum Relief Valves.
609.0 Installation, Testing, Unions, and Location.
609.1 Installation.
609.2 Trenches.
609.3 Under Concrete Slab.
609.4 Testing.
609.5 Unions.
609.6 Location.
609.7 Abutting Lot.
143 609.8 Low-Pressure Cutoff Required on Booster Pumps for Water Distribution Systems.
609.9 Disinfection of Potable Water System.
609.10 Water Hammer.
609.10.1 Mechanical Devices.
609.11 Pipe Insulation.
609.11.1 Insulation Requirements.
609.11.2 Pipe Insulation Wall Thickness.
610.0 Size of Potable Water Piping.
610.1 Size.
610.2 Pressure Loss.
610.3 Quantity of Water.
610.4 Sizing Water Supply and Distribution Systems.
144 Table 610.3 Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes
145 Table 610.4 Fixture Unit Table for Determining Water Pipe and Meter Sizes
146 610.5 Sizing per Appendices A and C.
610.6 Friction and Pressure Loss.
610.7 Conditions for Using Table 610.4.
610.8 Size of Meter and Building Supply Pipe Using Table 610.4.
610.9 Size of Branches.
610.10 Sizing for Flushometer Valves.
Table 610.10 Flushometer Fixture Units for Water Sizing Using Table 610.3
147 610.11 Sizing Systems for Flushometer Tanks.
610.12 Sizing for Velocity.
610.12.1 Copper Tube Systems.
610.12.2 Tubing Systems Using Copper Fittings.
610.13 Exceptions.
611.0 Drinking Water Treatment Units.
611.1 Application.
611.2 Air Gap Discharge.
611.3 Connection Tubing.
611.4 Sizing of Residential Softeners.
612.0 Residential Fire Sprinkler Systems.
612.1 Where Required.
148 612.2 Types of Systems.
612.3 Sprinklers.
612.3.1 Required Sprinkler Locations.
612.3.2 Sprinkler Installation.
612.3.3 Temperature Rating and Separation from Heat Sources.
612.3.3.1 Intermediate Temperature Sprinklers.
612.3.4 Freezing Areas.
612.3.5 Coverage Area Limit.
612.3.6 Obstructions to Sprinkler Coverage.
Table 611.4 Sizing of Residential Water Softeners
149 612.3.6.1 Additional Requirements for Pendent Sprinklers.
612.3.6.2 Additional Requirements for Sidewall Sprinklers.
612.3.7 Sprinkler Modifications Prohibited.
612.4 Sprinkler Piping System.
612.4.1 General.
612.4.2 Nonmetallic Pipe and Tubing.
612.4.2.1 Nonmetallic Pipe Protection.
612.4.2.2 Sprinkler Installation on Systems Assembled with Solvent Cement.
612.4.3 Shutoff Valves Prohibited.
612.4.4 Single Dwelling Limit.
612.4.5 Drain.
612.5 Sprinkler Piping Design.
612.5.1 Determining System Design Flow.
612.5.1.1 Determining Required Flow Rate for Each Sprinkler.
612.5.1.2 System Flow Rate.
Table 612.3.3.1 Location where Intermediate Temperature Sprinklers are Required
150 Table 612.3.6 Minimum Separation from Obstruction
151 612.5.2 Sprinkler Pipe Water Supply.
612.5.2.1 Water Pressure from Individual Sources.
612.5.2.2 Required Capacity.
612.5.3 Sprinkler Pipe Sizing.
612.5.3.1 Sprinkler Pipe Sizing Method.
612.5.3.2 Prescriptive Pipe Sizing Method.
612.5.3.2.1 Available Pressure Equation.
612.5.3.2.2 Calculation Procedure.
152 Table 612.5.3.2(1) Water Service Pressure Loss (PLws)
153 612.6 Instructions and Signs.
612.7 Inspection and Testing.
612.7.1 Pre-Concealment Inspection.
612.7.2 Final Inspection.
Table 612.5.3.2(2) Minimum Water Meter Pressure Loss (PLm)
Table 612.5.3.2(3) Elevation Loss (PLe)
154 Table 612.5.3.2(4) Allowable Pipe Length for 3/4 Inch Type M Copper Water Tubing
155 Table 612.5.3.2(5) Allowable Pipe Length for 1 Inch Type M Copper Water Tubing
156 Table 612.5.3.2(6) Allowable Pipe Length for 3/4 IInch IPS CPVC Pipe
157 Table 612.5.3.2(7) Allowable Pipe Length for 1 Inch IPS CPVC Pipe
158 Table 612.5.3.2(8) Allowable Pipe Length for 3/4 Inch PEX Tubing
159 Table 612.5.3.2(9) Allowable Pipe Length for 1 Inch PEX Tubing
160 Chapter 7 Sanitary Drainage
Part I – Drainage Systems.
701.0 General.
701.1 Applicability.
701.2 Drainage Piping.
701.3 Drainage Fittings.
701.3.1 Screwed Pipe.
701.3.2 Threads.
701.3.3 Type.
701.4 Continuous Wastes.
701.5 Lead.
701.6 Caulking Ferrules.
701.7 Soldering Bushings.
702.0 Fixture Unit Equivalents.
702.1 Trap Size.
TABLES
Table 701.6 Caulking Ferrules
Table 701.7 Soldering Bushings
161 Table 701.2 Materials for Drain, Waste, Vent Pipe and Fittings
162 Table 702.1 Drainage Fixture Unit Values (DFU)
163 702.2 Intermittent Flow.
702.3 Continuous Flow.
703.0 Size of Drainage Piping.
703.1 Minimum Size.
703.2 Maximum Number of Fixture Units.
703.3 Sizing per Appendix C.
704.0 Fixture Connections (Drainage).
704.1 Inlet Fittings.
704.2 Single Vertical Drainage Pipe.
704.3 Commercial Sinks.
705.0 Joints and Connections.
705.1 ABS and ABS Co-Extruded Plastic Pipe and Joints.
705.1.1 Mechanical Joints.
705.1.2 Solvent Cement Joints.
705.1.3 Threaded Joints.
705.2 Cast-Iron Pipe and Joints.
705.2.1 Caulked Joints.
Table 702.2(1) Maximum Drainage Fixture Units for a Trap and Trap Arm
Table 702.2(2) Discharge Capacity in Gallons per Minute for Intermittent Flow Only
164 705.2.2 Mechanical Joints and Compression Joints.
705.3 Copper or Copper Alloy Pipe (DWV) and Joints.
705.3.1 Brazed Joints.
705.3.2 Mechanical Joints.
705.3.3 Soldered Joints.
Table 703.2 Maximum Unit Loading and Maximum Length of Drainage and Vent Piping
165 705.3.4 Threaded Joints.
705.4 Galvanized Steel Pipe and Joints.
705.4.1 Mechanical Joints.
705.4.2 Threaded Joints.
705.5 PVC and PVC Co-Extruded Plastic Pipe and Joining Methods.
705.5.1 Mechanical Joints.
705.5.2 Solvent Cement Joints.
705.5.3 Threaded Joints.
705.6 Stainless Steel Pipe and Joints.
705.6.1 Mechanical Joints.
705.6.2 Welded Joints.
705.7 Vitrified Clay Pipe and Joints.
705.7.1 Mechanical Joints.
705.8 Special Joints.
705.8.1 Slip Joints.
705.8.2 Expansion Joints.
166 705.8.3 Ground Joint, Flared, or Ferrule Connections.
705.8.4 Transition Joint.
705.9 Joints Between Various Materials.
705.9.1 Copper or Copper Alloy Pipe to Cast-Iron Pipe.
705.9.2 Copper or Copper Alloy Pipe toThreaded Pipe Joints.
705.9.3 Plastic Pipe to Other Materials.
705.9.4 Stainless Steel Pipe to Other Materials.
706.0 Changes in Direction of Drainage Flow.
706.1 Approved Fittings.
706.2 Horizontal to Vertical.
706.3 Horizontal to Horizontal.
706.4 Vertical to Horizontal.
707.0 Cleanouts.
707.1 Plug.
707.2 Approved.
707.3 Watertight and Gastight.
707.4 Location.
Table 707.1 Cleanouts
167 707.5 Cleaning.
707.6 Extension.
707.7 Interceptor.
707.8 Access.
707.9 Clearance.
707.10 Fittings.
707.11 Pressure Drainage Systems.
707.12 Countersunk Cleanout Plugs.
707.13 Hubless Blind Plugs.
707.14 Trap Arms.
708.0 Grade of Horizontal Drainage Piping.
708.1 General.
709.0 Gravity Drainage Required.
709.1 General.
710.0 Drainage of Fixtures Located Below the Next Upstream Manhole or Below the Main Sewer Level.
710.1 Backflow Protection.
710.2 Sewage Discharge.
710.3 Sewage Ejector and Pumps.
168 710.4 Discharge Line.
710.5 Size of Building Drains and Sewers.
710.6 Backwater Valves.
710.7 Drainage and Venting Systems.
710.8 Sump and Receiving Tank Construction.
710.9 Alarm.
710.10 Sump and Receiving Tank Covers and Vents.
710.11 Air Tanks.
710.12 Grinder Pump Ejector.
710.12.1 Discharge Piping.
710.13 Macerating Toilet Systems and Pumped Waste Systems.
710.13.1 Sumps.
169 710.13.2 Discharge Piping.
710.13.3 Venting.
711.0 Suds Relief.
711.1 General.
712.0 Testing.
712.1 Media.
712.2 Water Test.
712.3 Air Test.
Part II – Building Sewers.
713.0 Sewer Required.
713.1 Where Required.
713.2 Private Sewage Disposal System.
713.3 Public Sewer.
713.4 Public Sewer Availability.
713.5 Permit.
713.6 Lot.
713.7 Installation.
170 714.0 Damage to Public Sewer or Private Sewage Disposal System.
714.1 Unlawful Practices.
714.2 Prohibited Water Discharge.
714.3 Prohibited Sewer Connection.
714.4 Commercial Food Waste Disposer.
714.5 Tanks.
715.0 Building Sewer Materials.
715.1 Materials.
715.2 Joining Methods and Materials.
715.3 Existing Sewers.
716.0 Markings.
716.1 General.
717.0 Size of Building Sewers.
717.1 General.
718.0 Grade, Support, and Protection of Building Sewers.
718.1 Slope.
718.2 Support.
718.3 Protection from Damage.
Table 717.1 Maximum/Minimum Fixture Unit Loading on Building Sewer Piping
171 719.0 Cleanouts.
719.1 Locations.
719.2 No Additional Cleanouts.
719.3 Building Sewer Cleanouts.
719.4 Cleaning.
719.5 Access.
719.6 Manholes.
720.0 Sewer and Water Pipes.
720.1 General.
721.0 Location.
721.1 Building Sewer.
721.2 Abutting Lot.
722.0 Abandoned Sewers and Sewage Disposal Facilities.
722.1 Building (House) Sewer.
722.2 Cesspools, Septic Tanks, and Seepage Pits.
722.3 Filling.
722.4 Ownership.
172 722.5 Disposal Facilities.
723.0 Building Sewer Test.
723.1 General.
Table 721.1 Minimum Horizontal Distance Required from Building Sewer (feet)
174 Chapter 8 Indirect Wastes
801.0 General.
801.1 Applicability.
801.2 Air Gap or Air Break Required.
801.3 Food and Beverage Handling Establishments.
801.3.1 Size of Indirect Waste Pipes.
801.3.2 Walk-In Coolers.
801.3.3 Food-Handling Fixtures.
801.4 Bar and Fountain Sink Traps.
801.5 Connections from Water Distribution System.
801.6 Sterilizers.
801.7 Drip or Drainage Outlets.
802.0 Approvals.
802.1 General.
803.0 Indirect Waste Piping.
803.1 Materials.
803.2 Copper and Copper Alloys.
803.3 Pipe Size and Length.
TABLES
175 804.0 Indirect Waste Receptors.
804.1 Standpipe Receptors.
805.0 Pressure Drainage Connections.
805.1 General.
806.0 Sterile Equipment.
806.1 General.
807.0 Appliances.
807.1 Non-Classed Apparatus.
807.2 Undiluted Condensate Waste.
807.3 Domestic Dishwashing Machine.
808.0 Cooling Water.
808.1 General.
809.0 Drinking Fountains.
809.1 General.
810.0 Steam and Hot Water Drainage Condensers and Sumps.
810.1 High Temperature Discharge.
176 810.2 Sumps, Condensers, and Intercepting Tanks.
