Shopping Cart

No products in the cart.

ICC IBC 2018

$72.50

International Building Code

Published By Publication Date Number of Pages
ICC 2018 757
Guaranteed Safe Checkout
Category:

If you have any questions, feel free to reach out to our online customer service team by clicking on the bottom right corner. We’re here to assist you 24/7.
Email:[email protected]

The scope of the International Building Code® (IBC®) includes all buildings except detached one- and two-family dwellings and townhouses up to three stories.

The 2018 IBC contains many important changes such as:

  • Accessory storage spaces of any size are now permitted to be classified as part of the occupancy to which they are accessory.
  • New code sections have been introduced addressing medical gas systems and higher education laboratories.
  • Use of fire walls to create separate buildings is now limited to only the determination of permissible types of construction based on allowable building area and height.
  • Where an elevator hoistway door opens into a fire-resistance-rated corridor, the opening must be protected in a manner to address smoke intrusion into the hoistway.
  • The occupant load factor for business uses has been revised to one occupant per 150 square feet.
  • Live loads on decks and balconies increase the deck live load to one and one-half times the live load of the area served.
  • The minimum lateral load that fire walls are required to resist is five pounds per square foot.
  • Wind speed maps updated, including maps for the state of Hawaii. Terminology describing wind speeds has changed again with ultimate design wind speeds now called basic design wind speeds.
  • Site soil coefficients now correspond to the newest generation of ground motion attenuation equations (seismic values).
  • Five-foot tall wood trusses requiring permanent bracing must have a periodic special inspection to verify that the required bracing has been installed.
  • New alternative fastener schedule for construction of mechanically laminated decking is added giving equivalent power-driven fasteners for the 20-penny nail.
  • Solid sawn lumber header and girder spans for the exterior bearing walls reduce span lengths to allow #2 Southern Pine design values.

PDF Catalog

PDF Pages PDF Title
1 2018 IBC® INTERNATIONAL BUILDING CODE®
2 2018 IBC® TITLE PAGE
3 COPYRIGHT
4 PREFACE
10 EFFECTIVE USE OF THE INTERNATIONAL BUILDING CODE
20 TABLE OF CONTENTS
28 CHAPTER 1 SCOPE AND ADMINISTRATION
PART 1—SCOPE AND APPLICATION
SECTION 101 GENERAL
29 SECTION 102 APPLICABILITY
PART 2—ADMINISTRATION AND ENFORCEMENT
SECTION 103 DEPARTMENT OF BUILDING SAFETY
SECTION 104 DUTIES AND POWERS OF BUILDING OFFICIAL
31 SECTION 105 PERMITS
33 SECTION 106 FLOOR AND ROOF DESIGN LOADS
SECTION 107 SUBMITTAL DOCUMENTS
34 SECTION 108 TEMPORARY STRUCTURES AND USES
SECTION 109 FEES
35 SECTION 110 INSPECTIONS
36 SECTION 111 CERTIFICATE OF OCCUPANCY
SECTION 112 SERVICE UTILITIES
37 SECTION 113 BOARD OF APPEALS
SECTION 114 VIOLATIONS
SECTION 115 STOP WORK ORDER
SECTION 116 UNSAFE STRUCTURES AND EQUIPMENT
40 CHAPTER 2 DEFINITIONS
SECTION 201 GENERAL
SECTION 202 DEFINITIONS
72 CHAPTER 3 OCCUPANCY CLASSIFICATION AND USE
SECTION 301 SCOPE
SECTION 302 OCCUPANCY CLASSIFICATION AND USE DESIGNATION
SECTION 303 ASSEMBLY GROUP A
73 SECTION 304 BUSINESS GROUP B
SECTION 305 EDUCATIONAL GROUP E
74 SECTION 306 FACTORY GROUP F
SECTION 307 HIGH-HAZARD GROUP H
75 TABLE 307.1(1) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
76 TABLE 307.1(1)—continued MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A PHYSICAL HAZARDa, j, m, n, p
77 [F] TABLE 307.1(2) MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA OF HAZARDOUS MATERIALS POSING A HEALTH HAZARDa, c, f, h, i
78 SECTION 308 INSTITUTIONAL GROUP I
79 SECTION 309 MERCANTILE GROUP M
80 SECTION 310 RESIDENTIAL GROUP R
SECTION 311 STORAGE GROUP S
81 SECTION 312 UTILITY AND MISCELLANEOUS GROUP U
82 CHAPTER 4 SPECIAL DETAILED REQUIREMENTS BASED ON OCCUPANCY AND USE
SECTION 401 SCOPE
SECTION 402 COVERED MALL AND OPEN MALL BUILDINGS
85 EQUATION 4-1
86 SECTION 403 HIGH-RISE BUILDINGS
87 TABLE 403.2.4 MINIMUM BOND STRENGTH
89 SECTION 404 ATRIUMS
90 SECTION 405 UNDERGROUND BUILDINGS
91 SECTION 406 MOTOR-VEHICLE-RELATED OCCUPANCIES
93 TABLE 406.5.4 OPEN PARKING GARAGES AREA AND HEIGHT
95 SECTION 407 GROUP I-2
98 SECTION 408 GROUP I-3
100 SECTION 409 MOTION PICTURE PROJECTION ROOMS
101 SECTION 410 STAGES, PLATFORMS AND TECHNICAL PRODUCTION AREAS
103 SECTION 411 SPECIAL AMUSEMENT BUILDINGS
SECTION 412 AIRCRAFT-RELATED OCCUPANCIES
104 TABLE 412.2.1.1 HEIGHT LIMITATIONS FOR AIRPORT TRAFFIC CONTROL TOWERS
105 [F] TABLE 412.3.6 HANGAR FIRE SUPPRESSION REQUIREMENTSa, b, c
107 TABLE 412.6 AIRCRAFT MANUFACTURING EXIT ACCESS TRAVEL DISTANCE
SECTION 413 COMBUSTIBLE STORAGE
SECTION 414 HAZARDOUS MATERIALS
108 [F] TABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREAS
109 [F] TABLE 414.2.5(1) MAXIMUM ALLOWABLE QUANTITY PER INDOOR AND OUTDOOR CONTROL AREA IN GROUP M AND S OCCUPANCIES NONFLAMMABLE SOLIDS AND NONFLAMMABLE AND NONCOMBUSTIBLE LIQUIDSd, e, f
110 [F] TABLE 414.2.5(2) MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE AND COMBUSTIBLE LIQUIDS IN WHOLESALE AND RETAIL SALES OCCUPANCIES PER CONTROL AREAa
SECTION 415 GROUPS H-1, H-2, H-3, H-4 AND H-5
111 [F] TABLE 414.5.1 EXPLOSION CONTROL REQUIREMENTSa, h
113 [F] TABLE 415.6.2 DETACHED BUILDING REQUIRED
115 [F] TABLE 415.11.1.1.1 QUANTITY LIMITS FOR HAZARDOUS MATERIALS IN A SINGLE FABRICATION AREA IN GROUP H-5a
120 SECTION 416 SPRAY APPLICATION OF FLAMMABLE FINISHES
121 SECTION 417 DRYING ROOMS
SECTION 418 ORGANIC COATINGS
SECTION 419 LIVE/WORK UNITS
122 SECTION 420 GROUPS I-1, R-1, R-2, R-3 AND R-4
123 SECTION 421 HYDROGEN FUEL GAS ROOMS
124 SECTION 422 AMBULATORY CARE FACIILITIES
SECTION 423 STORM SHELTERS
125 SECTION 424 CHILDREN’S PLAY STRUCTURES
SECTION 425 HYPERBARIC FACILITIES
SECTION [F] 426 COMBUSTIBLE DUSTS, GRAIN PROCESSING AND STORAGE
126 SECTION 427 MEDICAL GAS SYSTEMS
127 SECTION 428 HIGHER EDUCATION LABORATORIES
[F] TABLE 428.3 DESIGN AND NUMBER OF LABORATORY SUITES PER FLOOR
130 CHAPTER 5 GENERAL BUILDING HEIGHTS AND AREAS
SECTION 501 GENERAL
SECTION 502 BUILDING ADDRESS
SECTION 503 GENERAL BUILDING HEIGHT AND AREA LIMITATIONS
131 SECTION 504 BUILDING HEIGHT AND NUMBER OF STORIES
TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANEa
132 SECTION 505 MEZZANINES AND EQUIPMENT PLATFORMS
133 TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b
134 TABLE 504.4—continued ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANEa, b
SECTION 506 BUILDING AREA
135 EQUATION 5-1
EQUATION 5-2
EQUATION 5-3
136 TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
137 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
138 TABLE 506.2—continued ALLOWABLE AREA FACTOR (At = NS, S1, S13R, S13D or SM, as applicable) IN SQUARE FEETa, b
EQUATION 5-4
EQUATION 5-5
SECTION 507 UNLIMITED AREA BUILDINGS
140 SECTION 508 MIXED USE AND OCCUPANCY
142 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS)f
SECTION 509 INCIDENTAL USES
SECTION 510 SPECIAL PROVISIONS
143 [F] TABLE 509 INCIDENTAL USES
146 CHAPTER 6 TYPES OF CONSTRUCTION
SECTION 601 GENERAL
TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
SECTION 602 CONSTRUCTION CLASSIFICATION
147 TABLE 602 FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCEa, d, g
SECTION 603 COMBUSTIBLE MATERIAL IN TYPES I AND II CONSTRUCTION
150 CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES
SECTION 701 GENERAL
SECTION 702 MULTIPLE USE FIRE ASSEMBLIES
SECTION 703 FIRE-RESISTANCE RATINGS AND FIRE TESTS
151 SECTION 704 FIRE-RESISTANCE RATING OF STRUCTURAL MEMBERS
153 SECTION 705 EXTERIOR WALLS
TABLE 705.2 MINIMUM DISTANCE OF PROJECTION
154 EQUATION 7-1
EQUATION 7-2
155 FIGURE 705.7 EQUIVALENT OPENING FACTOR
156 TABLE 705.8 MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION DISTANCE AND DEGREE OF OPENING PROTECTION
157 SECTION 706 FIRE WALLS
158 TABLE 706.4 FIRE WALL FIRE-RESISTANCE RATINGS
159 SECTION 707 FIRE BARRIERS
160 TABLE 707.3.10 FIRE-RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIERS, FIRE WALLS OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS
161 SECTION 708 FIRE PARTITIONS
162 SECTION 709 SMOKE BARRIERS
163 SECTION 710 SMOKE PARTITIONS
SECTION 711 FLOOR AND ROOF ASSEMBLIES
164 SECTION 712 VERTICAL OPENINGS
166 SECTION 713 SHAFT ENCLOSURES
167 SECTION 714 PENETRATIONS
170 SECTION 715 FIRE-RESISTANT JOINT SYSTEMS
171 SECTION 716 OPENING PROTECTIVES
172 TABLE 716.1(1) MARKING FIRE-RATED GLAZING ASSEMBLIES
173 TABLE 716.1(2) OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
174 TABLE 716.1(2)—continued OPENING FIRE PROTECTION ASSEMBLIES, RATINGS AND MARKINGS
177 TABLE 716.1(3) FIRE WINDOW ASSEMBLY FIRE PROTECTION RATINGS
SECTION 717 DUCTS AND AIR TRANSFER OPENINGS
178 TABLE 717.3.2.1 FIRE DAMPER RATING
182 SECTION 718 CONCEALED SPACES
184 SECTION 719 FIRE-RESISTANCE REQUIREMENTS FOR PLASTER
SECTION 720 THERMAL- AND SOUND-INSULATING MATERIALS
185 SECTION 721 PRESCRIPTIVE FIRE RESISTANCE
SECTION 722 CALCULATED FIRE RESISTANCE
186 TABLE 721.1(1) MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
187 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
188 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
189 TABLE 721.1(1)—continued MINIMUM PROTECTION OF STRUCTURAL PARTS BASED ON TIME PERIODS FOR VARIOUS NONCOMBUSTIBLE INSULATING MATERIALSm
190 TABLE 721.1(2) RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
191 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
192 TABLE 721.1(2) —continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
193 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
194 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
195 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
196 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
197 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o, p
198 TABLE 721.1(2)—continued RATED FIRE-RESISTANCE PERIODS FOR VARIOUS WALLS AND PARTITIONS a, o,
TABLE 721.1(3) MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
199 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
200 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
201 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
202 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
203 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
204 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
205 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
206 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
207 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
208 TABLE 721.1(3)—continued MINIMUM PROTECTION FOR FLOOR AND ROOF SYSTEMSa, q
209 TABLE 722.2.1.1 MINIMUM EQUIVALENT THICKNESS OF CAST-IN-PLACE OR PRECAST CONCRETE WALLS, LOAD-BEARING OR NONLOAD-BEARING
EQUATION 7-3
EQUATION 7-4
FIGURE 722.2.1.3.1 CERAMIC FIBER JOINT PROTECTION
210 FIGURE 722.2.1.2 FIRE-RESISTANCE RATINGS OF TWO-WYTHE CONCRETE WALLS
TABLE 722.2.1.2(1) VALUES OF Rn0.59 FOR USE IN EQUATION 7-4
TABLE 722.2.1.2(2) FIRE-RESISTANCE RATINGS BASED ON R0.59
211 TABLE 722.2.1.4(1) MULTIPLYING FACTOR FOR FINISHES ON NONFIRE-EXPOSED SIDE OF WALL
TABLE 722.2.1.4(2) TIME ASSIGNED TO FINISH MATERIALS ON FIRE-EXPOSED SIDE OF WALL
212 TABLE 722.2.2.1 MINIMUM SLAB THICKNESS (inches)
FIGURE 722.2.2.1.2 DETERMINATION OF SLAB THICKNESS FOR SLOPING SOFFITS
EQUATION 7-5
FIGURE 722.2.2.1.3 SLABS WITH RIBBED OR UNDULATING SOFFITS
FIGURE 722.2.2.2 FIRE-RESISTANCE RATINGS FOR TWO-COURSE CONCRETE FLOORS
213 FIGURE 722.2.2.3(1) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
FIGURE 722.2.2.3(2) FIRE-RESISTANCE RATINGS FOR CONCRETE ROOF ASSEMBLIES
214 TABLE 722.2.3(1) COVER THICKNESS FOR REINFORCED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(2) COVER THICKNESS FOR PRESTRESSED CONCRETE FLOOR OR ROOF SLABS (inches)
TABLE 722.2.3(3) MINIMUM COVER FOR MAIN REINFORCING BARS OF REINFORCED CONCRETE BEAMSc (APPLICABLE TO ALL TYPES OF STRUCTURAL CONCRETE)
215 TABLE 722.2.3(4) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS 8 INCHES OR GREATER IN WIDTHb
TABLE 722.2.3(5) MINIMUM COVER FOR PRESTRESSED CONCRETE BEAMS OF ALL WIDTHS
216 TABLE 722.2.4 MINIMUM DIMENSION OF CONCRETE COLUMNS (inches)