810.3 Cleaning.
810.4 Strainers.
811.0 Chemical Wastes.
811.1 Pretreatment.
811.2 Waste and Vent Pipes.
811.3 Joining Materials.
811.4 Access.
811.5 Permanent Record.
811.6 Chemical Vent.
811.7 Discharge.
811.8 Diluted Chemicals.
812.0 Clear Water Wastes.
812.1 General.
813.0 Swimming Pools.
813.1 General.
TABLE 810.1 Pipe Connections in Blowoff Condensers and Sumps (inches)
177 814.0 Condensate Waste and Control.
814.1 Condensate Disposal.
814.1.1 Condensate Pumps.
814.2 Condensate Control.
814.2.1 Protection of Appurtenances.
814.3 Condensate Waste Pipe Material and Sizing.
814.3.1 Cleanouts.
814.4 Appliance Condensate Drains.
Table 814.3 Minimum Condensate Pipe Size
178 814.5 Point of Discharge.
814.6 Condensate Waste From Air-Conditioning Coils.
814.7 Plastic Fittings.
180 Chapter 9 Vents
901.0 General.
901.1 Applicability.
901.2 Vents Required.
901.3 Trap Seal Protection.
902.0 Vents Not Required.
902.1 Interceptor.
902.2 Bars, Soda Fountains, and Counter.
903.0 Materials.
903.1 Applicable Standards.
903.2 Use of Copper or Copper Alloy Tubing.
903.2.1 Aboveground.
903.2.2 Prohibited Use.
903.2.3 Marking.
903.3 Changes in Direction.
904.0 Size of Vents.
904.1 Size.
904.2 Length.
181 905.0 Vent Pipe Grades and Connections.
905.1 Grade.
905.2 Horizontal Drainage Pipe.
905.3 Vent Pipe Rise.
905.4 Roof Termination.
905.5 Location of Opening.
905.6 Common Vertical Pipe.
906.0 Vent Termination.
906.1 Roof Termination.
906.2 Clearance.
906.3 Use of Roof.
906.4 Outdoor Installations.
906.5 Joints.
906.6 Lead.
906.7 Frost or Snow Closure.
907.0 Vent Stacks and Relief Vents.
907.1 Drainage Stack.
907.2 Yoke Vent.
908.0 Wet Venting.
908.1 Vertical Wet Venting.
908.1.1 Size.
182 908.1.2 Vent Connection.
908.2 Horizontal Wet Venting for a Bathroom Group.
908.2.1 Vent Connection.
908.2.2 Size.
908.2.3 Trap Arm.
908.2.4 Water Closet.
908.2.5 Additional Fixtures.
909.0 Special Venting for Island Fixtures.
909.1 General.
910.0 Combination Waste and Vent Systems.
910.1 Where Permitted.
910.2 Approval.
910.3 Vents.
910.4 Size.
910.5 Vertical Waste Pipe.
910.6 Cleanouts.
910.7 Fixtures.
183 911.0 Circuit Venting.
911.1 Circuit Vent Permitted.
911.1.1 Multiple Circuit-Vented Branches.
911.2 Vent Size and Connection.
911.3 Slope and Size of Horizontal Branch.
911.3.1 Size of Multiple Circuit Vent.
911.4 Relief Vent.
911.4.1 Connection and Installation.
911.4.2 Fixture Drain or Branch.
911.5 Additional Fixtures.
912.0 Engineered Vent System.
912.1 General.
912.2 Minimum Requirements.
184 Chapter 10 Traps and Interceptors
1001.0 General.
1001.1 Applicability.
1001.2 Where Required.
1002.0 Traps Protected by Vent Pipes.
1002.1 Vent Pipes.
1002.2 Fixture Traps.
1002.3 Change of Direction.
1002.4 Vent Pipe Opening.
1003.0 Traps — Described.
1003.1 General Requirements.
1003.2 Slip Joint Fittings.
TABLES
TABLE 1002.2 Horizontal Lengths of Trap Arms (Except for Water Closets and Similar Fixtures)
185 1003.3 Size.
1004.0 Traps.
1004.1 Prohibited.
1004.2 Movable Parts.
1005.0 Trap Seals.
1005.1 General.
1006.0 Floor Drain Traps.
1006.1 General.
1007.0 Trap Seal Protection.
1007.1 General.
1008.0 Building Traps.
1008.1 General.
1009.0 Interceptors (Clarifiers) and Separators.
1009.1 Where Required.
1009.2 Approval.
1009.3 Design.
1009.4 Relief Vent.
1009.5 Location.
1009.6 Maintenance of Interceptors.
1009.7 Discharge.
1010.0 Slaughterhouses, Packing Establishments, etc.
1010.1 General.
1011.0 Minimum Requirements for Auto Wash Racks.
1011.1 General.
186 1012.0 Commercial and Industrial Laundries.
1012.1 General.
1013.0 Bottling Establishments.
1013.1 General.
1014.0 Grease Interceptors.
1014.1 General.
1014.1.1 Trapped and Vented.
1014.1.2 Maintenance.
1014.1.3 Food Waste Disposers and Dishwashers.
1014.2 Hydromechanical Grease Interceptors.
1014.2.1 Capacity.
1014.2.2 Vent.
1014.3 Gravity Grease Interceptors.
1014.3.1 General.
1014.3.2 Waste Discharge Requirements.
187 1014.3.2.1 Toilets and Urinals.
1014.3.2.2 Inlet Pipe.
1014.3.3 Design.
1014.3.4 Location.
1014.3.4.1 Interceptors.
1014.3.4.2 Business Establishment.
1014.3.4.3 Access.
1014.3.5 Construction Requirements.
1014.3.6 Sizing Criteria.
1014.3.7 Abandoned Gravity Grease Interceptors.
Table 1014.2.1 Hydromechanical Grease Interceptor Sizing Using Gravity Flow Rates
188 1015.0 FOG (Fats, Oils, and Greases) Disposal System.
1015.1 Purpose.
1015.2 Components, Materials, and Equipment.
1015.3 Sizing and Installation.
1015.4 Performance.
1016.0 Sand Interceptors.
1016.1 Discharge.
1016.2 Authority Having Jurisdiction.
1016.3 Construction and Size.
Table 1014.3.6 Gravity Grease Interceptor Sizing
189 1016.4 Separate Use.
1017.0 Oil and Flammable Liquid Interceptors.
1017.1 Interceptors Required.
1017.2 Design of Interceptors.
190 Chapter 11 Storm Drainage
1101.0 General.
1101.1 Applicability.
1101.2 Where Required.
1101.3 Storm Water Drainage to Sanitary Sewer Prohibited.
1101.4 Material Uses.
1101.4.1 Copper and Copper Alloys.
1101.4.2 Conductors.
1101.4.3 Leaders.
1101.4.4 Underground Building Storm Drains.
1101.4.5 Building Storm Sewers.
1101.4.6 Subsoil Drains.
1101.5 Expansion Joints Required.
1101.6 Subsoil Drains.
1101.6.1 Discharge.
1101.6.2 Sump.
TABLES
Table 1101.4.6 Materials for Subsoil Drain Pipe and Fittings
191 1101.6.3 Splash Blocks.
1101.6.4 Backwater Valve.
1101.6.5 Open Area.
1101.7 Building Subdrains.
1101.8 Areaway Drains.
1101.9 Window Areaway Drains.
1101.10 Filling Stations and Motor Vehicle Washing Establishments.
1101.11 Paved Areas.
1101.12 Roof Drainage.
1101.12.1 Primary Roof Drainage.
1101.12.2 Secondary Drainage.
1101.12.2.1 Roof Scuppers or Open Side.
1101.12.2.2 Secondary Roof Drain.
1101.12.2.2.1 Separate Piping System.
192 1101.12.2.2.2 Combined System.
1101.13 Cleanouts.
1101.13.1 Rain Leaders and Conductors.
1101.14 Rainwater Sumps.
1101.15 Traps on Storm Drains and Leaders.
1101.15.1 Where Not Required.
1101.15.2 Trap Size.
1101.15.3 Method of Installation of Combined Sewer.
1101.16 Leaders, Conductors, and Connections.
1101.16.1 Protection of Leaders.
1101.16.2 Combining Storm with Sanitary Drainage.
1102.0 Roof Drains.
1102.1 Applications.
1102.2 Dome Strainers Required.
1102.3 Roof Drain Flashings.
1102.3.1 Lead Flashing.
1102.3.2 Copper Flashing.
1103.0 Size of Leaders, Conductors, and Storm Drains.
1103.1 Vertical Conductors and Leaders.
1103.2 Size of Horizontal Storm Drains and Sewers.
1103.3 Size of Roof Gutters.
1103.4 Side Walls Draining onto a Roof.
193 1104.0 Values for Continuous Flow.
1104.1 General.
1105.0 Controlled-Flow Roof Drainage.
1105.1 Application.
1105.2 Setback Roofs.
Table 1105.1(1) Controlled-Flow Maximum Roof Water Depth
Table 1105.1(2) Distance of Scupper Bottoms Above Roof
194 1106.0 Testing.
1106.1 Testing Required.
1106.2 Methods of Testing Storm Drainage Systems.
1106.2.1 Water Test.
1106.2.2 Air Test.
1106.2.3 Exceptions.
195 Table 1101.8 Sizing of Horizontal Rainwater Piping
196 Table 1101.12 Sizing Roof Drains, Leaders, and Vertical Rainwater Piping
197 Table 1103.3 Size of Gutters
198 Chapter 12 Fuel Gas Piping
1201.0 General.
1201.1 Applicability.
1202.0 Coverage of Piping System.
1202.1 General.
1202.2 Piping System Requirements.
1202.3 Applications.
1203.0 Inspection.
1203.1 Inspection Notification.
1203.2 Excavation.
1203.3 Type of Inspections.
1203.3.1 Rough Piping Inspection.
1203.3.2 Final Piping Inspection.
1203.4 Inspection Waived.
TABLES
FIGURES
199 1204.0 Certificate of Inspection.
1204.1 Issuance.
1204.2 Gas Supplier.
1204.3 Unlawful.
1205.0 Authority to Render Gas Service.
1205.1 Authorized Personnel.
1205.2 Outlets.
1206.0 Authority to Disconnect.
1206.1 Disconnection.
1206.2 Notice.
1206.3 Capped Outlets.
1207.0 Temporary Use of Gas.
1207.1 General.
1208.0 Gas Piping System Design, Materials, and Components.
1208.1 Installation of Piping System.
1208.1.1 Addition to Existing System.
1208.2 Provision for Location of Point of Delivery.
1208.3 Interconnections Between Gas Piping Systems.
1208.3.1 Interconnections for Standby Fuels.
1208.4 Sizing of Gas Piping Systems.
1208.4.1 Maximum Gas Demand.
200 1208.4.2 Sizing Methods.
1208.4.3 Allowable Pressure Drop.
1208.5 Acceptable Piping Materials and Joining Methods.
1208.5.1 Materials.
1208.5.1.1 Other Materials.
1208.5.2 Metallic Pipe.
1208.5.2.1 Steel and Wrought-Iron.
1208.5.2.2 Copper and Copper Alloy.
1208.5.2.3 Aluminum Alloy.
1208.5.3 Metallic Tubing.
1208.5.3.1 Steel.
Table 1208.4.1 Approximate Gas Input for Typical Appliances
201 1208.5.3.2 Copper and Copper Alloy.
1208.5.3.3 Aluminum Alloy.
1208.5.3.4 Corrugated Stainless Steel.
1208.5.4 Plastic Pipe, Tubing, and Fittings.
1208.5.4.1 Regulator Vent Piping.
1208.5.4.2 Anodeless Risers.
1208.5.4.2.1 Factory-Assembled Anodeless Risers.
1208.5.4.2.2 Service Head Adapters and Field-Assembled Anodeless Risers.
1208.5.4.2.3 Undiluted Liquefied Petroleum Gas Piping.
1208.5.5 Workmanship and Defects.
1208.5.6 Protective Coating.
1208.5.7 Metallic Pipe Threads.
1208.5.7.1 Damaged Threads.
1208.5.7.2 Number of Threads.
1208.5.7.3 Thread Joint Compounds.
1208.5.8 Metallic Piping Joints and Fittings.
1208.5.8.1 Pipe Joints.
Table 1208.5.7.2 Specifications for Threading Metallic Pipe
202 1208.5.8.2 Tubing Joints.