TABLE 722.3.2 MINIMUM EQUIVALENT THICKNESS (inches) OF BEARING OR NONBEARING CONCRETE MASONRY WALLSa, b, c, d
217 EQUATION 7-6
EQUATION 7-7
TABLE 722.3.4 MINIMUM COVER OF LONGITUDINAL REINFORCEMENT IN FIRE-RESISTANCE-RATED REINFORCED CONCRETE MASONRY LINTELS (inches)
218 TABLE 722.3.5 MINIMUM DIMENSION OF CONCRETE MASONRY COLUMNS (inches)
EQUATION 7-8
TABLE 722.4.1(1) FIRE-RESISTANCE PERIODS OF CLAY MASONRY WALLS
TABLE 722.4.1(2) FIRE-RESISTANCE RATINGS FOR BEARING STEEL FRAME BRICK VENEER WALLS OR PARTITIONS
219 EQUATION 7-9
TABLE 722.4.1(3) VALUES OF Rn 0.59
TABLE 722.4.1(4) COEFFICIENTS FOR PLASTER, pl a
TABLE 722.4.1(5) REINFORCED MASONRY LINTELS
TABLE 722.4.1(6) REINFORCED CLAY MASONRY COLUMNS
EQUATION 7-10
EQUATION 7-11
220 FIGURE 722.5.1(1) DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL COLUMNS
EQUATION 7-12
FIGURE 722.5.1(2) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH SHEET STEEL COLUMN COVERS
221 FIGURE 722.5.1(3) GYPSUM-PROTECTED STRUCTURAL STEEL COLUMNS WITH STEEL STUD/SCREW ATTACHMENT SYSTEM
FIGURE 722.5.1(4) FIRE RESISTANCE OF STRUCTURAL STEEL COLUMNS PROTECTED WITH VARIOUS THICKNESSES OF TYPE X GYPSUM WALLBOARD
FIGURE 722.5.1(5) WIDE FLANGE STRUCTURAL STEEL COLUMNS WITH SPRAYED FIRE-RESISTANT MATERIALS
222 FIGURE 722.5.1(6) CONCRETE PROTECTED STRUCTURAL STEEL COLUMNSa, b
FIGURE 722.5.1(7) CONCRETE OR CLAY MASONRY PROTECTED STRUCTURAL STEEL COLUMNS
EQUATION 7-13
223 EQUATION 7-14
EQUATION 7-15
EQUATOIN 7-16
224 FIGURE 722.5.2 DETERMINATION OF THE HEATED PERIMETER OF STRUCTURAL STEEL BEAMS AND GIRDERS
EQUATION 7-17
226 TABLE 722.5.1(1) W/D RATIOS FOR STEEL COLUMNS
TABLE 722.5.1(2) PROPERTIES OF CONCRETE
227 TABLE 722.5.1(3) THERMAL CONDUCTIVITY OF CONCRETE OR CLAY MASONRY UNITS
TABLE 722.5.1(4) WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
228 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
229 TABLE 722.5.1(4)—continued WEIGHT-TO-HEATED-PERIMETER RATIOS (W/D) FOR TYPICAL WIDE FLANGE BEAM AND GIRDER SHAPES
230 TABLE 722.5.1(5) FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
231 TABLE 722.5.1(5)—continued FIRE RESISTANCE OF CONCRETE MASONRY PROTECTED STEEL COLUMNS
232 TABLE 722.5.1(6) FIRE RESISTANCE OF CLAY MASONRY PROTECTED STEEL COLUMNS
233 TABLE 722.5.1(7) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN NORMAL-WEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
TABLE 722.5.1(8) MINIMUM COVER (inch) FOR STEEL COLUMNS ENCASED IN STRUCTURAL LIGHTWEIGHT CONCRETEa [FIGURE 722.5.1(6)(c)]
234 TABLE 722.5.1(9) MINIMUM COVER (inch) FOR STEEL COLUMNS IN NORMAL-WEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
TABLE 722.5.1(10) MINIMUM COVER (inch) FOR STEEL COLUMNS IN STRUCTURAL LIGHTWEIGHT PRECAST COVERSa [FIGURE 722.5.1(6)(a)]
235 TABLE 722.6.2(1) TIME ASSIGNED TO WALLBOARD MEMBRANESa, b, c, d
TABLE 722.6.2(2) TIME ASSIGNED FOR CONTRIBUTION OF WOOD FRAME a, b, c
TABLE 722.6.2(3) MEMBRANEa ON EXTERIOR FACE OF WOOD STUD WALLS
236 TABLE 722.6.2(4) FLOORING OR ROOFING OVER WOOD FRAMINGa
TABLE 722.6.2(5) TIME ASSIGNED FOR ADDITIONAL PROTECTION
238 CHAPTER 8 INTERIOR FINISHES
SECTION 801 SCOPE
SECTION 802 GENERAL
SECTION 803 WALL AND CEILING FINISHES
240 TABLE 803.13 INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCYk
241 SECTION 804 INTERIOR FLOOR FINISH
242 SECTION 805 COMBUSTIBLE MATERIALS IN TYPES I AND II CONSTRUCTION
SECTION 806 DECORATIVE MATERIALS AND TRIM
243 SECTION 807 INSULATION
SECTION 808 ACOUSTICAL CEILING SYSTEMS
244 CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS
SECTION 901 GENERAL
245 SECTION 902 FIRE PUMP AND RISER ROOM SIZE
SECTION 903 AUTOMATIC SPRINKLER SYSTEMS
246 [F] TABLE 903.2.5.2 GROUP H-5 SPRINKLER DESIGN CRITERIA
249 [F] TABLE 903.2.11.6 ADDITIONAL REQUIRED SUPPRESSION SYSTEMS
251 SECTION 904 ALTERNATIVE AUTOMATIC FIRE-EXTINGUISHING SYSTEMS
254 SECTION 905 STANDPIPE SYSTEMS
256 SECTION 906 PORTABLE FIRE EXTINGUISHERS
257 [F] TABLE 906.1 ADDITIONAL REQUIRED PORTABLE FIRE EXTINGUISHERS IN THE INTERNATIONAL FIRE CODE
[F] TABLE 906.3(1) FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS
[F] TABLE 906.3(2) FIRE EXTINGUISHERS FOR FLAMMABLE OR COMBUSTIBLE LIQUIDS WITH DEPTHS LESS THAN OR EQUAL TO 0.25 INCHa
258 SECTION 907 FIRE ALARM AND DETECTION SYSTEMS
267 [F] TABLE 907.5.2.3.2 VISIBLE ALARMS
268 SECTION 908 EMERGENCY ALARM SYSTEMS
SECTION 909 SMOKE CONTROL SYSTEMS
270 EQUATION 9-1
271 EQUATION 9-2
277 SECTION 910 SMOKE AND HEAT REMOVAL
EQUATION 9-3
EQUATION 9-4
278 SECTION 911 FIRE COMMAND CENTER
279 SECTION 912 FIRE DEPARTMENT CONNECTIONS
SECTION 913 FIRE PUMPS
280 SECTION 914 EMERGENCY RESPONDER SAFETY FEATURES
SECTION 915 CARBON MONOXIDE DETECTION
282 SECTION 916 GAS DETECTION SYSTEMS
SECTION 917 MASS NOTIFICATION SYSTEMS
SECTION 918 EMERGENCY RESPONDER RADIO COVERAGE
284 CHAPTER 10 MEANS OF EGRESS
SECTION 1001 ADMINISTRATION
[F] SECTION 1002 MAINTENANCE AND PLANS
SECTION 1003 GENERAL MEANS OF EGRESS
285 SECTION 1004 OCCUPANT LOAD
286 TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT
287 SECTION 1005 MEANS OF EGRESS SIZING
288 SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
289 TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY
290 TABLE 1006.3.2 MINIMUM NUMBER OF EXITS OR ACCESS TO EXITS PER STORY
TABLE 1006.3.3(1) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR R-2 OCCUPANCIES
TABLE 1006.3.3(2) STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
291 SECTION 1007 EXIT AND EXIT ACCESS DOORWAY CONFIGURATION
SECTION 1008 MEANS OF EGRESS ILLUMINATION
292 SECTION 1009 ACCESSIBLE MEANS OF EGRESS
295 SECTION 1010 DOORS, GATES AND TURNSTILES
296 TABLE 1010.1.4.1(1) MAXIMUM DOOR SPEED MANUAL REVOLVING DOORS
297 TABLE 1010.1.4.1(2) MAXIMUM DOOR SPEED AUTOMATIC OR POWER-OPERATED REVOLVING DOORS
303 SECTION 1011 STAIRWAYS
307 SECTION 1012 RAMPS
308 SECTION 1013 EXIT SIGNS
309 SECTION 1014 HANDRAILS
310 SECTION 1015 GUARDS
311 SECTION 1016 EXIT ACCESS
312 SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2 EXIT ACCESS TRAVEL DISTANCEa
313 SECTION 1018 AISLES
SECTION 1019 EXIT ACCESS STAIRWAYS AND RAMPS
314 SECTION 1020 CORRIDORS
TABLE 1020.1 CORRIDOR FIRE-RESISTANCE RATING
TABLE 1020.2 MINIMUM CORRIDOR WIDTH