1208.5.8.3 Flared Joints.
1208.5.8.4 Metallic Pipe Fittings (Including Valves, Strainers, Filters).
1208.5.9 Plastic Piping, Joints, and Fittings.
1208.5.9.1 Joint Design.
1208.5.9.2 Heat-Fusion Joint.
1208.5.9.3 Compression-Type Mechanical Joints.
1208.5.9.4 Liquefied Petroleum Gas Piping Systems.
1208.5.10 Flanges.
1208.5.10.1 Flange Facings.
1208.5.10.2 Lapped Flanges.
1208.5.11 Flange Gaskets.
203 1208.6 Gas Meters.
1208.6.1 Location.
1208.6.1.1 Subject to Damage.
1208.6.1.2 Extreme Temperatures.
1208.6.2 Supports.
1208.6.3 Meter Protection.
1208.6.4 Identification.
1208.7 Gas Pressure Regulators.
1208.7.1 Overpressure Protection.
1208.7.2 Listing.
1208.7.3 Location.
1208.7.4 Regulator Protection.
1208.7.5 Venting of Line Pressure Regulators.
1208.7.6 Venting of Gas Appliance Pressure Regulators.
204 1208.7.7 Discharge of Vents.
1208.7.8 Bypass Piping.
1208.7.9 Identification.
1208.8 Backpressure Protection.
1208.8.1 Protective Devices.
1208.9 Low-Pressure Protection.
1208.10 Shutoff Valves.
1208.11 Expansion and Flexibility.
1208.11.1 Special Local Conditions.
1209.0 Excess Flow Valve.
1209.1 General.
1210.0 Gas Piping Installation.
1210.1 Piping Underground.
1210.1.1 Cover Requirements.
205 1210.1.2 Trenches.
1210.1.2.1 Backfilling.
1210.1.3 Protection Against Corrosion.
1210.1.4 Protection Against Freezing.
1210.1.5 Piping Through Foundation Wall.
1210.1.6 Piping Underground Beneath Buildings.
1210.1.6.1 Conduit with One End Terminating Outdoors.
1210.1.6.2 Conduit with Both Ends Terminating Indoors.
1210.1.7 Plastic Piping.
1210.1.7.1 Connections Between Metallic and Plastic Piping.
1210.1.7.2 Tracer Wire.
1210.2 Installation of Piping.
1210.2.1 Building Structure.
1210.2.2 Gas Piping to be Sloped.
1210.2.2.1 Ceiling Locations.
206 1210.2.3 Prohibited Locations.
1210.2.4 Hangers, Supports, and Anchors.
1210.2.4.1 Spacing.
1210.2.4.2 Expansion and Contraction.
1210.2.5 Removal of Piping.
1210.3 Concealed Piping in Buildings.
1210.3.1 Connections.
1210.3.2 Piping in Partitions.
1210.3.3 Tubing in Partitions.
1210.3.4 Piping in Floors.
1210.4 Piping in Vertical Chases.
1210.4.1 Pressure Reduction.
Table 1210.2.4.1 Support of Piping
207 1210.4.2 Construction.
1210.4.3 Ventilation.
1210.5 Maximum Design Operating Pressure.
1210.6 Appliance Overpressure Protection.
1210.7 Gas Pipe Turns.
1210.7.1 Metallic Pipe.
1210.7.2 Plastic Pipe.
1210.7.3 Elbows.
1210.8 Drips and Sediment Traps.
1210.8.1 Location of Drips.
1210.8.2 Sediment Traps.
1210.9 Outlets.
208 1210.9.1 Cap Outlets.
1210.9.1.1 Appliance Shutoff Valves.
1210.10 Branch Pipe Connection.
1210.11 Manual Gas Shutoff Valves.
1210.11.1 Valves Controlling Multiple Systems.
1210.11.1.1 Shutoff Valves for Multiple House Lines.
1210.11.2 Emergency Shutoff Valves.
1210.11.3 Shutoff Valve for Laboratories.
1210.12 Prohibited Devices.
1210.13 Systems Containing Gas-Air Mixtures Outside the Flammable Range.
1210.14 Systems Containing Flammable Gas-Air Mixtures.
1211.0 Electrical Bonding and Grounding.
1211.1 Pipe and Tubing other than CSST.
1211.2 Bonding of CSST Gas Piping.
1211.3 Grounding Conductor or Electrode.
1211.4 Lightning Protection System.
1211.5 Electrical Circuits.
1211.6 Electrical Connections.
209 1211.6.1 Safety Control.
1212.0 Appliance Connections to Building Piping.
1212.1 Connecting Gas Appliances.
1212.1.1 Commercial Cooking Appliances.
1212.1.2 Restraining Device.
1212.2 Suspended Low-Intensity Infrared Tube Heaters.
1212.3 Use of Gas Hose Connectors.
1212.3.1 Indoor.
1212.3.2 Outdoor.
1212.4 Connection of Portable and Mobile Industrial Gas Appliances.
1212.4.1 Swivel Joints or Couplings.
1212.4.2 Metal Flexible Connectors.
1212.4.3 Flexible Connectors.
1212.5 Appliance Shutoff Valves and Connections.
210 1212.6 Quick-Disconnect Devices.
1212.7 Gas Convenience Outlets.
1212.8 Sediment Trap.
1212.9 Installation of Piping.
1212.10 Liquefied Petroleum Gas Facilities and Piping.
1213.0 Pressure Testing and Inspection.
1213.1 Piping Installations.
1213.1.1 Inspection Requirements.
1213.1.2 Repairs and Additions.
1213.1.3 New Branches.
1213.1.4 Piping System.
1213.1.5 Regulators and Valves.
1213.1.6 Test Medium.
1213.2 Test Preparation.
1213.2.1 Pipe Joints.
Figure 1212.8 Method of Installing a Tee Fitting Sediment Trap
211 1213.2.2 Expansion Joints.
1213.2.3 Appliances and Equipment.
1213.2.4 Designed for (less than) Operating Pressures.
1213.2.5 Designed for (equal to or more than) Operating Pressures.
1213.2.6 Safety.
1213.3 Test Pressure.
1213.4 Detection of Leaks and Defects.
1213.4.1 Detecting Leaks.
1213.4.2 Repair or Replace.
1213.5 Piping System Leak Test.
1213.5.1 Turning Gas On.
1213.5.2 Leak Check.
1213.5.3 Placing Appliances and Equipment in Operation.
1213.6 Purging Requirements.
1213.6.1 Piping Systems Required to be Purged Outdoors.
1213.6.1.1 Removal from Service.
Table 1213.6.1 Size and Length of Piping
212 1213.6.1.2 Placing in Operation.
1213.6.1.3 Outdoor Discharge of Purged Gases.
1213.6.1.4 Combustible Gas Indicator.
1213.6.2 Piping Systems Allowed to be Purged Indoors or Outdoors.
1213.6.2.1 Purging Procedure.
1213.6.2.2 Combustible Gas Detector.
1213.6.3 Purging Appliances and Equipment.
1214.0 Interconnections Between Gas Piping Systems.
1214.1 Interconnections Supplying Separate Users.
1214.2 Interconnections for Standby Fuels.
1215.0 Required Gas Supply.
1215.1 General.
1215.2 Volume.
213 1215.3 Gas Appliances.
1215.4 Size of Piping Outlets.
1216.0 Required Gas Piping Size.
1216.1 Pipe Sizing Methods.
1216.1.1 Longest Length Method.
1216.1.2 Branch Length Method.
1216.1.3 Hybrid Pressure.
1216.2 Tables for Sizing Gas Piping Systems.
1216.3 Sizing Equations.
1216.4 Sizing of Piping Sections.
Table 1216.3 Cr and Y for Natural Gas and Undiluted Propane at Standard Conditions
214 1216.5 Engineering Methods.
1216.6 Variable Gas Pressure.
215 Figure 1216.1.1 Example Illustrating Use of Table 1208.4.1 and Table 1216.2(1)
216 Table 1216.2(1) Schedule 40 Metallic Pipe
217 Table 1216.2(2) Schedule 40 Metallic Pipe
218 Table 1216.2(3) Schedule 40 Metallic Pipe
219 Table 1216.2(4) Schedule 40 Metallic Pipe
220 Table 1216.2(5) Schedule 40 Metallic Pipe
221 Table 1216.2(6) Schedule 40 Metallic Pipe
222 Table 1216.2(7) Semi-Rigid Copper Tubing
223 Table 1216.2(8) Semi-Rigid Copper Tubing
224 Table 1216.2(9) Semi-Rigid Copper Tubing
225 Table 1216.2(10) Semi-Rigid Copper Tubing
226 Table 1216.2(11) Semi-Rigid Copper Tubing
227 Table 1216.2(12) Semi-Rigid Copper Tubing
228 Table 1216.2(13) Semi-Rigid Copper Tubing
229 Table 1216.2(14) Corrugated Stainless Steel Tubing (CSST)
230 Table 1216.2(15) Corrugated Stainless Steel Tubing (CSST)
231 Table 1216.2(16) Corrugated Stainless Steel Tubing (CSST)
232 Table 1216.2(17)Corrugated Stainless Steel Tubing (CSST)
233 Table 1216.2(18) Corrugated Stainless Steel Tubing (CSST)
234 Table 1216.2(19) Polyethylene Plastic Pipe
235 Table 1216.2(20) Polyethylene Plastic Pipe
236 Table 1216.2(21) Polyethylene Plastic Pipe
237 Table 1216.2(22) Polyethylene Plastic Tubing
Table 1216.2(23) Polyethylene Plastic Tubing
238 Table 1216.2(24) Schedule 40 Metallic Pipe
239 Table 1216.2(25) Schedule 40 Metallic Pipe
240 Table 1216.2(26) Schedule 40 Metallic Pipe
241 Table 1216.2(27) Schedule 40 Metallic Pipe
242 Table 1216.2(28) Semi-Rigid Copper Tubing
243 Table 1216.2(29) Semi-Rigid Copper Tubing
244 Table 1216.2(30) Semi-Rigid Copper Tubing
245 Table 1216.2(31) Corrugated Stainless Steel Tubing (CSST)
246 Table 1216.2(32) Corrugated Stainless Steel Tubing (CSST)
247 Table 1216.2(33) Corrugated Stainless Steel Tubing (CSST)
248 Table 1216.2(34) Polyethylene Plastic Pipe
249 Table 1216.2(35) Polyethylene Plastic Pipe
250 Table 1216.2(36) Polyethylene Plastic Tubing
252 Chapter 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems
Part I – General Requirements.
1301.0 General.
1301.1 Applicability.
1301.2 Where Not Applicable.
1301.3 Conflict of Requirements.
1301.4 Terms.
1301.5 Where Required.
1301.6 Existing Systems.
1302.0 Design Requirements.
1302.1 Building System Categories.
1302.2 Patient Care Rooms.
1302.3 Anesthetizing Locations.
1302.4 Wet Procedure Locations.
1303.0 Health Care Facilities.
1303.1 Drinking Fountain Control Valves.
1303.2 Psychiatric Patient Rooms.
1303.3 Locations for Ice Storage.
1303.4 Sterilizers and Bedpan Steamers.
TABLES
253 1303.4.1 Drainage Connections.
1303.4.2 Vapor Vents and Stacks.
1303.5 Aspirators.
1303.6 Drains.
1303.7 Clinical Sinks.
1303.7.1 Drainage Connection.
1303.8 Water Supply for Hospitals.
1304.0 Medical Gas and Medical Vacuum Piping Systems.
1304.1 General.
1304.2 Manufacturer’s Instructions.
1304.3 Supply Source.
1304.4 Certification of Systems.
1304.5 Construction Documents.
1304.5.1 Requirements.
1304.5.2 Extent of Work.
1304.5.3 Record.
1305.0 System Performance.
1305.1 Required Operating Pressures.
1305.2 Minimum Flow Rates.
1305.3 Minimum Station Outlets and Inlets.
254 1306.0 Qualifications of Installers.
1306.1 General.
1306.2 Brazing.
1306.2.1 Documentation.
Table 1305.1 Standard Designation Colors and Operating Pressures for Medical Gas and Medical Vacuum Systems
Table 1305.2 Minimum Flow Rates (cubic feet per minute)
255 1306.3 Health Care Organization Personnel.