315 SECTION 1021 EGRESS BALCONIES
SECTION 1022 EXITS
316 SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
318 SECTION 1024 EXIT PASSAGEWAYS
SECTION 1025 LUMINOUS EGRESS PATH MARKINGS
320 SECTION 1026 HORIZONTAL EXITS
SECTION 1027 EXTERIOR EXIT STAIRWAYS AND RAMPS
321 SECTION 1028 EXIT DISCHARGE
322 SECTION 1029 ASSEMBLY
323 TABLE 1029.6.2 CAPACITY FOR AISLES FOR SMOKE-PROTECTED ASSEMBLY
327 TABLE 1029.13.2.1 SMOKE-PROTECTED OR OPEN-AIR ASSEMBLY AISLE ACCESSWAYS
329 SECTION 1030 EMERGENCY ESCAPE AND RESCUE
332 CHAPTER 11 ACCESSIBILITY
SECTION 1101 GENERAL
SECTION 1102 COMPLIANCE
SECTION 1103 SCOPING REQUIREMENTS
333 SECTION 1104 ACCESSIBLE ROUTE
334 SECTION 1105 ACCESSIBLE ENTRANCES
SECTION 1106 PARKING AND PASSENGER LOADING FACILITIES
335 TABLE 1106.1 ACCESSIBLE PARKING SPACES
SECTION 1107 DWELLING UNITS AND SLEEPING UNITS
337 TABLE 1107.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
339 SECTION 1108 SPECIAL OCCUPANCIES
TABLE 1108.2.2.1 ACCESSIBLE WHEELCHAIR SPACES
340 TABLE 1108.2.7.1 RECEIVERS FOR ASSISTIVE LISTENING SYSTEMS
341 TABLE 1108.3 ACCESSIBLE SELF-SERVICE STORAGE FACILITIES
SECTION 1109 OTHER FEATURES AND FACILITIES
344 TABLE 1109.12.2 ACCESSIBLE CHECK-OUT AISLES
SECTION 1110 RECREATIONAL FACILITIES
345 TABLE 1110.4.9.1 BOAT SLIPS
346 SECTION 1111 SIGNAGE
348 CHAPTER 12 INTERIOR ENVIRONMENT
SECTION 1201 GENERAL
SECTION 1202 VENTILATION
349 TABLE 1202.3 INSULATION FOR CONDENSATION CONTROL
350 SECTION 1203 TEMPERATURE CONTROL
SECTION 1204 LIGHTING
351 SECTION 1205 YARDS OR COURTS
SECTION 1206 SOUND TRANSMISSION
352 SECTION 1207 INTERIOR SPACE DIMENSIONS
SECTION 1208 ACCESS TO UNOCCUPIED SPACES
SECTION 1209 TOILET AND BATHROOM REQUIREMENTS
354 CHAPTER 13 ENERGY EFFICIENCY
SECTION 1301 GENERAL
356 CHAPTER 14 EXTERIOR WALLS
SECTION 1401 GENERAL
SECTION 1402 PERFORMANCE REQUIREMENTS
357 SECTION 1403 MATERIALS
SECTION 1404 INSTALLATION OF WALL COVERINGS
358 TABLE 1404.2 MINIMUM THICKNESS OF WEATHER COVERINGS
TABLE 1404.3.2 CLASS III VAPOR RETARDERS
363 SECTION 1405 COMBUSTIBLE MATERIALS ON THE EXTERIOR SIDE OF EXTERIOR WALLS
TABLE 1405.1.1.1.2 MINIMUM FIRE SEPARATION FOR COMBUSTIBLE EXTERIOR WALL COVERINGS
364 SECTION 1406 METAL COMPOSITE MATERIALS (MCM)
365 TABLE 1406.11.3.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR MCM PANELS
366 SECTION 1407 EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS)
SECTION 1408 HIGH-PRESSURE DECORATIVE EXTERIOR-GRADE COMPACT LAMINATES (HPL)
367 SECTION 1409 PLASTIC COMPOSITE DECKING
368 CHAPTER 15 ROOF ASSEMBLIES AND ROOFTOP STRUCTURES
SECTION 1501 GENERAL
SECTION 1502 ROOF DRAINAGE
SECTION 1503 WEATHER PROTECTION
369 SECTION 1504 PERFORMANCE REQUIREMENTS
TABLE 1504.1.1 CLASSIFICATION OF STEEP SLOPE ROOF SHINGLES TESTED IN ACCORDANCE WITH ASTM D316 OR D71581
370 TABLE 1504.8 MAXIMUM ALLOWABLE MEAN ROOF HEIGHT PERMITTED FOR BUILDINGS WITH AGGREGATE ON THE ROOF IN AREAS OUTSIDE A HURRICANE-PRONE REGION
SECTION 1505 FIRE CLASSIFICATION
TABLE 1505.1a, b MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION
371 SECTION 1506 MATERIALS
SECTION 1507 REQUIREMENTS FOR ROOF COVERINGS
372 TABLE 1507.1.1(1) UNDERLAYMENT TYPES
373 TABLE 1507.1.1(2) UNDERLAYMENT APPLICATION
374 TABLE 1507.1.1(3) UNDERLAYMENT ATTACHMENT
375 TABLE 1507.2.8.2 VALLEY LINING MATERIAL
376 TABLE 1507.3.7 CLAY AND CONCRETE TILE ATTACHMENTa, b, c
377 TABLE 1507.4.3(1) METAL ROOF COVERINGS
TABLE 1507.4.3(2) MINIMUM CORROSION RESISTANCE
378 TABLE 1507.7.6 SLATE SHINGLE HEADLAP
TABLE 1507.8.5 WOOD SHINGLE MATERIAL REQUIREMENTS
TABLE 1507.8.7 WOOD SHINGLE WEATHER EXPOSURE AND ROOF SLOPE
379 TABLE 1507.8 WOOD SHINGLE AND SHAKE INSTALLATION
380 TABLE 1507.9.6 WOOD SHAKE MATERIAL REQUIREMENTS
TABLE 1507.9.8 WOOD SHAKE WEATHER EXPOSURE AND ROOF SLOPE
381 TABLE 1507.10.2 BUILT-UP ROOFING MATERIAL STANDARDS
TABLE 1507.14.3 PROTECTIVE COATING MATERIAL STANDARDS
383 SECTION 1508 ROOF INSULATION
[BF] TABLE 1508.2 MATERIAL STANDARDS FOR ROOF INSULATION
SECTION 1509 RADIANT BARRIERS INSTALLED ABOVE DECK
SECTION 1510 ROOFTOP STRUCTURES
385 SECTION 1511 REROOFING
386 SECTION 1512 PHOTOVOLTAIC PANELS AND MODULES
388 CHAPTER 16 STRUCTURAL DESIGN
SECTION 1601 GENERAL
SECTION 1602 NOTATIONS
SECTION 1603 CONSTRUCTION DOCUMENTS
389 SECTION 1604 GENERAL DESIGN REQUIREMENTS
390 TABLE 1604.3 DEFLECTION LIMITSa, b, c, h, i
391 TABLE 1604.5 RISK CATEGORY OF BUILDINGS AND OTHER STRUCTURES
392 SECTION 1605 LOAD COMBINATIONS
393 EQUATION 16-1
EQUATION 16-2
EQUATION 16-3
EQUATION 16-4
EQUATION 16-5
EQUATION 16-6
EQUATION 16-7
EQUATION 16-8
EQUATION 16-9
EQUATION 16-10
EQUATION 16-11
EQUATION 16-12
EQUATION 16-13
EQUATION 16-14
EQUATION 16-15
EQUATION 16-16
394 EQUATION 16-17
EQUATION 16-18
EQUATION 16-19
EQUATION 16-20
EQUATION 16-21
EQUATION 16-22
SECTION 1606 DEAD LOADS
SECTION 1607 LIVE LOADS
395 TABLE 1607.1 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
396 TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, L0, AND MINIMUM CONCENTRATED LIVE LOADSg
TABLE 1607.1—continued MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS, Lo, AND MINIMUM CONCENTRATED LIVE LOADSg
398 EQUATION 16-23
TABLE 1607.11.1 LIVE LOAD ELEMENT FACTOR, KLL
EQUATION 16-24
399 EQUATION 16-25
EQUATION 16-26
EQUATION 16-27
EQUATION 16-28
EQUATION 16-29
EQUATION 16-30
EQUATION 16-31
EQUATION 16-32
401 SECTION 1608 SNOW LOADS
TABLE 1608.2 GROUND SNOW LOADS, pg, FOR ALASKAN LOCATIONS
SECTION 1609 WIND LOADS
402 TABLE 1609.2 WINDBORNE DEBRIS PROTECTION FASTENING SCHEDULE FOR WOOD STRUCTURAL PANELSa, b, c, d
403 FIGURE 1608.2 GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
404 FIGURE 1608.2—continued GROUND SNOW LOADS, pg, FOR THE UNITED STATES (psf)
405 EQUATION 16-33
TABLE 1609.3.1 WIND SPEED CONVERSIONSa, b, c
406 FIGURE 1609.3(1) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES
407 FIGURE 1609.3(2) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES
408 FIGURE 1609.3(3) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES
409 FIGURE 1609.3(4) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES
410 FIGURE 1609.3(5) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
411 FIGURE 1609.3(5)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY II BUILDINGS AND OTHER STRUCTURES IN HAWAII
412 FIGURE 1609.3(6) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
413 FIGURE 1609.3(6)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY III BUILDINGS AND OTHER STRUCTURES IN HAWAII
414 FIGURE 1609.3(7) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
415 FIGURE 1609.3(7)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY IV BUILDINGS AND OTHER STRUCTURES IN HAWAII
416 FIGURE 1609.3(8) BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
417 FIGURE 1609.3(8)—continued BASIC DESIGN WIND SPEEDS, V, FOR RISK CATEGORY I BUILDINGS AND OTHER STRUCTURES IN HAWAII
418 EQUATION 16-34
SECTION 1610 SOIL LATERAL LOADS
SECTION 1611 RAIN LOADS
EQUATION 16-35
419 TABLE 1610.1 LATERAL SOIL LOAD
SECTION 1612 FLOOD LOADS
420 [P] FIGURE 1611.1 100-YEAR, 1-HOUR RAINFALL (INCHES) WESTERN UNITED STATES
421 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) CENTRAL UNITED STATES
422 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) EASTERN UNITED STATES
423 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) ALASKA
424 [P] FIGURE 1611.1—continued 100-YEAR, 1-HOUR RAINFALL (INCHES) HA
425 SECTION 1613 EARTHQUAKE LOADS
426 EQUATON 16-36
EQUATOIN 16-37
EQUATION 16-38
EQUATION 16-39
TABLE 1613.2.3(1) VALUES OF SITE COEFFICIENT Fa a
427 TABLE 1613.2.3(2) VALUES OF SITE COEFFICIENT FV a
TABLE 1613.2.5(1) SEISMIC DESIGN CATEGORY BASED ON SHORT-PERIOD (0.2 second) RESPONSE ACCELERATION
TABLE 1613.2.5(2) SEISMIC DESIGN CATEGORY BASED ON 1-SECOND PERIOD RESPONSE ACCELERATION
428 SECTION 1614 ATMOSPHERIC ICE LOADS
SECTION 1615 TSUNAMI LOADS
SECTION 1616 STRUCTURAL INTEGRITY
429 EQUATION 16-40
EQUATION 16-41
431 FIGURE 1613.2.1(1) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
432 FIGURE 1613.2.1(1)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
433 FIGURE 1613.2.1(2) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
434 FIGURE 1613.2.1(2)—continued RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR THE CONTERMINOUS UNITED STATES OF 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
435 FIGURE 1613.2.1(3) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR HAWAII OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
436 FIGURE 1613.2.1(4) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 0.2-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
437 FIGURE 1613.2.1(5) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR ALASKA OF 1.0-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
438 FIGURE 1613.2.1(6) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR PUERTO RICO AND THE UNITED STATES VIRGIN ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
439 FIGURE 1613.2.1(7) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR GUAM AND THE NORTHERN MARIANA ISLANDS OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
440 FIGURE 1613.2.1(8) RISK-TARGETED MAXIMUM CONSIDERED EARTHQUAKE (MCER) GROUND MOTION RESPONSE ACCELERATIONS FOR AMERICAN SAMOA OF 0.2- AND 1-SECOND SPECTRAL RESPONSE ACCELERATION (5% OF CRITICAL DAMPING)
441 FIGURE 1616.3 LONGITUDINAL, PERIMETER, TRANSVERSE AND VERTICAL TIES
442 CHAPTER 17 SPECIAL INSPECTIONS AND TESTS
SECTION 1701 GENERAL
SECTION 1702 NEW MATERIALS
SECTION 1703 APPROVALS
443 SECTION 1704 SPECIAL INSPECTIONS AND TESTS, CONTRACTOR RESPONSIBILITY AND STRUCTURAL OBSERVATION
445 SECTION 1705 REQUIRED SPECIAL INSPECTIONS AND TESTS
446 TABLE 1705.2.3 REQUIRED SPECIAL INSPECTIONS OF OPEN-WEB STEEL JOISTS AND JOIST GIRDERS
447 TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
448 TABLE 1705.6 REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS
TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS
TABLE 1705.8 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CAST-IN-PLACE DEEP FOUNDATION ELEMENTS
453 SECTION 1706 DESIGN STRENGTHS OF MATERIALS
SECTION 1707 ALTERNATIVE TEST PROCEDURE
SECTION 1708 IN-SITU LOAD TESTS
454 SECTION 1709 PRECONSTRUCTION LOAD TESTS
456 CHAPTER 18 SOILS AND FOUNDATIONS
SECTION 1801 GENERAL
SECTION 1802 DESIGN BASIS
SECTION 1803 GEOTECHNICAL INVESTIGATIONS
458 SECTION 1804 EXCAVATION, GRADING AND FILL
459 SECTION 1805 DAMPPROOFING AND WATERPROOFING
460 SECTION 1806 PRESUMPTIVE LOAD-BEARING VALUES OF SOILS
461 TABLE 1806.2 PRESUMPTIVE LOAD-BEARING VALUES
SECTION 1807 FOUNDATION WALLS, RETAINING WALLS AND EMBEDDED POSTS AND POLES
463 TABLE 1807.1.6.2 CONCRETE FOUNDATION WALLSb, c
464 TABLE 1807.1.6.3(1) PLAIN MASONRY FOUNDATION WALLSa, b, c
EQUATION 18-1
465 TABLE 1807.1.6.3(2) 8-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 5 INCHESa, b, c
EQUATION 18-2
EQUATION 18-3
466 TABLE 1807.1.6.3(3) 10-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 6.75 INCHES a, b, c
SECTION 1808 FOUNDATIONS
467 TABLE 1807.1.6.3(4) 12-INCH MASONRY FOUNDATION WALLS WITH REINFORCEMENT WHERE d ≥ 8.75 INCHESa, b, c
468 FIGURE 1808.7.1 FOUNDATION CLEARANCES FROM SLOPES
469 TABLE 1808.8.1 MINIMUM SPECIFIED COMPRESSIVE STRENGTH f ´ C OF CONCRETE OR GROUT
TABLE 1808.8.2 MINIMUM CONCRETE COVER
470 SECTION 1809 SHALLOW FOUNDATIONS
TABLE 1809.7 PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME CONSTRUCTIONa, b, c, d, e
471 SECTION 1810 DEEP FOUNDATIONS
474 TABLE 1810.3.2.6 ALLOWABLE STRESSES FOR MATERIALS USED IN DEEP FOUNDATION ELEMENTS
475 EQUATION 18-4
478 EQUATION 18-5
EQUATION 18-6
EQUATION 18-7
EQUATION 18-8
479 EQUATION 18-9
EQUATION 18-10
486 CHAPTER 19 CONCRETE
SECTION 1901 GENERAL
SECTION 1902 DEFINITIONS
SECTION 1903 SPECIFICATIONS FOR TESTS AND MATERIALS
487 SECTION 1904 DURABILITY REQUIREMENTS
SECTION 1905 MODIFICATIONS TO ACI 318
489 SECTION 1906 STRUCTURAL PLAIN CONCRETE
SECTION 1907 MINIMUM SLAB PROVISIONS
490 SECTION 1908 SHOTCRETE
492 CHAPTER 20 ALUMINUM
SECTION 2001 GENERAL
SECTION 2002 MATERIALS
494 CHAPTER 21 MASONRY
SECTION 2101 GENERAL
SECTION 2102 NOTATIONS
SECTION 2103 MASONRY CONSTRUCTION MATERIALS
495 TABLE 2103.2.3 CERAMIC TILE MORTAR COMPOSITIONS
SECTION 2104 CONSTRUCTION
SECTION 2105 QUALITY ASSURANCE
SECTION 2106 SEISMIC DESIGN
SECTION 2107 ALLOWABLE STRESS DESIGN
496 EQUATION 21-1
SECTION 2108 STRENGTH DESIGN OF MASONRY
SECTION 2109 EMPIRICAL DESIGN OF ADOBE MASONRY