1307.0 Brazing Procedures.
1307.1 General.
1307.2 Examination.
1307.3 Brazing Procedure Specification.
1307.4 Documentation.
1307.5 Procedures.
1307.6 Conditions of Acceptance.
1307.7 Qualifications.
Table 1305.3 Minimum Outlets and Inlets per Station
256 Part II – Medical Gas and Medical Vacuum System Piping.
1308.0 Pipe Materials.
1308.1 General.
1308.2 Cleaning.
1308.3 Delivery.
1308.4 Tubes for Medical Gas Systems.
1308.5 Tubes for Medical Vacuum Systems.
1309.0 Joints and Connections.
1309.1 General.
1309.2 Changes in Direction.
1309.2.1 Medical Vacuum Systems.
1309.3 Brazed Joints and Fittings.
257 1309.3.1 Tube Joints.
1309.3.2 Filler Metals.
1309.3.3 Copper-to-Copper Joints.
1309.3.4 Accessible.
1309.3.5 Tube Ends.
1309.3.5.1 Cutting Wheels.
1309.3.5.2 Cut Ends.
1309.3.6 Cleaning Procedures.
1309.3.6.1 Exterior Surfaces.
1309.3.6.2 Interior Surfaces.
1309.3.6.3 Abrasive Pads.
1309.3.6.4 Prohibited.
1309.3.6.5 Wiped.
1309.3.6.6 Examination.
1309.3.6.7 On-Site Recleaning.
1309.3.6.8 Contamination.
1309.3.6.9 Timeframe for Brazing.
1309.3.7 Brazing Dissimilar Metals.
1309.3.7.1 Surface Cleaning.
1309.3.7.2 Flux.
1309.3.7.3 Short Sections of Copper.
1309.3.7.4 Flux-Coated Brazing Rods.
258 1309.3.8 Nitrogen Purge.
1309.3.8.1 Source.
1309.3.8.2 Flow Rate Control.
1309.3.8.3 Oxygen Analyzer.
1309.3.8.4 During Installation.
1309.3.8.5 Discharge Opening.
1309.3.8.6 Temperature of Joint.
1309.3.8.7 Opening to be Sealed.
1309.3.8.8 Final Brazed Connection.
1309.3.8.9 Final Tie-In Test.
1309.3.8.10 Autogenous Orbital Welding Process.
1309.3.9 Assembling and Heating Brazed Joints.
1309.3.9.1 Heating of Joint.
1309.3.10 Inspection of Brazed Joints.
259 1309.3.10.1 Where Flux is Used.
1309.3.10.2 Visually Inspected.
1309.3.10.3 Prohibited Brazed Joints.
1309.3.10.4 Defective Brazed Joints.
1309.4 Special Fittings.
1309.4.1 Memory Metal Fittings.
1309.4.2 Axially Swaged Fittings.
1309.4.3 Threaded Fittings.
1309.4.4 Dielectric Fittings.
1309.4.5 Other Types of Fittings.
1309.5 Welded Joints.
1309.5.1 Qualifications.
1309.5.2 Welder Qualification Procedure.
1309.5.2.1 Purging of Joints.
260 1309.5.2.2 Test Coupons.
1309.5.3 Welding for Stainless Tube.
1309.6 Prohibited Joints.
1310.0 Installation of Piping.
1310.1 General.
1310.2 Required Pipe Sizing.
1310.2.1 Maximum Demand.
1310.2.2 Sizing Procedures.
Table 1310.2.1(1) System Sizing – Flow Requirements for Station Outlets and Inlets
261 1310.2.3 Engineering Methods.
1310.3 Pipe Protection.
1310.3.1 Exposed Piping.
1310.3.2 Underground Piping.
1310.3.3 Frost Protection.
1310.4 Location of Piping.
1310.4.1 Prohibited Locations.
1310.4.2 Approved Locations.
1310.5 Pipe Support.
1310.5.1 Hangers and Supports.
1310.5.2 Copper Tube.
1310.5.3 Damp Locations.
1310.5.4 Maximum Spacing.
1310.5.5 Seismic Provisions.
Table 1310.2.2(1) Maximum Permitted Pressure Loss in Medical Gas and Medical Vacuum Systems
Table 1310.5.4(1) Maximum Metallic Pipe Support Spacing
262 1310.6 Backfilling and Trenching.
1310.6.1 Conduit, Cover, or Enclosure.
1310.6.2 Excessive Stresses.
1310.6.3 Minimum Backfill.
1310.6.4 Trenches.
1310.6.5 Composition of Backfill.
1310.6.6 Marker.
1310.6.7 Warning.
1310.6.8 Wall Sleeve.
1310.7 Connectors.
1310.7.1 Flexible Connectors.
1310.7.2 Metallic Flexible Joints.
1310.8 Prohibited System Interconnections.
1310.8.1 Leak Testing.
1310.9 Changes in System Use.
1310.9.1 Medical Vacuum System.
Table 1310.5.4(2) Maximum Plastic Pipe Support Spacing
263 Table 1310.2.1(2) Pressure Loss for Medical Air
Table 1310.2.1(3) Pressure Loss for Nitrogen
264 Table 1310.2.1(4) Pressure Loss for Nitrous Oxide and Carbon Dioxide
Table 1310.2.1(5) Pressure Loss for Oxygen
265 Table 1310.2.1(6) Pressure Loss for Vacuum
266 Table 1310.2.1(7) Pressure Loss for Vacuum (Category 3)
267 1310.10 Breaching or Penetrating Medical Gas Piping.
1310.11 Labeling and Identification.
1310.11.1 Pipe Labeling.
1310.11.2 Location of Pipe Labeling.
268 1311.0 Cleaning for Medical Gas Piping Systems.
1311.1 Cleaning.
1311.2 Contaminated Materials.
1312.0 Shutoff Valves.
1312.1 General.
1312.1.1 Location.
1312.1.2 Installation.
1312.1.3 Emergency Shutoff Valves.
1312.1.3.1 Remote Activated.
1312.1.4 Labeled.
1312.2 Source Valves.
1312.2.1 Location.
1312.3 Main Valves.
1312.3.1 Access.
1312.3.2 Location.
1312.4 Riser Valves.
1312.4.1 Location.
1312.5 Service Valves.
1312.5.1 Branch Piping.
269 1312.5.2 Location.
1312.6 Zone Valves.
1312.6.1 Readily Operable.
1312.6.2 Arrangement.
1312.6.3 Indicators.
1312.6.4 Location.
1312.6.4.1 Special Installations.
1312.7 In-Line Shutoff Valves.
1312.8 Future Piping.
1312.8.1 Downstream Piping.
1312.9 Identification.
1312.9.1 Nonstandard Operating Pressures.
1312.9.2 Labeling.
270 Part III – Systems, Equipment, and Components.
1313.0 Central Supply Systems.
1313.1 General.
1313.1.1 Materials.
1313.1.2 Pressure-Relief Valve Requirements.
1314.0 Medical Air Systems.
1314.1 Medical Air Compressors.
1314.1.1 Capacity.
1314.1.2 Required Components.
1314.1.2.1 Category 1 and 2 Systems.
1314.1.2.2 Category 3 Systems.
271 1314.1.3 Air Sources.
1314.1.3.1 Category 1 and 2 Systems.
1314.1.3.2 Category 3 Systems.
1314.1.4 Air Intakes.
1314.1.4.1 Location.
1314.1.4.2 Separate Compressors.
1314.1.4.3 Screening.
1314.2 Medical Air Receivers.
1314.2.1 Valves.
1315.0 Medical Vacuum System.
1315.1 General.
272 1315.2 Medical-Surgical Vacuum Sources.
1315.3 Vacuum Pumps.
1315.4 Vacuum Receivers.
1315.5 Vacuum Source Exhausts.
1315.5.1 Location.
1315.5.2 Screening.
1315.5.3 Dips and Loops.
1315.5.4 Multiple Pumps.
1316.0 Pressure-Regulating Equipment.
1316.1 Where Required.
1316.2 Pressure-Relief Valves.
1316.2.1 Venting.
1316.2.2 Design.
1316.2.3 Isolation.
1316.3 Pressure Gauges.
273 1317.0 Station Outlets and Inlets.
1317.1 General.
1317.2 Required Valves.
1317.2.1 Secondary Valve.
1317.3 Post Installation.
1317.4 Identification.
1318.0 Warning Systems.
1318.1 Category 1 and 2 Systems.
1318.2 Category 3 Systems.
274 1318.3 Components.
Part IV – Testing, Inspection, and Certification.
1319.0 Testing and Inspection.
1319.1 Where Required.
1319.2 Breached Systems.
1319.3 Reports.
1319.4 Initial Piping Blow Down.
1319.5 Initial Pressure Tests – Medical Gas and Medical Vacuum Systems.
1319.5.1 Shutoff Valve.
1319.5.2 Required Test Pressure.
1319.5.3 Leaks.
1319.6 Cross-Connection Tests – Medical Gas and Medical Vacuum Systems.
1319.6.1 Atmospheric Pressure.
1319.6.2 Sources of Test Gas.
1319.6.3 System to be Charged.
1319.6.4 Check Outlets and Inlets.
1319.6.5 Repeat Test.
1319.6.6 Identification of System.
275 1319.7 Standing Pressure Tests – Medical Gas Piping Systems.
1319.7.1 Time Frame for Testing.
1319.7.2 Source Valve.
1319.7.3 Length of Testing.
1319.7.4 Test Pressure.
1319.7.5 Conclusion of Test.
1319.7.6 Leaks.
1319.7.7 Proof of Testing.
1319.8 Standing Pressure Tests – Medical Vacuum Piping Systems.
1319.8.1 Timeframe for Testing.
1319.8.2 Length of Testing.
1319.8.3 Test Pressure.
1319.8.4 Disconnection of Testing Source.
1319.8.5 Conclusion of Test.
1319.8.6 Leaks.
1319.8.7 Proof of Testing.
1319.9 Purge Tests.
1319.9.1 Procedure.
1319.9.2 Location.
1319.10 Operational Pressure Test.
1319.10.1 Test Gas.
1319.10.2 Medical Gas Outlets.
1319.10.3 Medical-Surgical Vacuum Inlets.
1319.10.4 Oxygen and Medical Air Outlets.
276 1319.11 Medical Gas Concentration Test.
1319.12 System Verification.
1319.12.1 Test Gas.
1319.12.2 Approved Tester.
1320.0 System Certification.
1320.1 Certification.
1320.2 Certification Tests.
1320.3 Report Items.
Table 1319.11 Gas Concentrations
278 Chapter 14 Firestop Protection
1401.0 General.
1401.1 Applicability.
1402.0 Construction Documents.
1402.1 Penetrations.
1403.0 Installation.
1403.1 Materials.
1404.0 Combustible Piping Installations.
1404.1 General Requirements.
1404.2 Fire-Resistance Rating.
1404.3 Firestop Systems.
1404.4 Connections.
1404.5 Insulation and Coverings.
1404.6 Sleeves.
1405.0 Noncombustible Piping Installations.
1405.1 General Requirements.
1405.2 Fire-Resistance Rating.
1405.3 Firestop Systems.
279 1405.4 Connections.
1405.5 Unshielded Couplings.
1405.6 Sleeves.
1405.7 Insulation and Coverings.
1406.0 Required Inspection.
1406.1 General.
1406.2 Examination.
1406.3 Penetrations.
1406.4 Field Installations.
280 Chapter 15 Alternate Water Sources for Nonpotable Applications
1501.0 General.
1501.1 Applicability.
1501.1.1 Allowable Use of Alternate Water.
1501.2 System Design.
1501.3 Permit.
1501.4 Component Identification.
1501.5 Maintenance and Inspection.
1501.5.1 Frequency.
1501.5.2 Maintenance Log.
1501.5.3 Maintenance Responsibility.
1501.6 Operation and Maintenance Manual.
1501.7 Minimum Water Quality Requirements.
1501.8 Material Compatibility.
1501.9 System Controls.
1501.10 Commercial, Industrial, and Institutional Restroom Signs.
TABLES
FIGURE
281 1501.10.1 Equipment Room Signs.
1501.11 Inspection and Testing.
1501.11.1 Supply System Inspection and Test.
1501.11.2 Annual Cross-Connection Inspection and Testing.
1501.11.2.1 Visual System Inspection.
1501.11.2.2 Cross-Connection Test.
Table 1501.5 Minimum Alternate Water Source Testing, Inspection, and Maintenance Frequency
282 1501.11.2.3 Discovery of Cross-Connection.
1501.11.2.4 Annual Inspection.
1501.12 Separation Requirements.
1501.13 Abandonment.
1501.13.1 General.
1501.13.2 Underground Tank.
1501.14 Sizing.
1502.0 Gray Water Systems.
1502.1 General.
1502.2 System Requirements.
1502.2.1 Surge Capacity.
283 1502.2.2 Diversion.
1502.2.3 Backwater Valves.
1502.3 Connections to Potable and Reclaimed(Recycled) Water Systems.
1502.4 Location.
1502.5 Plot Plan Submission.
1502.6 Prohibited Location.
1502.7 Drawings and Specifications.
Table 1502.4 Location of Gray Water System
284 1502.8 Procedure for Estimating Gray Water Discharge.
1502.8.1 Single Family Dwellings and Multi-Family Dwellings.
1502.8.2 Commercial, Industrial, and Institutional Occupancies.
1502.9 Gray Water System Components.
1502.9.1 Surge Tanks.
285 1502.9.2 Gray Water Pipe and Fitting Materials.
1502.9.3 Subsoil Irrigation Field Materials.
1502.9.4 Subsurface Irrigation Field and Mulch Basin Supply Line Materials.
1502.9.5 Valves.
1502.9.6 Trap.
1502.9.7 Backwater Valve.
1502.10 Subsurface Irrigation System Zones.
1502.10.1 Required Area of Subsurface Irrigation Fields, Subsoil Irrigation Fields and Mulch Basins.
1502.10.2 Determination of Maximum Absorption Capacity.
1502.10.3 Groundwater Level.
1502.11 Subsurface and Subsoil Irrigation Field, and Mulch Basin Design and Construction.
1502.11.1 Subsurface Irrigation Field.
1502.11.1.1 Minimum Depth.
1502.11.1.2 Filter.
Table 1502.10 Design of Six Typical Soils
286 1502.11.1.3 Emitter Size.
1502.11.1.4 Number of Emitters.
1502.11.1.5 Controls.
1502.11.1.6 Maximum Pressure.
1502.11.2 Mulch Basin.
1502.11.2.1 Single Family and Multi-Family Dwellings.
1502.11.2.2 Size.
1502.11.2.3 Minimum Depth.
1502.11.2.4 Maintenance.
1502.11.3 Subsoil Irrigation Field.
1502.11.3.1 Minimum Pipe Size.
1502.11.3.2 Filter Material and Backfill.
1502.11.3.3 Subsoil Irrigation Field Construction.
Table 1502.11 Subsurface Irrigation Design Criteria for Six Typical Soils
Table 1502.11.3 Subsoil Irrigation Field Construction
287 1502.12 Gray Water System Color and Marking Information.
1502.13 Other Collection and Distribution Systems.
1502.13.1 Higher Requirements.
1502.14 Testing.
1502.15 Maintenance.
1503.0 Reclaimed (Recycled) Water Systems.
1503.1 General.
1503.2 Permit.
1503.2.1 Plumbing Plan Submission.
1503.3 System Changes.
1503.4 Connections to Potable or Reclaimed(Recycled) Water Systems.
1503.5 Initial Cross-Connection Test.
1503.6 Reclaimed (Recycled) Water System Materials.
1503.7 Reclaimed (Recycled) Water System Colorand Marking Information.
1503.8 Valves.
1503.9 Hose Bibbs.
1503.10 Required Appurtenances.
Figure 1503.9
288 1503.11 Same Trench as Potable Water Pipes.
1503.12 Signs.
1503.13 Inspection and Testing.
1504.0 On-Site Treated Nonpotable Water Systems.
1504.1 General.
1504.2 Plumbing Plan Submission.
1504.3 System Changes.
1504.4 Connections to Potable or Reclaimed(Recycled) Water Systems.
1504.5 Initial Cross-Connection Test.
1504.6 On-Site Treated Nonpotable Water System Materials.
1504.7 On-Site Treated Nonpotable Water Devices and Systems.
1504.8 On-Site Treated Nonpotable Water System Color and Marking Information.
1504.9 Valves.
1504.10 Design and Installation.
1504.10.1 Listing Terms and Installation Instructions.
1504.10.2 Minimum Water Quality.
1504.10.3 Deactivation and Drainage.
1504.10.4 Near Underground Potable Water Pipe.
289 1504.10.5 Required Filters.
1504.11 Signs.
1504.12 Inspection and Testing.
290 Chapter 16 Nonpotable Rainwater Catchment Systems
1601.0 General.
1601.1 Applicability.
1601.1.1 Allowable Use of Alternate Water.
1601.2 System Design.
1601.3 Permit.
1601.4 Component Identification.
1601.5 Maintenance and Inspection.
1601.5.1 Frequency.
TABLES
Table 1601.5 Minimum Alternate Water Source Testing, Inspection, and Maintenance Frequency
FIGURE
291 1601.5.2 Maintenance Log.
1601.5.3 Maintenance Responsibility.
1601.6 Operation and Maintenance Manual.
1601.7 Minimum Water Quality Requirements.
1601.8 Material Compatibility.
1601.9 System Controls.
1601.10 Separation Requirements.
1601.11 Abandonment.
1601.11.1 General.
1601.11.2 Underground Tank.
1601.12 Sizing.
1602.0 Nonpotable Rainwater Catchment Systems.
1602.1 General.
1602.2 Plumbing Plan Submission.
1602.3 System Changes.
1602.4 Connections to Potable or Reclaimed (Recycled) Water Systems.
1602.5 Initial Cross-Connection Test.
292 1602.6 Sizing.
1602.7 Rainwater Catchment System Materials.
1602.7.1 Water Supply and Distribution Materials.
1602.7.2 Rainwater Catchment System Drainage Materials.
1602.7.3 Storage Tanks.
1602.7.4 Collections Surfaces.
1602.8 Rainwater Catchment System Color and Marking Information.
1602.9 Design and Installation.
1602.9.1 Outside Hose Bibbs.
1602.9.2 Deactivation and Drainage for Cross-Connection Test.
1602.9.3 Rainwater Catchment System Surfaces.
1602.9.3.1 Other Surfaces.
1602.9.3.2 Prohibited Discharges.
1602.9.4 Minimum Water Quality.
1602.9.5 Rainwater Storage Tanks.
1602.9.5.1 Construction.
1602.9.5.2 Location.
1602.9.5.3 Above Grade.
1602.9.5.4 Below Grade.
Figure 1602.9
293 1602.9.5.5 Drainage and Overflow.
1602.9.5.5.1 Overflow Outlet Size.
1602.9.5.6 Opening and Access Protection.
1602.9.5.7 Marking.
1602.9.5.8 Storage Tank Venting.
1602.9.6 Pumps.
1602.9.7 Roof Drains.
1602.9.8 Water Quality Devices and Equipment.
Table 1602.9.4 Minimum Water Quality
294 1602.9.9 Freeze Protection.
1602.9.10 Debris Removal.
1602.9.11 Required Filters.
1602.9.12 Roof Gutters.
1602.10 Signs.
1602.10.1 Commercial, Industrial, and Institutional Restroom Signs.
1602.10.2 Equipment Room Signs.
1602.11 Inspection and Testing.
1602.11.1 Supply System Inspection and Test.
1602.11.2 Annual Cross-Connection Inspection and Testing.
1602.11.2.1 Visual System Inspection.
1602.11.2.2 Cross-Connection Test.
295 1602.11.2.3 Discovery of Cross-Connection.
1602.11.2.4 Annual Inspection.
296 Chapter 17 Referenced Standards
1701.0 General.
1701.1 Standards.
TABLE
Table 1701.1 Referenced Standards
319 Abbreviations in Table 1701.1
320 Appendices Table of Contents
322 Appendix A Recommended Rules for Sizing the Water Supply System
A 101.0 General.
A 101.1 Applicability.
A 102.0 Preliminary Information.
A 102.1 Daily Service Pressure.
A 102.2 Water Meter.
A 102.3 Local Information.
A 103.0 Demand Load.
A 103.1 Supply Demand.
A 103.2 Continuous Supply Demand.
A 104.0 Permissible Friction Loss.
A 104.1 Residual Pressure.
TABLES
CHARTS
Chart A 102.2 Friction Losses for Disk-Type Water Meters
323 A 104.2 Elevation.
A 104.3 Available Pressure.
A 104.4 Developed Length.
A 105.0 Size of Building Supply.
A 105.1 Diameter.
A 105.2 Copper and Copper Alloy Piping.
A 105.3 Hard Water.
A 106.0 Size of Principal Branches and Risers.
A 106.1 Size.
A 106.2 Branches.
A 106.3 Water Closets.
A 107.0 General.
A 107.1 Velocities.
A 107.2 Pressure-Reducing Valves.
A 107.3 Fittings.
324 Table A 103.1 Water Supply Fixture Units (WSFU) and Minimum Fixture Branch Pipe Sizes
325 Chart A 103.1(1) Estimate Curves for Demand Load
Chart A 103.1(2) Enlarged Scale Demand Load
326 Table A 104.4 Allowance in Equivalent Length of Pipe for Friction Loss in Valves and Threaded Fittings* Equivalent Length of Pipe for Various Fittings
327 Chart A 105.1(1)
328 Chart A 105.1(2)
329 Chart A 105.1(3)
330 Chart A 105.1(4)
331 A 108.0 Sizing.
A 108.1 Example.
332 Appendix B Explanatory Notes on Combination Waste and Vent Systems
B 101.0 General.
B 101.1 Applicability.
B 101.2 General Requirements.
B 101.3 Caution.
B 101.4 Pneumatics.
B 101.5 Trap Sizes.
B 101.6 Layout Drawings.
B 101.6.1 Example of Sizing.
334 Appendix C Alternate Plumbing Systems
C 101.0 General.
C 101.1 Applicability.
C 101.2 Provisions.
C 101.3 Authority Having Jurisdiction.
C 101.4 Standards and Specifications.
C 101.5 Alternate Materials and Equipment.
C 201.0 Definitions.
C 201.1 General.
C 301.0 Engineered Plumbing Systems.
C 301.1 Inspection and Installation.
C 301.2 Owner Information.
C 302.0 Water Heat Exchangers.
C 302.1 Protection from Contamination.
C 302.2 Single-Wall Heat Exchangers.
C 302.3 Alternate Designs.
C 303.0 Fixture Unit Values for Private or Private Use Bathroom Groups.
C 303.1 Fixtures.
C 303.2 Water Supply Fixture Unit Values.
C 303.3 Drainage Fixture Unit Values.
C 304.0 Drainage System Sizing.
C 304.1 Drainage Fixture Units.
TABLES
335 C 304.2 Size of Building Drain and Building Sewer.
C 304.3 Size of Horizontal Branch or Vertical Stack.
C 304.3.1 Horizontal Stack Offsets.
C 304.3.2 Vertical Stack Offsets.
C 304.4 Horizontal Stack Offset and Horizontal Branch Connections.
C 401.0 Vent System Sizing.
C 401.1 Size of Vents.
C 401.2 Vent Stack.
Table C 303.1(1) Water Supply Fixture Units (WSFU) for Bathroom Groups
336 C 401.3 Branch Vents.
C 401.4 Venting Horizontal Offsets.
C 401.4.1 Venting Upper Section.
C 401.4.2 Venting Lower Section.
C 501.0 Vacuum Drainage Systems.
C 501.1 General.
Table C 303.1(2) Drainage Fixture Unit Values (DFU) for Bathroom Groups
337 C 501.2 System Design.
Table C 304.2 Building Drains and Building Sewers
Table C 304.3 Horizontal Fixture Branches and Stacks
338 C 501.2.1 Vacuum Generating System.
C 501.2.2 Waste Collection Center or Storage Tanks.
C 501.2.3 Piping Network.
C 501.2.4 Vacuum Interface Valve.
C 501.2.5 Control Components.
Table C 401.1 Size and Length of Vents
339 C 501.3 Fixtures.
C 501.4 Drainage Fixture Units.
C 501.5 Water Supply Fixture Units.
C 501.6 Materials.
C 501.7 Traps and Cleanouts.
C 501.8 Testing.
C 501.9 Manufacturer’s Instructions.
C 601.0 Single-Stack Vent System.
C 601.1 Where Permitted.
C 601.2 Stack Size.
C 601.2.1 Stack Vent.
C 601.3 Branch Size.