497 EQUATION 21-2
TABLE 2109.2.3.1 ALLOWABLE SHEAR ON BOLTS IN ADOBE MASONRY
498 SECTION 2110 GLASS UNIT MASONRY
SECTION 2111 MASONRY FIREPLACES
500 FIGURE 2111.12 ILLUSTRATION OF EXCEPTION TO FIREPLACE CLEARANCE PROVISION
SECTION 2112 MASONRY HEATERS
501 SECTION 2113 MASONRY CHIMNEYS
504 FIGURE 2113.16 FLUE SIZES FOR MASONRY CHIMNEYS
TABLE 2113.16(1) NET CROSS-SECTIONAL AREA OF ROUND FLUE SIZESa
TABLE 2113.16(2) NET CROSS-SECTIONAL AREA OF SQUARE AND RECTANGULAR FLUE SIZES
505 FIGURE 2113.19 ILLUSTRATION OF EXCEPTION THREE CHIMNEY CLEARANCE PROVISION
SECTION 2114 DRY-STACK MASONRY
TABLE 2114.4 GROSS CROSS-SECTIONAL AREA ALLOWABLE STRESS FOR DRY-STACK MASONRY
506 CHAPTER 22 STEEL
SECTION 2201 GENERAL
SECTION 2202 IDENTIFICATION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2203 PROTECTION OF STEEL FOR STRUCTURAL PURPOSES
SECTION 2204 CONNECTIONS
SECTION 2205 STRUCTURAL STEEL
507 SECTION 2206 COMPOSITE STRUCTURAL STEEL AND CONCRETE STRUCTURES
SECTION 2207 STEEL JOISTS
508 SECTION 2208 STEEL CABLE STRUCTURES
SECTION 2209 STEEL STORAGE RACKS
SECTION 2210 COLD-FORMED STEEL
SECTION 2211 COLD-FORMED STEEL LIGHT-FRAME CONSTRUCTION
510 CHAPTER 23 WOOD
SECTION 2301 GENERAL
SECTION 2302 DESIGN REQUIREMENTS
SECTION 2303 MINIMUM STANDARDS AND QUALITY
514 SECTION 2304 GENERAL CONSTRUCTION REQUIREMENTS
515 TABLE 2304.6.1 MAXIMUM ALLOWABLE STRESS DESIGN WIND SPEED, Vasd PERMITTED FOR WOOD STRUCTURAL PANEL WALL SHEATHING USED TO RESIST WIND PRESSURESa, b, c
TABLE 2304.8(1) ALLOWABLE SPANS FOR LUMBER FLOOR AND ROOF SHEATHING
516 TABLE 2304.8(2) SHEATHING LUMBER, MINIMUM GRADE REQUIREMENTS: BOARD GRADE
517 TABLE 2304.8(3) ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANEL SHEATHING AND SINGLE-FLOOR GRADES CONTINUOUS OVER TWO OR MORE SPANS WITH STRENGTH AXIS PERPENDICULAR TO SUPPORTSa
TABLE 2304.8(4) ALLOWABLE SPAN FOR WOOD STRUCTURAL PANEL COMBINATION SUBFLOOR-UNDERLAYMENT (SINGLE FLOOR)a (Panels Continuous Over Two or More Spans and Strength Axis Perpendicular to Supports)
518 TABLE 2304.8(5) ALLOWABLE LOAD (PSF) FOR WOOD STRUCTURAL PANEL ROOF SHEATHING CONTINUOUS OVER TWO OR MORE SPANS AND STRENGTH AXIS PARALLEL TO SUPPORTS (Plywood structural panels are five-ply, five-layer unless otherwise noted)a
TABLE 2304.9.3.2 FASTENING SCHEDULE FOR MECHANICALLY LAMINATED DECKING USING LAMINATIONS OF 2-INCH NOMINAL THICKNESS
520 TABLE 2304.10.1 FASTENING SCHEDULE
521 TABLE 2304.10.1—continued FASTENING SCHEDULE
522 TABLE 2304.10.1—continued FASTENING SCHEDULE
523 TABLE 2304.10.1—continued FASTENING SCHEDULE
524 TABLE 2304.10.1—continued FASTENING SCHEDULE
525 TABLE 2304.11 MINIMUM DIMENSIONS OF HEAVY TIMBER STRUCTURAL MEMBERS
527 SECTION 2305 GENERAL DESIGN REQUIREMENTS FOR LATERAL FORCE-RESISTING SYSTEMS
EQUATION 23-1
TABLE 2305.2(1)en VALUES (inches) FOR USE IN CALCULATING DIAPHRAGM AND SHEAR WALL DEFLECTION DUE TO FASTENER SLIP (Structural I)a, c
EQUATION 23-2
528 TABLE 2305.2(2)V ALUES OF Gt FOR USE IN CALCULATING DEFLECTION OF WOOD STRUCTURAL PANEL SHEAR WALLS AND DIAPHRAGMS
SECTION 2306 ALLOWABLE STRESS DESIGN
529 TABLE 2306.1.4 ALLOWABLE LOADS FOR LUMBER DECKING
530 SECTION 2307 LOAD AND RESISTANCE FACTOR DESIGN
SECTION 2308 CONVENTIONAL LIGHT-FRAME CONSTRUCTION
TABLE 2308.2.1 ALLOWABLE STORY HEIGHT
531 TABLE 2306.2(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH, OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGf
532 TABLE 2306.2(2) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, g, h
533 TABLE 2306.2(2)—continued ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL BLOCKED DIAPHRAGMS UTILIZING MULTIPLE ROWS OF STAPLES (HIGH-LOAD DIAPHRAGMS) WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINE FOR WIND OR SEISMIC LOADING
534 TABLE 2306.3(1) ALLOWABLE SHEAR VALUES (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL SHEAR WALLS UTILIZING STAPLES WITH FRAMING OF DOUGLAS FIR-LARCH OR SOUTHERN PINEa FOR WIND OR SEISMIC LOADINGb, f, g, i
TABLE 2306.3(2) ALLOWABLE SHEAR VALUES (plf) FOR WIND OR SEISMIC LOADING ON SHEAR WALLS OF FIBERBOARD SHEATHING BOARD CONSTRUCTION UTILIZING STAPLES FOR TYPE V CONSTRUCTION ONLYa, b, c, d, e
535 TABLE 2306.3(3) ALLOWABLE SHEAR VALUES FOR WIND OR SEISMIC FORCES FOR SHEAR WALLS OF LATH AND PLASTER OR GYPSUM BOARD WOOD FRAMED WALL ASSEMBLIES UTILIZING STAPLES
537 TABLE 2308.4.1.1(1) HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
538 TABLE 2308.4.1.1(1)—continued HEADER AND GIRDER SPANSa, b FOR EXTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-firb and required number of jack studs)
539 TABLE 2308.4.1.1(2) HEADER AND GIRDER SPANSa, b FOR INTERIOR BEARING WALLS (Maximum spans for Douglas fir-larch, hem-fir, Southern pine and spruce-pine-fir and required number of jack studs)
540 TABLE 2308.4.2.1(1) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
541 TABLE 2308.4.2.1(1)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential sleeping areas, live load = 30 psf, L/Δ = 360)
542 TABLE 2308.4.2.1(2) FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
543 TABLE 2308.4.2.1(2)—continued FLOOR JOIST SPANS FOR COMMON LUMBER SPECIES (Residential living areas, live load = 40 psf, L/Δ = 360)
544 FIGURE 2308.4.4.1(1) OPENINGS IN FLOOR AND ROOF DIAPHRAGMS
545 FIGURE 2308.4.4.1(2) OPENING LIMITATIONS FOR FLOOR AND ROOF DIAPHRAGMS
FIGURE 2308.4.4.2 PORTIONS OF FLOOR LEVEL OFFSET VERTICALLY
TABLE 2308.5.1 SIZE, HEIGHT AND SPACING OF WOOD STUDSc
547 FIGURE 2308.5.5.1(1) SINGLE-MEMBER HEADER IN EXTERIOR BEARING WALL
FIGURE 2308.5.5.1(2) ALTERNATIVE SINGLE-MEMBER HEADER WITHOUT CRIPPLE
548 TABLE 2308.5.11 MINIMUM THICKNESS OF WALL SHEATHING
549 FIGURE 2308.6.1 BASIC COMPONENTS OF THE LATERAL BRACING SYSTEM
550 TABLE 2308.6.1a WALL BRACING REQUIREMENTS
551 TABLE 2308.6.3(1) BRACING METHODS
552 TABLE 2308.6.3(1)—continued BRACING METHODS
TABLE 2308.6.3(2) EXPOSED PLYWOOD PANEL SIDING
553 TABLE 2308.6.3(3) WOOD STRUCTURAL PANEL WALL SHEATHINGb (Not exposed to the weather, strength axis parallel or perpendicular to studs except as Indicated)
TABLE 2308.6.3(4) ALLOWABLE SPANS FOR PARTICLEBOARD WALL SHEATHING (Not exposed to the weather, long dimension of the panel parallel or perpendicular to studs)