C 601.4 Length of Horizontal Branches.
C 601.4.1 Other Fixtures.
C 601.4.2 Length of Vertical Piping.
C 601.5 Maximum Vertical Drops from Fixtures.
C 601.6 Additional Venting Required.
340 C 601.7 Stack Offsets.
C 601.8 Separate Stack Required.
C 601.9 Sizing Building Drains and Sewers.
Table C 601.2 Single Stack Size
342 Appendix D Sizing Storm Water Drainage Systems
D 101.0 General.
D 101.1 Applicability.
D 102.0 Sizing by Flow Rate.
D 102.1 General.
D 103.0 Sizing by Roof Area.
D 103.1 General.
D 104.0 Capacity of Rectangular Scuppers.
D 104.1 General.
TABLES
Table D 101.1 Maximum Rates of Rainfall for Various Cities
348 Table D 104.1 Discharge from Rectangular Scuppers (gallons per minute)
350 Appendix E Manufactured/Mobile Home Parks and Recreational Vehicle Parks
E 101.0 Manufactured/Mobile Home (M/H) Park.
E 101.1 Applicability.
E 101.2 Definitions.
E 102.0 Construction Documents.
E 102.1 General Requirements.
E 201.0 Manufactured/Mobile Home Park Drainage System Construction.
E 201.1 Drainage Systems.
E 202.0 Materials.
E 202.1 General.
E 203.0 Drainage (Sewage) Lines.
E 203.1 General.
E 204.0 M/H Lot Drainage Inlet and Lateral.
E 204.1 Size.
E 204.2 Lateral Line.
TABLES
351 E 204.3 Materials.
E 204.4 Inlet.
E 205.0 Location of Lot Drain Inlet.
E 205.1 General.
E 206.0 Pipe Size.
E 206.1 Inlet, System, and Lateral Sizing.
E 206.2 Engineered Design.
E 207.0 M/H Drain Connector.
E 207.1 General.
E 207.2 Grade and Gastightness.
E 301.0 M/H Park Water Supply.
E 301.1 Potable Water Supply.
E 302.0 Lot Service Outlet Size.
E 302.1 General.
E 303.0 Location of Water Service.
E 303.1 General.
E 304.0 Pressure.
E 304.1 General.
E 305.0 Water Distribution Piping.
E 305.1 General.
Table E 203.1(1) Drainage Pipe Diameter and Number of Fixture Units on Drainage System
Table E 203.1(2) Minimum Grade and Slope of Drainage Pipe
352 E 306.0 Shutoff Valve.
E 306.1 General.
E 307.0 Backflow Preventer.
E 307.1 General.
E 308.0 Pressure-Relief Valve.
E 308.1 General.
E 309.0 Mechanical Protection.
E 309.1 General.
E 310.0 M/H Water Connector.
E 310.1 General.
E 311.0 Water-Conditioning Equipment.
E 311.1 Permit Required.
E 311.2 Approval.
E 311.3 Installation.
E 312.0 Testing.
E 312.1 General.
E 401.0 Fuel Supply.
E 401.1 Fuel Gas Piping Systems.
E 401.2 Gas Supply Connections.
E 401.3 Location of Gas Supply Connection.
E 401.4 Recreational Vehicle Park Fuel Gas Equipment and Installations.
E 402.0 Single and Multiple Manufactured Home Site Fuel Supply Systems.
E 402.1 Underground Installations.
E 402.1.1 Open-Ended Gastight Conduit.
E 402.1.2 Requirements.
353 E 403.0 Manufactured Home Site Gas Shutoff Valve.
E 403.1 General.
E 404.0 Gas Meters.
E 404.1 Support of Meters.
E 404.2 Location of Meters.
E 404.3 Meter Shutoff Valve or Cock.
E 405.0 Cathodic Protection Requirements.
E 405.1 General.
E 406.0 Manufactured Home Community LP-Gas Supply Systems.
E 406.1 General.
E 407.0 Required Gas Supply.
E 407.1 General.
E 408.0 Gas Pipe Sizing and Pressure.
E 408.1 Size.
E 408.2 Pressure.
E 409.0 Gas Piping Materials.
E 409.1 Metal.
354 E 409.2 Protection Coatings for Metal Gas Piping.
E 409.3 Plastic.
E 410.0 Gas Piping Installations.
E 410.1 Minimum Burial Below Ground Level and Clearances.
E 410.2 Metallic Gas Piping.
E 410.2.1 Cathodic Protection.
E 410.2.2 Underground Metallic Systems.
E 410.3 Plastic Gas Piping.
E 410.4 Gas Piping System Shutoff Valve.
E 411.0 Liquefied Petroleum Gas Equipment.
E 411.1 General.
E 412.0 Oil Supply.
E 412.1 General.
E 412.2 Minimum Oil Supply Tank Size.
E 412.3 Oil Supply Connections.
Table E 407.1 Demand Factors for Use in Calculating Gas Piping Systems in M/H Communities
355 E 413.0 Fuel Supply Systems Installation.
E 413.1 Flexible Gas Connector.
E 413.2 Use of Approved Pipe and Fittings of Extension.
E 413.3 Mechanical Protection.
E 413.4 Special Rules on Atmospherically Controlled Regulators.
E 413.5 Fuel Gas Piping Test.
E 413.5.1 Procedures.
E 413.5.2 Warning.
E 413.5.3 Vents.
356 E 413.6 Oil Tanks.
E 413.6.1 Installation.
E 413.6.2 Capacity.
E 413.6.3 Location.
E 413.6.4 Vent.
E 413.6.5 Liquid Level.
E 413.6.6 Fill Opening.
E 414.0 Manufactured Home Accessory Building Fuel Supply Systems.
E 414.1 General.
E 415.0 Community Building Fuel Supply Systems in Manufactured Home Communities.
E 415.1 Fuel Gas Piping and Equipment Installations.
E 415.2 Oil Supply Systems in M/H Communities.
E 415.3 Oil-Burning Equipment and Installation.
E 415.4 Inspections and Tests.
E 501.0 Recreational Vehicle Parks.
E 501.1 Plumbing Systems.
E 601.0 Recreational Vehicle Park Toilet and Shower Facilities.
E 601.1 Water Closets and Urinals.
E 602.0 Markings.
E 602.1 General.
E 603.0 Number of Water Closets.
E 603.1 General.
E 604.0 Interior Finish.
E 604.1 General.
357 E 605.0 Floors and Drains.
E 605.1 General.
E 606.0 Lavatories.
E 606.1 General.
E 607.0 Urinals.
E 607.1 General.
E 608.0 Approved Water Closets.
E 608.1 General.
E 609.0 Water Closet Compartment.
E 609.1 General.
E 610.0 Compartment Size.
E 610.1 General.
E 611.0 Receptacle.
E 611.1 General.
E 612.0 Shower Size.
E 612.1 General.
E 613.0 Drainage System Connection.
E 613.1 General.
E 614.0 Ceiling Height and Doors.
E 614.1 General.
E 615.0 Ventilation.
E 615.1 General.
E 701.0 Recreational Vehicle Park Potable Water Supply and Distribution.
E 701.1 Quality.
E 702.0 Sources.
E 702.1 General.
358 E 703.0 Prohibited Connections.
E 703.1 General.
E 704.0 Supply.
E 704.1 General.
E 705.0 Pressure and Volume.
E 705.1 General.
E 706.0 Outlets.
E 706.1 General.
E 707.0 Storage Tanks.
E 707.1 General.
E 801.0 Recreational Vehicle Park Water Connections for Individual Recreational Vehicles.
E 801.1 Location.
E 802.0 Water Riser Pipe.
E 802.1 General.
E 803.0 Drinking Fountains.
E 803.1 General.
E 901.0 Recreational Vehicle Park Drainage System.
E 901.1 Where Required.
E 902.0 Materials.
E 902.1 General.
E 903.0 Pipe Sizes.
E 903.1 General.
E 904.0 Sewer Lines.
E 904.1 General.
E 905.0 Cleanouts.
E 905.1 General.
E 1001.0 Recreational Vehicle Site Drainage System Inlet.
E 1001.1 Sewer Riser Pipe.
Table E 903.1 Pipe Sizes
359 E 1002.0 Location.
E 1002.1 General.
E 1003.0 Protection.
E 1003.1 General.
E 1101.0 Recreational Vehicle Park Sanitary Disposal Stations.
E 1101.1 Where Required.
E 1102.0 Access.
E 1102.1 General.
E 1103.0 Construction.
E 1103.1 General.
E 1104.0 Flushing Device.
E 1104.1 General.
E 1201.0 Recreational Vehicle Park Water Supply Stations.
E 1201.1 Potable Watering Stations.
360 Appendix F Firefighter Breathing Air Replenishment Systems
F 101.0 General.
F 101.1 Applicability.
F 201.0 Definitions.
F 201.1 General.
F 301.0 System Components.
F 301.1 General.
F 401.0 Required Installations.
F 401.1 General.
F 501.0 Exterior Fire Department Connection Panel and Enclosure.
F 501.1 Purpose.
F 501.2 Number of Panels.
F 501.3 Location.
F 501.4 Construction.
F 501.5 Vehicle Protection.
F 501.6 Enclosure Marking.
F 501.7 Enclosure Components.
361 F 501.8 Pressure-Relief Valve.
F 501.9 Security.
F 601.0 Interior Cylinder Fill Panels.
F 601.1 Cabinet Requirements.
F 601.2 Clearance and Access.
F 601.3 Door.
F 601.4 Cabinet Marking.
F 601.5 Cabinet Components.
F 601.5.1 Cylinder Fill Panel.
F 601.6 Cylinder Filling Hose.
F 601.7 Security.
F 701.0 Interior Cylinder Fill Stations and Enclosures.
F 701.1 Location.
F 701.2 Security.
F 701.3 Components.
F 701.4 Cylinder Filling Hose.
F 701.5 Enclosure and Air Filling Station Marking.
F 801.0 Materials.
F 801.1 General.
F 801.2 Tubing.
F 801.3 Fittings.
362 F 801.4 Prohibited Materials.
F 801.5 Pressure Monitoring Switch.
F 801.6 Isolation Valve.
F 901.0 System Requirements.
F 901.1 Protection.
F 901.2 Markings.
F 901.3 Tubing Markings.
F 901.4 Support.
F 1001.0 Design Criteria.
F 1001.1 Fill Time.
F 1001.2 Fill Panels or Stations Location.
F 1001.2.1 High-Rise Buildings.
F 1001.2.2 Underground Structures.
F 1001.2.3 Installation Locations.
F 1101.0 System Assembly Requirements.
F 1101.1 General.
F 1101.2 Welding Requirements.
363 F 1101.3 Prevention of Contamination.
F 1201.0 System Acceptance and Certification.
F 1201.1 Static Pressure Testing.
F 1201.2 Low Pressure Switch Test.
F 1201.3 Compatibility Check.
F 1201.4 Material Certifications.
F 1201.5 Air Sampling.
F 1201.5.1 Air Quality Analysis.
F 1201.6 Annual Air Sampling.
F 1201.7 Final Proof Test.
364 Appendix G Sizing of Venting Systems
G 101.0 General.
G 101.1 Applicability.
G 101.2 Examples Using Single Appliance Venting Tables.
TABLE
FIGURES
Figure G 101.2(1) Type B Double-Wall Vent System Serving a Single Appliance with a Type B Double-Wall Vent
Figure G 101.2(2) Type B Double-Wall Vent System Serving a Single Appliance with a Single-Wall Metal Vent Connector
Figure G 101.2(3) Vent System Serving a Single Appliance with a Masonry Chimney and a Type B Double-Wall Vent Connector
365 Figure G 101.2(4) Vent System Serving a Single Appliance Using a Masonry Chimney and a Single-Wall Metal Vent Connector
Figure G 101.2(5) Asbestos Cement Type B or Single-Wall Metal Vent System Serving a Single Draft Hood-Equipped Appliance
Figure G 101.2(6) Vent System Serving Two or More Appliances with Type B Double-Wall Vent and Type B Double-Wall Vent Connectors
Figure G 101.2(7) Vent System Serving Two or More Appliances with Type B Double-Wall Vent and Single-Wall Metal Vent Connectors
366 Figure G 101.2(8) Masonry Chimney Serving Two or More Appliances with Type B Double-Wall Vent Connectors
Figure G 101.2(9) Masonry Chimney Serving Two or More Appliances with Single-Wall Metal Vent Connectors
Figure G 101.2(10) Asbestos Cement Type B or Single-Wall Metal Vent Systems Serving Two or More Draft Hood-Equipped Appliances
Figure G 101.2(11) Use of Manifolded Common Vent Connectors
367 G 101.3 Example 1: Single Draft Hood-Equipped Appliance.
Figure G 101.2(12) Use of Offset Common Vent
Figure G 101.2(13) Multistory Gas Vent Design Procedure for Each Segment of System
Figure G 101.2(14) Principles of Design of Multistory Vents Using Vent Connector and Common Vent Design Tables
368 G 101.4 Example 2: Single Fan-Assisted Appliance.
G 101.5 Example 3: Interpolating Between Table Values.
Figure G 101.3 Single Draft Hood-Equipped Appliance – Example 1
Figure G 101.4 Single Fan-Assisted Appliance – Example 2
369 G 101.6 Example 4: Common Venting Two Draft Hood-Equipped Appliances.
G 101.7 Example 5(a): Common Venting a Draft Hood-Equipped Water Heater with a Fan-Assisted Furnace into a Type B Vent.
Figure G 101.6 Common Venting Two Draft Hood-Equipped Appliances – Example 4
370 G 101.8 Example 5(b): Common Venting into an Interior Masonry Chimney.
Figure G 101.7 Common Venting a Draft Hood-Equipped Water Heater with a Fan-Assisted Furnace into a Type B Double-Wall Common Vent – Example 5(a)
371 G 101.9 Example 5(c): Common Venting into an Exterior Masonry Chimney.
Table G 101.8 Masonry Chimney Liner Dimensions with Circular Equivalents
374 Appendix H Private Sewage Disposal Systems
H 101.0 General.
H 101.1 Applicability.
H 101.2 General Requirements.
H 101.3 Quantity and Quality.
H 101.4 Septic Tank and Disposal Field Systems.
H 101.5 Flood Hazard Areas.
H 101.6 Design.
H 101.7 Capacity.
H 101.8 Location.
H 101.9 Building Permit.
H 101.10 Additional Requirements.
H 101.11 Alternate Systems.
TABLES
CHART
375 H 201.0 Capacity of Septic Tanks.
H 201.1 General.
H 301.0 Area of Disposal Fields and Seepage Pits.
H 301.1 General.
Table H 101.8 Location of Sewage Disposal System
376 Table H 201.1(1) Capacity of Septic Tanks
Table H 201.1(2) Estimated Waste/Sewage Flow Rates
377 Table H 201.1(3) Design Criteria of Five Typical Soils
378 H 401.0 Percolation Test.
H 401.1 Pit Sizes.
H 401.2 Absorption Qualities.
H 401.3 Absorption Rates.
H 501.0 Septic Tank Construction.
H 501.1 Plans.
H 501.2 Design.
H 501.3 Construction.
H 501.4 Compartments.
H 501.5 Access.
Table H 201.1(4) Leaching Area Size Based on Septic Tank Capacity
379 H 501.6 Pipe Opening Sizes.
H 501.7 Pipe Extension.
H 501.8 Free Vent Area.
H 501.9 Sidewalls.
H 501.10 Partitions and Baffles.
H 501.11 Structural Design.
H 501.12 Manholes.
H 501.13 Materials.
H 501.14 Prefabricated Septic Tanks.
H 601.0 Disposal Fields.
H 601.1 Distribution Lines.
H 601.2 Filter Material.
H 601.3 Grade Board.
380 H 601.4 Seepage Pits.
H 601.5 Distribution Boxes.
H 601.6 Laterals.
H 601.7 Connections.
H 601.8 Dosing Tanks.
H 601.9 Construction.
H 601.10 Joints.
H 701.0 Seepage Pits.
H 701.1 Capacity.
H 701.2 Multiple Installations.
H 701.3 Construction.
H 701.4 Lining.
Table H 601.9 General Disposal Field Requirements
381 H 701.5 Brick and Block.
H 701.6 Sidewall.
H 701.7 Arch and Dome.
H 701.8 Location.
H 701.9 Inlet Fitting.
H 801.0 Cesspools.
H 801.1 Limitations.
H 801.2 Septic Tanks.
H 801.3 Construction.
H 801.4 Existing Installations.
H 901.0 Commercial or Industrial Special Liquid-Waste Disposal.
H 901.1 Interceptor.
H 901.2 Installation.
H 901.3 Sampling Box.
H 901.4 Design and Structural Requirement.
H 901.5 Location.
H 901.6 Waste Discharge.
H 901.7 Design Criteria.
H 1001.0 Inspection and Testing.
H 1001.1 Inspection.
382 H 1001.2 Testing.
H 1101.0 Abandoned Sewers and Sewage Disposal Facilities.
H 1101.1 Plugged and Capped.
H 1101.2 Fill Material.
H 1101.3 Filling Requirements.
H 1101.4 Owner.
H 1101.5 Permittee.
H 1201.0 Drawings and Specifications.
H 1201.1 General.
Chart H 901.7 Recommended Design Criteria
384 Appendix I Installation Standard
1.0 Scope.
1.1 General.
1.1.1 This Standard specifies requirements for the installation of SDR 9 CTS crosslinked polyethylene (PEX) tubing and fittings, including cold-expansion, crimp, press, and mechanical compression fittings, intended for hot- and cold-water distribution systems within buildings.
1.1.2 This Standards applies to (a) SDR 9 CTS PEX tubing complying with ASTM F876 and pressure-rated in accordance with PPI TR-3; and (b) PEX fitting systems complying with (i) ASTM F877, for mechanical compression fittings and metal or plastic insert fittings with stainless steel press sleeves; (ii) ASTM F1807 or ASTM F2159, for metal or plastic insert fittings with copper crimp rings; (iii) ASTM F1960, for cold expansion fittings with PEX reinforced rings; or (iv) ASTM F2080, for cold expansion fittings with metal compression sleeves.
1.2 Terminology.
1.3 Amendments.
2.0 Reference Publications.
TABLES
FIGURES
385 3.0 Abbreviations.
4.0 General.
4.1 Tubing.
4.1.1 PEX tubing can be (a) pigmented throughout (i.e., with color); (b) non-pigmented (e.g., translucent or natural); or (c) coated with a pigmented layer.
4.1.2 PEX tubing is typically available in NTS-1/4 to NTS-3.
4.1.3 Before installation, the installer shall review the tubing markings and verify that (a) the standard designation(s) of the fittings to which the tube can be joined to is included in the markings; (b) it bears a certification mark from an accredited certification organization; and (c) pressure and temperature ratings meet or exceed that of the intended end-use.
4.2 Fittings.
4.2.1 Cold-Expansion Fittings.
4.2.2 Crimp or Press Insert Fittings.
4.2.3 Compression Fittings.
4.3 Installation.
4.4 Tools.
4.5 Tubing Protection.
4.5.1 Abrasion.
4.5.2 Puncture.
5.0 Handling.
5.1 Receiving.
386 5.2 Storage and UV Exposure.
5.2.1 PEX tubing and fittings shall be stored indoors and in its original packaging until the time of installation.
5.2.2 Accumulative exposure time to UV radiation during storage and installation shall not exceed the UV exposure limits recommended by the manufacturer or specified in ASTM F876.
5.3 Exposure to Heat.
5.3.1 PEX tubing and fittings shall not be exposed to open flames.
5.3.2 PEX tubing shall not be exposed to temperatures exceeding 93ºC (200ºF).
5.4 Exposure to Chemicals.
5.4.1 Chemical compatibility (e.g., with common construction materials) shall be verified with the manufacturer prior to direct contact.
5.4.2 In general, petroleum- or solvent-based chemicals (e.g., paints, greases, pesticides, or sealants) shall not be allowed to come indirect contact with PEX tubing or fittings.
6.0 Thermal Expansion and Contraction.
6.1 Horizontal Tubing Runs.
6.2 Vertical Tubing Runs.
6.3 Clearance.
6.4 Expansion Arms and Expansion Loops.
6.4.1 Expansion Arms (See Figure 1).
6.4.1.1 Expansion arms shall be installed as illustrated in Figure 1.
387 6.4.1.2 The minimum length of expansion arms shall be calculated using the following equation:
6.4.2 Expansion Loops (See Figure 2).
6.4.2.1 Expansion loops shall be installed at the midpoint between anchors, as illustrated in Figure 2.
6.4.2.2 The minimum length of expansion loops shall be calculated using the equation in Section 6.4.1.2; however, the distance LB shall be divided into three sections, as illustrated in Figure 2, where L1 = LB ÷ 5; and L2 = L1 × 2
7.0 Hangers and Supports.
7.1 Vertical Tubing.
7.2 Horizontal Tubing.
7.3 Anchors.
8.0 Joints and Connections.
8.1 Assembly Procedure.
8.2 Concealed Joints.
9.0 Clearances.
9.1 Gas Vents.
9.2 Recessed Light Fixtures.
9.3 Fluorescent Lighting.
10.0 Other Considerations.
10.1 Hot-Work Joints.
388 10.2 Bending Radius.
10.2.1 The free (unsupported) bending radius for PEX tubing, measured at the outside of the bend, shall be not less than six times the actual outside diameter of the tubing, unless otherwise specified by the PEX manufacturer.
10.2.2 Tighter bends may be used when the PEX tubing is uniformly bent (supported) around a curved bracket or other rigid fixture.
10.3 Directional Fittings.
10.4 Direct Burial.
10.5 Fire-Resistive Construction.
10.6 Sizing and Flow Velocities.
10.6.1 PEX tubing shall be sized in accordance with IAPMO/ANSI UPC 1.
10.6.2 The tubing manufacturer’s pressure-loss data should be referenced when using Appendix A of IAPMO/ANSI UPC 1.
10.6.3 Flow velocities through the water distribution system, used for calculating flush tank and flush valve fixture units depending on the tubing sizes (see Table 1), shall not exceed (a) 3.0 m/s (10 ft/s) for cold-water distribution systems; and (b) 2.4 m/s (8 ft/s) for hot-water distribution systems.
10.6.4 Hot-water recirculation systems shall (a) be balanced to maintain adequate system temperatures; and (b) have flow velocities that do not exceed 0.6 m/s (2 ft/s) (see Table 2); and (c) use only PEX tubing designated for hot, chlorinated water recirculation systems and rated for the maximum percentage of time during which the system is intended to be operated at elevated temperatures, in accordance with ASTM F876.
10.7 Installation Testing.
Figure 1 Expansion Arms
389 Table 1 Calculation of Flush Tank and Flush Valve Fixture Units
Table 2 Tubing Sizes, Flows, and Friction Losses for Hot-Water Recirculation Systems
Figure 2 Expansion Loops
390 Figure 3 Pressure Loss of PEX Tubing at 16 ºC (60ºF)
391 Figure 4 Pressure Loss of PEX Tubing at 49 ºC (120ºF)
392 Appendix J Combination of Indoor and Outdoor Combustion and Ventilation Opening Design
J 101.0 General.
J 101.1 Applicability.
J 101.2 Example of Combination Indoor and Outdoor Combustion Air Opening.
TABLE
393 Table J 101.2 Standard Method: Required Volume, All Appliances
394 Appendix K Potable Rainwater Catchment Systems
K 101.0 General.
K 101.1 Applicability.
K 101.2 System Design.
K 101.3 Permit.
K 101.3.1 Plumbing Plan Submission.
K 101.3.2 System Changes.
K 101.4 Product and Material Approval.
K 101.4.1 Plumbing Materials and Systems.
K 101.5 Maintenance and Inspection.
K 101.5.1 Frequency.
K 101.5.2 Maintenance Log.
K 101.5.3 Maintenance Responsibility.
K 101.6 Operation and Maintenance Manual.
K 101.7 Minimum Water Quality Requirements.
K 101.8 Material Compatibility.
K 101.9 System Controls.
K 102.0 Connection.
K 102.1 General.
TABLES
395 K 102.2 Connections to Public or Private Potable Water Systems.
K 102.3 Backflow Prevention.
K 103.0 Potable Rainfall Catchment System Materials.
K 103.1 Collections Surfaces.
K 103.1.1 Prohibited.
K 103.2 Rainwater Catchment System Drainage Materials.
K 103.3 Storage Tanks.
K 103.4 Water Supply and Distribution Materials.
K 104.0 Design and Installation.
K 104.1 Collection Surfaces.