TABLE 2308.6.3(5) HARDBOARD SIDING
554 FIGURE 2308.6.5.1 ALTERNATE BRACED WALL PANEL (ABW)
FIGURE 2308.6.5.2 PORTAL FRAME WITH HOLD-DOWNS (PFH)
556 FIGURE 2308.6.7.2(1) BRACED WALL LINE TOP PLATE CONNECTION
FIGURE 2308.6.7.2(2) BRACED WALL PANEL TOP PLATE CONNECTION
558 FIGURE 2308.6.8.2(1) ROOF IN SDC D OR E NOT SUPPORTED ON ALL EDGES
FIGURE 2308.6.8.2(2) ROOF EXTENSION IN SDC D OR E BEYOND BRACED WALL LINE
559 FIGURE 2308.6.8.3 STEPPED FOOTING CONNECTION DETAILS
560 TABLE 2308.7.5 REQUIRED RATING OF APPROVED UPLIFT CONNECTORS (pounds)a, b, c, e, f, g, h
561 SECTION 2309 WOOD FRAME CONSTRUCTION MANUAL
562 TABLE 2308.7.1(1) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
563 TABLE 2308.7.1(1)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics without storage, live load = 10 psf, L/Δ = 240)
564 TABLE 2308.7.1(2) CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
565 TABLE 2308.7.1(2)—continued CEILING JOIST SPANS FOR COMMON LUMBER SPECIES (Uninhabitable attics with limited storage, live load = 20 psf, L/Δ = 240)
566 TABLE 2308.7.2(1) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
567 TABLE 2308.7.2(1)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling not attached to rafters, L/Δ = 180)
568 TABLE 2308.7.2(2) RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
569 TABLE 2308.7.2(2)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Roof live load = 20 psf, ceiling attached to rafters, L/Δ = 240)
570 TABLE 2308.7.2(3) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
571 TABLE 2308.7.2(3)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling not attached to rafters, L/Δ = 180)
572 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
573 TABLE 2308.7.2(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, L/Δ = 180)
574 TABLE 2308.7.2(5) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
575 TABLE 2308.7.2(5)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 30 psf, ceiling attached to rafters, L/Δ = 240)
576 TABLE 2308.7.2(6) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
577 TABLE 2308.7.2(6)—continued RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling attached to rafters, L/Δ = 240)
578 TABLE 2308.7.3.1 RAFTER TIE CONNECTIONSg
579 TABLE 2308.7.12 ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
580 TABLE 2308.7.12—continued ALLOWABLE SPANS FOR 2-INCH TONGUE-AND-GROOVE DECKING
582 CHAPTER 24 GLASS AND GLAZING
SECTION 2401 GENERAL
SECTION 2402 GLAZING REPLACEMENT
SECTION 2403 GENERAL REQUIREMENTS FOR GLASS
SECTION 2404 WIND, SNOW, SEISMIC AND DEAD LOADS ON GLASS
583 EQUATION 24-1
EQUATION 24-2
EQUATION 24-3
EQUATION 24-4
EQUATION 24-5
EQUATION 24-6
EQUATION 24-7
EQUATION 24-8
EQUATION 24-9
EQUATION 24-10
EQUATION 24-11
584 EQUATION 24-12
SECTION 2405 SLOPED GLAZING AND SKYLIGHTS
585 EQUATION 24-13
EQUATION 24-14
EQUATION 24-15
SECTION 2406 SAFETY GLAZING
586 TABLE 2406.2(1) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING CPSC 16 CFR PART 1201
TABLE 2406.2(2) MINIMUM CATEGORY CLASSIFICATION OF GLAZING USING ANSI Z97.1
587 SECTION 2407 GLASS IN HANDRAILS AND GUARDS
SECTION 2408 GLAZING IN ATHLETIC FACILITIES
588 SECTION 2409 GLASS IN WALKWAYS, ELEVATOR HOISTWAYS AND ELEVATOR CARS
590 CHAPTER 25 GYPSUM BOARD, GYPSUM PANEL PRODUCTS AND PLASTER
SECTION 2501 GENERAL
SECTION 2502 PERFORMANCE
SECTION 2503 INSPECTION
SECTION 2504 VERTICAL AND HORIZONTAL ASSEMBLIES
SECTION 2505 SHEAR WALL CONSTRUCTION
SECTION 2506 GYPSUM BOARD AND GYPSUM PANEL PRODUCT MATERIALS
591 TABLE 2506.2 GYPSUM BOARD AND GYPSUM PANEL PRODUCTS MATERIALS AND ACCESSORIES
SECTION 2507 LATHING AND PLASTERING
SECTION 2508 GYPSUM CONSTRUCTION
TABLE 2508.1 INSTALLATION OF GYPSUM CONSTRUCTION
592 TABLE 2507.2 LATH, PLASTERING MATERIALS AND ACCESSORIES
593 TABLE 2508.6 SHEAR CAPACITY FOR HORIZONTAL WOOD-FRAME GYPSUM BOARD DIAPHRAGM CEILING ASSEMBLIES
SECTION 2509 SHOWERS AND WATER CLOSETS
TABLE 2509.2 BACKERBOARD MATERIALS
SECTION 2510 LATHING AND FURRING FOR CEMENT PLASTER (STUCCO)
594 SECTION 2511 INTERIOR PLASTER
TABLE 2511.1.1 INSTALLATION OF PLASTER CONSTRUCTION
SECTION 2512 EXTERIOR PLASTER
595 TABLE 2512.6 CEMENT PLASTERS
SECTION 2513 EXPOSED AGGREGATE PLASTER
SECTION 2514 REINFORCED GYPSUM CONCRETE
596 CHAPTER 26 PLASTIC
SECTION 2601 GENERAL
SECTION 2602 FINISH AND TRIM
SECTION 2603 FOAM PLASTIC INSULATION
599 FIGURE 2603.8 TERMITE INFESTATION PROBABILITY MAP
601 TABLE 2603.12.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
TABLE 2603.12.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
602 TABLE 2603.13.1 CLADDING MINIMUM FASTENING REQUIREMENTS FOR DIRECT ATTACHMENT OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa
SECTION 2604 INTERIOR FINISH AND TRIM
SECTION 2605 PLASTIC VENEER
603 TABLE 2603.13.2 FURRING MINIMUM FASTENING REQUIREMENTS FOR APPLICATION OVER FOAM PLASTIC SHEATHING TO SUPPORT CLADDING WEIGHTa, b
SECTION 2606 LIGHT-TRANSMITTING PLASTICS
604 SECTION 2607 LIGHT-TRANSMITTING PLASTIC WALL PANELS
605 TABLE 2607.4 AREA LIMITATION AND SEPARATION REQUIREMENTS FOR LIGHT-TRANSMITTING PLASTIC WALL PANELSa
SECTION 2608 LIGHT-TRANSMITTING PLASTIC GLAZING
SECTION 2609 LIGHT-TRANSMITTING PLASTIC ROOF PANELS
606 TABLE 2609.4 AREA LIMITATIONS FOR LIGHT-TRANSMITTING PLASTIC ROOF PANELS
SECTION 2610 LIGHT-TRANSMITTING PLASTIC SKYLIGHT GLAZING
607 SECTION 2611 LIGHT-TRANSMITTING PLASTIC INTERIOR SIGNS
SECTION 2612 PLASTIC COMPOSITES
SECTION 2613 FIBER-REINFORCED POLYMER
608 SECTION 2614 REFLECTIVE PLASTIC CORE INSULATION
610 CHAPTER 27 ELECTRICAL
SECTION 2701 GENERAL
SECTION 2702 EMERGENCY AND STANDBY POWER SYSTEMS
612 CHAPTER 28 MECHANICAL SYSTEMS
SECTION 2801 GENERAL
614 CHAPTER 29 PLUMBING SYSTEMS
SECTION 2901 GENERAL
SECTION 2902 MINIMUM PLUMBING FACILITIES
[P] TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
615 [P] TABLE 2902.1—(continued) MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
616 [P] TABLE 2902.1—continued MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURESa (See Sections 2902.1.1 and 2902.2)
618 CHAPTER 30 ELEVATORS AND CONVEYING SYSTEMS
SECTION 3001 GENERAL