K 104.1.1 Prohibited Discharges.
K 104.2 Minimum Water Quality.
Table K 101.5 Minimum Potable Rainwater Catchment System Testing, Inspection, and Maintenance Frequency
396 K 104.2.1 Filtration Devices.
K 104.2.2 Disinfection Devices.
K 104.3 Overhanging Tree Branches and Vegetation.
K 104.4 Rainwater Storage Tanks.
K 104.4.1 Construction.
K 104.4.2 Location.
K 104.4.2.1 Above Grade.
K 104.4.2.2 Below Grade.
K 104.4.3 Drainage and Overflow.
K 104.4.3.1 Overflow Outlet Size.
K 104.4.4 Opening and Access Protection.
K 104.4.4.1 Animals and Insects.
Table K 104.2(1) Minimum Water Quality
Table K 104.2(2) Minimum System Maintenance Requirements
397 K 104.4.4.2 Human Access.
K 104.4.4.3 Exposure to Sunlight.
K 104.4.5 Inlets.
K 104.4.6 Primary Tank Outlets.
K 104.4.7 Storage Tank Venting.
K 104.5 Pumps.
K 104.6 Roof Drains.
K 104.7 Water Quality Devices and Equipment.
K 104.7.1 Filtration and Disinfection Systems.
K 104.8 Freeze Protection.
K 104.9 Roof Washer or Pre-Filtration System.
K 104.9.1 Size.
K 104.9.2 Debris Screen.
K 104.9.3 Drain Discharge.
K 104.9.4 Automatic Drain.
K 104.10 Filtration and Disinfection Systems.
K 104.11 Roof Gutters.
K 104.12 Drains, Conductors, and Leaders.
K 104.13 Size of Potable Water Piping.
K 105.0 Cleaning.
K 105.1 General.
K 106.0 Supply System Inspection and Test.
K 106.1 General.
400 Appendix L Sustainable Practices
L 101.0 General.
L 101.1 Applicability.
L 101.2 Definition of Terms.
L 201.0 Definitions.
TABLES
401 L 301.0 General Regulations.
L 301.1 Installation.
L 301.2 Qualifications.
L 302.0 Disposal of Liquid Waste.
L 302.1 Disposal.
L 302.2 Connections to Plumbing System Required.
L 303.0 Abandonment.
L 303.1 General.
L 401.0 Water Conservation and Efficiency.
L 401.1 Scope.
L 402.0 Water-Conserving Plumbing Fixtures and Fittings.
L 402.1 General.
L 402.2 Water Closets.
L 402.2.1 Gravity, Pressure Assisted, and Electro-Hydraulic Tank Type Water Closets.
402 L 402.2.2 Flushometer-Valve Activated Water Closets.
L 402.3 Urinals.
L 402.3.1 Nonwater Urinals.
L 402.4 Residential Kitchen Faucets.
L 402.5 Lavatory Faucets.
L 402.5.1 Lavatory Faucets in Residences, Apartments, and Private Bathrooms in Lodging Facilities, Hospitals, and Patient Care Facilities
L 402.5.2 Lavatory Faucets in Other Than Residences, Apartments, and Private Bathrooms in Lodging Facilities.
Table L 402.1 Maximum Fixture and Fixture Fittings Flow Rates
403 L 402.5.2.1 Maximum Flow Rate.
L 402.5.2.2 Metering Faucets.
L 402.6 Showerheads.
L 402.6.1 Multiple Showerheads Serving One Shower Compartment.
L 402.6.2 Bath and Shower Diverters.
L 402.6.3 Shower Valves.
L 402.7 Commercial Pre-Rinse Spray Valves.
L 402.8 Emergency Safety Showers and Eye Wash Stations.
L 402.9 Drinking Fountains.
L 403.0 Appliances.
L 403.1 Dishwashers.
L 403.2 Clothes Washers.
L 404.0 Occupancy Specific Water Efficiency Requirements.
L 404.1 Commercial Food Service.
L 404.2 Ice Makers.
L 404.3 Food Steamers.
L 404.4 Combination Ovens.
L 404.5 Grease Interceptors.
L 404.6 Dipper Well Faucets.
L 404.7 Medical and Laboratory Facilities.
L 404.8 Steam Sterilizers.
404 L 404.9 X-Ray Film Processing Units.
L 404.10 Exhaust Hood Liquid Scrubber Systems.
L 405.0 Leak Detection and Control.
L 405.1 General.
L 406.0 Fountains and Other Water Features.
L 406.1 Use of Alternate Water Source for Special Water Features.
L 407.0 Meters.
L 407.1 Required.
L 407.2 Consumption Data.
L 407.3 Access.
L 408.0 Condensate Recovery.
L 408.1 General.
L 409.0 Water-Powered Sump Pumps.
L 409.1 General.
L 410.0 Water Softeners and Treatment Devices.
L 410.1 Water Softeners.
L 410.2 Water Softener Limitations.
L 410.3 Point-of-Use Reverse Osmosis Water Treatment Systems.
L 411.0 Landscape Irrigation Systems.
L 411.1 General.
405 L 411.2 Backflow Protection.
L 411.3 Use of Alternate Water Sources for Landscape Irrigation.
L 411.4 Irrigation Control Systems.
L 411.5 Low Flow Irrigation.
L 411.6 Mulched Planting Areas.
L 411.7 System Performance Requirements.
L 411.8 Narrow or Irregularly Shaped Landscape Areas.
L 411.9 Sloped Areas.
L 411.10 Sprinkler Head Installations.
L 411.10.1 Sprinkler Heads in Common Irrigation Zones.
L 411.10.2 Sprinkler Head Pressure Regulation.
L 411.10.3 Pop-up Type Sprinkler Heads.
L 411.11 Irrigation Zone Performance Criteria.
406 L 411.12 Qualifications.
L 412.0 Trap Seal Protection.
L 412.1 Water Supplied Trap Primers.
L 412.2 Drainage Type Trap Seal Primer Devices.
L 413.0 Vehicle Wash Facilities.
L 413.1 General.
L 501.0 Alternate Water Sources.
L 501.1 Scope.
L 501.2 System Design.
L 501.3 Permit.
L 501.3.1 Plumbing Plan Submission.
L 501.3.2 System Changes.
L 501.4 Product and Material Approval.
L 501.4.1 Plumbing Materials and Systems.
L 501.5 Maintenance and Inspection.
L 501.5.1 Frequency.
L 501.5.2 Maintenance Log.
407 L 501.5.3 Maintenance Responsibility.
L 501.6 Operation and Maintenance Manual.
L 501.7 Minimum Water Quality Requirements.
L 501.8 Material Compatibility.
L 501.9 System Controls.
L 502.0 Connection.
L 502.1 General.
L 502.2 Connections to Public or Private Potable Water Systems.
L 502.3 Backflow Prevention.
L 503.0 Potable Rainfall Catchment System Materials.
L 503.1 Collections Surfaces.
Table L 501.5.1 Minimum Potable Rainwater Catchment System Testing, Inspection, and Maintenance Frequency
408 L 503.1.1 Prohibited.
L 503.2 Rainwater Catchment System Drainage Materials.
L 503.3 Storage Tanks.
L 503.4 Water Supply and Distribution Materials.
L 504.0 Design and Installation.
L 504.1 Collection Surfaces.
L 504.1.1 Prohibited Discharges.
L 504.2 Minimum Water Quality.
L 504.2.1 Filtration Devices.
L 504.2.2 Disinfection Devices.
L 504.3 Overhanging Tree Branches and Vegetation.
L 504.4 Rainwater Storage Tanks.
L 504.4.1 Construction.
L 504.4.2 Location.
L 504.4.2.1 Above Grade.
Table L 504.2(1) Minimum Water Quality
Table L 504.2(2) Minimum System Maintenance Requirements
409 L 504.4.2.2 Below Grade.
L 504.4.3 Drainage and Overflow.
L 504.4.3.1 Overflow Outlet Size.
L 504.4.4 Animals and Insects.
L 504.4.4.1 Human Access.
L 504.4.4.2 Exposure to Sunlight.
L 504.4.5 Inlets.
L 504.4.6 Primary Tank Outlets.
L 504.4.7 Storage Tank Venting.
L 504.5 Pumps.
L 504.6 Roof Drains.
L 504.7 Water Quality Devices and Equipment.
L 504.7.1 Filtration and Disinfection Systems.
L 504.8 Freeze Protection.
L 504.9 Roof Washer or Pre-Filtration System.
L 504.9.1 Size.
L 504.9.2 Debris Screen.
L 504.9.3 Drain Discharge.
410 L 504.9.4 Automatic Drain.
L 504.10 Filtration and Disinfection Systems.
L 504.11 Roof Gutters.
L 504.12 Drains, Conductors, and Leaders.
L 504.13 Size of Potable Water Piping.
L 505.0 Cleaning.
L 505.1 General.
L 506.0 Supply System Inspection and Test.
L 506.1 General.
L 601.0 Water Heating Design, Equipment, and Installation.
L 601.1 Scope.
L 601.2 Insulation.
L 601.3 Recirculation Systems.
L 601.3.1 For Low-Rise Residential Buildings.
L 601.3.2 For Pumps Between Boilers and Storage Tanks.
L 601.4 Recirculation Pump Controls.
L 601.5 Temperature Maintenance Controls.
411 L 601.6 System Balancing.
L 601.7 Flow Balancing Valves.
L 601.8 Air Elimination.
L 601.9 Gravity or Thermosyphon Systems.
L 602.0 Service Hot Water – Low-Rise Residential Buildings.
L 602.1 General.
L 602.2 Water Heaters and Storage Tanks.
L 602.3 Recirculation Systems.
L 602.4 Central Water Heating Equipment.
L 602.5 Insulation.
L 602.6 Hard Water.
L 602.7 Maximum Volume of Hot Water.
L 602.7.1 Maximum Volume of Hot Water Without Recirculation or Heat Trace.
L 602.7.2 Maximum Volume of Hot Water with Recirculation or Heat Trace.
L 602.7.3 Hot Water System Submeters.
Table L 602.7 Water Volume for Distribution Piping Materials
412 L 603.0 Service Hot Water – Other Than Low-Rise Residential Buildings.
L 603.1 General.
L 603.1.1 New Buildings.
L 603.1.2 Additions to Existing Buildings.
L 603.1.3 Alterations to Existing Buildings.
L 603.2 Compliance Path(s).
L 603.2.1 Energy Cost Budget Method.
L 603.3 Mandatory Provisions.
L 603.3.1 Load Calculations.
L 603.3.2 Equipment Efficiency.
L 603.3.3 Insulation.
L 603.3.4 Hot Water System Design.
L 603.3.4.1 Recirculation System.
L 603.3.4.2 Maximum Volume of Hot Water.
L 603.3.5 Service Water Heating System Controls.
413 Table L 603.3.2 Performance Requirements for Water Heating Equipment
414 L 603.3.5.1 Temperature Controls.
L 603.3.5.2 Outlet Temperature Controls.
L 603.3.6 Pools.
L 603.3.6.1 Pool Heaters.
L 603.3.6.2 Pool Covers.
L 603.3.6.3 Time Switches.
Table L 603.3.3 Minimum Pipe Insulation Thickness for Heating and Hot Water Systems (Steam, Steam Condensate, Hot Water Heating, and Domestic Water Systems)
415 L 603.3.7 Heat Traps.
L 603.4 Prescriptive Path.
L 603.4.1 Space Heating and Water Heating.
L 603.4.2 Service Water Heating Equipment.
L 603.4.2.1 Buildings with High-Capacity Service Water Heating Systems.
L 603.4.3 Heat Recovery for Service WaterHeating.
L 603.4.3.1 Capacity.
L 603.5 Submittals.
416 L 604.0 Solar Water Heating Systems.
L 604.1 General.
L 604.2 Annual Inspection and Maintenance.
L 605.0 Hard Water.
L 605.1 Softening and Treatment.
L 606.0 Drain Water Heat Exchangers.
L 606.1 General.
L 701.0 Installer Qualifications.
L 701.1 Scope.
L 702.0 Qualifications.
L 702.1 General.
L 801.0 Method of Calculating Water Savings.
L 801.1 Purpose.
L 801.2 Calculation of Water Savings.
417 Table L 801.2(1) Water Use Baseline
418 Table L 801.2(2) Water Savings Calculator
420 Index
IAPMO UPC 2015 1stPrinting
$66.08