TABLE 3001.3 ELEVATORS AND CONVEYING SYSTEMS AND COMPONENTS
SECTION 3002 HOISTWAY ENCLOSURES
619 SECTION 3003 EMERGENCY OPERATIONS
SECTION 3004 CONVEYING SYSTEMS
620 SECTION 3005 MACHINE ROOMS
SECTION 3006 ELEVATOR LOBBIES AND HOISTWAY OPENING PROTECTION
621 SECTION 3007 FIRE SERVICE ACCESS ELEVATOR
622 FIGURE 3007.6.5 FIRE SERVICE ACCESS ELEVATOR SYMBOL
SECTION 3008 OCCUPANT EVACUATION ELEVATORS
626 CHAPTER 31 SPECIAL CONSTRUCTION
SECTION 3101 GENERAL
SECTION 3102 MEMBRANE STRUCTURES
627 SECTION 3103 TEMPORARY STRUCTURES
SECTION 3104 PEDESTRIAN WALKWAYS AND TUNNELS
629 SECTION 3105 AWNINGS AND CANOPIES
SECTION 3106 MARQUEES
SECTION 3107 SIGNS
SECTION 3108 TELECOMMUNICATION AND BROADCAST TOWERS
630 SECTION 3109 SWIMMING POOLS, SPAS AND HOT TUBS
SECTION 3110 AUTOMATIC VEHICULAR GATES
SECTION 3111 SOLAR ENERGY SYSTEMS
SECTION 3112 GREENHOUSES
SECTION 3113 RELOCATABLE BUILDINGS
632 CHAPTER 32 ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
SECTION 3201 GENERAL
SECTION 3202 ENCROACHMENTS
634 CHAPTER 33 SAFEGUARDS DURING CONSTRUCTION
SECTION 3301 GENERAL
SECTION 3302 CONSTRUCTION SAFEGUARDS
SECTION 3303 DEMOLITION
SECTION 3304 SITE WORK
635 SECTION 3305 SANITARY
SECTION 3306 PROTECTION OF PEDESTRIANS
TABLE 3306.1 PROTECTION OF PEDESTRIANS
636 SECTION 3307 PROTECTION OF ADJOINING PROPERTY
SECTION 3308 TEMPORARY USE OF STREETS, ALLEYS AND PUBLIC PROPERTY
SECTION 3309 FIRE EXTINGUISHERS
SECTION 3310 MEANS OF EGRESS
637 SECTION 3311 STANDPIPES
SECTION 3312 AUTOMATIC SPRINKLER SYSTEM
SECTION 3313 WATER SUPPLY FOR FIRE PROTECTION
SECTION 3314 FIRE WATCH DURING CONSTRUCTON
638 CHAPTER 34 RESERVED
640 CHAPTER 35 REFERENCED STANDARDS
AA
AAMA
ACI
AISC
641 AISI
ALI
AMCA
ANSI
642 APA
643 ASABE
ASCE/SEI
644 ASME
ASSE
ASTM
655 AWC
AWCI
656 AWPA
AWS
BHMA
CEN
CPA
657 CPSC
CSA
CSSB
DASMA
658 DOC
DOL
DOTn
FEMA
FM
659 GA
HPVA
ICC
660 ISO
661 MHI
NAAMM
NCMA
NFPA
664 PCI
PTI
RMI
SBCA
SDI
SJI
665 SPRI
SRCC
TIA
TMS
TPI
666 UL
668 ULC
USC
WCLIB
WDMA
WRI
670 APPENDIX A EMPLOYEE QUALIFICATIONS
SECTION A101 BUILDING OFFICIAL QUALIFICATIONS
[A] SECTION A102 REFERENCED STANDARDS
672 APPENDIX B BOARD OF APPEALS
SECTION B101 GENERAL
674 APPENDIX C GROUP U—AGRICULTURAL BUILDINGS
SECTION C101 GENERAL
SECTION C102 ALLOWABLE HEIGHT AND AREA
TABLE C102.1 BASIC ALLOWABLE AREA FOR A GROUP U, ONE STORY IN HEIGHT AND MAXIMUM HEIGHT OF SUCH OCCUPANCY
SECTION C103 MIXED OCCUPANCIES
SECTION C104 EXITS
676 APPENDIX D FIRE DISTRICTS
SECTION D101 GENERAL
SECTION D102 BUILDING RESTRICTIONS
677 SECTION D103 CHANGES TO BUILDINGS
SECTION D104 BUILDINGS LOCATED PARTIALLY IN THE FIRE DISTRICT
SECTION D105 EXCEPTIONS TO RESTRICTIONS IN FIRE DISTRICT
678 SECTION D106 REFERENCED STANDARDS
680 APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS
SECTION E101 GENERAL
SECTION E102 DEFINITIONS
SECTION E103 ACCESSIBLE ROUTE
SECTION E104 SPECIAL OCCUPANCIES
681 TABLE E104.2.1 DWELLING OR SLEEPING UNITS WITH ACCESSIBLE COMMUNICATION FEATURES
SECTION E105 OTHER FEATURES AND FACILITIES
SECTION E106 TELEPHONES
TABLE E106.2 WHEELCHAIR-ACCESSIBLE TELEPHONES
682 SECTION E107 SIGNAGE
SECTION E108 BUS STOPS
683 SECTION E109 TRANSPORTATION FACILITIES AND STATIONS
684 SECTION E110 AIRPORTS
SECTION E111 REFERENCED STANDARDS
686 APPENDIX F RODENTPROOFING
SECTION F101 GENERAL
688 APPENDIX G FLOOD-RESISTANT CONSTRUCTION
SECTION G101 ADMINISTRATION
SECTION G102 APPLICABILITY
SECTION G103 POWERS AND DUTIES
689 SECTION G104 PERMITS
690 SECTION G105 VARIANCES
691 SECTION G201 DEFINITIONS
SECTION G301 SUBDIVISIONS
SECTION G401 SITE IMPROVEMENT
692 SECTION G501 MANUFACTURED HOMES
SECTION G601 RECREATIONAL VEHICLES
SECTION G701 TANKS
SECTION G801 OTHER BUILDING WORK
693 SECTION G901 TEMPORARY STRUCTURES AND TEMPORARY STORAGE
SECTION G1001 UTILITY AND MISCELLANEOUS GROUP U
SECTION G1101 REFERENCED STANDARDS
694 APPENDIX H SIGNS
SECTION H101 GENERAL
SECTION H102 DEFINITIONS
SECTION H103 LOCATION
695 SECTION H104 IDENTIFICATION
SECTION H105 DESIGN AND CONSTRUCTION
SECTION H106 ELECTRICAL
SECTION H107 COMBUSTIBLE MATERIALS
SECTION H108 ANIMATED DEVICES
696 SECTION H109 GROUND SIGNS
SECTION H110 ROOF SIGNS
SECTION H111 WALL SIGNS
SECTION H112 PROJECTING SIGNS
697 SECTION H113 MARQUEE SIGNS
SECTION H114 PORTABLE SIGNS
TABLE 4-A SIZE, THICKNESS AND TYPE OF GLASS PANELS IN SIGNS
TABLE 4-B THICKNESS OF PROJECTION SIGN
SECTION H115 REFERENCED STANDARDS
698 APPENDIX I PATIO COVERS
SECTION I101 GENERAL
SECTION I102 DEFINITION
SECTION I103 EXTERIOR WALLS AND OPENINGS
SECTION I104 HEIGHT
SECTION I105 STRUCTURAL PROVISIONS
700 APPENDIX J GRADING
SECTION J101 GENERAL
SECTION J102 DEFINITIONS
SECTION J103 PERMITS REQUIRED
701 SECTION J104 PERMIT APPLICATION AND SUBMITTALS
SECTION J105 INSPECTIONS
SECTION J106 EXCAVATIONS
SECTION J107 FILLS
SECTION J108 SETBACKS
702 FIGURE J107.3 BENCHING DETAILS
FIGURE J108.1 DRAINAGE DIMENSIONS
703 SECTION J109 DRAINAGE AND TERRACING
SECTION J110 EROSION CONTROL
SECTION J111 REFERENCED STANDARDS
704 APPENDIX K ADMINISTRATIVE PROVISIONS
SECTION K101 GENERAL
SECTION K102 APPLICABILITY
SECTION K103 PERMITS
705 SECTION K104 CONSTRUCTION DOCUMENTS
SECTION K105 ALTERNATIVE ENGINEERED DESIGN
SECTION K106 REQUIRED INSPECTIONS
SECTION K107 PREFABRICATED CONSTRUCTION
706 SECTION K108 TESTING
SECTION K109 RECONNECTION
SECTION K110 CONDEMNING ELECTRICAL SYSTEMS
SECTION K111 ELECTRICAL PROVISIONS
708 APPENDIX L EARTHQUAKE RECORDING INSTRUMENTATION
SECTION L101 GENERAL
710 APPENDIX M TSUNAMI-GENERATED FLOOD HAZARD
SECTION M101 REFUGE STRUCTURES FOR VERTICAL EVACUATION FROM TSUNAMI-GENERATED FLOOD HAZARD
SECTION M102 REFERENCED STANDARDS
712 APPENDIX N REPLICABLE BUILDINGS
SECTION N101 ADMINISTRATION
SECTION N102 DEFINITIONS
SECTION N103 REPLICABLE DESIGN REQUIREMENTS
SECTION N104 REPLICABLE DESIGN SUBMITTAL REQUIREMENTS
713 SECTION N105 REVIEW AND APPROVAL OF REPLICABLE DESIGN
SECTION N106 SITE-SPECIFIC APPLICATION OF APPROVED REPLICABLE DESIGN
SECTION N107 SITE-SPECIFIC REVIEW AND APPROVAL OF REPLICABLE DESIGN
714 INDEX
754 ICC MEMBERSHIP – BENEFITS THAT WORK FOR YOU
755 ICC EVALUATION SERVICE
756 GET IMMEDIATE DOWNLOADS OF THE STANDARDS YOU NEED
757 VALUABLE GUIDES TO CHANGES IN THE 2018 I-CODES®
ICC IBC 2018
$72.50